Hitachi Ion Milling System

Similar documents
Ion Beam Sputtering: Practical Applications to Electron Microscopy

Coating Technology: Evaporation Vs Sputtering

Lecture 12. Physical Vapor Deposition: Evaporation and Sputtering Reading: Chapter 12. ECE Dr. Alan Doolittle

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater

Laser beam sintering of coatings and structures

Vacuum Evaporation Recap

VCR Ion Beam Sputter Coater

Defects Introduction. Bonding + Structure + Defects. Properties

7. advanced SEM. Latest generation of SEM SEM

Lapping and Polishing Basics

VICKERS HARDNESS TESTER. HBS HBW Kc

M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

Profile Projector PH-3500

View of ΣIGMA TM (Ref. 1)

h e l p s y o u C O N T R O L

Dry Film Photoresist & Material Solutions for 3D/TSV

1.Introduction. Introduction. Most of slides come from Semiconductor Manufacturing Technology by Michael Quirk and Julian Serda.

PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES PORTABLE MICROSCOPES

08. SEK IDC CONNECTORS

The Basics of Scanning Electron Microscopy

Miniaturizing Flexible Circuits for use in Medical Electronics. Nate Kreutter 3M

BGA - Ball Grid Array Inspection Workshop. Bob Willis leadfreesoldering.com

Solid shape molding is not desired in injection molding due to following reasons.

Attenuation: Bending Loss

NARROW-PITCH (0.8mm) CONNECTORS P8 SERIES

CHAPTER-3: EXPERIMENTAL PROCEDURE

Material data sheet. EOS CobaltChrome MP1. Description

Secondary Ion Mass Spectrometry

NANO INDENTERS FROM MICRO STAR TECHNOLOGIES

Fast Z-stacking 3D Microscopy Extended Depth of Field Autofocus Z Depth Measurement 3D Surface Analysis

HSeries. High Power High Quality. Ultra-High Speed, Sensing Ionizer SJ-H Series

Laser sintering of greens compacts of MoSi 2

Difference Between Various Sn/Ag/Cu Solder Compositions. Almit Ltd. Tadashi Sawamura Takeo Igarashi

Electron Beam and Sputter Deposition Choosing Process Parameters

Development of High-Speed High-Precision Cooling Plate

1. Photon Beam Damage and Charging at Solid Surfaces John H. Thomas III

STAVAX SUPREME. Stainless tool steel

UV100A Ultraviolet Air Treatment System

SPECIFICATION Aluminum Module Frames. Allowed anodization before fabrication for clear frames.

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

, Yong-Min Kwon 1 ) , Ho-Young Son 1 ) , Jeong-Tak Moon 2 ) Byung-Wook Jeong 2 ) , Kyung-In Kang 2 )

microscope OP-Dent-5

Compliant Terminal Technology Summary Test Report

Three Channel Optical Incremental Encoder Modules Technical Data

Espotel Test Laboratory Services. November 20, 2014

Structural Integrity Analysis

Reflectance Characteristics of Accuflect Light Reflecting Ceramic

X-RAY TUBE SELECTION CRITERIA FOR BGA / CSP X-RAY INSPECTION

Think precision, Think HSS REAMING

INFRARED MONITORING OF 110 GHz GYROTRON WINDOWS AT DIII D

Traditional Drawing Tools

X-ray diffraction techniques for thin films

Nanometer-scale imaging and metrology, nano-fabrication with the Orion Helium Ion Microscope

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

For board-to-fpc. Narrow Pitch Connectors (0.35mm pitch)

Polymer Termination. Mechanical Cracking 2. The reason for polymer termination. What is Polymer Termination? 3

Development of New Inkjet Head Applying MEMS Technology and Thin Film Actuator

CHARACTERIZATION OF POLYMERS BY TMA. W.J. Sichina, National Marketing Manager

Guideline Laser Series

Hygro-Thermometer + InfraRed Thermometer Model RH101

Material data sheet. EOS StainlessSteel GP1 for EOSINT M 270. Description, application

Be careful not to scratch or hit front edge of the side viewing micro prisms onto hard objects!

Basic Properties and Application Examples of PGS Graphite Sheet

The quadrature signals and the index pulse are accessed through five inch square pins located on 0.1 inch centers.

Directory chapter 04

Pin & Vee Block Test Machine

DualBeam Solutions for Electrical Nanoprobing

A new advance in routine inspections INVERTED MICROSCOPE CKX41/CKX31

Making Better Medical Devices with Multisensor Metrology

BAL-TEC SCD 005. Scientist in charge: Lhoussaine Belkoura 07/14/06. softcomp soft matter composites 1

AMPSEAL* Automotive Plug Connector and Header Assembly

HSMtec. Intelligent Printed Circuit Boards for innovative LED products. Copyright, Häusermann GmbH, 2012

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

Demonstration of sub-4 nm nanoimprint lithography using a template fabricated by helium ion beam lithography

Planar Magnetron Sputtering Sources

How To Design A 3D Print In Metal

Standard Specification for Flat Glass 1

Evaluating Surface Roughness of Si Following Selected Lapping and Polishing Processes

ENIG with Ductile Electroless Nickel for Flex Circuit Applications

Preface Light Microscopy X-ray Diffraction Methods

GP2Y0D810Z0F. Distance Measuring Sensor Unit Digital output (100 mm) type GP2Y0D810Z0F

Embedding components within PCB substrates

Conductivity of silicon can be changed several orders of magnitude by introducing impurity atoms in silicon crystal lattice.

li-ion Polymer Battery Specification

ADVANCED DIRECT IMAGING. by ALTIX

%Ï51,75,' 6=(56=È02. 'LDPRQG DQG &%1 WRROV

Evaluation of Soft Soldering on Aluminium Nitride (AlN) ESTEC Contract No /05/NL/PA. CTB Hybrids WG ESTEC-22nd May 2007

MEASURING AND LEVELING TOOLS

AISI CHEMICAL COMPOSITION LIMITS: Nonresulphurized Carbon Steels

GP2Y0A02YK0F. Distance Measuring Sensor Unit Measuring distance: 20 to 150 cm Analog output type GP2Y0A02YK0F

Gas Meter Clearances and Service Installation Requirements

Material data sheet. EOS Aluminium AlSi10Mg_200C. Description

Material data sheet. EOS Aluminium AlSi10Mg. Description

Removing chips is a method for producing plastic threads of small diameters and high batches, which cause frequent failures of thread punches.

Winbond W971GG6JB-25 1 Gbit DDR2 SDRAM 65 nm CMOS DRAM Process

Flanged and Butt-= Weld Type

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Transcription:

Flat Milling Observation via SEM of metallographic microstructures or defects of various materials requires special sample preparation. Traditional mechanical sample preparation via grinding and polishing can result in deformation, flaws, and artifacts that obscure the true structure of the material. Hitachi offers an ion milling system that can eliminate mechanical stress to the sample. The IM4000 can quickly and effectively provide a damage-less flat milling method to enhance mechanically prepared materials. Cross-section Milling High quality preparation of structures below the sample surface for SEM observation is common method often reserved for focused ion beam systems. Other alternatives for preparing cross-sections rely on mechanical or cleaving methods which often distort or induce damage. The Hitachi IM4000 Ion Milling System utilizes a broad, low-energy Ar+ ion beam milling method to produce wider undistorted cross-sections without applying mechanical stress to the sample. Processing Principle Major Features and Applications Processing Principle Major Features and Applications Schematic diagram for processing of Flat milling The ion beam exhibits a Gaussian shaped current density profile. When the ion beam center coincides with the sample rotation center, the center of the sample material is removed at a higher rate than the surrounding area. As the sample rotation and swing center are varied with respect to the ion beam center, a wide-area can be sputtered with increased uniformity. Approximately 5 mm in diameter can be ion-milled uniformly Eliminate flaws and artifacts from traditional mechanical grinding and polishing techniques Diverse range of materials applicable to flat ion milling Observation of crystal grain boundaries and multi-layer films Relief ion milling by sputtering perpendicular to the sample surface can enhance topography of composite based materials or crystal orientation for observation. Interface observation, X-ray analysis, and EBSP analysis Flat ion milling at an oblique angle minimizes the dependence between sputtering rate and crystal orientation, yielding reduced surface topography and a flatter sample surface. Allowable sample size up to 50mm in diameter x 25mm height Multi-function stage Multiple rotation speeds and stage oscillation modes provide even greater control to reduce artifacts and sputter flatter surfaces for difficult materials. EBSP Electron Back Scattering Pattern Schematic diagram for processing of Cross-section milling A mask is placed directly on top of the sample, which is not only used for protecting the top surface but also provides a sharp edge to create a damage-less flat cross-section face by sputtering away material that is exposed beyond the masked edge. High quality damage-less cross-section for the analysis of structures below the surface examples: Electronic components such as IC chips, PCB, IC cards, LED (analysis of layers, interconnects, cracks, voids), metals (EBSD grain structure, EDS elemental analysis, coatings), polymers, papers, ceramics and glasses, pharmaceutical drugs, powders etc. Removable sample stage unit for bench top optical alignment of sample and for site specific ion milling (see explanation below) s with maximum dimensions of 20mm wide x 12mm square x 7mm thick can be milled. stub compatibility eliminates the need to change mounts between mechanical polishing, ion milling, and SEM observation (Hitachi models) Maruto polisher (option) 1 2

Example Application Data (Flat Milling) Grinding flaws and smearing from mechanical polishing can easily be removed by the IM4000. The metal and alloy interfaces are now clearly visible, including enhanced contrast via ion milling after only five minutes. Example Application Data (Cross-section Milling) Composite based materials in electronic components are susceptible to physical stress induced by traditional cross-section techniques. Ion milling with the IM4000 yields a touch less, more precise cross-section solution. : Lead-free Solder : NAND Flash Memory : Copper Interconnect Lead-free solder Ag CuSn alloy layer Cu After Mechanical Polishing After Ion Milling Secondary electron image SEM SU9000 SEM SU9000 The IM4000 in conjunction with sample preparation allows for higher quality results. Channeling contrast, not normally evident after mechanical grinding, is easily observed after ion-milling. : Au Bonding Part The IM4000 processing conditions can be adjusted for low kv ion milling of samples that are susceptible to heat deformation. : Bumper Paint Film Paint film Au Au Ni Substrate After mechanical grinding After ion milling Entire image Expanded image 3 4

Preparation Flow: Removable Stage Unit Pre-processing procedure of a typical sample Flat milling 1 cutting 2 Resin embedding 3 Mechanical polishing 4 Flat milling IM4000 5 Observation and analysis via SEM Easy bench top design for positioning of the sample and mask adjustment Rough polishing Mirror polishing Oblique irradiation of Ar + beam Repeat milling can be performed without stage re-alignment Dedicated optical scope included allows for precise site specific Grinding surface cross-section milling Resin rotation Cross-section milling Multi-layer IC chip package (SD card) 1 cutting 2 Resin embedding or Surface planarization 3 Mechanical polishing Rough grinding 4 Ion milling in IM4000 5 Observation and analysis via SEM Resin Higher Throughput : Improved milling efficiency The all new ion gun reduces mill times and maximizes throughput compared to previous models (Max. milling rate : 300μm/h for Si 66% reduction in : Ceramic capacitor Processing time : 3hours processing time ) Revolutionary Hitachi ion technology incorporated into the IM4000 can now process a ceramic capacitor in only 3 hours. Mask Vertical irradiation of the Ar + beam SEM image of a solder ball interconnect in an electronic device Observation during Ion Milling The IM4000 has an observation port, for in-situ specimen observation. In addition, when using the stereoscopic microscope (option: Binocular type or Tri-eye type) for sample observation during ion milling, the processing surface can be observed up to 100 times magnification. Automated observation is also available by CCD camera (option) mounted on a Tri-eye type optical microscope. CCD camera and monitor are provided by customer. Zoom Stereo Microscope (Tri-eye type) Entire image Expanded image 5 6

System Specifications Source Accelerating voltage range Flat Milling Cross-section Milling Ar (argon) gas 0 to 6kV Maximum milling rate 1 2 Approx. 20μm/h 3 (spot) (Material : Si) Approx. 2μm/h 4 (flat) Approx. 300μm/h 1 2 Maximum sample size 50(dia.) 25(H)mm 20(W) 12(D) 7(H)mm moving range X 0 to +5mm X±7mm Y 0 to +3mm Rotation speed 1r/min, 25r/min Swing angle ±60 ±90 ±15 ±30 ±40 Tilt 0 90 Gas flow rate control system Evacuation system Dimension Weight Optional Accessories Mass flow controller Turbo-molecular pump (33L/s) + Rotary Pump 135L/min at 50Hz,162L/min at 60Hz 616(W) 705(D) 312(H)mm Main unit 48kg Rotary pump 28kg Optical microscope for viewing the specimen during milling Options Zoom stereo microscope unit Binocular type, Tri-eye type (for CCD) 1: This rate is the maximum depth obtained when Si is protruded from a mask edge for processing by 100μm. 2: This rate is the average value obtained when Si is processed for two hours. 3: Illuminating angle : 60 Eccentric value : 4mm 4: Illuminating angle : 0 Eccentric value : 0mm Installation Requirements System layout Room Temperature Humidity Power supply 5 Grounding 15 to 30 C 45 to 85% without moisture condensation AC100V ±10%50/60Hz 1.25kVA 100Ω or less Argon gas cylinder (Provided by customer) Rotary pump Power cord 3 m Ar gas piping 2 m or less Table (700 high) Facilities provided by customer Ar gas Ar gas pressure Ar gas piping 6 Oxygen content meter 7 Recommended table 99.99% purity 0.03 to 0.05MPa 1/8-inch SUS piping (1/8 Swagelok-compatible), Pressure regulator 19% oxygen concentration 1000(W) 800(D) 700(H)mm or more, Min. weight tolerance : 70kg (Minimum strength when installing only IM4000 on the desk) 5: IM4000 is equipped with a power cord with 3-Pin plug. 6: This piping connects Ar gas supply facilities (Ar gas cylinder) and equipment. Prepare together with a pressure governor for supply facilities (Ar gas cylinder). 7: Adequate ventilation and air quality measurements are required. Unit : mm Optical microscope Notice: Follow the instruction manual for proper operation. Specifications in this catalog are subject to change with or without notice, as Hitachi High-Technologies Corporation continues to develop the latest technologies and products for our customers. Copyright (C) Hitachi High-Technologies Corporation 2012 All rights reserved. /global/em/ For technical consultation, please contact:contact@nst.hitachi-hitec.com Printed in Japan (H) HTD-E197P 2012.7