TURCK Modular Industrial I/O PROFIBUS -DP Products
|
|
|
- Albert McDaniel
- 9 years ago
- Views:
Transcription
1 TURCK Modular Industrial I/O PROFIBUS -DP Products Piconet Gateways Rugged, Fully Potted Stations IP 67 Protection Small Footprint Automatic Baud Rate Sensing SDPL-0404D-0003 SDPL-0404D-0004 SDPL-0404D-1003 SDPL-0404D-1004 Electrical Operating Current: <75 ma plus sensor currents (from U B Sensor Current: <500 ma total of all sensors (from U B Output Current: <500 ma per output (from U L Power Distribution Inputs: U B Power supply Outputs: U L Power supply Mechanical Operating Temperature: 0 to +55 C (+32 to +131 F Protection: IP 67 Vibration: IEC 68, part 2-6 Material Connectors: Nickel-plated brass Housing: Nylon Diagnostics (Physical One LED indicates an I/O fault for the entire station LEDs to indicate status of PROFIBUS-DP communication PROFIBUS eurofast Pinouts Male Female 5-Pin 1 = 5 VDC 2 = BUS_A 3 = Gnd 5-Pin 4 = BUS_B 5 = Shield and have both male and female PROFIBUS-DP connectors Aux. Power picofast Male picofast Female 4-Pin 1 = U B + 2 = U L + 4-Pin 3 = Gnd 4 = Gnd K65
2 Industrial Automation Inputs Outputs Data Part Number Input Count Pinout Connectors Inputs per Connector Sensor Style Group Diagnostics Wire-Break Detection Individual Diagnostics Output Count Connectors SDPL-0404D PI 1 PNP PO A 1 SDPL-0404D S 2 PNP G A 1 SDPL-0404D PI 1 PNP PO A 1 SDPL-0404D S 1 PNP G A 1 Pinout Outputs per Connector Current Wire-Break Detection Individual Diagnostics I/O Map Input/Output Connectors 2S 2G PI Mating cordset: RK 4.4T-*-RS 4.4T Splitter: VBRS 4.4-2RK 4T-*/* Mating cordset: RK 4.4T-*-RS 4.4T Splitter: VBRS 4.4-2RK 4T-*/* Mating cordset: PSG 3M-* PROFIBUS-DP PO Mating cordset: PSG 3M-* I/O Data Map 1 In Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 0 Out 0 Data from next input modules Data for next output modules I-3 I-2 I-1 I-0 O-3 O-2 O-1 O-0 K66
3 TURCK Modular Industrial I/O PROFIBUS -DP Products PROFIBUS-DP to AS-interface Gateways AS-I systems can be easily connected to a higher-level network, like PROFIBUS, through a gateway master. The gateway acts as a master to the AS-I system(s and a slave to the PROFIBUS system, mapping all of the AS-I data for PROFIBUS in a single block. For AS-I specifications and rating details see section E of this catalog. PROFIBUS-DP System (Gateway is the Slave AS-I System (Gateway is the Master K67
4 Industrial Automation Addressing PROFIBUS stations must have a network address for communication. The address for AS-I/ PROFIBUS gateways may be set via the on-unit display and push buttons. Please consult the manual for a particular gateway for instruction on the procedure. Diagnostics AS-I/ PROFIBUS gateways contain LEDs for diagnosing I/O and communication problems for AS-I and PROFIBUS. For a detailed description of the LED states please see the Bihl+Wiedemann AS-I/ PROFIBUS Gateway User Manual available for download from Power Most AS-I/ PROFIBUS gateways draw power from the AS-I power supply. The option to use a separate, non-as-i power supply is also available. Consult the gateway documentation to ensure that the gateway being selected meets the requirements of your system. PROFIBUS-DP K68
5 TURCK Modular Industrial I/O PROFIBUS -DP Products AS-I Profibus-DP Gateways in Stainless Steel AS-I v3.0 Supported Graphical Display Integrated Ground-Fault Detection Integrated AS-I Diagnostics ASI-DPG-SS BW1567* ASI-DPG-SS BW1568* ASI-DPG-SS BW1569* ASI-DPG-SS-SE BW1773* ASI-DPG-SS-SE BW1774* ASI-DPG-SS-C1D2 BW1653 ASI-DPG-SS-C1D2 BW1654 ASI-DPG-SS-C1D2 BW1655 * Not ETL Listed Electrical Operating Current: 200 ma from V AS-I (Power Supply A 200 ma from V AS-i1, 70mA from V AS-i2 (Power Supply A2 250 ma from V AUX (Power Supply E Power Distribution From AS-I supply for each network (Power Supply A, A2 From external supply (Power Supply E Mechanical Operating Temperature: 0 to +55 C (+32 to +131 F Protection: IP 20 Material Housing: Stainless Steel Diagnostics (Logical Health of AS-I network is available via Proximus-DP interface Diagnostics (Physical LED to indicate status of network and AS-I communication and power supply PROFIBUS-DP Connector 1 = Shield 3 = BUS_B 5 = DGnd 6 = +5 VDC 8 = BUS_A K69
6 Industrial Automation Part Number Higher Level Network ASI-DPG-SS BW1567 PROFIBUS-DP A X X ASI-DPG-SS BW1568 PROFIBUS-DP A X X ASI-DPG-SS BW1569 PROFIBUS-DP E X X Power Style AS-I Version ASI-DPG-SS-SE BW1773 PROFIBUS-DP A ASI-DPG-SS-SE BW1774 PROFIBUS-DP A ASI-DPG-SS-C1D2 BW1653 PROFIBUS-DP A ASI-DPG-SS-C1D2 BW1654 PROFIBUS-DP A ASI-DPG-SS-C1D2 BW1655 PROFIBUS-DP E #ofas-i Masters Duplicate Address Detection Programming Interface A A2 E PROFIBUS-DP A - Single AS-I network is powered by and AS-I power supply A2 - Dual AS-I networks are each powered by their own AS-I power supply E - Dual AS-I networks are both powered by a single 30 VDC supply, decoupled through the gateway K70
7 TURCK Modular Industrial I/O PROFIBUS -DP Products AS-I PROFIBUS-D Economy Gateways AS-I v3.0 Supported LED Display PROFIBUS-DP Support Integrated AS-I Diagnostics Electrical Operating Current: <300 ma from AS-I Power Distribution From AS-I supply Mechanical Operating Temperature: 0 to +55 C (+32 to +131 F Protection: IP 20 Material Housing: Stainless Steel Diagnostics (Logical AS-I diagnostic data is available via Network interface Diagnostics (Physical LEDs to indicate status of network and AS-I communication and power supply ASI-DPG-SS-B BW1746 PROFIBUS-DP Connector 1 = Shield 3 = BUS_B 5 = DGnd 6 = +5 VDC 8 = BUS_A K71
8 Industrial Automation Part Number Higher Level Network ASI-DPB-SS BW1746 PROFIBUS-DP A 2.1 A 1 Power Style AS-I Version Connection Diagram #ofas-i Masters A PROFIBUS-DP K72
9 TURCK Modular Industrial I/O PROFIBUS -DP Products AS-I PROFIBUS-DP Gateways AS-I v2.1 Supported 2-Digit Display Electrical IP 65 Protection Integrated AS-I Diagnostics Operating Current: 200 ma from V AS-I ASI-DPG BW1253 ASI-DPG BW1371 Power Distribution From AS-I supply for each network Mechanical Operating Temperature: 0 to +55 C (+32 to +131 F Protection: IP 65 Material Housing: Plastic Diagnostics (Logical Health of AS-I network is available via Network interface Diagnostics (Physical LEDs to indicate status of network and AS-I communication and power supply PROFIBUS eurofast Pinouts 1 = 5 VDC* 2 = BUS _A 3 = Gnd 4 = BUS_B 5 = Shield * Female connector only Female 5-Pin BW1371 only K73
10 Industrial Automation Part Number Higher Level Network Power Style AS-I Version Connection Diagram ASI-DPG BW1253 PROFIBUS-DP A ASI-DPG BW1371 PROFIBUS-DP A #ofas-i Masters Duplicate Address Detection Programming Interface A - Single AS-I network is powered by and AS-I power supply 1 PROFIBUS-DP 1 BUS_A 2 BUS_B 3 BUS_A 4 BUS_B 5 0V 6 Shield 7 FG (Function Gnd 8 FG (Function Gnd 9 Shield 10 +5V Note: AS-I connections are made via standard AS-I base modules ASI-BM BW1180 or ASI-BM BW1182 (see p. E K74
11 TURCK Modular Industrial I/O PROFIBUS -DP Products BL67 Gateway Modular I/O Fieldbus Independent Configuration IP 67 Protection Various I/O Styles Electrical BL67-GW-DP Operating Current: <50 ma from V I Supply Current: <10 A to I/O (from V I and V O Backplane Current: <1.5 A (from V I Mechanical Operating Temperature: -25 to +55 C (+32 to +131 F Protection: IP 67 Vibration: Hz Material Housing: PC-V0 (Lexan Diagnostics (Logical Diagnostic information available through the PROFIBUS-DP interface Diagnostics (Physical LEDs to indicate status of PROFIBUS-DP and Module Bus communication PROFIBUS eurofast Pinouts 1 = 5 VDC* Male Female 2 = BUS _A 3 = Gnd 4 = BUS_B 5 = Shield * Female connector only 5-Pin 5-Pin minifast Power Pinouts Male 1 = Gnd 2 = Gnd 3 = PE 4 = V I 5 = V O 5-Pin Note: Power feeding modules may be used for I/O current supply to prevent overloading the gateway power supply. K75
12 Industrial Automation PROFIBUS -DP BL67 Stations TURCK's BL67 is a modular, user configurable network I/O system designed to allow installation of nodes containing different types and sizes of I/O depending on the users needs for a particular area. Featuring IP 67 protection and metal threaded connectors, the BL67 can often be mounted in the physical process environment or directly on a machine without a separate enclosure for the I/O. This saves planning and installation time, as well as the cost of the enclosure itself. The BL67 system supports several different network protocols, including PROFIBUS-DP. A BL67 station consists of a gateway module that interfaces to the PROFIBUS system, and several I/O modules that interface with the physical I/O in the field. Different connector options are available to allow a greater level of customization to the user. For more details on the BL67 system, please see section G of this catalog. TURCK's I/O Assistant software package is used to configure the BL67 system. PROFIBUS-DP K76
13 TURCK Modular Industrial I/O PROFIBUS -DP Products BL20 Gateway Modular I/O Fieldbus Independent Configuration IP 20 Protection Various I/O Styles BL20-GWBR-PBDP Electrical Operating Current: <430 ma from BR power supply (U SYS Supply Current: <10 A to I/O (from U L <1.5 A to backplane (from U SYS Mechanical Operating Temperature: 0 to +55 C (+32 to +131 F Protection: IP 20 Vibration: Hz Material Housing: PC-V0 (Lexan Diagnostics (Logical Diagnostic information available through the PROFIBUS-DP interface Diagnostics (Physical LEDs to indicate status of PROFIBUS-DP and Module Bus communication Power Connectors PROFIBUS-DP Connector 1 = Shield 3 = BUS_B 5 = Gnd 6 = +VDC 8 = BUS_A K77
14 Industrial Automation PROFIBUS -DP BL20 Stations TURCK's BL20 is a modular, user configurable network I/O system designed to allow installation of nodes containing different types and sizes of I/O depending on the users needs for a particular area. Featuring IP 20 protection and terminal point connections, the BL20 is intended to be mounted in the control cabinet or in a field enclosure. The BL20 system supports several different network protocols, including PROFIBUS-DP. A BL20 station consists of a gateway module that interfaces to the PROFIBUS system, and several I/O modules that interface with the physical I/O in the field. The terminal bases are available with tension clamp or screw terminal connector types. For more details on the BL20 system, please see section H of this catalog. TURCK's I/O Assistant software package is used to configure the BL20 system. PROFIBUS-DP K78
DeviceNet, Panel Mount Junction Box
DeviceNet, Panel Mount Junction Box DIN Rail Junction Box Open Style Removable Terminals Part Number Application Wiring Diagrams JRBS-57-4 JRBS-57-6 Open style DIN mounted junction box JRBS-57-8 Specifications
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master
Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master Page 1 of 13 Table of Contents 1 OVERVIEW... 3 2 INSTALLING AND CONFIGURING THE ANYBUS -X GENERIC GATEWAY AND ETHERNET
G3 Series PROFIBUS DP Technical Manual
G3 Series PROFIBUS DP Technical 3835063 A - Table of Contents PAGE About PROFIBUS-DP...3 Overview...3 G3 PROFIBUS-DP Features...3 Cabling and Drop Line Lengths (as defined by PROFIBUS specification)...3
DeviceNet, minifast Conduit Adapters
DeviceNet, minifast Conduit Adapters Gasket and Mounting Screws Provided Same Housing Style for Single or Double Port Housing Part Number Specs Application Pinout BCA 57-M123 conduit body* for transition
AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP
Product Information Gateway For Connecting EnDat Encoders to PROFIBUS-DP April 2012 PROFIBUS Gateway For Connecting EnDat Encoders Encoders with EnDat interface for connection via gateway All absolute
Set for Profibus DPV1 in IP20 TI-BL20-DPV1-8
Type code Ident no. 1545007 Number of channels 8 Dimensions (W x L x H) 110.3 x 128.9 x 74.4 mm Cable max. 50 m between interface and read/write head 2 decimal rotary coding switches for the adjustment
AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor
AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous
Install the DeviceNet Module using the following procedure:
Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from
TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector
Product datasheet Characteristics TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC - 0.5 A - M8 connector Main Range of product Product or component type Range compatibility Enclosure material Bus
Compact multiprotocol I/O module for Ethernet 8 digital PNP inputs and 8 digital PNP outputs 2 A TBEN-L1-8DIP-8DOP
EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet switch Supports 10 Mbps/100 Mbps 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection 7/8" males, 5-pin, for power supply Separated power
4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G 3891 0020
Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G 3891 0020 Built-in Dupline channel generator PROFIBUS-DP slave according to EN 50 170 Certified by the PNO PROFIBUS-DP communication
Set for PROFINET IO in IP20 TI-BL20-EN-PN-4
Cable max. 50 m between interface and read/write head Connection of up to 4 read/write heads via BL ident extension cables Mixed operation of HF and UHF read/ write heads Connectors /S2500 Type code Ident
Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8
CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection
SmartWire Panel Wiring Solutions the easy way to connect
SmartWire Panel Wiring Solutions the easy way to connect Richard Chung SmartWire Program Manager Milwaukee, WI 2008 Eaton Corporation. All rights reserved. SmartWire Panel Wiring Solution Key Customer
Introduction to the Actuator Sensor-Interface
Introduction to the Actuator Sensor-Interface Andy Verwer Automation Systems Centre, Manchester Metropolitan University Outline of Presentation Introduction to the Actuator-Sensor Interface,. Characteristics
Siemens AG 2010. Fieldbus solutions with the SIMATIC PCS 7 distributed control system. Brochure April 2010 SIMATIC PCS 7. Answers for industry.
Fieldbus solutions with the SIMATIC PCS 7 distributed control system Brochure April 2010 SIMATIC PCS 7 Answers for industry. Fieldbus solutions with SIMATIC PCS 7 OS multi-clients Engineering station Maintenance/
CPU systron S 200 - S 250 - S 250c. systron S 200 - S 250 - S 250c. CPUs to the process modules. Stand-alone PLC
E031019 000823 systron S 200 - S 250 - S 250c CPU systron S 200 - S 250 - S 250c 45 mm width Flexible and expandable Easy to use software for bus connection (S 250/ S 250c) CPUs to the process modules
Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.
Preliminary TECHNICAL DATASHEET #TDAX020700 HYDRAULIC VALVE CONTROLLER 24 I/O 5 Analog and 6 Digital Inputs 1 Temperature Sensor and 1 RPM Sensor Interface 2 PWM Inputs 6 Proportional and 4 ON/OFF Current
Introduction to PROFIBUS and PROFINET
Introduction to PROFIBUS and PROFINET Andy Verwer Technical Officer for PROFIBUS UK Verwer Training & Consultancy Ltd Gold distributor PROFIBUS Characteristics PROFIBUS is a bi-directional digital communication
Inductive sensor NI10-M18-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Threaded barrel, M18 x 1 Chrome-plated brass DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6 (NA- MUR) M12
40.3. Control Relays and Timers
.3 Contents EASY500/700/800 Intelligent Relays........ EASY/MFD Expansion Modules............ MFD Intelligent Relays................... EASY/MFD Communication Modules....... EASY/MFD Power Supplies, Accessories
Lecture 4 Profibus. Urban Bilstrup [email protected]
Lecture 4 Profibus Urban Bilstrup [email protected] Profibus Outline Introduction Profibus-DP Physical Layer Link Layer Application Layer 2 Profibus Introduction Three different versions of PROFIBUS
CPB. Doc. N MO-0279-ING MODBUS/PROFIBUS DP CONVERTER TYPE CPB. Microener - Copyright 2010 Date 20.12.2004 Rev. 0
MODBUS/PROFIBUS DP CONVERTER TYPE CPB Microener - Copyright 2010 Date 20.12.2004 Rev. 0 INDEX 1. GENERAL 3 2. CPB SET 4 3. INSTALLATION 4 3.1 - CPB CONVERTER ASSEMBLING 4 3.2 - PROFIBUS TERMINAL DESCRIPTION.
General 1-2-Opto-electronics Safety Switches 4-Emergency
General 1-2-Opto-electronics Safety Switches 4-Emergency Logic Power The Lifeline 4 cable/push button operated system can be installed along or around awkward machinery such as conveyors and provide a
AN00140-003: Using Wago CANOpen IO
AN00140-003: Using Wago CANOpen IO Overview Baldor now offers WAGO Modular IO Systems for use with Mint Motion Controllers using the CANOpen field bus interface. The WAGO units provide a very flexible
Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University
Practical steps for a successful PROFIBUS Project Presented by Dr. Xiu Ji Manchester Metropolitan University Basics of PROFIBUS Content Practical steps in the design and installation stages Segmentation:
IBS IP I/O Gateway. Data Sheet INTERBUS-S. Coupling Module for Two InterBus-S Lines
IBS IP I/O Gateway Courtesy of Steven Engineering, Inc. 230 Ryan Way, South San Francisco, CA, 94080-6370 Main Office: (650) 588-9200 Outside Local Area: (800) 258-9200 www.stevenengineering.com Data Sheet
AS-i 3.0 Gateways, PROFIsafe via PROFINET or PROFIBUS
via PROFINET or AS-i 3.0 Gateways, via PROFINET or 2 / 1 Master, PROFINET / Slave AS-i Safety input slaves report via AS-i Safety output slaves switch via 1 Safety Monitor for 2 AS-i networks Operation
Automation Unit TM 1703 ACP Flexible automation and telecontrol
Automation Unit Flexible automation and telecontrol Power Transmission and Distribution Outstanding performance: Automate simply with Highly complex and yet fully transparent automation solutions are not
S-series SQ Controller
DeltaV Distributed Control System Product Data Sheet December 2015 S-series SQ Controller Scalable controllers Quick assembly Easy-to-use Field proven architecture Designed for Electonic Marshalling Advanced
IFEA Industriell kommunikasjon. AS-i Training
IFEA Industriell kommunikasjon 1 Agenda AS-i safety basics Safety Output ASIMON 3G2 Current Devices Troubleshooting Safety 2 3 4 AS-i Safety at Work 5 Safety at work - Headlines Integration of all binary
L5354 ControlNet Communications Interface
L5354 ControlNet Communications Interface Technical Manual HA470733 Issue 2 Copyright SSD Drives Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or
S-series DeviceNet Interface Card
January 2013 Page 1 The DeltaV provides the solution for interfacing to discrete actuators and sensors. Offers freedom to choose appropriate bus for application Supports standard device-level busses Reduces
with Electronic Assistant
TECHNICAL DATASHEET #TDAX100200 BLDC Motor Drive Drives a 12V, 24V or 48V BLDC motor Bidirectional, up to 25A Smooth speed control using Hall Sensors CAN (SAE J1939) with Electronic Assistant Features:
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q605 0054 R0001
Analogue Input, -fold, MDRC, GH Q605 005 R0001 The analogue input is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via the bus connecting terminal supplied.
The CP 342-5 FO provides access to different communication services of the PROFIBUS bus system:
CP 342-5 FO Function The CP 342-5 FO provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61 158/61784, master or slave) PG/OP communication S7
BL compact multiprotocol station for Industrial Ethernet SSI interface BLCEN-1M12MT-1SSI
Compact fieldbus I/O module in IP69K EtherNet/IP, Modbus TCP, or PROFINET slave Integrated Ethernet switch 10 Mbps / 100 Mbps Two males M12, 4-pin, D-coded, for fieldbus connection 2 rotary switches for
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
M-series Virtual I/O Module 2
DeltaV Distributed Control System Product Data Sheet M-series Virtual I/O Module 2 Non-intrusive DeltaV I/O simulation Powerful integration solution Easy to use Modular, flexible packaging The M-series
Technical data. General specifications. Signal voltage 15... 30 V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.
Model Number Features Very small housing High climatic resistance 4 Bit multiturn Analog output Surge and reverse polarity protection Description This absolute rotary encoder with internal magnetic sampling
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5
Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service program ULTRA 000 programmable switch outputs Hysteresis
Configuring PROFINET
CHAPTER 9 This chapter describes how to configure the PROFINET feature on the Cisco IE 3000 switch. Understanding PROFINET, page 9-1, page 9-4 Displaying the PROFINET Configuration, page 9-5 Troubleshooting
CP 342-5. Page 1342 Mar 2008 Siemens ITS
CP 342-5 Function The CP 342-5 provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61158/61784, master or slave) PG/OP communication S7 communication
Development of a Gateway to PROFIBUS for Remote Diagnostics
Development of a Gateway to PROFIBUS for Remote Diagnostics Hassan Kaghazchi, Donal Heffernan Automation Research Centre, University of Limerick, Ireland Abstract With the increased use of fielbuses in
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL
TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...
An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.
TECHNICAL DATASHEET #TDAX06070X Triaxial Inclinometer with Gyro ±180⁰ Pitch/Roll Angle Pitch Angle Rate Acceleration SAE J1939, Analog Output or RS-232 Options 2 M12 Connectors, IP67 with Electronic Assistant
Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface
Release date: 06-0- 09: Date of issue: 06-0- 009_eng.xml Model Number Single head system Features Parameterization interface for the application-specific adjustment of the sensor setting via the service
1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3
Contents Moxa Technical Support Team [email protected] 1 Application Description... 3 1.1 Objective... 3 1.2 Goals... 3 2 System Topology... 3 3 Hardware and Software Requirements... 4 4 Configuration...
The CP 342-5 provides access to different communication services of the PROFIBUS bus system:
SIPLUS CP 342-5 Function The CP 342-5 provides access to different communication services of the PROFIBUS bus system: PROFIBUS DP (according to IEC 61158/61784, master or slave) PG/OP communication S7
Combi switchbox with integrated 3/2 way pilot valve
H Combi switchbox with integrated 3/2 way pilot valve Construction The GEMÜ combi switchbox with integrated 3/2 way pilot valve for pneumatically operated quarter turn actuators has a micro-processor controlled
Industrial Bar Code Scanners
DS2100N & DS2400N Industrial Bar Code Scanners Enhanced Connectivity Ease of use Configuration SW Tool ACR-Lite APPLICATIONS Small conveyor sorting Picking systems Items and parts tracking Process control
SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.
SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,
154 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370 Main Office: (650) 588-9200-Outside Local
154 PHOENIX CONTACT PROFINET The future-oriented system solution PROFINET is the realtime Ethernet approach that can be used in all industrial motion control fields - from factory automation to process
MLC 9000+ TM Maximum Productivity and Versatility for Control without Compromise!
Data Sheet Maximum Productivity and Versatility for Control without Compromise! Basic Bus Communication Module DESCRIPTION The Basic Bus Communication Module (BCM) is part of the MLC 9000+ DIN rail mount
Modular I/O System Analog and Digital Interface Modules
OPERATING INSTRUCTIONS Modular I/O System Analog and Digital Interface Modules Installation Operation Maintenance Document Information Document ID Title: Operating Instructions Modular I/O System Part
Bus modules systron PM
E031006 000823 Bus modules systron PM Bus systems Many bus systems have been developed to accommodate PLCs and associated modules made by specific manufacturers. However, due to diversified application
Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System
Revised Sept--22-2009 Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System Description The sealed circular RJ45 connector system is designed for use in harsh environments. The connector
IBS IP KIS A. Data Sheet INTERBUS-S. Digital I/O Module
IBS IP KIS A Data Sheet Digital I/O Module Data Sheet Revision C Product Description The IBS KIS IP A module is a digital I/O module for the extended installation remote bus. Features - InterBuS-S protocol
PROFIBUS fault finding and health checking
PROFIBUS fault finding and health checking Andy Verwer Verwer Training & Consultancy Ltd PROFIBUS PROFIBUS is a very reliable and cost effective technology. It is common to find extensive installations
Research of PROFIBUS PA s integration in PROFINET IO
3rd International Conference on Material, Mechanical and Manufacturing Engineering (IC3ME 2015) Research of PROFIBUS PA s integration in PROFINET IO Zhijia Yang 1, a *, Zhongsheng Li 1,2,b, Feng Qiao 2
HydraPort 12 Module Connection Ports HPX-1200SL, Brushed Aluminum (FG560-03-SL) HPX-1200BL, Black Anodized (FG560-03-BL)
DATA SHEET HydraPort 12 Module Connection Ports HPX-1200SL, Brushed Aluminum (FG560-03-SL) HPX-1200BL, Black Anodized (FG560-03-BL) Overview With space for up to 12 modules, the HPX-1200 allows you to
Repeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
PROFIBUS/PROFINET System design
PROFIBUS/PROFINET System design Andy Verwer Technical Officer for PROFIBUS UK Verwer Training & Consultancy Ltd Gold distributor PROFIBUS PROFIBUS is by a large margin the most widely used fieldbus technology.
M8 / M12 CONNECTOR SYSTEM
M8 / M12 CONNECTOR SYSTEM EVERY CONNECTION COUNTS TE CONNECTIVITY S M8 / M12 Connector System for machine industrial automation and control applications provides a solution that safely and reliably ensures
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
PLUTO Safety-PLC. Manual Absolute Encoders
PLUTO Safety-PLC Manual Absolute Encoders English v6a 2TLC172006M0206_A Table of contents: 1 General... 3 1.1 Reaction time... 3 1.2 Safety parameters... 3 2 Electrical... 4 2.1 Separation with Gateway
Fieldbus slave modules with I/Os, DIO
140 Fieldbus slave modules with I/Os, DIO 1534CF00 1534CH00 1534PF00 1534PH00 1536CH00 1536CL10 1536PH00 1536PL00 Order number 1534CF00 1534CH00 1534PF00 1534PH00 Figure Type SM 153, CANopen slave, DIO
Application about Communication
Application about Communication Integration of ET200S PROFIBUS I/O in a Rockwell CompactLogix Controller Configuration Example Warranty, liability and support Note The application examples are not binding
INTMOD485-LH Protocol Converter
For Use with L-GAGE LH Series Sensors Features Converts an LH Network to the 485-RTU protocol Supports baud rates up to 230,400 baud Supports LH Networks with up to 32 sensors Model Protocol Conversion
Ordering Part Numbers:
TECHNICAL DATASHEET #TDAX021500 HYDRAULIC FAN CONTROLLER Application Platform 3 erature Sensors 4 Digital Command Interfaces 1 PWM Input and 1 Analog Input 1 Proportional or ON/OFF Current Output RS232
SNAP-SCM-PROFI Communication Module
SNAP-SCM-PROFI Communication Module Features Single isolated port with built-in DB-9 connector Baud rates to 1.5 MBaud Works with the SNAP PAC System Up to eight SNAP-SCM-PROFI modules per rack 30-month
Dupline Car Park System Type GP6220 330x 724-US 3-Colour Ultrasonic Sensor
Dupline Car Park System Type GP6220 330x 724-US 3-Colour Ultrasonic Sensor Product Description GP6220 330x 724-US is an ultrasonic sensor with a built-in 3 colour LED indicator and part of the Dupline
Industrial Bar Code Scanners
DS4800 Industrial Bar Code Scanners Enhanced Connectivity Ease of use Configuration SW Tool ACR4 technology Smart focus adjustment APPLICATIONS Automated warehousing Reading on pallets Picking systems
3 U CompactPCI Backplane with 4 Slots
3 U CompactPCI Backplane with 4 Slots State of the art design for a wide range of applications Image for visualization only General Description This standard backplane is member of the ERNI backplane familiy
SIMATIC NET. CP 243-2 AS-Interface Master B C. Preface Contents. Technical Description and Installation Instructions Interface to the User Program
Preface Contents SIMATIC NET CP 243-2 AS-Interface Master Manual Technical Description and Installation Instructions Interface to the User Program 2 in the S7-200 CPU Access to the Data of the AS-i Slaves
SIMATIC NET. AS-Interface - Introduction and Basics A B. Preface, Contents
Preface, Contents SIMATIC NET AS-Interface - Introduction and Basics Manual AS-Interface (AS-i) 1 AS- Interface Safety at Work (ASIsafe) 2 AS-i System Components 3 The Master Mode - Commands, Sequence,
User Manual. AS-Interface Programmer
AS-Interface Programmer Notice: RESTRICTIONS THE ZMD AS-INTERFACE PROGRAMMER HARDWARE AND ZMD AS-INTERFACE PROGRAMMER SOFTWARE IS DESIGNED FOR IC EVALUATION, LABORATORY SETUP AND MODULE DEVELOPMENT ONLY.
Part 1: User information SIMATIC ET 200B Distributed I/O Station Manual Part 2: Reference information Appendices EWA 4NEB 812 6089-02c Edition 04
Preface, Contents SIMATIC ET 200B Distributed I/O Station Manual Part 1: User information System Overview Technical Description Mechanical and Electrical 3 Installation Configuration and 4 Parameterization
How To Use A Light Bulb With A Power Supply (Power Supply)
DeviceNet Fieldbus Solutions Fieldbus Communication for DeviceNet Applications Lumberg Automation Provides Reliable DeviceNet Fieldbus Solutions for Industrial Automation Applications Worldwide. DeviceNet
DVPPF02-H2. PROFIBUS DP Slave Communication Module Application Manual
DVPPF02-H2 PROFIBUS DP Slave Communication Module Application Manual Warning Please read this instruction carefully before use and follow this instruction to operate the device in order to prevent damages
Programming Logic controllers
Programming Logic controllers Programmable Logic Controller (PLC) is a microprocessor based system that uses programmable memory to store instructions and implement functions such as logic, sequencing,
BNI EIP-950-000-Z009 IP67 Module, Unmanaged Switch
BNI EIP-950-000-Z009 IP67 Module, Unmanaged Switch Balluff Ethernet IP, BNI EIP-104-100-Z016 1 Notes to the User 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typgraphical Conventions 2 1.4 Symbols
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter
www.kem-kueppers.com [email protected] Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter Description The coriolis mass flow meters measure simultaneously mass
FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK
FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK Field busses are industrial control systems using Programmable Logic lers (PLC) to control and manage field devices found in industrial environments. The communication
Natural Gas Well Automation using Kingfisher RTU Products
Natural Gas Well Automation using Kingfisher RTU Products Introduction Semaphore s Kingfisher RTU products have been applied to well site installations throughout the world. The product family includes
NEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
Magnetic proximity switches
Magnetic proximity switches Magnetic proximity switches Overview Page 38 Functional principle and installation Page 39 Cylindrical designs Page 41 Rectangular designs Page 42 37 Kurzübersicht Magnetoresistive
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Industrial Bar Code Scanners
DX8200A Industrial Bar Code Scanners Configuration SW Tool ACR4 technology PackTrack ASTRA technology APPLICATIONS Postal/Courier parcel sorting and tracking Automated warehousing identification systems
Safety Relays ESM/ESM-F
Safety Relays ESM/ESM-F More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in
GE Power Controls FIELDBUS APPENDIX PROFIBUS DP. Doc. No.: ASTAT Plus PB_Appendix-v0
GE Power Controls = FIELDBUS APPENDIX PROFIBUS DP = Doc. No.: ASTAT Plus PB_Appendix-v0 Fieldbus Appendix: PROFIBUS DP 1 Fieldbus Introduction...... 2 1.1 Introduction to Profibus-DP... 2 1.2 Network Overview...
Color Mark Sensor with Red or Green LED E3S-VS
Color Mark Sensor with Red or Green LED Rugged IP67 Color Mark Sensor 1 ms response time Detects a wide variety of color marks PNP or NPN output ls Light-on/ Dark-on operation, wire selectable Vertical
Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141
ATEX category II 1 G, Ex zone 0 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, height 6mm Plastic, PA12 Magnetic-inductive sensor DC 2-wire, nom. 8.2 VDC Output acc. to DIN EN 60947-5-6