ChilledDoor. Rack Cooling System. cooling solutions

Similar documents
Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

Element D Services Heating, Ventilating, and Air Conditioning

Blade Server & Data Room Cooling Specialists

In Row Cooling Options for High Density IT Applications

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

APC APPLICATION NOTE #112

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

How To Improve Energy Efficiency Through Raising Inlet Temperatures

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

Energy Efficient Data Centre at Imperial College. M. Okan Kibaroglu IT Production Services Manager Imperial College London.

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

- White Paper - Data Centre Cooling. Best Practice

Data Center Design Guide featuring Water-Side Economizer Solutions. with Dynamic Economizer Cooling

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

University of St Andrews. Energy Efficient Data Centre Cooling

State of the Art Energy Efficient Data Centre Air Conditioning

EHDC. Cooling system for Data Center and server cabinets.

Rittal Liquid Cooling Series

Alcatel-Lucent Modular Cooling Solution

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Unified Physical Infrastructure (UPI) Strategies for Thermal Management

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

Data Center Components Overview

Benefits of. Air Flow Management. Data Center

CRAC Precision climate control units for data centres

Improving Data Center Efficiency with Rack or Row Cooling Devices:

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

The Different Types of Air Conditioning Equipment for IT Environments

High Density Data Centers Fraught with Peril. Richard A. Greco, Principal EYP Mission Critical Facilities, Inc.

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA

GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.

Benefits of Cold Aisle Containment During Cooling Failure

Rotary screw compressors kw 5,5 7, , bar MODULO

Nirvana. Cycling Refrigerated Dryers

How to Build a Data Centre Cooling Budget. Ian Cathcart

STULZ Water-Side Economizer Solutions

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Cooking at the Speed of light!

European Code of Conduct for Data Centre. Presentation of the Awards 2014

Drives and motors. A guide to using variable-speed drives and motors in data centres

Dealing with Thermal Issues in Data Center Universal Aisle Containment

APC APPLICATION NOTE #92

Data Center Energy Profiler Questions Checklist

How To Improve Energy Efficiency In A Data Center

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

National Grid Your Partner in Energy Solutions

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

I-STUTE Project - WP2.3 Data Centre Cooling. Project Review Meeting 8, Loughborough University, 29 th June 2015

Blade Servers and Beyond: Adaptive Cooling for the Next Generation of IT Systems. A White Paper from the Experts in Business-Critical Continuity

Data Center Environments

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Direct Fresh Air Free Cooling of Data Centres

ECOCIAT. Domestic hot water heat recovery unit

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015

Improving Data Center Energy Efficiency Through Environmental Optimization

Thermal Mass Availability for Cooling Data Centers during Power Shutdown

Managing Data Centre Heat Issues

White Paper Rack climate control in data centres

Data Center Power Consumption

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

DOE FEMP First Thursday Seminar. Learner Guide. Core Competency Areas Addressed in the Training. Energy/Sustainability Managers and Facility Managers

Airflow Simulation Solves Data Centre Cooling Problem

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

RPV - RP - RA air handling units

White Paper #10. Energy Efficiency in Computer Data Centers

Rittal White Paper 508: Economized Data Center Cooling Defining Methods & Implementation Practices By: Daniel Kennedy

Medical Air Systems: Scroll

Thermal Storage System Provides Emergency Data Center Cooling

The New Data Center Cooling Paradigm The Tiered Approach

Reducing Data Center Energy Consumption

Nordic Heat Pump Product Guide

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Supporting Cisco Switches In Hot Aisle/Cold Aisle Data Centers

Legacy Data Centres Upgrading the cooling capabilities What are the options?

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Analysis of data centre cooling energy efficiency

Desiccant Air Dryers Heatless, Heated and Heated Blower

Rittal White Paper 507: Understanding Data Center Cooling Energy Usage & Reduction Methods By: Daniel Kennedy

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency

Cooling Small Server Rooms Can Be. - Jim Magallanes Computer Room Uptime: Uptime Racks:

White Paper. Data Center Containment Cooling Strategies. Abstract WHITE PAPER EC9001. Geist Updated August 2010

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Scalable. Affordable. Flexible. Fast.

NAISSUS THERMAL MANAGEMENT SOLUTIONS

Screw Compressors ESM Fixed Speed & VS Variable Speed

Improving Rack Cooling Performance Using Airflow Management Blanking Panels

Contents Error! Bookmark not defined. Error! Bookmark not defined. Error! Bookmark not defined.

Data Center. Ultra-Efficient chilled water system optimization. White paper. File No: Date: december 03, 2015 Supersedes: new Date: new

Transcription:

cooling solutions

Server heat densities are increasing rapidly in government, institutional, financial and co-location applications, while HPC systems are designed to provide increased computational speeds within limited rack space. The Motivair Chilled Door manages the critical cooling requirements of higher density server racks which cannot be effectively cooled with traditional air conditioning, in-row coolers or passive rear door coolers - and at the lowest possible energy cost. The latest Motivair Chilled Door is an active hinged door that replaces the rear door of any standard or OEM server rack via an interface frame. The Chilled Door is capable of removing up to 45 kw per rack with 65F supply water, using less than 500 watts of fan power. Over 50 different variables are constantly monitored and controlled via a custom PLC to ensure that the Chilled Door is actively adjusting to conditions inside the data center and the server rack. By actively removing 100% of the heat load at its source, the Motivair Chilled Door system results in a Heat Neutral white space that requires little or no air conditioning. Hot aisle/cold aisle configurations are eliminated, data center square footage is reduced, raised floors are optional and energy efficiency can be increased by up to 90% compared to legacy cooling systems. The Motivair Chilled Door always operates above the dew point of the data center, which eliminates the possibility of condensation near critical electrical equipment. 100% sensible cooling eliminates wasted energy by CRAC units or in-row coolers via accidental de-humidification and re-humidification. As a result, no condensate pumps or piping are required. The Chilled Door was designed with an aluminum coil frame to reduce weight and eliminate zinc whiskers. 1

ChilledDoor Motivair Chilled Door How It Works The Motivair Chilled Door removes heat generated by the servers and other IT equipment directly at its source thus preventing hot exhaust air from entering the white space; ensuring optimum data center thermal and energy performance. Room temperature air, typically 68 F-80 F, enters the front of the server rack and passes over the servers, picking up heat as it moves towards the back of the rack or IT enclosure. Centrifugal fans with EC motors located inside the Chilled Door then draw the heated air through the Chilled Door heat exchanger where 100% of the server heat load is removed and transferred to the cooling water. The conditioned air is returned to the room at the Exploded View of Chilled Door same temperature it entered the rack, while the heated water flows to the chiller plant, radiator or cooling tower outside, where the heat is rejected. Elevated cooling water temperature (65F) allows any chiller to operate more efficiently, or permits the use of tower water, aquifer water or other low cost cooling sources. The Chilled Door PLC continuously monitors fan speed, server entering air, Chilled Door discharge air, entering and leaving cooling water temperatures. The fan speed and water flow rate are automatically adjusted in real time to provide the lowest operating cost at any heat load or configuration. Motivair Chilled Doors are designed for control of the complete data center environment populated by higher density server racks. They can also be used for retrofit applications where high density server racks are added to an existing data center and cannot be effectively cooled by traditional means. The self-contained Chilled Door design lends itself to simple and effective application in any data center with minimal disruption. 2

Maximum Cooling with Minimum Energy A Chilled Door System eliminates Hot Spots in the data center by removing 100% of the server heat at its source using minimum fan power and will actively respond to changing configurations of individual server racks, assuring ultimate operator flexibility. Cooling capacities up to 45 kw per Chilled Door using 65 F water ensure that high density loads can be actively cooled and controlled without on-site experimentation or continuous alteration of floor vents, aisle containment or CRAC unit re-location. 65 F chilled water guarantees no energy is wasted in accidental latent cooling or re-humidification and eliminates the need for condensate pumps or piping. The Chilled Door design allows 35% reduction in electrical energy for any new or existing chiller when supplying chilled water at 65 F, compared to 44 F traditional chilled water supply temperature. Free Cooling The Motivair Chilled Door system reaches optimal energy efficiency when applied with a Motivair Free Cooling Chiller. Energy savings up to 90% can be achieved compared with legacy data center cooling systems. The Chilled Door System utilizes supply water/glycol at 65 F, returning this fluid to the Free Cooling Chiller at 75 F, When outside temperatures fall below 75 F the integrated Free Cooling system automatically pre-cools the return fluid and the compressors unload. At 45 F ambient the Free Cooling Chiller requires only the condenser fans to provide full cooling capacity and the compressors are switched off. Free cooling chillers permit the indirect use of outside ambient air for free cooling without any possibility of data center contamination. A major, added benefit is the compressors in Motivair Free Cooling Chillers, when used with Chilled Doors, are never required to start, or operate below 45 F ambient, which significantly reduces run time and extends compressor life. Geographical areas that were previously considered too warm for water side economizers can now benefit from the merging of Motivair Chilled Door and Free Cooling technologies. The result is a highly efficient data center capable of reducing overall energy consumption by up to 90% when compared to traditional data center cooling systems. Chilled Door installations can also benefit by using other low-cost cooling water supplies such as rivers, lakes, aquifers and cooling towers. 3 Modular, Scalable, and easy to install A Chilled Door can be easily installed on any standard or OEM computer rack via an optional Interface Frame, allowing a data center operator to retrofit a Motivair Chilled Door to any existing rack(s) and saving the expense of decommissioning older cabinets. The Interface Frame has been designed so no additional weight is transferred to the existing rack system. Zero-clearance hinges and nesting doors permit installation in virtually any location. The Chilled Door system can also be actively applied to systems with problematic hot spots; where the need to reduce the carbon foot print is a driving factor; or in data centers where space has become a premium and higher densities must be created in existing racks. Chilled Doors can be added as an installation grows, without disrupting the DP operation. Minimal installation time is required. With adequate pre-installation planning the installation of a Chilled Door can be completed within a 1/2 hour.

Motivair Chilled Door Packaged System The latest generation Chilled Door has been uniquely designed to address performance & reliability, along with space constraints and security limitations inside the data center. The hinged Chilled Door is now a completely packaged system. In addition to improved efficiency EC fans & cooling coil, this generation includes the PLC, power & control devices all mounted inside the door - truly plug & play, requiring only the customer power & water connections to become fully operational. The front stainless steel hinged door-within-a-door affords instant access to all electrical components & controls with no tools required. Fans are hot-swappable in complete safety while the others remain fully operational with the Chilled Door closed. Safety fuses and terminal connections are all easily accessible through the front access panel. A minimum load safety factor of 375% on the zero clearance hinges and a key lock entry system allow the Chilled Door to be easily opened & closed safely & securely. Optional, quick-connect hydraulic flex-hose assemblies with reinforced structure & custom lengths are individually tested & tagged for 250 psig (17 Bar) operation for a wide safety margin. The minimum bend radius of 1 without distortion provides extreme flexibility for improved installation & operating convenience. Controls & Alarms The Chilled Door is supplied with a powerful PLC control & alarm system to cover virtually every possibility. The PLC is located in the front face of the Chilled Door for immediate access to all controls, alarms and history of events. A 5-line LCD Alfa numeric display indicates normal operating conditions with an override display for alarms. Three levels of access code protect secure operation - operator, service technician & factory only. Parameters monitored & controlled include fan speed, water flow, inlet air, outlet air, inlet water, and outlet water temperatures. Standard alarms and response include fan failed (individually identified) high inlet & outlet air temperature, high inlet & outlet water temperature, Leak Prevention System (LPS) and emergency full speed fan operation on PLC failure. The Motivair Leak Prevention System (LPS) shuts off the water supply to the Chilled Door, increases fan speed to maximum, and sets the alarm. A unique fail-safe sequence shuts off the water supply, even in the unlikely event of simultaneous water detection and power outage. The adjacent Chilled Doors share any surplus heat load providing total operational redundancy. Dual power supply is an available option and remote communication is available via LON, Bacnet or Modbus. Coolant Distribution Unit (CDU) The available Motivair Coolant Distribution Unit (CDU) provides an interface between an unsuitable (too cold &/or or dirty) building cooling water supply, and a separate (clean 65F) closed loop water supply for the Chilled Doors. The CDU Is enclosed in a rack-type enclosure, physically & aesthetically matching the server racks. It includes a stainless steel heat exchanger, automatic standby pumps, control panel and all necessary piping, valves & PLC control & alarm system. The CDU is also provided with supply & return headers, including quick-connect flexhose fittings for each Chilled Door. Standard supply includes a PLC-powered water detection and alarm system with remote communication available via LON BACnet or Modbus. 4

Chilled Door Management System M4 M8 M12 Cooling capacity with 65F cooling water (kw): 25 35 45 Rack size 42U/48U x 600/800 mm* S S S Fan quantity 2 5 5 PLC with local HMI screen S S S Variable fan speed S S S Coolant flow control S S S Dual power supply O O O Network remote status monitoring O O O High/low air & water temperatures S S S Individual fan fail sensing S S S Local status indicator alarm S S S Leak Prevention System S S S Emergency Fan Operation on PLC failure S S S Common Alarm S S S Power Supply 110-240/1/50-60; 5A max current * Other sizes available; S= standard; O= optional ETL tested, approved & labeled to UL & CSA standards Manufactured in the USA 5

cooling solutions 85 Woodridge Drive, Amherst, NY 14228 Tel: 716-691-9222 Fax: 716-691-9229 Rev. 12/2012