Modular UPS systems Uninterruptible power supply systems The modular approach

Similar documents
Standardization and modularity as the foundation of data center UPS infrastructure

Power protection for data centers

Product catalog ABB UPS products and solutions Power protection for critical infrastructures

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

An Uninterruptible Power Supply Topology to Manage the Arrival of Big Data Kenny Green

Phase Modular Finally the benefits of Modular ups are for all

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers

GAMATRONIC ELECTRONIC INDUSTRIES LTD.

Data centre experts. Advanced power protection for data centres

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

PowerGem Pro Uninterruptible Power Supply

4.0 UPS dedicated to ICT for unmatched energy savings

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Maximizing UPS Availability

IT White Paper. N + 1 Become Too Many + 1?

Opportunity of Energy Saving in electrical path is lesser as compared to other areas

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

The Different Types of UPS Systems

Galaxy VM. Three-phase power protection. schneider-electric.com

Power to the adaptable data center

Designed for uptime. Defining data center availability via a tier classification system

Conceptpower DPA kva. True modular UPS system for critical applications. Modular Three-phase UPS system

PX100 MBP with Configurable Distribution

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Data Center Trend: Distributed Power in the White Space

How Microsoft Designs its Cloud-Scale Servers

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理. Schneider Electric - Division - Name Date

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

Alternative data center power

Evaluating the Opportunity for DC Power in the Data Center

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

Product brochure Eaton 93PS UPS 8-40 kw. More advanced. power. protection

LAP ENERGIA PARA DATACENTERS

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Eaton 93PM UPS Where aesthetics meet intelligence.

Smart-UPS 3 Phase And MGE Galaxy 3500

Wireless Networks and Power Quality

SSPI-APPN OTES: PARALLEL C ONNECTIONS

Liebert NXC from 10 to 200 kva

The Different Types of UPS Systems

Tough Decision: On-Line or Line-Interactive UPS?

Radware ADC-VX Solution. The Agility of Virtual; The Predictability of Physical

Product catalog. Cyberex data center products Overview catalog

Distributed versus centralized power backup strategies

Electrical Systems. <Presenter>

UPS system for emergency lighting and smoke extraction

The Different Types of UPS Systems

Overview brochure. Power management solutions for network closets, server rooms and data center environments

Advantages and Efficient Use of Programmable Sockets. By Miguel Rascon AC Power Senior Product Manager

Increased power protection with parallel UPS configurations

UPS Topologies & Architectures. Don Lemmon Tubbesing Solutions (214) don@tubbesing.com

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

Considering the effects of UPS operation with leading power factor loads

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

ABB PSPS Erich Steinmann; Generator control-2013

Microsoft s Open CloudServer

Is an energy-wasting data center draining your bottom line?

Qualitative Analysis of Power Distribution Configurations for Data Centers

High-density modular data center making cloud easier. Frank Zheng Huawei

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

TLE Series. Product Description kva / 400Vac / S1 KEY BENEFIT APPLICATIONS FEATURES

Essential NCPI Management Requirements for Next Generation Data Centers

415V DISTRIBUTION FOR GREEN DATA CENTERS

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

415V DISTRIBUTION FOR GREEN DATA CENTERS

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA

Power Distribution Considerations for Data Center Racks

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

Case Study Nottingham Trent University

Power Quality. Uninterruptible Power Supply

T:

Juniper Networks QFabric: Scaling for the Modern Data Center

Relay2 Enterprise Cloud Controller Datasheet

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

How To Power A Bladecenter H Servers

Eaton 93PM UPS Efficient. Scalable. Innovative.

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

DISTRIBUTED REDUNDANCY:

Analysis of the Brazilian Data Center Power Supplies Market

A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture

Radware ADC-VX Solution. The Agility of Virtual; The Predictability of Physical

IT White Paper IP TELEPHONY AND RELIABILITY: PROTECTING MISSION-CRITICAL PHONE SYSTEMS FROM POWER THREATS

Eaton 93PM UPS Efficient. Scalable. Innovative.

Diesel Rotary UPS reliability and process availability

Common mistakes in datacentre planning

PAYGO for Data Center -- Modular Infrastructure

Transcription:

Modular systems Uninterruptible power supply systems The modular approach

The modular approach Why a modular increases availability and lowers total cost of ownership The effect of a power failure in a data center can be disastrous. So great care is taken to make sure that the very best back-up power scheme is in place. A reliable and efficient uninterruptible power supply () is a mainstay of such as scheme. Once the is installed, however, it becomes a focus of reliability for what use is it if it fails just when it is needed? For this reason, the most critical loads must be protected by the very best design. ABB, as one of the leading suppliers of, has invested much effort in developing and refining a design that optimizes availability and total cost of ownership. ABB s unique design is based on the concept of true modularity. Modularity In ABB s range of modular s, each module has all the hardware and software needed for autonomous operation rectifier, inverter, battery converter, static bypass switch, back-feed protection, control logic, display, and mimic diagram for monitoring and control. With all the critical components distributed between individual units, potential single points of failure are eliminated. If redundancy is provided for, there are more modules than are needed to supply the critical load. In a redundant system, all modules are active and share the load equally. Should one module fail, the remaining modules take over the load smoothly. The system is fault tolerant and there are no single points of failure. ABB calls this modular approach decentralized parallel architecture (DPA). DPA not only provides the best availability, but also the best serviceability, scalability and flexibility. Taken together, these features all deliver a low total cost of ownership (TCO). Modular with common system components Modular with no common system components Rectifier input Bypass input Main unit Control logic Display Rectifier input Bypass input Power module module Control logic Display Power module module Control logic Display Power module Output to the critical load module Control logic Display Output to the critical load In centralized systems, failure of one point can bring down the entire system; in DPA, each module has all the hardware and software it needs for autonomous operation there are no shared critical elements and therefore no single points of failure. ABB modular systems The modular approach 2

Availability and how to increase it For all applications, availability is the most crucial parameter. It is a measure of how much time per year a system is up and available. power availability is measured by MTBF and MTTR (see figure to the right). From the equation, it can be seen that the best ways to increase power availability are to increase the MTBF and decrease the MTTR of the power protection system. The nature of the modular design lends itself very well to achieving this objective. How to increase availability: Add redundancy Minimize chance for human error Select high quality, reliable equipment Minimize downtime Standardize service concept Reliability Measure of ability of a system to run without failures Mean time between failures (MTBF) Serviceability The ease and speed of maintenance and service Mean time to repair/recover (MTTR) Availability A measure of time a system is operational uptime Availability = MTBF MTBF + MTTR The best ways to maximize power availability are to increase MTBF and to decrease MTTR of the power protection system. ABB modular systems The modular approach 3

How a modular increases availability Add redundancy The surest way to increase availability of power is to add redundancy to the system and to minimize its maintenance and repair time. One major advantage of modularity is the ease with which redundancy can be accommodated. Usually, adding redundancy merely involves configuring one module more than is necessary to cover the basic load. This is then switched in automatically when required. Mimize chance for human error ABB s modules can be online-swapped, ie, removed or inserted, without risk to the critical load and without the need to power down or transfer to the mains. This procedure is simple and quick to perform and introduces no risk for system operation. Each module can be individually switched off before removing it from the system. This makes the service safe for the technician and ensures absolutely no disturbance to the system. As the same modular can be used across different applications and load segments, the service technicians do not need to be educated on several different platforms, but can apply the same practices and procedures on all equipment. Select high-quality, reliable equipment In ABB DPA s, the incoming AC is first converted to DC. The output AC is then synthesized from this DC giving a clean sinusoid. These two conversion steps give the term double conversion and isolate the output voltage waveform from any disturbances on the input AC side. Minimize downtime Because the modules in a DPA are independent, they can be online-swapped without risk to the critical load and without the need to power down or transfer to raw mains supply. So engineers can work on the without interrupting operations. Swap-out time is only 15 20 minutes and is very safe and you never have to switch off your load. Online-swappable modules directly address availability requirements, significantly reduce MTTR, reduce inventory levels of specialist spare parts and simplify system upgrades. Standardize service concept DPA modules are standardized. This keeps costs low: A straightforward, standardized modular concept simplifies and speeds every step of the deployment process from planning, through installation and commissioning to final use. High-quality standardized products significantly reduce intervention time during maintenance or in the event of failure components can be changed quickly and easily and service is simplified. The better quality that results from the mass production and testing of standardized modules has a direct positive impact on reliability and, thus availability: modular systems with standardized connections can be pre-wired and fieldconfigured at the factory, allowing for more thorough testing, and standardized connections and front access reduce the risk of bad connections in the field. With over 20 years experience in modular, ABB s Swiss-made DPA delivers unrivaled availability and the serviceability, scalability, flexibility and low energy usage made possible by the modular DPA approach deliver a very attractive TCO. There are no better architectures available to those users whose critical electrical loads represent a valuable commercial asset that must be kept powered at all costs. ABB modular systems Increasing availability 4

Total Cost of Ownership (TCO) TCO is the sum of capital expenditure (CapEx) and operating expenditure (OpEx). The CapEx of a comprises the itself and battery bank, the surrounding infrastructure and the installation and commissioning costs. Energy consumption and maintenance are the two big contributors to OpEx. How to minimize Total Cost of Ownership: Optimize your investments Optimize your battery capacity Save valuable floor space Reduce installation and maintenance costs Save energy costs Optimize your investments As power requirements change if a data center is expanded, say modularity makes it really easy to add modules and increase the power capabilities. You don t have to overspecify the initial configuration to cater for future expansion, you just add modules when needed. This means that you only cable, power and cool what you need. Power consumption is a topic of great concern for most operators and the energy savings made by the modular approach over the service life of the are substantial. Optimize your battery capacity Run-time and battery sizing can be exactly fitted to what is required. A separate battery allows the system to be upgraded and autonomy preserved, while not compromising availability. Full redundancy is only achieved with a redundant battery. If a common battery may be required, ABB s modular allow flexible blocks per string. The capacity can be changed with changing load, reducing the need to oversize. Below: Example of a changing (increasing) load up to 120 kw in 4 years. kw 180 160 140 120 100 80 60 Oversized capacity = saving potential Standalone solution: 1 60 kw (+60 kw) until year 1 2 60 kw (+60 kw) years 1 4 Oversized capacity Modular solution: 20 kw modules can be added or removed at any time. Typical 4-year load curve of a medium-sized data center. 40 Year 1 Year 2 Year 3 Year 4 ABB modular systems Total Cost of Ownership 5

Save valuable floor space Modularity lends itself well to keeping footprint small, too ideal where real estate is limited and expensive. A modular rack has a small footprint and when extra modules are added, no extra floor space is taken up. 0.7 Total footprint 3.2 m 2 Clearance 0.55 0.7 1m Total footprint 1.11 m 2 Clearance 0.16 0.4 Clearance 1.8 Reduce installation and maintenance costs The modular approach makes installation and commissioning easy. Standardized modules reduce inventory levels of specialist spare parts and simplify system upgrades. This approach pays off too when it comes to serviceability and availability as service personnel do not need special skills and human error is reduced. Spares can be held on-site or at a nearby service center. Not only does this improve availability but it also reduces cost as service engineers spend less time on-site, and any risks of data or production loss are minimized. The only elements common to all modules are contained in the mechanical frame that accommodates the modules I/O connection, customer interface signaling, maintenance bypass and, in some models, a system display. These elements are standardized in order to minimize maintenance costs. Traditional 2 180 kw (2N) Modular up to 180 kw (N+1) Modularity minimizes space requirements and maximizes predictability of future space requirements. In the example shown, 2 m 2 is saved. Module connectors ABB design simplifies service: The ABB design for module connectors makes swapping modules very easy and safe. Double conversion efficiency Conceptpower DPA 500 Efficiency (%) 100% 98% 96% 94% 92% 95.8% 96.1% 96.0% 95.6% 90% 0% 25% 50% 75% 100% Load (% of nominal) Save energy costs The modularity and scalability described have a major positive impact on achieving a low cost of ownership, but costs are held down too by designs that have best-in-class energy efficiency. ABB s Conceptpower DPA 500, for example, operates with an efficiency of up to 96 percent. Its efficiency curve is very flat so there are significant savings in every working regime. Further, cooling costs can be substantial and, because less power is consumed, high-efficiency modular s require less cooling effort, creating further savings. ABB modular systems Total Cost of Ownership 6

Modular applications The modular concept permits a range of different power protection solutions for all types of IT applications. The function can be located centrally or located beside each row of servers ( end of rack row ). A centralized power protection concept is appropriate, in most cases, for large data centers. A distributed power protection concept may be applicable in small data centers or large data centers with decentralized power protection demands. Distributed power protection solutions Servers with single power supply Servers with dual power supply Busbar A Busbar B 3 modules (20 kw) Server racks +4 modules 2 modules (40 kw) Server racks +4 modules 2 modules (40 kw) Busbar A Busbar B 7 modules (20 kw) Server racks In this distributed power protection concept, the power demand grows from 40 kw (N+1) to 120 kw (N+1). The can be easily adapted to meet the power demands of the growing infrastructure by adding four 20 kw modules. 4 modules (40 kw) Server racks 4 modules (40 kw) The power demand in the sample configuration increases from 40 kw (N+1) to 120 kw (N+1). The is perfectly capable of adapting to this increase in power demand. Centralized power protection solutions System A 4 300 kw G G System B 4 300 kw G G extendable extendable PDUs A Load PDUs B The sample reference scenario, 1,200 kw Tier 4, illustrates one example of how ABB s modular can be used to create a high performance infrastructure. The system flexibility allows power capacity to be upgraded to 3 MW. Critical applications are best served by using modular technology with an N+1 configuration. ABB modular systems Modular applications 7

Modular product overview Modularity the simple answer ABB s decentralized parallel architecture provides full redundancy and fault tolerance in a way that is unique amongst vendors. modules can be swapped online, which means fast and easy service and no downtime at all. DPA and modularity result in many knock-on advantages that guarantee that ABB s modular has the lowest TCO around while providing the operator with a flexible, reliable, agile and environmentally attractive infrastructure. The overwhelming benefits of modular s speak for themselves. ABB Newave were pioneers in technology and see standardization and modularity as key elements in design for the foreseeable future. DPA cale RI DPA cale ST Conceptpower DPA Conceptpower DPA 500 GENERAL DATA frame rated power 10 / 20 / 40 / 80 kw 60 / 80 / 120 / 200 kw 50 / 150 / 250 kva 500 kw module rated 10 / 20 kw 10 / 20 kw 30 / 40 / 50 kva 100 kw power output rated PF 1.0 1.0 0.8 1.0 Max. no of parallel 1 subrack 1 frame up to 6 frames up to 6 frames frames Max no of parallel 4 modules 10 modules 30 modules 30 modules modules across frames Max system power 80 kw 200 kw 1500 kva 3000 kw Wiring 3ph + N + PE 3ph + N + PE 3ph + N + PE 3ph + N + PE type Modular (DPA) Modular (DPA) Modular (DPA) Modular (DPA) Topology True online double conversion True online double conversion True online double conversion True online double conversion EFFICIENCY Double conversion Up to 96% Up to 96% Up to 96% Up to 96% Eco-mode 98% 98% 99% 99% COMMUNICATIONS User Interface Module level LCD + mimic diagram Remote system display optional Module level LCD + mimic diagram Remote system display optional Module level LCD + mimic diagram Module level LCD + mimic diagram System graphical touch screen (one per system) Communication ports USB, RS-232, SNMP slot, potential-free contacts USB, RS-232, SNMP slot, potential-free contacts USB, RS-232, SNMP slot, potential-free contacts USB, RS-232, SNMP slot, potential-free contacts Software monitoring and shutdown software available as option ABB modular systems Modular product overview 8

Contact us www.abb.com/ups Copyright ABB. All rights reserved. Specifications subject to change without notice. 4NWP100606R0001