Local Control Station

Similar documents
Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal T [] C

THE ADVANTAGES ARE YOURS

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

STANDARD MICRO-D CONNECTORS

HARTING Ethernet Cabling 4-poles Overview

DESCRIPTION UNIT QTY RATE TOTAL (KSHS) Supply and install the following: -

Dlp-s & WIRING DEVICES. THE MAXIMUM FReeDOM OF ChOICe. SNAP-ON AND UNIVERSAL TRUNKING FOR high AND LOW CURReNt DIStRIBUtION

I E D C E R T. Net MA N A G E ME N T S Y S T E M ISO 9001: RAVI. Pendant Stations LADY Series

HARTING Ethernet Cabling 8-poles Overview

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

Superlight Compact Nano

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

400 Series - Mini USB Buccaneer

Standard Buccaneer - USB

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

LIEBERT VNSA Installation Sheet

Linear Luminaire with LED Series EXLUX 6402/2

know-how Giant in distributing electricity for industry Prisma GK

ROOF DRAINS TABLE OF CONTENTS

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

Type FTS/FTC. A e. Compliance with Standards. Uses. Features

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Control and Distribution Boxes made of Stainless Steel Series 8150

I N D U S T R I A L C A B L E G L A N D S

Compact pressure switch Flameproof enclosure Ex d Model PCA

Product and functional description

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

PART-II (COMMERCIAL / PRICE BID) DESIGN, SUPPLY AND INSTALLATION OF CUSTOMIZED STEEL LAB FURNITURE.AT N.C.C.S., PUNE

2 Wire Electronic Time Delay Switch. 2 Wire Slave Switch. 3 Wire Electronic Time Delay Switch

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection

COMPACT DATA FAST AND SIMPLE DATA CABLE TRUNKING. Building Solutions Automotive Industry

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

Corporate Profile ROYAL. MODERN ROYAL ELECTRIC Ideal Power Solution MRE ELECTRICAL, INSTRUMENTATION & COMMUNICATION SYSTEMS

I-Line. Accessories. Essential cable installation products for corrugated, smooth wall, and braided cables

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

Standard Buccaneer - Ethernet

BRICK LED Design Ronni Gol

FIRE RESISTANT CABLE CONSTRUCTION OF CABLES

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

PAGE/PARTY. Solutions. GAI-Tronics Page/Party. communication systems. provide paging and. party-line capabilities... two important plant

GROENEVELD AUTOMATIC GREASING SYSTEMS

5SV Residual Current Protective Devices

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

MAC-821SC-E. Centralized On-Off Remote Controller. English ÏÏËÓÈÎ. Русский [FOR INSTALLER] INSTALLATION MANUAL

Switchboard system. NorLine 800

SHORE POWER. Safely Connecting Ships to Shore SAFETY QUALITY INNOVATION VALUE CUSTOMER SERVICE

Mini USB and USB 2.0-IP67 Connector System

LED Sign Module. LED Super Tiny Strip. LED Accessories. LED Power Supply

INSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD LOW VOLTAGE TRACK LIGHTING SYSTEM

Paper on Basbar Trunking System for Electrical Supply to Industrial & commercial Installation

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

PROFIBUS cable. for PROFIBUS-PA and -DP 10/ EN

Ductile Iron Pipe Couplings

MTA UNIVERSAL STATION PEDESTRIAN BRIDGE Los Angeles, CA. Project Manual and Specification 100% PE SUBMITTAL TABLE OF CONTENTS

Aluminium Standard. Technical Data. Included in delivery

DuroSite TM High Bay Lighting

FAQs-Main switchboard design criteria

Industrial Linergy LED

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Wiring diagrams for luminous 1P 1-way switches with 110 V~ or 250 V~ signalling units

E S T I M A T E TENDER FOR ELECTRICAL & DATA CABLING WORK FOR BANK OF INDIA, KALAWAD ROAD BRANCH(GROUND FLOOR)-RAJKOT CITY

WE-350 Series ¼ Turn Electric Actuator

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

NATIONAL COIR RESEARCH AND MANAGEMENT INSTITUTE (NCRMI) KUDAPPANAKUNNU.P.O, THIRUVANANTHAPURAM NOTICE INVITING LIMITED QUOTATION

Switches SWITCHES SWITCHES

Watertight Luminaire, surface, 1x18W / 2x18W / 2x24W / 1x36W / 2x36W / 2x54W

TRANSFORMER FITTINGS & ACCESSORIES

How To Read A Pipe From A Sensor

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

3/2-way Solenoid Valve, direct-acting, NC or NO

UGVCL/SP/591/11KV HT AB CABLE

2013 Wireless Video Intercom INSTALLATION GUIDE

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS

Bolted Connectors & Terminals

How To Wire Wireline Cable To A Cell Phone (New Zealand)

PROFIBUS cable. PROFIBUS DP cables Non-Ex (Hazardous) applications Ex (Hazardous) applications

ABB. Installation Enclosures Meter Boxes. SMB s. DMB s. Enclosures

K17.11 DOOR BOLTS K17 DOORS

Linkeo 19" freestanding cabinets

General information. Your Connection to Light

USB 3.0 Cables. Color. Black Black Black Black Black Black Black Black Black Black

AP Series Industrial Pushbutton Switch

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

How To Build A High Mast Power Plant

TARIFF CODE and updates standard

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

ROLINE THE Difference

Dual Pressure Controls for Refrigeration, Air-conditioning and Heatpump Applications

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

ScottishPower Distribution Cables & Equipment. Metal Theft

Transcription:

Local Control Station As per table given below Weatherproof Local Control Station with Various Combinations WP/PB/1-1 WP/PB/1-1 WP/PB/1-1 WP/PB/2-1 WP/PB/2-1 A B C D E A B C D E Max. No. of Clip-On Type Terminals Options Cat No. 2.5mm 2 Micro 4mm 2 6mm 2 1 2 3 4 5 6 7 8 WP/PB/1-1 10 10 6 * * WP/PB/1-1 14 12 10 * * * WP/PB/1-1 4 4 3 * WP/PB/2-1 14 12 10 * * * * * * * * WP/PB/2-1 14 12 10 * * * * * * Mechanical Data Construction: Cast Aluminium alloy LM-6. IP Protection: IP-66 confirming to IS/ IEC: 60529. Finishing: Epoxy coated as per shade 631/632 of IS-5. Hardware: High tensile M. steel duly cadmium plated. Gasket: Endless neoprene rubber. Mounting: Mounting on wall, column, steel structure etc. Cable Entry: 2 Nos. M20 (F), at Bottom. Canopy: Optional. Electrical Data Wiring: PVC insulated 1.5/2.5 sq. mm stranded Copper Conductor. Terminals: Refer Chart. Earthing: External - 2 Nos - M6, Internal - 1 No. - M6. Standard Options Options Description 1 1 Push Buttons 2 2 Push Buttons 3 1 Fire Alarm Push Button 4 3 Push Buttons 5 2 Push Buttons + Indicating Lamp 6 2 Push Buttons + Selector Switch 7 2 Push Buttons + Selector Switch + Indicating Lamp 8 Breaker Switch D-LCS-7 Type of protection Area Classification Gas Groups Apparatus Std. CIMFR Certificate Weatherproof Safe Area N. A. IS/IEC: 60529 CMRI/TC/P/H1406 & H454

Local Control Station As per table given below Weatherproof Local Control Station with Various Combinations WP/PB/3-1 WP/PB/4-1 A B A B Max. No. of Clip-On Type Terminals Options Cat No. 2.5mm 2 Micro 4mm 2 6mm 2 1 2 3 4 5 6 7 8 WP/PB/3-1 14 12 10 * * * * * * * * WP/PB/4-1 14 12 10 * * * * * * * * Mechanical Data Construction: Cast Aluminium alloy LM-6. IP Protection: IP-66 confirming to IS/IEC: 60529. Finishing: Epoxy coated as per shade 631/632 of IS-5. Hardware: High tensile M. steel duly cadmium plated. Gasket: Endless neoprene rubber. Mounting: Mounting on wall, column, steel structure etc. Cable Entry: 2 Nos. M20 or M25 (F), at Bottom. Canopy: Optional. Electrical Data Wiring: PVC insulated 1.5/2.5 sq. mm stranded Copper Conductor. Terminals: Refer Chart. Earthing: External - 2 Nos - M6, Internal - 1 No. - M6. Standard Options Options Description 1 2 Push Buttons + Ammeter 2 2 Push Buttons + Ammeter + Indicating Lamp 3 3 Push Buttons + Ammeter + Indicating Lamp 4 2 Push Button + 2 Ind. Lamps + S. Switch 5 2 Push Buttons + S. Switch + Ammeter 6 2 Push Buttons + S. Switch + Indicating Lamp 7 2 Push Buttons + Ind. Lamp + Ammeter + Switch 8 Any combination of above Modules/Components. D-LCS-8 Type of protection Area Classification Gas Groups Apparatus Std. CIMFR Certificate Weatherproof Safe Area N. A. IS/IEC: 60529 CMRI/TC/P/H1406 & H454

Local Control Station As per table given below Weatherproof Local Control Station with Various Combinations WP/PB/1-2 WP/PB/2-2 WP/PB/2-2 WP/PB/2-2 WP/PB/1-2 A Cat No. WP/PB/1-2 A Max. No. of Clip-On Type Terminals 2.5mm 2 Micro 4mm 2 6mm 2 WP/PB/2-2 B Options WP/PB/2-2 B 1 2 3 4 5 6 7 8 A B WP/PB/1-2 25 20 15 * * * * * * WP/PB/2-2 25 20 15 * * * * * * * * * Mechanical Data Construction: Cast Aluminium alloy LM-6. IP Protection: IP-65 confirming to IS/IEC: 60529. Finishing: Epoxy coated as per shade 631/632 of IS-5. Hardware: High tensile M. steel duly cadmium plated. Gasket: Endless neoprene rubber. Mounting: Mounting on wall, column, steel structure etc. Cable Entry: As per requirement, As at Bottom. Canopy: Optional. Electrical Data Wiring: PVC insulated 1.5/2.5 sq. mm stranded Copper Conductor. Terminals: Refer Chart. Earthing: External - 2 Nos - M6, Internal - 1 No. - M6. Standard Options Options Description 1 1 Push Button 2 2 Push Buttons 3 3 Push Buttons 4 2 Push Button + Indicating Lamp 5 2 Push Buttons + Selector Switch 6 2 Push Buttons + Ammeter 7 2 Push Buttons + Selector Switch + Ind. lamp 8 Any combination of above Modules/Components. D-LCS-9 Type of protection Area Classification Gas Groups Apparatus Std. CIMFR Certificate Weatherproof Safe Area N. A. IS/IEC: 60529 CMRI/TC/P/H1400 & 1182

Local Control Station As per table given below Weatherproof Local Control Station with Various Combinations WP/PB/3-2 WP/PB/3-2 WP/PB/4-2 WP/PB/4-2 WP/PB/3-2 WP/PB/3-2 WP/PB/4-2 WP/PB/4-2 A B C D Max. No. of Clip-On Type Terminals Max. No. of Options Cat No. 2.5mm 2 Control Micro 4mm 2 6mm 2 Components 1 2 3 4 5 6 7 8 WP/PB/3-2 25 20 15 1 to 5 & 8 * * * * * WP/PB/4-2 40 30 20 5 to 7 & 8 * * * * Mechanical Data Construction: Cast Aluminium alloy LM-6. IP Protection: IP-65/66 confirming to IS/IEC: 60529. Finishing: Epoxy coated as per shade 631/632 of IS-5. Hardware: M. steel duly cadmium plated. Gasket: Neoprene rubber. Mounting: Mounting on wall, column, steel structure etc. Cable Entry: As per requirement, at Bottom. Canopy: Optional Electrical Data Wiring: PVC insulated 1.5/2.5 sq. mm stranded Copper Conductor. Terminals: Refer Chart Earthing: External : 2 Nos - M6, Internal : 1 No. - M6. Standard Options Options Description 1 2 Push Buttons + Selector Switch + Ammeter 2 3 Push Buttons + Selector Switch + Ammeter 3 3 Push Buttons + 2 Selector Switch 4 3 Push Button + 3 Indicating Lamps 5 4PBs+3Sel.Switches+4Ind. lamps+ammeter 6 4PBs+Sel.Switche+2Ind. lamps+a/m+speed Indicator 7 2 Breaker Switches+2 Sel. Switches+2 Ammeter 8 Any combination of above Modules/Components. Type of protection Area Classification Gas Groups Apparatus Standard CIMFR Certificate Weatherproof Safe Area N. A. IS/IEC: 60529 CMRI/TC/P/H1400+1182 & CMRI/TC/P/H43 + 1181 D-LCS-10