Piezocomposite actuators Piezos for high forces! Faster than resonant frequencies!

Similar documents
Type max. stroke length el. stiffness resonance

4 SENSORS. Example. A force of 1 N is exerted on a PZT5A disc of diameter 10 mm and thickness 1 mm. The resulting mechanical stress is:

Alternative Linear Motion Systems. Iron Core Linear Motors

Programmable Single-/Dual-/Triple- Tone Gong SAE 800

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

Optical Fiber Switches

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

DATA SHEET. TDA8560Q 2 40 W/2 Ω stereo BTL car radio power amplifier with diagnostic facility INTEGRATED CIRCUITS Jan 08

DATA SHEET. TDA1510AQ 24 W BTL or 2 x 12 W stereo car radio power amplifier INTEGRATED CIRCUITS

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

APPLICATION NOTE AP050830

HERZ-Thermal Actuators

Nano Meter Stepping Drive of Surface Acoustic Wave Motor

PRECISION CAPACITOR CHARGING SWITCHING POWER SUPPLIES

Fiber Optic High Density ACC Sensor System Faser Optisches Beschleunigungs-Messsystem

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP

Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015

Understanding Power Impedance Supply for Optimum Decoupling

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Current Probes. User Manual

The Sonometer The Resonant String and Timbre Change after plucking

High-ohmic/high-voltage resistors

TEA1024/ TEA1124. Zero Voltage Switch with Fixed Ramp. Description. Features. Block Diagram

High-ohmic/high-voltage resistors

Rock Bolt Condition Monitoring Using Ultrasonic Guided Waves

Objectives. Electric Current

2000 Series Ultrasonic Welding

Ferroxcube. For more information on Product Status Definitions, see page Sep CBW625

DATA SHEET. TDA1518BQ 24 W BTL or 2 x 12 watt stereo car radio power amplifier INTEGRATED CIRCUITS

Non-Contact Vibration Measurement of Micro-Structures

Torque motors. direct drive technology

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Features. Applications

Acceleration levels of dropped objects

Sound absorption and acoustic surface impedance

Description. Dimensions. Features. precision works better

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Overview of Topics. Stress-Strain Behavior in Concrete. Elastic Behavior. Non-Linear Inelastic Behavior. Stress Distribution.

Encoders for Linear Motors in the Electronics Industry

T = 1 f. Phase. Measure of relative position in time within a single period of a signal For a periodic signal f(t), phase is fractional part t p

Op Amp Circuit Collection

SCS Directory Accreditation number: SCS 0115

DEVELOPMENT AND APPLICATIONS OF TUNED/HYBRID MASS DAMPERS USING MULTI-STAGE RUBBER BEARINGS FOR VIBRATION CONTROL OF STRUCTURES

MODEL 2202IQ (1991-MSRP $549.00)

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Highly flexible couplings

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Analog signal converters CC-E I/I Current / current isolators

Fiber Optics. Integrated Photo Detector Receiver for Plastic Fiber Plastic Connector Housing SFH551/1-1 SFH551/1-1V

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

HIGH VOLTAGE POWER SUPPLY FOR ELECTRO-OPTICS APPLICATIONS

Baseband delay line QUICK REFERENCE DATA

Precision Work on the Human Eye

Safakcan Tuncdemir 1, William M. Bradley *2. 1. Introduction

MEMS mirror for low cost laser scanners. Ulrich Hofmann

Output Ripple and Noise Measurement Methods for Ericsson Power Modules

DATA SHEET. TDA1543 Dual 16-bit DAC (economy version) (I 2 S input format) INTEGRATED CIRCUITS

IEC ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays

Experiment 5. Strain Gage Measurements

LM108 LM208 LM308 Operational Amplifiers

Hi-Rel Latch-Up Current Limiter (LCL) High Input Voltage Range, 2A Output Current Radiation Hardened Design

HIGH POWER FREE SPACE AND FIBER PIGTAILED ISOLATORS

MXD7202G/H/M/N. Low Cost, Low Noise ±2 g Dual Axis Accelerometer with Digital Outputs

RC NETWORKS SALES GUIDE

9000 Series Accelerometers Specifications

1ED Compact A new high performance, cost efficient, high voltage gate driver IC family

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Mounting Instructions. Torque Transducer. A en

LM118/LM218/LM318 Operational Amplifiers

Brush DC Motor Basics. by Simon Pata Business Unit Manager, Brushless DC

Mini-Triggered Spark Gaps & Transformers

LM1036 Dual DC Operated Tone/Volume/Balance Circuit

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

A wave lab inside a coaxial cable

Piezoelectric Driven Non-toxic Injector for Automated Cell Manipulation

Series AMLDL-Z Up to 1000mA LED Driver

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Potentials and Limitations of Ultrasonic Clamp load Testing

Overview of Energy Harvesting Systems (for low-power electronics)

38 Series - Relay interface modules A

Iron Powder Cores for Switchmode Power Supply Inductors. by: Jim Cox

DC Film Capacitors MKT Radial Potted Type

INTERACTION BETWEEN MOVING VEHICLES AND RAILWAY TRACK AT HIGH SPEED

KONSTANTER SPL / SPL Programmable Electronic Load

VIBRATION TEST SYSTEMS. Selection Guide

SOLUTIONS TO CONCEPTS CHAPTER 15

Product Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac

Constructing a precision SWR meter and antenna analyzer. Mike Brink HNF, Design Technologist.

Tamura Closed Loop Hall Effect Current Sensors

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

18 Q0 a speed of 45.0 m/s away from a moving car. If the car is 8 Q0 moving towards the ambulance with a speed of 15.0 m/s, what Q0 frequency does a

TDA W Hi-Fi AUDIO POWER AMPLIFIER

Development of New Inkjet Head Applying MEMS Technology and Thin Film Actuator

10. CNC Hardware Basics

TLI4946. Datasheet TLI4946K, TLI4946-2K, TLI4946-2L. Sense and Control. May 2009

Transcription:

Piezocomposite actuators Piezos for high forces! Faster than resonant frequencies! variable lengths from millimeters to meter high forces up to 70 kn resonant frequencies up to 60 khz

1. Piezocomposite actuators Piezocomposites are linear high load actuators designed in a discrete joining technology. Their advantages lay in high force generation and high stiffness. Another key advantage is the ability to use a variable selection of piezo-ceramics. This variety of thermal behavior, dynamics, voltage stress and Curie temperature allow piezocomposite actuators to be used in countless applications. Applications of piezocomposite actuators Piezocomposite actuators are used for: shaker active vibration damping shock wave generation material testing short impulse excitation features features of piezocomposites (compared to conventional high load actuators) construction of metal-ceramic-compound through discrete joining technology adaptation for special applications through choice of piezoceramic (d 33 ; Curie Temp. loss factor) integrated temperature management for HT applications (thermostable) high shock resistance and high vibrational excitation through optimized construction adjustment of the internal preload 2. Piezoelectrical PIA impulse generators adjustable impact parameters like energy/ acceleration/ deflection/ E < 4 Joule; a > 10.000g, ΔL up to > 100µm high repeatability of the impact parameters, precise time behavior pulse energies in the Joule range variable collision- and repetition rate lowest rising times in the µs s pulse width at about 10 µs precise triggering in the µs-range contact between actuator and specimen before impulse PIA impulse generators provide fast accelerations to test objects, structures and materials. A special dielectrical piezoceramic is used for highly-effective piezo impulse generators with a high power density. The impulse energy density is twice as much as the comparable ceramics for actuators. physical explanation When the piezo actuator is charged quickly (square pulse), then the axial compression stress in the piezo ceramic jumps to a large value. This increase takes place instantaneously, and results in high acceleration with high strain rates. A locking pressure emerges. As a result the piezo-rod expands in an accelerated manner. The piezo stack can build up a propagating pressure front, in a coupled body. Therefore the piezo stack-type actuator is an active rod which generates electrical power pulses when driven by mechanical shocks. Image 1: Scheme of a symmetric acting shock generator working in axial direction

Image 2: Pulse shape of an impulse generator with a symmetrical arrangement Image 3: typical double-pulse shape with the seismic mass PIA-electronics - requirements of the electronic High Voltage Pulser HVP controller high impulse currents up to 400A µs accurate triggering peak power up to 400kW rising times in the µs-range The basic principle of the HVP amplifier is the following: A capacitor (multiple 100µF) is charged with a desired voltage. The capacitor will be disconnected from its power supply and suddenly discharged through the piezoshock generator. Currents reach several hundred Amperes for a short-term period. The voltage which is applied to the piezo thus increases to 1000V within a few µs. Image 4: schematic bipolar control of a power piezo actuator by a high-voltage-pulser (HVP) Examples PIA actuator type operating voltage [V] amplitude at max. current max. acceleration [m/s²] PIA 300/10/3 0 300 7 140 nf > 100 000 PIA 1000/10/7 0 1000 7 20 nf > 100 000 PIA 800/35/80-200 800 80 6,6µF > 100 000

3. Piezoelectrical PiSha Shaker range up to over 100 khz, depending on the configuration of the shaker high accelerations up to 10 000 g amplitudes from microns to several hundred microns (depending on operating ) power modulation of several tens of kn (measured under blocking conditions depending on shaker dimensioning, of operation and installation conditions) compact dimensions of the piezoelectric structures down to the millimeter range high forces thermal management Operating principle of piezoeletric shakers Piezo shaker put the electrical excitation signal directly into a motion. Due to the operating voltage of the shaker, the amplitude of the deflection is determined by the charging current and the speed of the shaker movement (in the sub-resonant mode). The internal structure of the shaker is adapted to the occurring high forces, pressures and accelerations. So the shaker achieves a reliable operation under oscillation at a continuous load. Comparisson piezo-shaker / electromagnetic shaker Compared to their size, piezo shakers have a higher stiffness and force potential at shorter travels than that of electromagnetic shakers. Further applications are miniaturized components, where piezo technology offers higher power densities and smaller sizes. Standard-piezo actuators are normally adapted on smaller dynamics like positioning tasks. To some extent, they can also be used with low modulation for vibrational excitation. However dynamic excitation with high power densities and high frequencies/accelerations require special adaptations in order to achieve reliable operation. Geo-Shaker: for vibration - or pulse excitation of the ground and of buildings coupling to the ground via base plate force-generation: reaction / acceleration forces in conjunction with seismic masses power electronics: amplifier RCV1000/7 (peak power 7 kw) voltages up to 1000 V seismic mass up to 200 kg (depending on the tuning) max. vibration 80 microns max. force modulation ca. +/-15 kn basic response: typically at 200 Hz (depending on the seismic mass) Image 5: Workspaces of piezoelectric and electromagnetic shakers in comparison. Image 6: Geoshaker with seismic mass

Micro-Shaker: Ring type mounting arrangement by clamps or as seismic response type 1 st resonance up to 100 khz max. amplitude: ±5 μm ( dependant) max. force modulation up to 1000 Newton (when fixed with clamps) max. operating voltage: 150 V electrical supply: broadband amplifier LE150/100 EBW Image 7: different micro-shaker. size comparison with thimble Examples PiSha actuator type operating voltage [V] oscillation amplitude* force modulation (blocking limit) [N] 1 st resonant PiSha 300/10/3 0 150 1,5 1800 30 khz PiSha 1000/35/150** 0 1000 75 ±15 000 with seismic mass 200 Hz PiSha 0 150 < 5 1000 100 khz * dependant ** with seismic mass of 80 kg (176 lbs)

4. Product range 4.1. Stack type actuators PSt series - stack type actuators without casing and without preload maximum force generation up to 50 000 N temperature range from -60 C up to over +200 C type * stroke at a voltage of -200 V to 1000 V/ 0 to 1000 V max. stroke* length [mm] electrical [nf] stiffness [N/µm] resonant [Hz] PSt 1000/10/7 12/7 9 20 300 60 PSt 1000/10/20 24/18 18 45 150 40 further versions at www.piezo.eu PSt 1000/35/60 80/60 54 2500 600 20 PSt 1000/35/80 105/80 72 3300 450 15 PSt series - stack type actuators with casing and with preload maximum force generation up to 50 000 N ideally suited for dynamic application due to high preload temperature range from -60 C up to over +200 C type max. stroke* length [mm] electrical [nf] stiffness [N/µm] resonant [Hz] PSt 1000/10/7 VS18 12/7 24 20 300 40 PSt 1000/10/20 VS18 27/20 33 45 150 3 5 further versions at www.piezo.eu PSt 1000/35/150 VS45 200/150 154 570 220 7 PSt 1000/35/200 VS45 260/200 194 6500 150 4 * stroke at a voltage of -200 V to 1000 V/ 0 to 1000 V 4.2. Ring type actuators HPSt series - ring type actuators with casing and without preload inside aperture for optical positioning and laser applications improved cooling also available as 500V version with diameters 10-5 or 15-8 type * stroke at a voltage of -200 V to 1000 V/ 0 to 1000 V max. stroke* length [mm] electrical [nf] stiffness [N/µm] resonant [Hz] HPSt 1000/10-5/7 13/8 9 15 210 50 HPSt 1000/10-5/20 25/17 18 40 110 35 further versions at www.piezo.eu HPSt 1000/35-25/80 105/80 72 1300 250 12 HPSt 1000/35-25/100 130/100 90 1800 160 10

HPSt VS series - ring type actuators with casing and with preload free inside aperture with internal preload: ideally suited for optical applications with high dynamics also available as 500V version with diameters 10-5 or 15-8 type max. stroke* length [mm] electrical [nf] stiffness [N/µm] resonant [Hz] HPSt 1000/10-5/7 VS18 12/7 24 15 210 35 HPSt 1000/10-5/20 VS18 27/20 33 40 110 27 further versions at www.piezo.eu HPSt 1000/35-25/80 VS45 105/80 89 1300 250 12 HPSt 1000/35-25/100 VS45 130/100 107 180 160 10 * stroke at a voltage of -200 V to 1000 V/ 0 to 1000 V 4.3. Piezo-amplifier 1/3-channel-amplifier SVR 1000 - up to 1000V for static and quasi-static applications max. current 8 ma low noise (~ 1mV at 0.47µF load) manual control of DC-offsets The SVR 1000 is available as a multi-channel and single channel amplifier. Due to its low voltage noise, it is excellent for positioning applications, especially for the positioning of optics. switching amplifier RCV 1000/3 - up to 1000 V high load switching amplifier system max. current 3A optionally up to 7A on request manual control of the DC-offset The RCV 1000/3 is a switching amplifier with a peak power of 3 kw. It is ideally suited for dynamic control of high volume piezo-actuators and with capacities in the µf-range.

5. Theory Force In dynamic applications the generation of tensile and pressure forces are bound to the acceleration. For a sinu-soidal input signal the following formula applies: F = force m = moved mass a = acceleration ŝ = amplitude f = working Frequencies With specially designed piezo shakers from piezosystem jena it is possible to work above the resonant. Actuators that work near or above the resonant need to be prestressed. Please consider resonance magnification near the resonance and decrease in amplitude for higher frequencies. Collision excitation For highly effective piezo pulse generators with a high power density a special piezo ceramic material is used. The mechanical impact energy density of the used ceramic material is twice as high as the common ceramic material. The mechanical energy content of the impact depends on the ceramic material (piezoelectric charge constant d 33, young modulus Y), the volume of the actuator (V) and the applied electric field (E). The generated energy can reach several joules. Shock pulse The sock pulse (p) is the product of the mass which is moved into the shock front and the particle velocity. The shock pulse depends on the cross section of the actuator (A) and the used piezo ceramic (mechanical stress σ). p = A T 0 σt dt According to the actuators configuration the shock pulse can reach up to 1 Ns. Particle velocity inside the piezo ceramic The particle velocity matches the maximum displacement velocity of the elementary cell of the piezo ceramic. The particle velocity can reach several m/s. Force generation at the beginning of the pulse The generated force at the beginning of the plunge depends on the actuators cross section, the applied electrical field strength and the type of piezo ceramic. According to the actuators configuration the generated force can reach several 10 s kn. Pulse width The pulse width depends on the runtime of the mechanical pulse in the actuator, the length of the actuator and sonic velocity. According to the actuators configuration the pulse width reaches from a few µs to over 100 µs. Achievable displacement of the plunger The displacement of the plunger depends on the type of piezo ceramic, the length of the piezo stack and the electric field strength. According to the actuators configuration a displacement over 100 µm is possible. For more information please visit: www.piezo.eu piezosystem jena GmbH Stockholmer Straße 12 07747 Jena GERMANY phone: (+49) 3641 66880 fax: (+49) 3641 668866 e-mail: info@piezojena. com piezosystem jena, Inc. 2B Rosenfeld Drive Hopedale, MA, 01747 USA phone: (+1) 508 634 6688 fax: (+1) 508 634 6868 e-mail: usa@piezojena.com