TurboChill & TurboChill FreeCool
|
|
|
- Griffin Garrett
- 10 years ago
- Views:
Transcription
1 Chiller Air cooled / Free-cooling WINNER Energy Saving Product of the Year. TurboChill & TurboChill FreeCool kW + ESEER up to Class A EER up to kW air cooled models kW FreeCool models HFC R134a HFC R134a HFO R1234ze HFO R1234ze CENTRIFUGAL COMPRESSOR MICRO MICROCHANNEL COIL FREE COOL FREE-COOLING EC EC FAN BRITISH MANUFACTURER ENERGY EFFICIENCY CONTROLS SERVICE TRAINING
2 01 Unparalleled efficiency Ultimate in advanced chiller technology The TurboChill TM is a high-capacity, air-cooled, single/dual circuit chiller, which offers exceptional ESEER values of up to With an extensive cooling capacity of up to 1830kW, the TurboChill TM range has been engineered using the very best chiller technology and components to increase effi ciency and deliver improved performance. Increased flexibility and choice The TurboChill TM offers increased fl exibility and choice with more than 230 models available to choose from. 76 of these models have been specifi cally developed for use with the low Global Warming Potential (GWP) refrigerant R1234ze, whilst 110 TurboChill TM models from the range combine the latest compressor technology with the power-saving benefi ts of freecooling. Microchannel heat exchanger* Centrifugal compressor Flooded evaporator EC fans Modular V-frame High surface area provides increased heat transfer and lower airside pressure drop giving lower fan powers; the slim, light profi le reduces weight / space claim % variable speed control for tighter setpoint management and substantial energy savings at part load Enhanced optimum heat exchange and system effi ciency give 15% energy savings in compressor operation particularly at part load Electronically commutated axial fans give increased performance for reduced power input* * than an AC fan at part load Vastly improves heat exchange, resulting in better performance and control particularly at part load; also facilitates easier maintenance * polymer-coated as standard for longevity Carbon Trust Enhanced Capital Allowance Scheme All models in the TurboChill TM range meet the criteria set out by the Energy Technology List and are currently pending accreditation. Inclusion on the ETL list offers the potential for investors to claim 100% fi rst year capital allowance. For details see
3 02 Class A EER up to 4.35 Velocity (m/s) 12 Energy Efficiency Ratio at 7/12 C water and 35 C ambient. CFD analysis was used to determine the optimum fan and heat exchanger size and the best distribution and total air fl ow through the unit Modular V-frame coil design The Turbochill TM range utilises an innovative V-frame coil confi guration, which maximises the heat exchange area, therefore improving system performance and control. The unique coil arrangement offers high coil face area and enables best air fl ow distribution to minimise power consumption. Microchannel heat exchangers Low GWP refrigerants R1234ze signifi cantly reduces environmental impact and has a low global warming potential (GWP) of under one*. This means that the time taken for the refrigerant to break down and for it to be absorbed into the atmosphere is minimised. Therefore, the lifespan of the refrigerant R1234ze is just 16 days. *As rated by the International Panel for Climate Change (IPCC). The large surface areas of the microchannel heat exchangers enable cooling capacities to be extended and lower condensing temperatures to be achieved within a smaller footprint. The microchannel heat exchangers offer increased heat transfer and further improve effi ciency by reducing air-side pressure drop, allowing increased air fl ow to pass through the coil. This increases the total heat rejection and fan effi ciency at both full and part load. Up to 20% energy savings The latest EC fan technology is used within the TurboChill TM range to provide even greater control, increase effi ciency and minimise noise. EC fans offer a lightweight, rigid alternative to conventional fans. The fan housing is also up to 8kg lighter, helping to improve fan performance. EC fans provide variable speed control which matches to load requirements and lowers air fl ow resistance, therefore reducing power input and energy consumption.
4 03 Next generation Oil-free compressor technology The TurboChill TM range utilises oil-free centrifugal compressors (TT300, TT350 / R134a) and the new TG310 compressors, which operate using the next generation low, global warming potential refrigerant R1234ze. These intelligent, self-optimising compressors enable variable speed control and minimise input power with near silent operation. Magnetic bearings within the centrifugal compressor levitate the compressor shaft and with no mechanical contact or friction between mating surfaces, the need for lubrication is eliminated. Efficient flooded evaporator The fl ooded evaporator results in 15% energy savings in compressor operation particularly at part load. The compressor runs at 20 C condensing temperature when evaporating at 5 C, as opposed to around 35ºC condensing for a conventional screw compressor. The addition of an integral heat exchanger within the evaporator extends cooling capacity and increases the effi ciency of the system whilst keeping the evaporator footprint to a minimum. Image shown: TG310 Compressor Excellent reliability: No operational wear and tear With virtually no vibration and fewer moving parts within the compressor, there is no operational wear and tear. Costly bearing replacement is therefore avoided and equipment life extended. In the event of a power failure, the compressor acts as a generator and powers itself down in a controlled manner. 13 C B CHILLER START Exact capacity match 7 C A y axis: WATER TEMP x axis: TIME % modulating TurboChill vs. staged screw chiller TurboChill modulating supply water temperature Conventional screw chiller water temperature Step control conventional screw chiller - 4 stages of cooling Variable speed compressor control ranging from %, allows the TurboChill to save substantial amounts of energy when operating at part load. Variable speed control facilitates accurate supply water set point control. It enables the TurboChill to react to system load fl uctuations and exactly match cooling demand. A = Supply temperature setpoint B = Actual water temperature
5 04 Brilliantly engineered For enhanced performance and increased reliability Running Cost = 54,833 Running Cost = 44, Leading competitor inverter screw chiller vs. 50% load Leading competitor Airedale x axis: Ambient Temperature C y axis: kwh Save up to 23% in operating costs p.a Running costs signifi cantly reduced by up to 23% p.a*, when operating at part load. *compared with the leading competitor screw chiller over an annual cycle in Leeds, UK Low current start By removing the transient starting spikes normally associated with screw chillers of this capacity, electrical supply components need not be oversized on site. Conventional screw fuse size - 225A EER over 15.0 at part load EER increase of over 22% Integral low current start (2A) Centrifugal compressor Conventional screw Centrifugal compressor fuse size - 150A For a typical 300kw compressor. Based on a 400V/3PH/50Hz supply Running Current Leading competitor screw chiller vs. 50% load Leading competitor Airedale Ambient Hours Leeds x axis: Ambient Temperature C y axis 1: EER y axis 2: Ambient Hours
6 05 Free-cooling For over 95% of the year Free-cooling saves vast amounts of energy, particularly when room temperatures are high. For free-cooling operation, the temperature difference between the ambient air and the return water can be as little as 1 C. The TurboChill TM FreeCool range offers concurrent free-cooling for up to 95% of the year (cumulative hours, London, UK). For up to 30% of the year, the TurboChill TM FreeCool can operate in freecooling mode only. One kilowatt of power saved every hour 24/7, represents a saving of 876* a year, equivalent to over 4 tonnes of CO 2. * 0.10kW/h BREEAM BREEAM aims to reduce the life cycle impact of new buildings on the environment by awarding points for products used within the building s design which minimise the building s carbon footprint. The TurboChill TM range contributes to a building potentially achieving an additional two BREEAM points. Points can be achieved in the following ways: 1. TurboChill TM models which use the new R1234ze refrigerant automatically receive two BREEAM points as the refrigerant has a global warming potential of less than one. 2. TurboChill TM models which feature the refrigerant R134a qualify for one BREEAM point automatically. They can also receive a further BREEAM point if the leak detection* and refrigerant pump down option is selected. * Leak detection as standard for R1234ze models
7 06 Intelligent controls Seamlessly managing your system The control centre of each of our cooling systems is a sophisticated electronic microprocessor specially developed by Airedale. The intelligent microprocessor uses sensors which allow active components to interact. By integrating and sequencing components, the controller manages and optimises the system s performance, availability and power draw, giving the operator complete system control. Generator/ UPS/Server Building lighting Energy Manager Sequencer Fully-programmable via the control panel s user-friendly display, the microprocessor can be linked with all standard BMS protocols to: ACIS C Trigger alarm messages Send alarm/service messages via or SMS using an interface Operate time scheduling Allow adjustment of temperature setpoints ACIS is a building management system developed by Airedale, which enables smart cooling and other building services, from any manufacturer, to be managed through a single, integrated solution across multiple sites and communication protocols. ACIS sits at the front end of a building management system and puts the operator in full control of reducing building operating costs. Through the click of a button on a PC, tablet or phone, intelligent information can be retrieved automatically allowing informed, data driven decisions to be made. With 24/7 access, ACIS provides an ideal solution for remote monitoring and maintenance, including live PUE, EER and COP calculations and power distribution monitoring.
8 07 Specifications at a glance The ultra-efficient, variable speed control of the TurboChill allows it to match load requirements exactly and enables selection of the optimum model, in terms of efficiency, sound level, footprint and price, for each individual application. Environment Mechanical TurboChill range available with R134a refrigerant and the new low GWP refrigerant R1234ze R134a Single circuit kW (TCC), kW (TCF) / Dual circuit kW (TCC), kW (TCF) Refrigerant isolation actuators as standard to contain refrigerant in the event of a leak (R1234ze models only / optional for R134a models) R1234ze Single circuit kW (TCC), kW (TCF) / Dual circuit kW (TCC), kW (TCF) Free-cooling at up to 116% of nominal capacity for reduced operating costs and carbon footprint (TCF) 236 models, 150 of which are dual circuit models TurbochillTM range offers 110 free-cooling variants High supply water temperature capability; up to 18 C Operation up to 35ºC ambient at full load, 40ºC at reduced load Centrifugal compressor technology offers near silent compressor operation TT300, TT350 and TG310 fully modulating compressors Low sound ranges: Regular Quiet (R) and Extra Quiet (X) Flooded evaporator improves part load efficiencies Latest axial fan technology for reduced sound and power input Liquid level sensor to control liquid within the evaporator Polymer-coated microchannel coils for reduced life cycle costs and reduced footprint Modular V frame coil arrangement offers increased heat exchange area and improved air flow for increased efficiency Compressor acoustic enclosures minimising sound emission TM Leak detection system for F Gas compliance (standard for R1234ze models) Automatic refrigerant pump down in the event of a refrigerant leak, which together with leak detection, qualifies the TurboChill for one additional BREEAM point (standard for R1234ze models) Extended plenum to minimise sound Anti-vibration mounts reduce sound levels transmitted to building EC fans provide increased airflow, reduced noise and greater efficiencies Variable speed for super efficiency, tighter set point control and exact capacity match In-built low current start (2A) Oil-free operation enhances heat exchanger efficiency Up to two compressors across a single circuit for reduced energy consumption at part load Automatic rescheduling of chilled water setpoint Head pressure set point management achieving optimum EER Optional High airflow EC fan available Additional redundancy back-up and quicker compressor start up to full load capacity on dual circuit models Variable supply water temperature control to save power and raise the free-cooling threshold Filter drier, sight glass and liquid, discharge and suction ball valves allowing each compressor to be individually isolated Chiller Sequence Manager integrates 2 to 6 chillers into a single, efficient operating system Easy access to components for maintenance Energy Manager is a compact, spacesaving analyser which enables monitoring of the TurboChill s energy consumption locally and remotely via BMS connections Condensers can be isolated, facilitating maintenance Economiser circuit for increased capacity and efficiency (R134a models only) Optional Energy-saving Optional Rain hood available Choice of refrigerant R134a or R1234ze (model dependent) Corrosion-resistant condenser coils for corrosive atmospheres (option for FC models, standard otherwise) Actuated suction ball valves (R134a models only)
9 08 Hydronics Electronics & controls Differential pressure transducer to indicate water flow Advanced controls technology to manage and optimise performance Grooved water connections for simple installation Electrical supply phase loss and rotation protection Accessible control panel, even when unit is operational Single point of isolation for ease of maintenance Control panel mounted isolator for single phase permanent power supply Control panel lighting for maintenance in low light conditions Panel thermostatically controlled ventilation and heating Individual mains isolators for fans and optional pump(s) Ultracap power backup for the controllers and valve drivers Optional Latest technology end suction pumps offer excellent flow rate control whilst having low vibrational characteristics Selection of hydronic options available include extended pipework; bypass or no bypass; single pump and run and standby (selected models only) Inverter-driven pumps enabling exact water flow control for the application Regulating or flushing bypass for enhanced resilience and maintenance Flow switch for flow rate detection Water filter safeguarding performance (standard on TCF) No. of fans Height (mm) Width (mm) Length (mm) Height Width Length
10 09 TurboChill technical specifications (R134a) Model no. Nominal cooling EER ESEER Free-Cooling Free-Cooling EER Sound 10m (dba) Dimensions (H x W x L)(mm) Regular Quiet - Single Circuit - Air Cooled TCC11R04S x x 2626 TCC11R06S x x 3758 TCC11R08S x x 4890 TCC11R06L x x 3758 TCC11R08L x x 4890 TCC11R10L x x 6022 TCC12R08S x x 4890 TCC12R10S x x 6022 TCC12R12S x x 7154 TCC12R14S x x 8286 TCC12R10L x x 6022 TCC12R12L x x 7154 TCC12R14L x x 8286 TCC12R16L x x 9418 TCC12R18L x x TCC12R20L x x Regular Quiet - Dual Circuit - Air Cooled TCC22R08S x x 4890 TCC22R10S x x 6022 TCC22R12S x x 7154 TCC22R14S x x 8286 TCC22R10L x x 6022 TCC22R12L x x 7154 TCC22R14L x x 8286 TCC22R16L x x 9418 TCC22R18L x x TCC22R20L x x TCC23R12S x x 7154 TCC23R14S x x 8286 TCC23R16S x x 9418 TCC23R18S x x TCC23R16L x x 9418 TCC23R18L x x TCC23R20L x x TCC23R22L x x TCC23R24L x x TCC24R16S x x 9418 TCC24R18S x x TCC24R20S x x TCC24R22S x x TCC24R24S x x TCC24R20L x x TCC24R22L x x TCC24R24L x x Extra Quiet - Single Circuit - Air Cooled TCC11X04S x x 2626 TCC11X06S x x 3758 TCC11X08S x x 4890 TCC11X06L x x 3758 TCC11X08L x x 4890 TCC11X10L x x 6022 TCC12X08S x x 4890 TCC12X10S x x 6022 TCC12X12S x x 7154 TCC12X14S x x 8286 TCC12X10L x x 6022 TCC12X12L x x 7154 TCC12X14L x x 8286 TCC12X16L x x 9418 TCC12X18L x x TCC12X20L x x Extra Quiet - Dual Circuit - Air Cooled TCC22X08S x x 4890 TCC22X10S x x 6022 TCC22X12S x x 7154 TCC22X14S x x 8286 TCC22X10L x x 6022 TCC22X12L x x 7154 TCC22X14L x x 8286 TCC22X16L x x 9418 TCC22X18L x x TCC22X20L x x 11682
11 10 TurboChill technical specifications (R134a) Continued Model no. Nominal cooling EER ESEER Free-Cooling Free-Cooling EER Sound 10m (dba) Dimensions (H x W x L)(mm) Extra Quiet - Dual Circuit - Air Cooled (continued) TCC23X12S x x 7154 TCC23X14S x x 8286 TCC23X16S x x 9418 TCC23X18S x x TCC23X16L x x 9418 TCC23X18L x x TCC23X20L x x TCC23X22L x x TCC23X24L x x TCC24X16S x x 9418 TCC24X18S x x TCC24X20S x x TCC24X22S x x TCC24X24S x x TCC24X20L x x TCC24X22L x x TCC24X24L x x Regular Quiet - Single Circuit - FreeCool TCF11R06S x x 3758 TCF11R08S x x 4890 TCF11R06L x x 3758 TCF11R08L x x 4890 TCF11R10L x x 6022 TCF12R08S x x 4890 TCF12R10S x x 6022 TCF12R12S x x 7154 TCF12R14S x x 8286 TCF12R12L x x 7154 TCF12R14L x x 8286 TCF12R16L x x 9418 TCF12R18L x x TCF12R20L x x Regular Quiet - Dual Circuit - FreeCool TCF22R10S x x 6022 TCF22R12S x x 7154 TCF22R14S x x 8286 TCF22R12L x x 7154 TCF22R14L x x 8286 TCF22R16L x x 9418 TCF22R18L x x TCF22R20L x x TCF23R12S x x 7154 TCF23R14S x x 8286 TCF23R16S x x 9418 TCF23R18S x x TCF23R18L x x TCF23R20L x x TCF23R22L x x TCF23R24L x x TCF24R16S x x 9418 TCF24R18S x x TCF24R20S x x TCF24R22S x x TCF24R24S x x TCF24R22L x x TCF24R24L x x Extra Quiet - Single Circuit - FreeCool TCF11X06S x x 3758 TCF11X08S x x 4890 TCF11X06L x x 3758 TCF11X08L x x 4890 TCF11X10L x x 6022 TCF12X08S x x 4890 TCF12X10S x x 6022 TCF12X12S x x 7154 TCF12X14S x x 8286 TCF12X12L x x 7154 TCF12X14L x x 8286 TCF12X16L x x 9418 TCF12X18L x x TCF12X20L x x 11682
12 11 TurboChill technical specifications (R134a) Continued Model no. Nominal cooling EER ESEER Free-Cooling Free-Cooling EER Sound 10m (dba) Dimensions (H x W x L)(mm) Extra Quiet - Dual Circuit - FreeCool (continued) TCF22X10S x x 6022 TCF22X12S x x 7154 TCF22X14S x x 8286 TCF22X12L x x 7154 TCF22X14L x x 8286 TCF22X16L x x 9418 TCF22X18L x x TCF22X20L x x TCF23X12S x x 7154 TCF23X14S x x 8286 TCF23X16S x x 9418 TCF23X18S x x TCF23X18L x x TCF23X20L x x TCF23X22L x x TCF23X24L x x TCF24X16S x x 9418 TCF24X18S x x TCF24X20S x x TCF24X22S x x TCF24X24S x x TCF24X22L x x TCF24X24L x x TurboChill technical specifications (R1234ze) Model no. Nominal cooling EER ESEER Free-Cooling Free-Cooling EER Sound 10m (dba) Dimensions (H x W x L)(mm) Regular Quiet - Single Circuit - Air Cooled TCC11R04G x x 2626 TCC11R06G x x 3758 TCC11R08G x x 4890 TCC12R08G x x 4890 TCC12R10G x x 6022 TCC12R12G x x 7154 TCC12R14G x x 8286 Regular Quiet - Dual Circuit - Air Cooled TCC22R08G x x 4890 TCC22R10G x x 6022 TCC22R12G x x 7154 TCC22R14G x x 8286 TCC23R12G x x 7154 TCC23R14G x x 8286 TCC23R16G x x 9418 TCC23R18G x x TCC24R16G x x 9418 TCC24R18G x x TCC24R20G x x TCC24R22G x x TCC24R24G x x Extra Quiet - Single Circuit - Air Cooled TCC11X04G x x 2626 TCC11X06G x x 3758 TCC11X08G x x 4890 TCC12X08G x x 4890 TCC12X10G x x 6022 TCC12X12G x x 7154 TCC12X14G x x 8286
13 TurboChill technical specifications (R1234ze) Continued 12 Model no. Nominal cooling EER ESEER Free-Cooling Free-Cooling EER Sound 10m (dba) Dimensions (H x W x L)(mm) Extra Quiet - Dual Circuit - Air Cooled TCC22X08G x x 4890 TCC22X10G x x 6022 TCC22X12G x x 7154 TCC22X14G x x 8286 TCC23X12G x x 7154 TCC23X14G x x 8286 TCC23X16G x x 9418 TCC23X18G x x TCC24X16G x x 9418 TCC24X18G x x TCC24X20G x x TCC24X22G x x TCC24X24G x x Regular Quiet - Single Circuit - FreeCool TCF11R06G x x 3758 TCF11R08G x x 4890 TCF12R08G x x 4890 TCF12R10G x x 6022 TCF12R12G x x 7154 TCF12R14G x x 8286 Regular Quiet - Dual Circuit - FreeCool TCF22R10G x x 6022 TCF22R12G x x 7154 TCF22R14G x x 8286 TCF23R12G x x 7154 TCF23R14G x x 8286 TCF23R16G x x 9418 TCF23R18G x x TCF24R16G x x 9418 TCF24R18G x x TCF24R20G x x TCF24R22G x x TCF24R24G x x Extra Quiet - Single Circuit - FreeCool TCF11X06G x x 3758 TCF11X08G x x 4890 TCF12X08G x x 4890 TCF12X10G x x 6022 TCF12X12G x x 7154 TCF12X14G x x 8286 Extra Quiet - Dual Circuit - FreeCool TCF22X10G x x 6022 TCF22X12G x x 7154 TCF22X14G x x 8286 TCF23X12G x x 7154 TCF23X14G x x 8286 TCF23X16G x x 9418 TCF23X18G x x TCF24X16G x x 9418 TCF24X18G x x TCF24X20G x x TCF24X22G x x TCF24X24G x x ) Nominal cooling capacity and EER for air cooled units is at 7/13 C water and 35 C ambient temperature* 2) Nominal cooling capacity and EER for Free Cooling units is at 10/16 C water and 35 C ambient temperature* 3) ESEER based on Eurovent standard calculation method 4) Nominal free-cooling capacity at 16 C Return, 20% ethylene glycol, fl ow rate based on the nominal duty and a 2 C ambient temperature 5) Free-cooling EER at 16 C return water; 20% ethylene glycol; 2 C ambient temperature and based on TOTAL input power of fans * Based on TOTAL input power of compressors and fans For application specifi c data please contact Airedale Performance data calculated in accordance with BSEN and Eurovent 6/6 Nomenclature explained TCF 1 2 R 14 L - 12 TCC & TCF 1 / R / X 4-24 S / L / G TurboChill and TurboChill FC (TCC and TCF respectively) Number of Circuits (1 or 2) Number of Compressors (1 to 4) Noise Variant (Regular Quiet R or Extra Quiet X) Number of Fans (4 to 24) Compressor Code (S=TT300, L=TT350 or G=TG310) 1-28 Evaporator Code
14 13 Performance tested and proven effi ciencies Quality is assured by our on-site, world-class testing and production facilities and the application of the latest manufacturing techniques and continuous improvement. High efficiency cooling at John Lewis TurboChill FreeCool with low GWP refrigerant R1234ze is currently cooling shoppers visiting the new 15 million John Lewis store in York. John Lewis was built on the principles of being a responsible business and as part of its wider corporate social responsibility strategy, is committed to reducing its carbon footprint. The TurboChill system was selected, as it provided the best solution for John Lewis, creating perfect synergy to a range of stringent sustainable design requirements. National Gallery, London IBM data centre, London Airedale ticked all the boxes in terms of footprint, build quality, new technology such I believe we are the fi rst company in the world to install a TurboChill FreeCool chiller. as the centrifugal compressor, and high When the data centre is operating in free effi ciency. The National Gallery is a high cooling mode, the PUE has been measured user of energy because of its large areas at 1.36 and we expect that to reduce further of air conditioned space. The Gallery s goal as we install more equipment. is to reduce energy consumption and the TurboChill assists that. Martin Goswell Project Engineer, Troupe, Bywaters and Anders Bob Finn Programme Manager, EDF Energy
15 14 Total support Whenever you need it At Airedale, we don t just manufacture and supply cooling and refrigeration products; we also provide a broad range of supporting services to ensure our customers receive the best possible aftersales care. With more than 40 years experience in business critical cooling, investing in an Airedale cooling or refrigeration solution means that you can benefi t from our advice, expertise and technical support too. From design and selection, through to commissioning and beyond, we make sure your system reduces your total cost of ownership, whilst providing maximum availability and longevity. Service plans Maximising your system s effectiveness 24/7 An Airedale service plan provides a planned, preventative maintenance package to sustain the optimum effi ciency of your system, enabling the user to see real savings in energy costs and reduced carbon emissions. With Airedale, you can rest assured that help is never far away. Our 24/7 emergency helpline and call out service is available 365 days of the year, ensuring that we are always on hand to provide expert advice and immediate help, day or night. A guaranteed emergency response time means that a qualifi ed Airedale engineer will be with you in no time, therefore maximising your system s uptime. Service plans also ensure F Gas compliance and incorporate a full parts and labour warranty for the fi rst 12 months. For more information visit * For customers outside the UK, our international distributors trained by Airedale would be pleased to offer service on Airedale units Talk directly with an experienced engineer Have complete control of your site 24/7 support; maintenance and spares Develop your skills Find out how we design our systems to reduce your whole life costs. Our highly experienced engineers are adept at tailoring our systems to suit your requirements. +44 (0) Customers with critical sites can benefi t from our remote monitoring facility. Aftersales services include chiller sequencing, network setup and integration as well as a live demonstration and training centre at our head offi ce. Immediate help on hand to keep your critical cooling system operational. Realise the full potential of your system; improve its longevity and effi ciency and be F Gas compliant. Avoid downtime with our fast, effi cient spares service. Learn more about your cooling system by attending an air conditioning and refrigeration course in our purpose-built training school. Train on high-tech cooling systems and fully operational rigs in our dedicated workshops. Industry recognised courses also available. [email protected] for further details.
16 WINNER Energy Saving Product of the Year. Distributed by: ISO EMS52086 ISO 9001 FM00542 Airedale International Air Conditioning Limited Leeds Road, Rawdon, Leeds LS19 6JY, England Tel: +44 (0) Fax: +44 (0) All specifi cations are subject to change without prior notice ENG-CHIL-TCC/TCF-06-14
EasiCool. 6-64kW DX AIR. www.airedale.com. Precision Air Conditioning
Precision Air Conditioning DX / CW EasiCool 6-64kW ENHANCED EASICOOL RANGE: + Up to 37% increase in EER + Up to 8% more cooling kw/m 2 Compared with our previous generation EasiCool units HFC R410A HFC
Data Centre. Flexible, high efficiency cooling solutions. www.airedale.com CONDITIONING CONDENSING UNITS CONTROLS SERVICE TRAINING
Sector Data Centre Data Centre Flexible, high efficiency cooling solutions IT COOLING PRISION AIR CONDITIONING CHILLERS CONDENSERS & CONDENSING UNITS www.airedale.com BRITISH MANUFACTURER ENERGY EFFICIENCY
Data Centre. Flexible, high efficiency cooling solutions. www.airedale.com CONDITIONING CONDENSING UNITS CONTROLS SERVICE TRAINING
Sector Data Centre Data Centre Flexible, high efficiency cooling solutions IT COOLING PRISION AIR CONDITIONING CHILLERS CONDENSERS & CONDENSING UNITS www.airedale.com BRITISH MANUFACTURER ENERGY EFFICIENCY
60-150kW. For more information on Airedale visit www.barbourproductsearch.info SmartCool. 0-150kW. > SmartCool. www.airedale.com
60-150kW 0-150kW > Next generation precision air conditioning Typical applications > Data centres and computer rooms > Telecommunications and ISP facilities > Clean rooms > Switching stations > Laboratories
Product Guide. www.airedale.com BRITISH MANUFACTURER TRAINING ENERGY EFFICIENCY
Product Guide BRITISH MANUFACTURER ENERGY EFFICIENCY CONTROLS SERVICE TRAINING www.airedale.com 01 Quick reference Find the right solution for your application Six product ranges supported by an extensive
Air-cooled Chillers with High Speed Centrifugal Compressors
Air-cooled Chillers with High Speed Centrifugal Compressors Model GVAF-X 575-1613 kw Model GVAF-XP 720-1220 kw Model GVAF-XPG 500-1257 kw 1 Trane Sintesis excellent Air-cooled Chillers with High Speed
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
State of the Art Energy Efficient Data Centre Air Conditioning
- White Paper - State of the Art Energy Efficient Data Centre Air Conditioning - Dynamic Free Cooling - Release 2, April 2008 Contents ABSTRACT... 3 1. WHY DO I NEED AN ENERGY EFFICIENT COOLING SYSTEM...
5-21kW. Ecotel Indoor Range. - 21kW. > Ecotel Indoor Range. www.airedale.com. Typical Applications
5-21kW - 21kW > Ecotel Indoor Range Typical Applications > Telecommunications > Internet service providers > Computer rooms > Switching / Relay stations www.airedale.com Specifications Ecotel Indoor The
Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed
Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires
Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA
Paul Oliver Sales Director Paul Oliver, Airedale Tom Absalom, JCA Airedale an overview 25,000m 2 UK premier test centre 450 staff Global distribution A Modine company Modine centre of excellence Airedale
5-60kW. EasiCool Range. - 60kW. www.airedale.com. Typical Applications
5-60kW - 60kW > Typical Applications > Telecommunications & ISP facilities > Computer rooms > Clean rooms > Switching stations > Laboratories www.airedale.com Specifications The newly developed EasiCool
Direct Fresh Air Free Cooling of Data Centres
White Paper Introduction There have been many different cooling systems deployed in Data Centres in the past to maintain an acceptable environment for the equipment and for Data Centre operatives. The
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75
Specifications COOLING ONLY / HEAT PUMP 005 006 007 Capacity (Eurovent) Cooling kw 5.2 6.0 7.1 Heating kw 5.65 6.35 7.75 Nominal input (Eurovent) Cooling kw 1.89 2.35 2.95 Heating kw 1.97 2.24 2.83 EER
ThermoStar Refrigeration Air Dryers
ThermoStar Refrigeration Air Dryers Why dry compressed air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. These problems
Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany
Life Cycle Costing Analysis of Water-cooled Chillers Chillventa Nuremburg, Germany Spring 2012 Description Life Cycle Cost Analysis is a method of determining and comparing the total costs of investment
your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction
your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction What is DNSS EcoSave? The Daikin Network Service System (DNSS EcoSave) is a Daikin developed internet based remote
Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE
Hitachi Air Conditioning Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE Contents Page 04 Product Range 08-09 RAC Summit Wall Mounted 10 RAC Shirokuma Wall mounted 11 RAC S Series - Wall
Making a world of difference. Turbocor centrifugal compressors for air-conditioning systems
Making a world of difference Turbocor centrifugal compressors for air-conditioning systems Leading a new era in performance Today, the world is looking for HVAC technology that makes a difference in efficiency,
AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -
AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness
News in Data Center Cooling
News in Data Center Cooling Wednesday, 8th May 2013, 16:00h Benjamin Petschke, Director Export - Products Stulz GmbH News in Data Center Cooling Almost any News in Data Center Cooling is about increase
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
New Deluxe Wall Mounted Heat Pump Series EXTERIOS
New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History
System solution for data centres
1 System solution for data centres Energy-efficient air conditioning with ServeLine Cooling IT infrastructure, high availability, low energy costs and communication with DCIM systems all in one from your
For every mission, there is a Vector. VECTOR
For every mission, there is a Vector. VECTOR Long haul Long haul & distribution Distribution For every mission, There is a vector. Delivering fresh and frozen goods from farm to fork is a complex process.
FULL DC INVERTER SYSTEMS
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation
PFT Two stage axial fan The high pressure fan for modern boiler plants
PFT Two stage axial fan The high pressure fan for modern boiler plants Modern boilers equipped with complete flue-gas cleaning systems demand fans for high pressure that can be controlled quickly and accurately
Drives and motors. A guide to using variable-speed drives and motors in data centres
Drives motors A guide to using variable-speed drives motors in data centres The power behind the data Private public businesses, from banks to supermarkets, to telecommunications companies internet providers
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III.1. Large Roof Mount PN: 89-3037 Roof Mount Unit Eco 136 Parallel roof mount Air-conditioning and ventilation systems The Eco 136
RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features
RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,
Your own power station: For continuous power
Mass Combi Ultra Your own power station: For continuous power Compact and lightweight inverter/battery charger Seamless switching between generator and grid Separate second charger Integrated MPPT solar
Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)
Drives and motors A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC) The power behind the data Private and public businesses, from banks to
Daikin Altherma. hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Why choose Daikin? As an industry leader, Daikin combines broad experience, technical innovation and responsive customer service to help you meet
Excool Indirect Adiabatic and Evaporative Data Centre Cooling. World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling
Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling Indirect Adiabatic and Evaporative Data Centre Cooling Solutions by
Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.
Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.5-15 bar SX Series SX Compact and powerful Today s users expect maximum availability
White Paper Rack climate control in data centres
White Paper Rack climate control in data centres Contents Contents...2 List of illustrations... 3 Executive summary...4 Introduction...5 Objectives and requirements...6 Room climate control with the CRAC
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
Hybrid heat pumps. saving energy and reducing carbon emissions
Hybrid heat pumps saving energy and reducing carbon emissions Bart Aspeslagh Product planning and new technology manager, Daikin Europe NV. [email protected] Stefanie Debaets Design engineer,
Elements of Energy Efficiency in Data Centre Cooling Architecture
Elements of Energy Efficiency in Data Centre Cooling Architecture Energy Efficient Data Center Cooling 1 STULZ Group of Companies Turnover 2006 Plastics Technology 400 Mio A/C Technology 200 Mio Total
The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity
Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings
Oil-Free Screw Compressors. Water-injected Technology. Rely on GD to provide the perfect fit
Oil-Free Screw Compressors Water-injected Technology Rely on GD to provide the perfect fit Why oil-free? Don t compromise on quality If 100% clean and oil-free compressed air is a requirement for your
Are these noise cancelling devices needed to make your chiller quiet??
Are these noise cancelling devices needed to make your chiller quiet?? Not on this chiller! Some sound barriers should never be broken. Government authorities recommend that exposure to loud noise over
Screw Compressors 11-22kW
INDUSTRIALS GROUP Screw Compressors 11-22kW KSA Plus Fixed Speed, KSV Variable Speed Smart and affordable CHAMPION COMPRESSED AIR TECHNOLOGIES KSA Plus Screw Compressors Up to 45 C ambient temperature
7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America
7 Best Practices for Increasing Efficiency, Availability and Capacity XXXX XXXXXXXX Liebert North America Emerson Network Power: The global leader in enabling Business-Critical Continuity Automatic Transfer
york air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
RiMatrix S Make easy.
RiMatrix S Make easy. 2 RiMatrix S Rittal The System. The whole is more than the sum of its parts. The same is true of Rittal The System. With this in mind, we have bundled our innovative enclosure, power
Top Technology for Industry, Agriculture, Business and Communities
Top Technology for Industry, Agriculture, Business and Communities CHP The Technology with a Potential for Saving Energy Combined Heat and Power (CHP) is a highly efficient technology for the conversion
Apartment and Communal Heating Solutions
Apartment and Communal Heating Solutions Apartment and Communal Heating Due to the increasing requirements for more energy efficient buildings and changes to the Code for Sustainable Homes Legislation,
- White Paper - Data Centre Cooling. Best Practice
- White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH
Solutions for Building Air Comfort and Fire Safety
Solutions for Building Air Comfort and Fire Safety Environment Economical Expertise Providing the best possible air comfort and safety for people by: Protecting our shared environment Developing energy
Scroll compressors for Low GWP Heat Pumps using R290 natural refrigerant. Pierre Ginies, Next Heat Pump Generation 2015 p.ginies@danfoss.
Scroll compressors for Low GWP Heat Pumps using R290 natural refrigerant Pierre Ginies, Next Heat Pump Generation 2015 [email protected] Danfoss Commercial Compressors Leading compressor R&D and manufacturing
Chiller/Heat pumps 30AWH. Reversible. Monobloc inverter
Chiller/Heat pumps 30AWH Reversible Monobloc inverter C O M P A C T, R E L I A B L E A N D E F F I C I E N T Reversible Compact, reliable and efficient 2 The new AquaSnap PLUS chillers and reversible heat
D SERIES MODULAR AIR-COOLED SCROLL CHILLER. TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:65~130kW SUPER HIGH AMBIENT OPERATION TO 43
D SERIES MODULAR AIR-COOLED SCROLL CHILLER TECHNICAL SALES GUIDE-50Hz CAPACITY RANGE:65~130kW SUPER HIGH AMBIENT OPERATION TO 43 CONTENTS 1.MODELS LIST... 3 2.NOMENCLATURE... 3 3.FEATURES... 3 4.PRODUCT
Blade Server & Data Room Cooling Specialists
SURVEY I DESIGN I MANUFACTURE I INSTALL I COMMISSION I SERVICE SERVERCOOL An Eaton-Williams Group Brand Blade Server & Data Room Cooling Specialists Manufactured in the UK SERVERCOOL Cooling IT Cooling
ROTEX gas hybrid heat pump. A strong team.
ROTEX gas hybrid heat pump A strong team. The new ROTEX HPU hybrid gas hybrid heat pump always selects the most favourable heating mode automatically. For a long time the general opinion was that a heat
Daikin Altherma Hybrid Heat Pump
Daikin Altherma Hybrid Heat Pump Smart technology for the best of both worlds NATIONAL HEAT PUMP 19 JUNE 2014 ICC BIRMINGHAM WINNER Forward thinking Now is the time to rethink the way we heat our homes
DUCTED AIR CONDITIONING SOLUTIONS
DUCTED AIR CONDITIONING SOLUTIONS H I G H E N E R G Y E F F I C I E N C Y B A C K E D B Y A 5 Y E A R F U L L P A R T S & L A B O U R W A R R A N T Y DUCTED RANGE WHY CHOOSE FUJITSU? AUSTRALIA S FAVOURITE
Natural geothermal energy.
ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.
Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools
Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL
Training courses 2016
Training courses 2016 The UK s leading specialist air conditioning and refrigeration training provider Get ahead, develop your skills and knowledge Professional training and practical instruction on latest
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
Inverter technology. bulletin
Inverter technology application bulletin What is the inverter component? The inverter is an electronic power component that continuously varies the electricity supply frequency of an electric motor. The
Daikin Altherma hybrid heat pump. The natural combination
Daikin Altherma hybrid heat pump The natural combination Daikin Altherma hybrid heat pump, the natural combination Why choose Daikin Altherma hybrid heat pump? What the customer wants: more energy efficient
Visions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
marine/bespoke split applications
split applications marine/bespoke evaporators, condensers and split air conditioning systems suitable for a multitude of applications such as coastal, extreme high and low ambients, harsh dusty environments
Daikin Altherma Hybrid Heat Pump
your comfort. our world. Daikin Altherma Hybrid Heat Pump Smart heating technology for the best of both worlds Heating Integrated Solutions Ventilation Air Conditioning Refrigeration Forward thinking About
COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C
COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing
How To Make A Fronius Cl Power Inverter
Fronius CL PV central inverter with Fronius MIX concept Modular system. Maximum yield. The Fronius CL combines high-yield power electronics with the unique, modular system design of up to 15 identical
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
HEATING, VENTILATION & AIR CONDITIONING
HEATING, VENTILATION & AIR CONDITIONING as part of the Energy Efficiency Information Grants Program Heating and cooling can account for approximately 23 % of energy use in pubs and hotels 1. Reducing heating
Inverter Air Conditioning for Light Commercial Use
Inverter Air Conditioning for Light Commercial Use 02 Cost Saving Comfort An efficient use of time 03 SDISuper Digital Inverter Very efficient energy consumption Keeps down operating costs Heater operation
Gree Solar Hybrid Hi Wall Inverter Air Conditioner
Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar
Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort
Heat Pump Product Brochure 2015/2016 Premier Series Hi-Wall Split Systems Everyday Comfort Everyday Innovation We design with you in mind. You ll find that Haier Heat Pump units are quiet, efficient and
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
CoolTeg Plus Chilled Water (CW) version: AC-TCW
version: 12-04-2013 CONTEG DATASHEET TARGETED COOLING CoolTeg Plus Chilled Water (CW) version: AC-TCW CONTEG, spol. s r.o. Czech Republic Headquarters: Na Vítězné pláni 1719/4 140 00 Prague 4 Tel.: +420
Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology
your comfort. our world.» Up to 70% energy saving with BLDC motor technology» Instant adjustment to temperature and relative humidity changes» Low noise levels» Highly flexible solutions Fan Coil Units
Refrigerant Choices for Commercial Refrigeration. Finding the Right Balance
Refrigerant Choices for Commercial Refrigeration Finding the Right Balance 2 CONTENTS 1. Executive Summary 1.1. Introduction 4 1.2. Glossary of terms 5 5. Cases configuration 5.1. Introduction 17 5.2.
Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues
Design Guide Retrofitting Options For HVAC Systems In Live Performance Venues Heating, ventilation and air conditioning (HVAC) systems are major energy consumers in live performance venues. For this reason,
VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water
2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation
SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
Commercial Hot Water. Make a difference...
Commercial Hot Water Make a difference... heat S O L A R pumps The Company Quantum Energy Technologies The Quantum story is based on innovation and the quest to harness renewable energy to produce sustainable
IEC DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM
DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM THE GLOBAL DATA CENTRE MARKET The data centre air conditioning market is expected to grow with a CAGR (compound annual growth rate) of about 12% in the next
Commissioning - Construction Documents (Page 1 of 6)
Commissioning - Construction Documents (Page 1 of 6) A. General Information Climate Zone: Building Type: Conditioned Area (sf): Reviewer's Name: Reviewer's Agency: Note: Design Review for each system/subsystem
IV. Rear Mount System
Mobile Climate Control 45 MCC Reference Manual 2014 PN: 89-3069 Rearmount Air Conditioning System Eco RM Capacity, Reliability, and Serviceability MCC Eco RM unit, selected as preferred equipment by leading
Heating, ventilation and air conditioning equipment. A guide to equipment eligible for Enhanced Capital Allowances
Heating, ventilation and air conditioning equipment A guide to equipment eligible for Enhanced Capital Allowances 2 Contents Introduction 03 Background 03 Setting the scene 03 Benefits of purchasing ETL
Liebert EFC from 100 to 350 kw. The Highly Efficient Indirect Evaporative Freecooling Unit
Liebert EFC from 100 to 350 kw The Highly Efficient Indirect Evaporative Freecooling Unit Liebert EFC, the Highly Efficient Indirect Evaporative Freecooling Solution Emerson Network Power delivers innovative
AIR SOURCE CHILLERS FOR OUTDOOR INSTALLATION
AIR SOURCE CHILLERS FOR OUTDOOR INSTALLATION HIGH EFFICIENCY LATEST CONTROL SYSTEM LEED RELEVANT PRODUCT EXTREMELY SILENT OPERATIONS Features High efficiency chiller, air source for outdoor installation
FTQ. Daikin Inverter Ducted Heat Pump
FTQ Daikin Inverter Ducted Heat Pump A TRADITIONAL CENTRAL AIR SYSTEM MADE BETTER WITH DAIKIN CONSTANT COMFORT INVERTER TECHNOLOGY. The Daikin Inverter Ducted Heat Pump line is a cost effective alternative
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures
Data Realty Colocation Data Center Ignition Park, South Bend, IN Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures Project Overview Data Realty is a data center service provider for middle
Cool Design for Homes and Offices
AIR BLUE AIR BLUE air conditioning Homes Easy to install and use, quiet, attractive, and designed to fit any space: there are Cool Design for Homes and Offices a lot of reasons why Air Blue air conditioners
Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity
Liebert Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment Precision Cooling For Business-Critical Continuity The Intelligent Data Center Cooling Solution: Liebert Trust the industry
AERIS DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM
DATA CENTRE INDIRECT EVAPORATIVE COOLING SYSTEM THE GLOBAL DATA CENTRE MARKET The data centre air conditioning market is expected to grow with a CAGR (compound annual growth rate) of about 12% in the next
Why and How we Use Capacity Control
Why and How we Use Capacity Control On refrigeration and air conditioning applications where the load may vary over a wide range, due to lighting, occupancy, product loading, ambient weather variations,
Daikin Altherma Hybrid Heat Pump
your comfort. our world. Daikin Altherma Hybrid Heat Pump The natural combination Heating Integrated Solutions Ventilation Air Conditioning Refrigeration About Daikin Forward thinking... Daikin has a worldwide
Water cooled chiller plant (cp/vs)
Data Center Water cooled chiller plant (cp/vs) Design Envelope File No: 9.573 Date: december 16, 2014 Supersedes: 9.573 Date: november 14, 2014 design envelope s performance improvements are among the
IPSIP M series-m Modular Data Center
IPSIP M series-m Modular Data Center IPSIP MODULAR TECHNOLOGIES. 1 With the rapid development of cloud computing and mobile Internet businesses, the growth of IT density and energy consumption are bringing
EHDC. Cooling system for Data Center and server cabinets.
EHDC Cooling system for Data Center and server cabinets. EHDC PEN LP EHDC L is a High Density Cooling module for an pen Loop configuration. It is ideally installed with Enoc Systems cold corridor containment
Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS
Solar MAX ELECTRIC BOOSTED SPECIFICATIONS Proudly Australian ALL AUSSIE GAS & ELECTRIC BOOSTED WATER S Harness the power of the Sun. 1 Energy efficiency that s out of this world AquaMAX high efficiency