ENVIROSHEET TM SHEET MEMBRANE WATERPROOFING SYSTEM

Similar documents
Read and understand all installation instructions and precautions before installing. GENERAL APPLICATION INSTRUCTIONS

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

A. This Section includes rubberized asphalt sheet membrane waterproofing systems.

ITEM THERMOPLASTIC MEMBRANE ROOFING

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

SEAMS SEAMING USING SEAM TAPE

WATERPROOFING FOR CONCRETE STRUCTURES

Grace Waterproofing Systems

CREEK Technical Services, LLC

WATERPROOFING OF WET ROOMS

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

METHOD STATEMENT 006 TORCH APPLIED MEMBRANE TO BASEMENT WALLS

Maintenance & repair Solutions

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

DELTA Premium Moisture Management Systems for Foundations.

Please read the entire document before purchasing and installing any of these products

LAYING BLOCK AND BRICK

SECTION SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

Peel & Seal Self-Stick Roofing Solutions

Division 9. SignaFlor Pad and Pour Flooring System

INSTALLATION GUIDE. americanwick.com WICK (9425)

USER GUIDE Easier, Safer, Betta! WATERPROOFING

BLACK JACK ALL WEATHER ROOF COATING

Asphalt Shingle Application Requirements

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November l Water and water vapour barrier. l Factory controlled thickness

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS

SC2000 CEMENT BONDING PROCEDURES

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

TITLE: MASONRY PARAPET WALLS AND FLAT ROOF REQUIREMENTS 11/1/09

Herringbone Pattern Flooring

Vinyl Composition Tile Installation System

T R A N S F E R A B L E F U L LY

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER

Installation System. Existing Resilient Sheet Floors

G VYCOR DECK PROTECTOR

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

BITUMINOUS ROOF COATINGS, CEMENTS, PRIMERS AND ADHESIVES

Building Owners Guide to a Duro-Last System!

How to Install Hardwood Flooring Over a Sub Floor

How to repair your existing low slope flat roof.

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H

Water Damage & Repair

RECOATING AND RENEWING SPF ROOFING SYSTEMS

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

SECTION FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING General Materials Equipment...

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

NEOGARD. Preventive Maintenance Manual

Avoiding Air Barrier Pitfalls

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Roof Systems Overview

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

G VYCOR DECK PROTECTOR. For longer lasting decks, install Grace Vycor Deck Protector. It s an easy add-on to your deck projects.

DENSO WATERPROOFING SYSTEMS

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

SECTION STANDING SEAM METAL ROOFING

CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

BENTLEY ELEMENTS COLLECTION LVT

STEPS TO CONSTRUCTING A MOISTURE-RESISTANT FOUNDATION SOURCES OF MOISTURE IN NEW CONSTRUCTION. Natural ground slope

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

K2 STONE NATURAL VENEER

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

The AQUAFIN Approach to Concrete Repair

SECTION THERMOPLASTIC MEMBRANE ROOFING

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

High Performance Building Materials SCREEDS REPAIR MORTARS LEVELLING & SMOOTHING WATERPROOFING TILE ADHESIVES & GROUTS PRIMERS & ADDITIVES

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick

Quality You Can Trust Since From North America s Largest Roofing Manufacturer

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Residential Roofing Guide

Roofing Systems. New Applications / Re-Roofing / Maintenance

Waterproofing construction Joints

Wecryl Waterproofing System under surfacing supplied by others

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

NRDCA 400 GUIDELINE FOR FIELD APPLICATION of LIGHTWEIGHT INSULATING CONCRETE REROOFING/RECOVER SYSTEMS

GUIDE SPECIFICATION COMBINATION SURFACE SYSTEM FOR NEW HOT MIX ASPHALT TENNIS COURTS I. PART 1 - GENERAL

WATERPROOFING SikaProof -A TECHNOLOGY

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE SYSTEM DESCRIPTION TORCH SYSTEM OVER POLYISO (15,17,19 YR) TH/BS-TH/CS

GigaCrete Specification PlasterMax

12.1 Schlüter -KERDI-BOARD

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

SikaProof A Technology

Retail Price List 2015

Mineral waterproof coating PCI Dichtschlämme

Chapter 3 Pre-Installation, Foundations and Piers

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

CHAPTER 6 ASPHALT ROLL ROOFING

Warranty Information TABLE OF CONTENTS PROCEDURES FOR WARRANTY 2

Materials and Colors

Transcription:

product manual ENVIROSHEET TM SHEET MEMBRANE WATERPROOFING SYSTEM www.cetco.com

product manual ENVIROSHEET TM SHEET MEMBRANE WATERPROOFING SYSTEM CONTENTS SECTION 1: PRODUCT DESCRIPTIONS SECTION 2: APPLICATIONS SECTION 3: INSTALLATION GUIDELINES 3.1 Substrate Preparation 3.2 Substrate Priming 3.3 Detail Work SECTION 4: FOUNDATION WALLS 4.1 Membrane Installation 4.2 Penetrations 4.3 Termination At Grade 4.4 Under Slab Waterproofing SECTION 5: HORIZONTAL APPLICATIONS 5.1 Membrane Installation 5.2 Deck-to-Wall Corner Transition 5.3 Penetrations 5.4 Drains SECTION 6: INSPECTION AND REPAIR SECTION 7: FLOOD TESTING SECTION 8: PROTECTION COURSE SECTION 9: DRAINAGE COMPOSITE SECTION 10: BACKFILL SECTION 1 PRODUCT DESCRIPTION is a self adhering sheet system used for waterproofing concrete, masonry and wood. It is ideal for waterproofing foundation walls, tunnels, and split-slab construction such as plazas and parking decks either above or below grade. can be used on either interior or exterior subsurface applications. The system is a complete waterproofing system comprised of a durable sheet and associated accessory products. Membrane: is a 60-mil thick sheet waterproofing comprised of a 4-mil cross laminated polyethylene sheet laminated to a thick layer of rubberized asphalt compound. The sheet is 914 mm (36 ) wide by 66.7 feet (20.3 m) long. is formulated for temperature applications down to 50 F (10 C). The product is wound into rolls with a disposable silicone coated release paper backing. The edge of the sheets have a quick strip removal tape that allows excellent seam sealing ability. is packaged in 18.5 sq m (200 square foot) rolls. Rolls are individually packaged in corrugated cartons and shrink-wrapped 25 rolls per pallet. Enviroprimer WB: Enviroprimer WB is a water-based polymer emulsion primer designed to provide excellent adhesion of waterproofing to structural substrates. Apply in dry weather above 40 F (4 C) at a rate of 400-600 sq ft per gallon (37-55 sq m per 3.78 liters). Enviroprimer SB: Enviroprimer SB is a solvent-based primer designed to provide excellent adhesion of waterproofing to structural substrates. Apply in dry weather above 25 F (-4 C) at a rate of 27-32 sq m per 3.78 liters (300-350 sq ft per gallon). Liquid Flashing: is a trowel-grade waterproofing mastic designed for a variety of detailing uses including, fillet material at inside corners; flashing material around drains, protrusions, and penetrations; sealing material at grade terminations and overlap seams; and repair material for small concrete surface defects. AQUADRAIN: Subsurface drainage composite consisting of dimpled, high-impact polystyrene core and filter fabric. Designed to promote positive drainage and protection. MATERIAL STORAGE Protect all materials from precipitation and physical damage. All materials should be stored above 50 F (10 C). Do not store at temperatures above 90 F (32 C) for extended periods. Store all products in a dry area away from flames, sparks, high heat, and prolonged exposure to direct sunlight. During outside storage at jobsite, provide tarpaulin cover on top and all sides, allowing for adequate ventilation. Do not double stack pallets. PRECAUTIONS Avoid inhalation of vapor or spray mist from primers or mastic. Ensure adequate ventilation. Avoid contact of primers and mastic with skin. Protective clothing is recommended. Contact areas should be thoroughly washed with water. Avoid ingestion of material. If ingestion occurs, contact a physician immediately. Additional safety information is contained in the MSDS Sheet. SECTION 2 APPLICATIONS is ideal for waterproofing structural concrete, masonry, and wood surfaces where the in-service temperature will not exceed 130 F (54 C). can be applied to foundation walls, tunnels, and earth sheltered structures. It can also be used in split-slab construction, both above and below grade, such as plaza decks, balconies, planters, and parking decks. Interior uses include mechanical rooms, kitchens, bathrooms, and laboratories. LT Membrane: is also manufactured in a low temperature grade - LT - for application temperatures 25 F (-4 C) to 16 C (60 F). LT is 60-mils thick by 36 wide by 66.7 long; 200 sq ft per roll. - 2 -

LIMITATIONS should not be applied to areas that will be permanently exposed to direct sunlight. Do not use as a wearing surface. Do not use as a pond or tank liner unless fully protected by a concrete slab. Do not apply or accessory products to frozen, frosted or wet surfaces. Do not apply s over substrates containing petroleum solvents, fuels or oils. s are compatible with aged asphalt and coal tar products. They are incompatible with creosote, pentachlorophenol, and joint sealants containing polysulfide polymer. Tile set in thin-set mortar is not recommended over s. Use a cement-based mortar setting bed with a minimum thickness of 30 mm (1-1/4 ) as recommended by the Ceramic Tile Institute. is not intended to provide the primary waterproofing for expansion joints. Laboratory testing has shown that is capable of bridging cracks in concrete up to 1.5 mm (1/16 ). APPLICATION STANDARDS waterproofing meets the requirements of the following specifications: AIA MASTERSPEC Section 07100 CSI SPECTEXT Section 07110 Corps of Engineers CEGS-07111 Department of the Navy NFGS-07111 Federal Construction Guide Specification 07111 American Railway Engineering Association 29-2-4 SECTION 3 INSTALLATION GUIDELINES Before installing read this installation manual to gain familiarity with specific procedures and applications. Apply when temperature is 50 F (10 C) and above. Apply LT when temperature is 25 F (-4 C) to 60 F (16 C). For applications not covered in this manual, contact CETCO for specific installation guidelines. 3.1 SUBSTRATE PREPARATION Prior to installing, the substrate must be properly prepared. Substrate may be concrete, steel, wood or masonry block. Substrate should be clean, smooth, monolithic and free of voids and sharp protrusions. Apply only to a properly prepared substrate. CONCRETE SURFACE PREPARATION Concrete should be dry and have a minimum 7 days curing time (14 days for lightweight structural concrete). If concrete is placed over a non-vented metal pan deck, double the drying time. Use form release agents which will not transfer to the concrete. Remove forms as soon as possible from below horizontal deck slabs to prevent entrapment of excessive moisture. Cure concrete with clear, resin-based curing compounds containing no oil, wax, or pigment. Allow concrete to thoroughly dry after rain. Repair all concrete surface defects such as spalls or poorly consolidated areas with cement based patching material. Remove sharp protrusions and form match lines. MASONRY WALL SURFACE PREPARATION Strike all mortar joints flush to the face of smooth masonry block or apply a parget coat to entire surface of rough masonry block with cement based material. Remove any mortar clumps attached to the face of the masonry. CONSTRUCTION JOINTS should be installed in all applicable concrete construction joints. is a flexible, expanding strip Waterstop designed for nonmoving concrete construction joints. Expansion joints should be sealed with appropriate joint filler and sealant. is not a substitute for proper joint sealing design. Prestrip all cracks and construction joints over 2 mm (1/16 ) wide with a 225 mm (9 ) wide strip. 3.2 SUBSTRATE PRIMING Apply properly stirred Enviroprimer over the entire surface with a chemical resistant roller or brush. Allow primer to dry until it does not release when touched. If dusty conditions exist on the jobsite, apply as soon as primer has dried. Reprime all areas contaminated with dust or dirt prior to installation. Reprime all surfaces where is not applied within 24 hours. Drying time for primer may be longer at cold temperatures. Most metal surfaces do not require priming but must be clean, dry and free of paint, rust or other contaminant. 3.3 DETAIL WORK WALL-TO-FOOTING JOINTS Option 1 (Detail 1): Detail wall-to-footing joint with a 19 mm (3/4 ), 45 angle fillet of. Center a 300 mm (12 ) strip of over the joint. Place wall and continue it down the wall and onto the footing a minimum of 150 mm (6 ). Terminate with. Seal all overlaps within 300 mm (12 ) of the wall/ footing joint, substrate transitions, and T-Joints with. Option 2 (Detail 2): Apply to within 25 mm (1 ) of base of wall. Install a 19 mm (3/4 ) fillet of and extend mastic onto and footing a minimum of 65 mm (2-1/2 ), 90-mils thick. www.cetco.com

product manual ENVIROSHEET TM SHEET MEMBRANE WATERPROOFING SYSTEM Option 3 (Detail 3): If the bottom of the interior floor slab is a minimum of 150 mm (6 ) above the top of the footing, the may be terminated at the base of the wall. Form a 19 mm (3/4 ) fillet of in corner and extend mastic 2.3 mm (90-mils) thick up the wall and onto the 65 mm (2-1/2 ). INSIDE AND OUTSIDE CORNER TRANSITIONS Prestrip all wall-to-wall inside and outside corners (vertical) with a 300 mm (12 ) wide piece of centered over the corner. Press tightly to assure full contact to primer. Cover with full sheet of to ensure 2-ply coverage (Detail 4). PENETRATIONS Apply to within 25 mm (1 ) of any penetration. Then apply a 19 mm (3/4 ) fillet of around the base of the penetration. Extend mastic onto both the penetration and the a minimum 65 mm (2-1/2 ) at a thickness of 2.3 mm (90-mils) (Detail 5). AQUADRAIN 300 mm (12 ) strip Detail 1 - Foundation Wall (Slab on Footing) Option 1 AQUADRAIN Term bar with tooled bead of CETSEAL Term bar with tooled bead of CETSEAL SECTION 4 FOUNDATION WALLS Properly prepare substrate, complete all detail work and prime prior to installing. 4.1 MEMBRANE INSTALLATION For ease of installation, apply in lengths no greater than 8-feet (2.4 meters). Remove release paper to apply sheet adhesive side down. Remove clear plastic quick strip along edge to expose rubberized asphalt compound. Overlap all seams and endlaps a minimum of 65 mm (2-1/2 ). Firmly press into place and roll all seams to insure full adhesion. Apply a bead of at all terminations at the end of each days work. 4.2 PENETRATIONS Apply to within 25 mm (1 ) of any penetration. Then apply a 19 mm (3/4 ) fillet of around the base of the penetration. Extend mastic onto both the penetration and the a minimum 65 mm (2-1/2 ) at a thickness of 2.3 mm (90-mils) (Detail 5). In areas where multiple penetrations are close together, it may be impractical to cut the to fit between the penetrations. Apply 19 mm (3/4 ) thick around the penetrations and flash 90-mils thick covering the area between the penetrations. Extend the mastic 90-mils thick onto the penetrations a minimum 65 mm (2-1/2 ). 4.3 TERMINATION AT GRADE Terminate the at grade level. Press edge firmly against the wall using a hand roller or similar device. Secure top edge with a fastened termination bar or reglet and seal with a tooled bead of CETSEAL (Detail 6) above grade shall be covered with UV resistant flashing or architectural finish material and not left exposed to prolonged sunlight. 4.4 UNDER SLAB WATERPROOFING If waterproofing under the structural floor slab is required, contact CETCO for applicable products and installation guidelines. Detail 2 - Foundation Wall (Slab on Footing) Option 2-4 -

AQUADRAIN Term bar with tooled bead of CETSEAL 19 mm (3/4 ) fillet of with 2.3 mm (90-mil) thick extension onto pipe Penetration Detail 3 - Foundation Wall (Elevated Floor Slab) Option 3 installed to within 25 mm (1 ) of penetration Detail 5 - Single poured-in-place penetration detail Concrete wall Tooled bead of CETSEAL Rigid termination bar fastened 300 mm (12 ) on center (optional) 300 mm (12 ) strip centered at corner Detail 4 - Wall-to-Wall Inside Corner Detail Full sheet of installed over strip Detail 6 - Grade termination with rigid termination bar and tooled bead of CETSEAL. Roll terminating edge firmly. www.cetco.com

product manual ENVIROSHEET TM SHEET MEMBRANE WATERPROOFING SYSTEM AQUADRAIN SECTION 5 HORIZONTAL APPLICATIONS Properly prepare substrate, complete all detail work and prime prior to installing. 300 mm (12 ) strip Detail 7 - Earth-Covered Roofs and Tunnels require a double layer at the transition corner. 5.1 MEMBRANE INSTALLATION Apply from low to high point to allow a shingle effect for water drainage. Remove release paper to apply sheet adhesive side down. Remove clear plastic quick strip along edge to expose rubberized asphalt compound. Overlap all seams a minimum of 65 mm (2-1/2 ). Stagger all end laps. Firmly press into place and roll with a minimum 34 Kg (75-lb) padded roller. Apply a bead of at all terminations at the end of each days work. 5.2 DECK-TO-WALL CORNER TRANSITION Apply to within 25 mm (1 ) of wall. Apply 19 mm (3/4 ), 45 angle fillet of in corner. Apply strip on wall to just under the height of the wear surface and extending onto previously installed deck. Seal both edges of strip with 90- mil thick flashing of (Detail 9). 5.3 PENETRATIONS Apply to within 25 mm (1 ) of the penetration. Then apply a 90-mil thick layer of extending a minimum of 65 mm (2-1/2 ) onto the and up the penetration to just below the top elevation of the wearing course. Bentoseal CETCO waterproofing installed directly on top of compacted substrate Detail 8 - CETCO waterproofing system under the floor slab with on the foundation wall (non-hydrostatic condition). 5.4 DRAINS Apply 2.3 mm (90-mil) thick layer of extending from drain throat to a 150 mm (6 ) radius around drain collar on the deck. Apply full sheet of over drain and cut out flush with inside wall of drain. After has cured, install drain clamping ring in 90-mil (2.3 mm) bed of so that it extends under the clamping ring (Detail 10). Seal all laps within 300 mm (12 ) of all corners and seal all T-Joints with. Apply a bead of at all terminations at the end of each days work. 6.0 INSPECTION AND REPAIR Inspect for tears, punctures, air blisters and unsealed seams prior to installing protection course. Remove all that is not fully adhered and repair with a patch extending 150 mm (6 ) onto existing, fully adhered. Repair any damaged areas or inadequately lapped seams with a patch extending 150 mm (6 ) onto existing, fully adhered. Seal edges with. - 6 -

Membrane strip 7.0 FLOOD TESTING (If Required) Before flood testing ensure deck can withstand the dead load. Allow 24 hour cure time for installation prior to flood test. Flood with a minimum of 50 mm (2 ) of water. Repair any leaks prior to installing slab or wearing surface. 8.0 PROTECTION COURSE requires a protection course to avoid damage from other trades, construction materials and backfill. Ensure that the surface is clean and free of stones or other debris prior to the installation of protection course. Do not leave exposed to direct sunlight for any extended period of time. 3/4" (18 mm) fillet of Detail 9 - Deck-to-Wall inside corner detail. Drain Clamping Ring in bed of Line of topping cover Protect vertical applications the same day the is applied. Use applicable AQUADRAIN prefabricated drainage composite or protection course material approved by manufacturer. Adhere as necessary to with Enviroprimer SB or general construction adhesive. Do not puncture with attachment devices. Protect exposed at the top of the wall with weather-resistant flashing material such as aluminum, copper, or neoprene. Protect horizontal applications the same day the is applied or immediately after a successful flood test. Use applicable AQUAD- RAIN prefabricated drainage composite or protection course material approved by manufacturer. Adhere as necessary to with Enviroprimer SB or general construction adhesive. Alternate protection materials include 3 mm (1/8 ) and 6 mm (1/4 ) asphaltic hardboard. Apply asphaltic hard-board according to manufacturer s recommendations. Do not puncture with attachment devices. Use concrete bricks or plastic bar chairs when placing reinforcing steel on protection course over. 9.0 DRAINAGE COMPOSITE Good draining backfill should be used in conjunction with a foundation drain system to prevent hydrostatic conditions against the foundation. AQUADRAIN subsurface drainage composite is recommended to provide a consistent, high capacity flow path for water to the drain discharge pipe at the base of the wall. Full deck sheet Protection course not shown. collar extending into drain Detail 10 - Deck drain detail. CETCO recommends using a double stage drain for all deck drains. 10.0 BACKFILL Carefully place compactible well draining soil. Follow generally accepted practices for placing and compacting backfill. Backfill should be added in 150 mm (6 ) to 300 mm (12 ) lifts. Backfill material should be free of large rocks and other debris. Avoid damaging the waterproofing system with compaction equipment and backfill. www.cetco.com

1.800.527.9948 www.cetco.com 2014 CETCO. IMPORTANT: The information contained herein supersedes all previous printed versions, and is believed to be accurate and reliable. For the most up-to-date information, please visit www.cetco.com. CETCO accepts no responsibility for the results obtained through application of this product. CETCO reserves the right to update information without notice. Updated: MAY 2014 PM_ENVIROSHEET_AM_EN_201311_v1