MANUAL MOTOR STARTERS. Ex9SN 2014 NOARK Electric

Similar documents
Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF19 and EF45

Manual motor starter MS116

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Technicaldata General

Three-phase monitoring relay CM-PFE

Safety automation solutions

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

Circuit Breakers. Next Generation of Protection Capabilities

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Manual Motor Starter MS 116 up to 16 A Technical Data

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

PSR The compact range Description

Technical catalogue. Modular DIN rail components Installation contactors

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Bimetallic Overload Relay Specifications

Catalog. Modular DIN rail components Installation contactors

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Type: DILM9 10(24VDC) Article No.:

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Rotary Disconnect Switch Specifications

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

R.C.C.B. s two-pole LEXIC

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Type: DILM32 10(24V50HZ) Article No.:

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Tmax MCCBs. Molded case circuit breakers. Tmax

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Type: DILM50(230V50HZ,240V60HZ) Article No.:

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

RM4TG20 three-phase network control relay RM4-T - range V

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ZS25 Screw Clamp Terminal Blocks Feed-through

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

Series 8146/5-V37 and Series 8150/5-V37

Power Supplies 3. SDN-P DIN Rail Series

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

Catalog January. Heavy industrial power applications Motor contactors and starters

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Thermal-Magnetic Circuit Breaker M1-..

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

8146/5 Series Breaker Panelboards

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

General information Circuit breakers for power distribution T1 T3

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Breaking and protection devices

Bulletin 1489 Circuit Breakers. Selection Guide

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Safety technique. Emergency stop module BO 5988 safemaster

NDQ5 Series. Automatic Transfer Switch. Shanghai Liangxin Electrical CO.,LTD

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

Automatic Voltage Regulator User s Manual

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Preventa Machine Safety Products

Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Plug and Socket Devices CES 63 A Series 8579

5SV Residual Current Protective Devices

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D E 0 VD00

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Products and solutions for lifting systems

GTEC transfer switch open transition

Pluggable interface relays CR-P Pcb relays

How To Operate A Gec Transfer Switch Open Transition Amp Power Supply

Unified requirements for systems with voltages above 1 kv up to 15 kv

Thermistor motor protection

D-Line Contactors, Overload Relays and Accessories

RY2 miniature industrial relays

7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units

SURGE PROTECTIVE DEVICES

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

SMS 4 / SMS 5 safety mat Product information

E-STOP relays, safety gate monitors

48 SERIES Relay interface modules 10 A

Sentron Series Circuit Breakers

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

60 Series - General purpose relays 6-10 A. Features

Relés e Contatores de Estado Sólido SIRIUS

MOTOR PROTECTIVE DEVICES

Transcription:

MANUAL MOTOR STARTERS Ex9SN 2014 NOARK Electric

Ex9SN Product Overview Features Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less against short circuit and lossphase. Nonefuss protection with a manual motor starter saves costs, space and ensures a quick reaction under shortcircuit condition, by switching off the motor within milliseconds. Manual motor starter combinations are setup together with contactors and overload relays. Available with enclosed coils for protection against particle contamination Shortcircuit protection Disconnect function P Overload protection P Lossphase protection Suitable for three and singlephase application Tripfree mechanism Clear switch position indication ON/OFF/TRIP Lockable handle F All Rights Reserved F153

Ex9SN National and International Standards Certifications IEC/EN 609472 and 6094741 CE Approved UL 508 Listed, File Number E467185, UL 609471 and 6094741A CSA Certified 22.2 No. 14 RoHS Compliant F154 2014 NOARK Electric

Ex9SN Product Selection Guide Label 1 2 3 4 5 6 1 Adjustable Current Range 2 Rated Current 3 Test Button 4 Brand 5 Product Selection 6 OFF/ON Push Buttons or Rotary Handle with Padlock F Product Selection Guide Ex9SN 25 A 0.16 A NOARK Ex9SN Series Frame Size Style Rated Current 25: 25 A A: Rotary Handle B: Pushbutton 0.16A: 0.1~0.16 A 0.25A: 0.16~0.25 A 0.4A: 0.25~0.4 A 0.63A: 0.4~0.63 A 1A: 0.63~1 A 1.6A: 1~1.6 A 2.5A: 1.6~2.5 A 4A: 2.5~4 A 6.3A: 4~6.3 A 10A: 6.3~10 A 14A: 9~14 A 18A: 13~18 A 23A: 17~23 A 25A: 20~25 A All Rights Reserved F155

Ex9SN 25 A Rotary Handle and Pushbutton Certifications IEC/EN 6094741 Rated Current Amp (MinMax) Rotary Handle 25 A Pushbutton Product Part Number Product Part Number 0.1~0.16 Ex9SN25A0.16A 1500001 Ex9SN25B0.16A 1500015 0.16~0.25 Ex9SN25A0.25A 1500002 Ex9SN25B0.25A 1500016 0.25~0.4 Ex9SN25A0.4A 1500003 Ex9SN25B0.4A 1500017 0.4~0.63 Ex9SN25A0.63A 1500004 Ex9SN25B0.63A 1500018 0.63~1 Ex9SN25A1A 1500005 Ex9SN25B1A 1500019 1~1.6 Ex9SN25A1.6A 1500006 Ex9SN25B1.6A 1500020 1.6~2.5 Ex9SN25A2.5A 1500007 Ex9SN25B2.5A 1500021 2.5~4 Ex9SN25A4A 1500008 Ex9SN25B4A 1500022 4~6.3 Ex9SN25A6.3A 1500009 Ex9SN25B6.3A 1500023 6.3~10 Ex9SN25A10A 1500010 Ex9SN25B10A 1500024 9~14 Ex9SN25A14A 1500011 Ex9SN25B14A 1500025 13~18 Ex9SN25A18A 1500012 Ex9SN25B18A 1500026 17~23 Ex9SN25A23A 1500013 Ex9SN25B23A 1500027 20~25 Ex9SN25A25A 1500014 Ex9SN25B25A 1500028 Specifications...F157 to 158 Dimensions...F159 Wiring Diagram...F160 Mounting Positions...F161 Accessories...F162 to 165 F156 2014 NOARK Electric

Ex9SN Specifications Operating Conditions Tripping Class Temperature Class 10 & 10 A 13 F to 158 F (25 C to +70 C) Average temperature in 24 hours not exceed 95 F (35 C) Altitude Not to exceed 6,562 ft (2,000 m) Air Conditions Pollution Grade Release Grade Rated Operational Frequency Mounting Conditions Rated Insulation Voltage Ui (V) At mounting site, relative humidity not exceed 50% at the max temperature of 104 F (+40 C), higher relative humidity is allowable under lower temperature Grade III 10 A (SN25) 50/60 Hz The inclination between the mounting plane and the vertical plane shall not exceed 5. The product shall be installed and operated at a place without obvious shake, impact and vibration. IEC 690 V, UL/CSA 600 V Rated Operational Voltage Ue (V) 230/340, 400/415, 440, 50, 690 Rated Impulse Withstand Voltage Uimp (V) 8,000 Overload Protection Properties Series Number Multiple of Setting Current Initial Status Time Expected Results 1 1.05 Cold Status t 2h NonTripping Ambient Temperature 2 1.20 Heat Status (right after test 1) 3 1.50 Tripping Class 4 7.20 Cold Status Tripping Class Phase Failure Protection Properties Series Number Multiple of Setting Current Any 2 Phase The Other Phase t<2h 10 A t<2 min. 10 t<4 min. 10 A 2s<t 10s 10 4s<t 10s Tripping 68 F to ±35.6 F (+20 C to ±2 C) Initial Status Time Expected Results Ambient Temperature F 1 1.0 0.9 Cold Status t 2h NonTripping 2 1.15 0 Temperature Compensation Properties Heat Status (right after test 1) t<2h Tripping 68 F to ±35.6 F (+20 C to ±2 C) Series Number Multiple of Setting Current Initial Status Time Expected Results Ambient Temperature 1 1.0 Cold Status t 2h NonTripping 2 1.2 Heat Status (right after test 1) t<2h Tripping 3 1.05 Cold Status t 2h NonTripping 4 1.3 Heat Status (right after test 1) t<2h Tripping 104 F to ±35.6 F (+40 C to ±2 C) 23 F to ±35.6 F (5 C to ±2 C) All Rights Reserved F157

Ex9SN Specifications Setting Current Range (A) 0.1~ 0.16 0.16~ 0.25 0.25~ 0.4 0.4~ 0.63 0.63~ 1 1~1.6 1.6~ 2.5 2.5~4 4~6.3 6.3~ 10 9~14 13~18 17~23 20~25 Rated Current of Release 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6.3 10 14 18 23 25 UL Ratings SinglePhase (HP) ThreePhase (HP) IEC Ratings 400/415 Vac 690 Vac 120 Vac 1/8 1/4 1/2 3/4 1 1.5 2 240 Vac 1/10 1/6 1/3 1/2 1.5 2 3 240 Vac 1/2 1 1.5 3 7.5 10 480 Vac 1 2 3 5 15 1/2 3/4 10 600 Vac 1.5 3 5 7.5 15 20 Icu (ka) 15 100 Ics % Icu 50 40 100 Icu (ka) 3 Ics % Icu 75 Rated Ultimate ShortCircuit Breaking Capacity Icu (ka) Rated Service ShortCircuit Breaking Capacity Ics (ka) Arcing Distance Standard Rated Power of Three Phase Motor (kw) 230/240 V 100 50 100 400/415 V 15 100 440 V 15 8 6 50 480/500 V 10 6 4 660/690 V 3 100 230/240 V 100 50 100 400/415 V 7.5 6 100 440 V 15 4 50 3 480/500 V 10 4.5 660/690 V 2.25 230/240 V Current Setting Value of Instantaneous Electrmagnetic Release Ir (A) Current Rating of FuseLink of Back Up Fuse, Which is Only Needed in Case of Icc>Icu (Icc: Prospective ShortCircuit Breaking Current) H: Fuse is not Required Degree of Protection 1.57 in (40 mm) 0.37 0.75 1.1 2.2 3 4 5.5 400 V 0.37 7.5 0.75 2.2 5.5 415 V 1.5 4 11 11 440 V 0.55 3 9 0.37 1.1 7.5 500 V 0.75 2.2 3.7 5.5 15 660/690 V 0.37 0.55 1.1 1.5 3 4 7.5 9 11 15 18.5 1.5 2.4 5 8 13 22.5 33.5 51 78 138 170 223 327 230/240 V am A 80 H gi/gg A 100 H am A 63 80 400/415 V gi/gg A 80 100 H am A 50 63 440 V H gi/gg A 63 80 500 V 690 V am A 50 gi/gg A 63 am A 16 25 32 40 gi/gg A 20 32 40 50 IP2L0 F158 2014 NOARK Electric

Ex9SN Dimensions Ex9SN25A Unit: in. [mm] 1.83±0.013 [46.5±0.32] 1.77±0.013 [45±0.32] 1.21±0.012 [30.8±0.30] 0.31±0.009 [8±0.24] 1.74±0.031 [44.2±0.8] 3.17±0.035 [80.5±0.9] 3.74±0.035 [94.9±0.9] 1.57 [40] 1.40±0.011 1.57 [40] [35±0.28] 1.75±0.031 [44.5±0.8] 3.50±0.028 [89±0.7] 3.60±0.028 [91.3±0.7] Ex9SN25B Unit: in. [mm] F 1.83±0.013 [46.5±0.32] 1.77±0.013 [45±0.32] 1.40±0.011 [35±0.28] 3.60±0.028 [91.3±0.7] 0.64±0.012 [16.3±0.29] 0.58±0.022 [14.8±0.55] 0.31±0.009 [8±0.24] 1.74±0.031 [44.2±0.8] 2.60±0.037 [66±0.95] 1.75±0.031 [44.5±0.8] All Rights Reserved F159

Ex9SN Wiring Diagram Ex9SN25A/B U V U V W 2T1 4T2 6T3 2T1 4T2 6T3 2T1 4T2 6T3 1L1 3L2 5L3 1L1 3L2 5L3 1L1 3L2 5L3 L N M U V W M M Operating principle diagram of starter Principle connection diagram of starters and contactors Principle connection diagram of singlephase or DC motor F160 2014 NOARK Electric

Ex9SN Accessories: Auxiliary Contact and Enclosure ASN A 11 Description Manual Motor Starter Accessory Type A: Auxiliary Contact Side Mount B: Auxiliary Contact Front Mount F: Auxiliary Contact with Fault Signal Contact Auxiliary Contact 11: 1NO+1NC 20: 2NO 1001: 1NO (Fault)+ 1NC (Auxiliary) 0101: 1NC (Fault)+ 1NC (Auxiliary) ASNA ASNB 1010: 1NO (Fault)+ 1NO (Auxiliary) 0110: 1NC (Fault)+ 1NO (Auxiliary) Accessory Description Type Product Part Number ASNA11 1500030 Side Mount ASNA20 1500029 ASNB11 1500032 Front Mount ASNB20 1500031 Auxiliary Contact ASNF1001 1500041 ASNF0101 1500042 Fault Signal Contact ASNF1010 1500043 ASNF0110 1500044 F ASNF Specifications... F163164 Dimensions... F165 ASN EA Description Manual Motor Starter Accessory Type EA: Enclosure with Actuating Diaphragm ASNEA EB: Enclosure with Emergency Stop Pushbutton ASNEB Accessory Description Product Part Number 1500045 ASNEA Enclosure 1500046 ASNEB Specifications... F163164 Dimensions... F166 All Rights Reserved F161

Ex9SN Accessories: Shunt Trip and UnderVoltage Release ASN T A Description Manual Motor Starter Accessory Type T: Shunt Trip Release Rated Voltage A: 110~115 Vac 50 Hz 127 V 60 Hz B: 220~240 Vac 60 Hz C: 380~400 Vac 50 Hz 440 V 60 Hz D: 380~400 Vac 60 Hz Specifications... F163164 Dimensions... F165 Accessory Description Product Part Number Shunt Trip Release (Side Mount) ASNTA 1500037 ASNTB 1500038 ASNTC 1500039 ASNTD 1500040 ASN UV A Description Manual Motor Starter Accessory Type UV: UnderVoltage Release Rated Voltage A: 110~115 Vac 50 Hz 127 V 60 Hz B: 220~240 Vac 60 Hz C: 380~400 Vac 50 Hz 440 V 60 Hz D: 380~400 Vac 60 Hz Specifications... F163164 Dimensions... F165 Accessory Description Product Part Number Under Voltage Release (Side Mount) ASNUVA 1500033 ASNUVB 1500034 ASNUVC 1500035 ASNUVD 1500036 F162 2014 NOARK Electric

Ex9SN Accessory Specifications UL File Number UL Ratings Side Mount Auxiliary Contact Front Mount Electrical Contact Type B600 D300 Fault Signal Contact Actuating Diaphragm Enclosure Emergency Stop Pushbutton Shunt Trip Release Under Voltage Release ASNA ASNB ASNF ASNEA ASNEB ASNT ASNUV Fault: D300 Auxiliary: B600 E467185 Rated Insulation Voltage Ui (V) 690 250 690 690 Voltage Range of Operation 35~70% Ue 70~110% Ue Ue Max (V) 690 250 Conventional Heating Current Ith (A) 6 2.5 AC15 720 Vac 240 V 120 Vac 240 V Fault: 240 Auxiliary: 690 Fault: 2.5 Auxiliary: 6 Fault: 720 Vac/240 V Auxiliary: 720 Vac/240 V IEC File Number IEC/EN 6094751 IEC/EN 609472 IEC Ratings PickUp Voltage (Un) 0.7~1.1 0.85~1.1 DropOff Voltage (Un) 0.75~0.2 0.7~0.35 IP Class IP 55 IP 55 F All Rights Reserved F163

Ex9SN Accessory Specifications Side Mount Auxiliary Contact Front Mount Fault Signal Contact ASNA ASNB ASNF Utilization Category AC15 AC14 Rated Operational Current Ie (A) Normal Operational Power P (W) 24 Vac 2 1.5 48 Vac 6 1.25 1 110/127 Vac 4.50 1 0.50 230/240 Vac 3.30 0.50 0.30 380/415 Vac 2.20 440 Vac 1.50 500 Vac 1 690 Vac 0.60 DC13 24 Vdc 6 1 48 Vdc 5 0.30 60 Vdc 3 0.15 110 Vdc 1.30 220 Vdc 0.50 AC15 24 Vac 48 36 48 Vac 300 60 48 110/127 Vac 500 127 230/240 Vac 720 120 380/415 Vac 850 440 Vac 650 500 Vac 500 690 Vac 400 DC13 24 Vdc 140 24 48 Vdc 240 15 60 Vdc 180 9 110 Vdc 140 220 Vdc 120 Operational Features (Times) 1,000 72 Auxiliary Contact Fault Signal Contact ASNF Utilization Category AC14 AC15 DC13 Connection I/Ie 6 10 U/Ue 1.10 1.10 Cos ø or t 0.95 0.70 0.30 6 Pe I/Ie 6 10 1.10 Disconnection U/Ue 1.10 Cos ø or 0.70 0.30 6 Pe t 0.95 Number of On/Off Operation Cycles and Operation Frequency Number of Operation Cycles Number of Operation Cycles Per Minute On Power Time 10 2 0.05 F164 2014 NOARK Electric

Ex9SN Accessory Dimensions Manual Motor Starter with Accessories Unit: in. [mm] Auxilary Contact Side Mount Auxilary Contact Side Mount & Fault Signal Contact Shunt Trip Release & Under Voltage Release Auxilary Contact Side Mount Auxilary Contact Side Mount & Fault Signal Contact Shunt Trip Release & Under Voltage Release Auxilary Contact Front Mount Auxilary Contact Front Mount 0.38 [9.5] 0.43 [11] 0.38 [9.5] 0.43 [11] 0.37 0.37 [9.3] [9.3] 3.19 [81.1] 0.71 [18] 0.37 0.37 [9.3] [9.3] 3.19 [81.1] 0.71 [18] F All Rights Reserved F165

Ex9SN Accessory Dimensions ASNEA Enclosure with Actuating Diaphragm Unit: in. [mm] 0.21 [5.4] ø0.25 ø[6.3] 3.63 [92.2] 3.69 [93.8] 3.52 [89.3] 0.21 [5.4] 5.12 [130] 5.8 [147.6] ASNEB Enclosure with Emergency Stop Pushbutton Unit: in. [mm] 0.21 [5.4] ø0.25 [ø6.3] 3.63 [92.2] 5.99 [152.3] 3.52 [89.3] 0.21 [5.4] 5.12 [130] 5.8 [147.6] F166 2014 NOARK Electric

F All Rights Reserved F167

NOARK Electric North America (626) 3307007 www.noarkusa.com NASales@NoarkElectric.com Note: NOARK Electric reserves the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. NOARK Electric does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. NOARK Electric reserves all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of NOARK Electric. 2014 NOARK Electric All Rights Reserved CCR201401NA