PERFORMANCE RATING OF POSITIVE DISPLACEMENT CONDENSING UNITS

Similar documents
2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units

Performance Rating of Room Fan- Coils

AHRI Standard 325 (Formerly ARI Standard 325) 1998 Standard for Ground Water-Source Heat Pumps

Energy Recovery Ventilation Equipment

Rating Water-Source Heat Pumps Using ARI Standard 320 and ISO Standard

A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures

ANSI/AHRI Standard 880 (I-P) with Addendum Standard for Performance Rating of Air Terminals

Specifications for Refrigerants

2007 Standard for Performance Rating of Commercial and Industrial Unitary Air- Conditioning and Heat Pump Equipment

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

Low GWP Replacements for R404A in Commercial Refrigeration Applications

Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

Development and testing of a multi-type air conditioner without using AC inverters

KINGDOM OF SAUDI ARABIA SAUDI ARABIAN STANDARDS ORGANIZATION SASO. SAUDI STANDARD DRAFT No. 3457/2005

Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance

TEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System

Characteristics of Evaporators

Refrigeration Basics 101. By: Eric Nelson

HVAC Efficiency Definitions

AHRI Standard 1361 (SI) 2016 Standard for Performance Rating of Computer and Data Processing Room Air Conditioners

Schedule 3(A) Room Air Conditioners

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

Theoretical Study on Separate Sensible and Latent Cooling Air-Conditioning System

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)

Comparing Air Cooler Ratings Part 1: Not All Rating Methods are Created Equal

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

UNDERSTANDING REFRIGERANT TABLES

MAC-120HE-01 Air-Cooled Chiller

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

How To Design A Refrigeration System

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Why and How we Use Capacity Control

ANSI/AHRI Standard 1350 (I-P) 2014 Standard for Mechanical Performance Rating of Central Station Air-handling Unit Casings

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

Chapter 3.4: HVAC & Refrigeration System

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Heat Recovery In Retail Refrigeration

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

UNIT 2 REFRIGERATION CYCLE

PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.

Mohan Chandrasekharan #1

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems

Increasing the evaporation temperature with the help of an internal heat exchanger

2011 Standard for Performance Rating Of Water-Chilling and Heat Pump Water-Heating Packages Using the Vapor Compression Cycle

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1

Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram

RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight Temperature glide o C Boiling point (1 atm)

Measurement And Application of Performance Characteristics Of A Free Piston Stirling Cooler

Testing methods applicable to refrigeration components and systems

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

How does solar air conditioning work?

SECTION HEAT PUMPS

ENERGY STAR Program Requirements for Residential Air Source Heat Pump (ASHPs) and Central Air Conditioner Equipment. Partner Commitments.

THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A

Scroll Compressor Development for Air-Source Heat Pump Water Heater Applications

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Laboratory Test Report for Fujitsu 12RLS and Mitsubishi FE12NA Mini-Split Heat Pumps

Dr. Michael K. West, PE 1 Dr. Richard S. Combes, PE 2 Advantek Consulting / Melbourne, Florida

Todd M. Rossi, Ph.D. President

SASO 2663 :2014 ENERGY LABELLING AND MINIMUM ENERGY PERFORMANCE REQUIREMENTS FOR AIR-CONDITIONERS

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

D A T A S H E E T. TX6 Thermo Expansion Valves. Alco Controls TX6. Features. Introduction. Construction

Creating Efficient HVAC Systems

D A T A S H E E T. TX3 Thermo Expansion Valves. Alco Controls TX3. Features. Introduction. Description of bulb charges


REFRIGERATION (& HEAT PUMPS)

How Ground/Water Source Heat Pumps Work

POSSIBILITY FOR MECHANICAL VAPOR RE-COMPRESSRION FOR STEAM BASED DRYING PROCESSES

Heating, Ventilation & Air Conditioning Equipment

Florida Power & Light Company. Business Heating Ventilation & Air Conditioning ( HVAC ) Program Standards. Effective: November 9, 2015

Optimal operation of simple refrigeration cycles Part I: Degrees of freedom and optimality of sub-cooling

How To Know If A Refrigeration System Is Efficient

Research on the Air Conditioning Water Heater System

How To Calculate The Performance Of A Refrigerator And Heat Pump

Large Energy Savings Per Installation VFDs for Large Chillers

RS-44 (R424A) : Q & A

Solenoid valves Type EVU

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Preventive Maintenance Strategies and Technologies Can Pave the Path for Next Generation Rooftop HVAC systems

Glossary of Heating, Ventilation and Air Conditioning Terms

INSTALLATION INSTRUCTIONS HOT GAS BYPASS SYSTEM DESIGN MANUAL

Residential Air Conditioning. Program Standards

Air Conditioners Technical Data

Rittal White Paper 305: Selecting Air Conditioners for Industrial Enclosures By: Judith Koetzsch Mark Corcoran, Editor

Refrigerated Air Dryers. Catalogue

Purpose of Refrigeration

Modeled and Measured Effects of Compressor Downsizing in an Existing Air Conditioner/Heat Pump in the Cooling Mode

CHILLER PLANT CONTROL MULTIPLE CHILLER CONTROLS

The Second Law of Thermodynamics

Skills Canada National Competition Instructions and Competition Details 38 Refrigeration and Air Conditioning / Post - Secondary May 27-30,

Transcription:

ANSI/AHRI Standard 520 (formerly ARI Standard 520) 2004 Standard for PERFORMANCE RATING OF POSITIVE DISPLACEMENT CONDENSING UNITS

IMPORTANT SAFETY RECOMMENDATIONS AHRI does not set safety standards and does not certify or guarantee the safety of any products, components or systems designed, tested, rated, installed or operated in accordance with this standard/guideline. It is strongly recommended that products be designed, constructed, assembled, installed and operated in accordance with nationally recognized safety standards and code requirements appropriate for products covered by this standard/guideline. AHRI uses its best efforts to develop standards/guidelines employing state-of-the-art and accepted industry practices. AHRI does not certify or guarantee that any tests conducted under its standards/guidelines will be non-hazardous or free from risk. Note: This standard supersedes ARI Standard 520-97. Price $10.00 (M) $20.00 (NM) Printed in U.S.A. Copyright 2004, by Air-Conditioning, Heating and Refrigeration Institute Registered United States Patent and Trademark Office

TABLE OF CONTENTS SECTION PAGE Section 1. Purpose...1 Section 2. Scope...1 Section 3. Definitions...1 Section 4. Test Requirements...2 Section 5. Rating Requirements...2 Section 6. Minimum Data Requirements for Published Ratings...3 Section 7. Operating Requirements...3 Section 8. Marking and Nameplate Data...3 Section 9. Conformance Conditions...3 TABLES Table 1. ARI Standard Rating Conditions for Condensing Units for Refrigeration Applications...4 APPENDICES Appendix A. References Normative...5 Appendix B. References Informative...5 Appendix C. Method to Handle Zeotropic Mixtures Informative...6 FIGURES Figure C1. Cycle Process for Single Component Refrigerants and Azeotropic Mixtures...6 Figure C2. Cycle Process for Zeotropic Refrigerant Mixtures...7 Figure C3. Definitions of Subcooling and Superheating...8

PERFORMANCE RATING OF POSITIVE DISPLACEMENT CONDENSING UNITS Section 1. Purpose 1.1 Purpose. The purpose of this standard is to establish, for positive displacement condensing units: definitions; test requirements; rating requirements; minimum data requirements for Published Ratings; operating requirements; marking and nameplate data and conformance conditions. 1.1.1 Intent. This standard is intended for the guidance of the industry, including manufacturers, designers, installers, contractors and users. 1.1.2 Review and Amendment. This standard is subject to review and amendment as technology advances. Section 2. Scope 2.1 Scope. This standard applies to electric motor driven, single and variable capacity positive displacement condensing units for air-cooled, evaporatively-cooled, and water-cooled refrigeration applications. 2.1.1 Refrigerant. The rating points in this standard are based on commonly used refrigerants. 2.2 Exclusions. 2.2.1 This standard does not apply to condensing units intended for use in: a. Household refrigerators and freezers b. Automotive air-conditioners c. Dehumidifiers Section 3. Definitions All terms in this document follow the standard industry definitions in the current edition of ASHRAE Terminology of Heating, Ventilation, Air Conditioning and Refrigeration unless otherwise defined in this section. 3.1 Coefficient of Performance (COP). A ratio of the Cooling/Heating Capacity in watts [W] to the power input values in watts [W] at any given set of Rating Conditions expressed in watts/watt [W/W]. For heating COP, supplementary resistance heat shall be excluded. 3.1.1 Standard Coefficient of Performance. A ratio of the capacity to power input value obtained at Standard Rating Conditions. 3.2 Energy Efficiency Ratio, (EER). A ratio of the Cooling Capacity in Btu/h to the power input values in watts at any given set of Rating Conditions expressed in Btu/(W h). 3.2.1 Standard Energy Efficiency Ratio. A ratio of the capacity to power input value obtained at Standard Rating Conditions. 3.3 Positive Displacement Condensing Unit. A specific combination of refrigeration system components for a given refrigerant, consisting of one or more electric motor driven positive displacement compressors, condensers, and accessories as provided by the manufacturer. 1

3.4 Published Rating. A statement of the assigned values of those performance characteristics, under stated rating conditions, by which a unit may be chosen to fit its application. These values apply to all units of like nominal size and type (identification) produced by the same manufacturer. The term Published Rating includes the rating of all performance characteristics shown on the unit or published in specifications, advertising or other literature controlled by the manufacturer, at stated Rating Conditions. 3.4.1 Application Rating. A rating based on tests performed at application Rating Conditions, (other than Standard Rating Conditions). 3.4.2 Standard Rating. A rating based on tests performed at Standard Rating Conditions. 3.5 Rating Conditions. Any set of operating conditions under which a single level of performance results and which causes only that level of performance to occur. 3.5.1 Standard Ratings Conditions. Rating conditions used as the basis of comparison for performance characteristics. 3.6 Refrigerating Capacity. The capacity associated with the increase in total enthalpy between the liquid refrigerant entering the expansion valve and superheated return gas multiplied by the mass flow rate of the refrigerant. 3.7 "Shall" or "Should". "Shall or should shall be interpreted as follows: 3.7.1 Shall. Where "shall" or "shall not" is used for a provision specified, that provision is mandatory if compliance with the standard is claimed. Should. "Should," is used to indicate provisions which are not mandatory, but which are desirable as good practice. Section 4. Test Requirements 4.1 Test Requirements. All Published Ratings shall be verified by tests conducted in accordance with ASHRAE Standard 23. Section 5. Rating Requirements 5.1 Standard Ratings. Standard Ratings shall be established at the Standard Rating Conditions in Table 1 and shall include its associated power input and Energy Efficiency Ratio (EER). When tested with a specified motor, the associated compressor speed (external drive compressors only) shall also be included as part of the rating. The power required to operate all included accessories such as condenser fans, water pumps, controls, and similar accessories shall be accounted for in the power input and Energy Efficiency Ratio. When external accessories such as water pumps, remote fans, and similar accessories are required for the operation of the unit but not included with the unit, the manufacturer shall clearly state that the rated power input and Energy Efficiency Ratio do not account for additional power required by these external accessories. If a water-cooled condenser is used, the cooling water flow rate and pressure drop shall be specified as part of the rating. 5.2 Application Ratings. Application Ratings shall consist of a Capacity Rating plus the associated power input and Energy Efficiency Ratio (EER). When tested with a specified motor, the associated compressor speed (external drive compressors only), shall also be included as part of the rating. The power required to operate all included accessories such as condenser fans, water pumps, controls, and similar accessories shall be accounted for in the power input and Energy Efficiency Ratio. When external accessories such as water pumps, remote fans, and similar accessories are required for the operation of the unit but are not included with the unit, the manufacturer shall clearly state that the rated power input and Energy Efficiency Ratio do not account for additional power required by these external accessories. 2

If a water-cooled condenser is used, the cooling water flow rate and pressure drop shall be specified as part of the rating. All of the above data shall be reported at stated conditions other than those presented in Table 1. Application Ratings shall be reported at rated voltage, phase, and frequency. 5.3 Tolerances. To comply with this standard, measured test results shall not be less than 95% of Published Ratings for capacity and energy efficiency and power input shall be no more than 105% of the rated values. Section 6. Minimum Data Requirements for Published Ratings 6.1 Minimum Data Requirements for Published Ratings. As a minimum, Published Ratings shall include all Standard Ratings. All claims to ratings within the scope of this standard shall include the statement Rated in accordance with ARI Standard 520. All claims to ratings outside the scope of this standard shall include the statement Outside the scope of ARI Standard 520. Wherever Application Ratings are published or printed, they shall include a statement of the conditions at which the ratings apply. Section 7. Operating Requirements 7.1 Maximum Loading Conditions. The maximum suction dew point temperature limit shall be published. This limit shall be established with the condensing unit operating at conditions as described below: a. Ambient temperature surrounding the condensing unit of 115 F [46.1 C] dry-bulb for all types, 115 F [46.1 C] dry-bulb air temperature entering condenser on air-cooled condensing units, and 80 F [27 C] wet-bulb for evaporatively-cooled condensing units. b. Water inlet temperature of 90 F [32 C] and water outlet temperature of 105 F [40.6 C] for water-cooled condensing units. Make-up water temperature of 90 F [32 C] for evaporatively-cooled units. 7.2 Loading Requirements. The condensing unit shall be capable of operating continuously at the stated maximum loading conditions of 7.1 for a minimum period of two hours at minimum and maximum utilization voltages as described in ARI Standard 110, Table 1. Section 8. Marking and Nameplate Data 8.1 Condensing Unit Nameplate Marking. As a minimum, each condensing unit shall have a nameplate, affixed to its housing or base, on which at least the following information shall be marked: a. Manufacturer's name and/or symbol b. Model number c. Refrigerant designation per ASHRAE 34 d. Input voltage and frequency (Hz) e. Rated load current (where applicable) Nameplate voltages for 60 Hertz systems shall include one or more of the equipment nameplate voltage ratings shown in Table 1 of ARI Standard 110. Nameplate voltages for 50 Hertz systems shall include one or more of the utilization voltages shown in Table 1 of IEC Standard 60038. Section 9. Conformance Conditions 9.1 Conformance. While conformance with this standard is voluntary, conformance shall not be claimed or implied for products or equipment within the standard s Purpose (Section 1) and Scope (Section 2) unless such product claims meet all of the requirements of the standard and all of the testing and rating requirements are measured and reported in complete compliance with the standard. Any product that has not met all the requirements of the standard shall not reference, state, or acknowledge the standard in any written, oral, or electronic communication. 3

Table 1. AHRI Standard Rating Conditions for Condensing Units for Refrigeration Applications* Type of Condensing Unit Suction Dew Point Temperature Compressor Type Return Gas Temperature Air-Cooled Water-Cooled Evaporatively - Cooled Air Entering Dry-Bulb (indoor/outdoor) In Out Air Entering Wet-Bulb Temperature Variable Capacity Setting*** F C F C F C F C F C F C 45 7.2 All 65 18 90/95 32/35 85 29 95 35 75 24 MAX/MIN 20-6.7 All** 40/ 65** 4.4/ 18** 90/95 32/35 85 29 95 35 75 24 MAX/MIN -10-23 Hermetic 40 4.4 90/95 32/35 85 29 95 35 75 24 MAX/MIN -25-32 All** 40/ 65** -40-40 All** 40/ 65** 4.4/ 18** 4.4/ 18** 90/95 32/35 85 29 95 35 75 24 MAX/MIN 90/95 32/35 85 29 95 35 75 24 MAX/MIN * Sub-cooling in F [ C], shall be stated as obtained under pertinent application conditions, as measured at the liquid line leaving the condensing unit. ** 1) For hermetic type compressors, 40 F [4.4 C] return gas temperature shall be used. 2) For external drive and accessible hermetic type compressors, 65 F [18 C] return gas temperature shall be used. *** The maximum and minimum capacity setting is the highest and lowest displacement capacity by the condensing unit. 4

APPENDIX A. REFERENCES NORMATIVE A1 Listed here are all standards, handbooks and other publications essential to the formation and implementation of the standards. All references in this appendix are considered as part of the standard. A1.1 ANSI/ASHRAE Standard 34-2001 with Addenda, Number Designation and Safety Classification of Refrigerants, 2001, American National Standards Institute/American Society of Heating, Refrigerating and Air- Conditioning Engineers, 11 West 42 nd Street, New York, NY 10036, U.S.A./1791 Tullie Circle N.E., Atlanta, GA 30329, U.S.A. A1.2 AHRI Standard 110-2002 (formerly ARI Standard 110-2002), Air-Conditioning and Refrigerating Equipment Nameplate Voltages, 2002, Air-Conditioning, Heating, and Refrigeration Institute, 2111 Wilson Boulevard, Suite 500, Arlington, VA 22201, U.S.A. A.1.3 ASHRAE Standard 23-1993, Methods of Testing for Rating Positive Displacement Refrigerant Compressors and Condensing Units, 1993, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., 1791 Tullie Circle, N.E., Atlanta, GA 30329-5478, U.S.A. A1.4 ASHRAE Terminology of Heating, Ventilation, Air Conditioning and Refrigeration, Second Edition, 1991, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., 1791 Tullie Circle, N.E., Atlanta, GA 30329-5478, U.S.A. A1.5 IEC Standard 60038, IEC Standard Voltages, 2002, International Electrotechnical Commission, 3, rue de Varembe, P.O. Box 131, 1211 Geneva 20, Switzerland. A1.6 ISO 917: 1989, Testing of Refrigerant Compressors, 1989, International Organization for Standardization, Case Postale 56, CH-1211, Geneva 21 Switzerland. APPENDIX B. REFERENCES INFORMATIVE None. 5

APPENDIX C. METHOD TO HANDLE ZEOTROPIC MIXTURES INFORMATIVE C1 Cycle Process For reference, Figure C1 shows a typical single stage cycle for single component refrigerants and azeotropic mixtures. The description is consistent with the ISO 917 standard. As shown, the evaporating and condensing processes occur at fixed temperatures t o and t c. Figure C1: Cycle Process for Single Component Refrigerants and Azeotropic Mixtures 6

Figure C2: Cycle Process for Zeotropic Refrigerant Mixtures Figure C2 shows temperature glide for zeotropic refrigerant mixtures at the evaporation and condensation processes. Standard reference temperatures are the dew-point temperatures t " 0 at the evaporating pressure p g1 and t " c at the condensing pressure p g2. The following equations may be used to calculate the mean evaporating temperature, mean condensing temperature, refrigerant superheating, and refrigerant subcooling: mean evaporating temperature: t 0,m = (t 01 + t " 0 ) / 2 C1 mean condensing temperature: t c,m = (t ' c + t " c ) / 2 C2 refrigerant superheating: t Sg = t g1 - t " 0 C3 refrigerant subcooling: t Sf = t ' c - t f2 = t f1 - t f2 C4 Because t 01 = t " 0 and t ' c = t " c for single-component refrigerants and azeotropic multi-component refrigerants, the cycle process model represents a particular kind of model for zeotropic refrigerant mixtures. In all reference systems, refrigerating capacity is: Q = m (h g1 h f2 ) C5 7

and Q 0 = m (h g1 h f1 ) C6 for refrigerating capacity converted to no subcooling. The reference systems described above allow one to calculate and present performance data for all kinds of refrigerants in a similar way. ISO 917 requires zero subcooling for the calculation of refrigerating capacity of the compressor. In this case h f1 and h f2 are equal. Note: In connection with zeotropic mixtures, different definitions of the expressions superheating and subcooling can be found in technical documentation (Figure C3). The Equations C3 and C4 are equivalent to A in Figure C3 and shall be used for the purpose of calculating ratings. For reference only, B in Figure C3 with mean temperatures as reference points, uses the following equations: refrigerant superheating: t Sg = t g1 - t 0,m C7 refrigerant subcooling: t Sf = t c,m - t f2 t f1 - t f2 C8 Figure C3: Definitions of Subcooling and Superheating 8

C2 Symbols and Subscripts Symbols: f1 = Bubble point at condensing process. g 1 = Point where the refrigerant enters the compression process. g 2 = Point where the refrigerant leaves the compression process h f1 = Enthalpy of the refrigerant at bubble point of condensing process. h f2 = Enthalpy of the subcooled refrigerant liquid entering the expansion process. h g1 = Enthalpy of the refrigerant gas entering the compression process. m = Refrigerant mass flow rate. p g1 = Compressor suction dew point pressure. p g2 = Compressor discharge dew point pressure. Q = Refrigerating capacity. Q 0 = Refrigerating capacity assuming no subcooling. t c = Condensing temperature. t c ' = Bubble point temperature at condensing process. t c '' = Dew point temperature at condensing process. t c,m = Mean condensing temperature. t f1 = Temperature at which the subcooled liquid exits the expansion process t f2 = Temperature at which the subcooled liquid enters the expansion process. t g1 = Temperature of the refrigerant entering the compression process. t 0 = Evaporating temperature. t 0 '' = Dew point temperature at evaporation process. t 01 = Temperature at the outlet of the expansion process and inlet to the evaporation process. t 0,m = Mean evaporating temperature. t sf = Refrigerant subcooling. t sg = Refrigerant superheat. Subscripts: c = Condensing process Mean condensing process c,m = f1 = Bubble point of condensing process f2 = Point at which the subcooled refrigerant liquid enters the expansion process g1 = Dew point at compressor suction g2 = Dew point at compressor discharge 0 = Evaporating process 01 = Outlet of the expansion process and inlet to the evaporation process 0,m = Mean evaporating process sf = Saturated fluid sg = Saturated gas 9