FOM Line Driver ST FOM Line Driver SM



Similar documents
Remote Port USB Port User Guide

Voice Magic Plus MARCH 2001 CP179A CUSTOMER SUPPORT INFORMATION

Fiber Optic Converter I Fiber Optic Converter II

Monitor Access Unit JUNE 1999 TS760A TS761A TS765A TS766A CUSTOMER SUPPORT INFORMATION

Use this HDMI and HDCP-compliant USB converter for streaming media files stored on BLACK your PC to BOX an HD screen with HDMI input.

BLACK BOX Works with the Black Box ServReach KVM Gate (KVIP1000A), ServReach KVM Cube (KVIP1001A), or as a standalone device.

Copyright Black Box Corporation. All rights reserved.

High specification KVM switches that interface precisely with the Black Box ServView Rack Tray series.

Quick Start Guide. Rackmount Remote Power Manager. Use this guide to quickly set up your power manager. Customer Support Information

Black Box Tech Support: FREE! Live. 24/7.

BLACK BOX. Switch between two or four different HDMI sources to a single display. 2 x 1 or 4 x 1 HDMI Switch 4K VSW-HDMI2X1-4K VSW-HDMI4X1-4K

User Manual. ipad, Chromebook, Tablet, and Laptop Lockers. Mobile, secure, and powered storage for up to 40 computing devices.

Turns a VGA monitor into a video monitor with remote switching capability. BLACK BOX

intrusion prevention, vulnerability management, and regulatory compliance.

Review of Multi-Purpose Amplifier HS101A

JANUARY 2001 TS825A TS826. Microscanner Pro

2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization

Music On-Hold Plus MARCH 2005 TE150A-R2 TE151 CUSTOMER SUPPORT INFORMATION

Black Box Tech Support: FREE! Live. 24/7.

Turns a VGA monitor into a video monitor with remote switching capability. BLACK BOX

Send VGA output to one local monitor and to as many as nine remote monitors BLACK up to 250 BOX feet (76.2 m) away.

VDSL Line Driver DECEMBER 2006 ME0010A-VDSL-R2

Remote Console Port + Remote Power Manager. Quick Start Guide

This Web smart switch provides /100-/1000-Mbps ports. BLACK BOX

10BASE-T Extender. 10BASE-T Extender FEBRUARY 1999 LZ6000A-R4. Jabber Link Test Activity. Power. Collision. Power 10BASE-T.

Digi-Mux HS FEBRUARY 1996 MX700A CUSTOMER SUPPORT INFORMATION

PC 422/485 Serial Interface

8-Port Serial Host Adapter PCI

Connect, control, and manage up to 16 serial RS-232/485 devices BLACK BOX via a single USB port on your PC.

Copyright Black Box Corporation. All rights reserved.

Network Power Switch Jr.

Veri-NAC the fastest to deploy, easiest to use

Extend USB connections beyond the desktop, as far as 131 feet (40 m) over CAT5 USB devices.

USB Director RS422/RS485 Hub 2-Port USB Director RS422 Hub 4-Port NT 4.0 Software Support Upgrade

RS-232/485 Converter

USB Single-Port Hub (RS-422/485)

Extend Ethernet with full-duplex transmission up to Mbps more than BLACK four miles over BOX a pair of copper wires.

Transform your wired projector into a high-end wireless projector.

2-Port RS-232 PCI Bus Serial Host Adapter

VDSL Line Driver DECEMBER 2004 ME0010A-VDSL ME0011A-VDSL

Expand existing, leased line, polled networks without adding computer ports BLACK or communications links.

High-Speed Parallel PCI PC Plus Adapter

Phone Coupler II NOVEMBER 1996 MC155A-R2 CUSTOMER SUPPORT INFORMATION

User Manual. 30-Device ipad, Chromebook, Tablet, and Laptop Cart. Mobile, secure, and powered storage for up to 30 computing devices.

Extend Ethernet with full-duplex transmission up to 10.8 Mbps over two pairs BLACK of copper. BOX

Multi-Rate Ethernet Extender

Express Ethernet Switches

T7 Plus Network Tower NT

Short-Haul Modem-FSK RS-485 Modules

Gigabit Compact Media Converter

DeeSel.1 Industrial Ethernet Extender Multi-Drop Unit, G-SHDSL 2-Wire, 5.7 Mbps

CAT5 Multi Video System (Video/Audio/RS232)

Copyright Black Box Corporation. All rights reserved.

Convert 10/100/1000BASE-T UTP to 1000BASE-X or 100BASE-FX fiber and provide Power-over-Ethernet (PoE+).

Dual Channel HS Sync/Async V.35 Serial Interface

Provides first-class HD video transmission

Express Ethernet Switch LB9019A-R2

Video to VGA Converter/Switch

Share one HDMI display output (monitor, projector, or TV) between multiple BLACK HDMI BOX inputs.

T1/E1 Fiberoptic Line Driver (T1/E1 FOLD)

Convert any HD video source, Component or RGB (VGA) into an HDTV channel. BLACK BOX

Copyright Black Box Corporation. All rights reserved.

Measure and find faults in data, power, and communications video cable. BL A CK B OX

Line Share 120H FEBRUARY 1997 FX120A. Phone Line Manager 120H CUSTOMER SUPPORT INFORMATION

Gigabit 1000BASE-SX/LX PCI 64-/32-Bit Fiber NICs

DSLAM Chassis: 1-x-4-Slot or 2-x-12-Slot DSL Access Multiplexor Uplink Module

Dual Link DVI Repeater with EDID Mgmt

RS-232/422/485 2-Port PCI Card, Opto-Isolated

Improves the performance of TCP-based traffic on the Internet, so your Web sites BLACK load BOX and video streams faster.

Pure Networking Broadband Router Users Guide

Managed Port Multiplier 3- and 4-Port

Secure Site Manager 8 Secure Site Manager 16 User s Guide

Extend 10/100Base-TX Ethernet up to 10,000 feet (3 km)

Network Management Software


Featuring enhanced biometric security with two-factor authentication,black the perfect blend of security and simplicity.

2-Wire Short-Range DSL Line Driver (mdsl with V.35) (mdsl with X.21)

Share a single xdsl/cable modem high-speed wireless Internet connection between BLACK BOX up to 253 users.

BERT Tester MAY 2005 TS940A-R2 CUSTOMER SUPPORT INFORMATION

Provides eight 10/100/1000BASE-T(X) ports plus two Gigabit SFP open slots.

TV to VGA Converter/Line Doubler

Internet Access Router

LR120A, LR121A, LR122A, LR125A WAN Access Routers. Getting Started Guide

A high performance KVM extender that can transmit up to two high resolution DisplayPort video streams plus high speed USB and digital/ analog audio.

2-Port RS-232/422/485 PCI Host Adapter

Welcome to the ServSwitch Family!

1101 and 1102 Secure Device Servers

Remote Console Manager User s Manual

Terminal Server User Guide

Extend video, audio, and USB signals via an existing LAN.

BLACK BOX. Installation Guide. Hybrid PBX and VoIP Gateway with (4) or (12) FXOs

SINGLE MODE FIBER OPTIC A/B SWITCH (LATCHING)

Connect VoIP phones, IP cameras, or any PoE PD devices through manageable, switched links.

FIBER OPTIC A/B/C SWITCH (Latching)

Cyclades-TS User Guide. Version TS 1.4.0

4-, 8-, and 16-Port ServSwitch EC Series IP KVM Switch

Supports http and SNMP interface for switch management.

FOM-5A, 6A. Asynchronous Fiber Optic Modem

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

User Manual IC-485AI

Transcription:

FERURY 1998 ME540-ST ME540-SM FOM Line Driver ST FOM Line Driver SM CUSTOMER SUPPORT INFORMTION Order toll-free in the U.S.: Call 877-877-OX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 Mailing address: lack ox Corporation, 1000 Park Drive, Lawrence, P 15055-1018 Web site: www.blackbox.com E-mail: info@blackbox.com

FEDERL COMMUNICTIONS COMMISSION ND CNDIN DEPRTMENT OF COMMUNICTIONS RDIO FREQUENCY INTERFERENCE STTEMENTS This equipment generates, uses, and can radiate radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference. Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. This digital apparatus does not exceed the Class limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications. Le présent appareil numérique n émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe prescrites dans le Règlement sur le brouillage radioélectrique publié par le ministère des Communications du Canada. INSTRUCCIONES DE SEGURIDD (Normas Oficiales Mexicanas Electrical Safety Statement) 1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado. 2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura. 3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas. 4. Todas las instrucciones de operación y uso deben ser seguidas. 5. El aparato eléctrico no deberá ser usado cerca del agua por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc. 6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante. 7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante. 8. Servicio El usuario no debe intentar dar servicio al equipo eléctrico más allá a lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado. 9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación. 10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor. 11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato. 12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. 13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato. 14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante. 15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia. 16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo. 17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación. 18. Servicio por personal calificado deberá ser provisto cuando: : El cable de poder o el contacto ha sido dañado; u : Objectos han caído o líquido ha sido derramado dentro del aparato; o C: El aparato ha sido expuesto a la lluvia; o D: El aparato parece no operar normalmente o muestra un cambio en su desempeño; o E: El aparato ha sido tirado o su cubierta ha sido dañada.

Contents FOM LINE DRIVER ST ND SM Chapter 1. Specifications...4 2. Introduction...5 2.1 Ports...5 2.2 Speed and Distance...5 3. Configurations...6 3.1 Network Mode...6 3.2 Master/Slave Mode...7 3.3 Point-to-Point...8 4. Installation...9 4.1 Setup...9 4.2 RS-232...10 4.3 RS-485...10 4.4 20-m Current Loop (Point to Point)...13 5. Quick Setup Guide...14 6. Troubleshooting...17 6.1 pplication Problems...17 6.2 Calling Your Supplier...17 6.3 Shipping and Packaging...17 Page TRDEMRKS USED IN THIS MNUL ST is a registered trademark of merican Telephone and Telegraph Company. ll applied-for and registered trademarks are the property of their respective owners. 3

FOM LINE DRIVER ST ND SM Protocol Speed Maximum Distance Operation No. of Drops Supported 64 Interface Connectors Indicators User Controls Link udget Fiber Launch Power Receiver Sensitivity Wavelength Cable Requirements MTF Relative Humidity Tolerance Operating Temperature Storage Temperature Power Size Weight 1. Specifications synchronous Transparent through 20 Kbps on 20-m current loop port, 64 Kbps on RS-232 port, 128 Kbps on RS-485 port 5000 feet (1524 m) on 62.5 micron Network or master/slave mode, multipoint half-duplex (NOTE: software protocol is required); Point-to-point line driver operation, full duplex RS-232 DCE/DTE, RS-485, 20-m current loop active or passive transmit and receive, fiberoptic transmit and receive (1) D9, (4) ST or SM, (1) 4-screw terminal block (10) LEDs: 232, 485, 20m, NETWORK, MSTER, SLVE, PORT TXD, PORT D, PORT TXD, PORT D (1) Pushbutton: Pressed in enables DL (Digital Loopback) mode, and fully extended enables NORML mode 50-125µ cable: 2.5 d; 62.5-125µ cable: 6 d; 100-140µ cable: 11.5 d -14 d -25 d 820 nm Use multi-mode fiber cable; use up to 200 micron fiberoptic cable; 62.5 micron fiber is recommended 168,000 hours 10 to 95%, noncondensing 32 to 114 F (0 to 45 C) -40 to 176 F (-40 to 80 C) 115 VC, 60/50 Hz, external (part number PS154) 1.8"H x 5.5"W x 8.5"D (4.6 x 14 x 21.6 cm) 2 lb. (0.9 kg) 4

FOM LINE DRIVER ST ND SM With the FOM Line Driver, you can use an RS-232, RS-485, or 20-m digital current-loop device in a multi-drop half-duplex or point-to-point full-duplex environment using fiber optics as the transmission media. The Driver is user-configurable in any of these operating modes: network mode, master/slave mode, or full-duplex point-to-point configuration. 2.1 Ports The FOM Line Driver has a single RS-232 D9 female connector. TX and are parallel with a 20-m current-loop and RS-485 interface sharing a common terminal block with a switch to select the desired interface. This will let you connect an RS-232, RS-485, or current-loop device to a fiberoptic link. There are also two sets of fiberoptic receivers and transmitters with ST or SM connectors supporting standard fiber cable through 200 microns (multimode). 2.2 Speed and Distance 2. Introduction The Line Driver runs at up to 20 Kbps on the 20-m current-loop port, up to 64 Kbps on the RS-232 port, and up to 128 Kbps on the RS-485 port. Maximum distance is 5000 feet (1524 m). Figure 2-1 illustrates the Line Driver s features. CONNECTORS CONNECTORS TX TX D-9 WLLMOUNT POWER SUPPLY TERMINL LOCK Figure 2-1. The FOM Line Driver. 5

FOM LINE DRIVER ST ND SM There are three operating modes you can choose from: network mode, master/slave mode, or point-topoint configuration. In network mode, all of the units are configured. If you want one Line Driver configured as a master and the others as slaves, you need to be in master/slave mode. Finally, point-topoint configuration is a full-duplex mode where both FOM Line Drivers are configured as masters. This chapter describes each scenario in greater detail. Read the entire chapter before deciding which configuration is right for you. 3.1 Network Mode 3. Configurations In this mode, data sent to the transmitter (TX) of the RS-232 D9, 20-m current loop, or RS-485 terminal block is passed out to both optical transmitters (TX). Data received from either optical receiver () is passed through to the opposite optical port s transmitter (TX), to the receiver () of the RS-232 D9, the 20-m current loop, or the RS-485 port. NOTE There is no collision detection. Data Path TX TX TX TX TX TX TX TX 232/485/C. Loop Receiving Receiving 232/485/C. Loop Transmitting Receiving 232/485/C. Loop Receiving Transmitting 232/485/C. Loop Receiving Receiving Fiber Cabling TX TX TX TX TX TX TX TX Figure 3-1. ll units configured in network mode. s you look at the example above, keep these things in mind. In network mode, all of the devices look the same. There are no masters or slaves. Data flow is half-duplex only. ll devices see all data on the network. 6

3.2 Master/Slave Mode FOM LINE DRIVER ST ND SM When the master sends data to the transmitter (TX) of the RS-232 D9, the 20-m current loop, or the RS-485 terminal block, the data is passed through to the master s optical port. From there, it is daisychained to each slave s optical. s each slave receives the data, it is passed through to the D9 and the receive () terminal block. When the data reaches the slave that needs to respond, it will send data to the optical TX port and out to the next daisychained slave in the direction of the master. The information is retransmitted and travels from daisychained slave to slave in the direction of the master until it reaches the master s Port. Figure 3-2 illustrates this configuration. lthough the information is traveling through the other slaves, slaves don t see data from other slaves. This keeps the slaves from having to stop working in order to translate another slave s information. Data Path TX TX TX TX TX TX TX TX Master Transmitting Receiving Slave Receiving Receiving Slave Receiving Transmitting Slave Receiving Receiving Fiber Cabling TX TX TX TX TX TX TX TX Master Slave Slave Slave Figure 3-2. One unit configured as a master, all others as slaves. s you look at the example above, keep these things in mind. Data flow is half-duplex only. The master transmits out of Port only. Slaves transmit out of Port only, and that transmission goes to the master. When a slave receives data in Port, the data is looped back out Port. When a slave receives data in Port, the data is looped back out Port and is sent out the D9 port (from the master). The master receives in Port only. 7

FOM LINE DRIVER ST ND SM 3.3 Point-to-Point Set up as shown in Figure 3-3, the Line Driver can run in full-duplex mode across the fiber connecting an RS-232, RS-485, or 20-m current-loop device to another RS-232, RS-485, or 20-m current-loop device. TX TERMINL LOCK D-9 TX FIER OPTIC CLE TX D-9 TX TERMINL LOCK TX TX Figure 3-3. Point-to-point oth units configured as masters. NOTE The same interface is not required on both sides. 8

4. Installation FOM LINE DRIVER ST ND SM 4.1 Setup Factory-default settings are marked with asterisks. Determine which interface should be active, and set XW2 accordingly. RS-232...XW2* RS-485...XW2 20-m Current Loop...XW2C Determine the mode in which you want the Line Driver to operate. If you want all of the Line Drivers to be configured, choose 0 (on S1, position 1) for Network Mode. If you want the Master/Slave Mode (for either a half-duplex mode where one Line Driver is the master and the others are slaves or for point to point, the full-duplex mode where both Line Drivers are configured as masters), choose 1. S1, Position 1 Mode Select 0 ------Network Mode 1 ------Master/Slave Mode If you choose to operate in Master/Slave Mode, you need to designate whether this Line Driver will be a master or a slave. On S1, set position 2 to 0 if you want the Driver to be a master and 1 if you want it to be a slave. If you chose Network mode above, you do not need to set S1, position 2. S1, Position 2 Master/Slave Select 0 ------Master* 1 ------Slave NOTE To use the following switch positions appropriately, you should have a firm understanding of your network requirements. S1, Position 5 and 6 are used as a pair to bias the Line Driver s receivers and must be moved together. S1, Position 3 and 4 are used as a pair to bias the Line Driver s TX pair and must be moved together. In most RS-485 applications, you would bias your (S1, Position 5 and 6) ON or closed. For example, say you have an RS-485 network in an idle condition with all nodes in the receive mode. Since the drivers are tri-stated, the line voltage could be either positive or negative there s no way to know for sure. If the voltage level at the T1-2 and T1-1 inputs is less than 200mV, the logic level at the output of the will be the last bit received. To force the line into an idle condition, you d need to set the switch S1, Position 5 and 6, which will add resistors. Refer to Figure 4-1. S1, Positions 3 through 6 RS-485 Failsafe/iased Line 0 ------No ias 1 ------iased If you selected RS-485 as your interface, you ll need to set S1, positions 7 and 8, for termination. The physical ends (the first and last Drivers) must be terminated and the ones in between are unterminated. Positions 7 and 8 must be set in pairs (both terminated or both unterminated). Note that a star topology will not work with these Line Drivers. S1, Positions 7 and 8 RS-485 Termination 0 ------Unterminated 1 ------Terminated *Factory default. KEY 0 = Open/Off 1 = Closed/On 9

FOM LINE DRIVER ST ND SM Fiberoptic Cable Connections ecause of the subtleties of the various modes of operation, review Chapter 3, Configurations, for the proper inter-unit connections. If you chose XW2 (RS-232) as your interface selection, go to Section 4.2. If you chose XW2 (RS-485) as your interface selection, go to Section 4.3. If you chose XW2C (20-m current loop) as your interface selection, go to Section 4.4. 4.2 RS-232 Follow these instructions to set up the RS-232 interface. 1. Set XW1. XW1 sets the Driver for DCE. XW1 sets the Driver for DTE. XW1 ------DCE* XW1 ------DTE D9 Pinouts DCE 2 TX Data 3 Data 7 RTS Input 4 DTR Input 8 CTS Output 6 DSR Held High 1 CD Held High 5 Signal Ground DTE 2 Data 3 TX Data 7 RTS Held High 4 DTR Held High 5 Signal Ground 8 No Connect 6 No Connect 1 No Connect 2. Set W3. If you selected XW1 (DCE), Position will enable DTR (DTR controls CTS). In position C, RTS controls CTS. If you selected XW1 (DTE), all handshake leads are ignored, and W3 will have no effect. It s not necessary to set W3. If XW1 was selected, Position ------DTR* or If XW1 was selected, Position C ------RTS loops back to raise CTS or If XW1 was selected, W3 has no effect. 3. Set W2. W2 sets the delay of CTS assertion with the raising of DTR or RTS. 0 means there will be no delay. 10 gives you a 10-millisecond delay, and 30 is a 30-millisecond delay. 0------------No delay 10----------10-msec. delay 30----------30-msec. delay 10 *Factory default.

4.3 RS-485 Follow these instructions to set up the RS-485 interface. FOM LINE DRIVER ST ND SM 1. Connect the wire to the terminal block. Set the wire to T1 (the 4-wire terminal block) as indicated below for 4-wire RS-485 applications: Position 1 ------Receive positive Position 2 ------Receive negative Position 3 ------Transmit positive Position 4 ------Transmit negative For 2-wire RS-485 applications, tie Transmit negative to Receive negative and Transmit positive to Receive positive. See the illustration below. () (-) TX () TX (-) 2. Set S5. Move S5 to the RS-485 position, *. S5 determines which circuit is tied to T1. 3. Set W4, W5, and W6. For 4-wire operation: W4 and W5 are in the - position (as shipped). When configured for 4-wire, W6 is not used. For 2-wire operation: Move W4 and W5 to the -C position. W6 is now used to set the time the driver will remain enabled after the transmission of the last data bit (see below). ----------7-msec. delay ----------2-msec. delay C ----------0.7-msec. delay D ----------0.15-msec. delay 4. Set S1. If the RS-485 receiver needs to be terminated, move S1 positions 7 and 8 both ON. Note that both switches must either be ON or OFF simultaneously. To terminate: Position 7 ------1 (terminated) Position 8 ------1 (terminated) Not terminated: Position 7 ------0 (unterminated) Position 8 ------0 (unterminated) *Factory default. KEY 0 = Open/Off 1 = Closed/On 11

FOM LINE DRIVER ST ND SM 5. iased, Failsafe Operation (S1, positions 3 through 6). S1 positions 3 through 6, when in the 1 or ON position, switch in a 1K pull-up resistor to the input/output and a 1K pull-down to the input/output (see Figure 4-1). 0 is the OFF position. In almost all 2- or 4-wire RS-485 applications, positions 3 and 4 should be OFF and positions 5 and 6 should be ON. Note that positions 3 and 4 and positions 5 and 6 should always be moved in pairs, either both open or both closed. NOTE To use S1 positions 3 through 6 appropriately, you should have a firm understanding of your network requirements. Line Driver S1 Position 3 1K T1-4 TX Data Flow T1-3 1K S1 Position 4 5V S1 Position 6 1K T1-2 T1-1 Data Flow 1K S1 Position 5 5V Figure 4-1. iased/failsafe Operation Switches (RS-485). 12

4.4 20-m Current Loop (Point to Point) FOM LINE DRIVER ST ND SM NOTE To use the following switch positions appropriately, you should have a firm understanding of your network requirements. 1. Connect the wire to the terminal block. Set the wire to T1 (the 4-wire terminal block) as indicated below for 4-wire current-loop applications: Position 1 ------Receive positive () Position 2 ------Receive negative (-) Position 3 ------Transmit positive () Position 4 ------Transmit negative (-) 2. Set S5. Move S5 to the Current Loop position,. S5 determines which circuit is tied to T1. 3. Set S2 and S3. To configure the current loop transmitter and/or receiver as active or passive, set S2 and S3 as shown below. S2 20-m Current-Loop Receive --------ctive --------Passive S3 20-m Current-Loop Transmit --------ctive --------Passive 13

FOM LINE DRIVER ST ND SM 5. Quick Setup Guide XW1 = Sets the RS-232 interface for DTE XW1 = Sets the RS-232 interface for DCE W2 = RTS/CTS delay 0 10 30 ms XW2 = RS-232 interface - Loopback Switch TX W2 TX RS-232 interface (D9 connector) X W 1 X W1 Rx - Tx - 1 2 3 4 C TX Slave W3 Master TX S1 Network 20m RS-485 RS-232 W3 When the unit is set to DCE (XW1) Pos. selects CTS response to DTR Pos. C selects CTS response to RTS When the unit is set to DTE (XW1), this strap has no function S1 Pos. 1 = Mode Select 0 = Network Mode 1 = Master/Slave Mode Pos. 2 = Master/Slave Select 0 = Master 1 = Slave KEY 0 = Open/Off 1 = Closed/On Figure 5-1. Circuit board with RS-232 options. 14

FOM LINE DRIVER ST ND SM W6 When in 2-wire, this is the time that the driver remains enabled after the TX of the last data bit. Delays are: = 7 ms = 2 ms C = 0.7 ms D = 0.15 ms XW2 = RS-485 interface RS-485 Terminal lock S5 set to (RS-485) TX W6 S5 - Loopback Switch TX W5 Rx - Tx - W4 1 2 3 4 C TX Slave Master TX S1 Network 20m RS-485 RS-232 S1 KEY 0 = Open/Off 1 = Closed/On W4 and W5 Set for the position = 4 wire Set for the C position = 2 wire Pos. 1 = Mode Select 0 = Network Mode 1 = Master/Slave Mode Pos. 2 = Master/Slave Select 0 = Master 1 = Slave Pos. 3 & 4 = ias TX (see pg. 9) 0 = No ias 1 = iased Pos. 5 & 6 = ias (see pg. 9) 0 = No ias 1 = iased Pos. 7 & 8 = RS-485 Termination 0 = Unterminated 1 = Terminated Figure 5-2. Circuit board with RS-485 options. 15

FOM LINE DRIVER ST ND SM S5 set to (20m) 20-m Terminal lock XW2C = 20-m interface - Loopback Switch TX TX RS-232 Rx - Tx - 1 2 3 4 C TX Slave Master S1 S2 S3 Network 20m TX RS-485 RS-232 S1 Pos. 1 = Mode Select 0 = Network Mode 1 = Master/Slave Mode Pos. 2 = Master/Slave Select 0 = Master 1 = Slave S2 and S3 S2 Pos. = ctive S2 Pos. = Passive S3 Pos. = ctive TX S3 Pos. = Passive TX KEY 0 = Open/Off 1 = Closed/On Figure 5-3. Circuit board with 20-m current-loop options. 16

6.1 pplication Problems FOM LINE DRIVER ST ND SM If you re having a problem with your application, reread the manual. Make sure you ve selected the appropriate switches for the interface you chose. If your Line Driver is still not working properly, fill out an application diagram (found on pages 19, 21, and 23). Do this before you call for technical support. Having this information handy will help the Technical Support staff determine whether your Line Driver has been configured correctly for your application. 6.2 Calling Your Supplier If you determine that your FOM Line Driver is malfunctioning, do not attempt to alter or repair the unit. It contains no user-serviceable parts. Contact your supplier. efore you do, make a record of the history of the problem. Your supplier will be able to provide more efficient and accurate assistance if you have a complete description, including: the nature and duration of the problem. when the problem occurs. the components involved in the problem. any particular application that, when used, appears to create the problem or make it worse. 6.3 Shipping and Packaging If you need to transport or ship your Line Driver: 6. Troubleshooting Package it carefully. We recommend that you use the original container. If you are shipping the FOM Line Driver for repair, make sure you include everything that was included in the original package. efore you ship, contact your supplier to get a Return Materials uthorization (RM) number. 17

FOM LINE DRIVER ST ND SM pplication Diagram forms are found on pages 19, 21, and 23. You may be asked to fax your diagram to the Technical Support department. Use scissors to remove the page. 18

FOM LINE DRIVER ST ND SM TX TX TX TX XW2 Local Node XW2 Remote Node XW1 XW1 W3 W3 W2 W2 S5 S5 W4 W4 W5 W5 W6 W6 S2 S2 S3 S3 S1: S1: 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 NOTE 0 = Open or Off 1 = Closed or On NOTE 0 = Open or Off 1 = Closed or On 19

20 FOM LINE DRIVER ST ND SM

TX TX TX TX XW2 Local Node XW2 Remote Node XW1 XW1 W3 W3 W2 W2 S5 S5 W4 W4 W5 W5 W6 W6 S2 S2 S3 S3 S1: S1: 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 NOTE 0 = Open or Off 1 = Closed or On NOTE 0 = Open or Off 1 = Closed or On 21

22 FOM LINE DRIVER ST ND SM

TX TX TX TX XW2 Local Node XW2 Remote Node XW1 XW1 W3 W3 W2 W2 S5 S5 W4 W4 W5 W5 W6 W6 S2 S2 S3 S3 S1: S1: 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 NOTE 0 = Open or Off 1 = Closed or On NOTE 0 = Open or Off 1 = Closed or On 23

24 FOM LINE DRIVER ST ND SM

FOM LINE DRIVER ST ND SM 25

Copyright 1998. lack ox Corporation. ll rights reserved. 1000 Park Drive Lawrence, P 15055-1018 724-746-5500 Fax 724-746-0746