Mineral fibreglass insulation

Size: px
Start display at page:

Download "Mineral fibreglass insulation"

Transcription

1 Isover MULTIMAX 30 Specification code: MW - EN T5 - MU1 - WS - WL(P) - AF r 5 TeChNICaL SPeCIFICaTION Insulating slabs made of Isover fibreglass wool. The production method is based on the fibering of glass melt and other additives and ingredients. The mineral fibres produced are processed into the final slab shape on the production line. The entire fibre surface is hydrophobic. The slabs in the construction should be protected suitably against the weather effects (outer cassette sheathing, diffusion and vapour-proof foil). application A glass mineral wool slabs, Isover MULTIMAX are suitable for insulation of the outer walls of ventilated facade systems and are to be inserted into the grid under the cladding, or mechanically bonded into the multilayer masonry. The slabs can be mechanically bond using the clamps for soft MW insulations. Insulating slabs are not glued to the surface. When the material is used to insulate ceilings, it is also necessary to use metal dowel pins with respect to fire security that cannot be positioned at the edge of the slab. Especially the energy saving insulation type, λ D = 0,030 W.m -1.K -1. PaCkaGING, TRaNSPORT, WaRehOUSING A glass mineral wool slabs, Isover MULTIMAX, are packed into the PE foil with package height up to 0.5 m. The slabs have to be transported in covered vehicles under conditions preventing their wetting or other degradation. They should be stored flat in sheltered space to maximum layer height of 2 m. BeNeFITS dimensions and PaCkaGING Product (mm) Dimensions (mm) Per package (m2) MPS (m 2 ) TeChNICaL PaRameTeRS resistance R D (m 2. K. W -1 ) Isover MULTIMAX x Isover MULTIMAX x Isover MULTIMAX x Isover MULTIMAX x tolerance classification T5 complies with allowed tolerance according to EN 13162: -1% or - 1 mm and + 3 mm, while the higher numerical value prevails. conductivity coefficient λ D W. m -1. K EN Specific heat capacity c d J. kg -1. K ČSN Specific load value kn. m EN , EN 1990 Specific resistance against air flow AF r kpa. s. m EN Water vapour penetrability Vapour resistance coefficient (μ) MU EN ReLaTed documents EC compliance certificate 1486-CPD-0254

2 Isover UNIROL PROFI Specification code: MW - EN T2 - MU1 - AF 5 r Rolled insulation mats made of Isover fibreglass wool are covered with hydrophobic fibres on the entire surface. The production method is based on the fibering of glass melt and other additives and ingredients. The mineral fibres produced are processed into the final mat shape on the production line. The insulation in the construction should be protected (vapour-proof foil, suitable protection against dust setting in case of loosely laid insulation, additional construction layers). The insulation is not harmful to the environment or public health, it is resistant to moulds, fungi and wood-destroying insects. The fibreglass insulation mats with excellent heat-insulating properties are used as thermal and acoustic insulation of sloping roofs and ceilings. Superior energy saving type of insulation, λ D = W.m -1.K -1. The Isover rolls are strongly compressed within the package and wrapped with PE foil (1 MPS = 12 Rolls, volume 4,09 m 3 ). After unpacking, the rolls quickly acquire full thickness. Compressing makes manipulation easier and saves space in warehouses, during transport and on the construction site. Rolls have to be transported in covered vehicles under conditions preventing them from getting wet or being degraded. They are stored in covered spaces. Product (mm) Dimensions (mm) Per package (m 2 ) MPS (m 2 ) conductivity coefficient λ D W. m -1. K EN Specific load value kn. m EN , EN 1990 Maximum temperature for use C 200 Sound absorption coefficient α Hz resistance R D (m 2.K.W -1 ) Isover UNIROL PROFI x Isover UNIROL PROFI x Isover UNIROL PROFI x Isover UNIROL PROFI x Isover UNIROL PROFI x Isover UNIROL PROFI x Isover UNIROL PROFI x Isover UNIROL PROFI x tolerance classification T2 complies with the allowed tolerance according to EN 13162: -5% or -5 mm, while the higher numerical value prevails, and + 15% or + 15 mm where the lower tolerance numerical value is decisive. For calculation is possible use same value as for DOMO. Specific resistance against air flow AF r kpa. s. m -2 5 EN Water vapour penetrability Vapour resistance coefficient (μ) MU - 1 EN EG compliance certificate 1486-CPD-0254

3 Isover Multi-Komfort Passivhaus Klemmfilz Rolled insulation mats made of Isover fibreglass wool are covered with hydrophobic fibres on the entire surface. The production method is based on the fibering of glass melt and other additives and ingredients. The mineral fibres produced are processed into the final mat shape on the production line. The insulation in the construction should be protected (vapour-proof foil, suitable protection against dust setting in case of loosely laid insulation, additional construction layers). Isover MK-KF rolls are suitable for any thermal, acoustic, no-load insulation. Preferred application is for lattice works at multistoried or single storied buildings and their hanging false ceilings. Also everywhere where is recommended high thickens of thermal insulation to reach passive house level (ideal Multi-Comfort house level). conductivity coefficient λ D W. m -1. K EN Specific load value kn. m EN , EN 1990 Specification code: MW - EN T2 - MU1 - AF r5 The Isover MK-KF rolls are strongly compressed within the package and wrapped with PE foil. They come in MPS packs (1MPS = 18 rolls, volume 3,67 m 3 ). After unpacking, the rolls quickly acquire full thickness. Compressing makes manipulation easier and saves space in warehouses, during transport and on the construction site. Rolls have to be transported in covered vehicles under conditions preventing them from getting wet or being degraded. They are stored in covered spaces. Specific resistance against air flow AF r kpa. s. m -2 5 EN Water vapour penetrability Vapour resistance coefficient (μ) MU - 1 EN Product (mm) Dimensions (mm) Per package (m 2 ) MPS (m 2 ) resistance R D (m 2.K.W -1 ) Isover MK-KF x Isover MK-KF x Isover MK-KF x Isover MK-KF x Isover MK-KF x Isover MK-KF x Isover MK-KF * 3500 x Isover MK-KF * 3500 x Isover MK-KF * 3500 x Isover MK-KF * 3000 x tolerance classification T2 complies with the allowed tolerance according to EN 13162: -5% or -5 mm, while the higher numerical value prevails, and + 15% or + 15 mm where the lower tolerance numerical value is decisive. EG compliance certificate 1139-CPD-0735/09

4 Isover UNIROL-PLUS Specification code: MW - EN T2 - MU1 Rolled insulation mats made of Isover fibreglass wool are covered with hydrophobic fibres on the entire surface. The production method is based on the fibering of glass melt and other additives and ingredients. The mineral fibres produced are processed into the final mat shape on the production line. The insulation in the construction should be protected (vapour-proof foil, suitable protection against dust setting in case of loosely laid insulation, additional construction layers). The Isover UNIROL-PLUS rolls are strongly compressed within the package and wrapped with PE foil. They come in MPS packs (1MPS = 24 rolls for thicknesses mm and 12 rolls for thicknesses 180 and 200 mm, volume 4,09 m 3 ). After unpacking, the rolls quickly acquire full thickness. Compressing makes manipulation easier and saves space in warehouses, during transport and on the construction site. Rolls have to be transported in covered vehicles under conditions preventing them from getting wet or being degraded. They are stored in covered spaces. Isover UNIROL-PLUS rolls are suitable for unloaded thermal and acoustic insulation of pitch roofs especially with insertion between rafters and additional frame as well, into partition walls, wood ceilings insulations, false ceilings, and cavities. Technické parametry conductivity coefficient λ D W. m -1. K EN Specific load value kn. m EN , EN 1990 Ostatní vlastnosti Water vapour penetrability Vapour resistance coefficient (μ) MU - 1 EN Product (mm) Dimensions (mm) Per package (m 2 ) MPS (m 2 ) resistance R D (m 2.K.W -1 ) Isover UNIROL-PLUS x Isover UNIROL-PLUS x Isover UNIROL-PLUS x Isover UNIROL-PLUS x Isover UNIROL-PLUS x Isover UNIROL-PLUS x Isover UNIROL-PLUS x tolerance classification T2 complies with the allowed tolerance according to EN 13162: -5% or -5 mm, while the higher numerical value prevails, and + 15% or + 15 mm where the lower tolerance numerical value is decisive. EG compliance certificate 1486-CPD-0253

5 Isover UNI Mineral insulation from stone wool Specification code: MW - EN T4 - DS(T+) - MU1 Insulating slabs made of Isover mineral wool. The production is based on defibring method of the minerals composition melt and additional additives and ingredients. The mineral fibres produced are processed into the final slab shape on the production line. The entire fibre surface is hydrophobic. The slabs in the construction should be protected suitably against the weather effects (outer cassette sheathing, diffusion and vapour-proof foil). Isover UNI slabs are suitable for unloaded insulations of the outer walls (ventilated facades under the cladding with insulant inserted into cassettes or frames), insulation of the pitch roofs, ceilings, false ceilings and other light sandwich constructions. The material is suitable for fire protection partition walls where the density 40 kg.m -3 is required. EC compliance certificate 1390-CPD-0305/11/P Isover UNI insulation slabs are packed into the PE foil with package height up to 0.5 m. The slabs have to be transported in covered vehicles under conditions preventing their wetting or other degradation. They should be stored flat in sheltered space to maximum layer height of 2 m. Product (mm) Dimensions (mm) Per package (m 2 ) Isover UNI x Isover UNI x Isover UNI x Isover UNI x Isover UNI x Isover UNI x Isover UNI x Isover UNI x Isover UNI x Isover UNI x tolerance classification T4 complies with allowed tolerance according to EN 13162: -3% or - 3 mm, while the higher numerical value prevails and + 5% or + 5 mm where the lower tolerance numerical value is predominant. conductivity coefficient λ D W. m -1. K EN Specific heat capacity c d J. kg -1. K ČSN Specific load value kn. m EN , EN 1990 Dimensional stability at temperature (70 ± 2) C DS (T+) % 1 EN 1604 Melting temperature t t C 1000 DIN 4102 part 17 Frequency Hz The practical sound absorption coefficient α p according to EN ISO 354 and EN ISO Definition of single number value according to EN ISO mm mm mm mm Single number value - α w α stř NCR 40 mm 0.70 (MH) mm mm mm Moisture resistance factor (µ) MU - 1 EN Specific resistance against air flow AF r kpa. s. m EN 29053

6 Isover ORSIK Mineral insulation from stone wool Specification code: MW - EN T2 - MU1 Insulating slabs made of Isover mineral wool. The production is based on defibring method of the minerals composition melt and additional additives and ingredients. The mineral fibres produced are processed into the final slab shape on the production line. The entire fibre surface is hydrophobic. The slabs in the construction should be protected suitably against the weather effects, increased relative inner humidity and condensate (diffusion and vapour-proof foil). Isover ORSIK slabs are suitable for unloaded thermal, acoustic and fire insulation of pitch roofs especially with insertion between rafters and additional frame as well, into partition walls, wood ceilings insulations, false ceilings, and cavities. Isover ORSIK insulation slabs are packed into the PE foil with package height up to 0.5 m. The slabs have to be transported in covered vehicles under conditions preventing their wetting or other degradation. They should be stored flat in sheltered space to maximum layer height of 2 m. Product (mm) Dimensions (mm) Per package (m 2 ) Isover ORSIK x Isover ORSIK x Isover ORSIK x Isover ORSIK x Isover ORSIK * 1200 x Isover ORSIK * 1200 x Isover ORSIK * 1200 x Isover ORSIK * 1200 x Isover ORSIK * 1200 x Isover ORSIK * 1200 x tolerance classification T2 complies with allowed tolerance according to EN 13162: - 5% or - 5 mm, while the higher numerical value prevails and + 15% or + 15 mm where the lower tolerance numerical value is predominant. * Compressed packaging conductivity coefficient λ D W. m -1. K EN Specific heat capacity c d J. kg -1. K ČSN Tensile strength in slab level (σ t ) kpa 1 EN 1608 Specific load value kn. m -3 0,30 EN , EN 1990 Melting temperature t t C 1000 DIN 4102 part 17 Frequency Hz The practical sound absorption coefficient α p according to EN ISO 354 and EN ISO Definition of single number value according to EN ISO mm mm mm mm Single number value - α w α stř NCR 40 mm 0.70 (H) mm mm mm Moisture resistance factor (μ) MU - 1 EN EC compliance certificate 1390-CPD-0305/11/P

7 Isover DOMO COMFORT Specification code: MW - EN T2 - MU1 - AF r 5 Rolled insulation mats made of Isover fibreglass wool 1200 mm width with special coated surface for easy workability. The wool are covered with hydrophobic fibres on the entire surface. The production method is based on the fibering of glass melt and other additives and ingredients. The mineral fibres produced are processed into the final mat shape on the production line. The insulation in the construction should be protected (vapour-proof foil, suitable protection against dust setting in case of loosely laid insulation, additional construction layers). The insulation is not harmful to the environment or public health, it is resistant to moulds, fungi and wood-destroying insects. Isover DOMO COMFORT rolls are suitable for any thermal, acoustic, no-load insulation for hanging false ceilings, cavity insulation (increase in acoustic insulation), and non-running roof constructions. The Isover DOMO COMFORT rolls are packaged into PE foil. They come in MPS packs (1MPS = 24 rolls, volume 4.09 m 3 ). Loose packages can be supplied after an agreement with the manufacturer. Rolls have to be transported in covered vehicles under conditions preventing them from getting wet or being degraded. They are stored in covered spaces. Product (mm) Dimensions (mm) Per package (m 2 ) MPS (m 2 ) resistance R D (m 2.K.W -1 ) DOMO COMFORT x DOMO COMFORT x DOMO COMFORT x DOMO COMFORT x DOMO COMFORT x tolerance classification T2 complies with allowed tolerance according to EN 13162: - 5% or - 5% mm, while the higher numerical value prevails and + 15mm or + mm where the lower tolerance numerical value is predominant. conductivity coefficient λ D W. m -1. K EN Specific load value kn. m EN , EN 1990 Reaction to fire class - A2-s1,d0 EN Specific resistance against air flow AF r kpa. s. m -3 5 EN Vapour resistance coefficient (μ) MU - 1 EN EC compliance certificate 1486-CPD-0254

8 Isover DOMO Specification code: MW - EN T1 - MU1 - AF r 5 Insulation rolls made of Isover fibreglass wool. The production is based on defibration of melt of glass and other additives and ingredients. Produced mineral fibres are then shaped into rolls on the production line. Fibres are made water-repellent on their entire surface. Insulation in construction have to be protected suitably (steam protection foil, suitable protection against dust settling in loosely laid constructions, other construction layers). Isover DOMO rolls are suitable for any thermal, acoustic, no-load insulation for hanging false ceilings, cavity insulation (increase in acoustic insulation), and non-running roof constructions. conductivity coefficient λ D W. m -1. K EN Specific load value kn. m EN , EN 1990 Frekvence Hz DOMO Directly on the wall Acoustic absorption coefficient α DOMO mm The Isover DOMO rolls are packaged into PE foil. They come in MPS packs (1MPS = 24 rolls, volume 4,09 m 3 ). Loose packages can be supplied after an agreement with the manufacturer. Rolls have to be transported in covered vehicles under conditions preventing them from getting wet or being degraded. They are stored in covered spaces. DOMO DOMO Specific resistance against air flow AF r kpa. s. m -2 5 EN Water vapour penetrability Vapour resistance coefficient (μ) MU - 1 EN Product (mm) Dimensions (mm) Per package (m 2 ) MPS (m 2 ) resistance R D (m 2.K.W -1 ) Isover DOMO TWIN 10/5 100/50 2 x 7500 x Isover DOMO TWIN 12/6 120/60 2 x 6000 x Isover DOMO x Isover DOMO x Isover DOMO x Isover DOMO x Isover DOMO x Isover DOMO x Isover DOMO x tolerance classification T1 complies with the allowed tolerance according to EN 13162: -5% or -5 mm, while the higher numerical value prevails, and higher thickness is possible. Note: Name TWIN 10/5 - in the packing are 2 rolls, same thickness 50 mm, applicable as one roll 100 mm. EG compliance certificate 1486-CPD-0254

9 Isover ORSTROP Mineral insulation from stone wool Specification code: MW - EN T2 - MU1 Insulating slabs made of Isover mineral wool. The production is based on defibring method of the minerals composition melt and additional additives and ingredients. The mineral fibres produced are processed into the final slab shape on the production line. The entire fibre surface is hydrophobic. The slabs in the construction should be protected suitably against inner humidity (vapour-proof foil, suitable protection against dust setting, false ceilings sheathing, and additional construction layers). Isover ORSTROP slabs are suitable for unloaded thermal, acoustic and fire insulation of ceilings (between joists), unused attics, false ceilings and cavities. EC compliance certificate 1390-CPD-0305/11/P Isover ORSTROP insulation slabs are packed into the PE foil with package height up to 0.5 m. The slabs have to be transported in covered vehicles under conditions preventing their wetting or other degradation. They should be stored flat in sheltered space to maximum layer height of 2 m. Product (mm) Dimensions (mm) Per package (m 2 ) Isover ORSTROP x Isover ORSTROP x Isover ORSTROP x Isover ORSTROP x Isover ORSTROP * 1200 x Isover ORSTROP * 1200 x Isover ORSTROP * 1200 x Isover ORSTROP * 1200 x Isover ORSTROP * 1200 x Isover ORSTROP * 1200 x tolerance classification T2 complies with allowed tolerance according to EN 13162: - 5% or - 5% mm, while the higher numerical value prevails and + 15mm or + mm where the lower tolerance numerical value is predominant. * Compressed packaging conductivity coefficient λ D W. m -1. K EN Specific heat capacity c d J. kg -1. K ČSN Specific load value kn. m EN , EN 1990 Melting temperature t t C 1000 DIN 4102 part 17 Frequency Hz Acoustic absorption coefficient 40 mm α for perpendicular impact of 60 mm acoustic waves (-) according to 80 mm ISO mm mm mm 0.55 Mean acoustic absorption 60 mm 0.68 coefficient in the band of mm 0.88 ISO Hz α stř 120 mm mm 0.96 Moisture resistance factor (µ) MU - 1 EN 12086

10 Isover AKU Mineral insulation from stone wool Specification code: MW - EN T4 - DS(T+) - MU1 Insulating slabs made of Isover mineral wool. The production is based on defibring method of the minerals composition melt and additional additives and ingredients. The mineral fibres produced are processed into the final slab shape on the production line. The entire fibre surface is hydrophobic. The slabs in the construction should be protected suitably against the weather effects (outer cassette sheathing, diffusion and vapour-proof foil). Isover UNI slabs are suitable for plasterboard wall systems with 625 mm spacing as an acoustic and thermal insulation. The material is suitable for fire protection partition walls where the density 40 kg.m -3 is required. EC compliance certificate 1390-CPD-0305/11/P Isover UNI insulation slabs are packed into the PE foil with package height up to 0.5 m. The slabs have to be transported in covered vehicles under conditions preventing their wetting or other degradation. They should be stored flat in sheltered space to maximum layer height of 2 m. Product (mm) Dimensions (mm) Per package (m 2 ) Isover AKU x Isover AKU x Isover AKU x Isover AKU x Isover AKU x tolerance classification T4 complies with allowed tolerance according to EN 13162: -3% or - 3 mm, while the higher numerical value prevails and + 5% or + 5 mm where the lower tolerance numerical value is predominant. conductivity coefficient λ D W. m -1. K EN Specific heat capacity c d J. kg -1. K ČSN Dimensional stability at temperature (70 ± 2) C DS (T+) % 1 EN 1604 Specific load value kn. m EN , EN 1990 Melting temperature t t C 1000 DIN 4102 part 17 Frequency Hz The practical sound absorption coefficient α p according to EN ISO 354 and EN ISO Definition of single number value according to EN ISO mm mm mm mm Single number value - α w α stř NCR 40 mm 0.70 (MH) mm mm mm Other properties Specific resistance against air flow AF r kpa. s. m EN Moisture resistance factor (µ) MU - 1 EN 12086

11 Isover PIANO Specification code: MW - EN T2 - MU1 - AF r 5 Insulation rolls made of Isover fibreglass wool. The production is based on defibration of melt of glass and other additives and ingredients. Produced mineral fibres are then shaped into rolls on the production line. Fibres are made water-repellent on their entire surface. Rolls in construction have to be protected suitably (steam protection foil, partition wall lining, other layers of construction). ISOVER PIANO rolls are suitable for thermal, acoustic, no-load insulation which are a part of light construction with metal reinforcement. In residential or administrative buildings, attics, hotels, hospitals, and industry premises, the PIANO rolls increase total acoustic absorption of construction and therefore acoustic insulation capacity (improvement in sound reduction of up to 18dB, according to solution for side ways noise travel and the number of holes in the construction), especially if the entire cavity is filled (5-7 db improvement in sound reduction from cavity only half filled). The improvement in sound reduction depends on how side ways noise travel is limited, i.e. how the carrying frame of partition walls is insulated from the floor, ceiling, and walls with a flexible insulation tape. EG compliance certificate 1139-CPD-0170/02 Product (mm) Dimensions (mm) Packaging (m 2 ) MPS (m 2 ) The Isover PIANO rolls are packaged into PE foil. They come in MPS packs (1MPS = 24 rolls, volume 4.09 m 3 ). Loose packages can be supplied after an agreement with the manufacturer. Rolls have to be transported in covered vehicles under conditions preventing them from getting wet or being degraded. They are stored in covered spaces. resistance R D (m 2.K.W -1 ) Isover PIANO TWIN 8/ x x Isover PIANO TWIN 10/ x x Isover PIANO TWIN 12/ x x tolerance classification T2 complies with allowed tolerance according to EN 13162: - 5% or - 5mm, while the higher numerical value prevails and + 15% or +15 mm where the lower tolerance numerical value is predominant. Note: Name TWIN 10/5 - in the packing are 2 rolls, same thickness 50 mm, applicable as one roll 100 mm. Parameter Jednotka Hodnota Norma conductivity coefficient λ D W. m -1. K EN Specific heat capacity c d J. kg -1. K ČSN Specific load value kn. m EN EN 1990 Melting temperature t t C 1000 DIN 4102 part 17 Frequency Hz The practical sound absorption coefficient α p according to EN ISO 354 and EN ISO Definition of single number value according to EN ISO mm mm mm mm Single number value - α w α stř NCR 40 mm 0.75 (H) mm mm mm Specific resistance against air flow AF r kpa. s. m -2 5 EN Water vapour penetrability Vapour resistance coefficient (μ) MU - 1 EN 12086

12 Isover ROLLINO Specification code: MW - EN T2 - MU1 - AF r 5 Insulation rolls made of Isover fibreglass wool. The production is based on defibration of melt of glass and other additives and ingredients. Produced mineral fibres are then shaped into rolls on the production line. Fibres are made water-repellent on their entire surface. Rolls in construction have to be protected suitably (steam protection foil, diffusion foil, suitable protection from dust settling, lining of false ceilings, sheathing of facades, other layers of construction). Isover ROLLINO slabs in a roll are suitable for thermal, acoustic, no-load insulation in attic apartment constructions, between rafters and stretchers, into ceilings, hanging false ceilings, for insulation of partition walls, cavities and ventilated facades with a frame and two storeys maximum, into assembled floors with posts. Isover MERINO slabs have dimensions of 625 x 1200 mm, are flexible, have stable form, and are applied on paper base. Isover ROLLINO is then rolled together with the paper base which has to be removed prior use. EG compliance certificate 1139-CPD-0735/09 The Isover ROLLINO slabs are packaged with the paper base into 1200mm rolls wrapped with PE foil. They are compressed within the package which makes manipulation easier and saves space in warehouses, during transport and on the construction site. Compared to MERINO, the space savings are up to three times higher. After unpacking, the slabs quickly acquire full thickness. The rolls come in MPS packs (1MPS = 18 rolls, volume 4,09 m 3 ). Rolls have to be transported in covered vehicles under conditions preventing them from getting wet or being degraded. They are stored in covered spaces. Product (mm) Dimensions (mm) Packaging (m 2 ) Packaging (m 3 ) MPS (m 2 ) Isover ROLLINO x Isover ROLLINO x Isover ROLLINO x Isover ROLLINO x Isover ROLLINO x Isover ROLLINO x Isover ROLLINO x tolerance classification T2 complies with allowed tolerance according to EN 13162: - 5% or - 5mm, while the higher numerical value prevails and + 15% or +15 mm where the lower tolerance numerical value is predominant. Condition set for declared values I(10 C) and (u dry ) - - ČSN EN ISO conductivity coefficient λ D W. m -1. K ČSN EN Specific load value kn. m ČSN EN ČSN EN 1990 Reaction to fire class - A1 ČSN EN Frequency Hz ROLLINO 2-0,10 0,35 0,60 0,75 0,90 0,90 ROLLINO 5-0,25 0,60 0,90 1,00 1,00 1,00 60 mm Acoustic absorption coefficient α ROLLINO 8-0,45 0,75 1,00 1,00 1,00 1,00 ROLLINO 2-0,20 0,55 0,85 0,85 0,90 0,90 ROLLINO 5-0,40 0,75 1,00 1,00 1,00 1, mm ROLLINO 8-0,65 1,00 1,00 1,00 1,00 1,00 Specific resistance against air flow AF r kpa. s. m -2 5 ČSN EN Water vapour penetrability Vapour resistance coefficient (μ) MU - 1 ČSN EN 12086

13 Isover MERINO Specification code: MW - EN T2 - MU1 - AF r 5 Insulation slabs made of Isover fibreglass wool. The production is based on defibration of melt of glass and other additives and ingredients. Produced mineral fibres are then shaped into slabs on the production line. Fibres are made water-repellent on their entire surface. Slabs in construction have to be protected suitably (steam protection foil, protection from dust settling, other layers of construction). Isover MERINO slabs are flexible and have stable shape but cannot be bear load. They are suitable for any thermal, acoustic, no-load insulation, especially for double construction, ceiling fillings, hanging false ceilings, and cavities (improving the acoustic absorption of the construction, assembled floors with posts), for ventilated facades with frame insulation (maximum two storeys, using timber studs with 300 mm clearance). EG compliance certificate 1486-CPD-0254 Isover MERINO slabs are packaged into PE foil. They come in MPS packs (1MPS = 12 packages). Loose packages can be supplied after an agreement with the manufacturer. Slabs have to be transported in covered vehicles under conditions preventing them from getting wet or being degraded. They are stored in covered spaces. Product (mm) Dimensions (mm) Packaging (m 2 ) Packaging (m 3 ) MPS (m 2 ) Isover MERINO x Isover MERINO x Isover MERINO x Isover MERINO x Isover MERINO x Isover MERINO x Isover MERINO x tolerance classification T2 complies with allowed tolerance according to EN 13162: - 5% or - 5 mm, while the higher numerical value prevails and + 15% or +15 mm where the lower tolerance numerical value is predominant. Condition set for declared values I(10 C) and (u dry ) - - ČSN EN ISO conductivity coefficient λ D W. m -1. K ČSN EN Specific load value kn. m ČSN EN ČSN EN 1990 Reaction to fire class - A1 ČSN EN Frequency Hz MERINO 2-0,10 0,35 0,60 0,75 0,90 0,90 MERINO 5-0,25 0,60 0,90 1,00 1,00 1,00 60 mm Acoustic absorption coefficient α MERINO 8-0,45 0,75 1,00 1,00 1,00 1,00 MERINO 2-0,20 0,55 0,85 0,85 0,90 0,90 MERINO 5-0,40 0,75 1,00 1,00 1,00 1, mm MERINO 8-0,65 1,00 1,00 1,00 1,00 1,00 Specific resistance against air flow AF r kpa. s. m -2 5 ČSN EN Water vapour penetrability Vapour resistance coefficient (μ) MU - 1 ČSN EN 12086

14 Isover ORSET Mineral insulation from stone wool Specification code: MW - EN T2 - MU1 Insulating slabs made of Isover mineral wool. The production is based on defibring method of the minerals composition melt and additional additives and ingredients. The mineral fibres produced are processed into the final slab shape on the production line. The entire fibre surface is hydrophobic. The slabs in the construction should be protected suitably (diffusion and vapour-proof foil against the weather effects, increased inner humidity, and outer partition wall sheathing). Isover ORSET slabs are suitable especially for unloaded thermal, acoustic and fire insulation of partition walls and other constructions of slanting roofs with insertion between rafters with clearance up to 1m, under additional frames of false ceilings (625mm), ceilings insulation, false ceilings, and cavities. EC compliance certificate 1390-CPD-0305/11/P Isover ORSET insulation slabs are packed into the PE foil with package height up to 0.5 m. The slabs have to be transported in covered vehicles under conditions preventing their wetting or other degradation. They should be stored flat in sheltered space to maximum layer height of 2 m. Product (mm) Dimensions (mm) Per package (m 2 ) Isover ORSET x Isover ORSET x Isover ORSET x Isover ORSET x Isover ORSET x Isover ORSET x Isover ORSET x Isover ORSET x Isover ORSET x Isover ORSET x Isover ORSET x tolerance classification T2 complies with allowed tolerance according to EN 13162: - 5% or - 5% mm, while the higher numerical value prevails and + 15mm or + mm where the lower tolerance numerical value is predominant. Parameter Jednotka Hodnota Norma Soubor podmínek pro deklarované hodnoty I(10 C) a (u dry ) - - EN ISO Condition set for declared values I(10 C) and (u dry ) W. m -1. K EN Specific heat capacity c d J. kg -1. K ČSN Specific load value kn. m EN EN 1990 Melting temperature t t C 1000 DIN 4102 part 17 Frequency Hz The practical sound absorption coefficient α p according to EN ISO 354 and EN ISO Definition of single number value according to EN ISO mm mm mm mm Single number value - α w α stř NCR 40 mm 0.70 (H) mm mm mm Moisture resistace factor (µ) MU - 1 EN 12086

15 AKUSTIK PLATTE Specification code: MW EN T4 - MU1 - AF r 5 Insulation slabs made of Isover fibreglass wool. The production is based on defibration of melt of glass and other additives and ingredients. Produced mineral fibres are then shaped into slabs on the production line. Fibres are made water-repellent on their entire surface. Slabs in construction have to be protected suitably (covered with perforated material, other layers of construction). Isover AKUSTIK PLATTE slabs are suitable for any thermal, acoustic, no-load insulation. Black glass non-woven fabric is attached to one side. The slabs are used especially as absorbing insertion in lining elements for acoustic walls, ceilings, false ceilings, and thermal and acoustic insulation of air-conditioning devices. They are suitable for airflow not exceeding 30m/s. Fibers are made water-repellent on their entire surface. Isover AKUSTIK PLATTE slabs are packaged into PE foil. Slabs have to be transported in covered vehicles under conditions preventing them from getting wet or being degraded. They are stored in covered spaces. Product (mm) Dimensions (mm) Packaging (m 2 ) AKUSTIK PLATTE x AKUSTIK PLATTE x AKUSTIK PLATTE x AKUSTIK PLATTE x tolerance classification T4 complies with allowed tolerance according to EN 13162: -3% or - 3 mm, while the higher numerical value prevails and + 5% or + 5 mm where the lower tolerance numerical value is predominant. conductivity coefficient λ D W. m -1. K EN Specific load value kn. m EN , EN 1990 Reaction to fire class - A2 - s1, d0 EN Frequency Hz AKUSTIK PLATTE directly on the wall AKUSTIK PLATTE Acoustic absorption coefficient α 60 mm AKUSTIK PLATTE mm AKUSTIK PLATTE mm AKUSTIK PLATTE Specific resistance against air flow AF r kpa. s. m -2 5 EN Water vapour penetrability Vapour resistance coefficient (μ) MU - 1 EN EC certificate 1139-CPD-0735/09

Rockwool Cladding Roll

Rockwool Cladding Roll Rockwool Cladding Roll High performance industrial insulation has been specifically developed for use in lightweight cladding applications to commercial or industrial framed buildings. Cladding Roll U/F

More information

Rockwool Flexi Insulation Application Guide

Rockwool Flexi Insulation Application Guide Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed

More information

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS

More information

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available. APR 1200 Acoustic Partition Roll CI/Sfb Ref: APR002 Glass mineral wool roll designed to provide high levels of sound insulation in walls and floors to meet Part E (England & Wales) and Section 5 (Scotland)

More information

Authorised and notified according to Article 10 of the Council Directive 89/106/EEC of 21 December 1988 on the

Authorised and notified according to Article 10 of the Council Directive 89/106/EEC of 21 December 1988 on the ÖSTERREICHISCHES I N S T I T U T F Ü R B A U T E C H N I K A-1010 Vienna, Schenkenstrasse 4 Tel.: + 4 3 ( 0 ) 1-5 3 3 6 5 5 0 Fax: + 4 3 ( 0 ) 1-5 3 3 6 4 2 3 relating to construction products E - m a

More information

European Technical Approval ETA 13/0526

European Technical Approval ETA 13/0526 European Technical Approval ETA 13/0526 Trade Name Holder of the approval Website Generic type and use of construction product DOLCEA i3 PCIM S.A. Rue du Péquet 54 5590 Achene (Ciney) Belgium www.isoproc.eu

More information

European technical approval

European technical approval Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating

More information

FIBRANgeo. Stonewool thermal insulation, sound insulation and fire protection products for building applications

FIBRANgeo. Stonewool thermal insulation, sound insulation and fire protection products for building applications 00 product catalogue Stonewool thermal insulation, sound insulation and fire protection products for building applications stonewool building insulation Manufacturing of stonewool products are industrially

More information

Multi-layer Insulation Blanket for Roofs

Multi-layer Insulation Blanket for Roofs Multilayer Insulation Blanket for Roofs Thermal Insulation in a 40mm thin, flexible, multilayer membrane Meets requirements of L1A, L1B 2010 In accordance with BR443 NHBC Acceptance Pitched & Flat roof

More information

ProRox Slabs (formerly known as RW slabs)

ProRox Slabs (formerly known as RW slabs) Slabs (formerly known as RW slabs) Versatile thermal acoustic insulation slabs ROCKWOOL's Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation. They are

More information

Composite Panel Firewall Systems

Composite Panel Firewall Systems Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.

More information

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory

More information

Twiga Insul. India's Leading Thermal and Acoustic Insulation. Insulating India

Twiga Insul. India's Leading Thermal and Acoustic Insulation. Insulating India Twiga Insul India's Leading Thermal and Acoustic Insulation Insulating India Insulating India Twiga is the leading manufacturer of glass wool insulation in India, with a twenty-five year track record of

More information

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01 Section Built-up Metal Roofs Rail and bracket system Product: Earthwool FactoryClad range Bu01 Standing seam system Product: Earthwool FactoryClad range and Earthwool Universal Slab Bu02 Built-up Metal

More information

We care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview

We care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview http://upload.wikimedia.org/wikipedia/commons/a/ae/flag_of_the_united_kingdom.svg.0.0 :8 Seite von Environmentally-Friendly Building Products from Renewable Resources Product range overview We care about

More information

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation. Rigid, Semirigid and Flexible Slabs Versatile thermal acoustic insulation slabs ROCKWOOL are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation. They are manufactured

More information

Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: sales@durasystems.com. The Passive Fire Protection Specialists

Enclosures 1-866-338-0988. DuraSystems Barriers, Inc. www.durasystems.com Email: sales@durasystems.com. The Passive Fire Protection Specialists Enclosures Sturdy single and double wall fire protection construction Impact resistant Fast & easy installation Pre-manufactured and modular Available in galvanized, stainless steel & other specialty metals

More information

Stonewool Insulation for Thermal, Acoustic and Fire Safety Building Applications

Stonewool Insulation for Thermal, Acoustic and Fire Safety Building Applications Stonewool Insulation for Thermal, Acoustic and Fire Safety Building Applications www.kimmcoinsulation.com Our Insulation Business As the market leader in the GCC, Turkey and India, the Insulation Group

More information

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,

More information

How To Make An Oriented Strand Board

How To Make An Oriented Strand Board ABOUT COMPANY Mission Provide solutions to enchance customers product value. Vision - To be a leader among wood based panel producers in the region. Values Innovation, integrity and team commitment. BOLDERAJA

More information

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW Insulated Roof & Wall Panels Trapezoidal Insulated Roof Panels KS1000 RW Overview Kingspan roof panel systems present a superior system compared to conventional multi-part site assembled systems. They

More information

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope STEEL BUILDINGS IN EUROPE Single-Storey Steel Buildings Part 8: Building Envelope Single-Storey Steel Buildings Part 8: Building Envelope 2 - ii Part 8: Building Envelope emissions

More information

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining

Section 3.1.2. Timber Frame Walls. Single layer between studs. Single layer between studs with service void. Between studs with insulated lining Section Timber Frame Walls Single layer between studs Product: Earthwool FrameTherm Rolls and Slabs Tf01 Single layer between studs with service void Product: Earthwool FrameTherm Rolls and Slabs Tf02

More information

European Organisation for Technical Approvals

European Organisation for Technical Approvals Warrington Certification Limited, Holmesfield Road, Warrington, WA1 2DS Tel. +44 (0) 1925-646777 Fax +44 (0) 1925-646667 Member of EOTA Authorised and notified according to Article 10 of the Council Directive

More information

Annex of the certificate (Page 1/6) Accreditation Scope

Annex of the certificate (Page 1/6) Accreditation Scope As a Testing Laboratory Annex of the certificate (Page 1/6) Accreditation Scope Address: Küçük Çiğli Mh. 8780/1 Sk. No:5 Çiğli 35681 İZMİR / TÜRKİYE Phone : 0 232 376 24 25 Fax : 0 232 386 33 98 E-Mail

More information

Edition: Export Published: 09/2010. Product catalogue. Technical and industrial insulation. Lapinus

Edition: Export Published: 09/2010. Product catalogue. Technical and industrial insulation. Lapinus Edition: Export Published: 09/2010 Product catalogue Technical and industrial insulation by by RTI, excellence in fi resafe solutions Rockwool Technical Insulation (RTI) - an independent organisation within

More information

SmartPly OSB3 SMARTPLY

SmartPly OSB3 SMARTPLY SMARTPLY SmartPly OSB3 SmartPly OSB3 is a highly engineered, moisture resistant load-bearing panel designed for use in humid conditions and is therefore ideal for many structural and non-structural applications

More information

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas

FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas FERMACELL Powerpanel H 2 O for Wet & Moisture affected areas Powerpanel H 2 O is a cement based board from FERMACELL. Board Characteristics Board Thickness 12.5 mm Board Sizes 1000 x 1200 mm 50 sheets/pallet

More information

sound reduction systems for commercial, educational and industrial environments

sound reduction systems for commercial, educational and industrial environments sound reduction systems for commercial, educational and industrial environments Tel: +44 ()14 3874 Fax: +44 ()14 38957 E-mail: info@soundreduction.co.uk Web: www.soundreduction.co.uk soundblocker Acoustic

More information

AND MEMBRANES ROOFING UNDERLAYS. www.fakro.com

AND MEMBRANES ROOFING UNDERLAYS. www.fakro.com AND MEMBRANES 010 ROOFING UNDERLAYS 1 HO DOES YOUR ROOF BREATHe? MEMBRANES THE WAY to A WARM AND DRY ROOF HO HO HO HO HO HO WATERTIGHTNESS The FAKRO Company offers a wide range of membranes and underlays

More information

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors Roxul Safe n Sound Sound Control and Fire Safety From One Batt Insulation Roxul

More information

ROCK WOOL Preformed Pipe Section

ROCK WOOL Preformed Pipe Section ROCK WOOL Preformed Pipe Section Rockwool preformed Pipe section conforming ASTM C 547 and equivalent BS39584 is intended for the thermoacoustic insulation and fire protection of pipe works operating at

More information

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability 1/9/13 By Brett T. Fagan, P.E. Presented by Marie Horan, P.E. Building Diagnostics, Inc. Building Diagnostics Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

More information

Dubai Municipality Standard DMS 1: Part 5: 2004

Dubai Municipality Standard DMS 1: Part 5: 2004 Specification for precast concrete blocks Part 5: Normal-weight concrete-polystyrene sandwich masonry blocks Issue Date Revision Revision Description Prepared by Approved by Authorized by 19/12/2004 Issue

More information

Understanding BS EN 771-3: Aggregate concrete masonry units

Understanding BS EN 771-3: Aggregate concrete masonry units 60 Charles Street, Leicester LE1 1FB Tel: 0116 253 6161 Fax: 0116 251 4568 Email: enquiries@cba-blocks.org.uk Website: www.cba-blocks.org.uk February 2006 Understanding BS EN 771-3: Aggregate concrete

More information

Airtight Intelligence

Airtight Intelligence VARIO - Airtight Intelligence The multitasking membrane The Vario System keeps heat in Airtight Intelligence Vario-System keeps draughts out beats present and future regulations saves energy Introducing

More information

Fiberglas, Exterior Wall Thermal Insulation

Fiberglas, Exterior Wall Thermal Insulation PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

Master Panel 1000 W Wall

Master Panel 1000 W Wall Master Panel 1000 W Wall Product Description In order to generate an aesthethic outlook wall panels are generally produced as micro hedge. Besides, in connection points concealed screw is used which provides

More information

Squash Court Design general points

Squash Court Design general points Squash Court Design general points Contents: Contents:... 1 1. Squash Court Dimensions... 2 2. CourtTech Walls... 3 3. Dimensional requirements for courts with CourtTech Walls... 3 4. Loading of CT System

More information

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render BEST PRACTICE GUIDE Fibrelime Premixed Universal Plaster and Render Contents: Fibrelime description Fibrelime suitability Preparation before application Application Aftercare Painting General Recommended

More information

Asphalt Shingle Application Requirements

Asphalt Shingle Application Requirements Alberta Allied Roofing Association Asphalt Shingle Application Requirements Section 1 Roof Decks 1.1 General Asphalt Shingles are not permitted to be installed directly over rigid insulation. When Asphalt

More information

EcoTouch Insulation with PureFiber Technology

EcoTouch Insulation with PureFiber Technology PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.

More information

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet

More information

Master Panel 1000 R5 Roof

Master Panel 1000 R5 Roof Master Panel 1000 R5 Roof Product Description The important feature of the roof elements are the easy installation procedure. The element fix exactly and pushed together without much force. Roof coverage

More information

BETONYP building boards. The modern way of living.

BETONYP building boards. The modern way of living. BETONYP building boards The modern way of living. Tough for 30 years. Healthy, debarked pine wood and cement: the raw materials used to produce one of our most successful products for more than three decades.

More information

Modular Access Floor for Data Center. From Rack to Row to Room to Building

Modular Access Floor for Data Center. From Rack to Row to Room to Building Modular Access Floor for Data Center From Rack to Row to Room to Building Why using Scneider Electric modular access floor in Data Centers The evolution of modern Data Centers emphasizes specific exigencies

More information

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight

More information

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY PERFORMANCE CEILINGS M ore s c op e f or i n n ovat i on AMF Line; wall absorbers Wall mounted acoustic designs MADE IN GERMANY 138568_Prospekt Wandabsorber_GB int.indd 1 Acoustic elements on the wall

More information

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings BUILDING ENVELOPE DESIGN BY ROXUL Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB Exterior

More information

Marine & Offshore Insulation. - products and constructions November 2009

Marine & Offshore Insulation. - products and constructions November 2009 Marine & Offshore Insulation - products and constructions November 2009 Marine and offshore insulation worldwide For many years ROCKWOOL Marine & Offshore has been one of the leading suppliers marine and

More information

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors. Fire & Soundproofing Insulation Roxul SAFE N SOUND Fire and Soundproofing Insulation for Interior Partition Walls and Floors. Roxul SAFE N SOUND Sound control and fire safety from one batt Insulation.

More information

Roxul Board Insulation Section 07 21 13 Master Guide Specification (CAVITYROCK DD) Page 1 October 2013

Roxul Board Insulation Section 07 21 13 Master Guide Specification (CAVITYROCK DD) Page 1 October 2013 Master Guide Specification (CAVITYROCK DD) Page 1 ROXUL GUIDE NOTE: This master specification section is based on ROXUL INC., CAVITYROCK DD. Standard application: Cavity wall. ROXUL GUIDE NOTE: This master

More information

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit R-H-DI1 INSULATION BATT NR-E-IB1 Avoid Using Batt Insulation With Metal Framing Batt insulation should not be used with metal framing systems. Although it is common to see fiberglass batt insulation installed

More information

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and

More information

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings Building Envelope Design using ROXUL Building Envelope Design using ROXUL (BEDR ) FIREWALL and ROXUL PLUS MB Fire Rated Board Insulation for Pre-Engineered Metal Buildings ROXUL FIREWALL & ROXUL PLUS MB

More information

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings INSULATION FOR PRE-ENGINEERED METAL BUILDINGS ROXUL SAFE 55 & 65 and ROXUL PLUS MB Insulation for Pre-Engineered Metal Buildings ROXUL SAFE AND ROXUL PLUS MB Exterior Wall Insulation for Pre-Engineered

More information

Steel-framed Walls. Insulation

Steel-framed Walls. Insulation Insulation A4/8 SF AW1192 Issue 4 Nov 2012 Steel-framed Walls Insulation guide Helps achieve a 6-star house energy rating Rigid and flexible Kingspan AIR-CELL solutions available Vapour barrier or vapourpermeable

More information

Page 1 of European Technical Approval ETA-08/0018

Page 1 of European Technical Approval ETA-08/0018 Page 1 of European Technical Approval ETA-08/0018 VTT Expert Services Oy PL 1001 02044 VTT Puh. +358 20 722 4911 Telekopio +358 20 722 7003 Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston

More information

Post-insulation of cellar ceiling and cellar walls

Post-insulation of cellar ceiling and cellar walls WP5 Education and Economic Promotion Post-insulation of cellar ceiling and cellar walls Educational product: New lecture material for training modules dealing with knowledge and skills how to apply suitable

More information

The Pocket Guide To Insulation August 2013

The Pocket Guide To Insulation August 2013 The Pocket Guide To Insulation August 2013 Introduction Knauf Insulation is the UK s leading manufacturer of insulation products, including: Earthwool glass and rock mineral wool Polyfoam ECO extruded

More information

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests Product Data Sheet Edition 05/12/2014 Identification no: 020204030010000044 Sikadur -41 CF Rapid 3-part thixotropic epoxy patching mortar Construction Product Description Uses Characteristics / Advantages

More information

UniPlate. Solar Collectors SOLAR SYSTEMS. www.solarico.eu

UniPlate. Solar Collectors SOLAR SYSTEMS. www.solarico.eu UniPlate Solar Collectors SOLAR SYSTEMS www.solarico.eu keep the sun in mind Solar energy has by far the highest theoretical potential of the earth s renewable energy sources. It is the most abundant energy

More information

HEALTHY LIVING WITH WOOD FIBRE INSULATING MATERIALS

HEALTHY LIVING WITH WOOD FIBRE INSULATING MATERIALS HEALTHY LIVING WITH WOOD FIBRE INSULATING MATERIALS HIGH-QUALITY INSULATION. SUSTAINABLE LIVING. www.homatherm.com Preamble THE EXAMPLE OF NATURE Sustainable living to us means harnessing the forces of

More information

Mezzanine. Technical manual

Mezzanine. Technical manual TechNICAL MANUAL 1 Mezzanine Technical manual 2 Varnished (optional) Product class P6 Melamined (optional) Tongue and groove Structural applications STANDARD FEATURE additional options - Chipboard - Varnished

More information

Building Construction. Lightweight construction. Conventional Construction

Building Construction. Lightweight construction. Conventional Construction Ventilation 53 Building Construction The firefighter s ability to safely and efficiently ventilate a building through its roof will depend to some degree on the firefighter s understanding of roof construction.

More information

pinta ACOUSTIC PANEL [1/7]

pinta ACOUSTIC PANEL [1/7] [1/7] Too much echo in the workplace? Staff unable to concentrate on their work? The answer is: ACOUSTIC PANEL. Service Call our telephone hotline for advice on your individual situation. Animated installation

More information

Lightweight Partition Design for Residential and Commercial Buildings

Lightweight Partition Design for Residential and Commercial Buildings Lightweight Partition Design for Residential and Commercial Buildings Stanley D. Gatland II, CertainTeed Corporation, Valley Forge, Pennsylvania Guidelines are presented for the design and proper installation

More information

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01. Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice

More information

Page 1 of European Technical Approval ETA-09/0129, Issued on September 26, 2011, valid until June 3, 2014

Page 1 of European Technical Approval ETA-09/0129, Issued on September 26, 2011, valid until June 3, 2014 Page 1 of European Technical Approval ETA-09/0129, Issued on September 26, 2011, valid until June 3, 2014 VTT Expert Services Ltd PL 1001 02044 VTT Puh. +358 20 722 4911 Telekopio +358 20 722 7003 Rakennustuotedirektiivin

More information

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN Page 1 of European Technical Approval ETA-09/0129 VTT Valtion Teknillinen Tutkimuskeskus PL 1000 02044 VTT Puh. +358 20 722 4911 Telekopio +358 20 722 7003 Rakennustuotedirektiivin (89/106/EEC) artiklan

More information

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone: 0041 22 77 66 051 info@cardok.com CARDOK CARLIFT Fast access to underground garages Fast, Silent, Discreet, Design, High-Tech Installation to replace an access ramp on private property Dimensions: (Built to measure, all dimensions can

More information

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions.

Introduction. 1. Heat Transfer. In Townsville s climate it is essential to choose building materials that perform well in our local conditions. In Townsville s climate it is essential to choose building materials that perform well in our local conditions. Choosing the correct materials and insulation will improve the overall thermal performance

More information

H-Stud Area Separation Wall System

H-Stud Area Separation Wall System 12 TH EDITION 09 21 16.33/NGC H-Stud Area Separation Wall System 09 21 16.33 139 H-STUD AREA SEPARATION WALL SYSTEM The fire-protection of gypsum-based Area Separation Walls is demonstrated in dramatic

More information

The Case for Cross Laminated Timber: Part 2

The Case for Cross Laminated Timber: Part 2 Learning Objectives The Case for Cross Laminated Timber: Part 2 Opportunities and Challenges for a New Class of Timber Product 1. Review answers to common questions regarding the design and construction

More information

OWAplan1. The seamless acoustic ceiling. Pure acoustics. Pure design.

OWAplan1. The seamless acoustic ceiling. Pure acoustics. Pure design. OWAplan1 The seamless acoustic ceiling. Pure acoustics. Pure design. 3 Perspectives of freedom OWAplan It is time for a new way of thinking, for a new kind of freedom in room design, for taking a different

More information

European Technical Assessment ETA-15/0652 of 27/10/2015

European Technical Assessment ETA-15/0652 of 27/10/2015 ETA-Danmark A/S Göteborg Plads 1 DK-2150 Nordhavn Tel. +45 72 24 59 00 Fax +45 72 24 59 04 Internet www.etadanmark.dk Authorised and notified according to Article 29 of the Regulation (EU) No 305/2011

More information

SANDWICH PANEL FILLING MATERIALS

SANDWICH PANEL FILLING MATERIALS SANDWICH PANEL FILLING MATERIALS Materials such as Polyurethane, PIR, Polystyrene, Phenolic Foam and Rockwool, etc. are the filling core materials mostly preferred in sandwich panel applications. All the

More information

How To Certify The Scottsdale Construction System

How To Certify The Scottsdale Construction System BRE CERTIFICATION LIMITED PRODUCT SCOTTSDALE CONSTRUCTION SYSTEM CERTIFICATE NUMBER 129/07 DATE OF ISSUE December 2007 SUPPLIED BY Scottsdale Construction System Ltd SUMMARY The Scottsdale Construction

More information

Mold Preventing I nterior System

Mold Preventing I nterior System interior insulation and renovation boards A system of components that have been designed to work perfectly together to repair damage caused by mold. The system consists of boards, insulation wedges, reveal

More information

IMPACT DAMAGE RESISTANT WALL SYSTEMS

IMPACT DAMAGE RESISTANT WALL SYSTEMS IMPACT DAMAGE RESISTANT WALL SYSTEMS CONTENTS Introduction 2 Advantages 2 2 Material Specifications 2 Design Considerations 3 Framing 5 Plasterboard Installation 5 Health, Safety & Warranty 6 Contact Details

More information

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN

Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu tuotehyväksyntälaitos EOTAN JÄSEN VTT Expert Services Oy PL 1001 02044 VTT Puh. +358 20 722 4911 Telekopio +358 20 722 7003 Rakennustuotedirektiivin (89/106/EEC) artiklan 10, neuvoston direktiivi 21. joulukuuta 1988, mukaisesti notifioitu

More information

ANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests

ANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests ANSI/ASHRAE Standard 140-2004 Building Thermal Envelope and Fabric Load Tests DesignBuilder Version 1.2.0 (incorporating EnergyPlus version 1.3.0) - June 2006 1.0 Purpose The ANSI/ASHRAE Standard 140-2004

More information

STENCA PIPE. High quality pipe insulation. www.stenca.com

STENCA PIPE. High quality pipe insulation. www.stenca.com STENCA PIPE High quality pipe insulation WELCOME TO STENCA TRADING - Global focus with local service Stenca Trading offers optimal solutions for the offshore, marine, refineries and cogeneration industry.

More information

BER Assessors Dwellings Technical Bulletin

BER Assessors Dwellings Technical Bulletin BER Assessors Dwellings Technical Bulletin Issue No. 2/12 April 2012 Contents: 1. SUPPLEMENTARY ELECTRIC WATER HEATING IN SUMMER... 2 2. PITCHED ROOF U-VALUE CALCULATIONS... 8 2.1. PITCHED ROOF, INSULATED

More information

Under sill units. Type FSL-B-ZAS

Under sill units. Type FSL-B-ZAS .1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract

More information

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM Chapter 9 STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM 9.1 BACKGROUND Steel is widely used in the construction of multi-storey buildings. However, steel construction is seldom used and is traditionally

More information

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION Bill Robinson BSc. C. Eng. M. I. Struct. E. Timber Design Services 1 IS440 Timber frame

More information

ETAG 016 SELF-SUPPORTING COMPOSITE LIGHTWEIGHT PANELS. (Part one : G E N E R A L)

ETAG 016 SELF-SUPPORTING COMPOSITE LIGHTWEIGHT PANELS. (Part one : G E N E R A L) European Organisation for Technical Approvals Europäische Organisation für Technische Zulassungen Organisation Européenne pour l Agrément Technique Edition NOVEMBER 2003 GUIDELINE FOR EUROPEAN TECHNICAL

More information

Product Data Sheet ROCKPANEL Rockclad

Product Data Sheet ROCKPANEL Rockclad Product Data Sheet ROCKPANEL Rockclad Durable - Xtreme - FS-Xtra United Kingdom 1 Product description ROCKPANEL boards are prefabricated compressed mineral wool boards with synthetic binders. The surface

More information

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

CHESTERFLEX ROOF WATERPROOFING MEMBRANES CI/SfB (47) Ln2 Chesterfelt Ltd CHESTERFLEX ROOF WATERPROOFING MEMBRANES Certificate No 94/3062 DETAIL SHEET 2 Product THIS DETAIL SHEET RELATES TO CHESTERFLEX ROOF WATERPROOFING MEMBRANES, POLYESTER REINFORCED

More information

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5

Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Cl Sfb (27-9) Rn7 M2 December 2004 Built-up roofing solutions with rigid insulation boards on concrete decks for new-build and refurbishment E-a5 Fesco, Fesco S, Retrofit, Retrofit S, Fesco Fillet, PF,

More information

Light-Weight Panels. High quality panels. www.stenca.com

Light-Weight Panels. High quality panels. www.stenca.com Light-Weight Panels High quality panels WELCOME TO STENCA TRADING - Global focus with local service Stenca Trading offers optimal solutions for the offshore, marine, refineries and cogeneration industry.

More information

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape ModuSec Secure and efficient IT room solutions Turnkey Modular Construction Fast clean build to any size or shape Room in room Standalone external build Transportable Modusec SR Options Modusec SR Options

More information

Signs of insulation problems In the winter. In the summer. conditioning system

Signs of insulation problems In the winter. In the summer. conditioning system about your house CE 19 While previous generations may have been content to live in drafty houses, most people now want comfortable warm houses. A healthy house today is well sealed, well insulated and

More information

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS.

GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. GUIDANCE SHEET FOR CONSERVATORIES, SUNROOMS AND EXTENSIONS TO DWELLINGS. This leaflet provides guidance on how to attain compliance with The Building (Amendment) Regulations (Northern Ireland) 2006, Part

More information

Fire safety in timber buildings

Fire safety in timber buildings Fire safety in timber buildings Introduction Fire spread in buildings is a risk to life safety for which the Building Regulations (for England and Wales 1,2, Scotland 3 and Northern Ireland 4 ) aims to

More information

Manual lifting and handling

Manual lifting and handling Manual lifting and handling When installing British Gypsum products and systems care should be taken to ensure that appropriate methods of handling and lifting are adopted. The following guidance details

More information

TEXTILE FABRICS AS THERMAL INSULATORS

TEXTILE FABRICS AS THERMAL INSULATORS TEXTILE FABRICS AS THERMAL INSULATORS Zeinab S. Abdel-Rehim 1, M. M. Saad 2, M. El-Shakankery 2 and I. Hanafy 3 1 Mechanical Engineering Department of the National Research Center, Dokki, Giza, Egypt 2

More information

Energy Company Obligation (ECO): Technical Monitoring Questions

Energy Company Obligation (ECO): Technical Monitoring Questions Energy Company Obligation (ECO) Technical Monitoring Questions v1 30/05/2013 Energy Company Obligation (ECO): Technical Monitoring Questions Under ECO suppliers are required to instruct suitably qualified

More information

Polymeric membrane for roof waterproofing

Polymeric membrane for roof waterproofing Product Data Sheet Edition 09.2008 Revision no: 0 Identification no: 01 09 01 02 200 0 120000 Sarnafil TS 77-12 Polymeric membrane for roof waterproofing Construction Product Description Uses Characteristics