Harmonics 101 What are they, why do I care, and how do I solve them?

Similar documents
The Facts About Harmonics and Power Factor. Power Quality: Harmonics & Power Factor Correction

Power System Harmonics

Product Data Bulletin

POWER SYSTEM HARMONICS. A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS

Power Quality Issues, Impacts, and Mitigation for Industrial Customers

Interpreting IEEE Std 519 and Meeting its Harmonic Limits in VFD Applications

Introduction. Harmonics and IEEE 519 Page 1 of 19

Harmonic Distortion and Variable Frequency Drives

Triplen Harmonics Mitigation 3 Phase Four-Wire Electrical Distribution System Using Wye- Zig-Zag Transformers

Line Reactors and AC Drives

Harmonics in your electrical system

VARIABLE FREQUENCY DRIVE OPERATION AND APPLICATION OF VARIABLE FREQUENCY DRIVE (VFD) TECHNOLOGY

Session 10: General Overview of Interconnection Standards & Grid Codes for High Penetration PV October 21, 2015 Santiago, Chile

Fundamentals of Power Electronics. Robert W. Erickson University of Colorado, Boulder

UNDERSTANDING POWER FACTOR AND INPUT CURRENT HARMONICS IN SWITCHED MODE POWER SUPPLIES

HOW HARMONICS HAVE CONTRIBUTED TO MANY POWER FACTOR MISCONCEPTIONS

Design a Phase Interleaving PFC Buck Boost Converter to Improve the Power Factor

HARMONIC DISTORTION IN THE ELECTRIC SUPPLY SYSTEM

Power Quality Standards for Electric Service

Power System Harmonic Fundamental Considerations: Tips and Tools for Reducing Harmonic Distortion in Electronic Drive Applications

The Different Types of UPS Systems

Analysis of AC-DC Converter Based on Power Factor and THD

Power Quality. Uninterruptible Power Supply

Survey of Harmonics Measurements in Electrical Distribution System of a Technical Institution

SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE WELDERS

Survey of Harmonics Measurements in Electrical Distribution Systems

Neutral Currents in Three Phase Wye Systems

Mitigating data center harmonics

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

The Different Types of UPS Systems

Practical Overview of Mine Power System Harmonics

DESIGNING MODERN ELECTRICAL SYSTEMS WITH TRANSFORMERS THAT INHERENTLY REDUCE HARMONIC DISTORTION IN A PC-RICH ENVIRONMENT

Specifying a Variable Frequency Drive s

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

The Different Types of UPS Systems

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

A COMPARISON OF TYPICAL UNINTERRUPTIBLE POWER SUPPLY (UPS) DESIGNS IN TODAY S MARKETS

Power Electronics. Prof. K. Gopakumar. Centre for Electronics Design and Technology. Indian Institute of Science, Bangalore.

Technical Comparison of On-line vs. Line-interactive UPS designs

Advantages of 6-Pulse VFD with Lineator AUHF vs Active Front End (AFE) Drives

Power Quality & Custom Power

Electromagnetic Compatibility (EMC) Low-Frequency Standards. Standards on Low-Frequency Emission: IEC

VOLTAGE REGULATOR AND PARALLEL OPERATION

CONTROL OF HARMONICS IN ELECTRICAL POWER SYSTEMS

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Data center power dynamics within the settings of regional power grid

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

System Standard For the Installation of New Loads

21 st Century Facilities

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Relationship between large subject matter areas

How To Improve Power Quality

Power Meter Series 700

AC/DC Power Supply Reference Design. Advanced SMPS Applications using the dspic DSC SMPS Family

Supply Standards: Electricity Supply Standard July JULY 2011 ISSUE 6 UNCLASSIFIED UNCONTROLLED COPY IF PRINTED

Power surges can also be generated by equipment in your facility such as:

Transfer Equipment Controls

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

The design and performance of Static Var Compensators for particle accelerators

PHASE CONVERSION TECHNOLOGY OVERVIEW

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications

A Low Cost Power Quality and Energy Savings Laboratory for Undergraduate Education and Research

Survey of Harmonics Measurements in Electrical Distribution Systems

COMPARISON OF THE FACTS EQUIPMENT OPERATION IN TRANSMISSION AND DISTRIBUTION SYSTEMS

Anais Volume 1 COBEP99 UFPR UFSM

Improvements of Reliability of Micro Hydro Power Plants in Sri Lanka

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

VICOR WHITE PAPER. The Sine Amplitude Converter Topology Provides Superior Efficiency and Power Density in Intermediate Bus Architecture Applications

CERN Accelerator School. Electrical Network and Power Converters. Hans Ulrich Boksberger Paul Scherrer Institute 5232 Villigen PSI Switzerland

A MULTILEVEL INVERTER FOR SYNCHRONIZING THE GRID WITH RENEWABLE ENERGY SOURCES BY IMPLEMENTING BATTERY CUM DC-DC CONERTER

98% Efficient Single-Stage AC/DC Converter Topologies

Harmonic components: electrical network polluters. LV and MV networks are becoming increasingly polluted by current and voltage harmonics. Harmonics a

APPLICATION OF IEEE STD HARMONIC LIMITS

APPLICATION OF IEEE STD HARMONIC LIMITS

FREQUENCY CONTROLLED AC MOTOR DRIVE

Current and Temperature Ratings

Understanding Power Factor, Crest Factor, and Surge Factor. White Paper #17

Power Supplies. 1.0 Power Supply Basics. Module

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

Selecting a UPS Topology for your Data Center. by Dr. Daniel Becker, Ph.D., Methode Active Energy Solutions

UPS Applications and VRLA Battery Sizing

PM734F - Technical Data Sheet Winding 28

Paralleling Power Sources Which Share a Common Neutral

Performance of 3-Phase 4-Wire Solid State Transformer under Imbalanced Loads

CYCLOCONVERTERS. Fig.1 Block diagram of a cycloconverter

The Seven Types of Power Problems

Asia Pacific Regional Power Quality Seminar March 2005, Marriot Putrajaya, Malaysia. Voltage Source Converter based Power Quality Solutions

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Theoretical review. Contents

EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

SBS & UPS Tutorial. OFF-LINE (SBS), the lowest grade. LINE-INTERACTIVE (SBS), the middle grade. ON-LINE (UPS), the highest grade

Application Guide. Power Factor Correction (PFC) Basics

Power Quality. Voltage Sag Ride-through Mitigation in Sequence by Increasing Cost

UCI274C - Technical Data Sheet

Principles of Adjustable Frequency Drives

Transcription:

ABB Harmonics 101 What are they, why do I care, and how do I solve them? ABB Inc. January 15, 2015 Slide 1

Drive Harmonic Solutions Speaker name: Speaker title: Company name: Location: Jeff Fell Sr. Application Engineer ABB, Inc. (Low Voltage Drives) New Berlin, WI ABB Inc. January 15, 2015 Slide 2

Table of Contents Harmonics What are they? What are the problems? How much is too much? What can I do? ABB LV Drives Property of ABB LV Drives, Do Not Copy Slide 3

What kinds of Power Quality Issues are there? Sag Dip Brown-out Under-voltage Droop Surge Swell Over-voltage Harmonics Sub-harmonics Interruption Outage Black-out Flicker Single-phasing Transient Spike Impulse Notch Glitch 4

What kinds of Power Quality Issues are there? Sag Dip Not Enough Interruption Outage Nothing s There Brown-out Black-out Under-voltage Flicker Droop Surge Swell Too Much Single-phasing Transient Spike Watch Out! Over-voltage Impulse Harmonics Sub-harmonics Odd Stuff Notch Glitch Something weird? 5

What are Harmonics? 0.0 0 10.0 20.0 30.0 A sinusoidal waveform has no harmonics 40.0 Rfund.V = 0.0 100.0 50 0 0 0.0-50 0.0-100 This is an example of a linear load 0.0-150 0 10.0 20.0 30.0 40.0

What are Harmonics? 0.0 0 10.0 20.0 30.0 A non-sinusoidal waveform contains harmonics 40.0 Rtotal.V =. 0.0 100.0 50 0 0 0.0-50 0.0-100 This is considered a non-linear load 0.0-150 0 10.0 20.0 30.0 40.0

Harmonics What? Basic concept Harmonics are associated with non-linear loads which draw non-sinusoidal currents from a essentially sinusoidal voltage source (i.e. load current doesn t look like applied voltage): Non-incandescent lighting Computers Uninterruptible power supplies Telecommunications equipment Copy machines Battery chargers Any device with a solid state AC to DC power converter Adjustable speed drives ABB LV Drives Property of ABB LV Drives, Do Not Copy Slide 8

Analysis Frequency, Amplitude, Phase Angle Harmonics are simply integer multiples of the fundamental frequency for example, if 60Hz is the fundamental (sometimes referred to as the 1st harmonic), then the 2nd harmonic is 120Hz, the 3rd harmonic is 180Hz, etc. Any non-sinusoidal waveform can be created by the addition of harmonics at various amplitudes and phase angles % Amplitude 9 Harmonic Number

What Is I(THD)? I(THD) = Iharm / Ifund So, Iharm = I(THD) * Ifund I(THD) is a ratio between two numbers, it does not stand alone! We can decrease I(THD) by either decreasing Iharm or increasing Ifund 10

Root Cause of Problems with Other Equipment Current Harmonics create Voltage Distortion

1500kVA, 75hp Ithd = 37% Vthd = 0.9% 12

75kVA, 75hp Ithd = 29% Vthd = 9.3% 13

What other problems do they cause? Increased Utility current requirement Inability to expand or utilize equipment Larger wire size needed = increased installation costs Component overheating Distribution transformers, generators & wires Reduced Utility power factor Increase in utility costs Equipment malfunction Due to multiple or loss of zero crossing Due to voltage distortion such as flat topping Excitation of Power System Resonance's creating overvoltage s If PFCC in system 14

15 How much is too much?

IEEE Std 519-1992 16

What are the IEEE 519-1992 standards? 17 Harmonic Voltage Limits Low-Voltage Systems Table 10.2 Application Maximum THD (%) Special Applications - hospitals and airports 3.0% General System 5.0% Dedicated System - exclusively converter load 10.0% Current distortion Limits for General Distribution Systems (120V through 69,000V) Maximum Harmonic Current Distortion in Percent of Iload Isc/Iload <11 11<=h<17 17<=h<23 23<=h<35 35<=h TDD (%) <20 4.0 2.0 1.5 0.6 0.3 5.0 20<50 7.0 3.5 2.5 1.0 0.5 8.0 50<100 10.0 4.5 4.0 1.5 0.7 12.0 100<1000 12.0 5.5 5.0 2.0 1.0 15.0 >1000 15.0 7.0 6.0 2.5 1.4 20.0 Even harmonics are limited to 25% of the odd harmonic limits above Isc=maximum short circuit current at PCC Iload=maximum demand load current (fundamental frequency component) at PCC Rsc = Isc / Iload Table 10.3

How does motor load affect I(THD)? % of Full Load Fund. Curren 100 90 80 70 60 50 40 30 20 10 0 6-Pulse Buffered Drive Currents Iharm Ifund I(THD) 0 20 40 60 80 100 % Load I(TDD) 18 NOTES: I(THD) = Iharm / Ifund I(THD) increases as load decreases Ifund decreases as load decreases Iharm decreases as load decreases (drive is at full speed)

Vthd vs Load, What is Worst Case? 50 45 40 35 30 I(TDD) 25 20 15 Ithd, % Iharm, A Vthd, % 10 5 0 0 10 20 30 40 50 60 70 80 90 100 % Load Max Vthd 100hp drive on 250kVA xfmr, 6% 19

The Goal of IEEE 519 Thou Shalt Not Mess Up Thy Neighbor s Line Voltage 20

Where to Apply the PCC? Utility Utility Substation Current limits in IEEE 519-1992 were meant to be applied at the Point of Common Coupling (PCC) between the utility system and multiple customers. IEEE P519A Section 3.4 PCC 1 PCC 2 PCC 3 Customer 1 Hospital Customer 2 Customer 3

Why does a drive produce harmonics? Converting AC to DC 6-Pulse Drive Fixed V Fixed f Adjust V Adjust f

Why does a drive produce harmonics? Converting AC to DC 2DGraphSel1 800.00 700.00 Vab Vac Vbus 600.00 500.00 400.00 300.00 200.00 Van Ia L1.I [A] VMan... VMab... C1.V [V] VMac... 100.00 0-100.00 182.00m 184.00m 186.00m 188.00m 190.00m 193.50m 23

Harmonics What can I do? Possible solutions Reactors or Chokes AC Line Reactor DC Link Choke Swinging Choke Drive Isolation Transformer Passive Filters Passive or Trap Harmonic Filter High Pulse Count Rectification Harmonic Cancelation 12, 18, 24, 36 Pulse or Poor Man s 12-pulse Active Methods Drive Active Front End (AFE, ULH or Regen) Stand Alone (Active Harmonic Filter) ABB LV Drives Property of ABB LV Drives, Do Not Copy Slide 24

Harmonics What can I do? Reactors (chokes) Simplest and least expensive harmonic reduction technique May be included in base drive package Often meet harmonic needs provided drive load is a small portion of total connected load May be implemented with AC line reactors or with DC link reactors AC line reactors provide better input protection DC link reactors provide better output voltage regulation Both types provide similar harmonic benefits Swinging choke design provides enhanced light load harmonic performance ABB LV Drives Property of ABB LV Drives, Do Not Copy Slide 25

Harmonics What can I do? AC Line Reactor or DC Link Choke AC Line Reactor DC Link Choke Reactor M Different design techniques Equal harmonic reduction for same normalized % reactance Typical full load THD (current) at drive input terminals reduced to 28% to 46% Ithd M Existence not position is what is most important ABB LV Drives Property of ABB LV Drives, Do Not Copy Slide 26

Harmonics What can I do? Reactor effectiveness THD (Current) vs. % Reactor 120 100 Current harmonic content (THD) at drive input terminals as a function of normalized % reactance and network short circuit ratio %THD (Current) 80 60 40 20 0 0 1 2 3 4 5 6 7 8 9 % Reactor Rsc = 20 Rsc = 60 Rsc = 200 ABB LV Drives Property of ABB LV Drives, Do Not Copy Slide 27

DC Link Choke in the ACS550 New Swinging DC Link Choke USF Patent Pending Designed to reduce harmonics at full and partial loads Perfect for Variable Torque Centrifugal Loads Equivalent to 5% line reactor More inductance per volume/weight

Harmonics What can I do? Swinging choke vs. fixed choke Current Distortion vs % Speed for Variable Torque Load 45 40 %TDD (Current) 35 30 25 20 15 10 5 5% Swinging Choke 3% Fixed Choke Swing Choke Benefit Vs. 5% Fixed Choke 0 0% 20% 40% 60% 80% 100% 120% % Speed ABB LV Drives Property of ABB LV Drives, Do Not Copy Slide 29

Line Reactor or Isolation Transformer Benefits Reduces harmonic currents Reduces Drive input currents Suppresses voltage transients Compensates for unbalanced line voltage Highly reliable (passive solution) Transformer only Electrically isolates Drive from distribution system Provides neutral connection for delta system Provides voltage matching Reduces transfer of common & differential mode impulses Line Reactor Disadvantages Voltage Drop at full power Adds heat to room Transformer Expensive - 250% more than reactor solution Size - Separate Floor Mount 400% or more larger than reactor solution Consumes power - draws magnetizing current even with Drive off Adds heat to room

Line Current Harmonic Mitigation Methods 6-Pulse Filters Passive or Trap Harmonic Filter Passive Notch Filter May feed multiple drives Improves power factor (may go leading) Typical full load THD (current) at filter input terminals (line side) 10% 14% Performance reduced by line imbalance

High Pulse Count Rectification Circuits and characteristics Performance 6-pulse Rectifier 12-pulse Rectifier 18-pulse Rectifier AFE, ULH or Regen Drive DC/AC DC/AC DC/AC AC/DC DC/AC Transformer not required; Simple cabling Transformer required; More cabling, more space, more weight Transformer required; Complex cabling, increased space and weight over a 12 pulse Transformer Not required; Simple cabling, space and weight same as a 6 pulse Current distorted I THD 35% to 46% (3% reactor) Current slightly distorted I THD 8% to 12% Current wave form good I THD 4% to 6% Current wave form good I THD 4% to 6% AFE= Active Front End ABB LV Drives Property of ABB LV Drives, Do Not Copy Slide 32

Harmonics What can I do? Active front end - impressive performance Active supply Meets IEEE 519 Near sinusoidal line current Total current distortion meets IEEE TDD (rated load) Total voltage distortion less than 5.0% 5 4 3 2 1 0 % THD (current) and harmonic components 1 7 13 19 25 31 37 43 49 55 61 67 73 79 85 91 97 harmonic number Out of the box Unity Power Factor! %THD (Voltage) = f(r SC ) 5 4 3 2 1 0 10 20 30 40 50 60 70 80 90 100 R SC ABB LV Drives Property of ABB LV Drives, Do Not Copy Slide 33

Harmonics What can I do? Active front end drives, what do they look like? Wall-mounted low harmonic drive ACS800-U11/U31 10 125 HP Cabinet-built low harmonic drive ACS800-17/37 75-2800 HP ABB LV Drives Property of ABB LV Drives, Do Not Copy Slide 34

Harmonics What can I do? Active front end drives, what do they look like? MV Drive, ACS 2000 4kV 300-3000 HP ABB LV Drives Property of ABB LV Drives, Do Not Copy Slide 35

Active Front End Benefits Most effective solution Unity power factor Standard Drive Product No dedicated transformer required Lower transformer losses compensates overall efficiency Harmonic performance robust against supply input imbalances Reduces size of back-up generator Only solution that can boost the DC Bus voltage (up to 15%) when motor requires it Disadvantages More costly than reactor and passive filter solutions Size - larger foot print - more equipment to package Active solution, therefore dependent on reliability of electronics

Harmonics What can I do? Harmonic reduction summary Typical Results Technique Current THD No mitigation 70-120% 3% Line Reactors or DC Link Choke 40-50% 5% Line Reactors or DC Link Choke 25-40% 12-Pulse Rectifier 10-15% Passive Harmonic Filter 8-12% 18-Pulse Rectifier 4-6% Active Front End or Active Harmonic Filter 3-5% Performance Complexity Cost + Remember - Take measurements at MAXIMUM load. THD = harmonics / fundamental ABB LV Drives Property of ABB LV Drives, Do Not Copy Slide 37

ABB Group January 15, 2015 Slide 38