Installation Guide. TH7000 Series. Need Help? This manual covers the following models. System Types

Similar documents
Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Installation Guide. Programmable Thermostat TH6220D

Installation Instructions

COMFORT CONTROL - 4 HEAT (GAS, OIL*, OR ELECTRIC)/3 COOL/HEAT PUMP COMMUNICATING PROGRAMMABLE 3 WIRE HOOKUP

UP400 Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Honeywell CT3500/CT3595 PROGRAMMABLE THERMOSTAT

HEAT PUMP PROGRAMMABLE THERMOSTAT

1F Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

CT3200 Programmable Thermostat

Installation Instructions

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

1F /1/1 Day Programmable. 1F Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1

HEAT HEAT COOL HEAT PUMP COOL

How To Control A Thermostat

Install Guide CT101. Caution. Caution

APPLICATIONS SPECIFICATIONS CAUTION. Blue Universal Thermostat with Automatic Heat/Cool Changeover Option. Save these instructions for future use!

Table of Contents. 1 - Specifications Installation Wiring User controls...7

QUICK INSTALLATION GUIDE

UV100A Ultraviolet Air Treatment System

ACONT900AC43UA Communicating, Programmable Comfort Control

Professional Contractor INSTALLATION GUIDE

Communicating Wall Control Installation Manual TSTAT0101SC

Install Guide 3M-50. Caution. Caution

Installation Guide. Prestige IAQ with Equipment Interface Module. RedLINK to Equipment Interface Module. RedLINK to TrueZONE Wireless Adapter

WHITE-RODGERS COMFORT-SET 90 SERIES

Operating Manual. Prestige THX9000 Touch-screen Thermostat Thermostat à écran tactile Termostato con pantalla táctil

Mode Switch. Fan Switch Menu button Program button

T-100-R Installation Guide

VisionPRO 8000 with RedLINK

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

SINCE AUTO SAVER 550. OwnerÕs Manual Model 44550

1 For All Non-Programmable Digital Thermostat

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Alerts and Delta T Diagnostics with the Prestige 2.0 IAQ Thermostat

Operation Guide 3M-22

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

User Manual THR840DUK Digital Thermostat

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

YOUR THERMOSTAT REPLACES Assemble tools required as shown below. HAND OR POWER DRILL WITH 3/16 INCH DRILL BIT, IF NEEDED

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

INSTALLATION REMOVE OLD THERMOSTAT ATTACH THERMOSTAT BASE TO WALL CHECK THERMOSTAT OPERATION BATTERY LOCATION

PSPA711a. LUXPRO PSPA711a INSTALLATION AND OPERATING INSTRUCTIONS. Mt. Laurel, New Jersey 08054, USA

RedLINK Wireless Comfort Systems. RedLINK Connects.

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

The Totaline Premier Series of thermostats consists of programmable and non programmable air conditioner, heat pump and thermidistat control.

Wireless and Prestige Comfort Systems. Frequently Asked Questions Guide

User Guide. VisionPRO Wi-Fi Programmable Thermostat. Model TH8320WF

Heating and Cooling Basics Thermostat Control

T7560A,B,C Digital Wall Module

Technical support is also available by or by phone: (North America) (International)

General Information. Do programmable thermostats really save energy?

UV100E Ultraviolet System

1F Day 5/1/1 Day Non-Programmable. Yes

ComfortLink II Installation Guide. 3 Zone Panel (optional) 4 Zone Sensor with Display (optional) 5 Zone Sensor (optional) 6 Zone Dampers (optional)

Drayton Digistat +2RF/+3RF

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Nest Learning Thermostat Pro installation & configuration guide

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

NOTE: Append this Operation IB to the Install IB to make one IB-booklet. Need a divider tab between the 2 sections. Blank page remove.

Blue Easy Reader Thermostat 1F95EZ Homeowner s Guide

REMOTE CONTROL MANUAL

Wireless Solutions. Application Selection Guide

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

SC Installation, Operation & Application Guide

Safety & Installation Instructions

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Installation Questions

T6861 Series Large LCD Digital Thermostat 110/220 VAC 2-pipe/4-pipe fan coil control

RESIDENTIAL THERMOSTATS CLIMATEMASTER

Programmable Thermostat

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

T841A Heating-Cooling Heat Pump Thermostat

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

FOXAIR 60/50 ALL MODELS

W8735B Telephone Access Module

INSTALLATION INSTRUCTIONS

CONTROLS KITS AND ACCESSORIES /2014 Supersedes10/2014

T7079A,B Solid State Remote Temperature Controllers

INSTALLER S SYSTEM SETUP GUIDE

EK908FHL - Thermostat for floor heating

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

Nexus FS Point of Use Installation Guide

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

1 PREPARATIONS 2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT. 1E78 5/2 Day Programmable Thermostat CONTENTS CAUTION. Installation Instructions for

Instruction manual for Firstline FCS12000CH

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

1F78 CAUTION CONTENTS YOUR THERMOSTAT REPLACES PREPARATIONS. Installation Instructions for. Heating & Air Conditioning. Non-Programmable Thermostat

T8000, T8001 Programmable Thermostat

Manual & Technical Documentation V1.1

Transcription:

Installation Guide TH7000 Series Touch-screen Programmable Thermostat This manual covers the following models TH7220U: For up to 2 Heat/1 Cool Heat Pumps or 2 Heat/2 Cool Conventional systems (Pull thermostat from wallplate and turn over to find model number) System Types Gas, oil, or electric heat with air conditioning Warm air, hot water, highefficiency furnaces, heat pumps, steam, gravity Heat only two-wire systems, power to open and close zone valves (Series 20), and normallyopen zone valves Heat only with fan Cool only 750 mv heating systems This thermostat contains a Lithium battery which may contain Perchlorate material. Perchlorate Material special handling may apply, See www.dtsc.ca.gov/hazardouswaste/perchlorate Need Help? For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502 U.S. Registered Trademark. US Patents pending. Copyright 2011 Honeywell International Inc. All rights reserved. 69-2668-03

Installation Guide Wallplate installation 1. Separate wallplate from thermostat. 2. Mount wallplate as shown below. Grasp top and bottom of wallplate and pull to remove from thermostat. Drill 3/16 holes for drywall. Drill 7/32 holes for plaster. M28073 Wire hole Mounting screws Wall anchors Must be installed by a trained, experienced technician Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition. CAUTION: ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect power before beginning installation. MERCURY NOTICE If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact your local waste management authority for instructions regarding recycling and proper disposal. 69-2668 03 2

Power options For 24VAC primary power, connect common side of transformer to C terminal. TH7000 Series C G Y O/B RC R C G Y W RC R W2 Y2 NOT USED S1 S2 AUX E L S1 S2 CONVENTIONAL HEAT PUMP MCR31515 Insert supplied batteries for primary or backup power. Wiring Remove factory-installed jumper only for two-transformer systems. SCREW INSERT WIRES THEN TIGHTEN SCREWS WIRE HOLE Push excess wire back into the wall opening. Plug wall opening with non-flammable insulation. C G Y O/B RC R C G Y W RC R W2 Y2 NOT USED S1 S2 AUX E L S1 S2 CONVENTIONAL HEAT PUMP Terminal Designations MCR31517 Conventional Terminal Letters: R Heating power. Connect to secondary side of heating system transformer. Rc Cooling power. Connect to secondary side of cooling system transformer. C Common wire from secondary side of cooling transformer (if 2 transformers). W 1st stage heat relay. W2 2nd stage heat relay. Y 1st stage compressor contactor. Y2 2nd stage compressor contactor.. S1 Optional outdoor or remote sensor. S2 Optional outdoor or remote sensor. Heat Pump Terminal Letters: R Heating power. Connect to secondary side of heating system transformer. Rc Cooling power. Connect to secondary side of cooling system transformer. C Common wire from secondary side of cooling system transformer. Y 1st stage compressor contactor. Aux Auxiliary heat relay.. E Emergency heat relay. L Heat pump reset (powered continuously when System is set to Em Heat; system monitor when set to Heat, Cool or Off). O/B Changeover valve for heat pumps. S1 Optional outdoor or remote sensor. S2 Optional outdoor or remote sensor. 3 69-2668 03

Installation Guide Wiring 1H/1C System (1 transformer) W Heat relay Y Compressor contactor Wiring guide conventional systems 1H/1C System (2 transformers) Rc Power (cooling transformer) [1, 2] R Power (heating transformer) [1, 2] W Heat relay Y Compressor contactor C 24VAC common [3, 4] Heat Only System W Heat relay Heat Only System (Series 20) Rc [R+Rc joined by jumper] R Series 20 valve terminal R [1] W Series 20 valve terminal B Y Series 20 valve terminal W 2H/2C System (1 transformer) Y2 Cool relay 2 W2 Heat relay 2 W Heat relay 1 Y Cool relay 1 Heat Only System With Fan W Heat relay Cool Only System Y Compressor contactor 2H/2C System (2 transformers) Y2 Cool relay 2 W2 Heat relay 2 Rc Power (cooling transformer) [1, 2] R Power (heating transformer) [1, 2] W Heat relay 1 Y Cool relay 1 C 24VAC common [3, 4] See [notes] below [1] Power supply. Provide disconnect means and overload protection as required. [2] Remove jumper for 2-transformer systems. [3] Optional 24VAC common connection. [4] Common connection must come from cooling transformer. 69-2668 03 4

Wiring 1H/1C Heat Pump (no auxiliary heat) O/B Changeover valve [5] Y Compressor relay Wiring guide heat pump systems TH7000 Series 2H/1C Heat Pump (with auxiliary heat) L Equipment monitor [6, 7] E Emergency heat relay [8] Aux Auxiliary heat relay (Heat 2) [8] O/B Changeover valve [5] Y Compressor relay See [notes] below [1] Power supply. Provide disconnect means and overload protection as required. [3] Optional 24VAC common connection. [5] O/B set to control as either O or B in installer setup. [6] If L terminal is used, 24VAC common (terminal C) must be connected. [7] Heat pump reset (powered continuously when thermostat is set to Em. Heat; system monitor when set to Heat, Cool, or Off). [8] Install field jumper between Aux and E terminals if there is no emergency heat relay. Remove tab and mount thermostat Remove tab. M27518 Align pins on back of thermostat with slots in wallplate, then push gently until thermostat snaps into place. M27519 5 69-2668 03

Installation Guide Set date and time Press st to set month, then press NEXT Repeat to set year and then day of month 6 2012 15 Go Back Next Done Press st to set time 10:10 Done Press DONE to save changes. MCR31518 M27521 Press DONE to save and exit. Installer setup 1. Press SYSTEM & FAN. 2. Press and hold the SYSTEM and DONE buttons until the display changes. System & Fan 3. Change settings as required (see pages 7-9). System Fan Done MCR31510 0120 20 Go Back Next Done Press s/t to change setting Press NEXT to advance to next function. Press DONE to exit and save changes. MCR31511 69-2668 03 6

TH7000 Series Setup functions 0120 Year (first two digits) 0130 Year (second two digits) 20 (2000-2099) 21 (2101-2178) 12 (2012) [Other options: 00-99] 0140 Month 6 [Other options: 1-12] 0150 Date 15 [Other options: 1-31] 0160 Schedule format 4 7-day programming 0 Non-programmable 0165 Restore energy saving schedule 0 Continue using programmed schedule. 1 Restore thermostat program to energy saving settings. 0170 System type 1 1 heat/1 cool conventional 2 1 heat/1 cool heat pump (no aux. heat) 3 Heat only (2-wire systems) 4 Heat only with fan 5 Hot water Series 20 system (power to open & close zone valves/normally open zone valves) 6 Cool only 7 2 heat/1 cool heat pump (with aux. heat) 8 2 heat/2 cool multistage conventional 9 2 heat/1 cool multistage conventional 10 1 heat/2 cool multistage conventional 0180 Fan control (heating) 0190 Changeover valve (O/B terminal) 0 Gas/Oil heat (equipment controls heating fan) 1 Electric furnace (thermostat controls heating fan) 0 O/B terminal controls valve in cooling 1 O/B terminal controls valve in heating 0200 Auxiliary heat 0 Electric backup heat 1 Fossil fuel backup heat 0210 External fossil fuel kit 0220 1st stage compressor cycle rate 0230 2nd stage compressor cycle rate Settings & Options (factory default in bold) 1 External fossil fuel kit controls backup heat 0 Thermostat controls backup heat (outdoor sensor required) 3 Recommended for most compressors [Other options: 1, 2, 4, 5 or 6 CPH] 3 Recommended for most compressors [Other options: 1, 2, 4, 5 or 6 CPH] Continued on next page 7 69-2668 03

Installation Guide Installer setup Setup functions 0240 First stage heat cycle rate (CPH= cycles per hour) 0250 Second stage heat cycle rate (CPH) 0270 Emergency heat cycle rate (CPH) 5 Gas or oil furnaces of less than 90% efficiency 1 Steam or gravity systems 3 Hot water systems & furnaces of 90%+ efficiency 9 Electric furnaces [Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH] 5 Gas or oil furnaces of less than 90% efficiency 1 Steam or gravity systems 3 Hot water systems & furnaces of 90%+ efficiency 9 Electric furnaces [Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH] 9 Electric emergency heat 1 Steam or gravity systems 3 Hot water systems & furnaces of 90%+ efficiency 5 Gas or oil furnaces of less than 90% efficiency [Other options: 2, 4, 6, 7, 8, 10, 11, 12 CPH] 0280 Backlight 0 Backlight on for approx. 8 seconds after keypress 1 Backlight always on low intensity, full bright after keypress (requires 24VAC connection) 0300 Manual/Auto changeover 0310 Auto changeover deadband 0320 Temperature display 0 Manual changeover (Heat/Cool/Off) 1 Automatic changeover (Heat/Cool/Auto/Off) 3 Heat/cool temperature 3 F apart (1.5 C) ** See page 11 [Other options: 2-9 (2 F to 9 F/1 C to 5 C)] 0 Fahrenheit 1 Celsius 0330 Daylight savings 2 Auto-change to daylight savings time (2007 and beyond, for areas that use the new 2007 DST calendar) 1 Auto-change to daylight savings time (through 2006, and for areas that do not use the new 2007 DST calendar) 0 Daylight savings time is turned off 0340 Remote sensor 0 No remote sensor 1 Outdoor sensor (display only) 2 Outdoor control sensor (select heat pumps) ** See page 11 3 Indoor sensor 0350 Heat pump compressor lockout 0360 Heat pump auxiliary lockout Settings & Options (factory default in bold) 0 No heat pump compressor lockout Other options: 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60 F (-15 C to 15.5 C) 0 No heat pump auxiliary lockout Other options: 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65 F (-15 C to 18.5 C) Continued on next page 69-2668 03 8

Installer setup TH7000 Series Setup functions Settings & Options (factory default in bold) 0500 Furnace filter change reminder 0510 Humidifier pad change reminder 0520 UV lamp change reminder 0530 Adaptive Intelligent Recovery 0 Off 1 10-day run time (about 1 month) 2 30-day run time (about 3 months) 3 60-day run time (about 6 months) 4 90-day run time (about 9 months) 5 120-day run time (about 1 year) 6 365-day run time (about 3 years) 0 Off 1 90 calendar days 2 180 calendar days 3 365 calendar days 0 Off 1 365 calendar days 1 On ** See page 11 0 Off 0540 Program periods 4 4 program periods (Wake, Leave, Return, Sleep) 2 2 program periods (Wake, Sleep) 0580 Compressor protection 0600 Heat temperature range stop 0610 Cool temperature range stop 5 5 minute compressor off time ** See page 11 [Other options: 0, 1, 2, 3 or 4-minute off time] 90 Max. heat temperature setting is 90 F (32 C) [Other options: 40-89 F (4 C to 32 C)] 50 Min. cool temperature setting is 50 F (10 C) [Other options: 51-99 F (11 C to 37 C)] 0640 Clock format 12 12-hour time (i.e., 3:30 pm ) 24 24-hour time (i.e., 15:30 ) 0650 Extended fan timer (heat) 0660 Extended fan timer (cool) 0 Off 90 Fan runs for 90 seconds after call for heat ends 0 Off 90 Fan runs for 90 seconds after call for cooling ends 0670 Keypad lock 0 Keypad unlocked (fully functional) 1 Partially locked (access to temperature settings only) 2 Fully locked 0680 Heat temperature control 0690 Cool temperature control 0700 Temperature display offset 2 Standard temperature control (recommended) 1 Choose if room is warmer than set temperature 3 Choose if room does not reach set temperature 2 Standard temperature control (recommended) 1 Choose if room is cooler than set temperature 3 Choose if room does not reach set temperature 0 Thermostat displays actual room temperature [Other options: -3, -2, -1, 1, 2, 3 F offset (-1.5 C to 1.5 C) 0710 RESET 0 No reset 1 Reset installer options & program schedule to factory default (only date and time settings are retained) 9 69-2668 03

Installation Guide Installer system test Once you enter installer setup, press the Go Back button repeatedly until Test 1 appears. 0120 20 Go Back Next Done MCR31511 Test number System status 1 es EEEE 0 Go Back Next Done Press st to change status Press Next to select next test. MCR31520 Press DONE to exit testing. System test System status 1 Cooling system 0 Compressor and fan turn off 1 Compressor and fan turn on 2 Second stage compressor turns on 2 Fan system 0 Fan turns off 1 Fan turns on 3 Heating system 0 Heat and fan turn off 1 Heat turns on (fan on if Function 0170 is set for heat pump, or if Function 0180 is set to 1 ) ** See page 6 2 Second stage heat turns on 4 Emergency heating system 0 Heat and fan turn off 1 Heat and fan turn on 2 Second stage heat turns on (Auxiliary heat)] CAUTION: EQUIPMENT DAMAGE HAZARD. Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly. 69-2668 03 10

Special functions TH7000 Series Auto Changeover (Setup Function 0300): When set to Auto, the thermostat automatically selects heating or cooling depending on the indoor temperature. Heat and cool settings must be at least 2 degrees apart. If function 0380 is set to On, the heat and cool settings must be at least 5 degrees apart. Remote Sensor (Setup Function 0340): If an optional outdoor sensor is installed, the thermostat can display the outside temperature. If an optional remote indoor sensor is installed, the thermostat will display the temperature at the sensor location (the internal sensor in the thermostat is not used). Adaptive Intelligent Recovery (Setup Function 0530): Allows the thermostat to learn how long the furnace and air conditioner take to reach programmed temperature settings, so the temperature is reached at the scheduled time. Compressor Protection (Setup Function 0580): Forces the compressor to wait a few minutes before restarting, to prevent damage. During this time, the message Wait flashes on the display. Heat Pump Temperature Lockout (with fossil-fuel backup): If the thermostat is installed with an optional outdoor sensor, you can select a compressor lockout temperature (Function 0350). When the outdoor temperature is below the lockout temperature, only the auxiliary heat operates. When the outdoor temperature is above the lockout temperature, only the compressor operates. Heat Pump Temperature Lockouts (with electric heat backup): If the thermostat is installed with an optional outdoor sensor, you can select a compressor lockout temperature (Function 0350) and/or an auxiliary heat lockout temperature (Function 0360). When the outdoor temperature is below the compressor lockout temperature, only the auxiliary heat operates. When the outdoor temperature is above the auxiliary lockout temperature, only the compressor operates. If the outdoor temperature is between the compressor and auxiliary lockout temperatures, both the compressor and auxiliary heat can operate. Accessories & replacement parts Please contact your distributor to order replacement parts. Outdoor temperature sensor... Part Number C7089U1006 Remote indoor temperature sensor... Part Number C7189U1005 Cover plate*... Part Number 50002883-001 *(Use to cover marks left by old thermostats.) 11 69-2668 03

Installation Guide Specifications Temperature Ranges Heat: 40 to 90 F (4.5 to 32 C) Cool: 50 to 99 F (10 to 37 C) Operating Ambient Temperature 0 to 120 F (-18 to 48.9 C) Shipping Temperature -30 to 150 F (-34 to 66 C) Operating Relative Humidity 5% to 90% (non-condensing) Physical Dimensions 3-3/4 H x 6 W x 1-3/8 D 99 mm H x 152 mm W x 35 mm D Electrical Ratings Terminal Voltage (50/60Hz) Running Current W Heating 20-30 Vac 0.02-1.0 A (Powerpile) 750 mv DC 100 ma DC W2 Heating 20-30 Vac 0.02-0.6 A Y Cooling 20-30 Vac 0.02-1.0 A Y2 Cooling 20-30 Vac 0.02-0.6 A Aux Auxiliary heat 20-30 Vac 0.02-1.0 A O/B Changeover 20-30 Vac 0.02-0.6 A L Heat pump reset 20-30 Vac 0.02-0.6 A Need Help? For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502 Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 http://customer.honeywell.com U.S. Registered Trademark. US Patents pending. 2011 Honeywell International Inc. 69-2668 03 M.S. 10-11 Printed in U.S.A.