A Guide to High Resistance Grounding

Similar documents
Ground Fault Protection on Ungrounded and High Resistance Grounded Systems

ASK THE EXPERTS. Resistance Grounding Q&A. with industry experts

The following table shows approximate percentage wise the

100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd

Fortune Oregon Data Center Increases Reliability with a High Resistance Grounding System

4.5 Transformer Connections

Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

GROUNDING AND GROUND FAULT PROTECTION OF MULTIPLE GENERATOR INSTALLATIONS ON MEDIUM-VOLTAGE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS

Line to Ground Voltage Monitoring on Ungrounded and Impedance Grounded Power Systems

SPECIAL TOPICS ON GROUND FAULT PROTECTION AND PROTECTION COORDINATION IN INDUSTRIAL AND COMMERCIAL POWER SYSTEMS

Shunt Capacitor Bank Fundamentals and Protection

Paralleling Power Sources Which Share a Common Neutral

Three phase circuits

Chapter 24. Three-Phase Voltage Generation

Figure. 1 - Split Phase 240/120V circuit (180 phase shift)

Fault Characteristics in Electrical Equipment

Equipment: Power Supply, DAI, Variable resistance (8311), Variable inductance (8321)

Management Systems 10 Electrical Safety Audit 14 PPE 20 Arc Mitigation 22 Hazard Assessment 26

FIT TIER 2 Application

System Grounding and Ground-Fault Protection Methods for UPS-Supplied Power Systems

Earth Fault Detection Basics in Theory

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Short Circuit Current Calculations

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Strength and Durability for Life CORROSION CONTROL. The Effect of Overhead AC Power Lines Paralleling Ductile Iron Pipelines

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

Unified requirements for systems with voltages above 1 kv up to 15 kv

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

Simulation of Ungrounded Shipboard Power Systems in PSpice

A Practical Guide to Dielectric Testing

Rule Fast Track Analysis for National Life Insurance Co.

ELECTRONIC POWER SYSTEMS

Instrument Transformers Application Guide

WHITE PAPER GROUND FAULT. Lowering the Limits for Ground Fault Detection

Electrical Grounding. Appendix C

Lecture Notes ELE A6

OPTIMIZING POWER SYSTEM PROTECTION FOR MODERN DATA CENTERS

Telecommunication Line Protectors

AC Generators. Basic Generator

SHORT CIRCUIT CURRENT CALCULATION AND PREVENTION IN HIGH VOLTAGE POWER NETS

TAN δ (DELTA) CABLE TESTING OVERVIEW AND ANSWERS TO FREQUENTLY ASKED QUESTIONS. What Is Tan δ, Or Tan Delta?

13 common causes of motor failure

How To Wire A Three Phase, Single Phase, Wye Transformer

Product Guide. Low voltage grounding system. Answers for industry.

PORTABLE GENERATORS AND OSHA CONSTRUCTION REGULATIONS

AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE

GE Multilin technical note

Beware; the Multiwire Branch Circuit

Radial Distribution Test Feeders

ECE 586b Course Project Report. Auto-Reclosing

BALANCED THREE-PHASE CIRCUITS

Grounding and Electrical Safety of Shore Power Supply and DC Stinger System Design

PacifiCorp Original Sheet No. 476 FERC Electric Tariff, Substitute 6 th Rev Volume No. 11 APPENDIX 2 TO SGIP

Electrical Resistance Resistance (R)

How Much Voltage Drop Is Acceptable?

DC GROUND FAULT DETECTION PROVIDED FOR UNINTERRUPTIBLE POWER SUPPLIES

HAZARDS, INCLUDING SHOCK, ARC FLASH AND FIRE

Insulation resistance testing

Electrical safety requirements in DC distribution systems

Chapter 9 Balanced Faults

TA Kahraman Yumak ELK412 - Distribution of Electrical Energy Lab. Notes v Spring web.itu.edu.tr/yumakk. Distance Protection

High Voltage Power Supplies for Analytical Instrumentation

Avoiding AC Capacitor Failures in Large UPS Systems

ARMY TM NAVY NAVFAC MO-912 OPERATION, MAINTENANCE AND REPAIR OF AUXILIARY GENERATORS

INTERNATIONAL STANDARD

Atlanta Chapter IEEE Industry Applications Society

Power Quality for Information Technology System

10A-C GENERATOR AND MOTOR PROTECTION

AC-Synchronous Generator

Three-Phase AC Power Circuits

Power-factor testing of rotating machinery is another valuable test

Electrical Safety Tester Verification

Chapter 11 Balanced Three-Phase Circuits

HIGH FREQUENCY TRANSIENT SURGE SUPPRESSORS

The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies

HIGH VOLTAGE SHORE CONNECTION

November Stray Voltage Test Procedure for Electrical Contractors

Corner-Grounded Delta (Grounded B Phase) Systems

ACCURACY OF POTENTIALTRANSFORMERS

HPS Universal. Single and Three Phase Potted. Buck-Boost Transformers. Buck-Boost Applications & Standard Specification... 80

Effective: September 10, 2006 Vermont Attachment 1 to Rule Public Service Board Page 1 of 6

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

PROTECTION AGAINST ELECTRIC SHOCK by John Ware

Typical Data Requirements Data Required for Power System Evaluation

employed to ensure the continuing reliability of critical systems.

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

Residual Current Circuit Breaker

Substation Grounding Study Specification

Advancements in Lightning Test Services

EVALUATION OF CURRENTS AND CHARGE IN SURGE PROTECTIVE DEVICES IN LOW-VOLTAGE DISTRIBUTION NETWORKS DUE TO DIRECT LIGHTNING STRIKES

Grounding of AC generators and switching the neutral in emergency and standby power systems

3-Phase AC Calculations Revisited

TECHNICAL INTERCONNECTION REQUIREMENTS FOR DISTRIBUTED GENERATION. Micro Generation & Small Generation, 3-phase, less than 30 kw

Earthing Guidance Notes

Switchgear Application Issues for Mission Critical Power Systems, Part One

Power Quality Standards for Electric Service

Using Current Transformers with the 78M661x

Grounding Demystified

Transcription:

> the power to protect A Guide to High Resistance Grounding Part 2 of 4 www.i-gard.com

ABOUT I-Gard Our company I-Gard Inc., formerly known as IPC Resistors Inc., is growing from a resistor only company and to one that fully incorporates our ground fault protection line into the company. The ground fault protection product line has provided an exciting vehicle for growth and the new name I-Gard better reflects our technical and application focus. At the same time, we understand that our success in partnering in the global market achieved over the last 21 years has been built on designing and manufacturing high quality power resistors to meet our customer s specific needs and that will not change. We look forward to being your technical partner in the future for all of your power resistor and ground fault requirements. For application engineering assistance on high resistance grounding, please call us toll-free at 1-888-737-4787 (1-888-RESISTOR).

TABLE OF CONTENTS SUBJECT PAGE 1. Power System Grounding Basics...2 1.1 What Is Grounding?...2 1.2 What Is A Grounded System?...2 1.3 Are There Different Types Of System Grounding?...2 1.4 What Is The Purpose Of System Grounding?...3 1.5 Ground Faults...3 2. Disadvantages of Ungrounded Systems...4 2.1 What Is An Ungrounded System?...4 2.2 What Does IEEE Say About Ungrounded Systems?...5 2.3 Advantages of Grounding...5 3. Resistance Grounding Basics...6 3.1 What Is A Resistance Grounded System?...6 3.2 What Is A Low Resistance Grounded System?...6 3.3 What Is A High Resistance Grounded System?...6 3.4 Why Limit The Current Through Resistance Grounding?...6 4. Sizing the Neutral Grounding Resistor...8 4.1 What Are The Requirements For Sizing The Resistor?...8 4.2 Measuring The System Capacitive Charging Current...8 4.3 Rule Of Thumb For System Charging Current...9 4.4 Is There Any Problem To Applying A 5A Resistor To A System That May Only Have 1A Of Charging Current?...10 4.5 What Is The Probability That A 480V Industrial System 4000 Kva Would Require More Than A 5A Resistor?...10 4.6 What Are The Necessary Steps to Upgrade My System...10 1 - I-Gard - The Leader in Ground Fault Protection

2 DISADVANTAGES OF UNGROUNDED SYSTEMS 2.1 WHAT IS AN UNGROUNDED An ungrounded system is one in which there is no intentional connection between SYSTEM? the conductors and earth ground. However, in any system, a capacitive coupling exists between the system conductors and the adjacent grounded surfaces. Consequently, the ungrounded system is, in reality, a capacitively grounded system by virtue of the distributed capacitance. This is shown in Figure 2. FIGURE 2 Phase A Conductor Phase B Conductor Phase C Conductor Delta Configuration Under normal operating conditions, this distributed capacitance causes no problems and in fact serves to keep the phase voltages balanced about ground, as shown in Figure 3a. As a result, the phase conductors are stressed at only line-to-neutral voltage above ground. However, problems can arise under certain ground fault conditions. A bolted ground fault on one line results in full line-to-line voltage appearing on the other two phases. Thus, a voltage 1.73 times the normal voltage is present on all insulation on the ungrounded phase, as shown in Figure 3b. FIGURE 3 Each phase is at line-to-neutral voltage above ground.. Voltage relationships. Line-to-line voltage A B C Neutral point established by distributed capacitance. (a) NORMAL OPERATION Phase A and B are now at full line-to-line voltage above ground. A B C Phase C is now at ground potential. Negligible fault current flows as there is no return path back to the source. (b) GROUND FAULT ON PHASE C Ungrounded systems employ ground detectors to indicate a ground fault. These detectors show the existence of a ground on the system and identify the faulted phase, but do not locate the ground, which could be anywhere on the entire system. If this ground fault is intermittent or allowed to continue indefinitely the system could be subjected to possible severe over-voltages to ground, which can be as high as six or eight times phase voltage. This can puncture insulation and result in additional ground faults. 4 - I-Gard - The Leader in Ground Fault Protection

A second ground fault occurring before the first fault is cleared will result in a phaseto-ground-to-phase fault, usually arcing, with a current magnitude large enough to do damage, but sometimes too small to activate over-current devices in time to prevent or minimize damage. 2.2 WHAT DOES IEEE SAY ABOUT Ungrounded systems offer no advantage over high-resistance grounded systems in UNGROUNDED SYSTEMS? terms of continuity of service and have the disadvantages of transient over-voltages, locating the first fault and burn downs from a second ground fault. IEEE 242-1986 7.2.5 2.3 ADVANTAGES OF GROUNDING If the ground fault is intermittent (arcing, restriking or vibrating), then severe overvoltages can occur on an ungrounded system. The intermittent fault can cause the system voltage to ground to rise to six or eight times the phase-to-phase voltage leading to a breakdown of insulation on one of the unfaulted phases and the development of a phase-to-ground-to-phase fault. Overvoltages caused by intermittent faults, can be eliminated by grounding the system neutral through an impedance, which is generally a resistance, which limits the ground current to a value equal to or greater than the capacitive charging current of the system. The intentional connection of the neutral points of transformers, generators and rotating machinery to the earth ground network provides a reference point of zero volts. This protective measure offers many advantages over an ungrounded system, including: Reduced magnitude of transient over-voltages Simplified ground fault location Improved system and equipment fault protection Reduced maintenance time and expense Greater safety for personnel Improved lightning protection Reduction in frequency of faults. 5 - I-Gard - The Leader in Ground Fault Protection

7615 Kimbel St., Unit 1, Mississauga, Ontario Canada L5S 1A8 Phone 905-673-1553 Toll Free 1-888-737-4787 Fax 905-673-8472 www.i-gard.com