THE PRISM SPECTROMETER

Similar documents
WAVELENGTH OF LIGHT - DIFFRACTION GRATING

GRID AND PRISM SPECTROMETERS

ATOMIC SPECTRA. Apparatus: Optical spectrometer, spectral tubes, power supply, incandescent lamp, bottles of dyed water, elevating jack or block.

THE BOHR QUANTUM MODEL

O6: The Diffraction Grating Spectrometer

Experiment #12: The Bohr Atom. Equipment: Spectroscope Hydrogen and Helium Gas Discharge Tubes, Holder, and Variac Flashlight

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

Light and its effects

Chapter 17: Light and Image Formation

Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1

CALIBRATION FOR LAL20X & LAL24X

Refraction of Light at a Plane Surface. Object: To study the refraction of light from water into air, at a plane surface.

Building your own Spectroscope

Interference. Physics 102 Workshop #3. General Instructions

Basic Optics System OS-8515C

Theremino System Theremino Spectrometer Technology

After a wave passes through a medium, how does the position of that medium compare to its original position?

What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher)

Name Date Class ELECTRONS IN ATOMS. Standard Curriculum Core content Extension topics

Review Vocabulary spectrum: a range of values or properties

1 Laboratory #5: Grating Spectrometer

THE NATURE OF LIGHT AND COLOR

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

Reflection and Refraction

ILLUSTRATIVE EXAMPLE: Given: A = 3 and B = 4 if we now want the value of C=? C = = = 25 or 2

The Electromagnetic Spectrum

Lenses and Telescopes

Procedure: Geometrical Optics. Theory Refer to your Lab Manual, pages Equipment Needed

Experiment #5: Qualitative Absorption Spectroscopy

From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation?

THE COMPOUND MICROSCOPE

Melting Point, Boiling Point, and Index of Refraction

STAAR Science Tutorial 30 TEK 8.8C: Electromagnetic Waves

Blackbody Radiation References INTRODUCTION

Solution Derivations for Capa #14

Using the Spectrophotometer

Science In Action 8 Unit C - Light and Optical Systems. 1.1 The Challenge of light

LIGHT SECTION 6-REFRACTION-BENDING LIGHT From Hands on Science by Linda Poore, 2003.

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

RAY OPTICS II 7.1 INTRODUCTION

Study Guide for Exam on Light

Light Telescopes. Grade Level: class periods (more if in-depth research occurs)

Light as a Wave. The Nature of Light. EM Radiation Spectrum. EM Radiation Spectrum. Electromagnetic Radiation

Polarization of Light

Experiment IV: Atomic Spectra and the Bohr model

12.1 What is Refraction pg Light travels in straight lines through air. What happens to light when it travels from one material into another?

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Physics 41, Winter 1998 Lab 1 - The Current Balance. Theory

Third Grade Light and Optics Assessment

6) How wide must a narrow slit be if the first diffraction minimum occurs at ±12 with laser light of 633 nm?

Alignement of a ring cavity laser

Experiment 5. Lasers and laser mode structure

Atoms Absorb & Emit Light

1 of 9 2/9/2010 3:38 PM

WAVES AND ELECTROMAGNETIC RADIATION

Experiment #2: Determining Sugar Content of a Drink. Objective. Introduction

Mirror, mirror - Teacher Guide

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

CPI Links Content Guide & Five Items Resource

Experiment 3 Lenses and Images

1. Three-Color Light. Introduction to Three-Color Light. Chapter 1. Adding Color Pigments. Difference Between Pigments and Light. Adding Color Light

Experiment 2 Index of refraction of an unknown liquid --- Abbe Refractometer

FirstView 3 Reflector Telescope Owner s Manual

PHYA2. General Certificate of Education Advanced Subsidiary Examination June Mechanics, Materials and Waves

Waves Sound and Light

Teacher s Resource. 2. The student will see the images reversed left to right.

About Coffee and Refractometers Voice Systems Technology, Inc. (VST)

Geometric Optics Converging Lenses and Mirrors Physics Lab IV

Cosmic Journey: Teacher Packet

- the. or may. scales on. Butterfly wing. magnified about 75 times.

waves rays Consider rays of light from an object being reflected by a plane mirror (the rays are diverging): mirror object

Modeling the Expanding Universe

Measuring the Doppler Shift of a Kepler Star with a Planet

Physics 10. Lecture 29A. "There are two ways of spreading light: to be the candle or the mirror that reflects it." --Edith Wharton

SURFACE TENSION. Definition

2 Spectrophotometry and the Analysis of Riboflavin

Physical Properties of a Pure Substance, Water

9/16 Optics 1 /11 GEOMETRIC OPTICS

EXPERIMENT O-6. Michelson Interferometer. Abstract. References. Pre-Lab

Rubber Band Race Car

E/M Experiment: Electrons in a Magnetic Field.

Your first. Buying a scope for the first time can be daunting. We reveal what you shoud look for and how to get up and running.

Electronics and Soldering Notes

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

Energy - Heat, Light, and Sound

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

PTYS/ASTR 206 Section 2 Spring 2007 Homework #2 (Page 1/5) NAME: KEY

ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES

Physics 25 Exam 3 November 3, 2009

Name Class Date Laboratory Investigation 4B Chapter 4: Cell Structure

Convex Mirrors. Ray Diagram for Convex Mirror

Interferometers. OBJECTIVES To examine the operation of several kinds of interferometers. d sin = n (1)

Torque and Rotary Motion

Chapter 1 Parts C. Robert Bagnell, Jr., Ph.D., 2012

Microscope Lab Introduction to the Microscope Lab Activity

Alpy guiding User Guide. Olivier Thizy François Cochard

Care and Use of the Compound Microscope

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40

Transcription:

OBJECTIVES: THE PRISM SPECTROMETER 1) Learn the theory of the prism spectrometer, and be able to explain the functions of its various components. 2) Observe the spectrum of a mercury discharge lamp and record the angle of deviation for the spectral lines. 3) Determine the index of refraction of a glass prism for various wavelengths. 4) Use the calibrated prism to measure unknown wavelengths. 5) Observe color sensation caused by light of particular wavelengths. INTRODUCTION: When a beam of light is transmitted from air to glass, the ray is bent according to Snell's law sin θ air = n sin θ glass (1) where the angles are measured from the surface normal (the line perpendicular to the surface) and n is the index of refraction of the glass. The index of refraction is a dimension-less number and is a measure of how strongly the medium bends light. The greater n is, the more the light is bent. The index of refraction of air is 1. For glass, n varies from 1.3 to 1.8, depending on the type of glass and on the wavelength of the light. air θ glass θ air glass White light is made up of all the colors of the rainbow - red, yellow, green, blue, and violet. Different colors correspond to different wavelengths. Human eyes are sensitive to light with wavelengths in the range 390 nm (violet) to 750 nm (red) (1 nm = nanometer = 10-9 m). 300nm 400 500 600 700 wavelength(nm) ultraviolet violet indigo blue green yellow red Range of human vision infrared 1

n = Introductory Physics Experiments (Physics 252, v4.0) Glass has a greater index of refraction at shorter wavelengths, that is, it bends blue light more than red light. So a prism can be used to disperse white light into its component colors. white red blue n blue red wavelength λ In this experiment, we will use a prism spectrometer to measure the dispersion angle of various wavelengths. From the measurements, we will make a graph of the index of refraction vs. wavelength. The form of the curve of index of refraction as a function of wavelength, known as the Cauchy formula, is n = A + B/λ 2 Or n = A + (b/λ) 2 ***In the introduction for your lab, find B in terms of b, and solve the first equation for l, given n, A, and B*** As a light source, we will use a mercury lamp, which emits light at several discrete wavelengths. The device we are using is called a prism spectrometer because, once the prism is calibrated, it can be used to measure the wavelengths of the lines in the spectra produced by various atoms. The spectra contain bright lines at particular wavelengths, which correspond to light emitted during the transition between different energy states of the atoms. You see distinct lines because the atoms exist only in distinct, quantized energy states. Trying to explain the data from such experiments the existence and pattern of sharp spectral lines led to the development of quantum mechanics. When a ray of light is refracted by a prism, the angle between the incoming and outgoing rays is called the angle of deviation (β). For a given prism and a given wavelength, the value of β depends on the angle between the incoming ray and the surface of the prism. β is minimum when the angles of the incoming and outgoing rays make equal angles with the prism surfaces. In this special symmetric case, the prism's index of refraction (n) is related to β and the apex angle of the prism (α) by α + β sin 2 n = α sin 2 The prisms that we will use all have α = 60 (exactly, we assume). (2) 2

The Prism Spectrometer (Version 4.0, 1/7/2002) apex angle α δmin δ > δ min Angle of minimum deviation Angle of deviation greater than minimum There exist extensive tables of the line spectra of many elements. In the first part of the experiment, you will be using the known spectrum of mercury to calibrate your prism spectrometer. As a result, you have measured the curve of index of refraction as a function of wavelength. So if you measure a new line of a spectrum, you can calculate the index of refraction and use your curve to look up the wavelength for the new line. This process is used in identifying the elements present in unknown samples, such as the atmospheres of distant stars. The element helium, now used to inflate birthday balloons, was first discovered by observing the atmosphere of a nearby the star, the sun (helios is Greek for sun). In the last part of the experiment you will have the opportunity to measure the spectrum of a gas in this fashion. The fine prism spectrometers used in this lab were purchased in 1970 for $700 each. Today (1996), inferior models are available for $1700. Handle them with respect! Never force any parts! 3

4 Introductory Physics Experiments (Physics 252, v4.0)

The Prism Spectrometer (Version 4.0, 1/7/2002) Partner Name Section Black Table Rotate black table when adjusting for zero angle Prism table δ slit Collimator Telescope Focus Hg lamp Slit motion for focus Read angle δ with vernier scale Eye PROCEDURE 1. Become familiar with the spectrometer a) Identify each component: the black table, the prism table, the collimator, and the telescope (see figure above). b) Note the clamping screws and the fine adjustment screws for the telescope and the black table. Note the clamping screw for the prism table. c) Note how to adjust the telescope focus and the eyepiece. d) Note how to adjust the slit focusing in the collimator tube. Note how the slit width can be adjusted and how the slit orientation can be rotated. 5

Introductory Physics Experiments (Physics 252, v4.0) 2. Practice reading the angle from a precise protractor scale on the rim of the black table. Use the Vernier scale with the little magnifying glass to read the angle to the nearest arc minute. (1 arcmin = 1' = 1/ 60 degree.) The following is an example: 0 10 20 30 40 50 In this example, the zero line of the Vernier scale (the upper scale) is between 40.5 and 41, so the angle is somewhere between 40 30' and 41. The Vernier scale tells exactly where in between. Look along the Vernier for the line that exactly lines up with the line below it. In this case, it's the 17' line. So the angle is 40 47', which we get by adding 17' to 40 30'. Before using this angle in equation (2), we must convert it to decimal degrees: 40 + (47/60) degrees = 40.78. 3. Align the spectrometer In order to correctly measure angles with the spectrometer, we must first align it. To do so, use the following steps: a) Telescope focus: Do not put the prism onto the silver table yet. That will come later. Notice that there are two knobs associated with the telescope. They are located directly under the telescope barrel. One points along the barrel and one is perpendicular to it. The knob that is along the barrel will lock the telescope s position and will prevent it from rotating. When it is locked down in this way, you can use the other knob for a fine adjustment, to rotate it by very small amounts. If the telescope is not unlocked, turn the knob that is parallel to the barrel counterclockwise until you can freely rotate the telescope. Turn the telescope so that it is not pointing at the collimator but is instead aimed at something as far away from you in the room as possible. Now rotate the focus adjustment (see diagram on page 5) until you can see through the telescope clearly. You may notice that the image is upside down. This is normal. Just ensure that it is as clear and in focus as you can. After this adjustment, you should not adjust the focus of the telescope again. b) Telescope alignment: Now place a white light (desk lamp) in front of the slit on the end of the collimator (in the diagram on page 5, the desk lamp goes where the HG lamp is pictured). Now rotate the telescope until it is pointed at the collimator. You should imagine 6

The Prism Spectrometer (Version 4.0, 1/7/2002) a straight line going from the lamp through the collimator, and through the telescope. By looking through the telescope, you should be able to line up the crosshair with the slit in the far end of the collimator. By locking down the telescope and using the fine adjustment (the knob perpendicular to the one that you used to lock down the telescope) you should be able to do this very accurately. If you are unable to see the slit, it may be closed too tightly. You can widen and narrow the slit by rotating the adjuster on the collimator (it is located on the far end of the collimator, much like the focus for the telescope). This will adjust the slit width, but will not focus the slit. If the slit does not have very crisp edges when you look through the telescope, move the end of the collimator near the lamp in and out to focus it. If your slit is not vertical in the telescope, you can also rotate it so that it is. Once you have a nice thin, well-focused slit, with your crosshairs centered on it and your telescope locked down, you are now ready to align the scales to read the angle. c) Angle adjustment: If you look below the set of knobs that control the telescope, you will see another pair of knobs that look identical to the ones for the telescope. These knobs perform the same functions (locking down and fine adjustment) for the black table itself. If you unlock the black table, you can rotate it. Notice that there are two windows in which you can read an angle. We want to rotate the table until one of the windows has 0 (zero) lined up with 0 (zero) or 360 (since a circle is 360 degrees, 360 is the same as 180. If at all possible, we should try to use set it so that this window is to the left of the telescope (as we are looking over the barrel toward the lamp) because this will make reading our angle easiest. (please have a look at the diagram on page 5) On some scopes there is a small magnifier attached to the black table over one window, and this would also be advantageous to use. Once you have aligned them, you will lock down the black table and will not rotate it again. From now on, we will only rotate the telescope. d) Prism placement: Now you should place the prism in the center of the silver table. Recall that light is bent toward the base of the prism, so it should be placed on the silver table so that the gray plastic part makes a C shape if you were to look at it from the telescope side of the apparatus. Now, without moving the telescope, move your head to the left (about to where the telescope is rotated to in the diagram on page 5) and look into the prism. You will have to put your head down at the height of the telescope/collimator. Now rotate the silver table clockwise until you can see a nice rainbow like spectrum inside the prism. (You should notice that the rainbow is inside of a black circle. You are seeing the light coming out of the collimator and bent through the prism.) If it does not look like a very nice, bright, well formed rainbow, you probably do not have your head in the right place; move further left and try to rotate the silver table back and forth. Once you have found it, unlock the telescope (not the black table) and rotate it to the left where you were looking. Now look through the telescope, and you should be able to find the rainbow. We are now in about the right place to find our spectrum with the mercury vapor lamp and to adjust for the minimum angle of deviation. 7

Introductory Physics Experiments (Physics 252, v4.0) e) Minimum angle of deviation: Now, remove the white light and replace it with the mercury vapor lamp. You will want to move the lamp until it is aligned with the slit. To do this, look through the telescope and move the lamp back and forth until it is nice and bright in the telescope. Instead of a complete rainbow, you should now see only certain bands of color. If your bands do not look nice and sharp, you may have to adjust your slit focus or width. Some lines are better seen if you tighten the slit. (The lamp should be very close to the slit.) Move the telescope back and forth until you get the crosshair lined up on the green band. Now look back to the diagram on page 5. We want to make the angle β as small as possible. To do this, rotate the silver table back and forth just a little bit. You should be able to get the green line to move to the right. Now realign the crosshair on the green line and rotate the silver table a little bit again. Then realign the crosshair on the green line. You should repeat this process until no matter which way you rotate the silver table, the green line goes to the left, not the right. When this occurs, and the green line is as far as you can get it to go to the right, you are at the minimum angle of deviation. This angle should be around 51 or 52 degrees for the green line. If it is not, you may not have aligned the scales correctly, please repeat steps c, d, and e from above. (Record it below). Every time that you do a different color, you will have to repeat this process. f) Record the prism number and read the deviation angle on the protractor. Prism # β = = 4. Measure the angle of deviation for each of the spectral lines of the Mercury lamp. The wavelengths and colors of the spectral lines are given in the table below. While making measurements, unclamp and rotate the prism table to check that the prism is oriented for minimum angle of deviation for the red, green, and blue lines. When measuring very closely spaced lines, like the double yellow lines, make the slit very narrow and check the focus. When measuring dim lines, make the slit wider. 5. To calculate the quantity of 1/λ 2, you should convert l from nm to mm first, then do the calculation. That way, you are guaranteed to have the units correct. Calculate the index of refraction (n) for each spectral line using equation (2). Keep four digits after the decimal point. Write down the equation you will use for calculating the index of refraction. 8

The Prism Spectrometer (Version 4.0, 1/7/2002) Prism apex angle α =60 color wavelength λ (nm) red 690.8 yellow 1 579.1 yellow 2 577.0 green 546.1 blue-green (dim) 491.6 blue 435.8 violet 404.7 1/λ 2 (µm) 2 angle of deviation β (deg,min) (decimal deg) Index of refraction 6. Make a graph of n vs. λ. 7. Make a graph of n vs. 1/λ 2 and find a best straight line fit to the graph. Calculate the slope and the y-intercept. 9

Introductory Physics Experiments (Physics 252, v4.0) 8. Observe the spectral lines of another emission lamp. For any three bright lines in the spectrum, record the perceived color and intensity, measure the angle of deviation (β), and calculate the index of refraction (n). Now look back to your graph of n vs. 1/λ 2. This graph told us how light of a certain wavelength was bent by our prism. Since we are using the same prism in this part of the experiment, this data can be used to help us. We can (and have) calculated a slope and a y-intercept from this graph. We know the equation of a straight line and we can compare that equation to the equation which reads: n = A + B/λ 2. Or, put another way: y = b + m * x n = A + B * (1/λ 2 ) Using this, we can calculate 1/λ 2 from the slope, y-intercept and the index of refraction (n). Type of lamp: color intensity (dim, bright ) angle of deviation β (deg., min.) (dec. deg.) Index n 1/λ 2 (µm) 2 Wavelength λ (nm) 10