MGE EPS /400/500 kva High availability, high performance

Similar documents
Galaxy VM. Three-phase power protection. schneider-electric.com

MGE Galaxy /200/250/300/400/500 kva Power efficiency for business continuity

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

Re-defining the utility-scale inverter

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

MAJORSINE Power Inverter

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

PX100 MBP with Configurable Distribution

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

UPS system for emergency lighting and smoke extraction

Phase Modular Finally the benefits of Modular ups are for all

PowerGem Pro Uninterruptible Power Supply

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

ABB PSPS Erich Steinmann; Generator control-2013

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

Chloride 80-NET from 60 to 500 kw. Secure Power for Mission Critical Applications

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

4.0 UPS dedicated to ICT for unmatched energy savings

Thyristor-controlled power supplies and battery chargers

RIELLO ELETTRONICA. Master HP

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

TOSHIBA G /100/160/225 kva

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Liebert NXC from 10 to 200 kva

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Diesel Engine Driven Generators Page 1 of 6

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Satcon Solstice 100 kw System Solution

SG Series UPS kva. high efficiency systems

APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog

TLE Series. Product Description kva / 400Vac / S1 KEY BENEFIT APPLICATIONS FEATURES

Uninterruptible Power Supply

Galaxy 7000: Unitary Specification guide: Single UPS, three-phase, 160 to 500 kva

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

Secondary Unit Substations

Maintenance Service 1.1 ANNUAL PREVENTIVE MAINTENANCE 1.2 ON-SITE REMEDIAL SERVICES

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Power Quality. Uninterruptible Power Supply

Schneider Electric GALAXY VM Data Center Grade Three Phase Uninterruptible Power Supply Guide Specifications kva UPS

Power Management Module 2. Installation

Healthcare Secure Power Solutions

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

LAP ENERGIA PARA DATACENTERS

GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Considering the effects of UPS operation with leading power factor loads

SECTION STATIC UNINTERRUPTIBLE POWER SUPPLY SYSTEM

Line Reactors and AC Drives

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

Top 12 Questions to Consider When Choosing UPS Systems for Network/Server Applications

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

32VFD Variable Frequency Drives for Centrifugal Chillers

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理. Schneider Electric - Division - Name Date

Schneider Electric Critical Power & Cooling Services. Expertise, service, and support for building, industry, power, and data center infrastructure

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

SWITCHGEAR. EGP Switchgear

Tough Decision: On-Line or Line-Interactive UPS?

Dell Smart-UPS 1,500 3,000 VA

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Smart-UPS 3 Phase And MGE Galaxy 3500

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

WIND Power Technology: IMD Integrated Motor Drive

Product Data Bulletin

Medium Voltage Motor Control Assemblies

Liebert 80-eXL from 100 to 1200 kw. Enhanced Design and Improved Efficiency

Eaton 93PM UPS Where aesthetics meet intelligence.

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

Atlas Copco Generators

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Inverter / Charger Installation General Operations and AC and DC Connections

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

IT White Paper IP TELEPHONY AND RELIABILITY: PROTECTING MISSION-CRITICAL PHONE SYSTEMS FROM POWER THREATS

POWER. Your Partners in Availability POWER

Specification CyberWave UPS Ver /01/00

The Quest for Energy Efficiency. A White Paper from the experts in Business-Critical Continuity

Transcription:

MGE EPS 7000 300/400/500 kva High availability, high performance 300 500 kva robust three-phase power protection with adaptability to meet the unique requirements of medium to large data centers, buildings, and critical industrial processes Flexible and very adaptable Strong electrical features Intuitive monitoring Parallel capabilities Synchronization to external source High availability architecture components

Features and benefits MGE EPS 7000 features High availability, high performance The MGE EPS 7000 is the facility manager s top UPS choice with full front access and all critical serviceable components reachable within minutes, not hours. These UPS modules allow IT and facilities managers to respond to increasing demands placed on power infrastructure in growing facilities by offering N+1 capabilities. The EPS 7000 was the first in the industry to incorporate a 100 percent-rated static switch on output of UPS inverter with no mechanical contactors, which can age and weaken during UPS operation. Energy efficiency is a key feature for the EPS 7000 with up to 94 percent system efficiency at full load. EPS 7000 provides pure flexibility, with auxiliary equipment such as paralleling gear, external maintenance bypass, critical bus synchronization, bottom entry cabinets, and distribution to meet specific site configuration while maximizing efficiency and output power quality. MGE EPS 7000 Availability Higher power density Manageability Adaptable configurations Digital power quality inverter Using a unique technology called Digital Power Quality Management (DPQM), the inverter maintains precision voltage regulation under all operating conditions. The key to the superior performance lies in the speed and resolution of the waveform, which is generated by up to eight pulses per millisecond, allowing the waveform to be tightly controlled. The waveform is constantly compared to a real time reference sine wave. If the sine wave deviates from the reference sine wave, the gain of the inverter output is adjusted, creating a correction pulse maintaining a power quality envelope that is +/ 1 percent of a perfect sine wave. A free switching frequency accelerates during periods of major variations for better regulation. By optimizing the switching frequency, the EPS 7000 is also able to minimize switching losses and maintain a high efficiency level even at lower loads. Digital power quality logic Digital wave form correction Real-time reference sine wave Feedback on wave form quality Low kvar filter Redundant parallel logic Integrated output isolation transformer Serviceability Front access design Modular rectifier and inverter sub-assembly Intuitive standard graphical display Economy Low installation costs Reduced footprint Low CapEx solution Simplified installation Top entry standard Comprehensive installation procedures Approvals UL1778 CUL Advanced battery management Remote power monitoring Built-in modbus Options galvanic isolation Battery cabinet Bypass cabinet Bottom entry cabinet Typical applications Data Center Industrial Healthcare Petrochemical Utility Support and service Extended warranty plans Worldwide field service organization Another benefit of the high-resolution control topology is that harmonic distortion reflected from the loads is practically eliminated. UPS input filter technology The technology used to maintain the input power factor and avoid leading PF loads is an important consideration. Many other large UPS modules rely on disengaging the input filter capacitors with a contactor at lower loads where the UPS risks becoming a leading PF load. ing capacitors will create large notches and disturbances on the utility bus. Furthermore, the system is relying on a mechanical contactor. Our system is based strictly on a solid state inductor assembly balancing the effect of the capacitors a safe and reliable technology. Quality band with variations <1% voltage curve Free-frequency switching Up to 8 commutations per millisecond Filter Charger Available project management services 2 MGE EPS 7000 3 MGE EPS 7000

MGE EPS 7000 features MGE EPS 7000 options Solid state disc SCR transfer switch EPS 7000 uses large hockey puck SCRs in its static bypass. The ability to clear faults safely is dictated by the capacity of the static bypass switch. Because these SCRs can tolerate quick fault currents over 20 times that of the UPS rating, they can safely use the fault clearing power of the utility to clear the fault without any damage to the UPS. Many other UPS modules typically use lower current brick type SCRs on their static switches that are only momentary rated and rely on an overlap contactor to carry the current. Because fault current rises so quickly, it can often exceed the rating of these momentary SCRs before the contactor has a chance to engage. The fault clearing capability of the UPS is regulated by capacity of the static bypass switch. The EPS 7000 uses robust disc SCR static bypass switch which is able to clear instantaneous fault current over 20 times the nominal rating of the UPS. The EPS 7000 bypass is 100 percent continuous duty rated, making it more reliable than systems that pair smaller, momentary bypass switches. Fault tolerant faults are common events on any UPS system. Even a small downstream device fault may take four or five cycles before a distribution circuit breaker opens. This means that the UPS module must be capable of clearing the fault. IGBTs (the transistors) used in the inverters simply are not designed to sustain faults. The key to managing faults is to firstly protect the inverter by current limiting it from fault conditions and then safely make a seamless transfer to utility via the static bypass switch. The result is that the load will stay protected and the UPS will remain intact. New standard graphical user interface The Advanced Graphical Interface for the EPS 7000 UPS system features a 12 in. high contrast TFT LCD touch screen. Delivering features including animated mimic diagrams, alarm event logs, trending, component level status and more, the interface presents UPS status information in an easy to read graphical format. Guided by a clear menu, users can navigate through all screens to explore system level information on multi-module systems drilling right down to module and component level information. Operator procedures simplify the use of the UPS, contributing to an overall increase in reliability by mitigating user errors. isolation transformer EPS 7000 has the capability to include a matching input isolation transformer cabinet within the UPS lineup. Integrating the transformer directly into the lineup module provides all the benefits of galvanic isolation, including a very robust buffer between the utility and the critical load. Options isolation transformer distribution External maintenance bypass Bottom cable entry Remote alarm status panel Seismic anchors SNMP/Network management card Battery monitoring Continuous duty and momentary duty static switch cabinets (SSC) Critical bus synchronization module Battery disconnect EPS 7000 single module Source 2 Source 1 CB Filter RS232/RS485 JBus Interface EPS 7000 parallel module with System Cabinet UPS 1 This feed required for 3CB Maintenance Bypass only This feed required for 2CB Maintenance Bypass only Rectifier Inverter Q4S Seismic compliancy EPS 7000 modules are compliant with IBC 2006 (International Building Code and OSHPD). Proper sizing and placement of seismic brackets is imperative in adequately restraining equipment against seismic effects. EPS 7000 seismic mounts and restraints are designed to provide strength during an event. EPS 7000 installation drawings will guide you in proper installation. Maintenance Bypass Cabinet This feed required for 3CB Maintenance Bypass only This feed not required with 3CB Maintenance Bypass Rectifier Inverter Single or dual input configurations available QF1 Battery Disconnect Q3BP Maintenance Bypass board Bypass Distribution board Q3BP Q4S Critical Load Momentary Continuous Duty UPS 2 Filter System Cabinet (SSC) To Critical Load board RS232/RS485 JBus Interface Remote Alarm Panel Remote Summary Alarm Panel Note: SSC can parallel up to six modules up to 4000 amps 4 MGE EPS 7000 5 MGE EPS 7000

Specific technical advantages StruxureWare for Data Centers Software Suite Battery management Batteries represent a significant investment in any UPS system often half the cost. They also have the highest risk of failure of any component. The EPS 7000 s battery management system performs two critical functions. First, it collects all the relevant inputs to display the most accurate time remaining. Then by incorporating key details such as battery temperature, the EPS 7000 rectifier continually optimizes the charge voltage to maximize battery life. Full output voltage regulation over entire range of the battery The EPS 7000 uses a 480 VDC bus. As a result of the DC bus closely matching the AC output voltage, the UPS is able to maintain the output voltage regulation over the whole operating range of the battery. Some UPS modules that use lower DC busses (using fewer batteries in series) may experience decaying output voltage as the battery voltage/dc bus drops during discharge. This means that the EPS 7000 UPS will be able to maintain perfect voltage regulation over the full range of the battery. Energy efficient for significant cost savings The energy efficiency of the EPS 7000 is extremely high especially at lower loads where redundant UPS modules operate. The result is often energy cost savings that usually exceed the cost of the UPS module in as little as three to five years compared to leading brands. Core efficiency up to 94 percent High efficiency maintained over lower load levels where most UPS modules operate Potential energy cost savings that can equal the value of the UPS in as little as a few years 100% Energy savings Non-optimized IGBT UPS efficiency 93% APC by Schneider Electric UPS units and secure power systems are a core component of any architecture designed for highly critical applications, such as data centers, industry environments, infrastructure, and buildings. Intelligent energy management of these systems is enabled by Schneider Electric EcoStruxure integrated hardware and software system architecture. StruxureWare software applications and suites are a key element of the EcoStruxure architecture. StruxureWare software helps maximize system reliability and optimize operational efficiency. StruxureWare for Data Centers software collects and manages real-time information about assets, resource use, and operation status throughout the data center life cycle. This data center infrastructure management (DCIM) software fully integrates the MGE EPS 7000 UPS. With full system visibility, managers can monitor and apply this information in order to optimize data center performance to meet IT-, business-, and service-oriented goals. A Comprehensive Portfolio of Services Schneider Electric Critical Power & Cooling Services (CPCS) provides the highest quality services and solutions by trained and trusted professionals. Our world-class services offer a smart way to build, operate, and maintain your critical applications, ensuring the right people, in the right place, at the right time. 0% 35/40% 100% Assembly and Start-Up Service Assembly and Start-Up Service by a certified Field Service Engineer (FSE) ensures full factory warranty coverage. A Schneider Electric certified installation of your solution ensures your equipment is properly and safely configured for optimal performance. This service features a standard eight-hour, five-day response time, with upgrades available for offbusiness hours. Advantage Plans Flexible service packages offer hassle-free system maintenance to improve uptime at a predictable cost. These packages provide your system with the care it needs to operate most efficiently while minimizing downtime. The Advantage Plus, Prime, Ultra, and Max are full-service packages that include technical support, preventive maintenance, quick on-site response, and remote monitoring. Response time upgrades are available. Preventive Maintenance Preventive Maintenance on-site examinations of your critical systems are designed to prevent problems before they occur and keep your system running at maximum efficiency. On-site Warranty Extension Service In the event of a system issue, an FSE will arrive on site by the next business day to isolate, diagnose, and correct the problem in as little time as possible, minimizing downtime. Upgrades to even faster response times are available. Remote Monitoring Service (RMS) RMS is an economical and easy-to-use Webbased service that lets you quickly respond to environmental or system changes. Trained technicians provide secure 24-hour monitoring of your physical infrastructure to diagnose and resolve problems before they become critical. 6 MGE EPS 7000 7 MGE EPS 7000

Technical specifications Rated power (kva/kw) 300/270 400/360 500/450 300/270 400/360 500/450 Normal AC input voltage (V) 480 (+/- 10%, 3ph 3 wire + ground) 600 (+/- 10%, 3ph 3 wire + ground) Frequency (Hz) 60 Hz +5% Power factor 0.9 THDI (full load) 300 kva (10%), 400 kva (8%), 500 kva (7%) Nominal input current (A) 371 508 656 322 441 569 Maximum input current (A) 453 590 738 404 523 652 Bypass AC input Voltage (V) +/- 10% UPS output voltage (3ph, 3/4 wire + ground) Frequency (Hz) 60 Hz (+/- 0.25 Hz up to 2.0 Hz) Nominal bypass current (A) 361 481 601 289 385 481 voltage (V) 480 (3ph 3 or 4 wire + ground) 600 (3ph 3 or 4 wire + ground) Power factor 0.9 Frequency 60 Hz UPS output current (A) 361 481 601 289 385 481 Battery DC current (max) 721 962 1,195 721 962 1,195 Overall efficiency System efficiency (full load) 94% 93% 93% 92.5% Full load heat rejection (BTUs) 59,400 78,100 110,750 65,000 86,000 112,000 Environmental conditions Acoustical noise level 75 dba at 5 feet Operating temperature 0 C to 40 C (32 F to 104 F) Non-operating -20 C to +45 C (-4 F to 113 F) Relative humidity 0 to 90% (non-condensing) Dimensions and weights UPS module (lb.) 6,900 UPS module (W x H x D) 69 x 82 x 39 in. Maintenance bypass cabinet (lb.) 540 Maintenance bypass cabinet (W x H x D) 22.75 x 82 x 39 in. Bottom entry cabinet (lb.) 190 Bottom entry cabinet (W x H x D) 14 x 82 x 39 in. Transformer cabinet (lb.) 3,600 600 V input transformer cabinet (W x H x D) 44.75 x 82 x 39 in. NOTE: Due to continued product enhancements, specifications are subject to change without notice. Data above is for reference only - not construction. Schneider Electric assumes no liability for damages as a result of any data errors or omissions in this document. Consult product guide specifications and installation drawings for further details. 2013 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. email: esupport@apc.com 132 Fairgrounds Road, West Kingston, RI 02892 USA 998-5823