D161x-apmsl TECHNICAL DATA. Fiber Optic Pigtail. Features & Benefits

Similar documents
7.4 3M No Polish Connector

Reliable, Consistent, Quality

FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future

CISCO 10GBASE X2 MODULES

Plug - Type (Male/Female) Attenuators CAA series Singlemode

Patch Cords for Data Center Applications

UniCam High-Performance Connectors, Multimode and Single-Mode

12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)

Best Practices for Ensuring Fiber Optic System Performance. David Zambrano

Cisco SFP Optics for Gigabit Ethernet Applications

SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS

Guide to Patch Cords. and Pigtails.

USB 3.0 Cables. Color. Black Black Black Black Black Black Black Black Black Black

Loss & Continuity Testing with MPO/ MTP Connectors

Optical Fiber Data Center Field Testing. ANSI/BICSI Data Center Design and Implementation Best Practices

What testing is required for PREMISES Fiber Optic Cabling and the standards used

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

ETD Fiber Optic Products

DEFINING AND MEASURING PHYSICAL PARAMETERS OF PC POLISHED FIBER OPTIC CONNECTORS

QuickSpecs. Models HP X131 10G X2 CX4 Transceiver. HP X131 10G X2 Transceivers (SR, LRM, LR, ER and CX4) Overview. HP X131 10G X2 SC LRM Transceiver

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

Excel Pre-terminated Copper and Fibre Optic Systems

White Paper: 10GbE Fiber A Practical Understanding and Functional Approach

Cable Assemblies. A LANscape. Solutions Product

Polymer Coated Fiber Cable (PCF)

Splitter Solutions Brochure.

BLINK Triple-Play Connector

Cable Assembly Solutions at the Speed of Light

Arista 40G Cabling and Transceivers: Q&A

The Need for Low-Loss Multifiber Connectivity

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION STRUCTURE CABLING TESTING

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Pretium Connector Housings

200-Micron Single-Mode Fiber Enables New Cable Designs Copyright 2014 OFS FITEL, LLC

Overcoming OM3 Performance Challenges

Configuration RJ-45 (IEC ) 6-7. Categories and NEW terms EN , ISO/IEC De-embedded Re-embedded 14-15

Copper Patch Cords. Impact On Network Performance and Reliability

Resolution of comments 242 and 267 on Insertion loss measurements of installed fiber cables. Steve Swanson May 5, 2009

DATA CENTRES POWERED BY EXCEL

Cable Assemblies. Features and Benefits

Fiber Optics: Fiber Preparation and Fiber Connectors

ConnectorMax Analysis Software DELIVERING FAST PASS/FAIL ASSESSMENT OF CONNECTOR ENDFACES

DIAMOND AVIM Connector

Kit Highlights and Key Features

MTS/T-BERD Platforms Very Long Range (VLR) OTDR Module

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

Fiber Optic Terminus End Face Quality Standards

08. SEK IDC CONNECTORS

Attaching the PA-A1-ATM Interface Cables

Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand

TELENOR NETT SPECIFICATION

POLARIZATION MAINTAINING FIBER PATCHCORDS AND CONNECTORS

Cable Assemblies. Pretium EDGE Reverse Polarity Uniboots Photo LAN ST Compatible Ultra PC 12-Fiber Cable Assembly Photo LAN2784

Plug & Play Universal Systems

VARIABLE FIBER OPTIC ATTENUATORS BLOCKING PIGTAIL STYLE

ST800K-U Optical Power Meter. User Manual V1.0

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

Cable Assemblies. Corning Cable Systems

OFS AllWave Zero Water Peak (ZWP) single-mode

Field Installable Optical Connector for Cables

HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

Fibre optic testing best practices

10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance

Fiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable

TEST & INSPECTION. Featured Data Center Products. OTDRs Certification Test Kits Inspection Cleaning

M310 Data Center OTDR

Industry solutions: Broad cast

Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution.

Belden. Optical Fiber Catalog. One Enterprise. One Infrastructure. One Partner. Belden IBDN FiberExpress Systems

Field-Installable Fusion Splice-on Connector

How To Make A Data Center More Efficient

FCS-FCT-FCP Housings and Connector Panels. InfiniCor SX+ OM3, InfiniCor 600 OM2, InfiniCor 300 OM1, SMF 28e OS1/OS2

USB 3.0 Universal Mini Docking Station Adapter

BOTDR Measurement Techniques and Brillouin Backscatter Characteristics of Corning Single-Mode Optical Fibers

784 INTELLIGENT TRANSPORTATION SYSTEMS NETWORK DEVICES. (REV ) (FA ) (7-12)

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Keyed LC Connector Solution

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Copper Pre-terminated Assemblies

Optical Fibre Solutions

APPLICATIONS ROV & AUV SEISMIC PRODUCTION SYSTEMS DOWNHOLE JUMPER & CABLE SYSTEMS DRILLING CONTROL

Quick Installation Guide. Live! Titanium

OM4 Capability Brochure.

Optical Fibers Fiber Optic Cables Indoor/Outdoor

Measuring of optical output and attenuation

APPLICATION NOTE POLARIZATION MEASUREMENTS

Four Ways To Test Installed Fiber Optic Cables And How The Results Will Differ With Each Method

Fiber Optic. Passive Components Edition 2009

BICSI NxtGEN & Global Data Center Standards Update

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

MTP Optical Fibre Configurations

HARTING Ethernet Cabling 8-poles Overview

FIBER OPTIC ISOLATORS

DATA CENTRES NETWORKS

Transcription:

Features & Benefits Suitable for fiber splicing in Patch panels and Joint Closures. Compatible with DME PROLINK s equipment components Available in LC, ST & SC terminations. Available in different lengths. Easy to install and terminate. Connector compliant with IEC JIS, TIA/EIA. Complies with Telcordia GR-326-CORE clause 4.1 Ultra low Return & Insertion loss LSZH construction Available in ITU-T G652D and G657B zero water peak fiber.

Test Report Insertion Loss Test Test procedure : The test samples are measured in the following system. (Figure 1) The insertion loss (I.L) is defined as I.L = -10 log P0 / P1. The result data of measurement is an average of values measured 3 times. Test Reference : Telcordia Technologies Generic Requirements GR-326-CORE clause 4.1 Criteria : The product shall meet the Table-1 Optical Performance. Test Result & Judgment: (Table-1) Sample Test Result Step. 1 Step. 2 Step. 3 Average Judgment Cut PC APC PC APC PC APC PC APC - #1 0.15 0.16 0.16 0.15 0.18 0.18 0.16 0.16 PASS #2 0.17 0.2 0.18 0.19 0.18 0.22 0.18 0.2 PASS #3 0.2 0.19 0.19 0.18 0.22 0.17 0.2 0.18 PASS

Return Loss Test Test Procedure : The test samples are measured in the following system. (Figure 2) The result data of measurement is an average of values measured 3 times. Test Reference : Telcordia Technologies Generic Requirements GR-326-CORE clause 4.1 Criteria : The product shall meet the Table-2 Optical Performance. Test Result & Judgment: (Table-2) Sample Test Result Step. 1 Step. 2 Step. 3 Average Judgment Cut PC APC PC APC PC APC PC APC - #1 35.1 65.2 35.1 65.4 35.4 65.2 35.3 65.3 PASS #2 35.8 65.1 35.2 65.3 35.2 65.1 35.1 65.2 PASS #3 35.8 65.3 35 65.4 35 65.5 35 65.4 PASS

Difference between PC, UPC and APC Fiber optic cables have different types of mechanical connections. The type of connection determines the quality of the fiber optic light wave transmission. The different types are the flat-surface, Physical Contact (PC), Ultra Physical Contact (UPC), and Angled Physical Contact (APC). The original fiber connector is a flat-surface connection, or a flat connector. When mated, an air gap naturally forms between the two surfaces from small imperfections in the flat surfaces. The back reflection in flat connectors is about -14 db or roughly 4%. As technology progresses, connections improve. The most common connection now is the PC connector. Physical Contact connectors are just that the end faces and fibers of two cables actually touch each other when mated. In the PC connector, the two fibers meet, as they do with the flat connector, but the end faces are polished to be slightly curved or spherical. This eliminates the air gap and forces the fibers into contact. The back reflection is about -40 db. This connector is used in most applications. An improvement to the PC is the UPC connector. The end faces are given an extended polishing for a better surface finish. The back reflection is reduced even more to about - 55 db. These connectors are often used in digital, CATV, and telephony systems. The latest technology is the APC connector. The end faces are still curved but are angled at an industry-standard eight degrees. This maintains a tight connection, and it reduces back reflection to about -70 db. These connectors are preferred for CATV and analog systems. PC and UPC connectors have reliable, low insertion losses. But their back reflection depends on the surface finish of the fiber. The finer the fiber grain structure, the lower the back reflection. And when PC and UPC connectors are continually mated and remated, back reflection degrades at a rate of about 4 to 6 db every 100 matings for a PC connector. APC connector back reflection does not degrade with repeated matings.

D 1 6 1 x - a p m s l x Pin assigned by ECS 0-9 Inventory Management Index a Connector Type A-End ST ST SC SC LC LC FC FC p Polish Type P PC A APC U UPC m Mode 0 OM-1 1 OM-2 2 OM-3 3 OM-4 6 OS-1 7 OS-2

D 1 6 1 x - a p m s l s Specification 2D G.652D 7A1 G.657A1 7A2 G.657A2 7B G.657B 7B2 G.657B2 7B3 G.657B3 0 Not Applicable for MM l Length 1 1m 1.5 1.5m 2.5 2.5m

Web Site: Corporate Head Office: 3135-6900 Graybar Road, Richmond, BC V6W 0A5, Canada Phone: +1(604)276-9913 Fax: +1(604)276-9915. For a listing of all ECS Global Wire & Cable s Sales Office locations, please refer to our web site. Middle East Office: Jebel Ali Free Zone (South), Dubai, United Arab Emirates Phone: +971 (4) 811 8000 Fax: +971 (4) 8809360. Enquires to datacomm@ecsglobalwire.com. Specifications published here are current as of the date of publication of this document. Because we are continuously improving our products, ECS Global Wire & Cable reserves the right to change specifications without prior notice. At any time, you may verify product specifications by contacting ECS Global Wire & Cable s Regional Head Office in the UAE. June 2011 Original 2011 ECS Global Wire & Cable. All Rights Reserved