ILHT Series - F rated centrifugal fans

Similar documents
CADB and CADT-D / DI / DC Series

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

ICQ Series - square centrifugal

Surface Technology. Centrifugal Fan GMD

systemair Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair

Transformer oil cooler ALFA A02

RFHD. ROOF CENTRIFUGAL FANS WITH ATEX CERTIFICATION CEE ExII2G Ex d. According EU Regulation

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

TFSR & TFSK Roof Fans

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

RPV - RP - RA air handling units

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

UDSA - UDSBD unit heater

ECOCIAT. Domestic hot water heat recovery unit

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Air Comfort. Technical Catalogue > Roof Fan STOF

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

CRN A-F-G-E-HQQE 3x400D 50 HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Ventilation Solutions Kitchens. fantech

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Application. Design. Structure. Acoustics

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series


8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Centrifugal Fans direct driven with scroll. Issue 1.3 November 2012

Vertical Multistage Centrifugal Electric Pumps SV Series NEW LASER TECHNOLOGY

Commercial Gas Furnace Upflow

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

FIRE DAMPER APPLICATION GUIDE

Series description: Wilo-Drain TC 40

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

product application guide

Standard offering (pumps)

Multistage high-pressure multistage centrifugal pumps

8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) rpm

EC-fans. Energy efficient and environmentally friendly

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

CRK A-W-A-BUBV

How To Build A T7 Rack For Information Technology

Mechanical Rooftop Custom Capabilities

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

FAN & BLOWER CENTRIFUGAL FANS

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Cooking at the Speed of light!

How To Save Energy On A Power Supply

Fire. The Fire Installers Mate. A guide to fire alarm systems design

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

SPP Pumps Inc. Atlanta

squrboxbox heat recovery squrboxbox I technical information

CEILING CASSETTE FAN COIL UNIT

TURBOWENT TULIPAN - rotary chimney cowl Ø150

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Cool Design for Homes and Offices

SUNON SPECIFICATION FOR APPROVAL

CE Marking to BS EN

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

KTZ data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

Low Voltage Switchboards The Best Technical Solution for Your Ship

Element D Services Heating, Ventilating, and Air Conditioning

EC medium pressure axial fans. The effi cient system solution.

Energy Saving ECM Motors and Fans Ventilation Catalogue

Chapter 3.5: Fans and Blowers

The CLIPPER Solutions

Fire Pump Plan Review March 2010

The ventilation of the future.

Thyristor-controlled power supplies and battery chargers

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

Data Center Cooling. The engineer s choice

Conlift1, Conlift2, Conlift2 ph+

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

We have been working in an ideal climate for thirty years.

DIGITUS Network & Server Cabinets. UNIQUE Series

sealed close coupled pumps

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

JET FANS CAR PARK VENTILATION SYSTEMS F400 - F300 - F200. EN Powered smoke and heat exhaust ventilators for use in Construction Works

KONRAD. Hybrid Fancoil Series

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

lifting stations motralec

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

IEC Connectors. Introduction

How To Test A Fume Cupboard

Installation, operation and maintenance manual TX 35A

Condensing unit type EPSILON-ECHOS LE Technical information manual

PIEZOMETER AIRFLOW MEASURING RING

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Transcription:

EN 484-489 ILHT.qxd 13/1/08 20:03 Página 484 IN-LINE DUCT FAN ILHT Series - F400 120 rated centrifugal fans Officially approved to EN12101-3 80 C CONTINUOUS operation Range of direct-drive rectangular in-line fans designed for smoke extraction in fire conditions and certified F400 120 (CE marked). All models are suitable for air stream temperature up to 80ºC. The casings are manufactured from high grade robust galvanised sheet steel. Due to the flexible design and configuration the ILHT units can be installed in any position both horizontal or vertical. All fans incorporate a centrifugal backward curved impeller manufactured from galvanized sheet steel. Available, depending upon the model, with three phase motors in 4, 6, 8, 4/6, 4/8, 6/8 or 6/12 poles. 0 019082 603078 Motors All the motors are IP55, Class F insulation. Electrical supply: Three phase 230/ 400V-50Hz, 1-speed motors. Three phase 400V-50Hz, 2-speed motors. (See characteristics chart). Easy to install A P P L I C A T I O N S On request Single phase motors. Speed controllable motor by voltage. Double thickness (double skin) panels internally lined with sound and thermal fibre glass insulation (25 ). Fixings fitted to ease the Installation rkings Coercial and industrial kitchens Welding installations 80 C CONTINUOUS operation VERSATILE DESIGN Interchangeable side panels, to produce the different possibilities of air extraction and supply. 484

EN 484-489 ILHT.qxd 13/1/08 20:03 Página 485 Technical characteristics Before installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequency etc) match those of the intended electrical supply. Speed Maximum Maximum Speed Motor Maximum Maximum Sound absorbed absorbed power absorbed air volume pressure power current current level Model (r.p.m.) (kw) (A) 400 V (r.p.m.) (kw) (A) 400 V m 3 /h db(a)* 4 POLES - 1 SPEED ILHT/4-035 1415 0,55 1,4 3500 56 ILHT/4-050 1415 0,75 1,7 5000 59 ILHT/4-060 1420 1,5 3,2 7000 62 ILHT/4-065 10 2,2 4,6 10000 64 6 POLES - 1 SPEED ILHT/6-035 940 0,25 1,0 2333 50 ILHT/6-050 940 0,25 1,0 3333 ILHT/6-060 940 0,37 1,2 4667 53 ILHT/6-065 930 0,75 2,0 6667 56 ILHT/6-085 950 1,1 2,8 8400 58 ILHT/6-110 940 2,2 5,4 12500 60 ILHT/6-140 960 3 6,8 15000 63 ILHT/6-190 955 5,5 12,2 19000 64 8 POLES - 1 SPEED ILHT/8-065 700 0,37 1,4 5000 ILHT/8-085 700 0,55 1,9 6300 52 ILHT/8-110 700 1,1 3,4 9375 54 ILHT/8-140 695 1,5 4,0 11250 57 ILHT/8-190 720 3 7,2 14250 58 ILHT/4/6-050 1415 0,75 2,0 940 0,25 1,3 5000 59 ILHT/4/6-060 1420 1,5 3,7 940 0,37 1,7 7000 62 ILHT/4/6-065 1445 3 6,8 975 1 4,1 10000 64 ILHT/4/8-035 1360 0,6 1,9 690 0,15 0,9 3500 56 ILHT/4/8-050 1380 0,8 2,0 690 0,2 1,0 5000 59 ILHT/4/8-060 1390 1,6 4,1 700 0,4 1,8 7000 62 ILHT/4/8-065 1415 2,8 6,1 715 0,7 2,4 10000 64 ILHT/6/8-035 940 0,55 2,1 700 0,14 1,2 2333 50 ILHT/6/8-050 940 0,55 2,1 700 0,14 1,2 3333 ILHT/6/8-060 930 0,55 2,1 690 0,14 1,2 4667 53 ILHT/6/8-065 950 1,1 3,6 720 0,55 2,5 6667 56 ILHT/6/8-085 965 1,1 3,6 720 0,55 2,5 8400 58 ILHT/6/8-110 985 3,0 8,0 725 0,75 3,8 12500 60 ILHT/6/8-140 960 4,0 11,3 695 1,1 4,8 15000 63 ILHT/6/12-110 950 4 12,6 470 1,0 5,1 12500 60 ILHT/6/12-140 950 4 12,6 470 1,0 5,1 15000 63 ILHT/6/12-190 975 5,5 14,1 480 1,1 5,4 19000 64 *Measured at 6 m from the inlet side. 4/6 POLES - 2 SPEED 4/8 POLES - 2 SPEED 6/8 POLES - 2 SPEED 6/12 POLES - 2 SPEED 485

EN 484-489 ILHT.qxd 13/1/08 20:03 Página 486 Dimensions () Mounting with the motor in horizontal position Motor Tapa motor cover Casing Soporte support de caja Anti-vibration Soportesmounting antivibratorios Accessory Accesorio Model A B C D E L M N P Q Weight (kg) 035 700 600 780 850 675 727 927 1038 1122 928 70 050 700 600 780 850 675 727 927 1038 1122 928 90 060 800 700 880 950 775 827 1027 1182 1266 1028 110 065 800 700 880 950 775 827 1027 1182 1266 1028 135 085 900 800 1015 1085 875 962 1162 1330 1414 1175 145 110 900 800 1015 1085 875 962 1162 1330 1414 1175 160 140 1000 900 1115 1185 975 1062 1262 10 14 1275 175 190 1100 1000 1215 1315 1075 1162 1362 1530 1614 1375 210 Mounting with the motor in vertical position Motor Tapa motor cover L M Anti-vibration Soportes mounting antivibratorios Accessory Accesorio Casing Soporte support de caja Model A B C D E K L M N P Q Weight (kg) 035 700 600 780 850 675 722 587 787 1038 1122 1005 70 050 700 600 780 850 675 722 587 787 1038 1122 1005 90 060 800 700 880 950 775 822 687 887 1182 1266 1155 110 065 800 700 880 950 775 822 687 887 1182 1266 1155 135 085 900 800 1015 1085 875 934 822 1022 1330 1414 1345 145 110 900 800 1015 1085 875 934 822 1022 1330 1414 1345 160 140 1000 900 1115 1185 975 1034 922 1122 10 14 1445 175 190 1100 1000 1215 1315 1075 1134 1022 1222 1530 1614 1545 210 486

EN 484-489 ILHT.qxd 13/1/08 20:03 Página 487 Performance curves Q = Air volume in, m 3 /hr and m 3 /s. Pe = Static pressure in and. Dry air at 20ºC and 760 Hg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, rt 1; AMCA 210-85 and ASHRAE -1985. 47 50 db(a) db(a) 29 38 31 39 35 54 32 40 36 44 40 48 56 54 55 db(a) 58 db(a) 33 41 36 45 40 48 59 35 39 47 62 42 44 db(a) 50 55 db(a) 56 38 44 46 57 Pressure sound level measured at 6m distance with free ducted inlet and outlet. 487

EN 484-489 ILHT.qxd 13/1/08 20:03 Página 488 Performance curves Q = Air volume in, m 3 /hr and m 3 /s. Pe = Static pressure in and. Dry air at 20ºC and 760 Hg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, rt 1; AMCA 210-85 and ASHRAE -1985. 52 52 55 db(a) 56 db(a) 45 48 45 40 46 58 40 44 47 52 59 Pressure sound level measured at 6m distance with free ducted inlet and outlet. Mounting accessories Mounting support Vertical mounted, discharge protection guard Model Casing support 035 ILHT-SOPORTE - 035 050 ILHT-SOPORTE - 035 060 ILHT-SOPORTE - 060 065 ILHT-SOPORTE - 060 085 ILHT-SOPORTE - 085 110 ILHT-SOPORTE - 085 140 ILHT-SOPORTE - 140 190 ILHT-SOPORTE - 190 Rectangular duct connection flange Model Flanges 035 ILHT-BRIDA - 035 050 ILHT-BRIDA - 035 060 ILHT-BRIDA - 060 065 ILHT-BRIDA - 060 085 ILHT-BRIDA - 085 110 ILHT-BRIDA - 085 140 ILHT-BRIDA - 140 190 ILHT-BRIDA - 190 Model Vertical protection guard K L I M 035 ILHT-VISERA-V- 035 140 605 705 0 050 ILHT-VISERA-V- 035 140 605 705 0 060 ILHT-VISERA-V- 060 140 705 805 550 065 ILHT-VISERA-V- 060 140 705 805 550 085 ILHT-VISERA-V- 085 140 806 906 605 110 ILHT-VISERA-V- 085 140 806 906 605 140 ILHT-VISERA-V- 140 140 906 1006 665 190 ILHT-VISERA-V- 190 140 1006 1106 725 488

EN 484-489 ILHT.qxd 13/1/08 20:03 Página 489 Horizontal mounted, discharge protection guard Model Horizontal protection guard K N n P 035 ILHT-VISERA-H- 035 140 705 605 550 050 ILHT-VISERA-H- 035 140 705 605 550 060 ILHT-VISERA-H- 060 140 805 705 605 065 ILHT-VISERA-H- 060 140 805 705 605 085 ILHT-VISERA-H- 085 140 906 806 665 110 ILHT-VISERA-H- 085 140 906 806 665 140 ILHT-VISERA-H- 140 140 1006 906 725 190 ILHT-VISERA-H- 190 140 1106 1006 780 Flexible rectangular flanged duct connector Model Rectangular flexible connector L I R 035 ILHT-ACOP-RECT- 700X600 605 705 160 050 ILHT-ACOP-RECT- 700X600 605 705 160 060 ILHT-ACOP-RECT- 800X700 705 805 160 065 ILHT-ACOP-RECT- 800X700 705 805 160 085 ILHT-ACOP-RECT- 900X800 806 906 160 110 ILHT-ACOP-RECT- 900X800 806 906 160 140 ILHT-ACOP-RECT- 1000X900 906 1006 160 190 ILHT-ACOP-RECT- 1100X1000 1006 1106 160 Motor cover (for outdoor mounted installations) Model Motor protection guards 035 ILHT-TAPA-MOTOR-V- 035 050 ILHT-TAPA-MOTOR-V- 035 060 ILHT-TAPA-MOTOR-V- 060 065 ILHT-TAPA-MOTOR-V- 060 085 ILHT-TAPA-MOTOR-V- 085 110 ILHT-TAPA-MOTOR-V- 085 140 ILHT-TAPA-MOTOR-V- 140 190 ILHT-TAPA-MOTOR-V- 140 ISA-ILHT anti-vibrations support. (Set of 4 rubber supports) 489