Annex of the certificate (Page 1/6) Accreditation Scope
|
|
- Georgina Collins
- 8 years ago
- Views:
Transcription
1 As a Testing Laboratory Annex of the certificate (Page 1/6) Accreditation Scope Address: Küçük Çiğli Mh. 8780/1 Sk. No:5 Çiğli İZMİR / TÜRKİYE Phone : Fax : egebolgelab@tse.org.tr Website : Tested Materials / Products EX LABORATORY Metallic materials Construction products Name of Test Tensile testing - Part 1: Method of test at room temperature (10kN-600kN) Brinell hardness test - Part 1: Test method 60 HBW 2.5/ HBW 2.5/ HBW 2.5/ HBW 2.5/187.5 Rockwell hardness test - Part 1: Test method 20 HRB-100 HRB 20 HRC-70 HRC Vickers hardness test - Part 1: Test method 150HV HV HV HV50 Reaction to fire tests - Ignitability of products subjected to direct impingement of flame - Part 2: Single flame source test Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item Testing Method (National, International standards, in house methods) TS EN ISO EN ISO ISO TS EN ISO EN ISO ISO TS EN ISO EN ISO ISO TS EN ISO EN ISO ISO TS EN ISO EN ISO ISO TS EN EN 13823
2 Annex of the certificate (Page 2/6) Accreditation Scope Tested Materials / Products (Construction products, continued) Name of Test Reaction to fire tests for products - Non- combustibility test Reaction to fire tests for products - Determination of the gross heat of combustion (calorific value) Reaction to fire tests for floorings - Part 1: Determination of the burning behaviour using a radiant heat source Thermal insulating materials for building applications - Determination of organic content Test methods for external fire exposure to roofs Testing Method (National, International standards, in house methods) TS EN ISO 1182 EN ISO 1182 ISO 1182 TS EN ISO 1716 EN ISO 1716 ISO 1716 TS EN ISO EN ISO ISO TS EN EN TS ENV 1187 ENV 1187 Construction Products Building Elements IP code For electrical equipments Electrical Apparatus for Explosive Gas Atmospheres Test 1 Method with burning brands Fire classification of construction products and building elements - Part 1: Classification using test data from reaction to fire tests Degrees of protection provided by enclosures (IP code) (For electrical equipments) Explosive Atmospheres - Part 1: Equipment Protection by Flameproof Encloures "d" TS EN EN TS 3033 EN EN TS EN EN IEC
3 Annex of the certificate (Page 3/6) Accreditation Scope Tested Materials / Products Non-electrical Equipment for Use in Potentially Explosive Atmospheres PACKAGING LABORATORY Name of Test Non-electrical Equipment for Use in Potentially Explosive Atmospheres - Part 3: Protection by Flameproof Enclosure "d " Testing Method (National, International standards, in house methods) TS EN EN IEC Paper Determination of Bursting Strength TS 3124 EN ISO 2758 EN ISO 2758 ISO 2758 Tissue paper Determination of Grammage TS EN ISO EN ISO ISO Paper and Board Determination of Thickness TS EN ISO 534 EN ISO 534 ISO 534 Corrugated Fibreboards Determination of Grammage TS 3122 EN ISO 536 EN ISO 536 ISO 536 Determination Of Water TS 609 EN Absorptiveness - COBB Method ISO 535 EN Determination Of Tensile Properties TS EN ISO (Constant Rate Of Elongation Method) EN ISO ISO Determination of Grammage TS 1119 Determination of Bursting Strength TS 3123 EN ISO 2759 EN ISO 2759 ISO 2759
4 Annex of the certificate (Page 4/6) Accreditation Scope Tested Materials / Products (Corrugated Fibreboards, continued) Name of Test Determination Of Water Absorptiveness - COBB Method Testing Method (National, International standards, in house methods) TS 1119 Distribution Packaging Plastics Woven Sacks Materials and Articles in Contact with Foodstuffs Determination of Flat Crush Resistance TS EN ISO 3035 EN ISO 3035 ISO 3035 Determination of edgewise crush TS EN ISO 3037 resistance (Unwaxed edge method) EN ISO 3037 ISO 3037 Vibration Tests ASTM D (3-300 Hz, g, mm) TS 1644 EN ISO 2247 EN ISO 2247 ISO 2247 Horizantal Impact Tests / Inclined Plane TS 1643 EN ISO 2244 Test (H=116 cm) EN ISO 2244 ISO 2244 Determination of Compression ASTM D Strength Determination of Tensile Strength TS EN ISO EN ISO ISO Test methods for overall migration into TS EN olive oil by total immersion EN Test methods for overall migration into TS EN aqueous food simulants by total EN immersion Test methods for overall migration into TS EN olive oil by cell EN
5 Annex of the certificate (Page 5/6) Accreditation Scope Tested Materials / Products (Materials and Articles in Contact with Foodstuffs, continued) Plastic Films Name of Test Test methods for overall migration into aqueous food simulants by cell Test methods for overall migration into olive oil using a pouch Test methods for overall migration into aqueous food simulants using a pouch Test methods for overall migration into olive oil by article filling Test methods for 'substitute tests' for overall migration from plastics intended to come into contact with fatty foodstuffs using test media iso-octane and 95 % ethanol Test methods for overall migration into aqueous food simulants by article filling Determination of Water Vapor Transmission Rate Testing Method (National, International standards, in house methods) TS EN EN TS EN EN TS EN EN TS EN EN TS EN EN TS EN EN ASTM F 1249 Plastics- Thermoplastics Determination of Oxygen Permeability ASTM D 3985 ASTM F 1307 ASTM F 1927 ISO Determination of the Melt Mass-Flow TS EN ISO Rate (MFR) and the Melt Volume-Flow EN ISO Rate (MVR) of Thermoplastics- Part ISO :Standart Method
6 Annex of the certificate (Page 6/6) Accreditation Scope Tested Materials / Products Packaging Used for Transport of Dangerous Goods Non-metalic Materials Name of Test Testing Method (National, International standards, in house methods) Stacking Load Test ( max kg.) TS EN ISO Clause 7.2 Exposure to UV radiation EN ISO ISO ASTM G154 TS EN ISO EN ISO ISO End of Scope Dr. H. İbrahim ÇETİN Secretary General
7 Annex of the certificate (Page 1/10) As a Testing Laboratory Address: Küçük Çiğli Mh. 8780/1 Sk. No:5 Çiğli İZMİR / TÜRKİYE Phone Fax : : egebolgelab@tse.org.tr Website : EX LABORATORY 95/467/EC Gypsum products (1/4) : - Plasterboards and ceiling elements with thin laminations, fibrous gypsum boards, fibrous gypsum plaster casts, and composite panels (laminates), in which the incorporated material is placed on a face susceptible to be explosed to fire, including relevant ancillary products (in walls, partitions or ceilings (or lining thereof) subject to reaction to fire requirements). 95/467/EC Gypsum products (2/4) : - Plasterboards, blocks, ceiling elements and gypsum plasters, fibrous gypsum plasters casts, including relevant ancillary products (in walls, partitions or ceilings, as relevant, intended for fire protection of structural elements and/or fire compartmentation in buildings). EN EN EN EN EN EN 13963/AC EN EN EN EN EN A1 EN A1 EN EN EN 520+A1
8 Annex of the certificate (Page 2/10) 96/580/EC 97/462/EC Curtain wallings (1/1) : - Curtain wall kits (as external walls not subject to reaction to fire requirements). Wood-based panels (2/2) : - Unfaced, overlaid and veneered or coated wood-based panels (for non structural elements in internal or external applications). 97/740/EC Masonry and related products (3/3) : - 97/808/EC 97/808/EC Masonry units incorporating thermal insulating materials placed on a face susceptible to be exposed to fire (in walls and partitions subject to reaction to fire regulations). Floorings (2/2) : - Floor screed materials (for internal uses). Floorings (2/2) : - Rigid flooring products (a) Components: paving units, tiles, mosaics, parquet, decking of mesh or sheet, floor gratings, rigid laminated floorings, wood based products (for internal uses including enclosed public transport premises). EN EN EN EN EN EN 12058
9 Annex of the certificate (Page 3/10) 97/808/EC Floorings (2/2) : - Resilient and textile floorings - homogeneous and heterogeneous resilient floor coverings supplied either in tile, sheet or roll form (textile floor covering including tiles; plastic and rubber sheets (aminoplastic thermosetting floorings); linoleum and cork; anti-static sheet; floor loose laid tiles; resilient laminated floorings) (for internal uses). windows and ancillary products (2/6) : - Factory-bonded composite or sandwich panels (for uses subject to reaction to fire regulations). windows and ancillary products (2/6) : - Rooflights (for uses subject to reaction to fire regulations). windows and ancillary products (2/6) : - Flat and profiled sheets (for uses subject to reaction to fire regulations). EN EN 14041/AC EN EN EN 14509/AC EN EN 1873 EN EN EN 534+A1
10 Annex of the certificate (Page 4/10) windows and ancillary products (2/6) : - Roofing tiles, slates, stones and shingles (for uses subject to reaction to fire regulations). windows and ancillary products (2/6) : - Roof windows (for uses subject to reaction to fire regulations). windows and ancillary products (3/6) : - Factory-bonded composite or sandwich panels (for uses subject to external fire performance regulations). windows and ancillary products (3/6) : - Roofing tiles, slates, stones and shingles (for uses subject to external fire performance regulations). EN EN 1304 EN 490 EN 490/A1 EN 492 EN 492/A1 EN 494+A3 EN 544 EN A1 EN EN 14509/AC EN EN 1304 EN 490 EN 490/A1 EN 492 EN 492/A1 EN 494+A3 EN 544
11 Annex of the certificate (Page 5/10) 98/437/EC 98/437/EC 98/437/EC 98/437/EC windows and ancillary products (3/6) : - Roof windows (for uses subject to external fire performance regulations). windows and ancillary products (3/6) : - Rooflights (for uses subject to external fire performance regulations). Internal and external wall and ceiling finishes (3/5) : - Cladding slabs (as external finishes in walls or ceilings subject to reaction to fire regulations). Internal and external wall and ceiling finishes (3/5) : - Shingles (as external finishes in walls or ceilings subject to reaction to fire regulations). Internal and external wall and ceiling finishes (3/5) : - Suspended ceilings (kits) (as internal or external finishes in ceilings subject to reaction to fire regulations). Internal and external wall and ceiling finishes (3/5) : - Coverings in roll form (as internal finishes in walls or ceilings subject to reaction to fire regulations). EN A1 EN EN 1873 EN 1469 EN EN 12467/A2 EN EN 13964/A1 EN 14716
12 Annex of the certificate (Page 6/10) 98/437/EC 98/437/EC 99/90/EC 99/90/EC 99/90/EC 99/90/EC Internal and external wall and ceiling finishes (3/5) : - Sidings (as internal or external finishes in walls or ceilings subject to reaction to fire regulations). Internal and external wall and ceiling finishes (3/5) : - Panels (as internal or external finishes in walls or ceilings subject to reaction to fire regulations). Membranes (2/3) : - Roof sheets (for uses subject to reaction to fire regulations). Membranes (2/3) : - Damp proofing sheets (for uses subject to reaction to fire regulations). Membranes (2/3) : - Water vapour control layers (for uses subject to reaction to fire regulations). Membranes (2/3) : - Damp proof courses (for uses subject to reaction to fire regulations). EN EN /AC EN EN 14915/AC EN 534+A1 EN EN A1 EN A2 EN EN 13956/AC EN EN 13967/A1 EN EN 13969/A1 EN A1 EN A1 EN EN 13970/A1 EN EN 13984/A1 EN EN 14967
13 Annex of the certificate (Page 7/10) 99/90/EC Membranes (3/3) : - Roof sheets (for uses subject to external fire performance regulations). 99/91/EC Thermal insulating products (2/2) : - Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire). 99/91/EC Thermal insulating products (2/2) : - Thermal insulating products (factory-made products and products intended to be formed in-situ) (for uses subject to regulations on reaction to fire). EN A2 EN EN 13956/AC EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN 14934
14 Annex of the certificate (Page 8/10) 99/469/EC Products related to concrete, mortar and grout (2/2) : - Concrete protection and repair products (for uses subject to reaction to fire regulations). 99/470/EC Construction adhesives (2/2) : - Adhesives for tiles (for uses subject to reaction to fire regulations) 99/471/EC Space heating appliances (2/2) : 99/472/EC 2000/245/EC - Space heating appliances without internal energy source (for uses subject to reaction to fire regulations). Pipes, tanks and ancillaries not in contact with water intended for human consumption (4/5) : -Tanks (in installations in areas subject to reaction to fire regulations, used for the transport/disposal/storage of water not intended for human consumption) Flat glass, profiled glass and glass-block products (2/6) : - Insulating glass units (for uses subject to reaction to fire regulations) EN EN EN EN EN A1 EN 442-1/ A1 EN A1 EN A2
15 Annex of the certificate (Page 9/10) 2000/245/EC 2000/245/EC Flat glass, profiled glass and glass-block products (2/6) : - Flat or curved glass panels (for uses subject to reaction to fire regulations). Flat glass, profiled glass and glass-block products (3/6) : - Insulating glass units (for uses subject to external fire performance regulations). EN EN EN EN EN EN EN 14449/AC EN EN EN EN A2
16 Annex of the certificate (Page 10/10) 2000/245/EC Flat glass, profiled glass and glass-block products (3/6) : - Flat or curved glass panels (for uses subject to external fire performance regulations). End of Scope EN EN EN EN EN EN EN EN EN 14449/AC EN EN EN EN EN Dr. H. İbrahim ÇETİN Secretary General
Mandate M/119 FLOORINGS
Mandate M/119 Page 1 sur 14 Mandate M/119 MANDATE TO CEN/CENELEC CONCERNING THE EXECUTION OF STANDARDISATION WORK FOR HARMONIZED STANDARDS ON CReatE RELATED TO THE FOLLOWING END USES FLOORINGS 01/33 :
More informationCERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
More informationDubai Municipality Standard DMS 1: Part 5: 2004
Specification for precast concrete blocks Part 5: Normal-weight concrete-polystyrene sandwich masonry blocks Issue Date Revision Revision Description Prepared by Approved by Authorized by 19/12/2004 Issue
More informationCavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.
CI/SfB Tn6 L6813 September 2013 RIW CAVITY DRAIN R20 R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high. Other systems are available for specific uses,
More informationALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE
Mapeguard WP System ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE Products used: Mapeguard WP 200, Mapeguard ST, Mapeguard IC, Mapeguard EC, Mapeguard WP
More informationProduct Guide Specification
Reef Industries, Inc. 9209 Almeda Genoa Rd. Houston, Texas 77075 Toll Free (800) 231-6074 Phone (713) 507-4251 Fax (713) 507-4295 Web Site www.reefindustries.com E-Mail ri@reefindustries.com Product Guide
More informationIf you are a web registered user of ArlingontPermits.com you may also request an inspection at:
TECHNICAL BULLETIN Community Development & Planning, Building Inspections TOPIC: Permits & Inspections for Roofing Replacement Effective November 1, 2011 Revised This Technical Bulletin will provide contractors
More informationEXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS
EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS 1. SCOPE 1.1 This specification covers the type, physical properties and dimensions of Expanded Polystyrene Insulation Board intended for use
More informationTHERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST
THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST Instruction: Check each test method for which you are requesting accreditation. An asterisk beside the NVLAP Test Method Code indicates that proficiency
More informationFire 2This Technical Bulletin has been commissioned by the UK SIP Association in
REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory
More informationISO Types 1-6: Construction Code Descriptions
ISO 1 Frame (combustible walls and/or roof) Class 1B Buildings where the exterior walls are wood or other combustible materials, including construction where the combustible materials are combined with
More informationRockwool Flexi Insulation Application Guide
Pitched roof Rafters InterMediate floors INTERNAL partitions external Framed walls separating floors Separating Walls Rockwool Flexi Insulation Application Guide Ground floor The perfect fit for any framed
More informationSection 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.
Section 5.0 Basements Wall insulated externally Product: Polyfoam ECO Ba01 Wall insulated internally Product: Polyfoam ECO Ba02 Basements Basements Basement design Waterproofing BS 8102: 2009 Code of practice
More informationEuropean Technical Approval ETA 13/0526
European Technical Approval ETA 13/0526 Trade Name Holder of the approval Website Generic type and use of construction product DOLCEA i3 PCIM S.A. Rue du Péquet 54 5590 Achene (Ciney) Belgium www.isoproc.eu
More informationThe assessment is described in the following pages which form integral parts of this certificate, which should be read in its entirety.
Cl/SfB (13.1) Ly (L2) BRE CERTIFICATION LTD CERTIFICATE OF ASSESSMENT PRODUCT Powerbase RB 340 and RB 370 Radon Resistant Membranes CERTICATE NO. 100/03 ISSUED: MARCH 03 REISSUED: NOVEMBER 07 SUPPLIED
More informationSpecifications, Product Testing and Terminology
Specifications, Product Testing and Terminology The following synopsis provides a review of various material and final product testing, which is performed on our products, as well as, many of our competitors.
More informationPhysically Crosslinked Foam Insulation
Physically Crosslinked Foam Insulation Thermobreak is the original All in One flexible thermal insulation made from physically crosslinked closed cell polyolefin foam, factory fused to a reinforced 9um
More informationIntroduction. Facade Fire Test on PUR External Thermal Insulation Composite System (ETICS)
1 Facade Fire Test on PUR External Thermal Insulation Composite System (ETICS) Introduction The new harmonised system for the classification of reaction to fire in EU member states is using the SBI test
More informationConstruction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description
Product Data Sheet Edition 15/10/2014 Identification no: 02 07 04 10 300 0 000002 SikaProof A Edge SikaProof A-08 Edge, A-12 Edge Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing
More informationCHESTERFLEX ROOF WATERPROOFING MEMBRANES
CI/SfB (47) Ln2 Chesterfelt Ltd CHESTERFLEX ROOF WATERPROOFING MEMBRANES Certificate No 94/3062 DETAIL SHEET 2 Product THIS DETAIL SHEET RELATES TO CHESTERFLEX ROOF WATERPROOFING MEMBRANES, POLYESTER REINFORCED
More informationHIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS
BSW HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS BSW is a fully reinforced Pre-Applied system membrane designed for horizontal and vertical external blind-side
More informationHOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663)
HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663) Fire-Retardant-Treated Wood Framed Wall Assemblies GENERAL INFORMATION Fire-resistant construction
More informationBuilding Owners Guide to a Duro-Last System!
Building Owners Guide to a Duro-Last System Table of Contents Section 1: Introduction to Duro-Last Roofing Systems Section 2: Benefits of a Duro-Last Roofing System Section 3: Comparing a Duro-Last Roof
More informationCOMMERCIAL BUILDING APPLICATIONS
EXPANDED POLYSTYRENE FOR COMMERCIAL BUILDING APPLICATIONS www.falconfoam.com Commercial Building Ap Expanded Polystyrene Insulation Falcon Foam leads the commercial building industry with products that
More informationThe Kingspan Insulation Price List 1 st January 2013
Insulation The Kingspan Insulation Price List 1 st January 2013 FOR BUILDING FABRIC INSULATION, CAVITY CLOSERS AND MEMBRANES Visit our website: www.kingspaninsulation.co.uk Low Energy - Low Carbon Buildings
More informationConstruction. 3-part thixotropic epoxy patching mortar. Product Description. Tests
Product Data Sheet Edition 05/12/2014 Identification no: 020204030010000044 Sikadur -41 CF Rapid 3-part thixotropic epoxy patching mortar Construction Product Description Uses Characteristics / Advantages
More informationMineral fibreglass insulation
Isover MULTIMAX 30 Specification code: MW - EN 13162 - T5 - MU1 - WS - WL(P) - AF r 5 TeChNICaL SPeCIFICaTION Insulating slabs made of Isover fibreglass wool. The production method is based on the fibering
More informationRequirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**
PHRC Webinar Series Tuesday, September 9, 2014 1:00 pm Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited** Presented by: Bryan Heitzmann Credit(s) earned on completion of
More informationSchlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing
Substrate, structural panel, bonded waterproofing The universal substrate for tiles Perfect covering No matter whether you work with mosaics or large format tiles, an absolutely level substrate with straight
More informationGround Gas Barriers. www.tritonsystems.co.uk
Minimum 2 Coats Triton TTVM 0.5l/m² 1st Coat 0.7l/m² 2nd Coat 3 Coats Triton TTVM Incorporating GRM MSSM to Joints Triton Fillet Seal 25mm x 25mm Minimum Construction Joint Ground Gas Barriers n HDPE/PP
More informationLITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -
The original section of this building was constructed in 1941. The exterior walls are built of good quality stone. In the early 1980 s a similar addition was added to the north elevation. The exterior
More informationMold Preventing I nterior System
interior insulation and renovation boards A system of components that have been designed to work perfectly together to repair damage caused by mold. The system consists of boards, insulation wedges, reveal
More informationUnderstanding BS EN 771-3: Aggregate concrete masonry units
60 Charles Street, Leicester LE1 1FB Tel: 0116 253 6161 Fax: 0116 251 4568 Email: enquiries@cba-blocks.org.uk Website: www.cba-blocks.org.uk February 2006 Understanding BS EN 771-3: Aggregate concrete
More informationLAYING BLOCK AND BRICK
LAYING BLOCK AND BRICK Products highlighted in this section: SAKRETE Type N Mortar Mix SAKRETE Type S Mortar Mix Brick And Block Laying Basics The first step in building a brick or block wall is to construct
More informationComposite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
More informationVOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10
VOLUME V GUIDELINES FOR DESIGN CONSULTANT TABLE OF CONTENTS APPENDIX B: MASTER CONSTRUCTION SPECIFICATIONS AND PREPARATION GUIDE, DIVISIONS 0-10 SECTION B1: PREPARATION GUIDE B1.1 INTRODUCTION... B1-1
More informationBuilding Control Guidance Note
Elements Renovation / Replacement. Issued 25/01/13 Rev a Page 1 of 9 (Applies to both Domestic and Non-Domestic Premises) Works relating to thermal elements can arise in building an extension, a material
More informationManual lifting and handling
Manual lifting and handling When installing British Gypsum products and systems care should be taken to ensure that appropriate methods of handling and lifting are adopted. The following guidance details
More informationMapei systems for radiating floor heating with high thermal efficiency
Mapei systems for radiating floor heating with high thermal efficiency PRODUCTS FOR CERAMIC TILES AND STONE MATERIAL ADHESIVES SEALANTS CHEMICAL PRODUCTS FOR BUILDING III MAPEI systems for radiating floor
More informationROXUL Board Insulation Section 07 21 13 Master Guide Specification (CAVITYROCK ) Page 1 April 2016
Master Guide Specification (CAVITYROCK ) Page 1 Click on the pilcrow in the MS Word Toolbar to toggle ROXUL GUIDE NOTES on and off. Delete this text before incorporating the section into a Project Manual.
More informationTest report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA 18000 / Israel. J. Magner Dipl.-Ing. N. Machill.
Kiwa Polymer Institut GmbH Quellenstraße 3 65439 Flörsheim-Wicker Tel. +49 (0)61 45-5 97 10 Fax +49 (0)61 45-5 97 19 www.kiwa.de Test report P 7013-E Testing order: Test of the waterproofing system based
More information07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
More informationThermal insulation materials made of rigid polyurethane foam (PUR/PIR)
Report N 1 (October 06) Thermal insulation materials made of rigid polyurethane foam (PUR/PIR) Properties - Manufacture Rigid polyurethane foam (PUR/PIR) is one of the most efficient, high performance
More informationFire testing for BCA compliance
Fire testing for BCA compliance SFS NSW Chapter December 2010 Vince Dowling Fire Science and Technology Australia Standards and Specifications Type Purpose Examples Test method How to do the test and what
More informationRESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000
RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000 SECTION R905 REQUIREMENTS FOR ROOF COVERINGS R905.1 Roof covering application. Roof coverings
More informationEfficiently Maintaining Commercial Buildings. Asbestos Awareness
Efficiently Maintaining Commercial Buildings Asbestos Awareness What are the risks? Asbestos was used extensively between the 1950s and 1980s in both domestic and commercial buildings and although its
More informationThe Case for Cross Laminated Timber: Part 2
Learning Objectives The Case for Cross Laminated Timber: Part 2 Opportunities and Challenges for a New Class of Timber Product 1. Review answers to common questions regarding the design and construction
More informationEuropean technical approval
Authorised and notified according to Article 10 of the Council Directive 89/ 106/EEC of 21 December 1988 on the approximation of laws, regulations and administrative provisions of Member States relating
More informationFire Testing of Recycled Materials for Building Applications
Fire Testing of Recycled Materials for Building Applications Robert H. White Abstract To gain wide market acceptance of new building products made from recycled materials, fire testing may be necessary.
More informationPB301 July 2009. Lightweight Building Solutions. Bushfire Protection. www.boral.com.au/bushfireprotection
PB301 July 2009 Lightweight Building Solutions Bushfire Protection www.boral.com.au/bushfireprotection Attached or adjacent within 6m roofed structures such as garages, carports, verandas and the like,
More informationInstallation Instructions
Installation Instructions Pedestal Models FS 500 LE FS 800 LE Insert Models IS 500 LE IS 800 LE Pecan Engineering Pty Ltd 13 Acorn Road Dry Creek South Australia 5094 Email info@pecan-eng.com.au Phone:
More informationWATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12
WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12 87 88 GOOD INDUSTRY PRACTICES 12 WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12.1 BACKGROUND Most roofs in Singapore are constructed using reinforced
More informationSchedule of Accreditation issued by United Kingdom Accreditation Service 21-47 High Street, Feltham, Middlesex, TW13 4UN, UK
21-47 High Street, Feltham, Middlesex, TW13 4UN, UK to provide product conformity Stocking Lane High Wycombe Buckinghamshire HP14 4ND Contact: Mr Alan Gower Tel: +44 (0)1494 569700 Fax: +44 (0)1494 569701
More information16 2 10.3 Materials and Colors
16 2 10.3 Materials and Colors To create a harmonious and coherent image for each development, building designs shall pay close attention to choice of materials and colors. Building construction shall
More informationMandate M/116 MASONRY AND RELATED PRODUCTS
Mandate M/116 Page 1 sur 19 Mandate M/116 MANDATE TO CEN/CENELEC CONCERNING THE EXECUTION OF STANDARDISATION WORK FOR HARMONIZED STANDARDS ON CReatE MASONR AND RELATED PRODUCTS RELATED TO THE FOLLOWING
More informationInsulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW
Insulated Roof & Wall Panels Trapezoidal Insulated Roof Panels KS1000 RW Overview Kingspan roof panel systems present a superior system compared to conventional multi-part site assembled systems. They
More informationTwiga Insul. India's Leading Thermal and Acoustic Insulation. Insulating India
Twiga Insul India's Leading Thermal and Acoustic Insulation Insulating India Insulating India Twiga is the leading manufacturer of glass wool insulation in India, with a twenty-five year track record of
More informationDivision 9. SignaFlor Pad and Pour Flooring System
Division 9 SignaFlor Pad and Pour Flooring System SPECIFICATIONS Page 1. General... 2 1.1 Description 2 1.2 Quality Assurance 2 1.3 Submittals 2 1.4 Delivery and Storage 3 1.5 Warranty 3 1.6 Working Conditions
More informationStonewool Insulation for Thermal, Acoustic and Fire Safety Building Applications
Stonewool Insulation for Thermal, Acoustic and Fire Safety Building Applications www.kimmcoinsulation.com Our Insulation Business As the market leader in the GCC, Turkey and India, the Insulation Group
More informationEnvironmental Education Associates. Asbestos in Construction
Environmental Education Associates Asbestos in Construction Asbestos What Is It? 1-2 Asbestos is a naturally occurring mineral, found in rock form and is mined from the earth similar to iron, lead, and
More informationSection 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with
Section Separating Floors Timber frame floor with I-Beams Product: Earthwool Acoustic Roll and Floorfoam Easy Edge Strip Timber frame floor with solid timber joists Product: Earthwool Acoustic Roll and
More informationSealfire W1000 Compound. (2 references for the same product) Fire Stopping and Sealing Product: Penetration Seals
UL INTERNATIONAL (UK) LTD Wonersh House, Building C, The Guildway, Old Portsmouth Road, Guildford. GU3 1LR. United Kingdom. Phone : +44 1483 302130 Fax : +44 1483 302230 Email : Inform.NB@uk.ul.com Website
More informationWATERPROOFING OF WET ROOMS
WATERPROOFING OF WET ROOMS Waterproofing under tiles For longterm enjoyment of a wetroom area a complete and resistant waterproofing system is an important precondition. Most tiles are by themselves waterproof
More informationImproving the flood resistance of your home. Advice sheet 6: Flood-resilient floors
Improving the flood resistance of your home Advice sheet 6: Flood-resilient This sheet provides guidance on identifying different types of floor, assessing the routes floodwater may enter, and describes
More informationAsbestos in the home. www.tworivershousing.org.uk. for you - for your community - not for profit
Asbestos in the home www.tworivershousing.org.uk for you - for your community - not for profit Facts about asbestos, where it may be used and what to do if you find it. Introduction This leaflet addresses
More informationGENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)
GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES 1. PROTECTIVE SCREENS (a) Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic) Typically, 15 kg m -2 (1.3 mm) sheet lead or its shielding
More informationEUROPEAN STANDARDS PERSONAL PROTECTIVE CLOTHING FOR FLAME RESISTANT. Alexander Gstettner, Lenzing AG Austria
EUROPEAN STANDARDS FOR FLAME RESISTANT PERSONAL PROTECTIVE CLOTHING Alexander Gstettner, Lenzing AG Austria W a t e r How are the standards organized? A 1 Testing Methods Standards specifiying performance
More informationTechnical Specification Fire Blanket Firemaster Fire Protection-Cables Tray Fire Protection Department
INABENSA INABENSA Technical Specification Fire Blanket Firemaster Fire Protection-Cables Tray Fire Protection Department Blanket is a non-combustible flexible blanket made by alkaline earth silicate fibers,
More informationIFE Level 4 Certificate in Fire Science and Fire Safety (HL)
IFE Level 4 Certificate in Fire Science and Fire Safety (HL) Unit 2: Fire Safety Unit Reference Number: D/505/5932 Introduction This unit focuses on the prevention and detection of fire in premises and
More informationSub-Bid Contractor Update Statement. Tab A - Invitation for Bids. Tab B - Instructions to Bidders
INTRODUCTORY INFORMATION TABLE OF CONTENTS 00 0101 PROJECT TITLE PAGE PROCUREMENT REQUIREMENTS (PROJECT MANUAL) Tab A - Invitation for Bids Tab B - Instructions to Bidders Tab C Bid Form for General Bids
More informationFOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING
FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING insulation installed on foundation walls must be separated from the building interior with a code approved thermal barrier. Foam
More informationETAG 004 EXTERNAL THERMAL INSULATION COMPOSITE SYSTEMS WITH RENDERING
European Organisation for Technical Approvals Europäische Organisation für Technische Zulassungen Organisation Européenne pour l Agrément Technique Edition March 2000 Amendment June 2008 GUIDELINE FOR
More informationLoss Prevention Standard
Loss Prevention Standard LPS 1581: Issue 2.1 Requirements and tests for LPCB approval of nonload This Loss Prevention Standard is the property of BRE Global Ltd. and is made publicly available for information
More informationDavid O Brien, CMP Products (David.OBrien@cmp-products.com)
David O Brien, CMP Products (David.OBrien@cmp-products.com) 1) Main Function of Cable Glands 2) Common Issues with Cable Glands 3) Compliance / Standards, changing times 4) How do we select Cable Glands?
More informationAsbestos in the home. A guidance booklet for tenants. Please keep this document as a reference guide- It contains important safety information
Asbestos in the home A guidance booklet for tenants Please keep this document as a reference guide- It contains important safety information Introduction This guide is all about asbestos: what it is, its
More informationNominal Life Expectancy for Building Components
Nominal Life Expectancy for Building Components Building System Page A. HVAC 2 B. Elevator/Escalator 6 C. Plumbing 7 D. Roofing 8 E. Electrical 10 F. Fire/Life/Safety/Security System 11 G. Interior Finishes
More informationSTANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2
STANDARD for Plumbing, Heating, Hot Water, Cold Water & Electrical work undertaken by owners within the building known as Sussex Lodge London W2 & 16 Stanhope Terrace London W2 BPME Consulting Engineers
More informationAlways. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+
Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+ The wall sleeve The wall sleeve a largely unnoticed but very important sealing part. Wall sleeves
More informationFARMERS MUTUAL INSURANCE COMPANY UNDERWRITING GUIDELINES HOMEOWNER PROGRAM
UNDERWRITING GUIDELINES HOMEOWNER PROGRAM The following guidelines should be considered when offering insurance for certain types of risks. When evaluating the acceptability of a risk, the company underwriter
More informationRe-Cover Board-3. Insulation for Above the Deck ROOF WALL SPECIALTY
Insulation for Above the Deck WALL SPECIALTY PRODUCT DESCRIPTION Rmax Re-Cover Board-3 is an energy-efficient thermal insulation board composed of a closed-cell polyisocyanurate (polyiso) foam core bonded
More informationR-Value and Densities Chart
R-Value and Densities Chart Material R-Value Per Inch R-Value Per Unit Inside Air Film 0.68 Air Space between Studs 0.95 Building Pa 0.06 ½ in. Fiberboard Sheathing 1.52 Gypsum Wallboard or Drywall 0.90
More informationModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape
ModuSec Secure and efficient IT room solutions Turnkey Modular Construction Fast clean build to any size or shape Room in room Standalone external build Transportable Modusec SR Options Modusec SR Options
More informationkalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.
kalox-pool draft 231 KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete. repairing refurbishing and finishing 8-30 C Trowel / Spray 4 mm kalox-pool EN 1504-2 MAIN FEATURES
More information2014 British Columbia Building Code Changes
District of Houston 250-845-2238 2014 British Columbia Building Code Changes A District of Houston interpretation of the 2014 Building Code Changes for 9.36 & 9.32 The following changes reflect the most
More informationSECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront
PART 1 GENERAL 1.01 Work Included SECTION 08 41 1 ALUMINUM FRAMED ENTRANCES and STOREFRONTS System 402 Flush-Glazed Screw Spline Storefront A. Furnish and install aluminum architectural storefront system
More informationFIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS
INFORMATION PAPER IP 21/10 FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS Tom Lennon and Danny Hopkin The use of Structural Insulated Panel (SIP) systems in construction in the UK has increased
More informationSTAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM Installed in Pre-engineered Steel Buildings Provides Lowest Cost Construction Method for CORROSIVE AND WET Environments PREFERRED SOLUTIONS, INC.
More informationASBESTOS AWARENESS. Slide #1
ASBESTOS AWARENESS Slide #1 OBJECTIVES Participants will be able to: Describe what asbestos is. Identify in what components asbestos is typically found. Describe the health effects of exposure to asbestos.
More informationFiberglas, Exterior Wall Thermal Insulation
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
More informationETAG 016 SELF-SUPPORTING COMPOSITE LIGHTWEIGHT PANELS. (Part one : G E N E R A L)
European Organisation for Technical Approvals Europäische Organisation für Technische Zulassungen Organisation Européenne pour l Agrément Technique Edition NOVEMBER 2003 GUIDELINE FOR EUROPEAN TECHNICAL
More informationRenovation instructions
1(13) Renovation instructions The purpose of these instructions is to inform you of the things to consider when renovating an apartment. You can avoid many possible problems and additional costs following
More informationLoss Prevention Standard
Loss Prevention Standard LPS 1181: PART 1: ISSUE 1.1 Series of Fire Growth Tests for LPCB Approval and Listing of Construction Product Systems Part One: Requirements and Tests for Built-up Cladding and
More informationNCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)
NCMA TEK National Concrete Masonry Association an information series from the national authority on concrete masonry technology CONCRETE MASONRY FOUNDATION WALL DETAILS TEK 5-3A Details (2003) Keywords:
More information187123 REGGAE 30.3x34 cm./11.9"x13.4" D923. Natural Product that might suffer colour variations 1. PROPER PREPARATION OF SURFACE
187123 REGGAE 30.3x34 cm./11.9"x13.4" D923 Natural Product that might suffer colour variations 1. PROPER PREPARATION OF SURFACE The wall must be firm, levelled, dry and clean. Uneven surfaces greater than
More informationWater Damage & Repair
Water Damage & Repair Chinatown Preservation Talks 2015 James Engler, P.A Glenn Mason, AIA Mason Architects Program Outline Terminology & Waterproofing Basics Discussion of why this is important Below
More informationRenovating Your Basement
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Renovating Your Building America Report - 0309 2003 (revised 2007) Building Science Corporation Abstract:
More informationROOFERS CHOICE BREATHER MEMBRANES FOR USE IN COLD NON-VENTILATED ROOFS
Mercury Building Products Ltd 114 Eckington Road Coal Aston Dronfield Sheffield S18 3AY Tel: 01246 292816 Fax: 01246 292867 e-mail: sales@vaprfree.co.uk danny@vaprfree.co.uk website: www.mercurybuildingproducts.com
More informationVeMet, Utrecht, NL «Solution in Wear Protection» 26.10.2011 Dipl.-Ing. Wolfgang Leichnitz. Quit
VeMet, Utrecht, NL «Solution in Wear Protection» 26.10.2011 Dipl.-Ing. Wolfgang Leichnitz Quit Theory and Practice of Wear Definition In materials science, wear is the erosion of material from a solid
More informationFire-resistant barriers: background on requirements and determination method. Reading guide for test reports.
Fire-resistant barriers: background on requirements and determination method. Reading guide for test reports. Report number C 1395-1E-RA-003 d.d. May 14, 2014 Fire-resistant barriers: background on requirements
More informationSika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades
Construction Sika For Sealing and Waterproofing Construction Gaps in Building Façades Waterproof and Airtight Flexible Seal Controlled Vapour Diffusion Bonds to any Building Substrate Prevents Interstitial
More information