Supplementary Installation and Operating Instructions BM 100 A KROHNE 07/2000

Similar documents
Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

Siemens AG Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.

Introduction to PROFIBUS and PROFINET

Siemens S7 PLC and FC 300 Profibus

Lecture 4 Profibus. Urban Bilstrup Urban.Bilstrup@ide.hh.se

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Research of PROFIBUS PA s integration in PROFINET IO

PROCESS AUTOMATION PLANNING AND INTEGRATION INFORMATION LB8106* Integration in Siemens SIMATIC PCS 7

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

AC 800M PROFIBUS DP Installation

CPB. Doc. N MO-0279-ING MODBUS/PROFIBUS DP CONVERTER TYPE CPB. Microener - Copyright 2010 Date Rev. 0

PROFIBUS DPV0. Manual / Users Guide. Gateways & Encoders. Part No , Doc. No Ver. 01

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

PROFIBUS fault finding and health checking

G3 Series PROFIBUS DP Technical Manual

I.S. 1 remote I/O system Redundant coupling via PROFIBUS DP

Continuous PROFIBUS PA Instruments and Step 7. Configuring a Siemens Continuous Level PROFIBUS PA device in a S7-300 or S7-400 PLC

TURCK Modular Industrial I/O PROFIBUS -DP Products

Modbus and ION Technology

M-Bus Network Installation Notes

GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0

Everything you ever wanted to know about DPV1 diagnostics but were afraid to ask!

Modular I/O System Analog and Digital Interface Modules

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

1 Application Description Objective Goals... 3

DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual

Using a Modbus TCP to Profibus PA Gateway by IFAK system

Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G

Bus modules systron PM

SIMATIC. ET 200S distributed I/O 2AI U ST analog electronic module (6ES7134-4FB01-0AB0) Preface. Properties 1. Parameters 2.

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

CB15/CB155. PROFIBUS Module

S-series DeviceNet Interface Card

Automation Unit TM 1703 ACP Flexible automation and telecontrol

PROFIBUS / MODBUS GATEWAY Application Note for Communication between Premium CPU & XPS-MC Safety Controllers

User Manuals. Connection to Siemens S5 PU (AS511) Part Number: Version: 2. Date:

CMC-PD01 PROFIBUS DP Slave Communication Card Operation Manual

Modbus and ION Technology

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Model Q46 Profibus Communications Manual

SIMATIC NET. CP AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program

Development of a Gateway to PROFIBUS for Remote Diagnostics

USER S MANUAL. Profibus Option Card For Toshiba VF-S11 Inverter

ABB Drives. User s Manual HTL Encoder Interface FEN-31

S7 for Windows S7-300/400

PROFIBUS. Installation Guideline. for Planning

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Application about Communication

Configuring PROFINET

MINIMAT-EC-Servo Screwdriver Spindles

The Answer to the 14 Most Frequently Asked Modbus Questions

GW-7552 PRIFIBUS/MODBUS GATEWAY

BNI EIP Z009 IP67 Module, Unmanaged Switch

Non-Isolated Analog Voltage/Current Output module IC695ALG704 provides four configurable voltage or current output channels. Isolated +24 VDC Power

Parameterizing options Parameterization options based on the communication protocols used

PROFIBUS. Design and. Good Practices

AN : Using Wago CANOpen IO

DCREG INTERFACE VIA DEVICENET

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Adding a Modbus TCP Device to the Network. Setting Up Your Network

Redundancy Module QUINT-DIODE/40

Overview and Applications of PROFINET. Andy Verwer Verwer Training & Consultancy Ltd

Configuration a Profibus-DP node using Step7 and WAGO-I/O components Application note

Omron I/O Driver (Series 2) Programmable Serial Interface Card

Technical Data. Dimensions

SOFTLINK 300. CPU Specifications. Reference Manual

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents

CPUs - CPU PN/DP

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2

ROC Protocol Specifications Manual

Manual. MOVIDRIVE MDX61B MOVI-PLC DHP11B Control Card. Edition 09/2005 FA / EN

PCS0100en Persy Control Services B.V. Netherlands

SITRANS F M MAGFLO. Electromagnetic flowmeters Signal converter types MAG 5000, MAG Manual *083R9141* Order no.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Permissible ambient temperature Operation Storage, transport

3DLevelScanner II TECHNICAL DATA SHEET

IFC 070 Technical Datasheet

NMEA 0183 INSTALLATION AND OPERATING GUIDELINES

ABB industrial drives. Quick start-up guide Drive Manager for SIMATIC

S and STEP 7 Basic V10.5

PROFIBUS AND MODBUS: A COMPARISON

Hirschmann Networking Interoperability in a

1.Eastron SDM220Modbus Smart Meter Modbus Protocol Implementation V1.0

The CP FO provides access to different communication services of the PROFIBUS bus system:

CPU PN/DP. Function

Profinet to EDV111 Series LED Signs Siemens Function Block Software Manual

Dupline Car Park System Type GP x 724-US 3-Colour Ultrasonic Sensor

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE E05

deltapilot S Electronic Insert FEB 24 (P) with PROFIBUS-PA Protocol

Current Loop Application Note 1495

Components for industrial communication. Lenze Global Drive Providing the connection

Programmable Controller G Series. New. Models

Manual. Fieldbus Interface DFP21B PROFIBUS DP-V1. Edition 07/2006 FA / EN

Transcription:

KROHNE 07/2000 Supplementary Installation and Operating Instructions BM 100 A KROHNE Messtechnik GmbH & Co. KG Ludwig-Krohne-Str. 5 R D-47058 Duisburg 1/7

Contents: GENERAL...3 ITEMS INCLUDED WITH SUPPLY...3 SOFTWARE HISTORY...3 1. PROFIBUS-PA...3 1.1 PROFIBUS-PA - SERVICES...4 1.2 NETWORK CONFIGURATION...4 1.2.1 GSD file...4 1.2.2 Cyclic data exchange...4 1.3 MEANING OF MEASUREMENT AND STATUS INFORMATION...5 2. ELECTRICAL CONNECTION...6 2.1 INTERCONNECTION OF DEVICES IN THE HAZARDOUS LOCATION...6 2.2 BUS CABLE...6 2.3 SHIELDING AND GROUNDING...6 2.4 PROFIBUS-PA CONNECTION...7 3. MENU SETTINGS FOR PROFIBUS-PA...7 4. TECHNICAL DATA, PROFIBUS IDENT-NO. EE01...7 KROHNE Messtechnik GmbH & Co. KG Ludwig-Krohne-Str. 5 R D-47058 Duisburg 2/7

,30)/& 1 2 3 4 5 6,30)/& 1 2 3 4 5 6 kg/ h 10 00 90 0 80 0 70 0 60 0 50 0 40 0 30 0 20 0 10 0 RP kg,30)/& H250 SN 58 6677/ 01-03 MC H2 50/RR/M 9/ K2/ ESK- Z C K25. 21. 4571 F CI V 251. 4571 MD 1997 C2H50 D 0.93 H kg/l V 2.5 m Pa.s T 23. 5 C P 0.4 M Pa FIA 10 25 General Supplementary documentation BM 100 A with PROFIBUS-PA These Instructions are supplementary to the Installation and Operating Instructions (Reference Manual) BM 100 A / BM 100EEX. The details given there, in particular the Safety Information, are valid and should be observed. These Supplementary Instructions provide only additional information for device operation and connection to a PROFIBUS- PA fieldbus. Attention: Please set the controller to manual mode before changing parameters of the BM 100 A. Items included with supply In addition to the standard scope of supply, these Supplementary Instructions for the BM 100 A with PROFIBUS-PA interface plus a diskette with the available Profibus device data files (GSD files) of all KROHNE devices. Software history Issued Signal converter User program Instructions month/year Hardware Firmware Hardware Operating system Software Device User program 07/00 PROFIBUS- PA Module 1. PROFIBUS-PA 2.02/000406 12/96+Suppleme nt 07/00 Control system (PLC) Class 1 master Engineering or operation control tool Class 2 master Analog I/O module PROFIBUS-DP, up to 12 Mbit/s Power Supply Segment coupler/link Segment coupler/link PROFIBUS-PA PROFIBUS-PA 4-20 ma HART device The above diagram shows a typical instrumentation with PROFIBUS-PA devices in hazardous and non-hazardous locations, including connection of conventional devices (e.g. with 4-20mA signals) to the PROFIBUS-PA. The PROFIBUS-PA is normally connected to a segment coupler which, among other things, carries out the conversion to the PROFIBUS-DP. Here, it needs to be noted in particular that the segment coupler is normally set to a fixed baud rate on the DP side. Further information on the planning and operation of PROFIBUS-PA networks is to be found in the KROHNE brochure PROFIBUS-PA networks. KROHNE Messtechnik GmbH & Co. KG Ludwig-Krohne-Str. 5 R D-47058 Duisburg 3/7

1.1 PROFIBUS-PA - Services The BM100A supports the following PROFIBUS services which have been defined in the PROFIBUS-PA-Profil V3.0: 1. DDLM_Set_Slave_Add 2. DDLM_Get_Cfg 3. DDLM_Set_Prm 4. DDLM_Chk_Cfg 5. DDLM_Slave_Diag 6. DDLM_Data_Exchange Those services are able to set the PROFIBUS station address (1), to configure the data telegramm for the cyclic data exchange (3/4). The actual PROFIBUS configuration (2) and the Diagnostic data can be read (5). The cyclic data exchange (6) allows to transmit the measurement data to a master. All measurement data are considered as virtuell modules of Type Analog Input (AI). 1.2 Network Configuration 1.2.1 GSD file All available GSD files of KROHNE devices including those of the BM 100 A, of course - are supplied together with each device. The GSD contains information that is needed for project planning of the PROFIBUS-DP/PA communication network. The relevant data files must be loaded into the network configuration system before start-up of the bus system. For example, the following applies to COMET 200 or COM PROFIBUS from Siemens: all GSD files (*.GSD) into the directory of the GSD files, e.g. *\GSD all BMP files (*.BMP) into the directory of the bit maps, e.g. *\BITMAPS In STEP7, the GSD file is automatically copied into the respective directory with install new GSD. After that, the bit map file must be copied into the directory *\SIEMENS\STEP7\S7data\Nsbmp. Following catalog updating the device can be placed in the project. This will then enable the cyclic communication (measured values and status). 1.2.2 Cyclic data exchange During network configuration the user has to define which measurement values of the BM100A should be transfered cyclicly to the master. The following measurement data are available in this order: 1. Volume/Level * and Status 2. Level und Status 3. Distance and Status 4. Ullage Volume ** and Status 5. Interface Volume **/*** and Status 6. Interface Level *** and Status 7. Interface Distance *** and Status 8. Interface Layer *** and Status (*) Volume will only be transmitted if the Volume Table has been programmed. If the Volume Table is missing both the first and second value (module) is Level. (**) This module is only available if the Volume Table has been programmed. If the Volume Table is missing the value "Not_a_Number" will be transmitted. The status is "Bad-Out of Service". (***) This module is only available if the Interface option has been activated in the device. If the Interface option is not available the value "Not_a_Number" (0x7FFFFFFF) will be transmitted. The status is "Bad-Out of Service". Network configuration will be done by a master tool. using the GSD file. It is freely choosable which of the above mentioned measurement values (modules) should be transmitted cyclicly. All those measurement values which should be transmitted an Analog Input Function Block (AI-FB) should be assigned to. The code is 0x94. Some masters need the so called Extended Format. Please use 0x42, 0x84, 0x08, 0x05 instead of 0x94. Those measurement values which should not be transmitted an empty module has to be assigned to. The code is 0x00. All following modules will move one module (5 Bytes) forward. The order of modules remain the same. If for example Volume and Interface Level has been configured, 10 Bytes will be transmitted only. KROHNE Messtechnik GmbH & Co. KG Ludwig-Krohne-Str. 5 R D-47058 Duisburg 4/7

Units Independent from the units within the local operating display Level and Distance values will be transmitted in m always. Depending from the volume table Volume will be transmitted as cubic metres (m3) or tons (t). 1.3 Meaning of measurement and status information Each configured measurement value is a 4 Byte Float Format according IEEE Standard 754 Short Real Number. A status byte follows each measurement value. That means each measurement value consists of 4 byte value plus 1 byte status. Other measurement values will directly follow as 5 Byte package if configured. First an example of the float format: Float Format Byte n Byte n+1 Byte n+2 Byte n+3 Bit7 Bit6 Bit7 Bit6 Bit7 Bit7 VZ 2 7 2 6 2 5 2 4 2 3 2 2 2 1 2 0 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8 2-9 2-10 2-11 2-12 2-13 2-14 2-15 2-16 2-17 2-18 2-19 2-20 2-21 2-22 2-23 Exponent Mantissa Mantissa Mantissa Example: 40 F0 00 00 (hex) = 0100 0000 1111 0000 0000 0000 0000 0000 (binary) Calculation: Value = (-1) VZ * 2 (Exponent - 127) * (1 + Mantissa) Value = (-1) 0 * 2 (129-127) * (1 + 2-1 + 2-2 + 2-3 ) Value = 1 * 4 * (1 + 0,5 + 0,25 + 0,125) = 7,5 Status (1 Byte) Quality Quality-Substatus Limits Gr Gr QS QS QS QS Qu Qu 2 7 2 6 2 5 2 4 2 3 2 2 2 1 2 0 0 0 = bad 0 1 = uncertain 1 0 = good (Non Cascade) Status = bad 0 0 0 0 0 1 = configuration error 0 0 0 0 1 1 = device failure 0 0 0 1 0 0 = sensor failure 0 0 0 1 1 1 = out of service Status = uncertain 0 1 0 0 0 1 = last usable value 0 1 0 0 1 1 = initial value (value before first measurement) 0 1 0 1 1 0 = sub-normal (appears if level or interface level has been frozen) Status = good 1 0 0 0 0 0 = ok 1 0 1 0 0 1 = maintenance required Status = Limits 0 0 = ok 0 1 = low limited 1 0 = high limited 1 1 = constant Check the first two quality bits in order to get the quality information of the measurement value: Good (non Cascade) measurement value is ok and can be used without restrictions Uncertain measurement value can be used but the accuracy can not be guaranteed (e.g. measurement value has been frozen or A/D converter is saturated) Bad measurement value is bad don t use it The Quality-Substatus - and Limit -Bits can be used for further diagnostics or limit checking. Attention: The status should be watched always because a valid number will be transmitted even if the status of the measurement is bad or uncertain. This is the only chance to check the meaning of the transmitted measurement values. KROHNE Messtechnik GmbH & Co. KG Ludwig-Krohne-Str. 5 R D-47058 Duisburg 5/7

Diagnostics If the device has detected an error, additional diagnostic information will be send to the master. The meaning of the additional information is described within the GSD file under UNIT_DIAG_BIT(i). 2. Electrical connection For a detailed description please check the Installation and Operating Instructions manual of the device. 2.1 Interconnection of devices in the hazardous location We recommend that a PROFIBUS-PA network in the hazardous location be projected in accordance with PTB s FISCO model (see KROHNE brochure PROFIBUS-PA networks ). The FISCO-Model may be used, if: all electrical components which should be connected to the bus must be approved according the FISCO model (even the termination), the maximum cable length does not exceed 1000 m, the values of the cable are within the following ranges R =15...150Ω/km; L =0,4...1mH/km; C =80...200nF/km, the approved input values of the field devices (Uo, Io, Po) are matchable with the output values of the power supply (e.g. segmment coupler) which menas UI Uo, II Io und PI Po. 2.2 Bus cable Further limitations to the cable than the FISCO limitations are not existent. Nevertheless a twisted pair and shielded cable strongly recommended. The good quality cable could have the following data: 44Ω/km, <90nF/km, <3dB attenuation at 39kHz and 100 Ohm impedance at 31,25kHz. 2.3 Shielding and grounding For optimum electromagnetic compatibility of systems it is extremely important that the system components, and particularly the bus cables connecting the components, be shielded and that such shields - if possible - form an unbroken cover, electrically speaking. Hence it follows that, for use in non-hazardous duty systems, the cable shield should be grounded as often as possible. In Ex systems an adequate equipotential bonding in the hazardous and non-hazardous location along the entire fieldbus installation is strongly recommended. Multiple grounding of the shield is also of advantage. Note: The use of twisted and shielded cables is strongly recommended, otherwise EMC protection of the BM 100 A cannot be assured. KROHNE Messtechnik GmbH & Co. KG Ludwig-Krohne-Str. 5 R D-47058 Duisburg 6/7

2.4 PROFIBUS-PA connection Connect the bus cable as shown in the figure. Connect cable cores to terminals 4 and 4.1. Polarity reversal will not have any effect. The cable shield should be connected with minimum length to the ground PE. PROFIBUS-PA with Current Output The equipotential bonding conductor must be connected to the device, if necessary via the outer U-clamp ground terminal. Current Output Fieldbus Power Supply 5 6 4 4.1 4.2 11 12 Shield - + 4-20mA U=8-30V PROFIBUS- PA PE 3. Menu settings for PROFIBUS-PA For a detailed description please check the Installation and Operating Instructions manual of the device. The following settings need to be made for operation of the BM 100 A on a PROFIBUS-PA network. Note that the service set slave address is not being supported. Therefore the address can only be set by way of the local display and operator interface. Function (Fct.) Input range Description 1.6.1 BAUDRATE Select 19200 Bd. This is the baudrate of the internal communication interface of the device (not PROFIBUS-PA). The value must not be changed. 1.6.2 ADDRESS Input 0... 126 Settings out of the range will be ignored. If out of range 126 will be used as default value. Address can be changed via local display or via Profibus. The Profibus address can be changed via the Profibus service Set_Slave_Address. The input range is 0...125 according to the Profibus specification. Address 126 is the default address and cannot be set via Profibus. 4. Technical data, PROFIBUS Ident-No. EE01 Hardware Physical Bus characteristics Base current FDE Fault current Starting current Ex approval Connection to IEC 61158-2 and the FISCO model 9... 30 V; 0.3 A max. ; 4.2 W max. 10 ma yes: separate fault disconnection electronics provided 6 ma; (fault current = max. continuous current base current) lower than base current EEx ia IIC T6 or EEx ib IIC/IIB T6 in conformity with the FISCO model independent of polarity Software GSD all KROHNE GSD files supplied on diskette Device profile complete implementation of Profile B, V2.0 Functional blocks level [m], distance [m], in addition volume [m 3 ] as cyclic value plus status mentioned units are default units Address range 0-126, default 126, set slave address not supported Operator control local display and operator interface at device SAP`s 1; typically the number of service access points is equal to the number of class 2 masters (operating tools) which can be operated simultaneously KROHNE Messtechnik GmbH & Co. KG Ludwig-Krohne-Str. 5 R D-47058 Duisburg 7/7