SCS Directory Accreditation number: SCS 0115

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "SCS Directory Accreditation number: SCS 0115"

Transcription

1 International standard: ISO/IEC 17025:2005 Swiss standard: SN EN ISO/IEC 17025:2005 METRON SA Calibration Laboratory Via Luserte Sud 7 CH-6572 Quartino Head: Angelo Capone Responsible for MS: Angelo Capone Telephone: Internet: Initial accreditation: Current accreditation: to Scope of accreditation see: (Accredited bodies) Scope of accreditation as of Calibration laboratory for length, torque and electrical quantities Calibration and Capability (CMC) Best Length Calipers Up to Scale interval DIN mm 0,1 mm 58 µm L Analog indication 0,02 mm 12 µm L 0,01 mm 8 µm L 0,05 mm 29 µm L Digital indication 0,01 mm 13 µm L Dial gauges Scale interval DIN 878, UNI / mm 0,001 mm 0,6 µm Analog indication 0-20 mm 0,002 mm 1,2 µm / G peo/bgs 0115scsvz_engl 1/11

2 Best mm 0,01 mm 6,5 µm 0-2 mm 0,0001 mm 0,3 µm Digital indication 0-10 mm 0,001 mm 1,2 µm mm 0,01 mm 13,0 µm Dial Gauges (Lever- Type) Scale interval DIN 2270, UNI ,002 mm 1,2 µm Analog indication 0,01 mm 6,5 µm 0,001 mm 1,2 µm Digital indication 0,01 mm 13,0 µm Electronic length indicators Scale interval DIN mm 0,0001 mm 0,6 µm External Micrometers 0-25 mm Scale interval 0,001 mm 0,6 µm + 4, L DIN 863 Analog indication 0,010 mm 6,0 µm 0-25 mm 0,001 mm 1,2 µm + 2, L Digital indication > mm 0,001 mm 0,6 µm + 10, L Analog indication 0,010 mm 6,0 µm > mm 0,001 mm 1,2 µm + 7, L Digital indication > mm 0,001 mm 0,6 µm + 11, L Analog indication 0,010 mm 6,0 µm + 2, L > mm 0,001 mm 1,2 µm + 9, L Digital indication > mm 0,001 mm 0,6 µm + 12, L Analog indication / 0,010 mm 4,0 µm + 4, L / G peo/bgs 0115scsvz_engl 2/11

3 Best > mm 0,001 mm 1,2 µm + 11, L Digital indication + 1, L Internal Micrometers 3-line contact Scale interval DIN 863, UNI mm 0,001 mm 2,8 µm + 2, L Analog indication 0,01 mm 6,5 µm + 2, L mm 0,001 mm 3,0 µm + 2, L Digital indication 0,01 mm 12,0 µm + 2, L Depth Micrometers Scale interval DIN mm 0,001 mm 0,6 µm + 4, L Analog indication 0,010 mm 6,0 µm 0-25 mm 0,001 mm 1,2 µm + 2, L Digital indication > mm 0,001 mm 0,6 µm + 10, L Analog indication 0,010 mm 6,0 µm > mm 0,001 mm 1,2 µm + 7, L Digital indication > mm 0,001 mm 0,6 µm + 11, L Analog indication 0,010 mm 6,0 µm 2, L > mm 0,001 mm 1,2 µm + 9, L Digital indication Height measuring instrument Up to Scale interval DIN m 0,1 µm 0,3 µm + 3, L Calibration with angular Laser interferometer 610 mm 0,1 µm 1,2 µm + 2, L Calibration with step gauge / G peo/bgs 0115scsvz_engl 3/11

4 Best Master piece for probe constant Straightness standards 5-45 mm 0,5 µm + 2, L Calibration with horizontal length measuring machine Up to 1500 mm 0,6 µm + 0, L with angular Laser interferometer Plug gauges mm 0,5 µm + 1, L DIN/ISO 286 UNI Gap gauges mm 0,5 µm + 2, L UNI Ring gauges mm 0,5 µm + 2, L UNI Thread ring gauges mm 2,2 µm + 1, L UNI 6974, UNI Pitch mm Simple pitch diameter Thread plug gauges mm 3,0 µm + 1, L UNI Pitch mm Simple pitch diameter Gauge blocks 0.5 mm to 100 mm Material ISO 3650 Central length Steel 0,07 µm + 0, L Ceramic Tungsten carbide 0,08 µm + 0, L 0,1 µm + 0, L Variation in length V with fo and fu 0,05 µm / G peo/bgs 0115scsvz_engl 4/11

5 Best Machine Tools & EDM Machines Positioning error of linear axes Evaluation according to VDI/DGQ 3441, ISO 230-2/4 Up to 30 m Calibration on-site 0,2 µm L with Laser interferometer Horizontal length measuring machine Up to 1 m Calibration on-site 0,2 µm + 1, L with Laser interferometer + Slip Gauge Block Coordinate measuring machine Up to 1m Calibration on-site Uncertainty of the used standard (step gauge) 0,2 µm + 0, L Calibration in according to ISO or VDI 2617 Laser distance measuring instrument Up to 1,6 m 1 digit Comparison with Laser interferometer Perpendicularity of linear axes Reference length 600 mm Calibration on-site Straightness: 1,7 µm / 600mm Granite square Squareness: 1,2 µm / 400 mm Positional deviation of rotary axes Every 30 0,4 With optical polygon and autocollimator Flatness of surface plate Lmin, Bmin : 0.2 m Basis 50 mm Calibration on-site 0.5 µm + 0, L L: Length of surface plate With electronic level meters, according to DIN 876 and ISO 8512 Granite square Up to 1 m Straightness: 0,25 µm + 0, L With optical square and autocollimator Squareness: / G peo/bgs 0115scsvz_engl 5/11

6 Best Direct voltage Voltmeters 0... <330 mv µv 0,33 V... <3,3 V µv 3,3 V... <33 V µv 33 V... <330 V mv 330 V V mv Calibration of 32 V <320 V mv voltage probes 320 V 1050 V mv Calibrators 1 mv <100 mv ,58 mv 0,1 V <1 V ,6 mv 1 V <10 V ,2 mv 10 V <100 V ,8 mv 100 V 1000 V ,0 mv Direct current Current meters 0... <330 μa na <3.3 ma na <33 ma µa <330 ma µa 0,33... <1.1 A µa <3 A µa 3... <11 A µa A 1, µa Calibrators 1 ma <100 ma 1, ,8 ma 100 ma <1 A 1, ,2 ma 1 A 3 A 1, ,6 ma / G peo/bgs 0115scsvz_engl 6/11

7 Best Clamp Meters 1 ma <33 ma µa 33 ma <330 ma µa 0.33 A <1.1 A ma 1.1 A <3 A ma 3 A <11 A ma 11 A <20.5 A ma 20.5 A <110 A ma 110 A <205 A ma 205 A <550 A ma 550 A 1025 A ma Alternate voltage Voltmeters 1 mv <32 mv 10 Hz 45 Hz µv >45 Hz 10 khz µv >10 khz 20 khz µv >20 khz 50 khz µv >50 khz 100 khz µv >100kHz 500kHz µv 33 mv <330 mv 10 Hz 45 Hz µv >45 Hz 10 khz µv >10 khz 20 khz µv >20 khz 50 khz µv >50 khz 100 khz µv >100kHz 500kHz µv 0.33 mv <3.3 V 10 Hz 45 Hz µv >45 Hz 10 khz µv >10 khz 20 khz µv >20 khz 50 khz µv >50 khz 100 khz µv >100kHz 500kHz µv 3.3 V <33 V 10 Hz 45 Hz µv / G peo/bgs 0115scsvz_engl 7/11

8 Best >45 Hz 10 khz µv >10 khz 20 khz µv >20 khz 50 khz µv >50 khz 100 khz mv 33 V <330 V 45 Hz 1 khz mv >1 khz 10 khz mv >10 khz 20 khz mv >20 khz 50 khz mv >50 khz 100 khz mv 330 V 1020 V 45 Hz 1 khz mv >1 khz 5 khz mv >5 khz 10 khz mv Calibration of 32 V <320 V Max 60 Hz mv voltage probes 320 V 1050 V Max 60 Hz mv Alternate current Current meters 29 μa <330 μa 10 Hz 20 Hz 2, µa >20 Hz 45 Hz 1, µa >45 Hz 1 khz 1, µa >1 khz 5 khz 3, µa >5 khz 10 khz 9, µa >10 khz 30 khz 18, µa 0.33 ma <3.3mA 10 Hz 20 Hz 2, µa >20 Hz 45 Hz 1, µa >45 Hz 1 khz 1, µa >1 khz 5 khz 2, µa >5 khz 10 khz 5, µa >10 khz 30 khz 11, µa 3.3 ma <33 ma 10 Hz 20 Hz 2, µa / G peo/bgs 0115scsvz_engl 8/11

9 Best >20 Hz 45 Hz 1, µa >45 Hz 1 khz µa >1 khz 5 khz µa >5 khz 10 khz 2, µa >10 khz 30 khz 4, µa 33 ma <330 ma 10 Hz 20 Hz 2, µa >20 Hz 45 Hz 1, µa >45 Hz 1 khz µa >1 khz 5 khz 1, µa >5 khz 10 khz 2, µa >10 khz 30 khz 4, µa 0.33 A <1.1 A 10 Hz 45 Hz 2, µa >45 Hz 1 khz µa >1 khz 5 khz 7, ma >5 khz 10 khz 28, ma 1.1 A <3 A 10 Hz 45 Hz 2, µa >45 Hz 1 khz µa >1 khz 5 khz 7, ma >5 khz 10 khz 28, ma 3 A <11 A 45 Hz 100 Hz ma >100 Hz 1 khz 1, ma >1 khz 5 khz 34, ma 11 A 20.5 A 45 Hz 100 Hz 1, ma >100 Hz 1 khz 1, ma >1 khz 5 khz 34, ma Clamp meters 1 ma <3.3 ma 45 Hz 1 khz µa 3.3 ma <33 ma 45 Hz 1 khz µa 33 ma <330 ma 45 Hz 1 khz µa 0.33 A <1.1 A 45 Hz 1 khz ma 1.1 A <3 A 45 Hz 1 khz ma / G peo/bgs 0115scsvz_engl 9/11

10 Best 3 A <11 A 45 Hz 1 khz ma 11 A <20.5 A 45 Hz 1 khz ma 20.5 A <110 A 60 Hz 400 Hz ma 110 A <205 A 60 Hz 400 Hz ma 205 A <550 A 60 Hz 400 Hz ma 550 A 1025 A 60 Hz 400 Hz ma Resistance Ohm-meters 0 < m 11 < m 33 < m 110 < m 330 <1.1 k m 1.1 k <3.3 k m 3.3 k <11 k m 11 k <33 k k <110 k k <330 k k <1.1 M M <3.3 M M <11 M M <33 M k 33 M <110 M k 110M <330M k 330 M 1.1 G k Resistance box 10 < ,7 0,1 k <1 k ,8 1 k <10 k ,2 10 k <100 k k <1 M / G peo/bgs 0115scsvz_engl 10/11

11 Best 1 M <10 M ,2 k 10 M 100 M 1, k Calibration of oscilloscopes Square wave signal amplitude 1 mv 6.6 V µv 50 Ohm 1 mv 130 V µv 1 MOhm Time marker 500 ps <2 ns 2 ns <5 ns 5 ns <20 ns 20 ns <100 ns 100 ns <50 ms 50 ms <5 s µs µs ns ns ns ns Risetime 750 ps 1000 ns 29,8 ps - 28,3 ns Torque Torque wrench and screwdriver Nm 1 Nm 1 Nm 3000 Nm With torque transducers 1 % 1 % (1) The given extended measurement uncertainty is the standard uncertainty of the measurement multiplied by an extension factor k = 2, * / * / * / * / * / G peo/bgs 0115scsvz_engl 11/11

Length, Finland, MIKES (VTT Technical Research Centre of Finland Ltd, Centre for Metrology / Mittatekniikan keskus)

Length, Finland, MIKES (VTT Technical Research Centre of Finland Ltd, Centre for Metrology / Mittatekniikan keskus) absolute mise en pratigue: mise en pratigue: absolute absolute Level or Range 633 633 nm 0.04 fm 2 95% No 1 474 474 THz 24 khz 2 95% No 1 532 532 nm 0.08 fm 2 95% No 50 563 563 THz 0.08 MHz 2 95% No 51

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Unit 7 Contact: Mr S C Sparks Solent Industrial Estate Tel: +44 (0)1489 790296 Hedge End Fax: +44 (0)1489 790294 Southampton E-Mail: info@southcal.co.uk

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK code Location code Customers Sites locations: 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK Calibration Centre Bolkiah Garrison BB3510 Negara Brunei Darussalam Contact: Mr Lim Tiong Thai Tel: +673-2-386475

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z & ANSI/NCSL Z SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 & ANSI/NCSL Z540.3-2006 WESCAN CALIBRATION #9-12240 Horseshoe Way Richmond, B.C., V7A 4X9, Canada Malcolm Smith Phone: 604 275 0600

More information

ipimms is an industry primary impedance measurement service supplied and maintained by UK s National Physical Laboratory. [4]

ipimms is an industry primary impedance measurement service supplied and maintained by UK s National Physical Laboratory. [4] Page: 1 of 25 LABORATORY LOCATION: (PERMANENT LABORATORY) AGILENT TECHNOLOGIES MICROWAVE PRODUCTS (M) SDN. BHD. BAYAN LEPAS FREE INDUSTRIAL ZONE 11900 PENANG, MALAYSIA This laboratory accredited under

More information

MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA

MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA This is to signify that MUHAMMAD ABDULLAH AL-AZZAZ COMPANY LIMITED P.O. BOX 31172 AL-KHOBAR 31952 KINGDOM OF SAUDI ARABIA Calibration Laboratory CL-151 has met the requirements of the IAS Accreditation

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 F. D. HURKA COMPANY 4731 Stockholm Court Charlotte, NC 28273 Paul Yanney Phone: 704 552 0008 CALIBRATION Valid To: December 31, 2016

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK Bankhead Industrial Estate Contact: Miss Alexis Ross Bankhead Avenue Tel: +44 (0)1224 710033 Bucksburn Fax: +44 (0)1224 710099 Aberdeen E-Mail: alexis.ross@tdcaberdeen.co.uk

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994. ALLTITE, INC. 1600 Murdock, Wichita, KS 67214 Bruce Demaree Phone: 800 498 6721

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994. ALLTITE, INC. 1600 Murdock, Wichita, KS 67214 Bruce Demaree Phone: 800 498 6721 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z540-1-1994 ALLTITE, INC. 1600 Murdock, Wichita, KS 67214 Bruce Demaree Phone: 800 498 6721 CALIBRATION Valid To: September 30, 2016 Certificate

More information

Eco Green Labs India Pvt. Ltd., Ground Floor, Plot No. 100, New Sidco Industrial Estate, Srinagar, Hosur, Tamil Nadu

Eco Green Labs India Pvt. Ltd., Ground Floor, Plot No. 100, New Sidco Industrial Estate, Srinagar, Hosur, Tamil Nadu Last Amended on - Page 1 of 5 I. DIMENSION $ 1. PLAIN PLUG S Upto Ø 100 mm 1.1 m Using ULM > Ø100 mm to Ø 300 mm 2.4 m 2. PLAIN RING S Upto Ø 100 mm 1.7 m Using ULM >Ø100 mm to Ø 300 mm 3.6 m 3. THREAD

More information

DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements

DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements DMS 680 Universal length measuring system gauge inspection for»iso 9000«requirements Universal length measuring system DMS 680 Wide range of applications For periodic inspection of gauges, reference gauges,

More information

PROMPT ENGINEERING & TRADING SERVICES CO. W.L.L P.O. BOX 24067 BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR

PROMPT ENGINEERING & TRADING SERVICES CO. W.L.L P.O. BOX 24067 BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR This is to signify that PROMPT ENGINEERING & TRADING SERVICES CO. W.L.L P.O. BOX 24067 BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR Calibration Laboratory CL-165 has met the requirements

More information

Scope of accreditation SP Technical Research Institute, Department of Calibration and Verification, Borås - 1002

Scope of accreditation SP Technical Research Institute, Department of Calibration and Verification, Borås - 1002 2015-12-11 2014/2779 Technical Research Institute, Department of Calibration and Verification, Borås - 1002 Accredited calibration activities are conducted at the following laboratories: Box 56 SE-230

More information

COMPUTATIONAL ACCURACY ANALYSIS OF A COORDINATE MEASURING MACHINE UNDER STATIC LOAD

COMPUTATIONAL ACCURACY ANALYSIS OF A COORDINATE MEASURING MACHINE UNDER STATIC LOAD COMPUTATIONAL ACCURACY ANALYSIS OF A COORDINATE MEASURING MACHINE UNDER STATIC LOAD Andre R. Sousa 1 ; Daniela A. Bento 2 CEFET/SC Federal Center of Technological Education Santa Catarina Av. Mauro Ramos,

More information

SPECIFIC CRITERIA for CALIBRATION LABORATORIES IN MECHANICAL DISCIPLINE : Dimensional Metrology

SPECIFIC CRITERIA for CALIBRATION LABORATORIES IN MECHANICAL DISCIPLINE : Dimensional Metrology NABL 122-01 NATIONAL ACCREDITATION BOARD FOR TESTING AND CALIBRATION LABORATORIES SPECIFIC CRITERIA for CALIBRATION LABORATORIES IN MECHANICAL DISCIPLINE : Dimensional Metrology MASTER COPY Reviewed by

More information

Torque Transducers MEASURING ELECTRONIC

Torque Transducers MEASURING ELECTRONIC Screwdriving technology Automation Air motors Air tools MEASURING ELECTRONIC Torque Transducers In most situations, the essential element of screwdriving technology is torque. Controlling the torque generated

More information

The quadrature signals and the index pulse are accessed through five 0.025 inch square pins located on 0.1 inch centers.

The quadrature signals and the index pulse are accessed through five 0.025 inch square pins located on 0.1 inch centers. Quick Assembly Two and Three Channel Optical Encoders Technical Data HEDM-550x/560x HEDS-550x/554x HEDS-560x/564x Features Two Channel Quadrature Output with Optional Index Pulse Quick and Easy Assembly

More information

3 DC Circuits, Ohm's Law and Multimeters

3 DC Circuits, Ohm's Law and Multimeters 3 DC Circuits, Ohm's Law and Multimeters Theory: Today's lab will look at some basics of electricity and how these relate to simple circuit diagrams. Three basic terms are important to a study of electricity.

More information

VALLIAMMAI ENGINEERING COLLEGE SRM NAGAR KATTANKULATHUR DEPARTMENT OF MECHANICAL ENGINEERING ME2304 ENGINEERING METROLOGY AND MEASUREMENT

VALLIAMMAI ENGINEERING COLLEGE SRM NAGAR KATTANKULATHUR DEPARTMENT OF MECHANICAL ENGINEERING ME2304 ENGINEERING METROLOGY AND MEASUREMENT VALLIAMMAI ENGINEERING COLLEGE SRM NAGAR KATTANKULATHUR DEPARTMENT OF MECHANICAL ENGINEERING ME2304 ENGINEERING METROLOGY AND MEASUREMENT QUESTION BANK UNIT I CONCEPT OF MEASUREMENT 1. What are the uses

More information

Calibration. How can you get lower costs for the calibration? What is traceability? What is measurement uncertainty? What is calibration?

Calibration. How can you get lower costs for the calibration? What is traceability? What is measurement uncertainty? What is calibration? Calibration Tvinnargatan 25 SE-507 30 Brämhult SWEDEN Phone: +46 33 22 56 30 Fax: +46 33 13 88 71 info@kalibrera.se www.kalibrera.se In May 2011 Elastocon purchased the company Mätcentrum in Eskilstuna,

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSLI Z540-1-1994 TEKTRONIX, INC. 13725 SW Karl Braun Drive Beaverton, OR 97077 Andrew Mumford Phone: 503 627 2476 CALIBRATION Valid to: June 30, 2018

More information

Position Sensors MicroSense, LLC

Position Sensors MicroSense, LLC Understanding Capacitive Position Sensors 2011 MicroSense, LLC Table of Contents 1. Introduction to Capacitive Sensors... 3 1.1 Characteristics of Capacitive Sensors... 3 1.1.1 Non Contact... 3 1.1.2 High

More information

Digital indicators SUMMARY OF ALL TYPES S233. S_Dial ONE S234

Digital indicators SUMMARY OF ALL TYPES S233. S_Dial ONE S234 DIGITAL indicators The electronic indicators are equipped with a linear sensor and an engraved scale glued on the measuring spindle and a sensor which replaces the gears. The analogic display is transformed

More information

Gauges / Pin gauges / Thread and tolerance tables

Gauges / Pin gauges / Thread and tolerance tables Gauges / Pin gauges / Thread and tolerance tables C2.00.EN-dealer.200825 20, Schut Geometrische Meettechniek bv 27 Measuring instruments and systems 20/202-D Limit gauges for internal and external dimensions

More information

3M CORPORATE METROLOGY SERVICES St. Paul, MN

3M CORPORATE METROLOGY SERVICES St. Paul, MN A2LA has accredited THE AMERICAN ASSOCIATION FOR LABORATORY ACCREDITATION ACCREDITED LABORATORY 3M CORPORATE METROLOGY SERVICES St. Paul, MN for technical competence in the field of Calibration This laboratory

More information

Linear encoders without bearings incremental System for linear motion feedback

Linear encoders without bearings incremental System for linear motion feedback Features Robust magnetic sensing method Output signals A 90 B with index signal Output circuits: HTL/push-pull and TTL/RS422 Resolution up to 5 µm (4-times evaluation) Non-contact, wear-free sensing system

More information

Incremental Linear Encoders

Incremental Linear Encoders Reliable. Sophisticated. Flexible. Incremental Linear Encoders Enclosed Models Design and operation RSF manufactures Linear Encoders in enclosed and open versions. The enclosed models are easy to install

More information

Specific Requirements for Civil Engineering Testing Laboratories

Specific Requirements for Civil Engineering Testing Laboratories ACCREDITATION SCHEME FOR LABORATORIES Specific Requirements for Civil Engineering Testing Laboratories Technical Notes CE 001, Mar 08 The SAC Accreditation Programme is managed by SPRING Singapore All

More information

Gaging & Inspection Tool Design

Gaging & Inspection Tool Design Training Objective After watching the program and reviewing this printed material, the viewer will understand the basic aspects of gaging and inspection tool device design. The various gaging tools are

More information

[ means: Save time, money and space! MAXXMILL 500. Vertical milling center for 5-side machining

[ means: Save time, money and space! MAXXMILL 500. Vertical milling center for 5-side machining [ E[M]CONOMY] means: Save time, money and space! MAXXMILL 500 Vertical milling center for 5-side machining MAXXMILL 500 MAXXMILL 500 is the ideal vertical milling center for the for the 5-axis operation

More information

MOBILE PRECISION TOOL SERVICE CALIBRATION PROCEDURES MANUAL CALIBRATION PROCEDURE MPTS-1

MOBILE PRECISION TOOL SERVICE CALIBRATION PROCEDURES MANUAL CALIBRATION PROCEDURE MPTS-1 MOBILE PRECISION TOOL SERVICE CALIBRATION PROCEDURES MANUAL CALIBRATION PROCEDURE MPTS-1 TABLE OF CONTENTS 1. Objective 3 2. Reference and military documents.3 3. MPTS Standards used for calibration.3

More information

Meters, Power Supplies and Generators

Meters, Power Supplies and Generators 1. Meters Meters, Power Supplies and Generators Generally analog meters respond to the average of the signal being measured. This is due to the mechanical mass of the pointer and the RC response time of

More information

Calibration of AFM with virtual standards; robust, versatile and accurate. Richard Koops VSL Dutch Metrology Institute Delft

Calibration of AFM with virtual standards; robust, versatile and accurate. Richard Koops VSL Dutch Metrology Institute Delft Calibration of AFM with virtual standards; robust, versatile and accurate Richard Koops VSL Dutch Metrology Institute Delft 19-11-2015 VSL Dutch Metrology Institute VSL is the national metrology institute

More information

Three Channel Optical Incremental Encoder Modules Technical Data

Three Channel Optical Incremental Encoder Modules Technical Data Three Channel Optical Incremental Encoder Modules Technical Data HEDS-9040 HEDS-9140 Features Two Channel Quadrature Output with Index Pulse Resolution Up to 2000 CPR Counts Per Revolution Low Cost Easy

More information

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE References for Nuclear Magnetic Resonance 1. Slichter, Principles of Magnetic Resonance, Harper and Row, 1963. chapter

More information

Certificate of Accreditation

Certificate of Accreditation PERRY JOHNSON LABORATORY ACCREDITATION, INC. 393.00 Certificate of Accreditation Perry Johnson Laboratory Accreditation, Inc., has assessed the Laboratory of: (Hereinafter called the Organization) and

More information

LOCKHEED MARTIN TRAINING LOGISTICS SOLUTIONS 100 Global Innovation Cir. Orlando, FL 32825 Frank Wisdo Phone: 800 275 3488

LOCKHEED MARTIN TRAINING LOGISTICS SOLUTIONS 100 Global Innovation Cir. Orlando, FL 32825 Frank Wisdo Phone: 800 275 3488 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005. &ANSI/NCSL Z540-1.1994 & ANSI/NCSL Z540.3.2006 LOCKHEED MARTIN TRAINING LOGISTICS SOLUTIONS 100 Global Innovation Cir. Orlando, FL 32825 Frank Wisdo Phone:

More information

TECHNICAL DATASHEET Incremental Encoder RI 58-H

TECHNICAL DATASHEET Incremental Encoder RI 58-H Through hollow shaft High accuracy by means of integrated flexible coupling Safe shaft mounting Applications: textile machines, motors, drives, copiers NUMBER OF PULSES 1 / 2 / 3 / 4 / 5 / 10 / 15 / 20

More information

PT 2-PE/S-120AC/FM. Extract from the online catalog. Order No.:

PT 2-PE/S-120AC/FM. Extract from the online catalog. Order No.: Extract from the online catalog PT 2-PE/S-120AC/FM Order No.: 2856812 The figure shows the PT 2-PE/S-230AC/FM version DIN rail module with pluggable surge protection type 3 for terminal equipment, fault

More information

MODEL 27106D GILL PROPELLER ANEMOMETER JANUARY 2003 MANUAL PN 27106D-90 R. M. YOUNG COMPANY

MODEL 27106D GILL PROPELLER ANEMOMETER JANUARY 2003 MANUAL PN 27106D-90 R. M. YOUNG COMPANY MODEL 27106D GILL PROPELLER ANEMOMETER JANUARY 2003 MANUAL PN 27106D-90 R. M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 MODEL 27106D

More information

Height Master SERIES 515

Height Master SERIES 515 Technical Data Graduation: 0.001mm Counter resolution:.001 or 0.01mm Micrometer Head Travel stroke: 1 or 20mm itch:.025 /rev or 0.5mm/rev Hysteresis:.00004 or 1µm Standard Accessories Reference Block:

More information

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output

More information

Experiment No. 3 MEASUREMENT OF TAPER ANGLE USING SINE BAR

Experiment No. 3 MEASUREMENT OF TAPER ANGLE USING SINE BAR Experiment No. 3 MEASUREMENT OF TAPER ANGLE USING SINE BAR Aim:- To determine unknown angle using sine bar. Apparatus:- Sine bar, surface plate, dial indicator, slip gauges. Introduction:- Sine bar is

More information

Series 7500 Torque Sensor

Series 7500 Torque Sensor Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement

More information

LARGE MEASUREMENT RANGE MECHANICAL COMPARATOR FOR CALIBRATION OF LONG GAUGE BLOCKS

LARGE MEASUREMENT RANGE MECHANICAL COMPARATOR FOR CALIBRATION OF LONG GAUGE BLOCKS XVII IMEKO World Congress Metrology in the 3rd Millennium June 22 27, 2003, Dubrovnik, Croatia LARGE MEASUREMENT RANGE MECHANICAL COMPARATOR FOR CALIBRATION OF LONG GAUGE BLOCKS Tanfer Yandayan TUBITAK-Ulusal

More information

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES TSI and TSI logo are registered trademarks of TSI Incorporated. SmartTune is a trademark of TSI Incorporated. THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES IFA 300 Constant Temperature Anemometry

More information

Technical Manual CAPACITIVE LOAD CELL TYPE MCL. Doc. Ref CD1048K

Technical Manual CAPACITIVE LOAD CELL TYPE MCL. Doc. Ref CD1048K RDP Customer Document Technical Manual CAPACITIVE LOAD CELL TYPE MCL Doc. Ref CD1048K BS EN ISO 9001 Certificate No. FM13141 Affirmed by Declaration of Conformity USA & Canada RDP Electrosense Inc. 2216

More information

HP 70950B OPTICAL SPECTRUM ANALYZER

HP 70950B OPTICAL SPECTRUM ANALYZER HP 71450B, 71451B, and 71452B Optical Spectrum Analyzers Technical Specifications Spectral Measurements from 600 to 1700 nm HP 70950B OPTICAL SPECTRUM ANALYZER OPTICAL INPUT The HP 71450B, 71451B, and

More information

Manual. Linear scales FOR DIGITAL READ-OUT UNITS

Manual. Linear scales FOR DIGITAL READ-OUT UNITS Manual Linear scales FOR DIGITAL READ-OUT UNITS CONTENT 1. PRECAUTION 2 2. INSTALLATION STANDARDS & REQUIREMENTS 5 Glass grating linear transducer installation manual 1 1. PRECAUTION 1. The travel length

More information

Bore Gages SERIES 526 for Extra Small Holes

Bore Gages SERIES 526 for Extra Small Holes Bore Gages SERIES 526 for Extra Small Holes These gages are designed to measure the diameters of small holes. The radial displacement of the split-ball anvil is converted to axial displacement of the measuring

More information

Inductors in AC Circuits

Inductors in AC Circuits Inductors in AC Circuits Name Section Resistors, inductors, and capacitors all have the effect of modifying the size of the current in an AC circuit and the time at which the current reaches its maximum

More information

Turbine Flow Sensor Series VTR

Turbine Flow Sensor Series VTR Turbine Flow Sensor Series VTR SIKA Turbine Flow Sensor Series VTR Extra robust, impressively precise SIKA s VTR turbine flow sensor allows you to determine precisely, dependably and easily the flow rates

More information

Reaction Torque Sensor

Reaction Torque Sensor Force 1 1 N m up to 1 000 1 000 N m Type 9329A 9389A These easy to install piezoelectric reaction torque sensors are particularly suitable for measuring rapidly changing torques at non-rotating shafts.

More information

] means: More space, more options, more design. emcoturn e45. CNC turning center for bar stock work of up to Ø 45 (51) mm and chucking work

] means: More space, more options, more design. emcoturn e45. CNC turning center for bar stock work of up to Ø 45 (51) mm and chucking work [ E[M]CONOMy ] means: NEW More space, more options, more design. emcoturn e45 CNC turning center for bar stock work of up to Ø 45 (51) mm and chucking work EMCOTURN E45 [Tool turret] - 12 stations VDI

More information

INTERFERENCE OF SOUND WAVES

INTERFERENCE OF SOUND WAVES 1/2016 Sound 1/8 INTERFERENCE OF SOUND WAVES PURPOSE: To measure the wavelength, frequency, and propagation speed of ultrasonic sound waves and to observe interference phenomena with ultrasonic sound waves.

More information

MODELS: 148 GTL 148 GTL ST 148 NW ST REVISION: DATE: 03/11/03

MODELS: 148 GTL 148 GTL ST 148 NW ST REVISION: DATE: 03/11/03 . ALIGNMENT PROCEDURE MODELS: 148 GTL 148 GTL ST 148 NW ST REVISION: 1.111 DATE: 03/11/03 PREPARED BY: BURKE Total Pages: 8 pages Page:1 print date: 3/27/06 1 TEST CONDITION: 148NWST ALIGNMENT INSTRUCTION

More information

Resistivity of a Superconductor

Resistivity of a Superconductor Resistivity of a Superconductor PURPOSE: To investigate the resistive properties of a superconductor as a function of temperature. To gain experience doing measurements at cryogenic temperatures using

More information

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection w Technical Product Information Precision Miniature Load Cell with Overload Protection 1. Introduction The load cells in the model 8431 and 8432 series are primarily designed for the measurement of force

More information

Technical data machine connector M12 1, 4-pole according to IEC ; FIXCON-capable

Technical data machine connector M12 1, 4-pole according to IEC ; FIXCON-capable Data Sheet 902815 Page 1/7 JUMO Dtrans T100 Screw-in RTD temperature probe with/without transmitter for temperatures from -50 to +260 C EHEDG certification complies with ROHS for EU and China configuration

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Old Bracknell Lane West Bracknell Berkshire RG12 7AH Contact: Mr M Trotter Tel: +44 (0)1344 459314 Fax: +44 (0)1344 465556 E-Mail: mtrotter@bis.fm

More information

Measurement & Gaging. Training Objective

Measurement & Gaging. Training Objective Training Objective After watching the program and reviewing this printed material, the viewer will learn the basics of measurement and the use of measuring and gaging tools. The concepts of measurements

More information

GOTT CALIBRATION SERVICES, INC. 185 EAST PAULARINO AVENUE, C103 COSTA MESA, CALIFORNIA 92626

GOTT CALIBRATION SERVICES, INC. 185 EAST PAULARINO AVENUE, C103 COSTA MESA, CALIFORNIA 92626 This is to attest that GOTT CALIBRATION SERVICES, INC. 185 EAST PAULARINO AVENUE, C103 COSTA MESA, CALIFORNIA 92626 Calibration Laboratory has met the requirements of the IAS Accreditation Criteria for

More information

user manual Manual Part No

user manual Manual Part No user manual Manual Part No. 502408 Index 1.0 Introduction..........................2 This Manual...........................2 2.0 Safety Summary......................3 Terms in this Manual....................3

More information

For more information please contact your local UL field representative

For more information please contact your local UL field representative MARK INTEGRITY PROGRAM UL Calibration Requirements: Equipment Used for UL/C-UL/ULC Mark Follow-Up Services UL defines minimum requirements for calibration of inspection, measuring and test equipment (IMTE)

More information

AEDA-3300 Series Ultra Miniature, High Resolution Incremental Kit Encoders. Features. Applications

AEDA-3300 Series Ultra Miniature, High Resolution Incremental Kit Encoders. Features. Applications AEDA-3300 Series Ultra Miniature, High Resolution Incremental Kit Encoders Data Sheet Description The AEDA-3300 series are high performance, cost effective, three-channel optical incremental encoder modules

More information

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications Fiber Optic Sensors - S7 Advanced fiber optic amplifiers for high speed and low contrast applications DIN rail mountable models with dual digital displays speed models: 2 μs...5 ms Super high speed models:

More information

Incremental Linear Encoders

Incremental Linear Encoders Technik, die zählt Technology that counts Incremental Linear Encoders Enclosed Models 1 Table of contents Page General description Design and operation... 4/5 Output signals... 6 Subdividing Electronics,

More information

INyMET SALVATIERRA NO. 32-5 COL SAN BARTOLO ATEPEHUACAN D.F. 07730 MEXICO

INyMET SALVATIERRA NO. 32-5 COL SAN BARTOLO ATEPEHUACAN D.F. 07730 MEXICO This is to signify that INyMET SALVATIERRA NO. 32-5 COL SAN BARTOLO ATEPEHUACAN D.F. 07730 MEXICO Calibration Laboratory CL-101 has met the requirements of the IAS Accreditation Criteria for Calibration

More information

TXR/TXA TRENDSETTER Datasheet

TXR/TXA TRENDSETTER Datasheet TXR/TXA TRENDSETTER Datasheet SPECIFICATIONS Unless otherwise noted, all specifications are specified at 21 C (70 F), +24 Vdc power supply, gap set to 1.27 mm (50 mils) and using Metrix AISI 4140 steel

More information

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig Through hollow shaft Ø 5 bis 4 mm Outside diameter only 76 mm Easy installation by means of clamping ring front or rear Operating temperature up to 00 C Applications: motors, printing machines, lifts NUMBER

More information

Electrical calibration

Electrical calibration Electrical calibration Electrical calibration refers to the process of verifying the performance of, or adjusting, any instrument that measures, sources, or tests electrical parameters. This discipline

More information

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow) Drawing 8c Drawing 9c U391_TA10C_DoP_e_150421 www.hoentzsch.com 1 of 5 Measured

More information

Optics. Determining the velocity of light by means of the rotating-mirror method according to Foucault and Michelson. LD Physics Leaflets P5.6.1.

Optics. Determining the velocity of light by means of the rotating-mirror method according to Foucault and Michelson. LD Physics Leaflets P5.6.1. Optics Velocity of light Measurement according to Foucault/Michelson LD Physics Leaflets P5.6.1.1 Determining the velocity of light by means of the rotating-mirror method according to Foucault and Michelson

More information

R.C.C.B. s two-pole LEXIC

R.C.C.B. s two-pole LEXIC 87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...

More information

Screw-in RTD temperature probe with plug connector according to DIN EN 175301

Screw-in RTD temperature probe with plug connector according to DIN EN 175301 ata sheet 902044 Page 1/8 Screw-in RT temperature probe with plug connector according to IN EN 175301 For temperatures between -50 and +260 C Vibration-resistant design Plug connector locked against contact,

More information

Capacitive sensors for displacement, distance and position

Capacitive sensors for displacement, distance and position Capacitive sensors for displacement, distance and position Capacitive measurement system and sensors with micrometer resolution for linear measurement of displacement, distance and position ideal for insulators

More information

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx DSF..10.**.HV Ex ATEX Operating Instructions 374E-64368 Valid from lot nr. 0103 General Function Use in potentially explosive environment

More information

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181 Compact, rugged housing Many mounting possibilities Status displayed via LED Immune to electromagnetic interference 1024 pulses per revolution (default) 360, 512, 1000, 1024, 2048, 2500, 3600, 4096, parametr.

More information

Exercise 4 - Broadband transistor amplifier

Exercise 4 - Broadband transistor amplifier ANALOG ELECTRONIC CIRCUITS Laboratory work Exercise 4 - Broadband transistor amplifier Task 1: Design a broadband amplifier using a bipolar NPN transistor in a common emitter orientation. For input signal

More information

CAPACITIVE SENSORS. Series KS. Key-Features:

CAPACITIVE SENSORS. Series KS. Key-Features: CAPACITIVE SENSORS Series KS Key-Features: Content: Introduction Applications...2 Technical Data Sensor Heads...3 Technical Drawing...4 Sensor Cabels...5 1 Channel Electronics...6 Description Electronics

More information

True RMS Bench Multimeters 2831E and 5491B

True RMS Bench Multimeters 2831E and 5491B Data Sheet True RMS Bench Multimeters and True RMS Bench Multimeters with Dual Display The B&K Precision models and are versatile and dependable bench multimeters suitable for applications in education,

More information

Subminiature Load Cell Model 8417

Subminiature Load Cell Model 8417 w Technical Product Information Subminiature Load Cell 1. Introduction... 2 2. Preparing for use... 2 2.1 Unpacking... 2 2.2 Using the instrument for the first time... 2 2.3 Grounding and potential connection...

More information

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM Force measurement Forces VECTORIAL ISSUES In classical mechanics, a force is defined as "an action capable of modifying the quantity of movement of a material point". Therefore, a force has the attributes

More information

Ultrasound. - Dosimetry. Gail ter Haar. Joint Physics Department, Royal Marsden Hospital: Institute of Cancer Research, Sutton, Surrey UK

Ultrasound. - Dosimetry. Gail ter Haar. Joint Physics Department, Royal Marsden Hospital: Institute of Cancer Research, Sutton, Surrey UK Ultrasound - Dosimetry Gail ter Haar Joint Physics Department, Royal Marsden Hospital: Institute of Cancer Research, Sutton, Surrey UK Measurable in water Exposure Reduced by: tissue acoustic properties

More information

Table of Contents. Table of Contents Lab Systems SybaPower - Modular power supply systems 3HU modules Measuring instruments/function generators

Table of Contents. Table of Contents Lab Systems SybaPower - Modular power supply systems 3HU modules Measuring instruments/function generators Table of Contents Table of Contents Lab Systems SybaPower - Modular power supply systems 3HU modules Measuring instruments/function generators 1 2 2 3 3 Lucas Nülle GmbH Page 1/8 www.lucas-nuelle.com Lab

More information

Inspection. 9. Inspection and Gaging Tools. Basic principles of gaging. Gage maker tolerances. Gage tolerances

Inspection. 9. Inspection and Gaging Tools. Basic principles of gaging. Gage maker tolerances. Gage tolerances Inspection Nominal dimension 9. Inspection and Gaging Tools Nageswara Rao Posinasetti Tolerance Use Appearance Cost Datum or Reference 1 2 Basic principles of gaging Measurement Measuring can be defined

More information

DS 400 Flow measurement for compressed air and gases New chart recorder DS 400

DS 400 Flow measurement for compressed air and gases New chart recorder DS 400 DS 400 Flow measurement for compressed air and gases New chart recorder DS 400 3.5 graphic display with touch screen - shows the progression of the measured values in graphic form sensors USB interface

More information

SPECIFIC CRITERIA for CALIBRATION LABORATORIES IN MECHANICAL DISCIPLINE : Verification of Impact Testing Machine

SPECIFIC CRITERIA for CALIBRATION LABORATORIES IN MECHANICAL DISCIPLINE : Verification of Impact Testing Machine NABL 122-14 NATIONAL ACCREDITATION BOARD FOR TESTING AND CALIBRATION LABORATORIES SPECIFIC CRITERIA for CALIBRATION LABORATORIES IN MECHANICAL DISCIPLINE : Verification of Impact Testing Machine Reviewed

More information

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155 Technical information Version: 07.14 General Function The speed sensors family DSD.70 are suitable for generating

More information

TOOL WEAR, TOOL LIFE, HAND TOOLS AND MACHINE TOOLS. 1

TOOL WEAR, TOOL LIFE, HAND TOOLS AND MACHINE TOOLS.   1 TOOL WEAR, TOOL LIFE, HAND TOOLS AND MACHINE TOOLS email: vkjain@iitk.ac.in 1 PROCESS OF CUTTING TOOL FAILURE Cutting Tool Failure Mechanisms: 1. By Plastic deformation 2. By chipping due to mechanical

More information

Description. Dimensions. Features. www.pwb-encoders.com. precision works better

Description. Dimensions. Features. www.pwb-encoders.com. precision works better Description The MEC22 is a high resolution optical hollow shaft encoder that can be fixed quickly and easily on different sizes of motor shafts. The encoder provides two square wave outputs in quadrature

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

Date Supersedes document --

Date Supersedes document -- COMMITTEE DRAFT ISO/CD 13225-1 COMMITTEE DRAFT Date 2005-06-03 Supersedes document -- Reference number ISO/TC 213 N 760 WARNING: This document is not an International Standard. It is distributed for review

More information

High Power Laser Assemblies

High Power Laser Assemblies Fiberguide s High Power Assemblies use our High Power SMA and High Power Industrial FD-80 connectors to provide a fiber optic link between the laser source and the target. These are ideal for laser cutting,

More information

Wahl C50 Calibrator FEATURES

Wahl C50 Calibrator FEATURES NEW! On Site Multifunction Portable Far Superior Accuracy as Compared to Fluke! Simultaneous Measurement and Generation Quick Connect Terminals Anti-Shock Boot Quick Connect Terminals Navigator Power Supply,

More information

OUR PRODUCT RANGE SETTING GAUGES P. 39 INSPECTION OF PLAIN SURFACES GAUGES FOR INSPECTION OF THREADS THE CHECKING OF SPLINES AND GEARS SPECIAL GAUGES

OUR PRODUCT RANGE SETTING GAUGES P. 39 INSPECTION OF PLAIN SURFACES GAUGES FOR INSPECTION OF THREADS THE CHECKING OF SPLINES AND GEARS SPECIAL GAUGES OUR PRODUCT RANGE SETTING GAUGES P. 3 INSPECTION OF PLAIN SURFACES P. 9 GAUGES FOR INSPECTION OF THREADS P. 27 THE CHECKING OF SPLINES AND GEARS P. 39 SPECIAL GAUGES P. 45 SPECIAL EQUIPMENT AND SOLUTIONS

More information

Bonding And Loop Resistance Tester >blrt2-xx-x<

Bonding And Loop Resistance Tester >blrt2-xx-x< Bonding And Loop Resistance Tester >blrt2-xx-x< ELECTRICS / ELECTRONICS TEST-FUCHS part no. 52003 AIRBUS CERTIFIED The equipment is developed as multifunctional bonding tester. It is especially

More information

Multifunction Measuring Instrument DS 300 for Compressed Air and Gases

Multifunction Measuring Instrument DS 300 for Compressed Air and Gases Multifunction Measuring Instrument DS 300 for Compressed Air and Gases Northern sales office Am Oxer 28c D-24955 Harrislee fon: +49 (0) 461 700 20 25 Fax: +49 (0) 461 700 20 26 Email: info@cs-instruments.com

More information

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version instrumentation for fluids Electromagnetic sensor Series FLOMID FX Instructions Manual! Conforms with the Pressure Equipment Directive 97/23/EC. 0830 This equipment is considered as being a pressure accessory

More information

PicoScope 6407 Digitizer

PicoScope 6407 Digitizer YE AR PicoScope 6407 Digitizer HIGH PERFORMANCE USB DIGITIZER Programmable and Powerful 1 GHz bandwidth 1 GS buffer size 5 GS/s real-time sampling Advanced digital triggers Built-in function generator

More information