TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans
|
|
- Annabelle Wells
- 8 years ago
- Views:
Transcription
1 IN-LINE MIXED LOW DUT ANS ultra-quiet Series (16 to 1 models) Low profile Mixed-flow fans with sound-absorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD-35, TD-5, TD-8 and TD-1 models). Manufactured in plastic material, with a specifically designed internal skin to direct the sound waves in the right angle for them to be captured by the sound-absorbent material (1). itted with rubber gaskets on the inlet and outlet to absorb vibrations, a body that can be dismantled. onnection box can be rotated 36º, to facilitate easy connection of the power cable. Motors Speed controlable 3 V 5 Hz motor, of two speed motors. Motors are IP44, class, with ball bearings and safety thermal overload protection. (1) Except the TD-16 SILENT, that is fitted with the special floating motor system patented by S&P. Series (13 and models) NEW Additional information MIXVENT TD-T models fitted with a Run-On- Timer adjustable within 1 and 3 minutes and one-speed motor not suitable for speed control. Three phase models adjustable by inverter control. Low profile Mixed-flow fans with soundabsorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD- model). onstructed from sheet steel with epoxy polyester paint, acoustic insulation (MO) glass fibre, within outer shell. Aerodynamic inlet to improve air flow and reduce sound. Detachable fan unit without demounting duct connections. External terminal box IP55. Removeable fan body with speed motor, single phase 3V-5/6Hz speed controlable, IP44, lass, external rota aluminium motor with capacitor and thermal protection. Additional information The models offer solutions to ventilation problems, especially in places where people work and low sound level is required.
2 5 t o 1 m o d e l s Low profile Low noise level 1 The low profi le of the fans makes them the most effective Sound waves produced inside the TD, are directed through the solution for installations where the space of installation is limited such perforated inner skin as false ceilings. material Easy maintenance onnection box rotated 36º 1 and absorbed by the layer of sound-absorbent. lexible washers Support bracket i-material support brackets, onnection box can be rotated i-material inlet and outlet Support bracket for installing on which in addition to simplifying 36º, to facilitate easy connec- incorporating a flexible washer to a wall or ceiling, incorporating installation, serve as joint seals. tion of the power cable. facilitate installation and absorb twin-material support brackets vibrations. for the motor section that absorbs vibration. Easy to mount Models with Run-On-Timer Remove the fan body Remove the terminal box lid onnect electrical supply tightening the clamps 1 6 MODEL Silent-elastic-blocks TD-16/1N SILENT model offer very low noise level, with a motor mounted on silentelastic-blocks which absorb the vibrations -T models (from 5 to 1 models) are fitted with an adjustable timer between 1 and 3 minutes and are supplied with a one-speed motor not suitable for speed control Remount the fan body by Loosen and open clamps on both sides
3 1 3 a n d m o d e l s Low profile - compact Easy maintenance Low profile fans TD-13/5 SILENT and TD-/315 SILENT are ideal for installations where space is very small, as in false ceilings. Detachable fan unit for maintenance, or cleaning, without demounting duct connections. Low noise level Support bracket IP55 remote terminal box Acoustic insulation (MO) glass fibre Outer shell Aerodynamic inlet to improve air flow and reduce sound Attenuating perforated skin Suitable for wall or ceiling mounting. ixing brackets to the motor-body included. Easy installation and connection.
4 Technical characteristics Model Speed (r.p.m.) Maximum absorbed power (W) Maximum absorbed current (A) Duty at free discharge (m 3 /h) Maximum operating temp. (º) Sound pressure level* (d(a)) Ø Duct (mm) Weight (Kg) TD-16/1 N SILENT 5 5 1,16, / ,4 TD-5/1 SILENT ,11, / ,4 TD-35/15 SILENT ,13, / ,94 TD-5/15-16 SILENT ** ,, / /16 6, TD-8/ SILENT ,45, / ,7 TD-1/ SILENT 5 1 1,5, /+6 1 8,7 TD-13/5 SILENT ,83, / , TD-/315 SILENT ,8, / , * Sound pressure level radiated at 3 m at free air conditions with rigid ducts at the inlet and at the outlet. ** It provides an additional rubber gasket for installation in 16 mm ducts. Model Speed (r.p.m.) Maximum absorbed power (W) Maximum absorbed current (A) Duty at free discharge (m 3 /h) Maximum operating temp. (º) Sound pressure level* (d(a)) TD-5/1 SILENT-T 4, ,4 TD-35/15 SILENT-T 5 3, ,94 TD-5/15-16 SILENT-T 5 5, /16 6 TD-8/ SILENT-T 78 95, ,7 TD-1/ SILENT-T 5 1, ,7 * Sound pressure level radiated at 3 m at free air conditions with rigid ducts at the inlet and at the outlet. Ø Duct (mm) Weight (Kg)
5 Dimensions (mm) TD-16/1 N SILENT 5 to 1 5 to 1 A Ø D Ø E G H TD-5/ TD-35/ TD-5/15-16* TD-8/ TD-1/ * It provides an additional rubber gasket for installation in 16 mm ducts. 13 and 13 and A D E G H TD-13/5 SILENT TD-/315 SILENT
6 Performance curves Q = Air volume in, m 3 /hr and m 3 /s. Ps = Static pressure in mmwg and Pa. Dry air at º and 76 mmhg. Performance data in accordance with ISO 581, AMA 1-99 Standards and S 848 part :1985. = High speed = Low speed Ps Pe Pa mmwg mmcda Pabs (W) 6 TD-16/1 SILENT 5 4 Ps Pe Pa mmwg mmcda Pabs (W) 8 TD-5/1 SILENT E E 3 1 D A Q (m 3 /h) D A Q(m 3 /h) Q (m 3 /s) Q(m 3 /s) Ps Pe Pa mmwg mmcda Pabs (W) 8 TD-35/15 SILENT D A Q(m 3 /h) Ps Pe Pa mmwg mmcda Q(m 3 /s) E Pabs (W) 3 TD-8/ SILENT E Ps Pe Pa mmwg mmcda Ps Pe Pa mmwg mmcda 4 4 E Pabs (W) 18 TD-5/15-16 SILENT 15 1 D A Q(m 3 /h) Q(m 3 /s) E Pabs (W) 4 TD-1/ SILENT D A Q (m 3 /h) D A Q(m 3 /h) Q (m 3 /s) Q(m 3 /s)
7 Performance curves Q = Air volume in, m 3 /hr and m 3 /s. Ps = Static pressure in mmwg and Pa. Dry air at º and 76 mmhg. Performance data in accordance with ISO 581, AMA 1-99 Standards and S 848 part :1985. Ps mmwg Ps mmwg Acoustic characteristics Sound power spectrum: The sound levels shown in these tables are sound power levels at the discharge, radiated and inlet, in d(a) for frequency ranges at points of the curve: (A or D) free discharge, ( or E) medium pressure, ( or ) maximum pressure. () high speed, () low speed. Performance data in accordance with ISO TD-16/1 SILENT LwA LpA* A A RADIATED A Outlet TD-5/1 SILENT LwA LpA* A A RADIATED A OUTLET TD-35/15 SILENT LwA LpA* A A RADIATED A OUTLET TD-16/1 SILENT LwA LpA* D E D RADIATED E D OUTLET E TD-5/1 SILENT LwA LpA* D E D RADIATED E D OUTLET E TD-35/15 SILENT LwA LpA* D E D RADIATED E D OUTLET E * Sound pressure level radiated at 3 m. in free field condition, with rigid ducts at the inlet and outlet.
8 Acoustic characteristics Sound power spectrum: The sound levels shown in these tables are sound power levels at the discharge, radiated and inlet, in d(a) for frequency ranges at points of the curve: (A or D) free discharge, ( or E) medium pressure, ( or ) maximum pressure. VR, fast speed. VL, slow speed. Performance data in accordance with ISO TD-5/15 SILENT LwA LpA* A A RADIATED A OUTLET TD-5/15 SILENT LwA LpA* D E D RADIATED E D OUTLET E TD-8/ SILENT LwA LpA* A A RADIATED A OUTLET TD-8/ SILENT LwA LpA* D E D RADIATED E D OUTLET E TD-1/ SILENT LwA LpA* A A RADIATED A OUTLET TD-1/ SILENT LwA LpA* D E D RADIATED E D OUTLET E TD-13/5 SILENT LwA LpA* A A RADIATED A OUTLET TD-/315 SILENT LwA LpA* A A RADIATED A OUTLET TD-13/5 SILENT LwA LpA* D E D RADIATED E D OUTLET E TD-/315 SILENT LwA LpA* D E D RADIATED E D OUTLET E * Sound pressure level radiated at 3 m. in free field condition, with rigid ducts at the inlet and outlet.
9 Practical examples of installing TD SILENT range TD Silent range offers one of the most versatile fansystems on the market today. Due to its flexibility it can be used in a multitude of small or medium fan installations. Especially in places where working people and the ventilation system works for many hours, in these cases the sound level becomes an essential element for comfort.
10 Mounting accessories MA-S Non-return flaps to be installed at the fan discharge. They prevent heat leakages when the extractor is not operating. d a MA-S model range MA - 5 S 16/1N - 5/1 MA - 35 S 35/15 MA - 5/15 S 5/15 MA - 5/16 S 5/16 MA S 8/ - 1/ MA model range MA /5 MA - /315 MA-S model A Ø Ø D MA - 5 S ,5 94,5 MA - 35 S ,5 119,5 MA - 5/15 S , MA - 5/16 S , MA S 131, ,5 MA model A Ø Ø D MA , MA MAR-S Rectangular Duct Adapters enable connection to rectangular ducting. e a ø G MAR-S model range Nominal dimensions of the duct L x H MAR S 16/1N - 5/1-35/15 4 x 14 MAR - 5-S 5/15 8 x 18 MAR S 8/-1/ 315 x MAR-S model A E Ø G MAR S , MAR - 5-S MAR S MAR model range Nominal dimensions of the duct L x H MAR /5 4 x 5 MAR - /315 5 x 315 MAR model A E Ø G MAR MAR MRJ-S Grilles mounted at the inlet or outlet of the fan, to prevent the entry of any foreign objects that could damage the fan. MRJ-S model range MRJ S 16/1N - 5/1-35/15 MRJ - 5/15-16-S 5/15-5/16 MRJ S 8/ - 1/ MRJ model range MRJ /5 MRJ - /315
11 Mounting accessories MP-S low detectors designed to correctly measure pressures at the inlet of series TD devices with airflow straightner. MP-S model range MP-5 S 5/1 MP-35 S 35/15 MP-5/15 S 5/15-5/16 MP-5/16 S 5/16 MP-8-1 S 8/ - 1/ MP model range MP-1 13/5 MP- /315 MP-S model A D E G H MP-5 S 18 18,7 94, ,5 36,5 15,5 MP-35 S MP-5/15 S MP-5/16 S MP-8-1 S MP model A D E G H MP MP MR-S langes allowing the coupling of TD-Silent fans in series. MR-S model Ø of the conduct MR-5-35 S 15 MR-5 S 15 MR-8-1 S MR model Ø of the conduct MR-1 5 MR- 315
12 Electrical accessories REGUL speed switch. RE Single phase electronic speed controller. ONTROL EOWATT A/4A ontrol element for demand controlled ventilation systems in public, commercial residential buildings that automatically modifies the fan speed to adapt it to the needs defined in the system, measured with sensors. VAPZ Electronic single phase regulator that controls the fan speed with a simple contact (presence detector) or an analogical input, -1 V or 4- ma ( probe for relative humidity % RH). SO-A Ambient and temperature sensor. SO-AD Ambient and temperature sensor, with display. SHT-AD Ambient,temperature and relative humidity with display. PL-S / PL-E Presence detector for wall fitting, sensitive to infrared radiation by bodies in movement, with a 36º detecting angle. Power supply:1-3 V. TDP-S / TDP-D Presure sensor. Enables you to control the pressure in the fan inlet. Presure range: -5 Pa. Output signal: -1V/4- ma. REMP Motorised damper, opening proportionally and controlled by the EAS control module. Power supply: 4 VA or 4 VD, depending on the models.
8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!
Bathroom and toilet extract fans SILENT-100 BATHROOM EXTRACT FANS SILENT-100 Series SILVER versions The SILENT-100 CZ and CRZ can be supplied Range of axial extractors with airflow rates of approx. 95
More informationCADB and CADT-D / DI / DC Series
HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised
More information8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series
SILENT-1 Series Range of axial extractors with airflow rates of 85 m 3 /h, for connection to 1 mm diameter circular ducting. Motor mounted on silent-elastic-blocks which absorb the vibrations and allow
More informationSWIMMING POOL AIR-HANDLING UNITS KU-DB Series
SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =
More informationAir conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move
Air conditioning unit 2. Product information for the new Truma air conditioning unit October 2006 Edition Comfort on the move Air conditioning systems Manoeuvring systems Energy systems Heating systems
More informationAir Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg 83 84 85 85 86 88 89 90
6 Air Movement Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners Pg 83 84 85 85 86 88 89 90 83 Air Movement JKI Heaters Aurora Bathroom Heater Quartz 2
More informationTFSR & TFSK Roof Fans
Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans TFSR & TFSK Roof Fans With swing-out function 2 I TFSR/TFSK TFSR & TFSK Roof
More informationhore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
More informationHeating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
More informationFilter Fan Unit SILENT. Type SILENT AC Type SILENT EC
Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean
More informationPhotovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
More informationCE6500 Energy Recovery Ventilator
ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge
More informationUDSA - UDSBD unit heater
APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the
More informationSurface Technology. Centrifugal Fan GMD
Centrifugal Fan ATEX classed adapted for paint shops Wide assortment broad area of application Service friendly low maintenance costs Headquarters: Centrifugal Fan Centrifugal Fan is a direct driven industrial
More informationMaterial test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
More informationAirline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts
Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES
More informationsqurboxbox heat recovery squrboxbox I technical information
heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution
More informationVentilation Solutions Kitchens. fantech
Ventilation Solutions Kitchens 2 Kitchens Today s kitchens have become much more than a place for cooking and food preparation. The kitchen is the heart of the home. It s the center of activity for the
More informationFilterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000
Filterfans Patented Click & Fit design provides a hardware free installation! Poured-in foam gasket allows for quick NEMA 12 sealing against the enclosure (except PF 1000) Plastic made from strong (ABS-FR),
More informationSeries description: Wilo-Drain TC 40
Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site
More informationDéfumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.
Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally
More informationDuplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard
Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard Duplexvent DV72 EC MVHR is designed to provide constant volume ventilation levels to exceed the latest Building Regulations 2010. The
More informationHeating oven with mechanical control
ED series 53 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C (572 F). Thanks
More informationRKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features
RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,
More informationChilled Water Fan Coil Unit. Model:HFCA Size 03~14
Chilled Water Fan Coil Unit Model:HFCA Size 03~4 The Best Choice for Comfort =The Best Results Quiet Comfort Slope coil avoid air flow perpendicular impact Low noise permanent split capacitor motor Metal
More informationFlexit air handling unit K2 R
Flexit air handling unit K2 R with integrated kitchen hood PATENTED The quietest on the market Modern design Energy-efficient Installation in the kitchen A FOR A HEALTHY ENVIRONMENT Requirement-controlled
More informationTransformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
More informationO-I DUBI PLANT FANS Quotation Spec Data & Specifications
TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement
More information1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
More informationFULL DC INVERTER SYSTEMS
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation
More informationElectric Rotary Actuator - On/Off or programmable control actuator
Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type
More informationLow Cost. Lower Energy Costs. Higher Efficiency.
HI-E DRY dehumidifiers remove two to three times more water per kilowatt hour of electricity than conventional dehumidifiers. Low Cost. Lower Energy Costs. Higher Efficiency. Therma-Stor designed an efficient,
More informationWTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings
SWANTM WTW Linear slot air diffusers of wall-to-wall design for ceilings Quick facts Wall-to-wall installation Diffuser face of light aluminium design 2, 3 or slots Horizontal/vertical air distribution
More informationElegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner
Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of
More informationCommercial Air is the smart choice for top air conditioning performance and the best value for money system around.
Commercial Air is the smart choice for top air conditioning performance and the best value for money system around. Evaporative Air Conditioning The Commercial Air range of units are available in down,
More informationIncubator with mechanical convection
BF series 400 Incubators and cooling incubators Incubator with mechanical convection The BINDER incubator of the BF series with mechanical convection is suitable for all gentle incubation applications,
More informationRFHD. ROOF CENTRIFUGAL FANS WITH ATEX CERTIFICATION CEE ExII2G Ex d. According EU Regulation
RFHD ROOF CENTRIFUGAL FANS WITH ATEX CERTIFICATION CEE ExII2G Ex d According EU Regulation free RFHD Centrifugal roof fans with horizontal outlet and ATEX Ex d certification Centrifugal roof fans with
More informationInstallation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
More informationDiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered
Electrical Temperature Measurement DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered WIKA Data Sheet TE 60.75 Applications Machinery, plant and tank construction
More informationEC medium pressure axial fans. The effi cient system solution.
EC medium pressure axial fans. The effi cient system solution. GreenTech EC technology in a new dimension. Thanks to the new axial fans, our highly effi cient GreenTech EC technology is now available for
More informationSTERILIZERS, LABORATORY DRYING OVENS
TS9026 TS9053 TS9135 TS9430 TS 9000 SERIES: STERILIZERS, LABORATORY DRYING OVENS Series TS9000 consists of four different cabinets available in sizes from 26 litres to 430 litres. Interior housing and
More informationEnergy Saving ECM Motors and Fans. 2010 Ventilation Catalogue
Energy Saving ECM s and Fans 2010 Ventilation Catalogue CONTENTS For ellington, sustainability is about delivering products at competitive prices while preserving the environment for future generations.
More informationRadiant Temperature Sensor TY7321
AB-5361-U Specifications/Instructions Radiant Temperature TY7321 General TY7321 Radiant Temperature s are designed to measure infrared radiation from perimeter windows and walls and provide a proportional
More informationTechnical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
More informationHERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
More informationLUCCI AIRFUSION QUEST II CEILING FAN
LUCCI AIRFUSION QUEST II CEILING FAN WITH IR REMOTE INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE INSTALLATION AND FAN OPERATION. V1.0 QUEST II IR
More informationFundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer
Fundamentals of Acoustics & Practical HVAC Design Considerations Demir Doken Acoustic Engineer What is sound? Sound is a mechanical wave that is an oscillation of pressure transmitted through some medium
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationPHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:
PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV
More informationVacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
More informationUnder sill units. Type FSL-B-ZAS
.1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract
More informationWe have been working in an ideal climate for thirty years.
Underfloor cooling We have been working in an ideal climate for thirty years. A climate that has brought us to a position of leadership in Italy in the field of radiant heating and cooling. RDZ was the
More informationEurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
More informationkey- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100
Pointek CLS 100 Compact design and short insertion length. Ideal for constricted spaces and for small vessels or pipes up to 100 mm (4 ). Tecum cuil Ludere ipsae. Possem Precision level detection When
More informationClimasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
More informationPAGE 2. Figure 1: Difference between PWL ins and SPL 1m
PAGE 1 Pipe noise J.H. Granneman and R.P.M. Jansen, Peutz Consulting Engineers, The Netherlands, emphasise the need for an adequate pipe noise control procedure, with reference to the design phase, insulation
More information650W Single Output Power Supply
AK-650 series Features : Universal AC input with active PFC Programmable output Voltage ( 0% ~ 05% ) Programmable output Current ( % ~ 05% ) High efficiency up to 9% + / 0.5A auxiliary output Intelligent
More informationOperataing Manual. Single stage radial Fan. Model MKV/TKV
01.2011 Operataing Manual Single stage radial Fan Model MKV/TKV REITZ-SCHWEIZ VENTILATOR AG Zentweg 11 CH-3006 Bern Telefon +41 (0) 31 / 938 85-85 Telefax +41 (0) 31 / 938 85-86 Internet: www.reitz-schweiz.ch
More informationAccessory Manual Ventilation Section Model Comfort Circle
Accessory Manual Ventilation Section Model Comfort Circle Manual version:. R a Copyright and trademarks All the information and drawings in this manual are the property of Biddle and may not be used (other
More informationOnce you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.
COOLING FAN REQUIREMENTS CALCULATIONS Determining System Impedance Determining the actual airflow produced by a fan mounted in an enclosure is much more difficult than calculating the airflow required.
More informationTriple M1 The new MiniVent family. The professionals choice
Triple M1 The new MiniVent family The professionals choice Triple M1 The new MiniVent family NEW Triple M1 the MiniVent family is now complete. The most successful small room fan series from Helios now
More informationTechnical data UNIBLOCK UBSF 180 625
Data TECHNICL DT Technical data UNIBLOCK UBSF 80 6 Output data Type UBSF 80 UBSF 0 UBSF 00 UBSF 6 Output power 80 kv 0 kv 00 kv 6 kv Output voltage 80/77 V 0/ V 0/ V 0/ V Output current 7 8 66 80 Power
More informationDIMENSIONS SELV MODELS
25 CURZON - 1mm CENTRIFUGL FNS DIMENSIONS B Ø C D E Measured in mm : 216 B : 195 C : 5 D : 52 E : 98 Ø* * : 8/1 * (8mm without adaptor 1mm with adaptor) CURZON - 1mm CENTRIFUGL FNS 14 12 1 8 6 4 2 14 12
More informationNEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!
Flexit SL4 R Air Handling Unit with rotating recovery system Energy-efficient New control system NEW! Patent applied for! - Simple settings - Flexible installation - User friendly F O R H E A LT H Y I
More informationSi10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
More informationSmoke exhaust systems
1 Fire zone, e.g. hall 2 Smoke exhaust zone, separated by smoke curtains Natural and mechanical smoke extraction General information 3 Natural smoke and heat exhaust vent 4 Air inlet opening or wake max.
More informationUR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)
UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery
More informationHow To Use A Flowmeter
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationCooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
More informationThe compact unit series
The compact unit series The easy way to maintain a good climate i High, efficient energy recovery with an efficiency of 80 90 % i Energy-saving fan motors utilising EC technology for minimal energy consumption
More informationSwirl diffuser VSKA. Product facts. Quick selection. Swirl diffuser VSKA. Connection box ATTB. Product code example:
VSKA are supply air diffusers designed for ceiling mounting. The design of the air deflectors and discharge outlets causes the air discharged by the diffuser to mix with the air in the premises (high induction
More informationInstallation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
More information650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power
Features: Universal AC input / Full range Programmable output Voltage (0% ~ 05%) Programmable output Current (% ~ 05%) + / 0.5A auxiliary output Forced current sharing at parallel operation Power OK signal
More informationStroom voor elke toepassing
ELECTRICITY: ALWAYS & EVERYWHERE With VICTRON Phoenix MultiPlus and a HONDA Generator An intelligent combination with endless possibilities! Electrical appliances that increase on board comfort, such as
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationElectronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
More informationPD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description
Photoelectrics, Background Suppression reflective with IR light Main features Description The PD30ET... stainless steel sensors are built with high-quality materials and designed for harsh environments.
More informationLiebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
More informationT 3 Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T 3 SQ
TSQ--0 7-7-07 T Series VAV Diffusers Analog Diffuser Steel Square Panel Horizontal Pattern Model: T SQ Model Configuration T SQ- Heating / Cooling Border Type (Lay-In) Full Face Nominal Round Duct Size
More informationApplication. Design. Structure. Acoustics
Application The SMART fans are designed for general ventilation of buildings. They are meant for forwarding dry air of maximum temperature + C, and dustiness not exceeding,3 g/m3, without viscous, aggressive
More informationwww.inspection-for-industry.com
Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.
More informationyork air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
More informationKnow-how makes the difference. Electrical Actuators
Know-how makes the difference Electrical Actuators With Dansk Ventil Center as your business partner, you are always guaranteed a wide and well sorted product range and a unique technical know-how Product
More informationLED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature
LED LEONARDO 120 W LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature OVERVIEW The LED LEONARDO 120W is a highly efficient Fresnel lens spotlight using
More informationConlift1, Conlift2, Conlift2 ph+
GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications
More informationNew XUY roller sensors
Do you want to simplify the sensor integration in your conveyor systems? New XUY roller sensors for packet, boxes, letters on roller conveyors. Telemecanique Sensor s OsiSense TM XUY photoelectric sensors
More informationSecurity. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000
Security Alarm Central Unit 3 4 Technical KNX Alarm central unit EAM 4000 ETS-product family: Alarm system Product type: Alarm central unit The alarm central unit is a modern alarm system using the KNX
More information32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw
,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted
More informationMODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand
9041381- Issue 6 4/11 MODEL: DV72 Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation: Configuration
More informationOperation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415
Operation Instructions KleeBlower Compressor/Vacuum pumps Models: KB129 KB8415 Brd. Klee A/S All rights reserved Edition 01/2012 Head office: Branch office: Brd. Klee A/S Klee Engineering Ltd Gadagervej
More informationRM4TG20 three-phase network control relay RM4-T - range 200..500 V
Characteristics three-phase network control relay RM4-T - range 200..500 V Complementary [Us] rated supply voltage Output contacts Setting accuracy of time delay Delay at power up Measuring cycle Marking
More informationIndustrial infrared heater IR For premises with large volumes and high ceilings
3 3000 6000 W Electrical heat 3 models Industrial infrared heater For premises with large volumes and high ceilings Application is suitabe for total or supplementary heating of premises with large volume
More informationNews! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment
News! Flexit S20 R Air Handling Unit A new generation of Air Handling Units For a healthy indoor envionment Flexit S20 R Air Handling Unit Flexit is launching a new range of air handling units with capacity
More informationElectronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
More informationDSRQ - DSRSQ - DSRSQ-THERM
DSRQ - DSRSQ - DSRSQ-THERM Specification item: Variable geometry diffuser on 597x597 mm panel developed for rooms with high ceilings where a long throw and a high induction ratio are required. Made up
More informationFrequency Converter Fv
2 Bosch Rexroth AG Electric Drives and Controls Documentation Brake chopper with up to 30 kw continuous braking power Easy to operate and service (detachable fan, LCD operating panel with copy function)
More informationCRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ
GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html
More informationCLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability
PFD-P250VM-E PUHY-P250YJM-A(-BS) PUHY-P500YSJM-A(-BS) PQHY-P250YHM-A CLOSE CONTROL SYSTEM MITSUBISHI ELECTRIC s Close Control System (PFD series) is specifically designed for computer rooms, laboratories
More informationPPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES
PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES BUSHING WITH PLUG CONNECTION WITH OUTER CONE PPS CHARACTERISTICS The PPS bushing can be used as a fixed section for the entry of medium
More informationREGULINE 600VA / 1000VA REGULATOR USER MANUAL
REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate
More information