Sensa S2 Multi-sensor for DALI system

Similar documents
basicdim DGC Compact control module

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

PHASED OUT. Digital dimmable ballasts for fluorescent lamps EXCEL one4all series. PCA TCL EXCEL one4all, W Compact and T5c fluorescent lamps

Operating instructions IV / 2007

Operating instructions II / 2004

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y, 3x14/24 W and 4x14/24 W EXCEL T5

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

FL ballasts Electronic dimming. PCA T5 ECO lp Y II, W ECO T5

LED Driver Compact dimming. Udriver LCAI 100W 900mA 1750mA ECO SR ECO series

EBDSPIR-DD, EBDSPIR-DD-IP

DALI RC BASIC SO. Control unit Operating instructions

LED Driver Compact dimming. Udriver LCAI 35W 350mA 900mA ECO C ECO series

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCL ECO, W Compact and T5c fluorescent lamps

FL ballasts Electronic dimming. PCA T5 EXCEL one4all lp Y II, W EXCEL T5

Emergency lighting units EM powerled

Operating instructions

connecdim Gateway G1 Ethernet TCP/IP to DALI

Busch-Watchdog Presence EIB Type:

EBDSPIR-PRM, EBDSPIR-PRM-IP

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

KNX Lighting Control System

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Unica for KNX system 226

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

PRESENCE DETECTOR PD-C360i/24 KNX ECO (EP )

Product and functional description

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

ACS-30-EU-EMDR-10-MOD

LED control gear. LED control gear

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE

AlarmSense 2-wire detection and alarm system. Product Guide

DIGITAL CONTROLS OVERVIEW

Installation and User Guide

Technical Manual MDT Rain sensor

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

DALI Driver Configurator User Guide

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Lighting Management solutions

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

LED light engine / OLED LED compact. Uengine STARK DLE PREMIUM system data sheet STARK DLE

Digidim 458/DIM8 8-Channel Dimmer Module. Installation and User Guide

T7560A,B,C Digital Wall Module

PART 1 PRODUCT (GENERAL)...1.

13 SERIES. Electronic step relays A

Digital input modules

ZME_05459 Wall Blind Control Set for Busch-Jaeger DURO 2000 Firmware Version : 1.8

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens CLASSIC umodule QLE

Inwall 4 Input / 4 Output Module

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

FIRERAY 2000 Installation Guide

ABB i-bus KNX DALI-Gateway DG/S 8.1

SMART SENSOR COLLECTION

PRODUCT MANUAL IRSC. IRSC-Plus. Air-Conditioning controller ZN1CL-IRSC. Program version: 5.14 Manual edition: 5.14_a

How To Use A Power Supply On A Powerline 2.2 (Ai)

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

HERZ-Thermal Actuators

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Electronic Control Devices The European Product Catalogue 2007

FIREDEX Conventional Fire Panels

Fire & Security DETECTORS

LINEAR SYSTEM 3000K 4000K 5000K 6000K 7000K

MOTION SENSOR PIR LIGHT SWITCH INSTALLATION & OPERATING. Cat No. ZV810 INSTRUCTIONS

LED light engine / OLED LED linear /area. Umodule STARK LLE CLASSIC STARK LLE. Ordering data

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

COLOR TFT LCD MONITOR. User Manual

New XUY roller sensors

High Bay Occupancy Sensor Selection Guide

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Inwall Room Temperature Unit

INSTRUCTION MANUAL OVERVIEW Remote Meter: MT-5 Remote meter (Model MT-5) is available to connect with solar controller Tracer MPPT series.

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

My home. Mobile phone application. Instructions for use and installation. For DELTA DORE GSM transmitters and transmitter control units.

LRM207x, LRM208x, LRM209x Datasheet OccuSwitch DALI sensor/controller

Heating, air-conditioning, cooling

ABB i-bus EIB Logic Module LM/S 1.1

Product Catalogue August Energy management Switches and controls

IS3016A Passive Infrared Motion Sensor with Anti-Mask - Installation Instructions

WD-AMX Water Detection Controllers

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Triple Waveband Infra-Red Flame Detection

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 6mm R SNC, SLE G4 10mm R SNC umodule SLE ESSENCE

Highly flexible the right KNX/DALI gateway for every requirement

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

Operating instructions. RCD flat 4-fold, 6-fold

Product and Application Description

Transmitter Actuator 230V wave UP 560. Operation

80 Series - Modular timers 16 A. Features

mecotron Safety relay ESTOP-2 For emergency stop monitoring

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

SOLUTIONS FOR THE CONTROL OF THE WHOLE BUILDING

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Application Unit, MDRC AB/S 1.1, GH Q R0111

Transcription:

S2 Multi-sensor for DALI system Component of the system (DALI standalone) With ambient light dependent control and presence detection Simple group assignment via rotary switch Multiple S2 sensors possible in a group Can be remote controlled Lighting control and presence detection can be deactivated Individual adjustment of the parameters with configuration software Multi-master compatible: Multiple control modules are possible in a DALI system Power supply via DALI line Fig. 1 Ø 86 5 46 Technical data Supply via DALI cable Current draw 6 ma from DALI Operating temperature 0... +50 C Storage temperature -25... +55 C Type of protection IP20 È Standards, page 3 Wiring diagrams and installation examples, page 3 Fig. 2 Fig. 3 Type Article number Figure Packaging, carton S2RC Remote ceiling 86459420 1 1 piece S2WM Wall mounted 86459421 2 1 piece S2SF Surface 86459419 3 1 piece 1

Specific technical data Type Ø of detection range, mounted at a height of 2.5 m Extension of the detection area1 Detection Swivel design Swivel range Detection angle Light measurement at the sensor head2 S2RC Remote ceiling 5 m 2 m yes ±15 360 10 650 lx 5 m S2WM Wall mounted 5 m 2 m yes ±15 360 10 650 lx 5 m S2SF Surface 5 m no 0 360 10 650 lx 5 m 1 If mounted at a height of 2.5 m and swivelled through 15. 2 The measured value at the sensor head corresponds to approx. 15 to 2,000 lux on the surface measured. Infra-red control range ACCES- SORIES 57 Optional infra-red remote control Switching on and off (On/Off button) Dimming (Up/Down button) Activating automatic lighting control (sun/cloud button) Calling up two scenes Calling up five fixed light output values (100, 50, 25, 12 and 6 %) Individual adjustment of the button assignments with configuration software Setting the threshold control point With wall bracket Type Article number Packaging, carton 86459423 (Tridonic) 96550422 (Thorn) 1 piece 119 ACCES- SORIES IR SMART Controller Optional infra-red remote control Switching on and off (On/Off button) Dimming (Up/Down button) Activation of automatic lighting control (Automatic button) Setting the threshold control point (Set button) Type Article number Packaging, carton DSI-SMART Controller 86451922 1 piece 2

The S2 is the ideal addition to the series of products as it offers daylight-dependent lighting control, presence detection and remote control. It has been designed for the following principal applications: Individual offices Open-plan offices Training / presentation rooms Corridors, passageways and garages The S2 controls a DALI group and is designed that it can be used together with the components (e.g. MC). For this reason the S2 can be addressed and grouped like an ECG, making system configuration easier. The configuration of the sensors is done by the masterconfigurator software tool (since version 2.02). For further information please refer to the S2 manual on www.tridonic.com. As an option, the S2 can be operated from two remote controls. The remote controls available with the system are: and IR-SMART Controller. A maximum of 12 sensors can be operated on one DALI circuit. This restriction is due to the permitted data traffic on the DALI circuit. To use the S2 in conjunction with an external system some modes are available. To ensure a proper function please take account of the advices in the S2 manual on www.tridonic.com. Wiring L N Standards EN 61547 EN 61347-1 EN 61347-2-11 EN 55015 PS2 PCA EXCEL one4all PCA EXCEL one4all S2 GC SC DALI USB Multiple sensors can be operated on a DALI circuit. The functions of the sensor can be activated autonomously or in a network of several sensors. Wiring type and cross section The wiring can be solid wire or stranded wire with a cross-section of 0.5 mm² to 1.5 mm². Remote control The S2 can be controlled with 2 remote controls: IR-SMART Controller DALI-RC wire preparation: 0.5 1.5 mm² 7.5 8.5 mm Installation The S2 must not be connected to the mains. It is supplied directly via the DALI signal line. A maximum of 12 S2 must be operated in one DALI circuit. DALI is not SELV. The installation instructions for mains voltage therefore apply. Please ensure that the detection range of the sensor lies in the lighting area of the controlled luminaires. Please ensure that the detection ranges of the sensors do not overlap. This may have influence to the lighting control. When installed at a height other than the recommended installation height (2,5m), the presence sensor might show different characteristics. When mounted at a higher level, its sensitivity is reduced. If mounted at a lower level, its range is diminished. Heaters, fans, printers and copiers located in the detection zone may cause incorrect presence detection. IR-SMART Controller ON Luminaire group ON UP Increase light value DOWN Reduce light value IR sender Automatic control mode ON/OFF SET saves the current light control value OFF Luminaire group OFF LED status display Light value 100 % brightness Light value 50 % brightness Light value 25 % brightness Light value 12 % brightness Light value 6 % brightness IR sender Switch all luminaires in the DALI system ON or OFF Increase or reduce the light value (dimming the DALI system) Automatic control mode ON Call up scene 2 Call up scene 1 3

Light level recognition area Motion detection h 70 h 90 d1 h * d1 d2 1.7 m 2.4 m 3.4 m 2.0 m 2.8 m 4.0 m 2.3 m 3.2 m 4.6 m 2.5 m 3.5 m 5.0 m 2.7 m 3.8 m 5.4 m 3.0 m 4.2 m 6.0 m 3.5 m 4.9 m 7.0 m 4.0 m 5.6 m 8.0 m d2 * The recommended maximum room height for office applications is 3 m and for corridor applications for example 4 m. Calculation of the diameter: d = 2 tan(0,5 a) h The following operating modes can be set for lighting control via the masterconfigurator configuration software: The following operating modes can be set for the motion detector via the masterconfigurator configuration software: Active Inactive Constant light control is active. Constant light control is deactivated. The lighting is switched on an adjustable light value. Setpoint adjustment IR-SMART Controller: Pressing the Set button stores the current light value as a new setpoint. DALI-RC: Holding down the Automatic button (> 3 s) stores the current light value as a new setpoint. masterconfigurator Active Off Only Never Off Inactive The light is switched on or off automatically depending on whether or not there is a person in the room. The motion detector only switches the connected lighting off. The luminaires are switched on manually via the connected external switch or infra-red control. If it has not detected any movement the sensor dims to the Absence value parameter and remains at this value The motion sensor is deactivated. The light must be switched on or off manually. Bright-out If the nominal illuminance (e.g. 500 lux) is exceeded for 10 minutes by more than 150 % (e.g. 750 lux), the lighting is switched off even if motion is detected. The lighting is switched on again when the measured light value falls below the setpoint. This function can be adjusted via the masterconfigurator. Run-on time This is the time after which the lighting is switched off if no movement is detected. It can be set via the Run-on time parameter. Absence value On the S2 you can set whether the light is to be switched off after the switch-off delay or dimmed to the second light value. The light value and the dwell time (how long the value is held) can be set via the Absence value and Switch-off delay parameters. Dead time Manual-off If the system is switched off manually via the switch or remote control the motion sensor is deactivated. At the end of a delay time if motion has not been detected the motion sensor is activated again. If the sensor detects motion during the Manual-off delay, the time will be reset to the start. 4

General settings Parameter Default Values Motion Detector enabled, on/off Light Regulation enabled Setpoint Light Regulation 150 lx Power On Setting no action Bright-out timeout 10 min Bright-out threshold 150 % Control Speed 4 Switch On Value auto (calculated) Rotary Switch 0, Broadcast Default Parameter Motion Detector Parameter Default Values 1 Fade-in time < 0.7 s A Presence value regulated 2 Run-on time 20 min 3 Fade time 5.6 s B Absence value 3 % 4 Switch-off delay 10 min 5 Fade-off time 5.6 s Manual-off 10 min Operating area (grouping) The setting of the operating area is done with the rotary switch which is at the backside of the S2. All devices in the setted operating area will be controlled by the sensor. Position Luminaire Group 0 Broadcast 1 DALI Group 0 2 DALI Group 1 3 DALI Group 2 4 DALI Group 3 S2SF Art. No. 96550419 5 DALI Group 4 ta: 0..50 C U1 = 16.0V DC tc: +60 C 13 6 DALI Group 5 86459419 D000 V0.00 000000 0000 7 DALI Group 6 8 DALI Group 7 9 DALI Group 8 A DALI Group 9 B DALI Group 10 C DALI Group 11 D DALI Group 12 E DALI Group 13 F DALI Group 14 DA DA 5