Brocade VDX Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit

Similar documents
Virtual Connect Enterprise Manager Server Guide

HP 36-Port InfiniBand Switch Cable Management Kit Installation Guide

Unpacking, Installation, and Customization

HP 16/18-Port Cable Management Kit Installation Guide

Switch Types, Blade IDs, and Product Names

Rack installation instructions

RM410. Hardware Installation Guide. Quick Start Guide. Rack Mounting Kit. Version 1.00 Edition 1, 12/2012

Rack Installation Instructions

Wall-Mounting your HP computer. User Guide

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

HP UPS R1500 Generation 3

RACKMUX-DRAWER Installation Manual For Drawer with 20 Inch LCD Monitor

ATS Overhead Table Shelf System INSTRUCTION MANUAL

February Fabric OS. Password Recovery Notes. Supporting Fabric OS v6.x, v5.x, v4.x, v3.x, v2.6.x

PS6500 Storage Arrays Rack Mount Instructions

Rack Installation Instructions

UPDATEUPDATEUPDATE. Converting the tower chassis to a rack-mount chassis. A - M To mount outer member to rack

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

December ServerIron ADX. Firewall Load Balancing Guide. Supporting Brocade ServerIron ADX version

Base Cabinet Assembly Instructions

SAN25 ( <00>)

MEDIUM FLAT PANEL DISPLAY STATIC MOUNT MSR Series

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

Front Panel Board Cable Replacement Instructions

4RU High Density Shelf Installation Instructions

DCF Optimized Rack System

UPGRADING AND SERVICING GUIDE

Installation Instructions

Required Supplies for Installing Check Tag Assembly

Installing Your 960 or 980 Server into a Rackmount Cabinet

Installation. Basic Rack Power Distribution Unit for Blade Servers

How To Install A Cisco Cisco 520-T1 Router On A Network Card (Cisco) With A Network Cable (Cio) And A Network (Cnet) (Coconc) (Net) And An Ipo (

Processor Cage Fans, Front and Rear Replacement Instructions

16/32 Channel 1U Rack Mount CCTV Power Supply

Small Flat Panel Lift Arm FSA-1004 and KSA-1004

BROCADE OPTICS FAMILY

Access Server Rack Cabinet Compatibility Guide

Acano solution. Acano Solution Installation Guide. Acano. January B

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

DE1600 DSA E-Series iscsi Disk Arrays. en Quick Install Guide

Brocade Network Advisor High Availability Using Microsoft Cluster Service

Fibre Channel over Ethernet: Enabling Server I/O Consolidation

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

NETWORK FUNCTIONS VIRTUALIZATION. The Top Five Virtualization Mistakes

POLEMOUNT FIELD FIX ASSEMBLY INSTRUCTIONS

UNPACKING AND ASSEMBLY

LIFT-505. BMF Lift Kit. Yamaha Drive Gas or Electric. Installation Instructions

HermanMiller Aeron Posturefit Installation AE905A AE905B AE905C

AMF112 ( <00>) 13mm (1/2 in.)

ilan Ethernet Box for 9100 Installation Manual

HP ProLiant DL380 G6 Carrier-Grade Server Read Before Install

BASCS in a Nutshell Study Guide for Exam Brocade University Revision

About the BitStorm 6051 POTS Splitter

12U Adjustable 4 Post Open Frame Server Rack

Step 1. Item 6. Item 1

AMF112 Instruction Manual

MCR1900 Media Converter 19-Slot Chassis

The Road to SDN: Software-Based Networking and Security from Brocade

R O A D M A S T E R, I N C.

RAIN COLLECTOR S HELF MANUAL

ECM-D70T / ECM-D70T1.5

42U/45U 28" Wide Rack Installation & Service Guide

SERVICE MANUAL. Corpus 3G. Seat system for electric wheelchair

R O A D M A S T E R, I N C.

Cascade Profiler Fibre Channel SAN Attached Storage Installation Guide. Version 8.2 March 2009

StorageWorks by Compaq

E2600 DSA E-Series iscsi Disk Arrays. en Quick Install Guide

GPS AutoSteer System Installation Manual

Replacing a Vantage Vue Transmitter

WARNING CANADIAN D.O.C. WARNING

430 Power/Electronics Replacement

HP ProLiant DL165 G7 Server. Installation Instructions

R O A D M A S T E R, I N C.

Power Supply Guide Version 1.0 for D-Show

OAK WORKBENCH WITH 2 DRAWERS

Brocade Network Advisor: CLI Configuration Manager

T360 Barbecue. Assembly Manual (G30531) Propane 1 YEAR LIMITED WARRANTY

Brocade SAN Scalability Guidelines: Brocade Fabric OS v7.x

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

Scale Computing Storage Cluster Installation Guide. Scale Computing 2121 S. El Camino Real San Mateo, CA

Part Name/Description Part Number Quantity. Power Cable

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

Dell E Series Monitor VESA Mounting Bracket Installation Instructions

R O A D M A S T E R, I N C.

How to Set Up Your NSM4000 Appliance

INSTALLATION INSTRUCTIONS Air Spring Kit Ford F250/F-350 Single Wheel 2WD Ford F350 Dually 2WD IMPORTANT NOTES

Owner s Manual Read and keep this manual. Patents World Wide

Brocade and McAfee Change the Secure Networking Landscape with High Performance at Lowest TCO

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: PN: L Rev. A

R O A D M A S T E R, I N C.

Brocade Fabric Vision Technology Frequently Asked Questions

ASSEMBLY INSTRUCTIONS Residential Roof solutions

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

TracRac G2. Overhead Rack Installation Instructions. TracRac Inc. 994 Jefferson St. FallRiver MA IN-42000_B

INSTRUCTIONS: LocknCharge Laptop Carts

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Brocade SAN Analytics Management Pack

Transcription:

53-1002671-01 22 August 2012 Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure Supporting the Brocade VDX 8770-4 switch 53-1002671-01 *53-1002671-01*

Copyright 2012 Brocade Communications Systems, Inc. All Rights Reserved. Brocade, Brocade Assurance, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, MLX, NetIron, SAN Health, ServerIron, TurboIron, VCS, and VDX are registered trademarks, and AnyIO, Brocade One, CloudPlex, Effortless Networking, ICX, NET Health, OpenScript, and The Effortless Network are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. Other brands, products, or service names mentioned may be trademarks of their respective owners. Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government. The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that accompany it. The product described by this document may contain open source software covered by the GNU General Public License or other open source license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd. Brocade Communications Systems, Incorporated Corporate and Latin American Headquarters Brocade Communications Systems, Inc. 130 Holger Way San Jose, CA 95134 Tel: 1-408-333-8000 Fax: 1-408-333-8101 E-mail: info@brocade.com European Headquarters Brocade Communications Switzerland Sàrl Centre Swissair Tour B - 4ème étage 29, Route de l'aéroport Case Postale 105 CH-1215 Genève 15 Switzerland Tel: +41 22 799 5640 Fax: +41 22 799 5641 E-mail: emea-info@brocade.com Asia-Pacific Headquarters Brocade Communications Systems China HK, Ltd. No. 1 Guanghua Road Chao Yang District Units 2718 and 2818 Beijing 100020, China Tel: +8610 6588 8888 Fax: +8610 6588 9999 E-mail: china-info@brocade.com Asia-Pacific Headquarters Brocade Communications Systems Co., Ltd. (Shenzhen WFOE) Citic Plaza No. 233 Tian He Road North Unit 1308 13th Floor Guangzhou, China Tel: +8620 3891 2000 Fax: +8620 3891 2111 E-mail: china-info@brocade.com Document History The following table lists all published versions of the Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure. Title Publication number Summary of changes Date Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure 53-1002671-01 New document. August 2012 2 of 20 Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure

Introduction Air flows into the Intake Air Duct Kit through the front vent and out through the fans at the rear of the unit. This document provides instructions to install a Intake Air Duct Kit in a 19 in. (48.26 cm) Electronic Industries Association (EIA) rack in either a flush or recessed configuration using the following Brocade Intake Air Duct Kit. Flush mount kit for rack rail-to-rail depth of 27 to 31 in. (68.58 to 78.74 cm). Recessed kit for rail-to-rail depth of 27 to 31 in. (68.58 to 78.74 cm) The document is organized as follows. Safety........................................................ 3 Installation guidelines........................................... 3 Preparing to install the Intake Air Duct Kit in a four-post rack........... 3 Safety Observe the caution notice in this manual. The caution notice has an ID, which is displayed in parentheses (C015). Use this ID to locate the translation of this caution notice in the Brocade Product Safety Notices. CAUTION Use safe lifting practices when moving the product. (C015) NOTE A fully populated Intake Air Duct Kit weighs 86.18kg (190lbs) and requires a hydraulic or assisted lift to install it. Installation guidelines ATTENTION To ensure adequate cooling, install the switch with the air intake (port side) facing the cool-air aisle. Follow these general installation guidelines: The shelf in the kit is 2U high, so you need a total of 10U of rack space to install the shelf and the Intake Air Duct Kit. 1U is equal to 8.90 cm (3.50 in.). To allow the quick removal of all power from the switch, use AC power sources that are easily accessible and located near the switch. Verify that the additional weight of the switch does not exceed the weight limits of the rack. Plan for cable management before installing the switch. Cables can be managed in a variety of ways, such as by routing cables to either side of the switch, through cable channels on the sides of the rack, or using patch panels. Refer to the Brocade VDX 8770-4 Hardware Reference Manual for specific information. Preparing to install the Intake Air Duct Kit in a four-post rack Use the following instructions to install the Intake Air Duct Kit in a four-post rack. There are two variations on the Intake Air Duct Kit depending on whether you need to have the port side of the switch recessed or flush mounted. Instructions for the variations appear as follows. Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure 3 of 20

Installing the flush mount Intake Air Duct kit......................... 4 Installing the recessed mount Intake Air Duct kit..................... 11 Time required Allow approximately one hour to unpack and install the air duct kit in a rack. Tools required The following tools are required when installing the air duct kit: Torque wrench with #2 Phillips screwdriver tip Flathead screwdriver Installing the flush mount Intake Air Duct kit Use the following procedures to install the Intake Air Duct Kit in a four-post rack with rail-to-rail depth of 27 to 31 in.(68.58 to 78.74 cm). Parts list See Figure 1 on page 5 for the parts list for the flush mount version. 4 of 20 Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure

1 Shelf 6 10-32 x.63 in.(1.60 cm) Phillips screw with square cone washer for racks that have rails with round holes (18) 2 Duct 7 10-32 clip nut for racks that have rails with round holes (14) 3 Air filter 8 10-32 retainer nut for racks that have rails with square holes (14) 4 Top rail 9 Alignment washer for racks that have rails with square holes (4) 5 10-32 x.31 in. (.79 cm) Phillips screw with blue Loctite on threads (16) 10 6-32 x.25 in. (.635 cm) Phillips screw (2) FIGURE 1 Flush mount Intake Air Duct Kit assembly for a four-post rack ATTENTION This hardware kit is a universal kit, and some hardware will not be used in this installation. Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure 5 of 20

Torque requirements Use the following torque settings when tightening screws that secure the rack mount kit and Intake Air Duct Kit to the equipment rack. TABLE 1 Screw size Torque requirements for mounting screws Torque 6-32 x.25 in. (.635 cm) Phillips screw 10-32 x.63 in.(1.60 cm) Phillips screw 8.75 in-lb (10 cm-kg) 32 in-lb (36.86 cm-kg) Install the rack hardware 1. Unpack the Intake Air Duct Kit. 2. Determine how the switch can be oriented in the equipment rack so that the port side has access to intake (cool) air. 3. Install either clip nuts or retainer nuts depending on whether your rack has round holes or square holes. These will allow you to secure the switch to the rack posts. NOTE For posts with round holes, use the clip nuts on the rack uprights for securing M6 x 1.0 x 12 screws. For posts with square holes, use the retainer nuts. Refer to Figure 2. 1 3 4 2 1 Clip nuts 3 Retainer nut 2 Round hole rack rail 4 Square hole rack rail FIGURE 2 Using clip nuts or retainer nuts to secure screws to the rack posts 4. Install the shelf (Figure 3). 6 of 20 Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure

a. The shelf can be adjusted to a length of between 27 and 31 inches (68.58 and 78.74 cm) to accommodate your rack size. To lengthen or shorten the shelf, loosen the four 6-32 screws in the four slots on the shelf (see Figure 1 on page 5) and adjust the shelf to the desired length. Once adjusted, tighten the four 6-32 screws. b. Secure the shelf to the rack with eight 10-32 screws with washers, two screws in each corner of the shelf (see Figure 3). Tighten the screws according to specifications under Torque requirements on page 6. Use the 10-32 x.63 in. (1.60 cm) Phillips screws with square cone washers to secure the shelf. 1 Shelf 2 Screw locations FIGURE 3 Shelf installed in the rack 5. Install the duct by inserting it down into the side slot on the shelf. Ensure that the tabs of the duct align and engage with the slots in the shelf. Refer to Figure 4. Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure 7 of 20

1 Duct 2 Shelf FIGURE 4 Installing the duct into the side slot of the shelf 6. Install the top rail assembly to the duct (Figure 5). a. The top rail assembly can be adjusted to a length of between 27 and 31 inches (68.58 to 78.74 cm) to fit on the inside of the rack rails. To lengthen or shorten the top rail assembly, loosen the two 6-32 screws and adjust the top rail assembly to the desired length. The length will be approximately the length of the adjustable shelf. b. Insert the top rail assembly down into the duct and then secure the top rail assembly to the duct with two 6-32 screws, one screw on each side of the duct. Tighten the screws according to specifications under Torque requirements on page 6. 8 of 20 Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure

1 Top rail assembly 3 6-32 x.25 in. (.635 cm) Phillips screw 2 Duct 4 10-32 Phillips screw locations FIGURE 5 Securing the top rail in the rack (rear view) 7. Secure the top rail assembly to the rack with four 10-32 screws, two screws on each end of the top rail assembly. For rails with round holes, use two 10-32 screws with washers (see Figure 1 on page 5) on each end of the top rail assembly. Tighten the screws according to specifications under Torque requirements on page 6. For rails with square holes, use the two standard 10-32 screws (see Figure 1 on page 5) with blue Loctite on the threads and alignment washers (see Figure 1 on page 5) on each end of the top rail assembly. Tighten the screws according to specifications under Torque requirements on page 6. 8. Tighten the 6-32 screws to hold the length adjustment of the top rail. Install the switch in the rack 1. Use a lift to raise the switch to the correct level. CAUTION Use safe lifting practices when moving the product. (C015) 2. If applicable, lock the wheels of the lift. 3. Carefully lift the switch and slide it into the rack. Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure 9 of 20

4. Secure the switch to the rack with six 10-32 screws with washers. Refer to Figure 6. Tighten the screws according to specifications under Torque requirements on page 6. Use the 10-32 x.63 in.(1.60 cm) Phillips screws with square cone washers to secure the switch. Use either 10-32 retainer nut for racks that have rails with square holes or 10-32 clip nut for racks that have rails with round holes to retain screws. NOTE Screws, clip nuts, and retainer nuts to secure the switch to the rack are provided in the hardware accessory kit that accompanies the switch. 1 Screw locations for mounting switch FIGURE 6 Switch with Intake Air Duct Kit installed in the rack (DCX-4S shown, VDX 8770-4 similar) NOTE For rails with round holes, use the clip nuts (see Figure 1 on page 5) on the rails for securing the 10-32 screws. For rails with square holes, use the retainer nuts (see Figure 1 on page 5). 5. If desired, install the air filter to the air intake grill using the five captive screws. Refer to Figure 7. 10 of 20 Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure

1 Air filter with captive screws FIGURE 7 Flush mounted Brocade VDX 8770-4 with the air filter installed 6. Install the cable management system using instructions in the Brocade VDX 8770-4 Hardware Reference Manual. Installing the recessed mount Intake Air Duct kit Use the following procedures to install the Intake Air Duct Kit in a rack with rail-to-rail depth of 27 to 31 in.(68.58 to 78.74 cm) and the front of the switch recessed. Parts list See Figure 8 on page 12 for the parts list for the recessed mount version. (the correct graphic is not yet available) Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure 11 of 20

1 Shelf 7 10-32 x.31 in. (.79 cm) Phillips screw with blue Loctite on threads (16) 2 Duct 8 10-32 x.63 in.(1.60 cm) Phillips screw with square cone washer for racks that have rails with round holes (18) 3 Top rail 9 10-32 clip nut for racks that have rails with round holes (14) 4 Left recessed rack ear 10 10-32 retainer nut for racks that have rails with square holes (14) 5 Right recessed rack ear 11 Alignment washer for racks that have rails with square holes (4) 6 Air filter 12 6-32 x.25 in. (.635 cm) Phillips screw (2) FIGURE 8 Recessed mount Intake Air Duct Kit assembly for a four-post rack 12 of 20 Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure

ATTENTION This hardware kit is a universal kit, and some hardware will not be used in this installation. Torque requirements Use the following torque settings when tightening screws that secure the Intake Air Duct Kit to the equipment rack. TABLE 2 Screw size Torque requirements for mounting screws Torque 6-32 x.25 in. (.635 cm) Phillips screw 10-32 x.63 in.(1.60 cm) Phillips screw 8.75 in-lb (10 cm-kg) 32 in-lb (36.86 cm-kg) Install the rack hardware 1. Unpack the Intake Air Duct Kit. 2. Determine how the switch can be oriented in the equipment rack so that the port side has access to intake (cool) air. 3. Install either clip nuts or retainer nuts depending on whether your rack has round holes or square holes. These will allow you to secure the switch to the rack posts. NOTE For posts with round holes, use the clip nuts on the rack uprights for securing M6 x 1.0 x 12 screws. For posts with square holes, use the retainer nuts. Refer to Figure 9. 1 3 4 2 1 Clip nuts 3 Retainer nut 2 Round hole rack rail 4 Square hole rack rail FIGURE 9 Using clip nuts or retainer nuts to secure screws to the rack posts 4. Install the shelf (Figure 10). Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure 13 of 20

a. The shelf can be adjusted to a length of between 27 and 31 inches (68.58 and 78.74 cm) to accommodate your rack size. To lengthen or shorten the shelf, loosen the four 6-32 screws in the four slots on the shelf (see Figure 8 on page 12) and adjust the shelf to the desired length. Once adjusted, tighten the four 6-32 screws. b. Secure the shelf to the rack with eight 10-32 screws with washers, two screws in each corner of the shelf (see Figure 10). Tighten the screws according to specifications under Torque requirements on page 13. Use the 10-32 x.63 in. (1.60 cm) Phillips screws with square cone washers to secure the shelf. 1 Shelf 2 Screw locations FIGURE 10 Shelf installed in the rack 5. Install the duct by inserting it down into the side slot on the shelf. Ensure that the tabs of the duct align and engage with the slots in the shelf. Refer to Figure 11. 14 of 20 Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure

1 Duct 2 Shelf FIGURE 11 Installing air duct into side slot on shelf 6. Install the top rail assembly to the duct (Figure 12). a. The top rail assembly can be adjusted to a length of between 27 and 31 inches (68.58 to 78.74 cm) to fit on the inside of the rack rails. To lengthen or shorten the top rail assembly, loosen the two 6-32 screws and adjust the top rail assembly to the desired length. The length will be approximately the length of the adjustable shelf. Once adjusted, tighten the two 6-32 screws. b. Insert the top rail assembly down into the duct and then secure the top rail assembly to the duct with two 6-32 screws, one screw on each side of the duct. Tighten the screws according to specifications under Torque requirements on page 13. Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure 15 of 20

1 Top rail assembly 3 6-32 x.25 in. (.635 cm) Phillips screw 2 Duct 4 10-32 Phillips screw locations FIGURE 12 Securing the top rail in the rack (rear view) 7. Secure the top rail assembly to the rack with four 10-32 screws, two screws on each end of the top rail assembly. For rails with round holes, use two 10-32 screws with washers (see Figure 8) on each end of the top rail assembly. Tighten the screws according to specifications under Torque requirements.. For rails with square holes, use the two standard 10-32 screws (see Figure 8) with blue Loctite on the threads and alignment washers (see Figure 8) on each end of the top rail assembly. Tighten the screws according to specifications under Torque requirements. 8. Tighten the 6-32 screws to hold the length adjustment of the top rail. Install the switch in the rack 1. Install the recessed rack ears on the switch. Refer to Figure 13. Note how one bracket has openings to accommodate the intake perforations. 16 of 20 Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure

1 Switch 3 Recessed rack ears 2 Screw locations (opposite side similar) FIGURE 13 Adding the recessed rack ears. 2. Use a lift to raise the switch to the correct level. CAUTION Use safe lifting practices when moving the product. (C015) 3. If applicable, lock the wheels of the lift. 4. Carefully lift the switch and slide it into the rack. Refer to Figure 14. 5. Secure the switch to the rack with six 10-32 screws and retainer or clip nuts. Tighten the screws according to specifications under Torque requirements.. Use the 10-32 x.63 in.(1.60 cm) Phillips screws with square cone washers to secure the switch. Use either 10-32 retainer nut for racks that have rails with square holes or 10-32 clip nut for racks that have rails with round holes to retain screws. NOTE Screws, clip nuts, and retainer nuts to secure the switch to the rack are provided in the hardware accessory kit that accompanies the switch. Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure 17 of 20

1 Screw locations for mounting switch FIGURE 14 Brocade VDX 8770-4 with the Intake Air Duct Kit installed in the rack in a recessed configuration NOTE For rails with round holes, use the clip nuts on the rails for securing the 10-32 screws. For rails with square holes, use the retainer nuts. Refer to Figure 8 on page 12. 6. If desired, install the air filter to the air intake grill using the five captive screws. Refer to Figure 15. 18 of 20 Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure

1 Air filter with captive screws FIGURE 15 Recess mounted Brocade VDX 8770-4 with the air filter installed 7. Install the cable management system using instructions in the Brocade VDX 8770-4 Hardware Reference Manual. Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure 19 of 20

20 of 20 Brocade VDX 8770-4 Four-Post Flush and Recessed Mount Intake Air Duct Rack Kit Installation Procedure