HIGH FREQUENCY TRANSIENT SURGE SUPPRESSORS
|
|
|
- Donna Chapman
- 9 years ago
- Views:
Transcription
1 HIGH FREQUENCY TRANSIENT SURGE SUPPRESSORS FOR PROTECTION OF MEDIUM AND LOW VOLTAGE MOTORS AND TRANSFORMERS is a unique high frequency transient overvoltage surge suppressor for the protection of motors and transformers from steep wave-front, short rise-time, high magnitude, spikes, surges and other transient voltages, generated by switching, lightning and other sources. The protective characteristics of : Eliminates inter-turn insulation failures Extends the life of machine insulation Eliminates multiple pre-strike and re-strike transients associated with vacuum and other switchgear Provides comprehensive insulation co-ordination at all practical surge magnitudes and rise-times
2 : Introduction Every year huge losses are incurred by end-users because of insulation failures of medium voltage (3kV - 40kV) motors, and dry-type transformers. This can be caused by: Switching transients associated with vacuum and other switchgear resulting in expensive insulation failures of motors and dry-type transformers. Multiple pre-striking and re-striking (re-ignition) at the motor or transformer terminals. Protection Provides comprehensive protective characteristics at all practical surge magnitudes and rise-times for insulation co-ordination. Conforms with both the CIGRë and IEEE motor impulse voltage withstand recommendations, as shown in the additional technical document as Fig 4. Halves the magnitude of steep wave-front surges impinging on the load terminals by providing a matched cable terminating impedance under transient conditions, thereby eliminating refraction of steep wave-front surges (i.e. eliminates voltage doubling effects). Eliminates multiple pre-striking and re-striking transients associated with vacuum and other switchgear, by eliminating reflections of the pre-strike and re-strike current wave-fronts, and thus preventing high frequency current zeros in the contact gap of the switch. : Product Features Models to suit various voltages 400V to 40kV. versions Available in single phase and three phase units. Single-phase versions are suitable for installing in phase segregated terminal enclosures. Compact and easy to install Special compact versions that can be fitted within most motor/transformer terminal enclosures or switchgear panels. Class 1 Division 2 Certification (ExN, non sparking) As an option, surge suppressors may be ordered certified for use in potentially flammable atmospheres, (Class 1 Division 2 locations), temperature classes T1 to T5, to SABS (amended). Well proven Thousands of surge suppressors have been installed over the past 20+ years, on motors, generators and transformers, solving the problem of insulation failures and attendant repair and downtime costs. Benefits provided by Saves money by eliminating production downtime incurred due to insulation failures of motors and dry-type transformers. Protects new motors and dry-type transformers throughout their service life. Extends the life of motor and dry-type transformer insulation if retrofitted to existing motors and dry-type transformers in service. HIGH FREQUENCY TRANSIENT SURGE SUPPRESSORS Page 2 of 4 Cat. Zorc
3 : Applications Installed in the following industries: : Available Types type: Number Chemical. Petrochemical. Underground mining (gold, platinum, coal, other). Surface mining (coal, copper, uranium, iron ore, other). Metal beneficiation (steel, stainless steel, gold, platinum, copper and uranium refineries). Power generation (generators, power station auxiliaries). Pumping (water pumping stations, oil pipelines). Applied Specific applications on medium voltage motors, generators, and dry-type and oil immersed transformers:- Fans. Pumps. Compressors. Mills. Crushers. Refrigeration machines. Motor-generator sets. Mine winders. Conveyors. Underground and surface mini-substations and mobile substations. Ordering Examples: type M3-11KV-EXN type P3-3KV STANDARD - medium voltage - M1-3kV use on 3.3kV 1 phase 50/60Hz systems - M1-6kV use on 6.6kV 1 phase 50/60Hz systems - M3-3kV use on 3.3kV 3 phase 50/60Hz systems - M3-6kV use on 6.6kV 3 phase 50/60Hz systems - M1-11kV use on 11kV 1 phase 50/60Hz systems - M3-11kV use on 11kV 3 phase 50/60Hz systems - M1-15kV use on 15kV 3 phase 50/60Hz systems - M1-22kV use on 22kV 1 phase 50/60Hz systems - M1-33kV use on 33kV 1 phase 50/60Hz systems - M1-40kV use on 40kV 1 phase 50/60Hz systems Generators. Power station auxiliaries. Note: The prefix M indicates a motor mounting Zorc while a prefix P indicates a panel mounting Zorc. Other voltages on request. Induction & arc furnaces. Dry type transformers. COMPACT - medium voltage - M3C-3kV use on 3.3kV 3 phase 50/60Hz systems - M3C-6kV use on 6.6kV 3 phase 50/60Hz systems The compact is a 3 phase design fitted with 1 metre high voltage silicone rubber flexible leads. This facilitates easy installation into a motor/transformer terminal box and is directly connected to the motor/transformer terminals, thus reducing the required clearance associated with the conventional porcelain bushings. HIGH FREQUENCY TRANSIENT SURGE SUPPRESSORS Page 3 of 4 Cat. Zorc
4 LVZ - low voltage The low voltage has three standard models:- LVZ400 use on 380/400V 3 phase 50Hz systems. LVZ550 use on 525/550V 3 phase 50Hz systems. LVZ1100 use on 1000/1100V 3 phase 50Hz systems. Note: optimised RC surge suppressors are also available as customised designs for 15/24kV, and 30/36kV 3-phase 50/60Hz systems, generally for drytype transformer and oil immersed arc furnace transformer protection applications. Certain other, lower, and higher system voltages are available on request. Enquire from Strike Technologies for further details. Accessories IP55 sheet metal terminal cover with removable gland plate (for cable entry from below), provides a weatherproof, fully metal clad, floor standing enclosure for the type M3-3/6/11kV, enabling cabling to a motor, generator or transformer terminal box. Drawings can be supplied for enclosure Types:- Overall mechanical dimensions - guide Model Height Width Depth LVZ-400/550/ M1-3 & 6kV M1-11kV/M1-13kV M3/P3-3 & 6kV M3/P3-11kV M3C-3 & 6kV The above dimensions do not include the clearances required between surrounding equipment and the safe distances for the applied voltages. H W D Dimensions and mounting details are available on request from Strike Technologies. Refer to drawings for general specifications ENC-3/6KV-M3: ENC-11KV-M3: IP55 enclosure for types M3-3kV or M3-6kV IP55 enclosure for type M3-11kV Distributed by: Preferred connections of surge suppressors HIGH FREQUENCY TRANSIENT SURGE SUPPRESSORS Page 4 of 4 Cat. Zorc
5 APPLICATION: - PROTECTION OF MOTOR & TRANSFORMERS FROM SWITCHING SURGES * Function & Testing : Zorc Surge Protection PAGE 1 OF 4 The latter is extremely severe and cannot be tolerated by motors and dry-type transformers. Zorc technical details for protection of low and medium voltage motors and transformers. Steep Wave-Front Surge Problems A steep fronted surge comprises a step-change in voltage or current (without reference to earth), with rise-times in the order of 0.1-2µ s. Steep wave-front travelling waves are injected into a cable during the process of switching of motors and transformers, when a pre-strike or re-strike occurs across the closing or opening contact gap of the switch. Steep wave-front surges may also be generated by: Direct lightning strikes, from flashover across insulators, or from induced surges caused by lightning and other atmospheric discharges. Arcing earth faults on unearthed, reactance, or capacitance earthed power systems. Because the motor or transformer load surge impedance is invariably high with respect to the cable surge impedance, the steep wave-fronts are reflected and refracted at the load terminals. Refraction causes the magnitude of steep voltage wavefronts to almost double when the wave-front impinges on the load terminals. During switching, reflection of pre-strike or re-strike current wave-fronts cause high frequency current zeros in the contact gap of the switch. Arc extinction occurs in switchgear capable of interrupting at the high frequency current zeros, and subsequent re-strikes result in the generation of multiple pre-striking transients. Thus, refraction and reflection of steep wave-fronts, caused by a mismatch of the cable and load surge impedances, is central to the generation of the severe multiple pre-striking and multiple-escalating re-striking switching transients associated with vacuum and other switchgear. (Fig. 1 and 2) Fig. 2 Multiple re-striking (re-ignition) during interruption of a motor starting current. i.e. Stalled tripping. Without a surge suppressor fitted. Ref: Publication 1. Motor Insulation Impulse Withstand Levels The ability of motors and dry-type transformers to withstand steep wave-front switching, lightning and other transient overvoltage phenomena is the lowest of all equipment generally connected to a three-phase power system: - Because a steep wave-front surge does not distribute itself evenly over the motor/transformer windings, but stresses the line-end coils more, the surge withstand ability of motors and dry-type transformers decreases with decreasing impulse wave-front rise-times, i.e. the steeper the surge wave-front, the more the stressing of the inter-turn insulation of the line-end coils. (Fig. 3) Fig. 1 Multiple pre-striking during routine motor switch-on. Without surge suppressor fitted. Ref: Publication 1. Other Switching Transients The following can also occur: - Current chopping and Virtual current chopping transients. The former is normally not severe because the voltage transient generated is not steep fronted, and the normal chopping currents of medium voltage switchgear are not high. Fig. 3 Percentage of voltage wave-front appearing across line-end coil as a function of rise-time. Ref: Publication 5. Cat. Tech-Zorc High Frequency Transient Surge Suppressors
6 APPLICATION: - PROTECTION OF MOTOR & TRANSFORMERS FROM SWITCHING SURGES * Function & Testing This contrasts with the protective characteristics of power surge arresters, which exhibit an increasing (or at best, a constant) spark-over/residual voltage characteristic for steeper impulse wave-fronts i.e., it is impossible for power surge arresters to provide adequate insulation coordination at all practical impulse magnitudes and risetimes. In addition, power surge arresters provide protection with respect to earth, or between phases, whereas steep wavefront surges are step changes in voltage without reference to earth (often crossing earth potential) which stress the inter-turn insulation of the line-end coils of motors and dry-type transformers. (See Fig. 1 and 2). In service, there is an inevitable and unpredictable degradation of motor and transformer insulation as a result of the effects of temperature, vibration, shrinkage of insulation (resulting in loosening of a coil within a slot and subsequent chafing), environmental and atmospheric conditions, the number, magnitude and rise-times of transient over-voltage applied to the motor, etc. PAGE 2 OF 4 It is well documented that routine motor switch-on operations can result in surges of up to 4pu with rise times of 0.1-1ms, and stalled tripping operations can result in surges of 5-6pu with rise times of 0.1-1ms. Note 1pu = Ö 2 Ö 3.V L- L These surges are significantly higher than the motor withstand levels given by the IEEE and CIGRë curves. (Fig. 4) : How Works The surge suppressor is a unique voltage and frequency dependent cable-terminating network comprising of, capacitors, resistors and Zinc Oxide (ZnO) non-linear arresters. (Fig. 5) There are no international standards which lay down requirements regarding medium voltage motor insulation impulse withstand levels, either at the point of manufacture or over the intended service life of the motor. However, the CIGRë Working Group and the IEEE working group on the impulse strength of AC rotating machines, give some guidance as to what can be expected in practice. The IEEE curve takes the effects of ageing into account. (Fig. 4) Cigré : Withstand level given by 5 manufacturers IEEE : Recommended withstand value taking into account ageing. Fig. 5 Patented circuit and technique. Normal mains frequency conditions: the impedance of the capacitive elements is very high, effectively "disconnecting" the resistive components from the system and minimising heat dissipation and stressing of these elements. High frequency transient conditions: the impedance of the capacitive elements is low with respect to the resistive elements, effectively "inserting" the resistive components in the power system as a cable-terminating network, i.e. voltage refraction and reflection of steep wave-fronts are minimised, voltage doubling is avoided, and high frequency re-strike current zeros in the switch are eliminated when cable terminating resistors have a value of Zc R 3 Zc, where Zc is the cable surge impedance. (Ref: Publication 4.). This eliminates multiple pre-striking and re-striking transients associated with vacuum and other switchgear. (Fig 6 & 7) Fig. 4 Impulses withstand levels of medium voltage motors. Showing unsuppressed switching surge magnitudes and rise-times, and insulation coordination provided by. Fig. 6 Clean switch-on of motor With surge suppressor fitted, showing elimination of multiple pre-striking. Ref: Publication 1. Cat. Tech-Zorc High Frequency Transient Surge Suppressors
7 APPLICATION: - PROTECTION OF MOTOR & TRANSFORMERS FROM SWITCHING SURGES * Function & Testing PAGE 3 OF 4 Trigger Point Under high magnitude steep wave-front conditions, the ZnO arresters (having a knee-point voltage of 1-2 pu) "trigger", providing a very low resistance in series with the capacitive elements, i.e., a suitably low absolute limit is provided to the magnitude of a steep wave-front at the load terminals, and that portion of a steep wave-front which exceeds this limit is sloped to a value within the IEEE recommended motor insulation withstand levels. Cable Impedance The cable surge impedance Zc is independent of cable length, and does not vary widely for different cable types and sizes, i.e., a resistance value of 30 ohms for the suppressor, satisfying the condition Zc R 3 Zc, is suitable for virtually all installations, and is independent of cable length, motor size and voltage. Heat Dissipation The value of Capacitive Elements is optimised to minimise the heat dissipation and stressing of the resistive elements under normal mains frequency conditions while still performing its function as a "frequency dependent switch" and as a "wave sloping capacitor" under high frequency transient conditions. Clamping Voltage With the circuit, ZnO gapless non-linear arresters, with a clamping voltage low enough to protect the inter-turn insulation of the line-end coils, i.e. less than 2pu, where, 1pu = Ö 2 can be Ö 3.V L-L used, because the voltage across the non-linear elements is negligible under normal mains frequency operating conditions. : Installation surge suppressors may be installed in any orientation (including upside down) on the machine side of the associated medium voltage motor/generator/transformer switch, in the following positions (in order of preference from a surge protection point-of-view): - In the motor/generator/transformer terminal box, connected from each phase to earth. Cabled to the motor/generator/transformer terminal box via 2 a 3-core cable (25mm minimum), plus earth conductor (in accordance with local regulations). In line with the motor/generator/transformer supply cable, shunt connected from each phase to earth. In the associated motor/generator/transformer switch panel, connected from each phase to earth. Convenient mounting brackets or clamps are provided. Connections In the case of surge suppressors with porcelain bushings, care should be taken to use flexible connections to the bushings to avoid vibration or shock being transmitted to the bushings, in service and during transportation (when pre-wired). In addition, care should be taken not to over tighten the nuts on the bushing and earth studs (maximum 20Nm). Use a spanner to hold the bottom nut while tightening the top nut. Flexible Leads In the case of surge suppressors with flexible insulated connection leads (M1-3KV, M1-6KV, M3C-3KV & M3C-6KV), the leads can be cut to length to suit the application, but should not be extended. These compact single-phase motor/ transformermounting units must be directly connected to the machine terminals. Earth Be sure to earth the suppressor earth stud to the machine earth or switchgear panel earth bar, and ensure the machine is earthed back to the system earth via the machine's cable earth conductor, in accordance with local regulations. Fig. 7 Single re-strike during interruption of a motor starting current With a surge suppressor fitted, showing elimination of multiple escalating re-striking. Ref: Publication 1. Fig. 8 Preferred connections of surge suppressors Cat. Tech-Zorc High Frequency Transient Surge Suppressors
8 APPLICATION: - PROTECTION OF MOTOR & TRANSFORMERS FROM SWITCHING SURGES * Function & Testing : Publication references Refer Publication 1 EPCC Report: Guide for the Application of Switching Surge Suppressors to Medium Voltage Motors, presented jointly by the South African Institute of Electrical Engineers and the Electric Power Co-coordinating Committee, at a seminar held on 19 August Refer Publication 2 Yelland, CP: New Developments in the Protection of Medium Voltage AC Motors from Steep Fronted Surges, SAIEE Industrial Power System Disturbances Symposium Proceedings, September Refer Publication 3 Pretorius, RE: Optimised Surge Suppression of High Voltage Vacuum Contractor Controlled Motors, IEE International Conference on Sources and Effects of Power System Disturbances, London, May Refer Publication 4 Pretorius, RE: The generation of travelling waves in cable connected motor circuits and the effects thereupon of RC surge suppression circuits, CSIR Special Report ELEK 90, December Refer Publication 5 Nailen, RE: Transient surges and motor protection. Ind. And Com. Power System Tech. Conference, Seattle, PAGE 4 OF 4 Distributed by: Cat. Tech-Zorc High Frequency Transient Surge Suppressors
9
10
11
12
13
14
15 APPLICATION: - PROTECTION OF MOTOR & TRANSFORMERS FROM SWITCHING SURGES * Function & Testing Cat. Tech-Zorc High Frequency Transient Surge Suppressors
Unified requirements for systems with voltages above 1 kv up to 15 kv
(1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements apply to
AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle
Scope This specification stipulates the minimum requirements for mechanically linked three-phase electronic sectionalizers, for use on outdoor medium voltage overhead lines of 15, 27, and 38 kv. Electronic
SF 6 Gas Insulated Switchgear Type SDF for 170 kv
Three Phase Encapsulated Type SF 6 Gas Insulated Switchgear Type SDF for 170 kv 06B1-E-0001 With Trustworthy Technology, Structure Fuji Electric as a manufacturer of comprehensive substation equipment
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information
Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC
LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS
LIMITING SHORT-CIRCUIT CURRENTS IN MEDIUM-VOLTAGE APPLICATIONS Terence Hazel Senior Member IEEE Schneider Electric 38050 Grenoble France Abstract The power requirements for large industrial sites is increasing.
Lightning Arresters P30027 18 KVA P30038 10 KVA. Description & Installation
Lightning Arresters P30027 18 KVA P30038 10 KVA Description & Installation Printed in USA 09/11 TO330 Rev. B Table of Contents Page 1.0 SCOPE 2 2.0 PRODUCT OVERVIEW 2 2.1 Intended Uses 2 2.2 Lightning
Video Camera Installation Guide
Video Camera Installation Guide The intent of this guide is to provide the information needed to complete or modify a video camera installation to avoid lightning and induced power surge damage. This guide
Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components
Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components Course No: E02-010 Credit: 2 PDH Boris Shvartsberg, Ph.D., P.E., P.M.P. Continuing Education
AND8008/D. Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE
Solid State Control Solutions for Three Phase 1 HP Motor APPLICATION NOTE INTRODUCTION In all kinds of manufacturing, it is very common to have equipment that has three phase motors for doing different
RC NETWORKS SALES GUIDE
SALES GUIDE INTRODUCTION TO Recent developments in electronic equipment have shown the following trends: Increasing demands for numerical control machines, robotics and technically advanced appliances
The Intelligent AX1 Switchgear for Medium Voltage
The Intelligent AX1 Switchgear for Medium Voltage Leif Lundin, Manager of Research and Development, Division Medium Voltage and Compact Substations, ABB Distribution, Sweden Abstract The newly launched
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS
MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS Meher Capacitors offers reliable and innovative products and solutions in the fields of Reactive Power Compensation, Power Quality and Energy
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60071-2 Third edition 1996-12 Insulation co-ordination Part 2: Application guide This English-language version is derived from the original bilingual publication by leaving out
Lightning current simulation in the laboratory - parameters, procedures and test equipment -
Lightning current simulation in the laboratory - parameters, procedures and test equipment - Dipl.-Ing. J. Schönau, Dr.-Ing. M. Naß, CE-LAB GmbH Prof. Dr.-Ing. F. Berger, Ilmenau University of Technology
Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller
Overview/Modes of Operation Bulletin 150 Smart Motor Controller The SMC-3 is a compact, simple to use, solid-state motor controller designed to operate 3-phase motors. It features a built-in overload relay
Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.
Power Voltage Transformers for Air Insulated Substations THE PROVEN POWER. Introduction Trench Power Voltage Transformers (Power VTs) combine the attributes of an inductive voltage transformer with the
Discussion on Class I & II Terminology. IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA
Discussion on Class I & II Terminology IEEE PES Transformers Committee Fall Meeting 2011 Boston, MA What is Class I & II? C57.12.00 2010 is the only document we have that defined these terms. 5.10 Insulation
RM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
Power surges can also be generated by equipment in your facility such as:
Power Quality Surge Suppressors What is Surge Protection A surge suppressor can be the first and best defense against the instant or gradual destruction of electrical equipment. Compared to the replacement
2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?
Extra Questions - 2 1. A straight length of wire moves through a uniform magnetic field. The e.m.f. produced across the ends of the wire will be maximum if it moves: a) along the lines of magnetic flux
MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV.00 2012.4
CE - BF - C - en - REV.00 2012.4 APPLICATION CE-BF Switchbords up to 40.5 kv are designed for use in public and industrial distribution system up to 40,5KV for the operation and protection of lines, transformers,
New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance
New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance Dennis W. Lenk, Fellow, IEEE Abstract-- This paper examines performance
ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU
ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU George CURCANU, Constantin ILINCA, Ilie SBORA ICMET Craiova, Romania, Calea Bucuresti 144, phone:
Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements
NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems Safe energy distribution that meets the highest industrial requirements NATUS switchgear systems your advantages minimal use of insulant
0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N
55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils
R.C.C.B. s two-pole LEXIC
87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics...
UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution
UniGear ZS1 Medium voltage, arc proof, air insulated switchgear for primary distribution UniGear ZS1: an innovative solution for all installation requirements ABB UniGear is medium voltage metal-clad,
3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & 8 3. 4.0 Instructions For Installation, Operation & Maintenance
SPECIFICATION FOR LOW VOLTAGE SWITCHBOARD SEN I N D E X Description 10 STANDARD TECHNICAL REQUIREMENTS 11 Standards 12 General Operating Conditions 13 General Description Of Switchboard 131 Structure 132
LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A - 220 V AC coil
Product data sheet Characteristics LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 -
vacon ac drives for mining & minerals
vacon ac drives for mining & minerals 1 strong experience in mining & minerals Vacon AC drives are robust to handle your most demanding requirements from simple ventilation to the most complex load sharing
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms
Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms ABB innovations for changing demands ABB (www.abb.com) is a leader in power and automation technologies that enables utility
Secondary Unit Substations
14 SWITCHGEAR Secondary Unit Substations Overview Siemens offers a wide variety of unit substation designs to meet customer requirements. A unit substation consists of one or more transformers mechanically
www.siemens.com/energy High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.
s www.siemens.com/energy High Voltage Circuit Breakers AP Type 7.5 kv to 800 kv Answers for energy. The AP High Voltage Circuit Breakers Available up to 800 kv Decades of our experience in high voltage
Electrical Grounding. Appendix C
Appendix C Electrical Grounding Low-Voltage Equipment Grounding The most frequently cited Office of Safety and Health Administration (OSHA) electrical violation is improper occupational grounding of equipment
Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution
Medium Voltage Products ZN1 12 kv arc-proof air-insulated switchgear for primary distribution ZN1 an innovative switchgear for power distribution requirements ABB ZN1 primary distribution switchgear is
Pressure monitoring equipment for oil-sf 6. bushings, type GOEK
Pressure monitoring equipment for oil-sf 6 bushings, type GOEK Installation and maintenance guide 5693 827-6 en, Rev. 3, 2002-01-30 This document must not be copied without our written permission, and
SURGE PROTECTIVE DEVICES
SURGE PROTECTIVE DEVICES 1. INTRODUCTION In order to ensure safety of people, protection of equipment and, to a certain extent, continuity of supply, insulation co-ordination aims at reducing the likelihood
MNS is Switchgear System Technical Overview
Switchgear System Technical Overview Innovative Design ABB s innovative MNS is concept combines the long term experience, energy efficiency, grid reliability and industrial productivity of the well-known
Protection from Short-circuit
Protection from Short-circuit Back-up Fuse-Link with ÜLA (controlled power dissipation) Test device for tripping device Special version with threat High-voltage Fuse-Link for voltage transformers (HSW)
MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003
MiCAFIL 1 RIP Technology Z. Zic 09/2003 )XQFWLRQRI+LJK9ROWDJH%XVKLQJ Uncontrolled (natural) electrical field Capacity-controlled electrical field %XVKLQJV0DLQ,QVXODWLRQ6\VWHPV 7\SH 0DLQ,QVXODWLRQ +RXVLQJFRYHU
Circulating Current Relay. Type IRXm
Circulating Current Relay Type IRXm ABB a global technology leader ABB is a global leader in Power and Automation technologies that enable utility and industry customers to improve performance while lowering
Three-phase monitoring relay CM-PFE
Data sheet Three-phase monitoring relay CM-PFE The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251 005 S0012 Characteristics
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS
SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive
Electronic timer CT-VBS.17+18 OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F3 Approvals A culus E CCC CT-VBS a Circuit diagram b Marker label Marks a CE b C-Tick Order
Single-phase (220...240 V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring Undervoltage, Overvoltage, Window
GUIDELINES TO INSTALL, OPERATE AND MAINTAIN HT CAPACITORS & IT S ASSOCIATED EQUIPMENT
GUIDELINES TO INSTALL, OPERATE AND MAINTAIN HT CAPACITORS & IT S ASSOCIATED EQUIPMENT GENERAL: 1. The selection of switchgear for switching the capacitors should be done carefully. The circuit breaker
BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview
BETA Switching Siemens AG 200 5TT5 Insta contactors, AC technology Overview The 5TT5 Insta contactors are equipped with an AC magnetic system and are ideal for use under harsh conditions. The auxiliary
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1. 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.
2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV 16346-1 2a. Section 16346 INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std. Relays) Part 1 General 1.1 CONDITIONS AND REQUIREMENTS: A. Refer to
Power transformers. Special transformers Railway
Power transformers Special transformers Railway A leader in railway systems Our compact and low-weight transformers fully comply with the customer s specifications. The products are developed together
Series 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
Line Reactors and AC Drives
Line Reactors and AC Drives Rockwell Automation Mequon Wisconsin Quite often, line and load reactors are installed on AC drives without a solid understanding of why or what the positive and negative consequences
Contact expander modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact expansion module for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs:
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
Mylar polyester film. Electrical Properties. Product Information. Dielectric Strength. Electrode Size. Film Thickness
Product Information Mylar polyester film Electrical Properties Mylar offers unique design capabilities to the electrical industry due to the excellent balance of its electrical properties with its chemical,
ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.
POWER SUPPLY SYSTEMS AND ELECTRICAL EQUIPMENT FOR DESALINATION PLANTS Y.M. Hamud and A.H. Anwar Abu Dhabi Water and Electricity Authority, Abu Dhabi, UAE Keywords : Electrical System, Network for Desalination,
13 common causes of motor failure
13 common causes of motor failure Application Note What to look for and how to improve asset uptime Motors are used everywhere in industrial environments and they are becoming increasingly complex and
Power Quality for Information Technology System
Power Quality for Information Technology System ITS OBVIOUS THE TOLERANCE IS DIFFRENT But What isn t Tobvious? HOW MANY OF YOU HAVE : A COMPUTER AT HOME? = Computers are not screens and Keyboards COMPUTERS
Digital Energy ITI. Instrument Transformer Basic Technical Information and Application
g Digital Energy ITI Instrument Transformer Basic Technical Information and Application Table of Contents DEFINITIONS AND FUNCTIONS CONSTRUCTION FEATURES MAGNETIC CIRCUITS RATING AND RATIO CURRENT TRANSFORMER
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
The following table shows approximate percentage wise the
SHORT-CIRCUIT CALCULATION INTRODUCTION Designing an electrical system is easy and simple, if only the normal operation of the network is taken into consideration. However, abnormal conditions which are
Reduction of Lightning Caused Interruptions on Electric Power Systems Reduction Des Compures Dues a la Faudre Dans Les Reseaux
Reduction of Lightning Caused Interruptions on Electric Power Systems Reduction Des Compures Dues a la Faudre Dans Les Reseaux Harold S. Brewer Product Manger Ohio Brass Resume L avenement d équipements
ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV
1. SCOPE This document details PowerSystems requirements for electrical testing of HV Equipment up to and including 33kV. 2. ISSUE RECORD This is a Reference document. The current version of Controlled
Contact expansion modules
Gertebild ][Bildunterschrift Kontakterweiterungen Contact for increasing the number of available contacts Approvals Zulassungen Unit features Gertemerkmale Positive-guided relay outputs: 4 safety contacts
FAQs-Main switchboard design criteria
FAQs-Main switchboard design criteria Q: What is the Australian standard for main switchboards? Current Australian standard is AS/NZS 3439.1: 2002 originating from IEC 60439. The new series of standard
e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN
e 2 ALPHA Medium Voltage Switchgear Data Sheet K-1.1.2 EN We create ideas with power! ELEKTROMETAL ENERGETYKA SA is a new Polish company providing solutions for electrical power engineering. Our services
25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp
Page 1 2015 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable Grounded Metal
Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
Power factor correction and harmonic filtering. Rectimat 2 Automatic capacitor banks. Catalogue. Building a New Electric World
Catalogue 2002 Automatic capacitor banks Building a New Electric World 0Contents Power factor correction 2 Power factor equipment selection guide 3 General technical data 4 Capacitors and banks 50 z 6
IEC 1000-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays
IEC 00-4-2 ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays Application Note July 1999 AN9612.2 Author: Wayne Austin The SP720, SP721, SP723, and SP724 are protection
Power Capacitor Units for improved power quality
Power Capacitor Units for improved power quality Applications for capacitors Reactive power compensation Most of the apparatus and loads connected to the electrical power system consume both active and
MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930. 2009 MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090930 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW reactors are components designed to improve the reliability
Telecommunication Line Protectors
TN CR 0025 Telecommunication Line s 1.1 The nature of telecom surges The telecom services considered in this report are transported on twisted pair. Each service has two wires, or lines, sometimes called
Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques
Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques Howard W. Penrose, Ph.D On behalf of ALL-TEST Pro, LLC Old Saybrook, CT Introduction Field and shop testing of
INTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 60076-11 First edition 2004-05 Power transformers Part 11: Dry-type transformers This English-language version is derived from the original bilingual publication by leaving out
Theory of Heating by Induction
CHAPTER 2 Theory of Heating by Induction INDUCTION HEATING was first noted when it was found that heat was produced in transformer and motor windings, as mentioned in the Chapter Heat Treating of Metal
Type: DILM32 10(24V50HZ) Article No.: 277247
Type: DILM32 10(24V50HZ) Article No.: 277247 Ordering information Rated operational current AC 3 400 V I e A 32 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors,
Current Limiting Protector For Systems rated 2.8-38kV and continuous currents through 5000A.
Current Limiting Protector For Systems rated 2.8-38kV and continuous currents through 5000A. Arc Flash and Arc Blast reduction Network protection SCADA adaptable Indoor/outdoor application Professional
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830
Type: DILM50(230V50HZ,240V60HZ) Article No.: 277830 Ordering information Rated operational current AC 3 400 V I e A 50 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase
49 Series - Relay interface modules 8-10 - 16 A. Features
Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE
LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE 380/415/690 Volt AC 50/65/80/100 ka 1. Product Guide Low Voltage Motor Control Centre CONTSTRUCTION Continuous "poured in place" gasket
UFES Active protection for switchgear
Active protection for switchgear ABB AG Oberhausener Strasse 4047 Ratingen, Germany Phone: +49 0-0 Fax: +49 0-7 77 Note: We reserve the right to make technical changes or modify the contents of this document
However, industrial applications may utilize a relay, which short-circuits the ICL path after the inrush sequence.
Application note for Inrush Current Limiters (ICL) Turning on electrical devices generally cause high inrush currents which can damage electronic components and cause interruption of the line voltage if
2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation
2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation 123 kv Inductive Fingrid (Finland). 18 Instrument transformers igh voltage INTRODUCTION Inductive voltage transformers are designed
Introduction. Harmonics and IEEE 519 Page 1 of 19
Introduction In an ideal power system, the voltage supplied to customer equipment, and the resulting load current are perfect sine waves. In practice, however, conditions are never ideal, so these waveforms
Typical Data Requirements Data Required for Power System Evaluation
Summary 66 Carey Road Queensbury, NY 12804 Ph: (518) 792-4776 Fax: (518) 792-5767 www.nepsi.com [email protected] Harmonic Filter & Power Capacitor Bank Application Studies This document describes NEPSI
The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies
The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies DATE: November 17, 1999 REVISION: AUTHOR: John Merrell Introduction In some short circuit studies, the X/R ratio is ignored when comparing
METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.
METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV tgood.com Energy. Fast. TGOOD produces over 5000 switchgear units annually for projects around the globe PRODUCT OVERVIEW Integral substation component
Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content
Charged cable event David Pommerenke, [email protected], 916 785 4550 Last update: Feb.23, 2001 Content Goal Energy sources, which may lead to CDE. Complexity of the different discharge modes. Possible
ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA
MRO Modularne Razdelilne Omare d.o.o. ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 2, 000 Ljubljana, LOVENIA MC GENERAL When to use? MC - modular switchgear cabinets are type-tested, factory built switchgears,
SECTION 16461 DRY-TYPE TRANSFORMERS
SECTION 16461 PART 1 - GENERAL 1.1 SECTION INCLUDES A. Furnishing and installation of and testing of cast resin dry type MV/LV distribution transformer in accordance with specifications and drawings. Any
Technical catalogue About KOLEKTOR ETRA has been acting as transformer manufacturer over more than 75 years. Specializing in the manufacturing of power transformers rating up to 500 MVA and 420 kv the
Case Studies in On-Line Measurement of PD in Motors Fed by Voltage Source PWM Drives
Case Studies in On-Line Measurement of PD in Motors Fed by Voltage Source PWM Drives G.C. Stone, I. Culbert, H.G. Sedding Qualitrol-Iris Power Mississauga, Ontario, Canada Abstract On-line partial discharge
FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES
01D351-GB FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES DOLOMIT FLOAT SWITCHES The DOLOMIT float switches find application in liquid level control in tanks and wells; they require connection
VCE VET ENGINEERING STUDIES
Victorian Certificate of Education 2013 SUPERVISOR TO ATTACH PROCESSING LABEL HERE STUDENT NUMBER Letter Figures Words VCE VET ENGINEERING STUDIES Written examination Section Wednesday 20 November 2013
Modeling of Transmission Lines
Modeling of Transmission Lines Electric Power Transmission The electric energy produced at generating stations is transported over high-voltage transmission lines to utilization points. The trend toward
Cahier technique no. 193
Collection Technique... Cahier technique no. 193 MV breaking techniques S. Théoleyre "Cahiers Techniques" is a collection of documents intended for engineers and technicians, people in the industry who
E-STOP relays, safety gate monitors
Unit features Safety features Gertebild ][Bildunterschrift_NOT_Sch.tuer_Licht Safety relay for monitoring E-STOP pushbuttons, safety gates and light beam devices Approvals Gertemerkmale Positive-guided
Automatic Transfer Switch-Controller ATS-C by Eaton. Automatic Transfer Switch- Controller ATS-C 96 and C 144
Automatic Transfer Switch-Controller ATS-C by Eaton Automatic Transfer Switch- Controller ATS-C 96 and C 144 Supply safety for low voltage energy distribution. Automatic Transfer Switch-Controller ATS-C
Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO 250447392
1 Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading By Ramandeep Kaur Aujla S.NO 250447392 ES 586b: Theory and applications of protective relays Department of