1 Data Center Cooling The engineer s choice
2 About ebm-papst Inc. Headquarters - Farmington, CT» 250K sq. ft.» Acoustic testing chamber» Complete air testing lab on site» Mechanical/Design Engineering» Electrical Engineering» Sheet Metal & Contract Manufacturing» ISO 9001 and Certification» Distribution centers in Farmington (CT) and Toronto, Canada Expert design and manufacturing Our staff of design, electrical, and application engineers possesses a wealth of knowledge and experience enabling unparalleled guidance and support to our customers and their projects. Cutting-edge equipment and innovative technologies are used to develop customer concepts into sub-assemblies or complete product ranges. Our engineers draw upon the vast resources available throughout the ebm-papst family to ensure that the most innovative and energy-efficient air movement components are correctly applied. Beginning with the initial product concept, our application engineers work in tandem with customers to select the best air moving solution to suit specific goals and requirements. Once the prototype has been established, it can then be tested in our state-of-the-art airflow testing chambers, allowing for the optimization of all air moving solutions. Each chamber has been designed to meet AMCA and ISO5801 requirements. In addition to our airflow testing capabilities, ebm-papst can conduct sound (in a semianechoic chamber), temperature and velocity tests. Design and electrical engineers advance the concept into a packaged air moving device incorporating sheet metal, fan controls, handlers, filters, gaskets and more. Our design engineers utilize the latest version of Pro-Engineer software to create a viable and cost-effective contract manufacturing solution. File sharing between customers and our team of engineers enables all stages of the prototype design to be verified before the initial build of the product. The electrical engineering team can design simple fan controllers for monitoring fan speed, or complex controllers and power supplies, filtering, and specific communication protocols. With these in-house tools, we can quickly take customer concepts to production.
3 About ebm-papst Worldwide World Headquarters: Mulfingen, Germany» Worldwide Revenue / Sales: 1.8 Billion USD» 57 Sales and Distribution Groups Worldwide» 17 Production Sites Worldwide» 9,900 Employees Worldwide» Ship Over 46 Million Products Annually» All Locations are ISO 9001 Certified» RoHS and ErP Directive Compliant GreenTech EC technology: Our motor for the future Virtually our entire product range is now available with GreenTech, the leading edge EC technology. GreenTech EC motors deliver unparalleled energy efficiency when compared to conventional AC Technology. With wear-free and maintenance-free performance, longer service life, reduction in noise, intelligent electronic control, and higher aerodynamic efficiency, GreenTech EC motors from ebm-papst are the future of air moving technology. Passionate about air technology and drive engineering The ebm-papst product portfolio now numbers over 14,500 products. Thus we offer the right solution for almost every air technology and drive engineering task. In addition, we work with you to develop very customized solutions that extend beyond our current product line. This is made possible by our extensive team of over 500 dedicated engineers and technicians out of our three central locations in Germany. Core competencies: motor technology, aerodynamics and electronics Our innovative technologies keep turning into new industrial standards. Our advantage: We consider aerodynamic relationships as a whole. Thus we combine benchmark-setting motor technology with the intelligence of stateof-the art electronics and aerodynamically optimized shapes. The system solution that results from these three core competencies have a synergy that is unique in all the world and make up the majority of our product line. Passion, quality and responsibility: Three reasons for our success Only real passion for fans and motors makes the highest level of achievement possible. With a clear organizational structure, flat hierarchies and a high degree of personal responsibility, we create the perfect foundation - not only technological innovation, but also for excellent service and active dedication to closely working with our customers. Our quality management is uncompromising, everywhere and in every process stage. This is also confirmed by our certification of compliance with the international standards DIN EN ISO 9001, ISO/TS and the standard DIN EN ISO
4 GreenTech The symbol of our commitment GreenTech is a name put to the philosophy ebm-papst has used for decades: each new product that we develop has to be better than its predecessor in terms of economy and ecology. Our company philosophy is not just for designing new and more efficient fans and blowers; it is in practice in the offices and factories, locally and internationally. At the U.S. headquarters, two separate arrays of solar panels have been installed to provide the engineering building with electricity, along with additional renovations that make the facilities even more environmentally friendly. GreenTech symbolizes our continuous commitment, achievements, and passion to provide customers with high quality products through the use of modern development and production methods, responsible business practices and initiatives that benefit not only the user, but the environment as well. What is EC Technology? EC technology is an important factor in our GreenTech philosophy. At the heart of this philosophy is the ebm-papst EC motor - a custom, high-voltage DC motor that permits higher efficiency and performance than traditional AC products. ebm-papst EC fans use permanent magnet external rotor DC motors with fully integrated electronic commutation (EC) and AC to DC power conversion. EC motors give the flexibility of connecting to AC mains with the efficiency and simple speed control of a DC motor. With EC fans, the user benefits from the innovative commutation without wear-and-tear on the motor. With this technology, EC motors and fans can be easily controlled, are maintenance-free, offer outstanding efficiency and have a considerably long service life. The variable speed range possible in EC technology makes using a multitude of individual models a thing of the past by offering control down to lower speeds compared to the full nominal speed. With EC technology, the same performance can be acheived from various voltage and frequency ranges. Our R&D efforts are not only focused on saving energy. In terms of air performance and low noise, our products exceed the toughest specifications. EC technology pays off for every owner or operator, while conserving precious energy resources. When you use intelligent ebm-papst EC technology in your applications, everyone wins - companies, customers, and the environment.
5 Table of Contents Data center cooling Fans and Their Function IT Product Overview Rack and Cabinet Level Cooling Modular Data Center Cooling Data Center Facility Cooling EC Plenum/K-modules EC Radial BCMI EC Axial Fans DC Impellers DC Compact Fans Accessories
6 Fans and Their Function Available in AC, DC or GreenTech EC design Fans from ebm-papst, which have long been the standard in electronics cooling, are available in these 3 designs: axial, centrifugal or diagonal. For each type, ebm-papst offers a large selection of fans, available in AC, DC or GreenTech EC design, for all voltages and in all standard sizes. With electronics built-in at the factory, they also offer numerous additional options and can be networked intelligently with MODBUS or other device logic. Radial impellers Medium flow rate at medium pressure If the required cooling air has to be turned 90 or if the system resistance is too high for an axial fan, radial fans are the most effective. ebm-papst offers not only motor/blower assemblies but also radial fan packages that include the inlet ring, power connector and housing for simpler installation. Plenum fans/radipac Medium flow rate at medium pressure The plenum fan is the easiest to integrate a radial impeller into a system. Plenum fans are driven by energy-saving EC external rotor motors with drive capacities between 400 W and 6 kw. The position of the impellers on the EC external-rotor motors have optimized aerodynamics and installation requirements. 6
7 For a full range of products and specifications, visit Axial fans High flow rate at lower pressure Axial fans supply air flow at relatively low system pressures, without changing the air direction. Mounting the impeller to the rotor eliminates the need for an external driveshaft, forming a very compact assembly. The motor and impeller assembly can be mounted to a wall plate with integrated venturi and a grill guard. This complete package provides easy mounting, low noise levels and high efficiency. Compact tubeaxial fans High flow at medium to high pressure Tubeaxial fans for the cooling of electronic equipment are equipped with external housing and an electric motor integrated into the fan hub. This compact construction allows space-saving accommodation of all devices and easy installation; the flange is equipped with mounting holes. ebm-papst compact fans are available in various IP (Ingress Protection) ratings, select models up to IP68. Diagonal fans High flow rate at relatively high pressure At first glance diagonal fans only differ slightly from axial fans. Intake is axial whereas exhaust is diagonal. Due to the conical shape of the wheel and housing the air is pressurized higher, in direct comparison with axial fans of the same size and comparable performance. These fans are also distinguished by the lower operating noise and higher efficiency. 7
8 IT Market Overview IT product cooling for data centers As new products and technologies emerge, the demands for more efficient data center systems increase. With each generation, IT equipment becomes smaller and more powerful, increasing the consumption of energy and consequently emitting more heat. Component overheating and heat build-up within enclosures are the primary causes for failure. If heat is not continuously removed it can result in reduced service life, severely impacting ROI and operating performance. ebm-papst understands the complexity of your company needs for continuous and reliable performance of electronic components in the data center environment. To meet the needs of company demands, ebm-papst offers thousands of off-the-shelf and custom solutions all incorporating innovative technology that enables the optimal performance needed to match the ever increasing demands of modern IT components. EC, the first choice for data centers Although fans and blowers can be used interchangeably with various applications, some are used more frequently than others. For data centers, radial impellers tend to be the first choice because of their natural high aerodynamic efficiency. Our radial impellers with EC technology are appropriate for evaporator fans for direct cooling, in-room-cooling systems, power exhaust, economizers, evaporative cooling, air to air heat exchangers, fan coil units, supplementary cooling systems, CRAC (Computer room air conditioning), CRAH (Computer Room Air Handling), unit cooling and air handling units. Axial fans can be chosen when applications limit the use of radial impellers. EC axial fans from ebm-papst are appropriate for condensers, chillers, evaporators, power exhaust systems and rooftop units. For the highest efficiency at variable load performance, multiple fans can be modulated together. The choice is simple - ebm-papst fans and blowers are the best solutions to deliver the results you need for your data center applications. 8
9 Rack and Cabinet Level Cooling Rack cooling for Data Centers Data center heat loads have increased dramatically as more components are squeezed into densely packed rack space. Excess heat in a server room adversely effects equipment performance, shortens equipment life-spans, and is the primary reason for downtime. Rack cooling ventilation designs should reduce hot spots and provide adequate cooling to every part at the rack level. Hot spots caused by improper airflow and poor circulation that are not properly cooled result in temperatures that exceed the recommended conditions for equipment reliability and performance. Effective cooling techniques must be employed so heat can be dissipated as efficiently and as close to the source as possible. This calls for the most innovative and efficient solutions to meet the challenging needs of data center applications. Maximum performance, custom solutions Our fans and blowers for rack cooling in data centers can direct cooled air to where it can be used most productively and efficiently and are available in a wide range of AC, traditional 12, 24, 48 VDC and full EC systems. Our compact fans are high performing, able to handle high backpressures, and can be intelligently controlled and adapted to specific requirements, all while delivering long service life and maintenance-free operation. Our wealth of contract manufacturing capabilities and expertise allows us to customize solutions to meet your unique data center needs. The preferred solutions for rack and cabinet level cooling: Radial impellers Diagonal fans Compact fans 9
10 Modular Data Center Cooling Modular / containerized data center cooling A new generation of data center is becoming an increasingly popular choice as the needs for more efficient systems grow. Some companies are migrating from large facility data centers to portable or modular data centers that are set up within sea containers or other pre-packaged systems. Portable or modular data centers are fitted to house many racks of IT equipment with ultraefficient cooling systems inside. These data centers can be manufactured and deployed more rapidly than traditional data centers because this style offers the easiest scalable solution while maintaining high operation efficiencies. Because the majority of portable and modular data centers don t have the same heat / cooling duct losses experienced in traditional data centers, the new configurations can super-charge their energy efficiency by incorporating ebm-papst s range of EC blowers and fans, from our small 80 mm fans up to 1250 mm models. The preferred solutions for modular / containerized cooling: Plenum fans/radipac Radial impellers HyBlade axial fans Compact fans 10
11 Data Center Facility Cooling Facility cooling Today s data center facilities require more power as demands for technology increase. Removing excess heat from a data center room or building requires a well-planned air moving design that directs cooling at various locations while maintaining overall area cooling. This dilemma can easily be solved by using sensors that constantly capture air and processor temperatures, used to automatically regulate fan speeds and cool system power, preventing systems from running continuously at full power. Our EC products can work as a fan with integrated controller (master) or with an existing facility controller (slave). The preferred solutions for facility cooling: Plenum fans/radipac Radial impellers HyBlade axial fans *For larger applications, axial and plenum fans are available in 1,250 mm. 11
12 EC Plenum Fans / RadiPac Features Sizes (mm): ø250 to ø1,250 Air Flow (CFM): 1,758 to 27,158 Frequency (Hz): 50/60 Voltage (VAC): 230, 277, 380, 480 Integrated electronics, extremely low noise and minimal heat generation with an aerodynamically optimized mounting package. Plenum fans Size Max. Air Flow Max. Static Power Input Nom. Speed Sound Max. Ambient Temp. Weight Series mm CFM (in. wg) Watts rpm db(a) C lbs. EG1R-XXX-250 ø250 1, , EG1R-XXX-280 ø280 2, ,000 3, EG1R-XXX-310 ø310 3, ,915 4, EG1R-XXX-355 ø355 3, ,700 2, EG1R-XXX-400 ø400 5, ,000 2, EG1R-XXX-450 ø450 7, ,370 2, EG1R-XXX-500 ø500 8, ,500 2, EG1R-XXX-560 ø560 10, ,700 1, RadiPac Size Max. Air Flow Max. Static Power Input Nom. Speed Sound Max. Ambient Temp. Weight Series mm CFM (in. wg) Watts rpm db(a) C lbs. K3G630 ø630 13, ,140 1, K3G710 ø710 15, ,000 1, K3G800 ø800 19, , K3G900 ø900 21, , *K3GZ50 ø1,250 27, , *Various designs in blade geometry and motor options for each nominal size listed enables higher / lower performances. Contact Engineering for specific part numbers and values 12
13 EC Radial Impellers Features Sizes (mm): ø333 to ø630 Air Flow (CFM): 133 to 13,741 Frequency (Hz): 50/60 Voltage (VAC): 230, 277, 380, 480 Integrated electronics, extremely low noise and minimal heat generation. Size Max. Air Flow Max Static Power Input Nom. Speed Sound Max. Ambient Temp. Weight Series mm CFM (in. wg) Watts rpm db(a) C lbs. R3G , R3G , R3G , R3G , R3G , , R3G , ,000 3, R3G , ,915 4, R3G , ,700 2, R3G , ,000 2, R3G , ,370 2, R3G , ,500 2, R3G , ,700 1, R3G , ,140 1, Not all sizes available in all voltages. *Various designs in blade geometry and motor options for each nominal size listed enables higher / lower performances. Contact Engineering for specific part numbers and values 13
14 EC HyBlade Axial Fans Features Sizes (mm): ø300 to ø1,250 Air Flow (CFM): 1,873 to 38,675 Frequency (Hz): 50/60 Voltage (VAC): 230, 277, 380, 480 Integrated electronics, extremely low noise and minimal heat generation. Size Max. Air Flow Max. Static Power Input Nom. Speed Sound Max. Ambient Temp. Weight Series mm CFM (in. wg) Watts rpm db(a) C lbs. W3G , , W3G , , W3G , , W3G , , W3G , , W3G , , W3G , ,200 1, W3G , ,830 1, W3G , ,980 1, W3G , ,880 1, W3G , , W3GZ50* 1,250 38, , *1,250 mm size only available with aluminum blade design. Contact Engineering for specific part numbers and values 14
15 DC Impellers Features Sizes (mm): ø101 to ø400 Air Flow (CFM): 112 to 1,947 Voltage (VDC): 12, 24, 48 DC fans with electronically commutated external rotor motor and fully integrated commutation electronics Size Max. Air Flow Max. Static Power Input Nom. Speed Sound Max. Ambient Temp. Weight Series mm CFM (in. wg) Watts rpm db(a) C lbs. RER RER120TD RER133TD RER160NTD RER175TD RER190TD RER220TD RER225TD R3G R3G R3G R3G Contact Engineering for specific part numbers and values 15
16 DC Compact Fans Features Sizes (mm): ø82 to ø200 Air Flow (CFM): 131 to 968 Voltage (VDC): 12, 24, 48 DC fans with electronically commutated external rotor motor and fully integrated commutation electronics. Compact Fans Size Max. Air Flow Max. Static Power Input Nom. Speed Sound Max. Ambient Temp. Weight Series mm CFM (in. wg) Watts rpm db(a) C lbs. 8200J 80x , J 92x , N 119x , x , x , Diagonal Fans Size Max. Air Flow Max. Static Power Input Nom. Speed Sound Max. Ambient Temp. Weight Series mm CFM (in. wg) Watts rpm db(a) C lbs. 2200F 200x , DV x , K3G x , Contact Engineering for specific part numbers and values 16
17 Accessories Temperature sensors Nominal Data Nom. Voltage Current Draw Output Voltage Output Current Output Impedance Measuring Temp. Part No. VDC ma VDC ma k C to to to 45 USB-RS485 adapter Part Number: The ebm-papst USB RS485 adapter connects RS485 devices to a computer USB. This also requires the ebm-papst EC Control software version 2.0 or later. The USB drivers required for operating the adapter are also included. Knob potentiometer Part Number: This unique design consists of a knob driving and incorporating a potentiometer. The mounting hardware and terminals are situated on the back side of the panel reducing to a minimum the required clearance. AxiTop axial fan diffuser Reduced noise at same air volume Less energy consumption at same air volume Increased air volume at comparable energy consumption [db(a)] [kw] [m 3 /h] % 25,000 The AxiTop diffuser is designed to recover wasted energy by purposely and efficiently decelerating the flow and reducing swirl, boosting the pressure rise of the impeller. Aerodynamic efficiency is increased and acoustic noise is reduced ,2 db(a) 80 27% Comparison figures measured in application, each with 800 mm EC fan. AxiTop is currently available for ebm-papst axial fan sizes 800mm and 910mm. 23,000 21,000 19,000 17,000 15,000 17
18 18
19 Notes 19
20 Printed in USA - 4/2013 ebm-papst Inc. Farmington 100 Hyde Road Farmington, CT Phone Fax [email protected] ebm-papst Inc ebm-papst Inc. reserves the right to change any specifications or data without notice The engineer s choice
ebm-papst North America
ebm-papst North America Data Center Cooling The engineer s choice About ebm-papst Inc. Headquarters - Farmington, CT» 250K sq. ft.» Acoustic testing chamber» Complete air testing lab on site» Mechanical/Design
ebm-papst North America
ebm-papst North America About ebm-papst North America About ebm-papst worldwide Headquarters - Farmington, CT 250,000 square feet 275 employees Contract manufacturing Acoustic testing chamber Complete
"AC2EC" - Replacement made easy New EC motor design Compact and efficient
"AC2EC" - Replacement made easy New EC motor design Compact and efficient The efficiency of the fans used is a central issue in ventilation and airconditioning technology. This is encouraged not only by
EC medium pressure axial fans. The effi cient system solution.
EC medium pressure axial fans. The effi cient system solution. GreenTech EC technology in a new dimension. Thanks to the new axial fans, our highly effi cient GreenTech EC technology is now available for
Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
- White Paper - Data Centre Cooling. Best Practice
- White Paper - Data Centre Cooling Best Practice Release 2, April 2008 Contents INTRODUCTION... 3 1. AIR FLOW LEAKAGE... 3 2. PERFORATED TILES: NUMBER AND OPENING FACTOR... 4 3. PERFORATED TILES: WITH
ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products
ECM Motors Manufactured By Regal Beloit Products and Applications- What s an ECM? ECM 2.3 series ECM 142 Arktic ECM 58mm Arktic ECM 59 Arktic SSC2 Arktic 51 GEXPRO Regal Beloit s distribution arm for all
Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC
Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean
zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s
TECHNICAL SPECIFICATIONS zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s 2015 LitePoint, A Teradyne Company. All rights reserved. The LitePoint zseries 18-slot chassis is an
Axial fans. version 07. The engineer s choice
Axial fans version 07 The engineer s choice Axial fans ebm-papst's axial fans prove their reputation as space-saving wonders by moving air for hot or cold air exchange in a wide variety of devices and
FAN SYSTEM REPLACEMENTS IN HVAC EQUIPMENT TO IMPROVE ENERGY
FAN SYSTEM REPLACEMENTS IN HVAC EQUIPMENT TO IMPROVE ENERGY Thomas Heine, Dipl.-Ing. (BA), BSc (Hons) Market Manager EC Upgrades, ebm-papst A&NZ 10 Oxford Road, Laverton North VIC 3026 [email protected]
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014
III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III.1. Large Roof Mount PN: 89-3037 Roof Mount Unit Eco 136 Parallel roof mount Air-conditioning and ventilation systems The Eco 136
Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000
Filterfans Patented Click & Fit design provides a hardware free installation! Poured-in foam gasket allows for quick NEMA 12 sealing against the enclosure (except PF 1000) Plastic made from strong (ABS-FR),
Power and Cooling for Ultra-High Density Racks and Blade Servers
Power and Cooling for Ultra-High Density Racks and Blade Servers White Paper #46 Introduction The Problem Average rack in a typical data center is under 2 kw Dense deployment of blade servers (10-20 kw
CADB and CADT-D / DI / DC Series
HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised
How to Build a Data Centre Cooling Budget. Ian Cathcart
How to Build a Data Centre Cooling Budget Ian Cathcart Chatsworth Products Topics We ll Cover Availability objectives Space and Load planning Equipment and design options Using CFD to evaluate options
Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.
COOLING FAN REQUIREMENTS CALCULATIONS Determining System Impedance Determining the actual airflow produced by a fan mounted in an enclosure is much more difficult than calculating the airflow required.
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
Heating, air-conditioning, cooling
Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft
Element D Services Heating, Ventilating, and Air Conditioning
PART 1 - GENERAL 1.01 OVERVIEW A. This section supplements Design Guideline Element D3041 on air handling distribution with specific criteria for projects involving design of a Data Center spaces B. Refer
Research RF Sputtering Packages
Research RF Sputtering Packages Shown with 3" Polaris Adjustable Position Source with Tilt and Shutter 300 or 600 Watt Low Cost Packages for Those With Limited Budgets Desiring Full Capability 13.56 MHz
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity
Liebert HPF The High Performance Floormount Indoor Package Cooling Solution Precision Cooling for Business-Critical Continuity We re Emerson Network Power, backed by Emerson, a global company that brings
Cooling Audit for Identifying Potential Cooling Problems in Data Centers
Cooling Audit for Identifying Potential Cooling Problems in Data Centers By Kevin Dunlap White Paper #40 Revision 2 Executive Summary The compaction of information technology equipment and simultaneous
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
Benefits of. Air Flow Management. Data Center
Benefits of Passive Air Flow Management in the Data Center Learning Objectives At the end of this program, participants will be able to: Readily identify if opportunities i where networking equipment
Chapter 3.5: Fans and Blowers
Part I: Objective type questions and answers Chapter 3.5: Fans and Blowers 1. The parameter used by ASME to define fans, blowers and compressors is a) Fan ration b) Specific ratio c) Blade ratio d) Twist
Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.
Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED. Presentation Goals & Outline Power Density Where we have been- where we are now - where we are going Limitations of Air Cooling
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet 1200 W Multi-Range DC Power Supplies Features & Benefits Any 9115 series model can replace several supplies on your bench or in your rack. Unlike conventional supplies with fixed output ratings,
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
NAISSUS THERMAL MANAGEMENT SOLUTIONS
NAISSUS THERMAL MANAGEMENT SOLUTIONS HIGH PERFORMANCE CLOSED LOOP WATER COOLING SYSTEM NTMS30 30kW SYSTEM Cool the servers, not the room! NAISSUS THERMAL MANAGEMENT SOLUTIONS HIGH PERFORMANCE CLOSED LOOP
FULL DC INVERTER SYSTEMS
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation
Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency
A White Paper from the Experts in Business-Critical Continuity TM Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency Executive Summary Energy efficiency
How To Save Energy On A Power Supply
Technical Note: Using EC Plug Fans to Improve Energy Efficiency of Chilled Water Cooling Systems in Large Data Centers A Technical Note from the Experts in Business-Critical Continuity Introduction A U.S.
Surface Technology. Centrifugal Fan GMD
Centrifugal Fan ATEX classed adapted for paint shops Wide assortment broad area of application Service friendly low maintenance costs Headquarters: Centrifugal Fan Centrifugal Fan is a direct driven industrial
SPECTRACOOL AIR CONDITIONERS PENTAIR EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING
SPECTRACOOL AIR CONDITIONERS PENTAIR EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING HOFFMAN SPECTRACOOL INDOOR/OUTDOOR AIR CONDITIONERS ENERGY-EFFICIENT, FILTERLESS AIR CONDITIONERS NOW AVAILABLE WITH
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
HVAC Infrastructure Retrofit Solutions
Kyoto Cooling Lunch & Learn David Belleville, APA LLC March 9, 2015 Owners choose APA solutions to: Rely on our 30+ years of delivering engineered solutions; HVAC Infrastructure Retrofit Solutions Insure
Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity
Liebert Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment Precision Cooling For Business-Critical Continuity The Intelligent Data Center Cooling Solution: Liebert Trust the industry
Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw
4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and
ABB central inverters PVS800 100 to 1000 kw
Solar inverters ABB central inverters PVS800 100 to 1000 kw ABB central inverters raise reliability, efficiency and ease of installation to new levels. The inverters are aimed at system integrators and
Transformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
Testing Capabilities. Worldwide Designers & Manufacturers of Air Moving Equipment
Testing Capabilities Twin Twin City City Fan Fan Companies, Companies, Ltd. Ltd. Worldwide Designers & Manufacturers of Air Moving Equipment TestingCapabilities Twin City Fan Companies, Ltd. In today s
Doc Ref: 2015.06.01.002. 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC
TM 602.783.1112 baselayer.com 2015 BASELAYER TECHNOLOGY, LLC TM D400E Data Module (60Hz) The EDGE D400E is designed to meet high power density requirements for both the HPC and Web Scale environments while
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
UDSA - UDSBD unit heater
APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the
Commercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
Multi-Range Programmable DC Power Supplies 9115 Series
Data Sheet Multi-Range Programmable DC Power Supplies 1200 W / 3000 W Multi-Range DC Power Supplies Features & Benefits Any model can replace several supplies on your bench or in your rack. Unlike conventional
EHDC. Cooling system for Data Center and server cabinets.
EHDC Cooling system for Data Center and server cabinets. EHDC PEN LP EHDC L is a High Density Cooling module for an pen Loop configuration. It is ideally installed with Enoc Systems cold corridor containment
EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE
EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE Vivek Khaire, Dr. Avijit Goswami Applied Thermal Technologies India 3rd Floor,C-Wing,Kapil Towers, Dr. Ambedkar Road, Pune- 411 1 Maharashtra,
Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure
Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing
Automotive BL-DC Fans for Commercial Vehicles. Edition 2015-10
utomotive BL-DC Fans for Commercial Vehicles Edition 5- utomotive BL-DC Fans for Commercial Vehicles Our automotive products BL-DC axial fans and BL-DC dual centrifugal fans with housing are ground breakers
Managing Cooling Capacity & Redundancy In Data Centers Today
Managing Cooling Capacity & Redundancy In Data Centers Today About AdaptivCOOL 15+ Years Thermal & Airflow Expertise Global Presence U.S., India, Japan, China Standards & Compliances: ISO 9001:2008 RoHS
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST
INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST MODEL CHCRV-5 For Use with Bard CH Series 3, 4 & 5 Ton 2-Stage Wall Mount Heat Pumps AND W38H, W43H, W49H and W61H Single Stage Wall Mount
How To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER The instructions that follow are to assist you in completing the information required when making a fan or blower selection. If you need additional
Photovoltaic Solar Energy Unit EESFB
Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality
NEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
Choosing Close-Coupled IT Cooling Solutions
W H I T E P A P E R Choosing Close-Coupled IT Cooling Solutions Smart Strategies for Small to Mid-Size Data Centers Executive Summary As high-density IT equipment becomes the new normal, the amount of
Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360
Autodesk Revit 2013 Autodesk BIM 360 Air, Fluid Flow, and Thermal Simulation of Data Centers with Autodesk Revit 2013 and Autodesk BIM 360 Data centers consume approximately 200 terawatt hours of energy
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in
GCS16 GCS20 WARNING CAUTION
Service Literature Corp. 0110 L6 Revised 12 2004 GCS16/GCS20 SERIES UNITS GCS16 GCS20 2 to 5 Ton GCS16/20 series units in the 2 to 5 ton (7.0 to 17.0 kw) cooling size are packaged combination gas heat
Dealing with Thermal Issues in Data Center Universal Aisle Containment
Dealing with Thermal Issues in Data Center Universal Aisle Containment Daniele Tordin BICSI RCDD Technical System Engineer - Panduit Europe [email protected] AGENDA Business Drivers Challenges
Performance Rating of Room Fan- Coils
ANSI/AHRI Standard 440 with Addendum 1 (Formerly ARI Standard 440) 2008 Standard for Performance Rating of Room Fan- Coils ANSI/AHRI STANDARD 440-2008 WITH ADDENDUM 1, PERFORMANCE RATING OF ROOM FAN-COILS
COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C
COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing
Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009
Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009 Agenda Overview - Network Critical Physical Infrastructure Cooling issues in the Server Room
MovinCool Office Pro Series. The Portable Spot Cooling Solution
MovinCool Office Pro Series The Portable Spot Cooling Solution The Office Pro 2002 American Standard Inc. All rights reserved Losing Is Not An Option With The Office Pro Series. The loss of data and equipment
Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors
European Refrigeration Controls Catalogue Catalogue Section 4 Product Bulletin P215PR/RM Issue 01/03/2013 Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for
Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity
Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise A White Paper from the Experts in Business-Critical Continuity Executive Summary Today s data centers are changing rapidly,
Datasheet Fujitsu PRIMERGY CX1000 S1 with 38 CX120 S1 The Cool-Central Architecture
Datasheet Fujitsu PRIMERGY CX1000 S1 with 38 CX120 S1 The Cool-Central Architecture New Cloud server infrastructure platform for Scale-Out data centers Scale Big - spend small PRIMERGY CX1000 is a new
SPECIAL ISSUE PART 2: TRUE VALUES DISCLOSURE
01 2015 Technology from ebm-papst SPECIAL ISSUE PART 2: TRUE VALUES DISCLOSURE Contents: 03 Editorial RadiPac = form + fit + function 04 General An ongoing development process: Plug & Play centrifugal
Silvertel. Ag5200. 1 Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power
Silvertel V1.1 November 2012 Datasheet Pb 1 Features IEEE802.3at and IEEE802.3af compliant Maximum 30W output power Dual In-Line (DIL) package size 50.6mm (L) x 30mm (W) Overload, short-circuit and thermal
Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre
Challenges In Intelligent Management Of Power And Cooling Towards Sustainable Data Centre S. Luong 1*, K. Liu 2, James Robey 3 1 Technologies for Sustainable Built Environments, University of Reading,
Oil / Air Cooling Units for mechanical engineering and mobile hydraulics
Oil / Air Cooling Units for mechanical engineering and mobile hydraulics ViFlow Finland Oy Kauppakartanontie 7 A 1 00930 Helsinki, Finland tel. +358 40 178 0920 fax +358 9 4789 2800 [email protected] www.viflow.fi
Benefits of Cold Aisle Containment During Cooling Failure
Benefits of Cold Aisle Containment During Cooling Failure Introduction Data centers are mission-critical facilities that require constant operation because they are at the core of the customer-business
RS-D and RSF-D series with direct drive
RENNER The expert in screw compressors RS-D and RSF-D series with direct drive Made in Germany rs All compresso h available wit ntrol! frequency co Motor size: 95 355 kw The company reliable and dynamic!
Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011
Fans and Air Handling Units Will Rea and Paul Pilutti February 16 th, 2011 HTS Lunch and Learns Available Online Visit www.htseng.com Engineering Tools Resource Center Contents Fans Fan Curves Fan Laws
News in Data Center Cooling
News in Data Center Cooling Wednesday, 8th May 2013, 16:00h Benjamin Petschke, Director Export - Products Stulz GmbH News in Data Center Cooling Almost any News in Data Center Cooling is about increase
1.44 kw Programmable DC Power Supplies XLN Series
Data sheet 1.44 kw Programmable DC Power Supplies XLN Series New Family of High Density System Power Supplies The B&K Precision XLN series are compact, programmable, single-output DC power supplies, suitable
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE.
EASYAIR flat THE COMPACT WAY TO A COMFORTABLE CLIMATE. LIFE IN PURSUIT OF QUALITY FROM THE VILLAGE FORGE TO A GLOBAL CORPORATION The Directors of AL-KO KOBER SE (from right to left): Stefan Kober (CEO),
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
Data Sheet Fujitsu PRIMERGY CX1000 S1 with 38 cloud server nodes
Data Sheet Fujitsu PRIMERGY CX1000 S1 with 38 cloud server nodes The Cool-Central architecture for Scale-Out Cloud Data Centers: Scale Big- Spend Small PRIMERGY CX1000 is a new product category within
Fan Basics and Selection Criteria (How to Use)
Feature: Understanding SANYO DENKI Products from Scratch Fan Basics and Selection Criteria (How to Use) Honami Osawa 1. Introduction In recent years, the importance of cooling technology has become even
Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V
SmartPro VS Tower UPS System Intelligent, line-interactive power management system Model #: SMART2200VS 2200VA / 2.2kVA line interactive tower UPS Maintains 120V nominal output over an input range of 79
Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts
Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES
High Power Programmable DC Power Supplies PVS Series
Data Sheet High Power Programmable DC Power Supplies The PVS10005, PVS60085, and PVS60085MR programmable DC power supplies offer clean output power up to 5.1 kw, excellent regulation, and fast transient
Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server
Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server High availability for lower expertise
squrboxbox heat recovery squrboxbox I technical information
heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution
FOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
EFFECTIVE OCTOBER 2005. Atwood Furnaces. and Digital Thermostats
EFFECTIVE OCTOBER 2005 Atwood Furnaces and Digital Thermostats Unique 2-Stage System Set the temperature, turn the thermostat on automatic and let the furnace take over! During cold start-ups, the furnace
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
DSA E-Series E2600, DE1600, DE6600. en Storage System Site Preparation Guide
DSA E-Series E2600, DE1600, DE6600 en Storage System Site Preparation Guide DSA E-Series Table of Contents en 3 Table of contents 1 About This Guide 5 2 Specifications of the E2600 Controller-Drive Tray
F9MXE. Product Specifications
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Select models earn the ENERGY STAR (See below, indicated with check mark.) Xtra SEER ECM blower motor Supports
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx
2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms
Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms Agenda Review of cooling challenge and strategies Solutions to deal with wiring closet cooling Opportunity and value Power
Problem / Solution. The problem:
Problem / Solution Solar Photovoltaic (PV) technology has shown significant development in recent years and this has led to many UK homeowners investing in Solar PV installations. Solar electricity is