Fiber Optic. Passive Components Edition 2009
|
|
|
- Robert Martin
- 9 years ago
- Views:
Transcription
1 Fiber Optic Passive Components Edition 2009
2 Reliably connected to your network
3 Your partner for system solutions The HUBER+SUHNER Group is a leading global supplier of components and systems for electrical and optical connectivity. Our customers in Communications, Industrial and Transportation markets appreciate that we are specialists with detailed knowledge of practical applications. We offer technical expertise in radio frequency technology, fiber optics and lowfrequency under one roof, thus providing a unique basis for continual innovation focused on the needs of our customers all over the world. HUBER+SUHNER offers a wide asssortment of passive optical network components, optimized for applications in data centers and Fiber To The Home (FTTH). Due to the rapidly growing demands on the passive optical networks (PON) HUBER+SUHNER develops innovative and customized products and solutions in accordance to the current international standards. Our passive optical network components comply with highest optical and mechanical specifications. Excellence in Connectivity Solutions
4
5 Content Introduction and terminology 4 Fused couplers (FBT) singlemode 6 Planar splitters (PLC) singlemode 12 Fused couplers (FBT) multimode 22 Multiplexers (WDM) 28 Attenuators plug type 31 Attenuators in-line 37 Connector code 39 Excellence in Connectivity Solutions
6 Introduction Terminologies of passive network components Terms Attenuation Attenuator Bidirectional Broadband Device Center Wavelength Coupler Decibel (db) Demultiplexer Directivity Dual Window Excess Loss Fused Biconical Tapering (FBT) Insertion Loss (IL) Isolation Multiplexer Operating Wavelength Polarisation Dependent Loss (PDL) Planar Lightwave Circuit (PLC) Return Loss (RL) Single Window Splitter Splitting Ratio Uniformity Wavelength Division Multiplexing (WDM) Description Reduction of the signal magnitude, or loss, caused by absorption and scattering. Normally expressed in decibels (db) A passive device for reducing the amplitude of a signal without appreciably distorting the waveform A device, operating in both directions Optical broadband devices, covering a wide range of wavelengths The nominal operating wavelength of an optical device A bidirectional device with three or more fiber ends, combining the signals of two or more input ports into one output port. Also referred as splitter. A logarithmic unit of measurement for calculating the attenuation of an optical device or an optical system. A change of -3dB equates to the halving of the optical power A device that separates two or more multiplexed signals into its original single signals; the inverse of a multiplexer The amount of undesired optical signals observed at a given input port of a device. Also referred as near-end crosstalk (NEXT) A passive optical component that is optimised to operate a two different center wavelengths. For example at 1310 nm and 1550 nm Attenuation, or loss, of the optical component itself, not included any other attenuation effects of the device A manufacturing process for passive optical network components. It consist of twisting two bare fibers exactly to each other, stretching and then fusing the fibers together; tapering A sum of excess loss, splitting loss and loss caused by other optical effects The amount of undesired optical signals observed at a given output port of a device. Also referred as far-end crosstalk (FEXT) A device that combines two or more signals into a single output; the inverse of a demultiplexer. Multiplexer are usually operating bidirectional The wavelength, or wavelength range, on that a passive optical component is optimised for operating Attenuation caused by the state of polarisation (SOP). This optical effect results in a deviation between the maximum and minimum of loss on an optical device A manufacturing process for optical passive network components. It consist of a waveguide array that is applied to a silica chip by using a photolithographic masking process The ratio of optical power reflected back along the path of transmission, from either the coupling region, a connector or a terminated fiber. Normally expressed in decibels (db) A passive optical component that is optimised to operate at a single specified center wavelengths. For example at 1310 nm or 1550 nm A bidirectional device with three or more fiber ends, divides the signal of one input port into two ore more output ports. Also referred as coupler The percentage of optical power transferred to an output port of an optical device, with respect to the total power on all output ports of the device The maximum deviation of insertion loss between the different ports on a device within the operating wavelength Transmitting various signals at different wavelengths through the same fiber 4
7 Introduction Overview of optical transmission bands Band Wavelength range Description O Band 1260 nm 1360 nm Original band E Band 1360 nm 1460 nm Extended band S Band 1460 nm 1530 nm Short wavelength band C Band 1530 nm 1565 nm Conventional band L Band 1565 nm 1625 nm Long wavelength band U Band 1625 nm 1675 nm Ultra long wavelength band Conversion of attenuation to transmission ratio and attenuation ratio Attenuation (db) Transmition ratio (%) Attenuation ratio (%) 1.0 db ~ % ~ % 2.0 db ~ % ~ % 3.0 db ~ % ~ % 4.0 db ~ % ~ % 5.0 db ~ % ~ % 6.0 db ~ % ~ % 7.0 db ~ % ~ % 8.0 db ~ % ~ % 9.0 db ~ % ~ % 10.0 db ~ % ~ % 11.0 db ~ 7.90 % ~ % 12.0 db ~ 6.30 % ~ % 13.0 db ~ 5.00 % ~ % 14.0 db ~ 4.00 % ~ % 15.0 db ~ 3.20 % ~ % 16.0 db ~ 2.50 % ~ % 17.0 db ~ 2.00 % ~ % 18.0 db ~ 1.60 % ~ % 19.0 db ~ 1.30 % ~ % 20.0 db ~ 1.00 % ~ % 5
8 1 2 / 2 2 Dual Window FBT Coupler Features Low excess loss Low polarisation dependent loss (PDL) Excellent mechanical and environmental performance Applications Passive optical networks (B-PON, G-PON, E-PON) CATV networks and data communications Network monitoring Generic specifications Parameter Unit 50/50 40/60 30/70 20/80 10/90 5/95 1/99 Operating wavelength nm and Insertion loss * db / / / / / /0.3 Uniformity * db 0.7 n/a PDL * db 0.2 Return loss * db 55 Directivity db 55 Operating temperature C 25 to + 70 Package dimension P1, P2, P3 * Without connector loss Dimensional drawings Ø 3.0 Ø P1: Tubular package with 250 µm bare fibers P2: Tubular package with 0.9 mm buffered fibers P3: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables 6
9 1 2 / 2 2 Single Window FBT Coupler Features Low excess loss Low polarisation dependent loss (PDL) Excellent mechanical and environmental performance Applications Passive optical networks (B-PON, G-PON, E-PON) CATV networks and data communications Network monitoring Generic specifications Parameter Unit 50/50 40/60 30/70 20/80 10/90 5/95 1/99 Operating wavelength nm 1310 ± 40 or 1550 ± 40 Insertion loss * db / / / / / /0.2 Uniformity * db 0.6 n/a PDL * db 0.2 Return loss * db 55 Directivity db 55 Operating temperature C 25 to + 70 Package dimension P1, P2, P3 * Without connector loss Dimensional drawing Ø 3.0 Ø P1: Tubular package with 250 µm bare fibers P2: Tubular package with 0.9 mm buffered fibers P3: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables 7
10 1 2 / 2 2 FBT Coupler Ordering code BFC-5050 Description splitting ratio (applies for 1 2 or 2 2 couplers only) : : : : : : : ports wavelengths and 1550 nm dual window nm single window nm single window P2 package P1 Ø 3.0 mm / L=50 mm (for 250 µm coated fiber only) P2 Ø 3.0 mm / L=70 mm (for 0.9 mm TPE loose tube) P3 L=85 mm / W=18 mm / H=7.5 mm (for 0.9 mm TPE loose tube or 2.0 mm cable jacket) 001 version number 001 standard, 9 µm singlemode fiber 1 cable/fiber length 1 in meters, max. 3 meters X1 cable/fiber type X0 250 µm fiber with package P1 only (without connectors only) X1 0.9 mm TPE loose tube with package P2 or P3 X3 2.0 mm cable with package P3 only 70/70 connector code 1 st side / 2 nd side see last page for connector code BFC P X1-70/70 ordering code example for fused 1 2 / 2 2 coupler singlemode 8
11 1 N / 2 N Dual Window Tree Fused Coupler Features Low excess loss Low polarisation dependent loss (PDL) Excellent mechanical and environmental performance Applications Passive optical networks (B-PON, G-PON, E-PON) CATV networks Data communications Generic specifications Parameter Unit / / / / /2 16 Operating wavelength nm and Insertion loss * db Uniformity * db PDL * db Return loss * db 55 Directivity db 55 Operating temperature C 25 to + 70 Package dimension P4 P5 P6 * Without connector loss The splitting ratio on tree fused couplers is generally equal. Asymmetric splitting ratios are available upon request (e.g. 1 3 splitter with 10% 10% 80% splitting ratio) Dimensional drawing P4: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables P5: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables P6: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables 9
12 1 N / 2 N Single Window Tree Fused Coupler Features Low excess loss Low polarisation dependent loss (PDL)) Excellent mechanical and environmental performance Applications Passive optical networks (B-PON, G-PON, E-PON) CATV networks Data communication Generic specifications Parameter Unit / / / / /2 16 Operating wavelength nm 1310 ± 40 or 1550 ± 40 Insertion loss * db Uniformity * db PDL * db Return loss * db 55 Directivity db 55 Operating temperature C 25 to + 70 Package dimension P4 P5 P6 * Without connector loss The splitting ratio on tree fused couplers is generally equal. Asymmetric splitting ratios are available upon request (e.g. 1 3 splitter with 10% 10% 80% splitting ratio) Dimensional drawing P4: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables P5: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables P6: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables 10
13 1 N / 2 N Tree Fused Coupler Ordering code BFC-TREE Description TREE (applies for 1 N or 2 N concatenated tree fused couplers) 1 4 ports wavelengths and 1550 nm dual window nm single window nm single window P4 package for 0.9 mm tube jacket or 2.0 mm cable P4 L=100 mm; W = 80 mm; H = 7.5 mm P5 L=136 mm; W = 96 mm; H = 9.5 mm P6 L=160 mm; W = 110 mm; H = 11 mm 001 version number 001 standard, 9 µm singlemode fiber 1 cable length 1 in meters, max. 3 meters X1 cable type X1 0.9 mm TPE loose tube X3 2.0 mm cable 70/70 connector code 1st side / 2nd side see last page for connector code BFC-TREE P X1-70/70 ordering code example for Tree fused coupler singlemode 11
14 PLC Broadband Splitter Module Version with Ribbon Fiber Features PLC technology Low insertion loss, low PDL and small uniformity High temperature range Small design with up to 64 outputs Available in 1 N and 2xN configurations Applications Passive optical networks (B-PON, G-PON, E-PON) CATV networks and data communications Fiber optic equipments and systems Generic specifications 1 N standard and premium Parameter Unit Operating wavelength nm Insertion loss standard version* db Uniformity standard version* db Insertion loss premium version* db Uniformity premium version* db PDL * db Return loss * db 55 Directivity db 55 Operating temperature C 40 to + 85 Package dimension (L W H) mm x 12 x 4 * Without connector loss Generic specifications 2 N Standard and Premium Parameter Unit Operating wavelength nm Insertion loss standard version* db Insertion loss premium version* db Uniformity * db PDL * db Return loss * db 55 Directivity db 55 Operating temperature C 40 to + 85 Package dimension (L W H) mm * Without connector loss 12
15 PLC Broadband Splitter Module Version with Ribbon Fiber Dimensional drawings L W H Output length Input length 250 µm or 0.9 mm input fiber and ribbon output fiber L W Input length Ribbon length H Output length 250 µm or 0.9 mm input fiber and deribbonised 250 µm output fiber 13
16 PLC Broadband Splitter Module Version with Ribbon Fiber Dimensional drawings L W Manifold divider Input length Ribbon length H Output length 250 µm or 0.9 mm input fiber and ribbon fiber* output with manifold divider(s)**, no connectors L W Manifold divider Input length Ribbon length H Output length Connector terminated 0.9 mm input fiber and ribbon fiber * output with manifold divider(s) ** and connector terminated 0.9 mm loose tubes Note: * 1 2 and 1 4 splitter with fourfold ribbon fiber * 1 8 to 1 16 splitter with eightfold ribbon fiber(s) ** one manifold divider required per ribbon fiber Any other configuration on request. 14
17 PLC Broadband Splitter Module Version with Ribbon Fiber Order Code PLC ports Description planar lightwave circuit grade 0 1 standard grade premium grade 4 package 4 module package 001 sub-version 001 standard subversion 0 input fiber type Example: PLC / output fiber type input fiber length µm buffered fiber 0.9 mm buffered fiber µm deribbonised fiber 0.9 mm loose tube (with manifold divider) ribbon fiber 0.5 m 1.0 m 1.5 m 2.0 m 10 output fiber length m 1.0 m 1.5 m 2.0 m 83/ input connector type see connector table below 83 output connector type see connector table below Code Connector 00 none 30 FCPC 33 FCPC APC wide key 34 FCPC APC small key 70 SC Code Connector 73 SC APC 8 74 SC APC 9 80 LX.5 83 LX.5 APC Code Connector 85 LC 86 LC APC 90 LSH (E-2000 ) 93 LSH (E-2000 ) APC E-2000 is manufactured under licence of DIAMOND SA, CH LOSONE 15
18 PLC Broadband Splitter Small Hard Case Version Features PLC technology Low insertion loss, low PDL and small uniformity High temperature range Small design with up to 64 outputs Available in 1 N and 2 N configurations Applications Passive optical networks (B-PON, G-PON, E-PON) CATV networks and data communications Fiber optic equipments and systems Generic specifications 1 N standard and premium Parameter Unit Operating wavelength nm Insertion loss standard version* db Uniformity standard version* db Insertion loss premium version* db Uniformity premium version* db PDL * db Return loss * db 55 Directivity db 55 Operating temperature C 40 to + 85 Package dimension (L W H) mm upon request * Without connector loss Generic specifications 2 N Standard and Premium Parameter Unit Operating wavelength nm Insertion loss standard version* db Insertion loss premium version* db Uniformity * db PDL * db Return loss * db 55 Directivity db 55 Operating temperature C 40 to + 85 Package dimension (L W H) mm * Without connector loss 16
19 PLC Broadband Splitter Small Hard Case Version Dimensional drawing L W Input length H Output length Small hard case version with 900 µm buffered fibers on input and output L W Input length H Output length Small hard case version with connector terminated 900 µm buffered fibers on input and output 17
20 PLC Broadband Splitter Small Hard Case Version Order Code PLC ports Description planar lightwave circuit grade 0 standard grade 1 premium grade 8 package 8 small hard case package 001 sub-version 001 standard subversion 1 input fiber type mm buffered fiber 1 output fiber type mm buffered fiber 10 input fiber length Example: PLC / m 1.0 m 1.5 m 2.0 m 10 output fiber length m 1.0 m 1.5 m 2.0 m 83/ input connector type see connector table below 83 output connector type see connector table below Code Connector 00 none 30 FCPC 33 FCPC APC wide key 34 FCPC APC small key 70 SC Code Connector 73 SC APC 8 74 SC APC 9 80 LX.5 83 LX.5 APC Code Connector 85 LC 86 LC APC 90 LSH (E-2000TM) 93 LSH (E-2000TM) APC E-2000 is manufactured under licence of DIAMOND SA, CH LOSONE 18
21 PLC Broadband Splitter Standard Hard Case Version Features PLC technology Low insertion loss, low PDL and small uniformity High temperature range Small design with up to 64 outputs Available in 1 N and 2 N configurations Applications Passive optical networks (B-PON, G-PON, E-PON) CATV networks and data communications Fiber optic equipments and systems Generic specifications 1 N standard and premium Parameter Unit Operating wavelength nm Insertion loss standard version* db Uniformity standard version* db Insertion loss premium version* db Uniformity premium version* db PDL * db Return loss * db 55 Directivity db 55 Operating temperature C 40 to + 85 Package dimension** (L W H) mm x 100 x 20 * Without connector loss Generic specifications 2 N Standard and Premium Parameter Unit Operating wavelength nm Insertion loss standard version* db Insertion loss premium version* db Uniformity * db PDL * db Return loss * db 55 Directivity db 55 Operating temperature C 40 to + 85 Package dimension ** (L W H) mm * Without connector loss ** The package material is aluminium, black 19
22 PLC Broadband Splitter Standard Hard Case Version Dimensional drawing L W Input/output length H Standard hard case version with 0.9 mm buffered fibers or 2.0 mm cables on input and output L W Input/output length H Standard hard case version with connector terminated 0.9 mm buffered fibers or 2.0 mm cables on input and output 20
23 PLC Broadband Splitter Standard Hard Case Version Order Code PLC ports Description 0 grade package Example: PLC /83 planar lightwave circuit standard grade premium grade standard hard case package (material: aluminium, black) 001 sub-version 001 standard subversion 2 input fiber type output fiber type input fiber length mm buffered fiber 2.0 mm cable 0.9 mm buffered fiber 2.0 mm cable 0.5 m 1.0 m 1.5 m 2.0 m 10 output fiber length m 1.0 m 1.5 m 2.0 m 83/ input connector type see connector table below 83 output connector type see connector table below Code Connector 00 none 30 FCPC 33 FCPC APC wide key 34 FCPC APC small key 70 SC Code Connector 73 SC APC 8 74 SC APC 9 80 LX.5 83 LX.5 APC Code Connector 85 LC 86 LC APC 90 LSH (E-2000TM) 93 LSH (E-2000TM) APC E-2000TM is manufactured under licence of DIAMOND SA, CH LOSONE 21
24 1 2 / 2 2 Broadband FBT Coupler 50/125 µm Multimode Features Stable environmental performances Low excess loss High uniformity Applications Data link, LAN Network monitoring and mirroring Optical sensors Test equipments Generic specifications Parameter Unit 50/50 40/60 30/70 20/80 10/90 5/95 1/99 Operating wavelength nm Insertion loss * db / / / / / /1.5 Uniformity * db 1.5 n/a Return loss * db 40 Directivity db 40 Operating temperature C 25 to + 70 Package dimension P1, P2, P3 * Without connector loss Dimensional drawing Ø 3.0 Ø P1: Tubular package with 250 µm bare fibers P2: Tubular package with 0.9 mm buffered fibers P3: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables 22
25 1 2 / 2 2 Broadband FBT Coupler 62.5/125 µm Multimode Features Stable environmental performances Low excess loss High uniformity Applications Data link, LAN Network monitoring and mirroring Optical sensors Test equipments Generic specifications Parameter Unit 50/50 40/60 30/70 20/80 10/90 5/95 1/99 Operating wavelength nm Insertion loss * db / / / / / /1.0 Uniformity * db 1.5 n/a Return loss * db 40 Directivity db 40 Operating temperature C 25 to + 70 Package dimension P1, P2, P3 * Without connector loss Dimensional drawing Ø 3.0 Ø P1: Tubular package with 250 µm bare fibers P2: Tubular package with 0.9 mm buffered fibers P3: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables 23
26 1 2 / 2 2 Broadband FBT Coupler Multimode Ordering code BFC-5050 Description splitting ratio (applies for 1 2 or 2 2 couplers only) : : : : : : : ports wavelengths to 1600 nm broadband P2 package P1 Ø 3.0 mm / L=50 mm (for 250 µm coated fiber only) P2 Ø 3.0 mm / L=70 mm (for 0.9 mm TPE loose tube only) P3 L=85 mm / W=18 mm / H=7.5 mm (for 0.9 mm TPE loose tube or 2.0 mm cable jacket) 500 version number 500 standard, 50 µm multimode fiber 600 standard, 62.5 µm multimode fiber 1 cable/fiber length 1 in meters, max. 3 meters X1 cable/fiber type X0 250 µm fiber with package P1 only (without connectors only) X1 0.9 mm TPE loose tube with package P2 or P3 X3 2.0 mm cable with package P3 only 70/70 connector code 1st side / 2nd side see last page for connector code BFC P X1-70/70 ordering code example for fused 1 2 / 2 2 coupler multimode 24
27 1 N/2 N Broadband Tree Fused Coupler 50/125 µm Multimode Features Stable environmental performances Low excess loss High uniformity Applications Data link, LAN Network monitoring and mirroring Optical sensors Test equipments Generic specifications Parameter Unit / / /2 16 Operating wavelength nm Insertion loss * db Uniformity * db Return loss * db 40 Directivity db 40 Operating temperature C 25 to + 70 Package dimension P4 P5 P6 * Without connector loss The splitting ratio on tree fused couplers is generally equal. Asymmetric splitting ratios are available upon request (e.g. 1 3 splitter with 10% 10% 80% splitting ratio) Dimensional drawing P4: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables P5: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables P6: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables 25
28 1 N / 2 N Broadband Tree Fused Coupler 62.5/125 µm Multimode Features Stable environmental performances Low excess loss High uniformity Applications Data link, LAN Network monitoring and mirroring Optical sensors Test equipments Generic specifications Parameter Unit / / /2 16 Operating wavelength nm Insertion loss * db Uniformity * db Return loss * db 40 Directivity db 40 Operating temperature C 25 to + 70 Package dimension P4 P5 P6 * Without connector loss The splitting ratio on tree fused couplers is generally equal. Asymmetric splitting ratios are available upon request (e.g. 1 3 splitter with 10% 10% 80% splitting ratio) Dimensional drawing P4: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables P5: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables P6: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables 26
29 1 N / 2 N Broadband Tree Fused Coupler Multimode Ordering code BFC-TREE Description TREE (applies for 1 N or 2 N concatenated tree fused couplers) 1 4 ports wavelengths to 1600 nm broadband P4 package for 0.9 mm tube jacket or 2.0 mm cable P4 L=100 mm; W = 80 mm; H = 7.5 mm P5 L=136 mm; W = 96 mm; H = 9.5 mm P6 L=160 mm; W = 110 mm; H = 11 mm 500 version number 500 standard, 50 µm multimode fiber 600 standard, 62.5 µm multimode fiber 1 cable/fiber length 1 in meters, max. 3 meters X1 cable/fiber type X1 0.9 mm TPE loose tube X3 2.0 mm cable 70/70 connector code 1st side / 2nd side see last page for connector code BFC-TREE P X1-70/70 ordering code example for TREE fused coupler multimode 27
30 Fused Wavelength Division Multiplexers (WDM) Features Low excess loss High isolation High reliability Applications 1310 nm / 1550 nm simultaneous operation on a single fiber Network monitoring CATV Access passive optical network Generic specifications Parameter Unit Standard isolation High isolation Operating wavelength nm 1310 ± 10 and 1550 ± 10 Insertion loss * db Uniformity * db PDL on through channels* db Isolation * db Return loss * db 55 Directivity db 55 Operating temperature C 25 to + 70 Package dimension P1, P2, P3 P4 * Without connector loss 28
31 Fused Wavelength Division Multiplexers (WDM) Dimensional drawing Ø 3.0 Ø 3.0 P1: Tubular package with 250 µm bare fibers P2: Tubular package with 0.9 mm buffered fibers P3: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables P4: Ruggedised package with 0.9 mm buffered fibers or 2.0 mm cables 29
32 Fused Wavelength Division Multiplexers (WDM) Ordering code WDM-1 2 Description ports wavelengths and 1550 nm P2 package P1 Ø 3.0 mm: L = 50 mm Ø 3.0 mm: P2 L = 70 mm L = 85 mm P3 W = 18 mm H = 7.5 mm L = 100 mm P4 W = 80 mm H = 7.5 mm 001 version number 001 standard 002 high isolation 1 cable length 1 in meters, max. 3 meters X1 cable type for 250 µm coated fiber / standard isolation (without connectors only) for 0.9 mm TPE loose tube / standard isolation for 0.9 mm TPE loose tube and 2.0 mm cable / standard isolation for 0.9 mm TPE loose tube and 2.0 mm cable / high isolation X0 = available package: P1 X0 250 µm fiber (available without connectors only) X1 0.9 mm tube X1 = available package: P2, P3, P4 X3 2.0 mm cable X3 = available package: P3, P4 70/70 connector code 1 st side / 2 nd side see last page for connector code WDM P X1-70/70 ordering code example for fused WDM singlemode 30
33 Plug Type Attenuator SC Features Push-pull type Maximum stability and reliability Flat spectral response SC interface according to IEC Applications Passive optical networks (B-PON, G-PON, E-PON) Multi wavelength systems balancing Optical power receivers protection Specifications Parameter Value singlemode UPC Value singlemode APC Test method Wavelength bandwidth 1260 nm to 1360 nm and 1460 nm to 1625 nm Attenuation from 1 to 30 db, in steps of 1 db IEC Spectral tolerances ± 15% on nominal attenuation value (att 1 4 db) ± 10% on nominal attenuation value (att 5 30 db) IEC Repeatability of IL ± 0.1 db over service life Return loss > 50 db > 60 db IEC Durability min mating cycles Operating temperature 25 C to + 70 C Housing material Housing colour Ferrule zinc nickel plated metallic full ceramic Dimensional drawing 32.6 mm 12.8 mm 9.1 mm 31
34 Ordering Information Plug Type Attenuator SC Plug Type Attenuator SC/UPC Plug Type Attenuator SC/APC Attenuation Item no. Description 1.0dB OFA-FSC-U-010-S dB OFA-FSC-U-020-S dB OFA-FSC-U-030-S dB OFA-FSC-U-040-S dB OFA-FSC-U-050-S dB OFA-FSC-U-060-S dB OFA-FSC-U-070-S dB OFA-FSC-U-080-S dB OFA-FSC-U-090-S dB OFA-FSC-U-100-S dB OFA-FSC-U-110-S dB OFA-FSC-U-120-S dB OFA-FSC-U-130-S dB OFA-FSC-U-140-S dB OFA-FSC-U-150-S dB OFA-FSC-U-160-S dB OFA-FSC-U-170-S dB OFA-FSC-U-180-S dB OFA-FSC-U-190-S dB OFA-FSC-U-200-S dB OFA-FSC-U-210-S dB OFA-FSC-U-220-S dB OFA-FSC-U-230-S dB OFA-FSC-U-240-S dB OFA-FSC-U-250-S dB OFA-FSC-U-260-S dB OFA-FSC-U-270-S dB OFA-FSC-U-280-S dB OFA-FSC-U-290-S dB OFA-FSC-U-300-S Attenuation Item no. Description 1.0dB OFA-FSC-A-010-S dB OFA-FSC-A-020-S dB OFA-FSC-A-030-S dB OFA-FSC-A-040-S dB OFA-FSC-A-050-S dB OFA-FSC-A-060-S dB OFA-FSC-A-070-S dB OFA-FSC-A-080-S dB OFA-FSC-A-090-S dB OFA-FSC-A-100-S dB OFA-FSC-A-110-S dB OFA-FSC-A-120-S dB OFA-FSC-A-130-S dB OFA-FSC-A-140-S dB OFA-FSC-A-150-S dB OFA-FSC-A-160-S dB OFA-FSC-A-170-S dB OFA-FSC-A-180-S dB OFA-FSC-A-190-S dB OFA-FSC-A-200-S dB OFA-FSC-A-210-S dB OFA-FSC-A-220-S dB OFA-FSC-A-230-S dB OFA-FSC-A-240-S dB OFA-FSC-A-250-S dB OFA-FSC-A-260-S dB OFA-FSC-A-270-S dB OFA-FSC-A-280-S dB OFA-FSC-A-290-S dB OFA-FSC-A-300-S
35 Plug Type Attenuator FC Features Threaded nut type Maximum stability and reliability Flat spectral response FCPC interface according to IEC Applications Passive optical networks (B-PON, G-PON, E-PON) Multi wavelength systems balancing Optical power receivers protection Specifications Parameter Value singlemode UPC Value singlemode APC Test method Wavelength bandwidth 1260 nm to 1360 nm and 1460 nm to 1625 nm Attenuation from 1 to 30 db, in steps of 1 db IEC Spectral tolerances ± 15% on nominal attenuation value (att 1 4 db) ± 10% on nominal attenuation value (att 5 30 db) IEC Repeatability of IL ± 0.1 db over service life Return loss > 50 db > 60 db IEC Durability min mating cycles Operating temperature 25 C to + 70 C Housing material Housing colour Ferrule zinc nickel plated metallic full ceramic Dimensional drawing M mm M mm wrench size: male 2.14 mm, 0/ 0.05 female 2.15 mm, 0/
36 Ordering Information Plug Type Attenuator FC Plug Type Attenuator FC/UPC Plug Type Attenuator FC/APC Attenuation Item no. Description 1.0dB OFA-FCPC-U-010-S dB OFA-FCPC-U-020-S dB OFA-FCPC-U-030-S dB OFA-FCPC-U-040-S dB OFA-FCPC-U-050-S dB OFA-FCPC-U-060-S dB OFA-FCPC-U-070-S dB OFA-FCPC-U-080-S dB OFA-FCPC-U-090-S dB OFA-FCPC-U-100-S dB OFA-FCPC-U-110-S dB OFA-FCPC-U-120-S dB OFA-FCPC-U-130-S dB OFA-FCPC-U-140-S dB OFA-FCPC-U-150-S dB OFA-FCPC-U-160-S dB OFA-FCPC-U-170-S dB OFA-FCPC-U-180-S dB OFA-FCPC-U-190-S dB OFA-FCPC-U-200-S dB OFA-FCPC-U-210-S dB OFA-FCPC-U-220-S dB OFA-FCPC-U-230-S dB OFA-FCPC-U-240-S dB OFA-FCPC-U-250-S dB OFA-FCPC-U-260-S dB OFA-FCPC-U-270-S dB OFA-FCPC-U-280-S dB OFA-FCPC-U-290-S dB OFA-FCPC-U-300-S Attenuation Item no. Description 1.0dB OFA-FCPC-A-010-S dB OFA-FCPC-A-020-S dB OFA-FCPC-A-030-S dB OFA-FCPC-A-040-S dB OFA-FCPC-A-050-S dB OFA-FCPC-A-060-S dB OFA-FCPC-A-070-S dB OFA-FCPC-A-080-S dB OFA-FCPC-A-090-S dB OFA-FCPC-A-100-S dB OFA-FCPC-A-110-S dB OFA-FCPC-A-120-S dB OFA-FCPC-A-130-S dB OFA-FCPC-A-140-S dB OFA-FCPC-A-150-S dB OFA-FCPC-A-160-S dB OFA-FCPC-A-170-S dB OFA-FCPC-A-180-S dB OFA-FCPC-A-190-S dB OFA-FCPC-A-200-S dB OFA-FCPC-A-210-S dB OFA-FCPC-A-220-S dB OFA-FCPC-A-230-S dB OFA-FCPC-A-240-S dB OFA-FCPC-A-250-S dB OFA-FCPC-A-260-S dB OFA-FCPC-A-270-S dB OFA-FCPC-A-280-S dB OFA-FCPC-A-290-S dB OFA-FCPC-A-300-S
37 Plug Type Attenuator LC Features Latched push-pull type, small form factor (1.25 mm ferrule) Maximum stability and reliability Flat spectral response LC interface according to IEC Applications Passive optical networks (B-PON, G-PON, E-PON) Multi wavelength systems balancing Optical power receivers protection Specifications Parameter Value singlemode UPC Value singlemode APC Test method Wavelength bandwidth 1260 nm to 1360 nm and 1460 nm to 1625 nm Attenuation from 1 to 20 db, in steps of 1 db IEC Spectral tolerances ± 15% on nominal attenuation value (att 1 4 db) ± 10% on nominal attenuation value (att 5 20 db) IEC Repeatability of IL ± 0.1 db over service life Return loss > 50 db > 60 db IEC Durability min mating cycles Operating temperature 25 C to + 70 C Housing material plastic material, UL94-V0 Housing colour blue green Dimensional drawing 13.4 mm 4.5 mm 9.3 mm 4.5 mm 30 mm 35
38 Ordering Information Plug Type Attenuator LC Plug Type Attenuator LC/UPC Plug Type Attenuator LC/APC Attenuation Item no. Description 1.0dB OFA-FLC-U-010-S dB OFA-FLC-U-020-S dB OFA-FLC-U-030-S dB OFA-FLC-U-040-S dB OFA-FLC-U-050-S dB OFA-FLC-U-060-S dB OFA-FLC-U-070-S dB OFA-FLC-U-080-S dB OFA-FLC-U-090-S dB OFA-FLC-U-100-S dB OFA-FLC-U-110-S dB OFA-FLC-U-120-S dB OFA-FLC-U-130-S dB OFA-FLC-U-140-S dB OFA-FLC-U-150-S dB OFA-FLC-U-160-S dB OFA-FLC-U-170-S dB OFA-FLC-U-180-S dB OFA-FLC-U-190-S dB OFA-FLC-U-200-S Attenuation Item no. Description 1.0dB OFA-FLC-A-010-S dB OFA-FLC-A-020-S dB OFA-FLC-A-030-S dB OFA-FLC-A-040-S dB OFA-FLC-A-050-S dB OFA-FLC-A-060-S dB OFA-FLC-A-070-S dB OFA-FLC-A-080-S dB OFA-FLC-A-090-S dB OFA-FLC-A-100-S dB OFA-FLC-A-110-S dB OFA-FLC-A-120-S dB OFA-FLC-A-130-S dB OFA-FLC-A-140-S dB OFA-FLC-A-150-S dB OFA-FLC-A-160-S dB OFA-FLC-A-170-S dB OFA-FLC-A-180-S dB OFA-FLC-A-190-S dB OFA-FLC-A-200-S
39 Inline Attenuator Features Excellent uniformity Maximum stability and reliability Flat spectral response Low cost / high quality All current HUBER+SUHNER singlemode connectors can be terminated Applications Passive optical networks (B-PON, G-PON, E-PON) Telecom, CATV, FTTH Multi wavelength systems balancing Optical power receivers protection Specifications Parameter PC UPC APC Test method Wavelength bandwidth 1260 nm to 1360 nm and 1480 nm to 1580 nm Attenuation from 1 to 30 db, in steps of 1 db IEC Spectral tolerances ± 15% on nominal attenuation value (att 1 4 db) ± 10% on nominal attenuation value (att 5 20 db) IEC Return loss > 45 db > 50 db > 60 db IEC Durability Connector type Cable type min mating cycles all singlemode connector types (see last page for connector code) LSFH, Ø 2.0 mm, blue Operating temperature 25 C to + 70 C Storage temperature 40 C to + 85 C Length tolerances Cable length Tolerance (measured from ferrule tip to ferrule tip) < 1 m 0 / mm 1 to 5 m 0 / mm 5 to 10 m 0 / + 2 % 37
40 Inline Attenuator Ordering code Description OIA inline attenuator 020 attenuation db db db db db db db db db db other attenuation values upon request S tolerances S ± 15% (1 4 db); ± 10% (5 20 db) 01 wavelength and version number standard 01 cable length 01 in meters, max. 3 meters X3 cable type X3 2.0 mm cable 70/70 connector code 1st side / 2nd side see last page for connector code OIA-020-S X3-70/70 ordering code example for inline attenuator singlemode 38
41 Connector Code Connector code type 00 no connector 20 ST-HQ 22 ST-Security 24 ST-LEAN 30 FCPC 33 FCPC APC wide key 34 FCPC APC small key 40 LSA 43 LSA APC 45 MU Connector code type 70 SC 73 SC APC 8 74 SC APC 9 80 LX.5 83 LX.5 APC 85 LC 86 LC APC 90 LSH (E-2000 ) 93 LSH (E-2000 ) APC E-2000TM is manufactured under licence of DIAMOND SA, CH LOSONE 39
42 Further catalogues Cables catalogue Item no System catalogue LISA Item no Cabling systems Item no Connectors and Assemblies Item no
43 HUBER+SUHNER is certified according to ISO 9001, ISO 14001, ISO/TS and IRIS. WAIVER It is exclusively in written agreements that we provide our customers with warrants and representations as to the technical specifications and/or the fitness for any particular purpose. The facts and figures contained herein are carefully compiled to the best of our knowledge, but they are intended for general informational purposes only. Huber+Suhner AG Fiber Optics Division Degersheimerstrasse Herisau/Switzerland Tel Fax / hubersuhner.com
Plug - Type (Male/Female) Attenuators CAA series Singlemode
Plug - Type (Male/Female) Attenuators CAA series Singlemode Description: The plug-type singlemode attenuators are used directly on the ends of fiber optic jumpers prior to installation in adapters. These
SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS
Features: SINGLEMODE OR MULTIMODE FIBER OPTIC PATCHCORDS Low insertion loss < 0.2 db Excellent repeatability FC/PC, SC, ST, LC, MU, E2000 termination available Custom ferrule termination available Designed
DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)
Features: DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES) PATENT NUMBERS: CANADA 2,494,133, USA 7095931, 7295731 AND CHINA 1672073 Telcordia GR-468 qualified Available in versions for any wavelength
Reliable, Consistent, Quality
Reliable, Consistent, Quality 1-877-320-3143 www.fibertronics.com Reliable, Consistent, Quality Welcome To Fibertronics Inc. Reliability, consistency, and quality is what we put behind every Fiber optic
Fiber Optic Cable Assemblies. Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable
Fiber Optic Cable Assemblies Pigtails, Jumpers (simplex and duplex), Fanouts, Pre-connectorized Multi-Fiber Cable 1 Cable assemblies used in patch panels (Fiber Distribution Units) are an essential interface
7.4 3M No Polish Connector
Cap Fibre Splice Element Description 3M No Polish Connector (NPC) enables fast, on-site installation of 250μm and 900μm connections utilizing a one piece, pre-assembled design. The SC compatible connector
Introduction to Add-Drop Multiplexers
3 Introduction to Add-Drop Multiplexers In this chapter different channel routing technologies are reviewed, highlighting the advantages and drawbacks of the different devices and configurations. The parameters
BLINK Triple-Play Connector
An innovative optical connector tailored to residential requirements forms the basis of the HUBER+SUHNER Fiber In The Home portfolio. Increased protection against soiling of the connector end surfaces,
FIBER OPTIC ISOLATORS
Features: >0W Optical power handling capability Polarization Sensitive and Insensitive versions Product offerings over 3 000 nm wavelength range High isolation levels and low return loss Low Insertion
INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
INTERNATIONAL TELECOMMUNICATION UNION ITU-T L.52 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (05/2003) SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT
FIBER OPTIC AND COMMUNICATION PRODUCTS
FIBER OPTIC AND COMMUNICATION PRODUCTS Photonic Products Cable Assemblies Termination Boxes & Hardware Data Center FTTH World Wide Supplier #11 Test Equipment Ethernet Products Solutions for Telecommunications
Polymer Coated Fiber Cable (PCF)
Polymer Coated Fiber Cable (PCF) Panduit has introduced a Polymer Coated Fiber (PCF) to their fiber cable offering available in 50µm and 62.5µm core diameters. Along with this cable having a stronger durability
ETD Fiber Optic Products
ETD Fiber Optic Products ETD manufactures and supplies a wide range of passive fiber optic components and solutions for the European Data, Telecom and FTTX environment. ETD has worked in the Fiber Optic
Patch Cords for Data Center Applications
Applications General use of patch cords includes the interconnection of the optical fiber cable plant with opto-electronic equipment, and/or the cross-connection between cable plant segments. Pigtails
Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications
Data Sheet Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output
CISCO DWDM XENPAK. Main features of the Cisco DWDM XENPAK include:
DATA SHEET CISCO DWDM XENPAK OVERVIEW The Cisco Dense Wavelength-Division Multiplexing (DWDM) XENPAK pluggable allows enterprise companies and service providers to provide scalable and easy-to-deploy 10
Cisco SFP Optics for Gigabit Ethernet Applications
Cisco SFP Optics for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output device that plugs into a Gigabit
VARIABLE FIBER OPTIC ATTENUATORS BLOCKING PIGTAIL STYLE
VARIABLE FIBER OPTIC ATTENUATORS BLOCKING PIGTAIL STYLE Features: Rugged and compact size Wide wavelength range (from 350 to 2050nm) Singlemode, polarization maintaining and multimode fiber versions Low
Advantages of Fiber Optic Splitters in Key Applications Increase the Efficient Use of Optical Infrastructure with These Passive Components
Increase the Efficient Use of Optical Infrastructure with These Passive Components Overview Fiber optic splitters play an increasingly significant role in many of today s optical network topologies. From
Fiber Coupler Overview
Fiber Coupler Overview Couplers High channel density Pitch Reducing Optical Fiber Array (PROFA) with or without spot-size reduction: Builds on proven spot-size converting (SSC) technology - highest spatial
INTRODUCTION FIGURE 1 1. Cosmic Rays. Gamma Rays. X-Rays. Ultraviolet Violet Blue Green Yellow Orange Red Infrared. Ultraviolet.
INTRODUCTION Fibre optics behave quite different to metal cables. The concept of information transmission is the same though. We need to take a "carrier" signal, identify a signal parameter we can modulate,
spinner Measurement & Calibration equipment for network analyzers
spinner Measurement & Calibration equipment for network analyzers Edition B 2011 High Frequency Performance Worldwide www.spinner-group.com SPINNER test & calibration equipment for best measurement results
CISCO 10GBASE X2 MODULES
DATA SHEET CISCO 10GBASE X2 MODULES Figure 1. Cisco 10GBASE X2 and Xenpak Module PRODUCT OVERVIEW The Cisco 10GBASE X2 modules (Figure 1) offers customers a wide variety of 10 Gigabit Ethernet connectivity
Fiber-to-the-Home/FTTH
Hands-On Design, Installation, Maintenance & Troubleshooting Active and Passive Optical Networks Course Description This Hands-On 2-day course is designed to provide technicians with Hands-On practical
Attenuator Integrated With Input Tap (voltage control)
etmems TM Variable Optical Attenuator Integrated With Input Tap (voltage control) (US patent 8,666,218 and other patents pending) Features VOA + Tap Compact Size Low Cost High Reliability Low IL, PDL,
WDM-PON: A VIABLE ALTERNATIVE FOR NEXT GENERATION FTTP
WDM-PON: A VIABLE ALTERNATIVE FOR NEXT GENERATION FTTP AN ENABLENCE ARTICLE WRITTEN BY DR. MATT PEARSON, VP TECHNOLOGY PUBLISHED IN FTTH PRISIM MAGAZINE March, 2010 www.enablence.com Most of the Fiber-to-the-Home
Optical Fibers Fiber Optic Cables Indoor/Outdoor
presents Optical Fibers Fiber Optic Cables Indoor/Outdoor Content Optical fiber function, types optical effects applications production of optical fibre Cable - general types Indoor Indoor / outdoor Outdoor
12 Fibre MTP Jumper, MTP (non-pinned) to MTP (pinned)
1 1 9.41 115 0 Patch cables are used 143 12 Fibre MTP Jumper, MTP (non-pinned) to Patch cables are used for non -permanent connections between patch panels, transmission equipment, etc. Pre -assembled
FOCONEC. Network Connectivity & Cabling Management. Overview: Features: Brighter Future
CORDS & CABLE ASSEMBLIES Standard Simplex/Duplex Patch Cords Overview: FOCONEC supplies full series of standard simplex, duplex patch cords or pigtails, designed for interconnection or cross connection
Optical Fiber Switches
Optical Fiber Switches volume 2 contents 1 introduction 3 Piezo electrically driven optical switches 3 2 technology 4 Important parameters to characterize an optical fi ber switch 4 Multimode switches
HARTING Ethernet Cabling 8-poles Overview
Ethernet Cabling 8-poles Overview RJ45 Connectors [on page 8] System cables [on page 12] Distribution modules and Outlets [on page 17] Connectors [on page 20] System cables [on page 26] Panel feed-throughs
POLARIZATION MAINTAINING FIBER PATCHCORDS AND CONNECTORS
POLARIZATION MAINTAINING FIBER PATCHCORDS AND CONNECTORS Features: High extinction ratios of 20dB up to 40dB Low insertion losses, typically
Fiber Optics: Fiber Preparation and Fiber Connectors
Photonics Technical Note # 20 Fiber Optics Fiber Optics: Fiber Preparation and Fiber Connectors Fiber optics are used for a variety of applications in the photonics industry. Different applications require
USB 3.0 Cables. Color. Black Black Black Black Black 3021003-03 3021009-06 3021015-10 3021021-16 3021027-16. Black Black Black Black Black
USB.0 CableS USB.0 and backwards compatible for USB.0 and. Supports high speed, 480Mbps Twisted-pair construction reduces cross talk to ensure error free transfer USB A male to USB B male 00-0 007-0 0-09-
How to Determine the Right Fiber Optic Network Backup Switch For Your Application
How to Determine the Right Fiber Optic Network Backup Switch For Your Application Raymond B. Sepe, Sr. Electro Standards Laboratories 36 Western Industrial Drive Cranston, RI 02921 Telephone: 1-401-943-1164
Compact EGC Amplifier Model 93251
RF Electronics Compact EGC Amplifier Model 93251 Description The Compact Electronic Gain Control (EGC) Amplifier Model 93251 combines powerful performance with ease of use to meet the growing demands from
APPLICATION NOTES POWER DIVIDERS. Things to consider
Internet Copy Rev A Overview Various RF applications require power to be distributed among various paths. The simplest way this can be done is by using a power splitter/divider. Power dividers are reciprocal
HDO700 P FIBRE OPTIC TRANSMITTER
Timo Rantanen 18.1.2011 1(5) HDO700 P FIBRE OPTIC TRANSMITTER HDO700 P is a high performance, extremely linear externally modulated 1550 nm transmitter for HDO fibre optic CATV link. This transmitter type
HIGH POWER FREE SPACE AND FIBER PIGTAILED ISOLATORS
NEW HIGH POWER FREE SPACE AND FIBER PIGTAILED ISOLATORS Features: New! Reduced size and cost versions Reliable high power handling: As much as 80 Watts High Isolation, up to 50dB isolation possible from
Gigabit Passive Optical Networks
White Paper Gigabit Passive Optical Networks Passive Optical LAN Solutions (POLS) Theory, Design, and Installation Considerations Sean McCloud, RCDD Senior Applications Engineer, Leviton Network Solutions
CABLE ASSEMBLIES BUILDING A PRODUCT
I CABLE ASSEMBLIES BUILDING A PRODUCT The next section of your 3M Telecom Price Notebook contains a number of aids to facilitate ordering our custom Fiber Optic Cable Assembly product line. Use the charts
Fiber Optics and Liquid Level Sensors Line Guide
Fiber Optics and Liquid Level Sensors Line Guide Excellence, through every fiber. Honeywell Sensing and Control (S&C) offers fiber optic sensors manufactured with SERCOS (Serial Real-time Communication
APPLICATION NOTE POLARIZATION MEASUREMENTS
OZ OPTICS LTD. APPLICATION NOTE POLARIZATION MEASUREMENTS OZ OPTICS FAMILY OF POLARIZATION MAINTAINING COMPONENTS, SOURCES, AND MEASUREMENT SYSTEMS The information/data furnished in this document shall
Measuring of optical output and attenuation
Measuring of optical output and attenuation THEORY Measuring of optical output is the fundamental part of measuring in optoelectronics. The importance of an optical power meter can be compared to an ammeter
Light Link Series 2 LT1550. Laser Transmitter with Erbium Doped Fibre Amplifier. Description. Features
Description The Light Link Series 2 optical transmitter model employs a high performance thermally stabilised, DFB, low-chirp, isolated laser to transmit CATV signals. Operating on a specific optical wavelength
Model GS7000 4-Port Node 1 GHz with 40/52 MHz split
Model GS7000 4-Port Node 1 GHz with 40/52 MHz split The Model GS7000 4-Port Node is our latest generation 1 GHz optical node platform and utilizes a completely new housing designed for optimal heat dissipation.
Cable Assemblies. Corning Cable Systems
Corning Cable Systems OptiFit Node Assembly Photo CAPSS1721 Description As the industry s leading supplier of single-mode cable assemblies, Corning Cable Systems offers the most complete line of connectors
Attaching the PA-A1-ATM Interface Cables
CHAPTER 4 Attaching the PA-A1-ATM Interface Cables To continue your PA-A1-ATM port adapter installation, you must attach the port adapter cables. The instructions that follow apply to all supported platforms.
Splitter Solutions Brochure. www.fibrefab.co
Splitter Solutions Brochure www.fibrefab.co 2 Splitter Solutions Central Office Buildin Node / Distribution Point Underground Enclosure 1U to Zero U 1 1 for further specifications see page 4 2 for further
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers
Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers Analog Data Links Multi-Channel Contact Closures Multiplexers Digital Data Links - Contact Closures Power Supply
SMZ type 43 INTRODUCTION. The Radiall Type 43 coaxial connector range. Type 43 series - Features and benefits
INTRODUCTION The Radiall Type 43 coaxial connector range The Radiall range of Type 43 series connectors is fully approved (where applicable) to BT (British Telecom) standards as well as to British Standard
Best Practices for Ensuring Fiber Optic System Performance. David Zambrano
Best Practices for Ensuring Fiber Optic System Performance David Zambrano Inspect Before You Connect Optical Connectors in our Networks Contamination and Signal Performance Sources of Contamination Process
UniCam High-Performance Connectors, Multimode and Single-Mode
features and benefits Broad operating temperature (-40 to +75 C) Factory-polished end face Fast termination and no consumables Minimum insertion loss Performance guaranteed Utility and flexibility Consistent
TEST & INSPECTION. Featured Data Center Products. OTDRs Certification Test Kits Inspection Cleaning
TEST & INSPECTION Featured Data Center Products M310 Enterprise OTDR with TruEvent Technology Designed for Enterprise Network Testing, Troubleshooting and Documentation, the M310 with TruEvent technology
FiberBasix 50 Handheld Testers Series comprising the els-50 light source and epm-50 power meter
Series comprising the els-50 light source and epm-50 power meter 2011 GLOBAL PORTABLE FIBER OPTIC TEST EQUIPMENT MARKET SHARE LEADERSHIP AWARD The Delivering ultimate simple, CD/PMD accurate characterization
M-D,T,Q-series BroadLighter. Benchtop Broadband Light Source with Extended Bandwidth. Technical Product Specification
M-D,T,Q-series BroadLighter. Benchtop Broadband Light Source with Extended Bandwidth. Technical Product Specification Document ID: SL.RD.04.002.150723 July 2015 Revision: 001 ATTENTION ELECTROSTATIC SENSITIVE
MTS/T-BERD Platforms Very Long Range (VLR) OTDR Module
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS MTS/T-BERD Platforms (VLR) OTDR Module Key Features CWDM/DWDM ready with 1310, 1383, 1490, 1550, and 1625 nm wavelengths FTTx ready with 1310/1490/1550 nm wavelengths
Kit Highlights and Key Features
AF-OLK6 Series Fiber Optic Test kit (Data Storage Kit) Product: OLK6 Series Date: Aug:2007 Rev: 01 Description The AF-OLK6 series test kits are the complete solution necessary for the installer to test,
POLARIZATION EXTINCTION RATIO METER
POLARIZATION EXTINCTION RATIO METER Features: Measures up to 40dB extinction ratios (over specific wavelength ranges) Built in USB Communications Interface Wide wavelength range: 400 to 1000 nm for visible
Cable Assembly Solutions at the Speed of Light
Cable Assembly Solutions at the Speed of Light Peggy Kovling ACI Founder Peggy Kovling credits her extensive knowledge of the cable business, along with her abilities in customer relationship management,
SUHNER FIBEROPTIC CONNECTOR FAMILY E-2000 TM
SUHNER FIBEROPTIC CONNECTOR FAMILY E-2000 TM HUBER+SUHNER E-2000 Safety from SUHNER FIBEROPTIC The E-2000 TM is a premium connector which meets international connector standards CECC 86 275-801/802 and
Limiting factors in fiber optic transmissions
Limiting factors in fiber optic transmissions Sergiusz Patela, Dr Sc Room I/48, Th. 13:00-16:20, Fri. 9:20-10:50 [email protected] eportal.pwr.wroc.pl Copying and processing permitted for noncommercial
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431. Visit us at www.testequipmentdepot.com
Datasheet: MultiFiber Pro First MPO tester to support both Singlemode and Multimode MPO fiber testing Data centers are growing, fueled by the proliferation of media, virtualization and the need for more
palmotdr Series Handheld OTDR
palmotdr Series Handheld OTDR Most Compact High-Performance OTDR Comprehensive fiber applications, ideal for LAN/WAN/FTTx certification & trouble-shooting: SM: 1310/1490/1550, 1625/1650nm (with filter),
Optical Power Meter. Specification & User Manual
Optical Power Meter Specification & User Manual Page 1 of 9 Copyright 2011 reserves the right to modify specifications without prior notice Table of Contents 1. Description and Features.......3 2. Specification......4
3M Telecommunications Solutions for Networks. 3M Hot Melt Fibre Optic. Connectors, Kits and Accessories. Innovation
3M Telecommunications Solutions for Networks 3M Hot Melt Fibre Optic Connectors, Kits and Accessories Innovation 3M Hot Melt Connectors are among the most popular with contractors because of their reliability
The Conversion Technology Experts. Fiber Optics Basics
The Conversion Technology Experts Fiber Optics Basics Introduction Fiber optic technology is simply the use of light to transmit data. The general use of fiber optics did not begin until the 1970s. Robert
RADOX railway cables acc. to EN 50264 and EN 50306. Edition 2009
RADO railway cables acc. to EN 50264 and EN 50306 Edition 2009 Bridging our know how Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical
DIAMOND AVIM Connector
DIAMOND AVIM Connector Fiber optic connector for space applications Dr. François CALOZ, accredited laboratory Frédéric TAUGWALDER, Engineering DIAMOND SA - OCT. 2005 - ATELIER CONNECTIQUE - CNES 1 Motivation
SKY16406-381LF: 2.2-2.8 GHz Two-Way, 0 Degrees Power Divider
DATA SHEET SKY16406-381LF: 2.2-2.8 GHz Two-Way, 0 Degrees Power Divider Applications TD-LTE systems Satellite communications 2.4 GHz ISM band Features Low insertion loss: 0.3 db @ 2.5 GHz High isolation:
NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION 27 10 00 STRUCTURE CABLING TESTING
RELATED SECTIONS: NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT Section 27 00 00 General Requirements Section 27 02 00 General Communication Requirements Section 27 05 26 Grounding and Bonding for Communications
Loss & Continuity Testing with MPO/ MTP Connectors
Loss & Continuity Testing with MPO/ MTP Connectors Deployments of fiber optic systems in data centres are now using multimode ribbon fiber and typically MPO/MTP connectors, which have some very particular
Amphenol Fiber Systems International
Amphenol Fiber Systems International TACBeam M83526/20 & /21 Qualified Expanded Beam Rugged Fiber Optic Connectors M83526/20 qualified AFSI TACBeam rugged fiber optic connector About the TACBeam Connector
PURE : REliable planning of data center cabling
PURE : REliable planning of data center cabling THE PURE EFFEct: TWICE AS MANY CONNEctionS AND 15 METERS MORE CHannEL LEngtH * PreCONNECT PURE is a milestone in the development of high-end IT cabling for
Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters
Description Displayport combines the audio and video through an interface. It supports high resolution displays and multiple displays with a single cable, and increases the efficiency and bandwidth of
HP 70950B OPTICAL SPECTRUM ANALYZER
HP 71450B, 71451B, and 71452B Optical Spectrum Analyzers Technical Specifications Spectral Measurements from 600 to 1700 nm HP 70950B OPTICAL SPECTRUM ANALYZER OPTICAL INPUT The HP 71450B, 71451B, and
Fiber Optic Specifications
Fiber Optic Specifications All Fiber Optic shall be Corning Altos Single Mode OS1 Outdoor Loose Tube Gel Free Cable Corning Fiber Products only will be accepted and no substitutions or alternates will
Guide to Patch Cords. and Pigtails. www.fibrefab.co
Guide to Patch Cords and Pigtails www.fibrefab.co Established in 1992, FibreFab is a leading provider of fibre optic connectivity products used in data communications and telecommunication networks. The
SpectraTec II. Polarized Multi-Laser Source BLUE SKY RESEARCH WAVELENGTHS. The SpectraTec II
BLUE SKY RESEARCH The SpectraTec II, two wavelength laser module is a highly integrated system comprised of two lasers, individual driving and temperature control electronics, wavelength combining, and
GLOBAL COLLEGE OF ENGINEERING &TECHNOLOGY: YSR DIST. Unit VII Fiber Optics Engineering Physics
Introduction Fiber optics deals with the light propagation through thin glass fibers. Fiber optics plays an important role in the field of communication to transmit voice, television and digital data signals
AMP CO Plus Insert for Cat. 6 A Applications
Product Specification 108-93039 10/Mar/2011 Rev F AMP CO Plus Insert for Cat. 6 A Applications 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP* CO Plus
Insertion Losses of Fiber Optical Connectors
Insertion Losses of Fiber Optical Connectors Martin Strasser, Fiber Optics, HUBER+SUHNER AG, Switzerland H+S Technical Series HUBER+SUHNER Excellence in Connectivity Solutions Table of contents 1 Origins
The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT
The Effect of Network Cabling on Bit Error Rate Performance By Paul Kish NORDX/CDT Table of Contents Introduction... 2 Probability of Causing Errors... 3 Noise Sources Contributing to Errors... 4 Bit Error
Graphical User Interface Capabilities of MATLAB in Centralized Failure Detection System (CFDS)
INTERNATIONAL JOURNAL OF MICROWAVE AND OPTICAL TECHNOLOGY 128 Graphical User Interface Capabilities of MATLAB in Centralized Failure Detection System (CFDS) Mohammad Syuhaimi Ab-Rahman* and Boonchuan Ng
TIER-1/TIER-2 FIBER CERTIFICATION KITS
MaxTester 940 Fiber Certifier OLTS TIER-1/TIER-2 FIBER CERTIFICATION KITS EXFO s Fiber Certification kits cover all test requirements to perform clear, fast and first-time-right system acceptance. This
FACT OPTICAL DISTRIBUTION FRAME SYSTEM
Fiber Connectivity for Splice/Patch and Patch/Patch For almost 30 years, CommScope has led the industry with solutions such as FIST fiber management system, providing a system of fiber management from
Design Guide. SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution. www.commscope.com
Design Guide SYSTIMAX InstaPATCH 360 Traffic Access Point (TAP) Solution www.commscope.com Contents Introduction 3 How Does a TAP Work? 3 The TAP Ecosystem 4 InstaPATCH 360 TAP Module Family 4 InstaPATCH
R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements
R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements on telecommunications ports Test & Measurement Data Sheet 01.00 R&S ENY81-CA6 Coupling Network At a glance The R&S ENY81-CA6
WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor
WaveReady CFM Optical Link Monitoring System: Continuous Fiber Monitor www.lumentum.com Data Sheet The Lumentum Continuous Fiber Monitor (CFM) offers a compact, modular solution for performance monitoring
The Need for Low-Loss Multifiber Connectivity
WP_LowLoss_D_B 10/13/14 2:08 PM Page 2 The Need for Low-Loss Multifiber Connectivity In Today s Data Center Optical insertion loss budgets are now one of the top concerns among data center managers, especially
Fakra. Coaxial connectors. DC 6 GHz
C-Blue D-Bordeaux GPS application GSM/Mobil Phone The FAKRA (Automobile Expert Group) has therefore defined a standardised connector system for the various communication applications in cars. Our FAKRA-compliant
Bandwidth analysis of multimode fiber passive optical networks (PONs)
Optica Applicata, Vol. XXXIX, No. 2, 2009 Bandwidth analysis of multimode fiber passive optical networks (PONs) GRZEGORZ STEPNIAK *, LUKASZ MAKSYMIUK, JERZY SIUZDAK Institute of Telecommunications, Warsaw
FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems
Data Sheet FOMi-E3, FOMi-T3 Extend the range of E3, T3 or HSSI services over fiber optic cables up to 110 km (68 miles) Transparently transmit E3, T3 or HSSI signals over multimode and single-mode fiber
AC3200 INTELLIGENT BROADBAND AMPLIFIER
Kari Mäki 9.4.2013 1(7) AC3200 INTELLIGENT BROADBAND AMPLIFIER AC3200 is the latest leading-edge addition to AC family with extended frequency and gain ranges and integrated electrical controls in both
Tapping Technology. Just the Facts about the Pretium EDGE Tap Module
Just the Facts about the Tap Unlike most passive tap devices, the Tap is fully integrated into the structured cabling physical plant, rather than added as a separate component into the link. This integrated
SOURIAU s discrete wire sealing
SOURIAU s discrete wire sealing Description Using proven grommet technology from SOURIAU s extensive knowledge of harsh environments, the UTO & UTS connectors with grommet garantie a discrete wire sealing
Fibre Channel Fiber Cabling
OVERVIEW This paper will discuss the Fibre Channel standards for fiber cables at both 1Gb and 2Gb speeds, and also some discussion of departures from standard. Items discussed will be cable types, plug
LAP NODO ÓPTICO 2/4 SALIDAS WT-8604JL
2/4 SALIDAS WT-8604JL Latin American Power. CABA, Argentina. www.latinamericanpower.com 1 WT-8604JL OPTICAL RECEIVER 1 - DESCRIPTION WT-8604JL is our new high-class 4-way output CATV optical receiver.