ROCKWOOL Acoustic Membrane

Similar documents
Rockwool Cladding Roll

ProRox Slabs (formerly known as RW slabs)

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Rockwool Flexi Insulation Application Guide

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Hardrock Dual Density Range

Composite Panel Firewall Systems

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

Multi-layer Insulation Blanket for Roofs

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Rooflighting and Glazing

Mineral fibreglass insulation

AND MEMBRANES ROOFING UNDERLAYS.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

European Organisation for Technical Approvals

Fire Barrier Systems. For inhibiting the spread of fire and smoke in concealed spaces

IMPACT DAMAGE RESISTANT WALL SYSTEMS

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

ALUMINIUM. Product Data Sheet

Technical Specification Fire Blanket Firemaster Fire Protection-Cables Tray Fire Protection Department

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Peel & Seal Self-Stick Roofing Solutions

Architectural composite panels

ROXUL COMMERCIAL ROOFING. Understanding Climate Requirements That Drive Performance. roxul.com

Understanding BS EN 771-3: Aggregate concrete masonry units

CEILING SYSTEMS. CI/SfB (35) Xy April [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Section 2.3. Flat Roofs. Warm deck single ply membrane. Warm deck single ply membrane. Warm deck built-up felt/ mastic asphalt. Protected membrane

Steel-framed Walls. Insulation

Wardle Storeys. Reducing Rain Noise on Profiled Metal Roofing Systems Using DEDPAN DS2020 RDV

Product Data Sheet ROCKPANEL Rockclad

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Low Energy Low Carbon Buildings

Annex of the certificate (Page 1/6) Accreditation Scope

COMMERCIAL BUILDING APPLICATIONS

Twiga Insul. India's Leading Thermal and Acoustic Insulation. Insulating India

Stonewool Insulation for Thermal, Acoustic and Fire Safety Building Applications

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Technology at its best. Benefits

Formwork Direct International Ltd Phone No +44 (0151) Fax no +44 (0151)

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

DELTA Premium Moisture Management Systems for Foundations.

System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY

Physically Crosslinked Foam Insulation

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

European technical approval

Light-Weight Panels. High quality panels.

European Technical Approval ETA 13/0526

sound reduction systems for commercial, educational and industrial environments

FIREPROOF Panels Trimoterm

Roofing Systems. There are many different systems, each with it's own special requirements and benefits. Browse through all the options below.

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

Regulations Detail Sheet 1

metal Duil~ing manufacturers Association

FireSmart IRS Insulating Roof Screed

Sealfire W1000 Compound. (2 references for the same product) Fire Stopping and Sealing Product: Penetration Seals

STENCA PIPE. High quality pipe insulation.

Polymeric membrane for roof waterproofing

ROCKWOOL Insulation. 3. Composition/information on ingredients. 1. Identification of the substance/mixture and of the company. 4. First aid measures

Uniclass L31:N14:P7111 C1/SfB (16.9) Rn7 (J4) February Foundation Heave Protection

ALUMASC ROOF WATERPROOFING MEMBRANES EUROROOF MASTERGOLD ROOF WATERPROOFING MEMBRANE

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

Lightweight Partition Design for Residential and Commercial Buildings

Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery

Portable petrol storage containers

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

The assessment is described in the following pages which form integral parts of this certificate, which should be read in its entirety.

BETONYP building boards. The modern way of living.

INNOVATIONS. Economic Flat Roof Refurbishment with NOVOPROOF Sealing Systems. A Company of the SAARGUMMI Group

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

RHEPANOL RHEPANOL FK ROOF COVERING SYSTEM

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

MULTI ROOFING. Our Services.

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

CONTENTS. General conditions 2. Material requirements 3. Terms 4. Estimating shingle requirements 4. Roof preparation 6. Shingle application

Marine & Offshore Insulation. - products and constructions November 2009

Roof Insulation Building. Energy. Environment friendly e-library

Asphalt Shingle Application Requirements

Building Owners Guide to a Duro-Last System!

DENSO WATERPROOFING SYSTEMS

PB301 July Lightweight Building Solutions. Bushfire Protection.

Product Guide Specification

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

Basements. I n s u l a t i o n. Low Energy Low Carbon Buildings

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

Roxul Board Insulation Section Master Guide Specification (CAVITYROCK DD) Page 1 October 2013

Transcription:

ROCKWOOL Acoustic High performance sound deadening membrane for flat roofing and built-up metal roofs ROCKWOOL Acoustic is a flexible, high-density polymer mass layer. The product, when combined with ROCKWOOL insulation products, offers both high performance and economic acoustic solutions for flat roofing and built-up metal roofing systems (e.g. standing seam).

ROCKWOOL Acoustic An ideal acoustic solution from the ROCKWOOL SOUNDPRO range, for buildings requiring high levels of acoustic performance. These include schools, hospitals, cinemas, airports, concert halls, stadia, retail, leisure developments etc. Advantages Excellent acoustic properties Enhances low frequency performance Easy to cut and install on site Available as a roll less joints faster installation ROCKWOOL Acoustic. Increasing the SRI by just 3dB will approximately halve the transmitted sound using energy. 1.5mm PVC membrane mechanically fixed. HARDROCK Dual Density O.22mm polyethylene vapour control layer. Varying layers of ROCKWOOL Acoustic 5 (5kg/m2). O.70mm galvanised steel profile deck, 35mm deep. Fully tested system Cost effective Suitable for new build and refurbishment Flat Roofs - Roof Construction Constructions 1 to 6 indicate a Weighted Sound Reduction Index improvement of up to 12dB when Construction Options for Sound Reduction (based on above construction) To achieve 38dB Rw: 150mm HARDROCK DD with 1 layer of Acoustic To achieve 41dB Rw: 150mm HARDROCK DD with 2 layers of Acoustic 210mm HARDROCK DD with 1 layer of Acoustic To achieve 45dB Rw: 210mm HARDROCK DD with 2 layers of Acoustic To achieve 47dB Rw: 210mm HARDROCK DD with 4 layers of Acoustic Test Report Number Ctr Value C/03/7H/10161/L2 5 C/02/5L10526/1 Test 5 5-7C/06/5L13434/1 Test 6 6 C/06/5L13434/1 Test 3 6 C/06/5L13434/1 Test 4 6

ROCKWOOL Acoustic Built-up Metal Roofing For built-up metal roofing system applications (e.g. standing seam), ROCKWOOL Acoustic should be applied between the metal outer sheet and insulation. For enhanced performance, the membrane should also be positioned between the insulation layers as shown in construction 4. Construction 4 Sound Reduction Index values of up to 50dB. For assistance with such constructions, please contact ROCKWOOL Customer Support on 0871 222 1780. Rain noise Impact noise from rain can significantly increase the indoor noise level. Excessive noise from rain on metal roofs can result in noise radiating into working or habitable space below. Rain noise is therefore a potentially important noise source, which must be considered at an early point in the roof design in order to minimise disturbance within the building. The solution is provided by a combination of ROCKWOOL Acoustic (for damping of the profiled metal cladding) and ROCKWOOL insulation materials (for sound absorption). At the time of writing, a new laboratory test measurement standard for impact sound from rain on the roof, ISO 140-18 is under development. For assistance, please contact ROCKWOOL Customer Support on 0871 222 1780. Performance & Construction A typical construction is shown above comprising Aluminium outer sheet ROCKWOOL Cladding Roll ROCKWOOL Acoustic 5 (5kg/m2) 1 or 2 layers depending on acoustic requirements ROCKWOOL RW3 Slab Vapour Control Layer Steel liner tray In the absence of test data, ROCKWOOL Limited have assessed that similar constructions with combinations of ROCKWOOL Acoustic and Rockwool insulation materials are likely to achieve Weighted Acoustic Performance The addition of a mass layer is required in order to attain the highest acoustic performance levels for lightweight metal roof constructions. ROCKWOOL Acoustic offers additional mass whilst also providing inherent acoustic damping properties. Using ROCKWOOL Acoustic in conjunction with ROCKWOOL roofing products results in improved sound insulation levels across the frequency range. Testing has confirmed that ROCKWOOL Acoustic provides improved acoustic performance in comparison with heavier, and thicker Cementatious boards.

ROCKWOOL Acoustic Performance & Properties Two products are available. ROCKWOOL Acoustic 5 (5 Kg/m2) and ROCKWOOL Acoustic 10 (10 Kg/m2) ROCKWOOL Acoustic 5 Dimension: 6050 x 1220 x 2.6mm Weight: 5 kg/m2 Density: 1900 kg/m3 Supplied in rolls ROCKWOOL Acoustic 10 Dimensions: 2000 x 1000 x 5.2mm Weight: 10 kg/m2 Density: 1900 kg/m3 Supplied in sheets Resistance to moisture: ROCKWOOL Acoustic is water resistant. Tensile Strength: 30 N/cm2 (EN12311) Pliability: Does not break when bending at -20 C Elongation: 300% (EN12311) Thermal conductivity: 0.45 W/mK Installation flat roof constructions For flat roofing applications, ROCKWOOL Acoustic should be laid directly onto the metal decking, across the line of the profiles. The metal decking must be clean and dry. Align the membrane and extend the roll (or sheets) over the metal decking progressively. Please note that it is not necessary to remove the protective plastic film. All membrane joints should be overlapped by 50mm as small openings can reduce the level of acoustic insulation required. A Polythene VCL (should BS 5250:1989 calculations require installation) is applied, followed by the application of HARDROCK dual density roofing boards. A Mechanically fastened single ply membrane should then be installed in accordance with the manufacturers specification requirements. Day joints must be formed at the conclusion of each section of work to seal exposed edges of insulation boards and acoustic membrane. Installation of all components should be in accordance with BS6229:2003 (Code of practice for Flat Roofs with continuously supported coverings). coverage For a 35mm deep profiled metal deck, allow for yield of 1m2 of ROCKWOOL Acoustic to cover approximately 0.95m2 of surface area, including overlaps. Coverage may vary for other profile types. Cutting ROCKWOOL Acoustic is easily cut or shaped with a sharp knife. Storage and handling ROCKWOOL Acoustic 5 is available as individual rolls or as rolls on pallets. Weight per roll is approximately 37kg. ROCKWOOL Acoustic 10 is available in sheets on pallets. Weight per pallet is approximately 1800Kg. All products are wrapped in polythene for short-term protection, if stored outside. For longer-term protection, the product should be stored in dry premises, protected against weathering and must not be exposed to temperatures exceeding 35 C. For safety, pallets should not be stacked. Supply Available throughout the United Kingdom from ROCKWOOL stockists. A list is available on request.

ROCKWOOL Acoustic ROCKWOOL SOUNDPRO range of acoustic solutions ROCKWOOL Acoustic is a part of the ROCKWOOL SOUNDPRO range of acoustic solutions. Further information on the range is available from ROCKWOOL Customer Support on 0871 222 1780. Other acoustic applications ROCKWOOL Acoustic, due to its damping and sound reduction properties may be used for other applications requiring isolation or mass layers. For guidance in this respect, contact ROCKWOOL Customer Support. Sustainability As an environmentally conscious company, ROCKWOOL promotes the sustainable production and use of insulation and is committed to a continuous process of environmental improvement. All ROCKWOOL products provide outstanding thermal protection as well as four added benefits: Fire resistance Acoustic comfort Sustainable materials Durability Health and safety The safety of ROCKWOOL stone wool is confirmed by current UK and Republic of Ireland health & safety regulations and EU directive 97/69/EC: ROCKWOOL fibres are not classified as a possible human carcinogen. A Material Safety Data Sheet is available from ROCKWOOL Technical Support (0871 222 1780) and can be downloaded from www.rockwool.co.uk to assist in the preparation of risk assessments, as required by the Control of Substances Hazardous to Health Regulations (COSHH). Environment Relying on entrapped air for its thermal properties, we are proud to say that ROCKWOOL insulation does not contain (and has never contained) gases that have ozone depleting potential (ODP) or global warming potential (GWP). ROCKWOOL therefore complies with the relatively modest threshold of GWP<5 included in documents such as the Code for Sustainable Homes. ROCKWOOL is increasingly involved in recycling waste ROCKWOOL material that may be generated during installation or at end of life.we are happy to discuss the individual requirements of contractors and users considering returning Rockwool materials to our factory for recycling. More information: For further details visit our website at www.rockwool.co.uk or phone ROCKWOOL Technical Support on 0871 222 1780. Copyright ROCKWOOL April 2012 ROCKWOOL Limited Pencoed, Bridgend, CF35 6NY 26-28 Hammersmith Grove Hammersmith London W6 7HA info@rockwool.co.uk www.rockwool.co.uk ROCKWOOL Limited reserves the right to alter or amend the specification of products without notice as our policy is one of constant improvement. The information contained in this data sheet is believed to be correct at the date of publication. Whilst ROCKWOOL will endeavour to keep its publications up to date, readers will appreciate that between publications there may be pertinent changes in the law, or other developments affecting the accuracy of the information contained in this data sheet. The above applications do not necessarily represent an exhaustive list of applications for ROCKWOOL Acoustic. ROCKWOOL Limited does not accept responsibility for the consequences of using ROCKWOOL Acoustic in applications different from those described within this data sheet. Expert advice should be sought where such different applications are contemplated, or where the extent of any listed application is in doubt.