Centrifugal Fans direct driven with scroll. Issue 1.3 November 2012

Size: px
Start display at page:

Download "Centrifugal Fans direct driven with scroll. Issue 1.3 November 2012"

Transcription

1 Centrifugal Fans direct driven with scroll ssue 1.3 November 212 2

2 The overall picture will decide Complete systems by Nicotra Gebhardt Depending on the model of the fan, the efficiency grade N set in accordance with the Er Directive must be achieved from 213 and 215 respectively. Efficiency grade N to Er-Directive Year Centrifugal fans with backward curved blades without housing static The efficiency grade designates a parameter in the calculation of the target energy efficiency of a fan depending on the electric input power when operating at the optimal energy efficiency point. The figure of parameter N corresponds to the target energy efficiency with a power of 1 kw. To make the selection easier for our customers, we offer complete systems as defined by the Er Directive! n order to compare the systems, the total efficiency η e of the fan without speed regulation is considered. h e = u(s) / e with housing static total Centrifugal fans with forward curved blades with housing static total h e = Total efficiency u(s) = Fan gas power when operating at the optimal energy efficiency point e = Electric input power when operating at the optimal energy efficiency point f the system has speed regulation, it will be taken into account with the part load compensation factor C c (see below): Nicotra Gebhardt can supply complete systems in all product categories which meet the Er requirements. We offer highly efficient fan systems with matching components and high efficiency drives belt and direct drive. with integrated or external control to regulate speed. with EC standard motors (E2) or internal rotor motors with brushless DC technology. and with C external rotor motors or brushless DC external rotor motors. Building blocks for best values Thanks to the decades-long experience of Nicotra Gebhardt all the components of our fans contribute to their high performance. mpellers and blades are optimised for turbulence and therefore particularly efficient. n example: With the latest development, the RLM Evo impeller, the free-running centrifugal fans of Nicotra Gebhardt achieve system efficiency grades never reached before. n addition, the brushless DC drives which Nicotra Gebhardt offers for its direct drive fans improve the system efficiency grades. The fan technology of Nicotra Gebhardt delivers highly efficient systems for all applications. η e = u(s) / e(d) C c ed = nput power of speed regulator when operating at the optimal energy efficiency point C c = part load compensation factor without speed regulation: C c = 1 with speed regulation ed 5 kw: C c = 1.4 with speed regulation ed < 5 kw: C c = -.3 ln( ed ) η e n order to take the speed regulation into account via the part load compensation factor C c, the following mathematical losses arise in accordance with the formula prescribed by Er for the following typical motor powers: ed = 4. kw: C c = 1.5 (5 %) ed = 2.2 kw: C c = 1.6 (6 %) ed =. kw: C c = 1.1 (1 %) C c η m η T η r e(d) e u(s)

3 C 6 C 8 C TEX Voltage Brushless-DC External nverter Forward curved blades galvanised sheet steel Backward curved blades coated steel Galvanised steel Coated steel Single inlet Double inlet Er status TEM/REM REM: 22. TEM: REM: RZM RZ RZ DD DDMB DDM Flow rate Media temperature Speed control mpeller Casing material nlet type B

4 Nicotra Gebhardt technologies like... utomated manufacture of compact scroll and impeller with forward curved blades Own C and Brushless-DC motor production for optimal tuniung of motor and fan! proselect Simple and reliable selection proselect is a technical selection program that allows you to configure your own individually designed fan. t provides you with the opportunity to choose from the entire range of fan types and their associated options. The result from proselect is the provision of all the technical data for your fan, including sound level data, dimension specifications and accessories. part from that, as a registered user, your purchase prices are provided. dditionally fully dimensioned drawings in dxf format are available, which can be downloaded and transferred straight into your CD system. So that you can be sure. Models and options that are technically not permissible, are automatically excluded in proselect. So there is no chance that you will configure a wrong device option. You can register as a proselect user with us, which enables us to offer you faster order processing. What this means for you is: The complete configuration of your fan with its associated system accessories and belt drive layout. The possibility to produce fans that operate via a frequency inverter. The option of saving your own fan configuration on our server. The opportunity to modify your saved configuration, even over the phone to your Nicotra Gebhardt representative. 2

5 High performance centrifugal fans DDM double width, double inlet, (DWD), with built-in, optimised external rotor motor, made of galvanised sheet steel; available in various models; mpeller with forward curved blades of galvanised steel plate Fittings ccessories TEM REM RZM DDMB RZ RZ DD DDM High performance centrifugal fans DDMB double width, double inlet, (DWD), with built-in, brushless DC external rotor motor and external commutation unit, made of galvanised sheet steel; available in various models; mpeller with forward curved blades of galvanised steel plate High performance centrifugal fans DD double width, double inlet, (DWD), built-in, optimised internal rotor motor, made of galvanised sheet steel; available in various models; mpeller with forward curved blades of galvanised steel plate High performance centrifugal fans RZ rotavent double inlet, with built-in, low-slip external rotor motor, made of galvanised sheet steel or welded and coated, with multi position feet and connecting flange at discharge; mpeller with true aerofoil blades, welded and painted system rotavent High performance centrifugal fans RZ rotavent double inlet, with built-in, brushless DC external rotor motor and external commutation unit, made of galvanised sheet steel; with multi position feet and connecting flange at discharge; mpeller with true aerofoil blades, welded and painted system rotavent High performance centrifugal fans RZM rotavent double inlet, fan with directly coupled motor fitted on pedestal and base frame, made of galvanised sheet steel with heavy duty reinforced side frame, connecting flange at discharge, mpeller with true aerofoil blades, welded and painted system rotavent High performance centrifugal fans REM/TEM single inlet, with flanged EC standard motor out of air stream, in unterschiedlichen usführungsvarianten, mpeller with true aerofoil blades, welded and painted (REM) or forward curved blades of galvanised steel plate (TEM), with or without pedestal for horizontal or vertical mounting Fittings / ccessories complete system accessories fittings and options Technical Description Descriptions Operating limits Notes 3 Technical Description

6 The best fan for your application! DDM range direct driven fans Direct driven centrifugal fans of DDM range with forward curved impeller directly mounted on the external rotor motor are the ideal solution for your applications in the HVC business. The fact of manufacturing by ourselves each fan component the casing, the impeller and motor enables us to create fans that perfectly meet the requirements of high performances and low power consumptions. The wide range of different versions and motor types allows you to find the fan exactly matching what you really need. You anyway get the generally recognized advantages of the direct drive technology : Maintenance free No transmission losses Long fan life time High reliability Low operating costs nd, more, all the additional product advantages of the DDM range are at your fingertips. Compact casing erodynamically optimized in terms of both airflow and design, scrolls are made of galvanized steel and automatically assembled using an innovative procedure, providing a sturdy and long-lasting product. without welding points for no corrosion troubles high precision manufacturing process for high quality product Real forward curved impeller The impeller has been optimized for the best efficiency, match to the special motor features. We manufacture the high performance impellers through a highly automated and innovative production process. low noise level low power consumption Optimized external rotor motor The fan impeller is directly mounted on the motor thus providing efficient motor cooling by the fan airflow. Motor speed can be adjusted either by the use of transformers and TRC regulators. Motors are generally fitted with thermal protector for against overheating. high reliability and efficiency wide range of operative conditions Vibration isolation The vibration isolation pads of the motor shaft ensures a very low noise during fan operation and no transmission of noise and vibrations to the other parts of the fan, making installation more quiet and comfortable. low noise level no noise and vibrations transmitted to the surrounding structures Easy electrical connection ll fans could be provided with connection box, terminal block or loose cable. wiring diagram sticker, placed on each fan, describes the correct electrical connection. fast and easy wiring safe operation 4

7 rogram overview: DDM range This kind of fans are specially conceived for use in dust-free environments, at temperatures up to +4 C, or higher on selected models. The performance data have been obtained in a laboratory registered by MC for MC 21/ air performance testing. Data are not certified by MC. Fan range DDM mpeller size (width and diameter) up to 15 Speed variation either by step-transformers or stepless External rotor motor with integrated thermal protector The variety of DDM We have the right fan for all your application! Many different sizes, versions and motor types are available in the DDM range. Fan models suitable for 6Hz supply are available ir Flow up to 12, Static pressure up to 8 Version Description Figure DDM Lap-jointed scroll made from galvanized steel and forward curved blades impeller directly mounted on an external rotor motor. +SCT with terminal box mounted +FL with discharge flange mounted +SB with housing feet either mounted or loose 5

8 DDM-12/126 Direct driven centrifugal fans / DDM / 25 DDM 12/126 F 1F 2 2V db V 5 Hz 35 3 DDM 12/126 F 1F 2 2V 23 V 6 Hz 7 db [1] [LO] [H] [2] [LO] 5 [H]

9 DDM-12/126 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 12/126 W Hz W 1/min F 1F 2 2V * [1/2] ~ 5/ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 12/126 μf V C kg kg/m³ F 1F 2 2V B EXT B 6M21 (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 12/127 F 1F 2 2V ±1 8 ±

10 DDM-133/126 Direct driven centrifugal fans / DDM / DDM 133/126 F7 1F 2 4V +FL db V 5 Hz V [B1] DDM 133/126 F7 1F 2 4V +FL 23 V 6 Hz db V [B2]

11 DDM-133/126 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 133/126 W Hz W 1/min F7 1F 2 4V +FL * [B1/B2] 6 2 1~ 5/ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 133/126 μf V C kg kg/m³ F7 1F 2 4V +FL B NT B 6M27 (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 133/127 F7 1F 2 4V +FL Ø

12 DDM-133/1 Direct driven centrifugal fans / DDM / 4 DDM 133/1 6 1F 2 1V +FL +SCT 23 V 5 Hz 5 DDM 133/1 6 1F 2 1V +FL +SCT 23 V 6 Hz db V V V 1V [C1] db [C2] V V V 5 1V DDM 133/1 C 1F 2 1V +FL 23 V 5 Hz 5 DDM 133/1 C 1F 2 1V +FL 23 V 6 Hz db [C3] db [C4] V 55 14V 62 18V 67 23V DDM 133/1 C6 1F 2 4V +FL 23 V 5 Hz db V [C5] DDM 133/1 C6 1F 2 4V +FL 23 V 6 Hz db 63 6 [C6] V

13 DDM-133/1 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 133/1 W Hz W 1/min 6 1F 2 1V +FL (2) [C1/C2] 2 1~ 5/ C 1F 2 1V +FL (2) [C3/C4] 2 1~ 5/ C6 1F 2 4V +FL * [C5/C6] 6 2 1~ 5/ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 133/1 μf V C kg kg/m³ 6 1F 2 1V +FL F NT B 612LT C 1F 2 1V +FL B EXT B 612FW C6 1F 2 4V +FL B EXT B 612YC (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 133/1 6 1F 2 1V +FL Ø DDM 133/1 C 1F 2 1V +FL Ø DDM 133/1 C6 1F 2 4V +FL Ø

14 DDM-146/1 Direct driven centrifugal fans / DDM / DDM 146/1 8 1F 2 1V +FL db 23 V 5 Hz [D1] V V V V DDM 146/1 C2 1F 2 1V +FL 66 db 23 V 5 Hz [D3] V V 53 14V 57 1V DDM 146/1 C2 1F 2 1V +FL 23 V 6 Hz 77 db [D4] DDM 146/1 C5 1F 4 4V +FL 23 V 5 Hz db [D5] DDM 146/1 C5 1F 4 4V +FL 23 V 6 Hz 63 db [D6] V 57 14V 61 18V 6623V

15 DDM-146/1 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 146/1 W Hz W 1/min 8 1F 2 1V +FL (2) [D1] ~ C2 1F 2 1V +FL (1) [D3/D4] ~ 5/ C5 1F 4 1V +FL (2) [D5/D6] 2 4 1~ 5/ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 146/1 μf V C kg kg/m³ 8 1F 2 1V +FL F NT B 612Z C2 1F 2 1V +FL F EXT B 612YU C5 1F 4 1V +FL B NT B 612MH (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 146/1 8 1F 2 1V +FL Ø DDM 146/1 C2 1F 2 1V +FL Ø DDM 146/1 C5 1F 2 1V +FL Ø

16 DDM-225/24 Direct driven centrifugal fans / DDM / DDM 225/24 E6G334 1F 4 1V +FL +SCT S L 4 W [E1] 7 db 23 V 5 Hz 5 4 DDM 225/24 E6G334 1F 4 1V +FL +SCT S [E2] 23 V 6 Hz db 2 1 1V V V V V 56 1V 56 18V V DDM 225/24 E6G345 1F 4 1V +FL +SCT db [E3] 23 V 5 Hz V V V 66 1V

17 DDM-225/24 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 225/24 W Hz W 1/min E6G334 1F 4 1V +FL +SCT S (2) [E1/E2] 3 4 1~ 5/ E6G345 1F 4 1V +FL +SCT (2) [E3/E4] ~ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 225/24 μf V C kg kg/m³ E6G334 1F 4 1V +FL +SCT S F EXT B 612CT E6G345 1F 4 1V +FL +SCT F EXT B 6M212 (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 225/24 E6G334 1F 4 1V +FL +SCT S Ø DDM 225/24 E6G345 1F 4 1V +FL +SCT Ø

18 DDM-28/24 Direct driven centrifugal fans / DDM / L W DDM 28/24 E6G3 1F 4 1V +SCT V 81 db V 5 Hz V [F1] V 14V L DDM 28/24 E6G376 3F 4 2V +SCTV W7 77 4/4 V 5 Hz db [F3] V Y 4V

19 DDM-28/24 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 28/24 W Hz W 1/min E6G3 1F 4 1V +SCT (2) [F1] 6 4 1~ E6G376 3F 4 1V +SCT (1) [F3] 4 3~ D/Y Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 28/24 μf V C kg kg/m³ E6G3 1F 4 1V +SCT F EXT B 612XE E6G376 3F 4 1V +SCT 55 F EXT B 6M2121 (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 28/24 E6G334 1F 4 1V +SCT DDM 28/24 E6G376 1F 4 1V +SCT

20 DDM-7/7 Direct driven centrifugal fans / DDM / DDM 7/7 E6G345 1F 4 1V +SCT 64 [G1] db V 5 Hz DDM 7/7 E6G345 1F 4 1V +SCT 23 V 6 Hz V 63 14V 18V 23V 81 1V 6314V 68 18V 23V [G2] 78 db DDM 7/7 E6G334 1F 4 1V +SCT 62 [G3] db 23 V 5 Hz V 6 14V 18V 76 23V DDM 7/7 E6G334 1F 4 1V +SCT V 6 Hz V V V 1V [G4] 76 db DDM 7/7 E5G342 1F 4 1V +SCT 23 V 5 Hz [G5] 2 db V 61 14V 66 18V 7 23V

21 DDM-7/7 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 7/7 W Hz W 1/min E6G345 1F 4 1V +SCT (2) [G1/G2] ~ 5/ E6G334 1F 4 1V +SCT (2) [G3/G4] 3 4 1~ 5/ E5G342 1F 4 1V +SCT (2) [G5] ~ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 7/7 μf V C kg kg/m³ E6G345 1F 4 1V +SCT F EXT B 6M2WL E6G334 1F 4 1V +SCT F EXT B 6M2Y8 E5G342 1F 4 1V +SCT F EXT B 6M2L7 (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 7/7 E6G345 1F 4 1V +SCT DDM 7/7 E6G334 1F 4 1V +SCT DDM 7/7 E5G342 1F 4 1V +SCT

22 DDM-7/7 Direct driven centrifugal fans / DDM / DDM 7/7 E5G331 1F 4 1V +SCT 23 V 5 Hz 67 [G7] 66 db DDM 7/7 E5G331 1F 4 1V +SCT db [G8] 23 V 6 Hz V V 1V 54 14V DDM 7/7 E6G337 1F 4 3V +SCT [G] 23 V 5 Hz db [LO] 6 [ME] [H] 25 DDM 7/7 E5G341 1F 4 3V +SCT 23 V 5 Hz db [G11] [LO] 63[ME] 67 [H]

23 DDM-7/7 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 7/7 W Hz W 1/min E5G331 1F 4 1V +SCT (2) [G7/G8] ~ 5/ E6G337 1F 4 3V +SCT * [G] ~ E5G341 1F 4 3V +SCT * [G11] ~ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 7/7 μf V C kg kg/m³ E5G331 1F 4 1V +SCT F EXT B 6M2M E6G337 1F 4 3V +SCT F EXT B 6M22U E5G341 1F 4 3V +SCT F EXT B 6M2U8 (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 7/7 E5G331 1F 4 1V +SCT DDM 7/7 E6G337 1F 4 3V +SCT DDM 7/7 E5G341 1F 4 3V +SCT

24 DDM-7/7 Direct driven centrifugal fans / DDM / 25 2 DDM 7/7 E6G33 3F 4 1V +SCT [G13] 23/4 V 5 Hz db DDM 7/7 E6G33 3F 4 1V +SCT 23/4 V 6 Hz 76 db [G14] V V DDM 7/7 E5G343 3F 4 1V +SCT 23/4 V 5 Hz db [G15] 3 25 DDM 7/7 E5G343 3F 4 1V +SCT 254/44 V 6 Hz [G16] db V V DDM 7/7 E5G332 1F 6 1V +SCT [G17] 64 db V 5 Hz 67 1V 57 14V 62 18V 23V DDM 7/7 E5G332 1F 6 1V +SCT 23 V 6 Hz 66 [G18] 67 db

25 DDM-7/7 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 7/7 W Hz W 1/min E6G33 3F 4 1V +SCT * [G13/G14] 3 4 3~ D/Y 5/ E5G343 3F 4 1V +SCT * [G15/G16] ~ D/Y 5/ E5G332 1F 6 1V +SCT (2) [G17/G18] 6 1~ 5/ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 7/7 μf V C kg kg/m³ E6G33 3F 4 1V +SCT 55 F EXT B 6M2WM E5G343 3F 4 1V +SCT 55 F EXT B 6M22H E5G332 1F 6 1V +SCT F EXT B 6M2Z4 (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 7/7 E6G33 3F 4 1V +SCT DDM 7/7 E5G343 3F 4 1V +SCT DDM 7/7 E5G332 1F 6 1V +SCT

26 DDM-7/ Direct driven centrifugal fans / DDM / 25 DDM 7/ E6G334 1F 4 1V +SCT 23 V 5 Hz 35 DDM 7/ E6G334 1F 4 1V +SCT 23 V 6 Hz [H1] db db [H2] V 57 14V 67 18V 23V DDM 7/ E6G345 1F 4 1V +SCT 23 V 5 Hz db [H3] DDM 7/ E6G345 1F 4 1V +SCT 23 V 6 Hz 76 [H4] 77 db V 6 14V 68 18V 23V

27 DDM-7/ Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 7/ W Hz W 1/min E6G334 1F 4 1V +SCT (2) [H1/H2] 3 4 1~ 5/ E6G345 1F 4 1V +SCT (2) [H3/H4] ~ 5/ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 7/ μf V C kg kg/m³ E6G334 1F 4 1V +SCT F EXT B 6M2L6 E6G345 1F 4 1V +SCT F EXT B 6M25X (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 7/ E6G334 1F 4 1V +SCT DDM 7/ E6G345 1F 4 1V +SCT

28 DDM-/7 Direct driven centrifugal fans / DDM / DDM /7 E6G351 1F 4 1V +SCT DDM /7 E6G345 1F 4 1V +SCT 23 V 5 Hz db 23 V 5 Hz [1] V 61 14V 18V 78 23V V V db [3] 76 18V V DDM /7 E6G351 1F 4 1V +SCT 23 V 6 Hz db [2] DDM /7 E6G334 1F 4 1V +SCT 23 V 5 Hz db [5] V V V 1V

29 DDM-/7 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM /7 W Hz W 1/min E6G351 1F 4 1V +SCT (2) [1/2] ~ 5/ E6G345 1F 4 1V +SCT (2) [3] ~ E6G334 1F 4 1V +SCT (2) [5] 3 4 1~ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM /7 μf V C kg kg/m³ E6G351 1F 4 1V +SCT F EXT B 6M2M E6G345 1F 4 1V +SCT F EXT B 6M22 E6G334 1F 4 1V +SCT F EXT B 6M2N (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM /7 E6G351 1F 4 1V +SCT DDM /7 E6G345 1F 4 1V +SCT DDM /7 E6G334 1F 4 1V +SCT

30 DDM-/7 Direct driven centrifugal fans / DDM / 4 35 DDM /7 E6G352 1F 4 3V +SCT 23 V 5 Hz [7] db [LO] 6 [ME] 7 [H] DDM /7 E6G232 1F 4 3V db 23 V 5 Hz [] DDM /7 E6G232 1F 4 3V 23 V 6 Hz 77 [1] 77 db [LO] [ME] [H] 77 [LO] [ME] 68 [H] DDM /7 E6G333 1F 6 1V +SCT db 23 V 5 Hz [11] 25 2 DDM /7 E6G333 1F 6 1V +SCT 23 V 6 Hz 68 db [12] V 54 14V 67 18V 23V

31 DDM-/7 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM /7 W Hz W 1/min E6G352 1F 4 3V +SCT * [7] ~ E6G232 1F 4 3V * [/1] ~ 5/ E6G333 1F 6 1V +SCT (2) [11/12] 2 6 1~ 5/ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM /7 μf V C kg kg/m³ E6G352 1F 4 3V +SCT F EXT B 6M2U E6G232 1F 4 3V F EXT B 6M2ZN E6G333 1F 6 1V +SCT F EXT B 6M2H8 (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM /7 E6G352 1F 4 3V +SCT DDM /7 E6G232 1F 4 3V +SCT DDM /7 E6G333 1F 6 1V +SCT

32 DDM-/7 Direct driven centrifugal fans / DDM / DDM /7 E6G336 1F 6 3V +SCT 23 V 5 Hz [13] 68 db LW7 DDM /7 E6G336 1F 6 3V +SCT 23 V 6 Hz db [14] 7 [H] [LO] 56 [ME] [H] 5 [ME] 6 [LO] DDM /7 E6G363 3F 4 1V +SCT 23/4 V 5 Hz DDM /7 E6G363 3F 4 1V +SCT 7 254/44 V 6 Hz 81 db dB [15] [16] 86 44V V DDM /7 E6G33 3F 4 1V +SCT 23/4 V 5 Hz 76 db [17] DDM /7 E6G33 3F 4 1V +SCT 23/4 V 6 Hz 76 db [18] 76 4V V

33 DDM-/7 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM /7 W Hz W 1/min E6G336 1F 6 3V +SCT * [13/14] 2 6 1~ 5/ E6G363 3F 4 1V +SCT * [15/16] ~ D/Y 5/ E6G33 3F 4 1V +SCT * [17/18] 3 4 3~ D/Y 5/ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM /7 μf V C kg kg/m³ E6G336 1F 6 3V +SCT F EXT B 6M2W E6G363 3F 4 1V +SCT 55 F EXT B 612WT E6G33 3F 4 1V +SCT 55 F EXT B 6M2WR (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM /7 E6G336 1F 6 3V +SCT DDM /7 E6G363 3F 4 1V +SCT DDM /7 E6G33 3F 4 1V +SCT

34 DDM-/7 TGHT Direct driven centrifugal fans / DDM / 35 DDM /7 TGHT E6G334 1F 4 1V +SCT 23 V 5 Hz 3 db 25 [J1] V V V 1V DDM /7 TGHT E6G345 1F 4 1V +SCT 64 7 db 23 V 5 Hz [J3] V 63 14V 18V 7 23V DDM /7 TGHT E6G345 1F 4 1V +SCT 8 db [J4] V 6 Hz

35 DDM-/7 TGHT Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM /7 TGHT W Hz W 1/min E6G334 1F 4 1V +SCT (2) [J1] 3 4 1~ E6G345 1F 4 1V +SCT (2) [J3/J4] ~ 5/ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM /7 TGHT μf V C kg kg/m³ E6G334 1F 4 1V +SCT F EXT B 6M2WX E6G345 1F 4 1V +SCT F EXT B 6M2WY (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM /7 TGHT E6G334 1F 4 1V +SCT DDM /7 TGHT E6G345 1F 4 1V +SCT

36 DDM-/ Direct driven centrifugal fans / DDM / 4 DDM / E6G3 1F 4 1V +SCT 23 V 5 Hz 77 db 5 4 DDM / E6G3 1F 4 1V +SCT 23 V 7 db 6 Hz [K2] [K1] V 66 14V 18V 8 23V DDM / E6G351 1F 4 1V +SCT 76 db 23 V 5 Hz [K3] V V V 67 1V DDM / E6G253 1F 4 1V 23 V 5 Hz [K5] 77 db V 61 14V 7 18V 77 23V DDM / E6G253 1F 4 1V V 6 Hz 77 db [K6]

37 DDM-/ Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM / W Hz W 1/min E6G3 1F 4 1V +SCT (2) [K1/K2] 6 4 1~ 5/ E6G351 1F 4 1V +SCT (2) [K3] ~ E6G253 1F 4 1V (2) [K5/K6] ~ 5/ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM / μf V C kg kg/m³ E6G3 1F 4 1V +SCT F EXT B 6M2Z E6G351 1F 4 1V +SCT F EXT B 6M2H5 E6G253 1F 4 1V F EXT B 6M2R8 (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM / E6G3 1F 4 1V +SCT DDM / E6G351 1F 4 1V +SCT DDM / E6G253 1F 4 1V +SCT

38 DDM-/ Direct driven centrifugal fans / DDM / DDM / E6G345 1F 4 1V +SCT 23 V 5 Hz 76 db 77 [K7] 7 23V V 61 14V 67 1V DDM / E6G334 1F 4 1V +SCT 23 V 5 Hz V [K] 68 db 23V V V DDM / E6G352 1F 4 3V +SCT 23 V 5 Hz [LO] 5 76 db [K11] [ME] 76 [H]

39 DDM-/ Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM / W Hz W 1/min E6G345 1F 4 1V +SCT (2) [K7] ~ E6G334 1F 4 1V +SCT (2) [K] 3 4 1~ E6G352 1F 4 3V +SCT * [K11] ~ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM / μf V C kg kg/m³ E6G345 1F 4 1V +SCT F EXT B 6M2XN E6G334 1F 4 1V +SCT F EXT B 6M2K1 E6G352 1F 4 3V +SCT F EXT B 6M2W (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM / E6G345 1F 4 1V +SCT DDM / E6G334 1F 4 1V +SCT DDM / E6G352 1F 4 3V +SCT

40 DDM-/ Direct driven centrifugal fans / DDM / DDM / E6G255 1F 4 3V 23 V 7 5 Hz db 7 7 [K13] DDM / E6G255 1F 4 3V 23 V 6 Hz [LO] [ME] 78 [H] 85 [LO] [ME] 76 [H] [K14] 83 db DDM / E6G363 3F 4 1V +SCT 23/4 V 5 Hz 77 [K15] 78 db DDM / E6G363 3F 4 1V +SCT 254/44 V 6 Hz 7 db [K16] V V DDM / E6G342 1F 6 1V +SCT V Hz [K17] 25 DDM / E6G342 1F 6 1V +SCT 23 V 68 6 Hz 7 db db [K18] V 56 14V 64 18V 23V

41 DDM-/ Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM / W Hz W 1/min E6G255 1F 4 3V * [K13/K14] ~ 5/ E6G363 3F 4 1V +SCT * [K15/K16] ~ D/Y 5/ E6G342 1F 6 1V +SCT (2) [K17/K18] ~ 5/ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM / μf V C kg kg/m³ E6G255 1F 4 3V F EXT B 6M27 E6G363 3F 4 1V +SCT 55 F EXT B 6M28 E6G342 1F 6 1V +SCT F EXT B 6M2NM (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM / E6G255 1F 4 3V DDM / E6G363 3F 4 1V +SCT DDM / E6G342 1F 6 1V +SCT

42 DDM-/ Direct driven centrifugal fans / DDM / DDM / E6G333 1F 6 1V +SCT 23 V 5 Hz [K1] 68 db DDM / E6G333 1F 6 1V +SCT 23 V 6 Hz 67 db 68 [K2] V 51 14V 5 18V 67 23V DDM / E6G336 1F 6 3V +SCT 23 V 5 Hz [K21] 67dB 68 [LO] 56 [ME] 61 [H] DDM / E6G336 1F 6 3V +SCT 23 V 6 Hz db 67 [K22] 58 5 [ME] 57 [LO] [H] DDM / E6G343 3F 6 1V +SCT 23/4 V 5 Hz [K23] 25 2 DDM / E6G343 3F 6 1V +SCT 23/4 V 6 Hz [K24] 1 db db V V

43 DDM-/ Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM / W Hz W 1/min E6G333 1F 6 1V +SCT (2) [K1/K2] 2 6 1~ 5/ E6G336 1F 6 3V +SCT * [K21/K22] 2 6 1~ 5/ E6G343 3F 6 1V +SCT * [K23/K24] ~ D/Y 5/ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM / μf V C kg kg/m³ E6G333 1F 6 1V +SCT F EXT B 6M2M2 E6G336 1F 6 3V +SCT F EXT B 6M2WU E6G343 3F 6 1V +SCT 44 F EXT B 6M2G2 (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM / E6G333 1F 6 1V +SCT DDM / E6G336 1F 4 3V +SCT DDM / E6G343 3F 6 1V +SCT

44 DDM-/ TGHT Direct driven centrifugal fans / DDM / DDM / TGHT E6G345 1F 4 1V +SCT db 23 V 5 Hz [L1] V V

45 DDM-/ TGHT Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM / TGHT W Hz W 1/min E6G345 1F 4 1V +SCT (2) [L1] ~ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM / TGHT μf V C kg kg/m³ E6G345 1F 4 1V +SCT F EXT B 6M2L8 (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM / TGHT E6G345 1F 4 1V +SCT

46 DDM-1/8 Direct driven centrifugal fans / DDM / DDM 1/8 E6G3 1F 4 1V +SCT db V 7 14V 23 V 5 Hz 77 [M1] V V DDM 1/8 E6G364 1F 4 1V +SCT 23 V 5 Hz V V [M3] db V 7 23V DDM 1/8 E6G253 1F 4 1V 76 [M5] 23 V 5 Hz 76 db V 1 14V V V

47 DDM-1/8 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 1/8 W Hz W 1/min E6G3 1F 4 1V +SCT (2) [M1] 6 4 1~ E6G364 1F 4 1V +SCT (2) [M3] ~ E6G253 1F 4 1V (2) [M5] ~ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 1/8 μf V C kg kg/m³ E6G3 1F 4 1V +SCT F EXT B 612Z E6G364 1F 4 1V +SCT F EXT B 6M2X4 E6G253 1F 4 1V F EXT B 6M25N (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 1/8 E6G3 1F 4 1V +SCT DDM 1/8 E6G364 1F 4 1V +SCT DDM 1/8 E6G253 1F 4 1V

48 DDM-1/8 Direct driven centrifugal fans / DDM / 5 4 DDM 1/8 E6G2 1F 4 3V [M7] 76 db 23 V 5 Hz 77 3 [H] [ME] [LO] DDM 1/8 E6G363 3F 4 1V +SCT 77 23/4 V 5 Hz [M] db 7 3 4V

49 DDM-1/8 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 1/8 W Hz W 1/min E6G2 1F 4 3V * [M7] ~ E6G363 3F 4 1V +SCT * [M] ~ D/Y Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 1/8 μf V C kg kg/m³ E6G2 1F 4 3V F EXT B 6125 E6G363 3F 4 1V +SCT 55 F EXT B 6M2X (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 1/8 E6G2 1F 4 3V DDM 1/8 E6G363 3F 4 1V +SCT

50 DDM-1/8 Direct driven centrifugal fans / DDM / DDM 1/8 E6G362 1F 6 1V +SCT V 5 Hz db 67 7 [M11] V 63 14V 7 18V 23V DDM 1/8 E6G362 1F 6 1V +SCT db 23 V 6 Hz 25 [M12] DDM 1/8 E6G342 1F 6 1V +SCT [M13] 66 db 23 V 5 Hz V 67 23V V V

51 DDM-1/8 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 1/8 W Hz W 1/min E6G362 1F 6 1V +SCT (2) [M11/M12] ~ 5/ E6G342 1F 6 1V +SCT (2) [M13] ~ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 1/8 μf V C kg kg/m³ E6G362 1F 6 1V +SCT F EXT B 6M2N E6G342 1F 6 1V +SCT F EXT B 6M2WZ (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 1/8 E6G362 1F 6 1V +SCT DDM 1/8 E6G342 1F 6 1V +SCT

52 DDM-1/8 Direct driven centrifugal fans / DDM / L W DDM 1/8 E6G261 1F 6 3V 7 76 db [M15] V 5 Hz [LO] [ME] 7[H] DDM 1/8 E6G344 1F 6 3V +SCT 23 V 5 Hz db db [M1] 7 [M17] [LO] DDM 1/8 E6G343 3F 6 1V +SCT 23/4 V 5 Hz 4V [ME] [H] L W7 3 DDM 1/8 E6G343 3F 6 1V +SCT 254/44 V 6 Hz db 25 [M2] V

53 DDM-1/8 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 1/8 W Hz W 1/min E6G261 1F 6 3V * [M15] ~ E6G344 1F 6 3V +SCT * [M17] ~ E6G343 3F 6 1V +SCT * [M1/M2] ~ D/Y 5/ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 1/8 μf V C kg kg/m³ E6G261 1F 6 3V F EXT B 6M2L E6G344 1F 6 3V +SCT F EXT B 6M24 E6G343 3F 6 1V +SCT 44 F EXT B 6M2XC (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 1/8 E6G261 1F 6 3V DDM 1/8 E6G344 1F 6 3V +SCT DDM 1/8 E6G343 3F 6 1V +SCT

54 DDM-1/1 Direct driven centrifugal fans / DDM / L W DDM 1/1 E6G3 1F 4 1V +SCT [N1] V V 5 Hz 8 db 23V V 7 1 1V DDM 1/1 E6G2 1F 4 1V 23 V 5 Hz [N3] 8 db 14V 23V DDM 1/1 E6G2 1F 4 1V 22 V 6 Hz V 65 1V [N6] 81 db 76 18V V DDM 1/1 E6G364 1F 4 1V +SCT 23 V 5 Hz [N5] 4 db 3 23V V V 62 1V

55 DDM-1/1 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 1/1 W Hz W 1/min E6G3 1F 4 1V +SCT (2) [N1] 6 4 1~ E6G2 1F 4 1V (2) [N3/N4] 6 4 1~ 5/ E6G364 1F 4 1V +SCT (2) [N5] ~ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 1/1 μf V C kg kg/m³ E6G3 1F 4 1V +SCT F EXT B 6M2Z6 E6G2 1F 4 1V F EXT B 6M2CY E6G364 1F 4 1V +SCT F EXT B 6M2 (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 1/1 E6G3 1F 4 1V +SCT DDM 1/1 E6G2 1F 4 1V DDM 1/1 E6G364 1F 4 1V +SCT

56 DDM-1/1 Direct driven centrifugal fans / DDM / 5 4 DDM 1/1 E6G253 1F 4 1V 23 V [N7] 5 Hz db V 78 18V V 68 1V DDM 1/1 E6G2 1F 4 3V 23 V 5 Hz [N] 78 db 78 3 [H] 78 2 [ME] 1 [LO]

57 DDM-1/1 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 1/1 W Hz W 1/min E6G253 1F 4 1V (2) [N7] ~ E6G2 1F 4 3V * [N] ~ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 1/1 μf V C kg kg/m³ E6G253 1F 4 1V F EXT B 6M2XF E6G2 1F 4 3V F EXT B 6M2Z8 (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 1/1 E6G253 1F 4 1V DDM 1/1 E6G2 1F 4 3V

58 DDM-1/1 Direct driven centrifugal fans / DDM / 5 4 DDM 1/1 M 3F 4 2V +SCT [N11] 82 db 4/4 V 5 Hz V Y 84 4V g DDM 1/1 E6G376 3F 4 2V 4/4 V 5 Hz 78 7 [N13] 8 db V g V Y

59 DDM-1/1 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 1/1 W Hz W 1/min M 3F 4 2V +SCT (2)/(3) [N11] 1 4 3~ D/Y E6G376 3F 4 2V +SCT (1) [N13] 4 3~ D/Y Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 1/1 C kg kg/m³ M 3F 4 2V +SCT 54 F NT B 6M2122 E6G376 3F 4 2V +SCT 55 F EXT B 6M21Y (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 1/1 M 3F 4 2V +SCT DDM 1/1 E6G376 3F 4 2V +SCT

60 DDM-1/1 Direct driven centrifugal fans / DDM / 25 2 DDM 1/1 E6G362 1F 6 1V +SCT 23 V 5 Hz [N15] db DDM 1/1 E6G362 1F 6 1V +SCT 23 V 6 Hz 76 [N16] 77 db V 64 14V 7 18V 23V V V V 1V DDM 1/1 E6G342 1F 6 1V +SCT 23 V 5 Hz db [N17] DDM 1/1 E6G261 1F 6 3V +SCT 23 V 5 Hz 7 [LO] [ME] 76 [H] [N1] 7 db DDM 1/1 E6G261 1F 6 3V +SCT 23 V 6 Hz [LO] [ME] [H] [N2] 77 db

61 DDM-1/1 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 1/1 W Hz W 1/min E6G362 1F 6 1V +SCT (2) [N15/N16] ~ 5/ E6G342 1F 6 1V +SCT (2) [N17] ~ E6G261 1F 6 3V * [N1/N2] ~ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 1/1 μf V C kg kg/m³ E6G362 1F 6 1V +SCT F EXT B 6M2N1 E6G342 1F 6 1V +SCT F EXT B 6M2G E6G261 1F 6 3V F EXT B 6M2FF (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 1/1 E6G362 1F 6 1V +SCT DDM 1/1 E6G342 1F 6 1V +SCT DDM 1/1 E6G261 1F 6 3V

62 DDM-1/1 Direct driven centrifugal fans / DDM / L 25 W DDM 1/1 E6G344 1F 6 3V +SCT 23 V 5 Hz [N21] 68 db [ME] [H] [LO] DDM 1/1 E6G366 3F 6 1V +SCT 23/4 V 5 Hz [N23] db DDM 1/1 E6G366 3F 6 1V +SCT 254/44 V 6 Hz db [N24] V V DDM 1/1 E6G343 3F 6 1V +SCT 68 23/4 V 5 Hz db [N25] DDM 1/1 E6G343 3F 6 1V +SCT 254/44 V 6 Hz [N26] db 44V V

63 DDM-1/1 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 1/1 W Hz W 1/min E6G344 1F 6 3V +SCT * [N21] ~ E6G366 3F 6 1V +SCT * [N23/N24] ~ D/Y 5/ E6G343 3F 6 1V +SCT * [N25/N26] ~ D/Y 5/ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 1/1 μf V C kg kg/m³ E6G344 1F 6 3V +SCT F EXT B 6M2XM E6G366 3F 6 1V +SCT 55 F EXT B 6M25T E6G343 3F 6 1V +SCT 44 F EXT B 6M2G3 (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 1/1 E6G344 1F 6 3V +SCT DDM 1/1 E6G366 3F 6 1V +SCT DDM 1/1 E6G343 3F 6 1V +SCT

64 DDM-12/ Direct driven centrifugal fans / DDM / V DDM 12/ E6G3 1F 6 1V +SCT 23 V 5 Hz V 68 [O1] 76 db 18V 76 23V DDM 12/ E6G2 1F 6 1V 23 V 5 Hz 76 [O3] 78 db V 5 14V DDM 12/ E6G3 1F 6 3V +SCT 23 V 5 Hz [O5] db [LO] 7 [ME] [H]

65 DDM-12/ Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 12/ W Hz W 1/min E6G3 1F 6 1V +SCT (2) [O1] ~ E6G2 1F 6 1V (2) [O3] 5 6 1~ E6G3 1F 6 3V +SCT * [O5] 5 6 1~ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 12/ μf V C kg kg/m³ E6G3 1F 6 1V +SCT F EXT B 612N E6G2 1F 6 1V F EXT B 612CL E6G3 1F 6 3V +SCT F EXT B 612C (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 12/ E6G3 1F 6 1V +SCT DDM 12/ E6G2 1F 6 1V DDM 12/ E6G3 1F 6 3V +SCT

66 DDM-12/ Direct driven centrifugal fans / DDM / 35 3 DDM 12/ E6G377 3F 6 1V +SCT 23/4 V 5 Hz 81 [O7] 7 db V

67 DDM-12/ Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 12/ W Hz W 1/min E6G377 3F 6 1V +SCT * [O7] ~ D/Y Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 12/ C kg kg/m³ E6G377 3F 6 1V +SCT 55 F EXT B 6121R (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 12/ E6G377 3F 6 1V +SCT

68 DDM-12/12 Direct driven centrifugal fans / DDM / DDM 12/12 M 3F 4 2V +SCT 4/4 V 5 Hz [1] V 83 23V 28V 4V db DDM 12/12 E6G3 1F 6 1V +SCT 23 V 5 Hz 3 25 [3] db V 14V 66 18V 23V V 63 DDM 12/12 E6G2 1F 6 1V 23 V 5 Hz 7 14V 7 [5] 76 db V V DDM 12/12 E6G2 1F 6 1V 23 V 6 Hz [6] 78 db

69 DDM-12/12 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 12/12 W Hz W 1/min M 3F 4 2V +SCT (2)/(3) [1] ~ D/Y E6G3 1F 6 1V +SCT (2) [3] ~ E6G2 1F 6 1V (2) [5/6] 5 6 1~ 5/ Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 12/12 μf V C kg kg/m³ M 3F 4 2V +SCT 54 F EXT B 6M2123 E6G3 1F 6 1V +SCT F EXT B 612N5 E6G2 1F 6 1V F EXT B 612 (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 12/12 M 3F 4 2V +SCT DDM 12/12 E6G3 1F 6 1V +SCT DDM 12/12 E6G2 1F 6 1V

70 DDM-12/12 Direct driven centrifugal fans / DDM / DDM 12/12 E6G3 1F 6 3V +SCT 23 V 5 Hz 7 7 [LO] 67 [7] db [ME] [H] DDM 12/12 E6G377 3F 6 1V +SCT 23/4 V 5 Hz [] db

71 DDM-12/12 Direct driven centrifugal fans / DDM / Speed control Curves motor power oles hases Connection Mains frequency Max. power Max. current consumption consumption Speed DDM 12/12 W Hz W 1/min E6G3 1F 6 3V +SCT * [7] 5 6 1~ E6G377 3F 6 1V +SCT * [] ~ D/Y Operating Capacitor capacitor voltage Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDM 12/12 μf V C kg kg/m³ E6G3 1F 6 3V +SCT F EXT B 612K2 E6G377 3F 6 1V +SCT 55 F EXT B 612R (1) = Speed controllable via Transformer (2) = Speed controllable via TRC or Transformer (3) = Speed controllable via nverter * = No speed control available [H] High speed, [ME] Medium speed, [LO] Low speed ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDM 12/12 E6G3 1F 6 3V +SCT DDM 12/12 E6G377 3F 6 1V +SCT

72 DDM Direct driven centrifugal fans / DDM / Specifications Specifications High performance centrifugal fan DDM Double width, double inlet (DWD), direct driven forward curved blades fan. Lap-jointed scroll of galvanized steel (EN 1142) assembled through a high technology roller-lock seaming for fan sizes 7 inches and larger, spot-welded scroll of Sendzimir galvanized steel for smaller sizes. Straight cut off plate at fan outlet. mpeller with forward curved blades of galvanized steel, directly mounted on an External Rotor motor for optimal motor cooling and no transmission losses. Open (1/2) or closed (32/44/54/55) motor frame; Motors may be single or three-phase, single or multiple speed, speed-adjustable by voltage regulation through transformers or TRC regulators. Motors suitable for use at 5Hz or 6Hz are available. Built-in thermal devices either in series or wired out is standard fit. Maintenance free self-aligning ball bearings, vibration isolation pads. mpeller dynamically balanced in 6.3, according to SO 14. Different fan options and accessories, motor types and sizes available - see technical data. Fan data Fan type Volume flow Static pressure ir density at fan inlet r kg/m³ ir temperature Max. power consumption Speed Frequency Sound power level ( weighted) Weight t e N f L W m C kw 1/min Hz db kg Fittings / ccessories Outlet flange - O Outlet flexible connection - (sizes 7/7) Mounting feet - O/ (sizes 7/7) Terminal box - O nlet guard -O/ Outlet guard - O/ owder-coating - O TRC electronic regulators - Legend O = Options = ccessory O/ = The item could be delivered as an option or an accessory lease, check availability of each individual option or accessory on each specific fan model.

73 Fittings / ccessories Direct driven centrifugal fans / DDM / ccessories ccessories Flanges ll options and accessories must be specified separately. lease take the technical data and dimensions from the corresponding page of the catalogue. Made from galvanized or painted steel, to connect ducts and system components to the fan outlet side. Dimensions in mm, subject to change. 28 d f f 13 b 13 Ø d1 a 13 e e 13 c DDM a b c d e f 7/ / / /7 TGHT / / TGHT / / / / / Ø d1 Flexible connection Dimensions in mm, subject to change d 13 f f 13 b Ø d1 a 13 e e 13 c DDM a b c d e f 7/ / / /7 TGHT / / TGHT / / / / / Ø d1 Dimensions in mm, subject to change. 224 d f f 13 b 13 Ø d1 a 13 e e 13 c DDM a b c d e f 7/ / / /7 TGHT / / TGHT / / / / / Ø d1

74 Fittings / ccessories Direct driven centrifugal fans / DDM / ccessories Mounting feet Feet made from galvanized steel, either mounted or loose, enable the fan to be installed with a, and 27 orientation. Dimensions in mm, subject to change. w x3 w w x4 s x2 q 11x16 6 v r h x1 w p l DDM h l p q r s v w x1 x2 x3 x4 7/ / / /7 TGHT / / TGHT / / / / / Terminal box Each fan is equipped with a loose cable, a terminal strip or a terminal box (see specific catalog data for details) The terminal box is commonly fitted to the side plate of the fan. t is made of plastic material and provided with cable glands. schematic diagram, always provided with the fan, displays the proper electrical connection. Dimensions in mm, subject to change rotection guards nlet or outlet guards are available as accessories from size 7/7 to 1/1, for bigger sizes and for further information, please contact Nicotra Gebhardt technical department.

75 Fittings / ccessories Direct driven centrifugal fans / DDM / ccessories ncreased corrosion RVM - Single-phase manual regulator Nicotra Gebhardt fans are provided as a standard equipment with a highly efficient corrosion but, in the event of extremely high corrosion risk, additional corrosion s might be required. Following to the application and corrosion stress conditions, special coatings of various types and thickness can be supplied on request. Electronical speed control unit producing a stepless modulated output voltage for fans with speed controlled single phase motors Execution Casing made of impact resistant plastic. Function The speed controller is equipped with an EMC-filter, a turning knob for speed control starting at a fixed rpm-value, an operation indicating light (RVM 5, RVM, RVM 2), and an internal fuse. rticle Max. rotection Temperature number voltage current Frequency range Fuse a b c V Hz C mm mm mm RVM 1,5E K /6 2 +/+4 5X2 1 FST RVM 3E K /6 2 +/+4 5X2 1 FST RVM 5 K /6 54-1/+4 5X2 1 FST RVM K /6 54-1/+4 6,3X32 2 FST RVM 2 K /6 54-1/+4 6,3x32 32 GL Dimensions b a c Wiring Diagram RVM 1.5E, RVM 3E RVM 1.5E, RVM 3E M Motor L N M 23 V/C 5/6 Hz Motor L 23 V/C 5/6 Hz N

76 Fittings / ccessories Direct driven centrifugal fans / DDM / ccessories Wiring Diagram RVM 5, RVM, RVM 2 Capacitor L N C 23 V/C 5/6 Hz + Earth Motor 1 Common 2 Main 3 uxiliary RVT - Three-phase manual regulator Electronical speed control unit producing a stepless modulated output voltage for fans with speed controlled three phase motors. Execution lastic casing with cast aluminium base plate, 54. Function With the control unit a setting of the minimum speed value as well as the maximum speed is provided. t is equipped with an internal overload and, as an option, there are contacts provided for connecting the thermo contacts (TO) in the motor winding. Following to switching the unit on, the controller automatically is operating a softstart of the motor up to the speed which is set by the position of the potentiometer. By turning the potentiometer the motor speed will be changing due to driving it with a varying voltage through phase cutting. rticle number voltage current Frequency rotection Temperature range Fuse a b c V Hz C mm mm mm RVT 3 K /6 54 +/+4 6x32 GF RVT 6 K /6 54 +/+4 6x32 GF RVT K /6 54 +/+4 6x32 GF Dimensions b a c 76

77 Fittings / ccessories Direct driven centrifugal fans / DDM / ccessories Wiring Diagram 4 V Tension max RVT L1 L2 L3 E GND U V W min 1 % Control 4 V / 5 Hz E Motor 3~ Star-delta switch Enclosed selector for star-delta motor configuration for three-phase motors. Execution nsulated polycarbonate module, 66 degree. front mounting, silver front panel, 6 switching angle, terminals accessible both from mounting direction or laterally, data rated according to EC 47. Function 3-position changeover switch for = Motor OFF, Y = STR motor configuration, D = DELT motor configuration. t must be installed between the 3-phase power supply (L1, L2, L3) and a 3-phase controllable motors, having the STR-DELT terminals externally available (U1, V1, W1 and U2, V2, W2 respectively). t provides a safe way to switch between the STR and DELT motor configurations, changing, in this way, between the high (DELT) and low (STR) motor speed. The switch can't be used as STR/DELT motor starter! rticle rotection Temperature number voltage current Frequency range V Hz C M2 K / /+4 Dimensions in mm, subject to change. 2 2 M Wiring Diagram Y L1 L2 L3 Y U1 3 V1 6 W M 3~ 7 U2 12 V2 8 W2 77

78 Description Direct driven centrifugal fans / DDM / Description Safety These fans are intended to be incorporated into finished products for the treatment of clean and filtered air, free of dust, particles, shavings, grease, etc., within the rated ranges of temperature and electrical supply. The design of the installation shall guarantee the essential safety requirements, as specified by the locally enforceable legislation, including safety against human contact with moving parts, e.g. by application of the design principles stated in EN SO 121. When the inlet and/or outlet of a fan are connected to a ducting system, or to a closed plenum, including integral filters or grids, these may be designed also to provide the specified level. Otherwise, the fan must be protected by fitting appropriate inlet or outlet guards, designed in accordance with EN SO 13857, available from Nicotra Gebhardt as accessories or options. Type code 1F 3F Single phase Three phase erformance data pole 4-pole 6-pole 1V 2V 3V 4V FL SCT S SB GRG GRG 1-Speed 2-Speeds 3-Speeds Outlet flange Terminal box Special version Mounting Feet nlet guard Outlet guard 4-Speeds ir performance ratings shown in this catalogue have been derived from performance tests made with installation type "B", with free inlet and ducted outlet. The performance data shall be obtained in a laboratory registered by MC for MC 21/ air performance testing. Data are not certified by MC. Ratings are referred to the standard air density of r 1 = 1.2kg/m 3 at the fan inlet. Sound 1m n the diagrams, the -weighted housing and free inlet sound power level is given as the emission parameter for the ventilator. The -weighted noise level L p7 for a distance of 1m (see sketch) is achieved approximately in that the correction value given below is subtracted from the respective sound power level. t should be noted that site acoustics, duct design, reverberation, natural frequencies etc. can all influence noise to a greater or a lesser extent. L p7 L w7 - dl Correction values dl: Size 1/1: dl = 11dB Size 12/: dl = 13dB 1 = Fan 1.1 = Motor 2 = duct on discharge 3 = Chamber 4 = Microphone position Fan operating area db For a proper fan selection the duty point in the grey area to the left of the leftmost dashed parabolic line drawn on each performance diagram should preferably be avoided. n this area the fan stall is producing fluctuating pressure and fluctuating loads on the fan and motor; some single-phase motors may also be overheating in this low-load condition. When the performance curves of a fan are cut to the right with continuous-line parabola, a fan selection with the duty point located below of this parabola shall be carefully avoided, because the drive motor would be overloaded and would be overheating. Such an operating condition may be evidenced by a motor input current exceeding the maximum rated value

79 Description Direct driven centrifugal fans / DDM / Description Fan lifespan Media Motors Motor Speed regulation generally The high level of manufacturing technology and the use of selected materials provide a considerable fan operating lifetime. n most applications, the fan components more subjected to wear are the motor bearings. The bearings are sized to reach, using 8% of the maximum allowed current and working at an air temperature not higher than 4 C, a L 1h operating life of 2, hours. This means a 7 years fan lifetime, for fans running 8 hours a day. This range of fans are specially designed for use into air handling units (HU) and ventilation systems. The centrifugal fans are ideal for conveying clean air. The allowed air temperature comes from -2 C to +4 C. Most motors have F SO insulation but some of the smaller models have nevertheless B SO insulation. Motors could have 32; 44; 54 or 55 (closed frame) or 1; 2 (open frame). Detailed information for each fan model are provided with fan specification on the product pages. ll standard production motors are equipped with an integrated thermal overload protectors (TO), as against thermal overload. TO may be wired internally to windings and then they ll automatically stop the motor, if a overheating event occurs, and start the motor again once it is cooled down. TO may alternatively be externally wired, that means TO terminals are available to the user in the motor terminal block or terminal box. n this case, the TO terminals can be manually connected in series between power supply and motor windings or, alternatively, to an external device that switches off the mains to prevent that the motor be damaged by an overheating conditions. ll standard production motors can always be used with transformers or devices which do not modify the sinusoidal wave line to change the fan speed is always allowed. Speed regulation for fans equipped with single-phase motors Single or multiple speed available. Single phase motors are generally suitable for speed regulation by changing the input voltage with our electronic single-phase RVM speed regulators (see chapter "Options/ccessories" for further information). The speed variable types are marked with an dot in the technical data tables. The reduced voltage curves shown in the catalogue may be obtained by either using transformers or our RVM regulators. n the last case, we have commonly used a 2-wires connection for running currents up to 3 mpere max and a 3-wires connection for higher running currents. Speed regulation of multi-speed fans is obtained by connecting the mains to the correct motor terminals according to the wiring diagram supplied with each fan. Speed regulation for fans equipped with three-phase motors Single or double speed available. erformance diagrams of single speed fans usually shows only the curve referred to a 23V star 4V delta configuration. erformance diagrams of double speed fans usually shows the curves referred to a 4V star (high speed) 4V delta (low speed) configurations. The use of RVT controllers or inverter is only acceptable with special motors equipped with a reinforced insulation of the windings. n this case, these devices shall be in accordance with the requirements of EC / TS :26. 7

80 The high efficiency direct driven centrifugal fans DDMB, with brushless DC external rotor motor: The logical continuation of the successful series DDM. roduct features new brushless-dc external rotor motor new lapjointed scroll high efficiency low power consumption low sound power level high reliability High efficiency variable speed drive Energie saving concept high efficiency drive due to optimized motor design FC disabled at Stop NTC bypassed during operation General features integrated FC brownout 54 for complete drive dry contact - error signal simple usage - fan selection by D switches and GO! (no parameter setup) designed for double inlet fans external unit - no obstruction of intake - less aerodynamic losses nterface analogue MODBUS RTU Comparison of the different levels of system efficiency Brushless DC motor has a significantly higher level of drive system (motor and control) efficiency under all operating conditions. Drive system efficiency level Brushless DC-drive C-drive (frequency converter) C-drive (transformer) Speed range 8

81 rogram overview: DDMB range This kind of fans are specially conceived for use in dust-free environments, at temperatures up to +4 C, or higher on selected models. The performance data have been obtained in a laboratory registered by MC for MC 21/ air performance testing. Data are not certified by MC. Fan range DDMB mpeller size (width and diameter) up to 12 Brushless-DC external rotor motor High efficient variable speed drive External unit no obstruction of intake The variety of DDMB We have the right fan for all your applications! Many different sizes, versions and options are available in the DDMB range! ir flow up to 6, Static pressure up to 1,5 Version Description Figure DDMB Lap-jointed scroll made from galvanized steel and forward curved blades impeller directly mounted on a brushless-dc external rotor motor. EKE 7 external commutation unit +FL with discharge flange mounted +SB with housing feet either mounted or loose 81

82 DDMB-7/7 Direct driven centrifugal fans / DDMB / 225 1/min /min DDMB 7/7 M6 +EKE [G1] 23 V 5/6 Hz 81 db /min 1.5 kw e 82

83 DDMB-7/7 Direct driven centrifugal fans / DDMB / Speed Mains Mains Max. power Max. input control Curves motor power voltage hases frequency consumption current Speed DDMB 7/7 W V Hz W 1/min M6 +EKE7-65 (5) [G1] ~ 5/ Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDMB 7/7 C kg kg/m³ M6 +EKE F EXT B 6M4 (5) = Stepless speed controllable via electronical Commutation Unit The fans must be used with the Electronical Commutation Unit EKE7. ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDMB 7/7 M

84 DDMB-/7 Direct driven centrifugal fans / DDMB / 225 1/min /min 6 DDMB /7 M61 +EKE V 5/6 Hz 84 db [1] /min kw e 84

85 DDMB-/7 Direct driven centrifugal fans / DDMB / Speed Mains Mains Max. power Max. input control Curves motor power voltage hases frequency consumption current Speed DDMB /7 W V Hz W 1/min M61 +EKE7-65 (5) [1] ~ 5/ Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDMB /7 C kg kg/m³ M61 +EKE F EXT B 6M41 (5) = Stepless speed controllable via electronical Commutation Unit The fans must be used with the Electronical Commutation Unit EKE7. ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDMB /7 M

86 DDMB-/7 TGHT Direct driven centrifugal fans / DDMB / DDMB /7 TGHT M61 +EKE /min /min 86 [J1] 23 V 5/6 Hz 86 db /min kw e 86

87 DDMB-/7 TGHT Direct driven centrifugal fans / DDMB / Speed Mains Mains Max. power Max. input control Curves motor power voltage hases frequency consumption current Speed DDMB /7 TGHT W V Hz W 1/min M61 +EKE7-65 (5) [J1] ~ 5/ Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDMB /7 TGHT C kg kg/m³ M61 +EKE F EXT B 6M43 (5) = Stepless speed controllable via electronical Commutation Unit The fans must be used with the Electronical Commutation Unit EKE7. ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDMB /7 TGHT M

88 DDMB-/ Direct driven centrifugal fans / DDMB / 21 1/min 8 1 1/min 7 6 DDMB / M61 +EKE7-65 [K1] V 5/6 Hz 84 db /min kw e 88

89 DDMB-/ Direct driven centrifugal fans / DDMB / Speed Mains Mains Max. power Max. input control Curves motor power voltage hases frequency consumption current Speed DDMB / W V Hz W 1/min M61 +EKE7-65 (5) [K1] ~ 5/ Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDMB / C kg kg/m³ M61 +EKE F EXT B 6M42 (5) = Stepless speed controllable via electronical Commutation Unit The fans must be used with the Electronical Commutation Unit EKE7. ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDMB / M

90 DDMB-/ TGHT Direct driven centrifugal fans / DDMB / /min DDMB / TGHT M61 +EKE7-65 [L1] 23 V 5/6 Hz /min 83 db /min kw e

91 DDMB-/ TGHT Direct driven centrifugal fans / DDMB / Speed Mains Mains Max. power Max. input control Curves motor power voltage hases frequency consumption current Speed DDMB / TGHT W V Hz W 1/min M61 +EKE7-65 (5) [L1] ~ 5/ Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDMB / TGHT C kg kg/m³ M61 +EKE F EXT B 6M44 (5) = Stepless speed controllable via electronical Commutation Unit The fans must be used with the Electronical Commutation Unit EKE7. ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDMB / TGHT M

92 DDMB-1/8 Direct driven centrifugal fans / DDMB / 2 1/min /min DDMB 1/8 M62 +EKE V 5/6 Hz [M1] db /min kw e 2

93 DDMB-1/8 Direct driven centrifugal fans / DDMB / Speed Mains Mains Max. power Max. input control Curves motor power voltage hases frequency consumption current Speed DDMB 1/8 W V Hz W 1/min M62 +EKE7-65 (5) [M1] ~ 5/ Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDMB 1/8 C kg kg/m³ M62 +EKE F EXT B 6M45 (5) = Stepless speed controllable via electronical Commutation Unit The fans must be used with the Electronical Commutation Unit EKE7. ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDMB 1/8 M

94 DDMB-1/1 Direct driven centrifugal fans / DDMB / 2 1/min 1 DDMB 1/1 M62 +EKE V 5/6 Hz [N1] /min /min 82 db kw e 1 2 1/min DDMB 1/1 M63 +EKE V 5/6 Hz 8 [N2] db kw e 4

95 DDMB-1/1 Direct driven centrifugal fans / DDMB / Speed Mains Mains Max. power Max. input control Curves motor power voltage hases frequency consumption current Speed DDMB 1/1 W V Hz W 1/min M62 +EKE7-65 (5) [N1] ~ 5/ M63 +EKE7-65 (5) [N1] ~ 5/ Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDMB 1/1 C kg kg/m³ M62 +EKE F EXT B 6M46 M63 +EKE F EXT B 6M47 (5) = Stepless speed controllable via electronical Commutation Unit The fans must be used with the Electronical Commutation Unit EKE7. ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDMB 1/1 M DDMB 1/1 M

96 DDMB-12/ Direct driven centrifugal fans / DDMB / 18 1/min DDMB 12/ M63 +EKE V 5/6 Hz [O1] /min /min 84 db kw e 6

97 DDMB-12/ Direct driven centrifugal fans / DDMB / Speed Mains Mains Max. power Max. input control Curves motor power voltage hases frequency consumption current Speed DDMB 12/ W V Hz W 1/min M63 +EKE7-65 (5) [O1] ~ 5/ Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDMB 12/ C kg kg/m³ M63 +EKE F EXT B 6M48 (5) = Stepless speed controllable via electronical Commutation Unit The fans must be used with the Electronical Commutation Unit EKE7. ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDMB 12/ M

98 DDMB-12/12 Direct driven centrifugal fans / DDMB / /min DDMB 12/12 M63 +EKE V 5/6 Hz /min [1] /min db kw e 8

99 DDMB-12/12 Direct driven centrifugal fans / DDMB / Speed Mains Mains Max. power Max. input control Curves motor power voltage hases frequency consumption current Speed DDMB 12/12 W V Hz W 1/min M63 +EKE7-65 (5) [1] ~ 5/ Motor Motor thermal Thermal Media Temperature max. Fan weight Density of media nstallation type (SO 581) rticle number DDMB 12/12 C kg kg/m³ M63 +EKE F EXT B 6M4 (5) = Stepless speed controllable via electronical Commutation Unit The fans must be used with the Electronical Commutation Unit EKE7. ttention! We suggest to do not use the fan in the grey marked area! The noise ratings given in the performance curves are sound power level, see Technical Description. Dimensions in mm, subject to change. DDMB 12/12 M

100 DDMB Direct driven centrifugal fans / DDMB / Specifications Specifications High performance centrifugal fan DDMB Double width, double inlet (DWD), direct driven forward curved blades fan. Lap-jointed scroll of galvanized steel (EN1142) assembled through a high technology roller-lock seaming (sizes 7 inches), spot-welded scroll of galvanized steel (sizes <7 inches). Straight cut off plate at fan outlet. mpeller with forward curved blades of galvanized steel, directly mounted on a brushless DC "External rotor" motor, optimal motor cooling and no trasmission losses. High efficient brushless DC motor with external control unit no obstruction of intake; continuously variable speed control with integrated active FC and brownout, drive system complete in 54, 5/6Hz,...5V/...1V, Modbus RTU. Maintenance free, vibration isolaton pads. mpeller dynamically balanced according to SO 14. Different fan sizes, options and accessories available - see technical data. Fan data Fan type Volume flow Static pressure ir density at fan inlet r kg/m³ ir temperature Max. power consumption Speed Frequency Sound power level ( weighted) Weight t e N f L W m C kw 1/min Hz db kg Fittings / ccessories Outlet flange - O Outlet flexible connection - (sizes 7/7) Mounting feet - O/ (sizes 7/7) Terminal box - O nlet guard -O/ Outlet guard - O/ owder-coating - O Legend O = Options = ccessory O/ = The item could be delivered as an option or an accessory lease, check availability of each individual option or accessory on each specific fan model. 1

101 Electrical commutation unit Electrical commutation unit Direct driven centrifugal fans / DDMB / Electrical commutation unit Execution Controller EKE7 with single phase input and variable output voltage and frequency, especially designed to operate forward curved fans with brushless DC motors. By using modern power semiconductors a high efficiency at any speed is guaranteed. Specification suitable exclusively for operating Nicotra Gebhardt brushless DC motors for single phase supply 23V/5-6Hz input power up to 1.8kW internal speed-, power- and motor current limitation can be adjusted according to the connected fan type simply by dip switches integrated active ower Factor Correction (power factor >5%) Modbus RTU serial interface analogue interface...5v/ 1V dry error contact (max. 24V DC/25m) 54 (protected against dust and splashing water) Standards and guide lines European Low Voltage Directive The Controller EKE7 complies to the requirements of the Low Voltage Directive 26/5/EC. The unit has been manufactured according to the standard: EN (Semiconductor converters - General requirements and line commutated converters) European EMC Directive The Controller EKE7 is supplied excluively in connection with products of the company Nicotra Gebhardt. The unit is fully integrated in the corresponding products and then complies to all requirements of the EMC directive, according to the EMC product standard for electrical drives with variable speed EN European Machinery Directive The Controller EKE7 does not impinge on the application field of the Machinery Directive. nterface nterface analogue Modbus RTU Motor Hall Sensor Motor ower Mains 1~ / 23 V C 5 / 6 Hz H3 H2 H1 E W V U E N L X5 X4 X3 X2 X1 erformance Speed ower Limit Current Limit p F The exact limits depend on the fan type selected by dip switches. 11

102 Fittings / ccessories Direct driven centrifugal fans / DDMB / ccessories ccessories Flanges ll options and accessories must be specified separately. lease take the technical data and dimensions from the corresponding page of the catalogue. Made from galvanized or painted steel, to connect ducts and system components to the fan outlet side. Dimensions in mm, subject to change. 28 d f f 13 b 13 Ø d1 a 13 e e 13 c DDMB a b c d e f 7/ / /7 TGHT / / TGHT / / / / Ø d1 Flexible connection Flexible connection to connect the fan to system components or units, absorbing and stopping the vibration transmission. Dimensions in mm, subject to change d 13 f f 13 b Ø d1 a 13 e e 13 c DDMB a b c d e f 7/ / /7 TGHT / / TGHT / / / / Ø d1 Dimensions in mm, subject to change. 224 d f f 13 b 13 Ø d1 a 13 e e 13 c DDMB a b c d e f 7/ / /7 TGHT / / TGHT / / / / Ø d1 12

103 Fittings / ccessories Direct driven centrifugal fans / DDMB / ccessories Mounting feet Feet made from galvanized steel, either mounted or loose, enable the fan to be installed with a, and 27 orientation. Dimensions in mm, subject to change. w x3 w w q x4 s x2 11x16 6 v r h x1 w p l DDMB h l p q r s v w x1 x2 x3 x4 7/ / /7 TGHT / / TGHT / / / / rotection guards ncreased corrosion The fans are designed for installation in equipment and as standard are not equipped with protective guards. They should not be put into operation before all protective devices are fitted and connected! rotective measures must be carried out as set out in DN EN SO 121 "Safety of machinery - Basic concepts, general principles for design". f the application of the fan allows free access to the inlet and discharge apertures, safety devices must be put in place on the fan in accordance with DN EN SO 13857! Suitable safety guards are available as an optional extra. Nicotra Gebhardt fans are provided as a standard equipment with a highly efficient corrosion but, in the event of extremely high corrosion risk, additional corrosion s might be required. Following to the application and corrosion stress conditions, special coatings of various types and thickness can be supplied on request. 13

104 Fittings / ccessories Direct driven centrifugal fans / DDMB / ccessories Speed regulator module REGOT REGOT1 and REGOT2 are devices used to give variable voltage by inside rotating. t s possible regulate minimun voltage. STO function is implemented. REGOT seriers are used to control voltage controlled electronic devices (DRVER, Electronic motor, brushless inverter). Dimensions in mm, subject to change Regulation Minimum 1 15 Wiring Diagram REGOT1 without STO Minimun Regulation V N V+ with STO Minimun Regulation N V V+ Wiring Diagram REGOT2 without STO Minimun Regulation V N V+ with STO Minimun Regulation N V V+ 14

105 Description Direct driven centrifugal fans / DDMB / Description Safety These fans are intended to be incorporated into finished products for the treatment of clean and filtered air, free of dust, particles, shavings, grease, etc., within the rated ranges of temperature and electrical supply. The design of the installation shall guarantee the essential safety requirements, as specified by the locally enforceable legislation, including safety against human contact with moving parts, e.g. by application of the design principles stated in EN SO 121. When the inlet and/or outlet of a fan are connected to a ducting system, or to a closed plenum, including integral filters or grids, these may be designed also to provide the specified level. Otherwise, the fan must be protected by fitting appropriate inlet or outlet guards, designed in accordance with EN SO 13857, available from Nicotra Gebhardt as accessories or options. Type code 1F 3F Single phase Three phase erformance data pole 4-pole 6-pole 1V 2V 3V 4V FL SCT S SB GRG GRG 1-Speed 2-Speeds 3-Speeds Outlet flange Terminal box Special version Mounting Feet nlet guard Outlet guard 4-Speeds ir performance ratings shown in this catalogue have been derived from performance tests made with installation type "B", with free inlet and ducted outlet. The performance data shall be obtained in a laboratory registered by MC for MC 21/ air performance testing. Data are not certified by MC. Ratings are referred to the standard air density of r 1 = 1.2kg/m 3 at the fan inlet. Sound 1m n the diagrams, the -weighted housing and free inlet sound power level is given as the emission parameter for the ventilator. The -weighted noise level L p7 for a distance of 1m (see sketch) is achieved approximately in that the correction value given below is subtracted from the respective sound power level. t should be noted that site acoustics, duct design, reverberation, natural frequencies etc. can all influence noise to a greater or a lesser extent. L p7 L w7 - dl Correction values dl: Size 1/1: dl = 11dB Size 12/: dl = 13dB 1 = Fan 1.1 = Motor 2 = duct on discharge 3 = Chamber 4 = Microphone position Motors Motor Speed regulation These brushless DC external rotor motors (BLDC) are especially designed. They have an highest efficiency also in the partial load area. The motors are protected via safe operating area (SO). SO defines the conditions (voltage, power, current, speed) over which the drive can be expected to operate without self-damage. The SO of the DDMB is automatically guaranteed by the motor design and the controller settings. dditionally to that the motors are equipped with thermo contact (TO) to protect the motors against thermal overload. The speed limits are defined by the presetting of the dip switches and the winding configuration. Between that limits the speed can be controlled via analogue (...5V or...1v) or MODBUS-interface. 15

106 Description Direct driven centrifugal fans / DDMB / Description Fan operating area db For a proper fan selection the duty point in the grey area to the left of the leftmost dashed parabolic line drawn on each performance diagram should preferably be avoided. n this area the fan stall is producing fluctuating pressure and fluctuating loads on the fan and motor; some motors may also be overheating in this low-load condition. When the performance curves of a fan are cut to the right with continuous-line parabola, a fan selection with the duty point located below of this parabola shall be carefully avoided, because the drive motor would be overloaded and would be overheating. Such an operating condition may be evidenced by a motor input current exceeding the maximum rated value Fan lifespan Media The high level of manufacturing technology and the use of selected materials provide a considerable fan operating lifetime. Only the motor bearings are subject to wear in most applications. The calculated bearing life time L1h is appr. 3, hrs. This range of fans are specially designed for use into air handling units (HU) and ventilation systems. The centrifugal fans are ideal for conveying clean air. The allowed air temperature comes from -2 C to +4 C. 16

107 ccessories Direct driven centrifugal fans / ppendix / ccessories Frequency converter Design Frequency inverter with variable output voltage and frequency, specially designed for the operation of centrifugal fans with induption motors. Due to the use of modern power semiconductors it is possible to achieve a speed of revolution with high efficiency. Switching frequencies up to 16kHz can be set with all types. f the highest switching frequencies are required (for example for reasons of noise reduction), the maximum output current is decreased, in which case the performance category should be specially checked. The overall package includes the frequency inverter, filter for B (for residential and commercial uses) as well as a control unit. General erformance characteristics Motor feature for motors with thermistor temperature sensors, adjustable accelaration and deaccelaration ramps, minimum and maximum rotation speeds, fixed rotation speeds, trapping switch during operation, programmable inputs and -controller (MM42 and MM43 only), RS485 serial interface as well as a detailed operating instructions. Caution about combination with isolators (ESH)! Special EMCaction can be necessary, furthermore do not switch during operation, overvoltages can destroy the switch and the motor-winding. erformance range G11 1C 23V (for single-phase C supply).25kw to 2.2kW rated motor power, 2V to 24V 1% single-phase C, 47Hz up to 63Hz, three-phase current output 3 23V C, 2. ermitted ambient temperature during operation: -1 C up to +4 C. erformance range MM42 3C 4V (for three-phase C supply).55kw to 11kW rated motor power, 38V to 48V 1% three-phase C, 47Hz up to 63Hz, three-phase current output 3 4V C, 2. ermitted ambient temperature during operation: -1 C up to +5 C. The interference suppression filter required to comply with the EMC basic interference suppression standard EN (residential and commercial uses) is integrated into the package as substructure option. ower choke to comply with EN as additional component. Observe performance reduction when using high clock frequencies! erformance range MM43 3C 4V (for three-phase C supply) 15kW to 25kW rated motor power, 38V to 48V 1% three-phase C, 47Hz up to 63Hz, three-phase current output 3 4V C, 2. ermitted ambient temperature during operation: -1 C up to +5 C. The interference suppression filter required to comply with the EMC basic interference suppression standard EN (industrial applications) is partially integrated. n order to attain EMC requirements Class B a frequency inverter without filter should be selected. The appropriate EMC-B filter is then required as an additional component. Observe performance reduction when using high clock frequencies! The indicated ratings of the units are made for a quick selection. The exact dedication of an inverter in this catalogue is made by taking into account of the max. admitted current at a pulse frequency of 4kHz. t is important to know that at higher pulse frequencies the supplied current of the inverter will be decreasing, with the possible consequences of having to select a larger inverter unit. lso longer feed lines or additional radio frequency filters may lead to the choice of a larger inverter size. The selected frequency inverters (G11 und MM42) are units contains the frequency inverter (as shown in the following tables) with the matching interference suspression filter (Class B) and a control panel. further component is the line choke which is available as an accessorie. For more information the available frequency inverters are shown in the following tables. 422

108 ccessories Direct driven centrifugal fans / ppendix / ccessories Frequency converter Dimensions For three-phase C motors on the single-phase supply. b a c 6SL3211- power current a b c Weight kw mm mm mm kg B12-5B B13-7B B15-5B B17-5B B B B Dimensions For three-phase C motors on the three-phase supply b a c 6SE642- power current a b c Weight kw mm mm mm kg 2UD UD UD UD D22-2B D23-B D24-B D25-5C D27-5C D31-1C Dimensions For three-phase C motors on the three-phase supply b a c 6SE643- power current a b c Weight kw mm mm mm kg 2D31-5C D31-8D D32-2D D33-D D33-7E D34-5E D35-5F D37-5F D37-8F UD41-1F UD41-3F UD41-6G UD42-G UD42-5G

109 Direct driven centrifugal fans / ppendix / ccessories Motor unit Motor unit for three-phase current motors (standard motors) without thermal contacts. Design lastic casing in 55, permissible ambient temperature +4 C, 4Hz up to 6Hz, frontal operation, for wall mounting. Motor unit for singlespeed, non-variable speed three-phase current motors without thermal contacts. Motor unit EUM 33 Function The motor units must be adjusted on site to the trigger current. f the preset trigger current is exceeded, the device disconnects the motor from the mains supply via a thermal overload release. ressing the on key causes the unit to turn on again. ll motor units EUM33 are also suitable for the of EExe-motors (TB-rüfung Gesch-Nr. 3.35/386.36). They must however be mounted outside of explosion endangered areas, since they are not themselves designed with explosion. EUM 33- Continuous current Setting range Max. nominal power kw 4-8D.4 +.2/ D.6 +.4/ D 1 +.6/ D / D / D / D 6 +4/ D 1 +6/ D 16 +1/ D 2 +16/ D 25 +2/ D 5 +25/ D 58 +5/+58 3 Dimensions in mm, subject to change Wiring Diagram L1 L2 L3 E EUM U1 V1 W1 424

110 ccessories Direct driven centrifugal fans / ppendix / ccessories Universal control device Universal control device for installation in control cabinets Digital control module for controlling pressure, air velocity or volume flow ( controller). For example, a transformer for fans is controlled via the...1v output. The device is designed for installation in control cabinets. Type Multi functional LC-display for actual and nominal values (m/s, h = mbar, 1). Menuassisted adjustment via three function keys. ctual value input...1v e. g. for: air speed sensors Type EL in measuring ranges from...1m/s and...1m/s e. g. for ir velocity control in clean room technology ressure sensors Type E in measurement ranges 5 up to 4 e. g. for ressure control in canal systems of air conditioning systems (VVS) and Flow control in centrifugal fans with pressure tappings in the inlet cone The control module calculates the required flow () from the differential measured pressure between the surrounding level and inlet cone. Output...1V e. g. for controlling a transformer Failure message is output via display (internal/external) and relay programmable External set value specification via potentiometer or...1v signal Specification of two set values (day/night), can be switched over externally or via keyboard rotection against unauthorised setting by keyboard code pplication area ressure regulation for centralised ventilation systems and variable volume flow systems for building air conditioning (VVS) e.g. in combination with a frequency inverter or a commutation unit or a transformer and a pressure sensor Volume flow regulation for centrifugal fans (with measuring stub in the inlet cone) e.g. in combination with a frequency inverter or a commutation unit or a transformer or a mini-interface inverter and a pressure sensor and the volume flow volumeter ir speed regulation for clean room systems, e.g. in combination with a transformer and an air speed sensor Electrical connection and installation Connection to 23V, 5/6Hz. The control module can be installed in a control cabinet door. dmissible relative humidity: 85%, noncondensing. ower supply for the sensors included: +24V, 2%, max = 7m. Setting options Set values in the measurement range of the sensor (m/s, h = mbar), or in the volume flow range of the fan ( 1) Switch over of set value (day/night) Min./max. setting range Translation of performance curve ( component) Constant of integration can be selected ( component) Reversal of the effect of the control behaviour Rotation of the performance curve Switchover or programming of internal/external set value Sensor selection via keypad rogramming for Filter fault Keypad code K factor entry (The K1-factor can be found in the current lists of our fan line) Max. output current Motor Operating consumption ER 2- nput voltage Output voltage V V m V C 4-5E /1 / /+4 Operating temperatur 425

111 ccessories Direct driven centrifugal fans / ppendix / ccessories Universal control device Dimensions in mm, subject to change max nstrument panel window Wiring Diagram (+) ( ) D+ 24V 24V D2 1 GND L1 N E D GND D1 D3 2 GND E2 E Mains K1 K2 DT B GND RS485 Out, 24 V DC nput, Digital 1/2/3 Out, nalog 1/2 + 2 Out -1 V nput, nalog -1 V 1/2 E1 + E2 nput -1 V + 1 E1 + Out nput -1 V -1 V E2 C V m C V m Contact rating max. 5 / 25 V C 426

112 Direct driven centrifugal fans / ppendix / ccessories Differential pressure sensor Differential pressure sensor with membrane for measuring the pressure, negative pressure or differential pressure of nonaggressive gases. Type The differential pressure to be measured acts transformed into an output signal of...1v by electronics (in SMD technology). pplication ranges Volume flow regulators in centrifugal fans (with volume flow measuring device MV) in connection with a frequency inverter type G11, MM42, MM43, or a universal regulator appliance type ER 2-4-5E in connection with a frequency regulator. Electrical connection and installation The differential pressure sensor delivers a starting signal (...1V) by pressure increase at the lus connection opposite pressure on the Minus connection. Voltage supply V DC or 24V C, 15% ressure connections must point downward, tube connection ø5mm Measuring accuracy Null drift:.% Sum of linearity and hysteresis: 1% Temperature drift zero point:.3%/1k Temperature drift length of measurement:.2%/1k Dimensions in mm, subject to change ~ ø5 Motor E 1- ressure range Max. current consumption Overload Output signal proportional m V C / /+1 +/ / /+1 +/ / /+1 +/ / /+1 +/ / /+1 +/+5 Operating temperatur Wiring Diagram ressure connections 5 mm + p - p ower supply V DC 24 V C ±1 % brown + ~ yellow + Output...1V DC = white ~ 427

113 ccessories Direct driven centrifugal fans / ppendix / ccessories solator ESH 21 solator ESH 21 ( 3kW) solator ESH 21 ( 5.5kW) Design Beautifully shaped, shock-resistant plastic casing. rotection 44/65, for sur-face mounting, switching symbols and. The isolator is fitted with connection terminals that are very accessible and has a con-nection diagram glued in the casing. The ESH21 up to 3kW is designed to 44. t is equipped with an integrated lo-cking mechanism. The ESH21 up to 5.5kW is designed to 65. t is equipped with a coupling cover and an integrated locking mechanism. padlock can in some cases be fitted to the rotary switch. Function The isolator disconnects the fan safely from the mains in the event of cleaning, maintenance or repair work on site and thus avoids accidents due to uncontrolled activation of the unit by third parties. t is no main switch or emergency switch. ll of the ified isolators are fitted with potential-free contacts (1 closer and 1 opener). The isolators for motors with a built-in thermal contact have on principle three supplementary auxiliary contacts, so that the pre-switched control device does not drop out during cleaning or servicing work due to motor. Caution about combination with frequency inverter! Special EMC-action can be necessary, furthermore do not switch during operation, overvoltages can destroy the switch and the motor-winding. The isolators are grouped according to motor rated power. ll important characteristic data are evident from the model designation. E.g.: ESH = 3kW switch - 6 main contacts - 5 auxiliary contacts Dimensions a a b b d ESH 21 3 kw d ESH kw c c ESH 21- ermissible motor power a b c d kw mm mm mm

114 ccessories Direct driven centrifugal fans / ppendix / ccessories solator ESH 22 Design Shock-resistant metal casing, black switch with symbols and. rotection 65 or 54, for surface mounting (see determination in the tabular). The isolator is fitted with connection terminals that are very accessible and has a connection diagram glued in the casing. ll isolators are equipped with a coupling cover and an integrated locking mechanism. n some cases a padlock can be fitted to the rotary switch. Dimensions a b d c Function The isolator disconnects the fan safely from the mains in the event of cleaning, maintenance or repair work on site and thus avoids accidents due to uncontrolled activation of the unit by third parties. t is no main switch or emergency switch. ll of the ified isolators are fitted with potential-free contacts (1 closer and 1 opener). The isolators for motors with a built-in thermal contact have on principle three supplementary auxiliary contacts,so that the preswitched control device does not drop out during cleaning or servicing work due to motor. Use The isolator ESH22 with metal casing is necessary, if screened components must be used. (e.g. frequency inverters or control engineering devices are used featuring electronic components). ttention! Do not switch during operation, overvoltages can destroy the switch and the motor winding! The isolators are grouped according to motor rated power. ll important characteristic data are evident from the model designation. E.g.: ESH = 7.5kW switch, 6 main contacts, 5 auxiliary contacts. ESH 22- kw mm mm mm mm G21 2 G G21 2 G G21 2 G G21 2 G G2/1 G16 2 G G36/1 G16 2 G G2/1 G16 2 G G36/1 G16 2 G G36/1 G16 2 G G36/1 G16 2 G G36/1 G16 2 G G36/1 G16 2 G G21 2 G G16 2 G G16 2 G16 ermissible motor power a b c d Cable lead-through (top) Cable leadthrough (bottom) 42

115 Notes Direct driven centrifugal fans / ppendix / Notes Quality management system Machine Safety Catalogue data DN EN SO 1 Nicotra Gebhardt quality is the result of a continuous company policy intended to guarantee that our product properties and features are clearly superior to comparable products. This already established company maxim led in pril 185 to the auditing and certification of the existing quality management system. n the following years it was updated to match the changing international and European standards. Modern production processes, monitored by our quality management system, guarantee a high repeat accuracy in production. This ongoing high standard of quality permits the establishing of the performance data in es of accuracy in accordance with DN The narrow tolerances ensure a high level of data reliability for our products. The fans contained in this catalogue are not machines in the sense of the EC Machine Directive. They are delivered with a manufacturer "Declaration of incorporation". The assessment of the dangers associated with the fan and necessary safety measures are based on the VDM Unit sheet : Fans; Safety requirements. The operating instructions give which safety measures are still necessary on assembly to ensure that the fans comply with the Machine Directive 26/42/EC. We reserve the right to change any measurements and technical data in this catalogue in accordance with further development of our products. ll information valid at the time of printing. 43

116 17

117 Nicotra Gebhardt worldwide SN Ctra. lcalá-villar del Olmo, Km. 2, Villalbilla-Madrid hone Fax c/.coso, 67-, esc. 1.a,1.oB 51 Zaragoza hone Fax EN-TD3-CFD DF BELGUM Haeghensgoed, 13 - /1 27 Laarne hone +32 () Fax +32 () [email protected] FRNCE Leader's rk Bat 1 3 chemin des Cytises 34 Francheville hone +33 () Fax +33 () [email protected] SWEDEN Box 237 Kraketorpsgatan Mölndal hone Fax [email protected] GRET BRTN Unit D, Rail Mill Way rkgate Business rk Rotherham South Yorkshire S62 6JQ hone Fax [email protected] UNTED STTES O BOX 21 Sandy, Utah 84 hone 1(81) Fax 1(81) Mobile 1(81) [email protected] MLYS Lot 17, Jalan Balakong Taman erindustrian Bukit Belimbing 433 Seri Kembangan Selangor hone Fax [email protected] THLND 6/2 Soi Suksawadi 2, Moo 4, Suksawadi Road, Kwang Jomthong, Khet Jomthong, Bangkok 115 hone Fax [email protected] SNGORE 3, Science rk Drive, # 4-7, The Franklin Singapore Science rk 1 Singapore hone Fax [email protected] USTRL 65 Yale Drive, Epping, VC 376 hone Fax [email protected] ND lot no 28F & 2, Sector-31,Kasna, Greater Noida U. (ndia) hone hone (Mumbai) hone (Bangalore) [email protected] CHN 88 Tai n Road, XinQiao, ShiJi, nyu Guangzhou R CHN hone +86 () Fax +86 () [email protected] Nicotra Gebhardt Germany Nicotra Gebhardt taly 1 Nicotra Gebhardt GmbH Gebhardtstraße Waldenburg Germany hone +4 () Fax +4 () [email protected] Nicotra Gebhardt S.p. Via Modena, Zingonia (BG) taly hone Fax [email protected] nicotra-gebhardt.com

ICQ Series - square centrifugal

ICQ Series - square centrifugal product ICQ Square Centrifugal (TEFC) dimensions mm 280-710 poles & duty 4-8 / up to 4,500 L/s application High performance centrifugal fans for medium to high pressure ducted systems. ICQ Series The ICQ

More information

FAN & BLOWER CENTRIFUGAL FANS

FAN & BLOWER CENTRIFUGAL FANS FAN & BLOWR CNTRIFUGAL FANS INTRODUCTION GNRAL PRODUCT RANG FANS BY FANTCH - INTRACTIV PRODUCT SUIT SLCTION PROGRAM PRFORMANC CONSTRUCTION The Fan & Blower range of centrifugal fans is marketed to the

More information

Energy Saving ECM Motors and Fans. 2010 Ventilation Catalogue

Energy Saving ECM Motors and Fans. 2010 Ventilation Catalogue Energy Saving ECM s and Fans 2010 Ventilation Catalogue CONTENTS For ellington, sustainability is about delivering products at competitive prices while preserving the environment for future generations.

More information

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of

More information

TFSR & TFSK Roof Fans

TFSR & TFSK Roof Fans Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans TFSR & TFSK Roof Fans With swing-out function 2 I TFSR/TFSK TFSR & TFSK Roof

More information

EC medium pressure axial fans. The effi cient system solution.

EC medium pressure axial fans. The effi cient system solution. EC medium pressure axial fans. The effi cient system solution. GreenTech EC technology in a new dimension. Thanks to the new axial fans, our highly effi cient GreenTech EC technology is now available for

More information

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC Technical Concept Filter Fan Unit SILENT Type SILENT AC Type SILENT EC Filter Fan Unit SILENT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide clean

More information

Surface Technology. Centrifugal Fan GMD

Surface Technology. Centrifugal Fan GMD Centrifugal Fan ATEX classed adapted for paint shops Wide assortment broad area of application Service friendly low maintenance costs Headquarters: Centrifugal Fan Centrifugal Fan is a direct driven industrial

More information

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide

More information

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to: OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND

More information

Transformer oil cooler ALFA A02

Transformer oil cooler ALFA A02 A02 Transformer oil cooler ALFA Transformer oil cooler ALFA The transformer oil cooler ALFA is used to cool power transformers by means of forced air and oil flow. The oil in the cooler is circulated using

More information

Heating, air-conditioning, cooling

Heating, air-conditioning, cooling Series description Design High efficiency, single stage, low pressure, inline centrifugal pump Supplied with EC motor and electronic duty adaptation Available in glanded construction, mechanical shaft

More information

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design Ideal installation for; Offices Branch Offices Schools Computer Aided Classes Government Offices Hotels

More information

CADB and CADT-D / DI / DC Series

CADB and CADT-D / DI / DC Series HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised

More information

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages.

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F400-120. advantages. Défumair XR smoke-extraction fan extraction casing for kitchen at F400-120 Personalisation : - Phonic insulation version by insulated double-skin panels through 25 mm glass wool, class M1. advantages Originally

More information

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

O-I DUBI PLANT FANS Quotation Spec Data & Specifications TECHNICAL DATA O-I DUBI PLANT FANS Quotation Spec Data & Specifications 1 page for the global informations + 12 pages for the fans data Revision 2 end april Global informations: These fans are a replacement

More information

Specifying a Variable Frequency Drive s

Specifying a Variable Frequency Drive s Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

Manual motor starter MS116

Manual motor starter MS116 Data sheet Manual motor starter MS116 Manual motor starters are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/ OFF control, and

More information

SERVER ROOM CABINET INSTALLATION CONCEPTS

SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS SERVER ROOM CABINET INSTALLATION CONCEPTS ZPAS 169 EXAMPLES OF SERVER ROOMS PROJECTS WITH ZPAS CABINETS Data Box in the

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

Cooking at the Speed of light!

Cooking at the Speed of light! Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide

More information

WIND TURBINE TECHNOLOGY

WIND TURBINE TECHNOLOGY Module 2.2-2 WIND TURBINE TECHNOLOGY Electrical System Gerhard J. Gerdes Workshop on Renewable Energies November 14-25, 2005 Nadi, Republic of the Fiji Islands Contents Module 2.2 Types of generator systems

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

Quick Connect. quick - simple - efficient. www.g-mw.de

Quick Connect. quick - simple - efficient. www.g-mw.de Quick Connect quick - simple - efficient www.g-mw.de Phone: +49 9103 7129-0 Fax: +49 9103 7129-207 Innovative connection technology to plug three single-phase current transformers to multifunctional power

More information

SUNON SPECIFICATION FOR APPROVAL

SUNON SPECIFICATION FOR APPROVAL SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X25 mm M O D E L : KDE2406PTB2 APPROVED NO : APPROVED BY : (AUTHORZIED) SPEC.NO D600732 ISSUE DATE 10.01.1998 DAWN.

More information

Electric Rotary Actuator - On/Off or programmable control actuator

Electric Rotary Actuator - On/Off or programmable control actuator Electric Rotary Actuator - On/Off or programmable control actuator Direct mounting on quarter-turn valves Manual override standard Corrosion resistant Adjustable limit switches Multi-voltage version Type

More information

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ

CRN32-2-2 A-F-G-E-HQQE 3x400D 50 HZ GRUNDFOS DATA BOOKLET CRN32-2-2 A-F-G-E-HQQE 3x4D 5 HZ Grundfos Pump 96122352 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn32/96122352/crn-32-2-2-a-f-g-e-hqqe.html

More information

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features RKE Heat recovery unit from 200 to 6800 m 3 /h General features RKE heat recovery units are suitable for residential and commercial applications and offer a real energy saving in forced ventilation plants,

More information

Conlift1, Conlift2, Conlift2 ph+

Conlift1, Conlift2, Conlift2 ph+ GRUNDFOS DATA BOOKLET Conlift1, Conlift2, Conlift2 ph+ Small lifting stations 50 Hz CONLIFT1, CONLIFT2, CONLIFT2 ph+ Table of contents 1. Product overview 3 Conlift for condensate applications 3 Applications

More information

8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!

8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient! Bathroom and toilet extract fans SILENT-100 BATHROOM EXTRACT FANS SILENT-100 Series SILVER versions The SILENT-100 CZ and CRZ can be supplied Range of axial extractors with airflow rates of approx. 95

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

Photovoltaic Solar Energy Unit EESFB

Photovoltaic Solar Energy Unit EESFB Technical Teaching Equipment Photovoltaic Solar Energy Unit EESFB Products Products range Units 5.-Energy Electronic console PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION Worlddidac Member ISO 9000: Quality

More information

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled

More information

MODEL HSR-007 Direct Drive Rolling Steel

MODEL HSR-007 Direct Drive Rolling Steel MODEL HSR-007 Direct Drive Rolling Steel 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8 Tel: 866-792-9968 or 705-792-9968 Fax: 705-735-9564 www.tnrdoors.com email: [email protected] Model HSR-007

More information

Horizontal Jet Pumps 1/3-1-1/2 HP

Horizontal Jet Pumps 1/3-1-1/2 HP Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 - DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401 CONTENTS Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE 70 204 PERFORMANCE CURVE 90 205 PERFORMANCE CURVE 120 206 PERFORMANCE CURVE 200 207 - CONSTRUCTIONS

More information

Single-Phase AC Synchronous Generator

Single-Phase AC Synchronous Generator ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description

More information

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes Precision Cooling for Business-Critical Continuity Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes We re Emerson Network Power, backed by Emerson,

More information

The CLIPPER Solutions

The CLIPPER Solutions The CLIPPER Solutions 111 112 C51 6,5 Hp Ø 350mm 76kg Compact, robust and highly manoeuvrable machines designed for both wet and dry cutting of concrete and asphalt. Machine delivered without diamond blade.

More information

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0. Receiver AC-RX2/CS RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. Pin-out 38.1 3 Component Side 1 2 3 7 11 13 14 15

More information

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact The CT-AHD.12 is an electronic time relay with OFF-delay. It is from the CT-D range. With their MDRC profile and a width of only

More information

Rittal TopTherm fan-and-filter unit

Rittal TopTherm fan-and-filter unit Rittal TopTherm fan-and-filter unit System Climate Control More pressure. Higher air flow rates. 2 Assembly without tools Straightforward assembly, exchange and maintenance with no need for tools of any

More information

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans IN-LINE MIXED LOW DUT ANS ultra-quiet Series (16 to 1 models) Low profile Mixed-flow fans with sound-absorbent insulation. Extremely quiet. ertified of Approval Noise Abatement Society (TD-35, TD-5, TD-8

More information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated. Ordering information Type: DILM115(RAC240) Article No.: 239548 Sales text Contactor,55kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current Screw terminals 3 pole AC

More information

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C COOLS conditioned server - racks for direct installation into the room COOLSIDE box INVERTER R410A E C 2 COOLSIDE box GENERAL FEATURES COOLSIDE BOX is a split system consisting of an outdoor motocondensing

More information

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

How To Use A Ds340 (Dsp)

How To Use A Ds340 (Dsp) Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions

More information

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2 SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2 APPROVED NO : APPROVED BY : (AUTHORIZED) SPEC.NO D600023 ISSUE DATE 08.06.1998 DAWN.

More information

C Standard AC Motors

C Standard AC Motors C Standard AC Standard AC C-1 Overview, Product Series... C-2 Constant... C-9 C-21 C-113 Reversible C-147 Overview, Product Series Constant Reversible Electromagnetic Brake C-155 Electromagnetic Brake

More information

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power: PHOTOVOLTAIC (PV) solar panels Electricity - CE & ISO 9000 certified Photovoltaic solar panels convert sunlight into useful electricity. ZEDfabric supplies high quality mono-crystalline silicon cell PV

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw ,QGXVWULDO#*HQHUDWRU 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw Generator set consisting of engine and alternator mounted

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

RX-AM4SF Receiver. Pin-out. Connections

RX-AM4SF Receiver. Pin-out. Connections RX-AM4SF Receiver The super-heterodyne receiver RX-AM4SF can provide a RSSI output indicating the amplitude of the received signal: this output can be used to create a field-strength meter capable to indicate

More information

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)

UR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm) UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery

More information

We will discuss common industrial applications with guides for the proper use of electric motors on these.

We will discuss common industrial applications with guides for the proper use of electric motors on these. INTRODUCTION: Baldor Electric Company has prepared this Specifiers Guide to help you cover all the bases when you are specifying electric motors. It will cover in a generic way most of the subjects which

More information

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw 4 937 DESIO Current valve for AC 24 V pulse/pause control of electrical loads up to 30 kw SEA45.1 Use The current valve is used for the control of electric heating elements in heating, ventilation and

More information

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product.

Once you know the volume of air and the static pressure of the system to be cooled, you can determine the fan specifications for your product. COOLING FAN REQUIREMENTS CALCULATIONS Determining System Impedance Determining the actual airflow produced by a fan mounted in an enclosure is much more difficult than calculating the airflow required.

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

Diesel Generating Set

Diesel Generating Set MODEL Standby Power(50Hz) Prime Power(50Hz) 44KW /55KVA 40KW /50KVA Standard Features General Features: Engine( DCEC Cummins 4BTA3.9 -G) Radiator 40 O C max,fans are driven by belt, with safety guard 24V

More information

Under sill units. Type FSL-B-ZAS

Under sill units. Type FSL-B-ZAS .1 X X testregistrierung Under sill units Type, heat recovery Centrifugal fan Adaptive heat recovery damper HYGIENISCH GETESTET V DI 022 Tested to VDI 022 Secondary air unit for supply air and extract

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw ,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted

More information

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6 - B 1 Product Detail Engineering Data... B2 Structural Support... B6 Engineering Specifications... B9 - B 2 Engineering Data REMARK: Do not use for construction. Refer to factory certified dimensions &

More information

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data. 425 CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE General purpose single phase thyristors and solid state relays Product data abc 425 EUROCUBE A complete range of low cost solid state relays and

More information

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts Lo w p r o f i l e small air handlers and extract fan units Duties to 0.55m 3 /sec Available with the Electroline fitted control panel Ceiling void friendly - unit heights from 190mm to 350mm Airline VES

More information

PM734F - Technical Data Sheet Winding 28

PM734F - Technical Data Sheet Winding 28 - Technical Data Sheet Winding 28 SPECIFICATIONS & OPTIONS STANDARDS STAMFORD AC generators are designed to meet the performance requirements of IEC EN 60034-1. Other international standards, including

More information

UDSA - UDSBD unit heater

UDSA - UDSBD unit heater APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the

More information

PSR The compact range Description

PSR The compact range Description Description The PSR range is the most compact of all the ABB softstarter ranges, thereby making it possible to fit many devices into the same enclosure. The system concept with Manual Motor Starters provides

More information

RFHD. ROOF CENTRIFUGAL FANS WITH ATEX CERTIFICATION CEE ExII2G Ex d. According EU Regulation

RFHD. ROOF CENTRIFUGAL FANS WITH ATEX CERTIFICATION CEE ExII2G Ex d. According EU Regulation RFHD ROOF CENTRIFUGAL FANS WITH ATEX CERTIFICATION CEE ExII2G Ex d According EU Regulation free RFHD Centrifugal roof fans with horizontal outlet and ATEX Ex d certification Centrifugal roof fans with

More information

squrboxbox heat recovery squrboxbox I technical information

squrboxbox heat recovery squrboxbox I technical information heatrecoveryrange heat recovery squrboxbox I technical information squrboxbox Low depth high performance Only 350mm deep & up to 430l/s, providing the most effective low depth solution. Quietest solution

More information

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw DLW 8 POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw Generator set consisting of engine and alternator mounted on a fabricated steel

More information

Fan Basics and Selection Criteria (How to Use)

Fan Basics and Selection Criteria (How to Use) Feature: Understanding SANYO DENKI Products from Scratch Fan Basics and Selection Criteria (How to Use) Honami Osawa 1. Introduction In recent years, the importance of cooling technology has become even

More information

Series description: Wilo-Drain TC 40

Series description: Wilo-Drain TC 40 Series description: Wilo-Drain TC 40 H[m] Wilo-Drain TC 40 10 8 6 4 2 TC 40/8 TC 40/10 0 0 2 4 6 8 10 12 14 Q[m³/h] Design Submersible sewage pump Application Pumping heavily contaminated fluids for House/site

More information

Technical Specification for Model RSK2503 (Z)-06A IR Belt Solar Cell Firing Furnace

Technical Specification for Model RSK2503 (Z)-06A IR Belt Solar Cell Firing Furnace Technical Specification for Model RSK2503 (Z)-06A IR Belt Solar Cell Firing Furnace TECHNICAL SPECIFICATION Model RSK 2503(Z)-06A IR Belt Solar Cell Firing Furnace Temperature Range 1. Max Temperature.

More information

"AC2EC" - Replacement made easy New EC motor design Compact and efficient

AC2EC - Replacement made easy New EC motor design Compact and efficient "AC2EC" - Replacement made easy New EC motor design Compact and efficient The efficiency of the fans used is a central issue in ventilation and airconditioning technology. This is encouraged not only by

More information

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series

8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series SILENT-1 Series Range of axial extractors with airflow rates of 85 m 3 /h, for connection to 1 mm diameter circular ducting. Motor mounted on silent-elastic-blocks which absorb the vibrations and allow

More information

TIG INVERTER INSTRUCTION MANUAL

TIG INVERTER INSTRUCTION MANUAL TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4

More information

Modular Access Floor for Data Center. From Rack to Row to Room to Building

Modular Access Floor for Data Center. From Rack to Row to Room to Building Modular Access Floor for Data Center From Rack to Row to Room to Building Why using Scneider Electric modular access floor in Data Centers The evolution of modern Data Centers emphasizes specific exigencies

More information

THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS AL SERIES

THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS AL SERIES THREE-PHASE SQUIRREL CAGE ASYNCHRONOUS MOTORS AL SERIES IE2 FRAMES 80 355 0,75 315kW (1500rpm) FOR INVERTER DUTY Code Declaration of conformity The motors described in this catalogue satisfy the essential

More information

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ GRUNDFOS DATA BOOKLET CRN5-5 A-FGJ-G-E-HQQE 3x23/4 5HZ Grundfos Pump 96517184 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crn5/96517184/crn-5-5-a-fgj-g-e-hqqe.html

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512 RECEIVING 1. Check

More information

KONRAD. Hybrid Fancoil Series

KONRAD. Hybrid Fancoil Series KONRAD Hybrid Fancoil Series Konrad is an innovative radiator which cools you down and warms you up. Indeed, it cools in summer and heats in winter; but it makes it with an incomparable quietness. Thanks

More information

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

KTZ32.2-51. data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet KTZ32.2-5 data sheet parts list exploded view dimensional drawing sectional drawing performance curve parts list as Excel-spreadsheet Heltorfer Str.6 40472 Düsseldorf Germany Tel.: +49-2-479373 Fax: +49-2-479429

More information

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS 2CP Twin-impeller pumps PERFORMANCE RANGE Flow rate up to 40 l/min (27 m³/h) Head up to 112 m APPLICATION LIMITS Manometric suction lift up to 7 m Liquid temperature between -10 C and +90 C Ambient temperature

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009 Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal

More information

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range Type series booklet 8521.15/2--10 ACTELEC 31 to 800 (BERNARD) 1/4 turn electric actuators (irreversible reducer with multi -turn electric actuator ACTELEC 31: screw -nut kinematics ACTELEC 200 to 800:

More information

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single

More information

How To Build A T7 Rack For Information Technology

How To Build A T7 Rack For Information Technology THE NEXT GENERATION RACK FOR INFORMATION TECHNOLOGY THE RACK CABINET FOR INFORMATION TECHNOLOGY T7, THE HI-TECH HEART OF THE BLADESHELTER SYSTEM The real answer to the requirements of: Safety Versatility

More information

FULL DC INVERTER SYSTEMS

FULL DC INVERTER SYSTEMS FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

TRIMMING UNIT/DIAMOND MACHINE TST.13

TRIMMING UNIT/DIAMOND MACHINE TST.13 TRIMMING UNIT/DIAMOND MACHINE TST.13 REFERENCE BOOK rel. 02.15 TRIMMING UNIT/DIAMOND MACHINE TST.13 REL. 02.15 ENGLISH LANGUAGE 1 MACHINE DESCRIPTION TST.13 was designed and built for processing methacrylate.

More information

Data Center Cooling. The engineer s choice

Data Center Cooling. The engineer s choice Data Center Cooling The engineer s choice About ebm-papst Inc. Headquarters - Farmington, CT» 250K sq. ft.» Acoustic testing chamber» Complete air testing lab on site» Mechanical/Design Engineering» Electrical

More information

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9 CHAPTER TIG welding Introduction pages - & - WELDING POWER SOURCES DC power sources SMARTY 60 POWER page -5 SMARTY 80 / 0 XL page -6 SMARTY TX 50 page -7 AC/DC power sources SMARTY TX 60 Alu page -8 SMARTY

More information

QZSR Fan Coil. Key features. Specifications. Product code example Cassette Unit QZSR, QZSR-13-2-2-1

QZSR Fan Coil. Key features. Specifications. Product code example Cassette Unit QZSR, QZSR-13-2-2-1 Key features Vertical or horizontal installation Cooling ( pipes) Heating ( pipes or electrical heater) Available pressure up to 80 Pa ECM version for low energy consumption In line with innovative trends

More information

CONTROL/SLAVE Zone. Zone damper for Swegon s WISE System for demand-controlled ventilation

CONTROL/SLAVE Zone. Zone damper for Swegon s WISE System for demand-controlled ventilation CONTROL/SLAVE Zone Zone damper for Swegon s WISE System for demand-controlled ventilation Quick facts Pressure regulation from -300 Pa Flow measurement or flow regulation Optimisation of supply- and extract

More information

The compact unit series

The compact unit series The compact unit series The easy way to maintain a good climate i High, efficient energy recovery with an efficiency of 80 90 % i Energy-saving fan motors utilising EC technology for minimal energy consumption

More information