UDSA - UDSBD unit heater
|
|
|
- Chloe Hubbard
- 10 years ago
- Views:
Transcription
1 APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater
2 V3 gas fired unit heater Reznor V3 unit heaters are one of the most technically advanced products available on the market today. Incorporating a radical new horizontal heat exchanger and burner, V3 units are compact and lightweight. They deliver the highest possible standards of energy efficiency and performance. The V3 range has 33 different models. The model with axial fan UDSA has firing rates from 8 to 100 kw in horizontal execution - 14 models - or vertical downflow - 10 models. The model with centrifugal fan UDSBD is available in 9 sizes from 15 up to 65 kw. V3 UDSA and UDSBD unit heaters are easy to install. They are suitable for indoors installation in industrial and commercial premises, retail, sports and leisure, warehouses and many other applications. TECHNICAL DATA UDSA Model Gas category BE II 2E+3+ / NL II 2L3P Comb.air and venting; type B & C-installations 1 B22, C12, C32, C42, C52, C62, C82 Heat input (Hs) kw 8,8 13,2 17,6 22,0 30,8 35,2 41,8 Heat input (Hi) kw 7,9 11,9 15,9 19,8 27,8 31,7 37,7 Heat output kw 7,3 11,0 14,6 18,2 25,5 29,2 34,7 Thermal efficiency (Hi) % Gas consumption rate natural gas G20 m 3 /h 0,84 1,26 1,68 2,10 2,94 3,36 3,99 natural gas G25 m 3 /h 0,98 1,46 1,95 2,44 3,42 3,90 4,68 propane G31 kg/h 0,62 0,93 1,24 1,55 2,16 2,47 2,94 Gas connection size (not Ø gas supply line) Rc 1/2 Temperature rise ΔT (±1) 6 K Airflow (15 C) m 3 /h Motor speed rpm Vent & combustion air connection collars Ømm recommended max. horizontal mounting height 2 m 2,5 2,5 3,0 3,0 3,5 3,5 3,5 Horizontal throw 3 m Sound pressure level 4 db(a) Sound pressure level 5 db(a) Electrical service class (protection class IP 20) 230/240V 1N ~ 50Hz Maximum total electrical rating W Weight (net) kg
3 Energy saving Easy installation and maintenance Up to 25% lighter than similar models and easy to install. Balanced flue wall terminal provides both flue outlet and combustion air inlet, thereby reducing installation time. All connections - gas and electricity - are accessible at one side of the heater. 4-pass heat exchanger, achieves over 92% thermal efficiency. Reduced NOx emissions. An improved airflow and a new louvre design give longer air throws and significantly reduce stratification within the building. Consequently, the units are particularely suitable for well insulated buildings. If necessary, destra- tification fans can be installed. Aerodynamic heat exchanger profile enables the UDSA to increase airflow up to 40% with a 30% reduction on electrical consumption. Maintenance is very simple thanks to the use of a single gas injector for all models Extended operational life The titanium stabilised aluminised steel heat exchanger is particulary strong and durable providing additional temperature resistance. Its weld free construction ensures long life. The patented self-aligning burner with single orifice eliminates possible flame impingment and premature heat exchanger failure. Application versability BE II 2E+3+ / NL II 2L3P B22, C12, C32, C42, C52, C62, C82 50,8 58,6 66,0 77,7 88,0 102,7 117,3 45,8 52,8 59,5 70,0 79,3 92,5 105,7 42,1 48,6 54,7 64,4 73,0 85,1 97, Both horizontal and vertical down flow units are available. Fourteen different heat outputs from 8 to 100 kw. The smallest unit is only 310 mm high, making it ideal for confined spaces. Units may be suspended or base mounted on a suitable non-combustible support. 4,85 5,59 6,30 7,41 8,39 9,79 11,18 5,64 6,50 7,32 8,62 9,76 11,38 13,00 3,57 4,12 4,64 5,46 6,18 7,21 8,24 Rc 3/ ,5 3,5 3,5 4,0 4,0 4,0 4, /240V 1N ~ 50Hz
4 V3 gas fired unit heater UDSA horizontal model with axial fan Model UDSA dimensions (mm ± 2) Model A B C D E F G H J K L M N P Q R 008, , 043, , , 085, Combustion air inlet 2. Flue connection 3. Gas connection 4. Electrical connections 5. Service panel D B F E M N Q P A C 5 FRONT VIEW SIDE VIEW TOP VIEW R L J G 4 K H REAR VIEW (models 035, 043, 050) REAR VIEW (all models except 035, 043, 050) BALANCED FLUE WALL AND ROOF TERMINAL Type C12 Type C12b Type C52 Type C32 Type B22 Type B22b C-type: the allowed length between the unit heater and the flue terminal amounts to 9m, a 90 bend offering an equivalent resistance of 1.5 m and a 45 bend m
5 UDSA vertical model with axial fan To ensure that heat loss through the roof is kept to a minimum and to avoid stratification, it is possible to suspend a vertical UDSA model. This unit can operate dually as a heater and as a destratification unit. The option vertical orientation (option number 205.8) can only be specified for UDSA 015, 025, 035, 043, 050, 055, 064, 073, 085 & 100. All vertical UDSA models are fitted with a four-way outlet grill (no louvres). The vertical UDSA can function as a destratification unit by placing a destratification thermostat (option 904). This combination will allow the vertical UDSA to ventilate and recirculate warm air towards the floor, which results in energy savings and climate comfort. H Floor pattern Diffuser grill louvre setting N M H MOUNTING DATA P N M P N M Maximum mounting height from floor H (m) 1 Model Air louvres neutral Air louvres 30 Air louvres 45 Q Q P 015 5,0 4,5 4, ,0 5,0 4, ,0 6,0 5, ,0 7,5 7, ,0 8,5 7, ,0 7,5 7, ,5 8,5 8, ,0 8,0 7, ,0 9,0 8, ,0 10,0 9,0 MODEL UDSA DIMENSIONS (mm ±2) Model E F M N P Q Q ,043, , ,085, max. mounting heights are defined at a uniform room temperature of 15 C and a temperature rise at nominal heat input for other dimensions: see table indicated as horizontal UDSA model
6 V3 gas fired unit heater UDSBD horizontal model with centrifugal fan Reznor s V3 model UDSBD is a gas fired unit heater with separated combustion and atmospheric burner. It is equipped with a direct drive centrifugal fan and can cope with external static pressures up to 150 Pa. The UDSBD also exists in a vertical execution for models 015, 025, 035, 043, 050, 055 and 064. The UDSBD is designed for air recirculation and air distribution through ductwork, a plenum, a standard outlet grill, vertical louvres and downturn nozzles. UDSBD units are ideal for heating open doorways with constant running fans or room temperature controlled space heating. TECHNICAL DATA UDSBD Model Gas category BE II 2E+3+ / NL II 2L3P Comb.air and venting; type B & C-installations 1 B22, C12, C32, C42, C52, C62, C82 Heat input (Hs) kw 17,6 22,0 30,8 35,2 41,8 50,8 58,6 Heat input (Hi) kw 15,9 19,8 27,8 31,7 37,7 45,8 52,8 Heat output kw 14,6 18,2 25,5 29,2 34,7 42,1 48,6 Thermal efficiency (Hi) % Gas consumption rate natural gas G20 m 3 /h 1,68 2,10 2,94 3,36 3,99 4,85 5,59 natural gas G25 m 3 /h 1,95 2,44 3,42 3,90 4,68 5,64 6,50 propane G31 kg/h 1,24 1,55 2,16 2,47 2,94 3,57 4,12 Gas connection size (not Ø gas supply line) Rc 1/2 Rc 3/4 Temperature rise ΔT (±1) 6 K Airflow (15 C) m 3 /h Motor speed rpm Standard low, mid or high speed mid high low mid low low mid recommended max. horizontal mounting height 2 m 3,5 4 4,5 4,5 5,5 5,5 6 Horizontal throw 3 m Sound pressure level 4 db(a) Sound pressure level 5 db(a) Electrical service (protection class IP 20) 230/240V 1N ~ 50Hz Maximum total electrical rating W Weight (net) kg
7 UDSBD horizontal model with centrifugal fan Model UDSBD dimensions (mm ± 2) Model A A1 B C D E F G H J K L M N P Q R 015, , ,043, Combustion air inlet 2. Flue connection 3. Gas connection 4. Electrical connections 5. Service panel D FRONT VIEW SIDE VIEW TOP VIEW REAR VIEW (models 015,020, , 055,064) REAR VIEW (models 035, 043, 050) ,0 77,7 59, ,7 64, ,30 7,41 7,32 8,62 4,64 5, mid high ) Gas appliance classifications for approved venting methods based on CEN report - CR1749: ) Height from floor to bottom surface of the heater. These are recommendations only. Positioning of unit heaters for proper performance depends on application. Operation is affected by other air moving equipment in the space, obstructions to the air flow, draughts and/or close proximity to doors or windows, etc. Care should be taken to avoid mounting the heaters above these recommendations, unless downturn nozzles options are used, as significant stratification may occur, resulting in poor floor coverage and higher energy through the roof structure. 3) Isothermal conditions - 20 C ambient air temperature, discharge louvres, zero deflection, v=0.5m/s 4) db(a) values 5 metres from the unit with reference circumstances A=160m 2 and Q=2 5) db(a) values at 5 metres from the unit in free field 6) Values measured with an external static pressure of 150 Pa
8 OPTIONS Unit heater accessories Two stage burner control Modulating burner control Propane model Destratification thermostat Stainless steel 409 heat exchanger Diffuser grill with horizontal louvres 30 or 60 discharge nozzle Vertical louvres Duct flange* Constant running fan Flue outlet Balanced flue wall and roof terminal Aluminised steel plate Adjustable chimney for pitched roof Mounting Fixed or pivoting wall brackets available Wall brackets for UDSA models or 60 discharge nozzle Control equipment Combined thermostat with burner operating state signalisation and reset 1 or 2 stage clock thermostat Energymizor 2, ideal for 1-stage, 2-stage and modulating REZNOR burners. The microprocessor adjusts the heating period and air temperature Room temperature sensor for space heating Duct thermostat for temperature control in a warm air inlet system* Two stage duct thermostat* Opentherm thermostat *UDSBD only J&M Sabbestraat 130/A000 B-8930 Menen Belgium Tel. +32(0) Fax. +32(0) [email protected] Wall brackets for UDSA models Pivoting wall bracket for UDSA models Company Standards and Services: All Reznor products are tested and approved to CE standards. Reznor Europe nv is assessed to ISO 9001 Quality Assurance. Reznor offers a service to its customers; including budget schemes. on site technical support and a comprehensive after-sales package. Reznor reserves the right to change specifications without prior notice. 1405_V3_UDSA_UDSBD_EN
RPV - RP - RA air handling units
APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
HEAVY DUTY STORAGE GAS
Multi-Fin flue technology Flue damper saves energy Electronic controls HEAVY DUTY STORAGE GAS Dependability The Rheem heavy duty gas range is the work horse of the industry having proved itself over many
Product Overview Benefits
Trade Data CP CP Upright / CP Horizontal / CP Counterflow / CP EA External Heaters and Fired Warm Air Heaters Heat Outputs from 26kW - 586kW Issue 1.02 Print 2 ay 2011 Product Overview Benefits Installer
Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
Aludesign K A T A L O G
Aludesign K A T A L O G plynové radiátory DESIGN The result of lengthy experience and technological research, GAZELLE TECHNO today is a universally recognised gas radiator*. It has been completely re-designed
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
Cabinet heater. Gas fired cabinet heater with atmospheric burner for indoors installation for free blowing applications or connection to ductwork
Cabinet heater Installation/Commissioning/Maintenance/User instructions Gas fired cabinet heater with atmospheric burner for indoors installation for free blowing applications or connection to ductwork
Johnson Air-Rotation Systems
AR Series TM Johnson Air-Rotation Systems Solution TM D Series TM FF Series TM 80/20 PR Series TM Johnson Air-Rotation systems announces a major addition to its product line, completing its line of high
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in cooling California NOx
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
96% AFUE, Two Stage ECM Gas Furnace EASIER TO SELL 96% AFUE, all models, all positions Two stage heating operation Xtra SEER ECM blower motor Supports two stage cooling units Dehumidification feature in
FULL DC INVERTER SYSTEMS
FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation
Industrial infrared heater IR For premises with large volumes and high ceilings
3 3000 6000 W Electrical heat 3 models Industrial infrared heater For premises with large volumes and high ceilings Application is suitabe for total or supplementary heating of premises with large volume
Commercial Gas Furnace Upflow
Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted
hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes
Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,
Gas water heaters. Why Vaillant? Because warm water is our business for more than 135 years.
Gas water heaters Why Vaillant? Because warm water is our business for more than 5 years. atmomag turbomag Innovative Ideas for warm water Vaillant Gas Water Heaters atmomag and turbomag Since the beginning
Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...
Solar air collectors for industry and larger halls N S Ø Efficient dehumidification and air heating for free... This booklet contains information about SolarVenti Industrial air solar system. The system
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS
DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS Electronic thermostatically controlled Low power consumption Compact space saving size Short heat-up times Dehumidification of the cabin Quiet when running Combustion
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard
Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard Introduction SRU s (Sulfur Recovery Units) are critical pieces of equipment in refineries and gas plants. SRUs remove sulfur compounds from certain
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES
COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES These guidelines are to be used for ALL commercial cooking hoods, ventilation systems and related fire suppression
Cooling Capacity CFM range @.5 in. w.c. (125 Pa)
N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air
1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
O-I DUBI PLANT FANS Quotation Spec Data & Specifications
TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement
- mark gas burners Cuenotherm NC.4 - NC.6 - NC.9 14.5-90kW.
- mark gas burners Cuenotherm NC.4 - NC.6 - NC.9 14.5-9kW. Low NO x Comprehensive control panel Gas rack Low NOx combustion head Strong light alloy pressuremoulded housing Electronic ignition transformer
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts
Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES
Glossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
F9MXE. Product Specifications
96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL 96% AFUE, all models all positions Select models earn the ENERGY STAR (See below, indicated with check mark.) Xtra SEER ECM blower motor Supports
CRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
SWIMMING POOL AIR-HANDLING UNITS KU-DB Series
SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =
SPECIALIST RENTAL PROVIDER HEATING & HOT WATER PACKAGES
SPECIALIST RENTAL PROVIDER HEATING & HOT WATER PACKAGES Electric, IDF, Gas & Oil Fired Technology Heating Capacity 2.0-2,000kW ICS Cool Energy Hire Division The hire division of ICS Cool Energy is your
TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES
TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S NATURAL GAS 40-130 MBH INPUT Due to continuous product improvement, specifications are subject to change
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE
UPF/HORIZONTAL 2-, VARIABLE SPEED GAS-FIRED FURNACE XV80 MODELS TUD2B060A9V3VB, TUD2B080A9V3VB TUD2C080A9V4VB, TUD2C080B9V4VB TUD2B00A9V3VB, TUD2C00A9V5VB TUD2C00B9V5VB, TUD2DA9V5VB TUD2DB9V5VB, TUD2DA9V5VB
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas
Methods for Effective Room Air Distribution Dan Int-Hout Chief Engineer, Krueger Richardson, Texas Agenda Overview LEED issues and Update Perimeter Acoustics Thermal Comfort IAQ / Standard 62.1 Update
Thermal destratification in buildings: The missing piece to the HVAC puzzle
WHITE PAPER Thermal destratification in buildings: The missing piece to the HVAC puzzle January 2013 Thermal Destratification In Buildings: The missing piece to the HVAC puzzle 1. What is Thermal Destratification
Saving Heating Costs In Warehouses
2005, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. (www.ashrae.org). Reprinted by permission from ASHRAE Journal, (Vol. 47, No. 12, December 2005). This article may not
G9MXE. Product Specifications
Up to 96% AFUE, Single Stage, ECM Gas Furnace EASIER TO SELL Up to 96% AFUE, all models all positions California NOx approved Select models earn the ENERGY STAR (See below, indicated with check mark.)
TFSR & TFSK Roof Fans
Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans TFSR & TFSK Roof Fans With swing-out function 2 I TFSR/TFSK TFSR & TFSK Roof
We have been working in an ideal climate for thirty years.
Underfloor cooling We have been working in an ideal climate for thirty years. A climate that has brought us to a position of leadership in Italy in the field of radiant heating and cooling. RDZ was the
2006 Delta T Corporation dba Big Ass Fan Company
Saving Energy Savings with HVLS Fans Josh Eddy LEED-AP National Sales Manager Big Ass Fans Outline Who is Big Ass Fans HVLS fan types How HVLS fans save energy HVLS fan applications How utilities are helping
ONE STAGE LIGHT OIL AND KEROSENE BURNERS
ONE STAGE LIGHT OIL AND KEROSENE BURNERS RDB SERIES RDB-R 6,8 4,6 kw RDB-R 4, 46, kw RDB.-.R, 4, kw RDB.-.R,, kw RDB,6 68,7 kw RDB. 4,, kw RDB4,7, kw The Riello RDB series of one stage light oil and kerosene
Operation and Installation Manual. Max Series
Operation and Installation Manual Max Series Models 95MAX 155MAX 155ECM 155MAXRX 200MAX 200MAXRX MAXTOP 195DCS 300DCS 200ERV 200ERVD New Auto Dehumidistat Function prevents unwanted use of the dehumidistat
M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace
TECHNICAL SPECIFICATIONS M7RL Series High Efficiency / Direct Vent Condensing Downflow Gas Furnace Induced Draft - 9%+ AFUE Input 4,000 thru 7,000 Btuh The high efficiency downflow gas furnace is especially
High efficiency, cast-iron gas boiler
SENTRY High efficiency, cast-iron gas boiler LOWER PROFILE MAKES PROBLEM INSTALLATIONS EASY SENTRY High efficiency, cast-iron gas boiler A smarter choice for informed The boiler you choose for your home
NAVIEN AMERICA INC. 17855 FITCH AVENUE
Navien America Inc. Specification Details for the Navien models: CC-240 CC-240A For Potable Water Heating and Space Heating NAVIEN AMERICA INC. 17855 FITCH AVENUE IRVINE, CALIFORNIA, USA 92614 Toll Free:
Ventilation Solutions Kitchens. fantech
Ventilation Solutions Kitchens 2 Kitchens Today s kitchens have become much more than a place for cooking and food preparation. The kitchen is the heart of the home. It s the center of activity for the
High-efficient gas boiler CompactGas
High-efficient gas boiler CompactGas Patented alufer for a high efficiency and low emission. 1 CompactGas (1000-2800). Advantages at a glance. The Hoval CompactGas fulfils all expectations with regard
HDA -----------------------------------------------------------
----------------------------------------------------------- Lightstrips ---------------------------------------------------------------------- Ceiling system for heating and cooling LIGHTSTRIPS LIGHTSTRIPS
Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC
Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide
EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation. 1.1.1 The Building Regulations 2010
EFA PSBP Natural Ventilation Strategy Introduction The Baseline Designs Project will provide scheme design details for a number of Primary and Secondary School Exemplars. For the purposes of setting a
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters
Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters FEATURES ULTRA-LOW NOx CONDENSING TECHNOLOGY PROVIDES UNPRECEDENTED 0.95 ENERGY FACTOR DURABLE HEAT EXCHANGER Primary Heat Exchanger
HIGH EFFICIENCY RTU. www.reznorhvac.com HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons
Capacities 10-25 Tons 100-400 MBH HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING DX System IEER> 13.2 Gas Heat Efficiency > 92% HIGH EFFICIENCY RTU 30-120 kw 3,000-11,550 CFM Comfort Comfort is determined
AIR-COOLED CHILLERS APPLIED SYSTEMS. www.daikin.eu EUWA*5-24KAZW - EUWY*5-24KAZW -
AIR-COOLED CHILLERS APPLIED SYSTEMS www.daikin.eu Cooling Only Heat pump EUWA*5-24KAZW - EUWY*5-24KAZW - Environmental Awareness Daikin and the Environment In recent years, motivated by a global awareness
UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual
UHIR Series Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater Owner s Manual This manual covers installation, maintenance and repair parts. Read carefully before attempting to
CADB and CADT-D / DI / DC Series
HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised
Decree of the Ministry of the Environment on fire safety of ventilation systems
THE NATIONAL BUILDING CODE OF FINLAND MINISTRY OF THE ENVIRONMENT Housing and Building Department Decree of the Ministry of the Environment on fire safety of ventilation systems Adopted in Helsinki, 18
How To Design A Gas Dryer
Non Domestic Laundry Gas Appliance Installation Code of Practice Introduction This code of practice has been produced with the assistance of all Companies within the OPL sector of SLEAT because of the
Using waste heat. with gas-fired steam humidifiers Condair GS. Humidification and evaporative cooling
Using waste heat with gas-fired steam humidifiers Condair GS Humidification and evaporative cooling Economical and ecological steam production with gas as primary energy. Gas-operated steam humidification
Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko
INSTALLATION MANUAL Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko Ventilated Notified entity Building Technical and Research Institute Prague notification no. 1020 This instruction refers to double-layer
Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55
Frequently Asked Questions Air Top Diesel Heaters 2000STC, Evo 40 & Evo 55 Question 1 What power outputs are the heaters available in? There are 3 models 2kW, 4kW and 5.5kW Question 2 What voltage are
FOREWORD LEGEND FUEL TYPE MMD Equipment
FOREWORD Since 1975, MMD Equipment has supplied the highest quality construction equipment to the North American market. Once solely a distributor, today MMD has grown into a comprehensive global manufacturer
Stove-boiler for solid fuels 12-30 KW Directions for use and assembling
Stove-boiler for solid fuels 12-30 KW Directions for use and assembling February 7, 2012 Contents 1 Technical data 2 1.1 Boiler properties TEMY PLUS 12-30 KW......................... 3 1.2 On Product............................................
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate
1 919 1919P01 1919P03 QBM65/C, QBM75-1U/C Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate QBM751-1/C QBM65/C QBM75/C Highly accurate measurements with calibration
Apartment and Communal Heating Solutions
Apartment and Communal Heating Solutions Apartment and Communal Heating Due to the increasing requirements for more energy efficient buildings and changes to the Code for Sustainable Homes Legislation,
Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial
Problem Statement In order to satisfy production and storage requirements, small and medium-scale industrial facilities commonly occupy spaces with ceilings ranging between twenty and thirty feet in height.
Air Conditioning Sign-Off Sheet
Air Conditioning Sign-Off Sheet Printed Technician Name Address Social Security Number Telephone Number City State Zip Code Install Or Verify The Accuracy Of An Air Conditioner s Installation The candidate
HIGH QUALITY COMPONENTS
Eco reen Line HIGH QUALITY COMPONENTS that distinguish Eco reen Line series of devices 1. The lambda probe it performs a function of an oxygen sensor (O ) in the exhaust gasses, providing constant diagnostic
Gas Boilers - Commercial
Gas Boilers - Commercial Gas Boilers - Commercial Commercial Wall Hung Gas Boilers C.2 Commercial Wall Hung Gas Boiler Flues C.2 Commercial Wall Hung Gas Boiler Accessories C.3 Commercial Wall Hung Gas
marine/bespoke split applications
split applications marine/bespoke evaporators, condensers and split air conditioning systems suitable for a multitude of applications such as coastal, extreme high and low ambients, harsh dusty environments
Commercial Gas Water Heater
Commercial Gas Water Heater 3-Year Limited Tank/1-Year Limited Parts Warranty* The Polaris has a high grade 444 stainless steel tank with brass connections for years of dependable, trouble-free service
TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans
IN-LINE MIXED LOW DUT ANS ultra-quiet Series (16 to 1 models) Low profile Mixed-flow fans with sound-absorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD-35, TD-5, TD-8
Air-water systems for efficient air conditioning
Air-water systems for efficient air conditioning The art of handling air System overview Passive cooling systems Induction units Façade ventilation units Page 4 Page 6 Page 10 Passive Chilled ceiling Undersill
2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms
Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms Agenda Review of cooling challenge and strategies Solutions to deal with wiring closet cooling Opportunity and value Power
(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark
Spectrum Laboratories Ltd is accredited by International Accreditation New Zealand (formerly Telarc). The tests reported herein have been performed in accordance with the terms of our accreditation. This
RHC 8000(M) DJL for indoor use RHC 8000(M) RJL for outdoor use
0905RHC8DJL/RJLGBEN Gas-Fired, Balanced-Flue or Power-Vented Unit Heater RHC 8000(M) DJL for indoor use RHC 8000(M) RJL for outdoor use INSTRUCTION DOCUMENT APPLIES FOR: Installation Commissioning Servicing
The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair
The Concept A Europe-wide research and development programme identified the need for a high performance cassette fan convector, powered by low pressure hot water and compatible with universal suspended
APC APPLICATION NOTE #112
#112 Best Practices for Deploying the InfraStruXure InRow SC By David Roden Abstract The InfraStruXure InRow SC (ACSC100 and ACSC101) is a self-contained air conditioner for server rooms and wiring closets.
squrboxbox heat recovery squrboxbox I technical information
heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design
SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels
DSRQ - DSRSQ - DSRSQ-THERM
DSRQ - DSRSQ - DSRSQ-THERM Specification item: Variable geometry diffuser on 597x597 mm panel developed for rooms with high ceilings where a long throw and a high induction ratio are required. Made up
PELLEXIA COMFORT ENVIRONMENT COMPATIBLE
PELLEXIA COMFORT ENVIRONMENT COMPATIBLE To valorize the pellet MODEL nominal output min/max kw global output min/max % pellet reservoir content kg PELLEXIA 7 8 7 8,8 89 50 PELLEXIA 40 3 39,7 85 90,3 50
Displacement ventilation
General The displacement ventilation principle is the oldest form of ventilation and can be achieved without the use of fans. Air movement occurs by means of the density differences between supply air
GTS Gas-to-Steam Humidification System
GTS Gas-to-Steam Humidification System Gas has lowest energy operating costs The industry s first and best-selling gas-to-steam (GTS ) humidifier continues to be your best choice for reducing energy costs
Gas-Fired, Balanced-Flue or Power-Vented Unit Heater. Installation, commissioning, servicing & user instructions
1505LCSA-3--EN Gas-Fired, Balanced-Flue or Power-Vented Unit Heater LCSA-3 12-3, 20-3, 30-3, 35-3, 45-3, 60-3, 75-3, 100-3, 120-3, 145-3 Installation, commissioning, servicing & user instructions These
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6
- B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &
RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features
RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,
The Best Selling Domestic Stainless Steel Oil Boiler
The Best Selling Domestic Stainless Steel Oil Boiler Stainless Steel Oil Boiler / Standard Oil Boiler Convenience By using the prograed timer, you can control the HEATING / OFF functions inside your room
Quinta Range. Condensing Boilers REMEHA QUINTA RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission
Quinta Range Condensing Boilers REMEHA QUINTA RANGE High efficiency wall hung condensing boiler with ultra low NOx emission QUINTA RANGE OUTPUTS Q30: 5.6-28 kw Q45: 7-40 kw Q65: 11-61 kw Q85: 14.4-84.2
Energy Efficiency HOSPITALITY. www.energia.ie
Energy Efficiency HOSPITALITY www.energia.ie Your chance to reduce your business energy usage by as much as 20%! 20% is a significant figure and reducing your energy bill by this amount could make a real
Bring the fresh in. Dedicated Outside Air Systems
Bring the fresh in. Dedicated Outside Air Systems The inside story on outside air. On average, we breathe in 3,400 gallons of air each day. Ambient indoor air pollution is a major problem, affecting health
NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!
Flexit SL4 R Air Handling Unit with rotating recovery system Energy-efficient New control system NEW! Patent applied for! - Simple settings - Flexible installation - User friendly F O R H E A LT H Y I
Transformer oil cooler ALFA A02
A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using
The risk assessment of fire damper installations
The risk assessment of fire damper installations June 2010 Paul White OVERVIEW OVERVIEW The purpose of this presentation is to highlight that fire dampers form a key part of the passive fire protection
Composite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
Direct steam injection humidifiers
Direct steam injection humidifiers Direct steam injection gives quality control of air humidity. Research and development in separation, the use of lightweight stainless steel combined a constant temperature