System One-Line Diagram

Similar documents
Power/Vac Product Family Application Guide

TA Kahraman Yumak ELK412 - Distribution of Electrical Energy Lab. Notes v Spring web.itu.edu.tr/yumakk. Distance Protection

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

Current Transformers Ratio / Polarity / Types

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

SPECIAL TOPICS ON GROUND FAULT PROTECTION AND PROTECTION COORDINATION IN INDUSTRIAL AND COMMERCIAL POWER SYSTEMS

Short Circuit Current Calculations

Part 1 System Modeling & Studies for Existing Systems

Unified requirements for systems with voltages above 1 kv up to 15 kv

The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies

Properties of electrical signals

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Selecting Current Transformers Part 1 By Darrell G. Broussard, P.E.

Typical Data Requirements Data Required for Power System Evaluation

Substation Automation and Smart Grid

QUESTIONS and ANSWERS RFB , Metal Clad Switchgear and Power Control Room

Pilot-wire differential relay for lines with two or more terminals

Eaton s E-Series protective relay family

Step Voltage Regulators

Cahier technique no. 196

TABLE OF CONTENTS 1.0 INTRODUCTION PURPOSE DEVIATION INTERTIE PROTECTION REQUIREMENTS... 4

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

E&I MAINTENANCE ENTRY TEST ENABLING OBJECTIVES. DESCRIBE hazards and precautions taken to avoid injury in the workplace.

Engineering Specification

Primary and Secondary Electrical Distribution Systems

Medium Voltage Switchgear

32VFD Variable Frequency Drives for Centrifugal Chillers

VOLTAGE REGULATOR AND PARALLEL OPERATION

100% Stator Ground Fault Detection Implementation at Hibbard Renewable Energy Center. 598 N. Buth Rd 3215 Arrowhead Rd

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Diesel Engine Driven Generators Page 1 of 6

Electronic overload relay EF65, EF96 and EF146

The following table shows approximate percentage wise the

How To Understand The Electrical Power Supply Of A Power Supply System

How To Choose A Transformer

Inverter / Charger Installation General Operations and AC and DC Connections

HIGH VOLTAGE SHORE CONNECTION

Permissible ambient temperature Operation Storage, transport

Paralleling Switchgear

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

EET272 Worksheet Week 8

Industrial Automation Commonly-Used Terms

Understanding Power Factor and How it Affects Your Electric Bill. Presented by Scott Peele PE

Short-circuit, Protective Device Coordination & Arc Flash Analysis. By Albert Marroquin Operation Technology, Inc.

T Substation Maintenance and Commissioning Test Equipment

SECTION VARIABLE FREQUENCY DRIVES

(PREVIEW) Indian Standard COMMON SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS

Simple Methods for Calculating Short Circuit Current Without a Computer By Dennis McKeown, PE GE Senior System Application Engineer

Electronic overload relay EF19 and EF45

GUIDE FOR TESTING POWER TRANSFORMERS

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

Suitable for Emergency, Peak and Prime Power System Applications. Low Voltage Automatic Transfer Switch Systems

101 BASICS SERIES LEARNING MODULE 3: FUNDAMENTALS OF ELECTRICAL DISTRIBUTION. Cutler-Hammer

Earth Fault Detection Basics in Theory

CIRCUIT BREAKER INTERRUPTING CAPACITY AND SHORT-TIME CURRENT RATINGS

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

The standards mentioned in this document

Electronic Trip Circuit Breaker Basics Circuit Breaker Application Guide Class 0600

Hyperlinks are Inactive

Current and voltage measuring relays

3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

National Craft Assessment and Certification Program S P E C I F I C A T I O N S

MEDIUM VOLTAGE METAL CLAD SWITCHGEAR

Specification Guide. for RVAC. Direct Replacement. AC Medium Voltage. Circuit Breakers

HIGH VOLTAGE CALCULATIONS / EVALUATIONS. West Virginia Office of Miners Health, Safety & Training

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

How the National Grid System Operates. Chris Gorman Lead Account Executive Syracuse

Schneider Electric Services: life-cycle solutions for electrical distribution equipment. Scopes of Work for Electrical Acceptance Testing

Electron S.R.L. A29 ELECTRICAL POWER SYSTEM TRAINERS. Production Transmission Distribution

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Choosing the Best Solution for Reducing Arc Energy

Type SA-1 Generator Differential Relay

DIMENSIONING OF CURRENT TRANSFORMERS FOR PROTECTON APPLICATION

7.2KV SL400 Withdrawable Vacuum Contactor-Fuse Combination Units

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Interconnection of Generators to EDI s Distribution System

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

FREJA 300 Relay Testing System

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

SECTION 20. ELECTRICAL AND ELECTRONIC SYMBOLS

Medium voltage circuit breaker

Operation and Maintenance manual. fusible shunt trip switch

IEC and IEEE Standards for High-Voltage Switchgear and Controlgear Present Situation and Future Evolution

NATIONAL CERTIFICATE (VOCATIONAL)

Fusible Disconnect Switch

Eaton s Electrical Services & Systems. Technical Training Safety Training

Electrical Shore Connections / Cold Ironing

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

The following components are common to most cubicles; this example is an ABB HK cubicle.

Bus differential relay REB phase 1MRK BEN Page 1 Issued: September 2006 Revision: C Data subject to change without notice

Test & Data Management Software

Transcription:

Section Contents 2 Section 2 System One-Line Diagram Page INTRODUCTION... 2-2 DEVELOPING A ONE-LINE DIAGRAM... 2-2 PRELIMINARY ONE-LINE DIAGRAM... 2-4 PARTIALLY DEVELOPED ONE-LINE DIAGRAM... 2-5 DEVELOPED ONE-LINE DIAGRAM... 2-6 ADAPTING ONE-LINE DIAGRAM TO EQUIPMENT... 2-8 REFERENCES... 2-10 2-1

System One-Line Diagram INTRODUCTION The first step in preparing a specification for metalclad switchgear is to develop a one-line diagram. A one-line diagram (single line) is a diagram that shows, by means of single line and graphic symbols, the course of an electric circuit or system of circuits and the component devices or parts used therein. (See Ref. 1 on Page 2-10.) When preparing switchgear one-line diagrams, use graphic symbols in accordance with IEEE and ANSI standards listed in References 2 and 3 on page 2-10. One-line diagrams employ device function numbers which, with appropriate suffix letters, are used to identify the function of each device in all types of partially automatic, fully automatic, and in many types of manual switchgear. A complete list of such device function numbers is published in C37.2.1996 and shown in Table 2-2. DEVELOPING A ONE-LINE DIAGRAM To illustrate the development of a one-line diagram, a typical resistance grounded system has been chosen. The same general procedures would apply to solidly grounded distribution systems. Three steps are used in producing a one-line diagram: the preliminary diagram, followed by the partially developed diagram, and finishing with the developed diagram. The abbreviations used for principal meters, instruments, and other devices (not including relaying, which is listed in Table 2-2), as found in the application guide, are listed in Table 2-1. Each device in an automatic switching equipment has a device function number which is placed adjacent to or within the device symbol on all wiring diagrams and arrangement drawings so that its function and operation may be readily identified. These numbers are based on a system which was adopted as standard for Automatic Switchgear by the American National Standards Institute and appear in ANSI C37.2-1996. (See Ref. 4 on page 2-10.) Table 2-2 is a list of device numbers and functions as taken from this standard. Table 2-1. Abbreviations Abbr. Description Abbr. AM Ammeter S Synchronous motor AS Ammeter switch S/A Surge arrester Aux Auxiliary SS Synchronizing switch Bkr Breaker SYN Synchroscope CO Cut off switch SYN BR Synchronizing bracket CPT Control power transformer TD Test device CS Control switch VAR Varmeter (one-line) CT Current transformer VARM Varmeter (device list) FA Field ammeter VM Voltmeter FM Frequency meter VR Voltage regulator G Generator VS Voltmeter switch GS Governor switch WHM Watthour meter I Induction motor WHDM Watthour demand center VT Voltage transformer WM Wattmeter 2-2

Section 2 Table 2-2. ANSI Standard Device Function Numbers Dev. No. Function 1 Master Element 2 Time-Delay Starting or Closing Relay 3 Checking or Interlocking Relay 4 Master Contactor 5 Stopping Device 6 Starting Circuit Breaker 7 Anode Circuit Breaker 8 Control Power Disconnecting Device 9 Reversing Device 10 Unit Sequence Switch 11 Multifunction Relay 12 Over-Speed Device 13 Synchronous-Speed Device 14 Under-Speed Device 15 Speed or Frequency Matching Device 16 Reserved for future application 17 Shunting or Discharge Switch 18 Accelerating or Decelerating Device 19 Starting-to-Running Transition Contactor 20 Electrically Operated Valve 21 Distance Relay 22 Equalizer Circuit Breaker 23 Temperature Control Device 24 Reserved for future application 25 Synchronizing or Synchronism-Check Device 26 Apparatus Thermal Device 27 Undervoltage Relay 28 Flame Detector 29 Isolating Contactor 30 Annunciator Relay 31 Separate Excitation Device 32 Directional Power Relay 33 Position Switch/Cell Switch 34 Master Sequence Device 35 Brush-Operating or Slip-Ring Short-Circuiting Device 36 Polarity or Polarizing Voltage Device 37 Undercurrent or Underpower Relay 38 Bearing Protective Device 39 Mechanical Condition Monitor 40 Field Relay 41 Field Circuit Breaker 42 Running Circuit Breaker 43 Manual Transfer or Selector Device 44 Unit Sequence Starting Relay 45 Atmospheric Condition Monitor 46 Reverse-Phase or Phase-Balance Current Relay 47 Phase-Sequence Voltage Relay 48 Incomplete Sequence Relay 49 Machine or Transformer Thermal Relay 50 Instantaneous Overcurrent or Rate-of-Rise Relay Dev. No. Function 51 AC Time Overcurrent Relay AC Circuit Breaker 53 Exciter or DC Generator Relay 54 Reserved for future application 55 Power Factor Relay 56 Field Application Relay 57 Short-Circuiting or Grounding Device 58 Rectification Failure Relay 59 Overvoltage Relay 60 Voltage or Current Balance Relay 61 Reserved for future application 62 Time-Delay Stopping or Opening Relay 63 Pressure Switch 64 Ground Protective Relay 65 Governor 66 Notching or Jogging Device 67 AC Directional Overcurrent Relay 68 Blocking Relay 69 Permissive Control Device 70 Rheostat 71 Level Switch 72 DC Circuit Breaker 73 Load-Resistor Contactor 74 Alarm Relay 75 Position Changing Mechanism 76 DC Overcurrent Relay 77 Pulse Transmitter 78 Phase-Angle Measuring or Out-of-Step Protective Relay 79 AC Reclosing Relay 80 Flow Switch 81 Frequency Relay 82 DC Reclosing Relay 83 Automatic Selective Control or Transfer Relay 84 Operating Mechanism 85 Carrier or Pilot-Wire Receiver Relay 86 Locking-Out Relay 87 Differential Protective Relay 88 Auxiliary Motor or Motor Generator 89 Line Switch 90 Regulating Device 91 Voltage Directional Relay 92 Voltage and Power Directional Relay 93 Field-Changing Contactor 94 Tripping or Trip-Free Relay } 95 Used only for specific applications 96 in individual installations 97 where none of the 98 assigned numbered functions 99 from 1-94 are suitable. 2-3

System One-Line Diagram Figure 2-1. Preliminary one-line diagram PRELIMINARY ONE-LINE DIAGRAM On this diagram (Figure 2-1) show: System voltage and major component ratings. Major medium-voltage cable lengths, sizes,and construction. (Not shown in example.) Approximate number and ratings of all motors. Supply system available short-circuit capabilityin symmetrical MVA (plus X/R ratio) or per unit R+jX (on a given basis). Using data on the one-line diagram, perform short circuit calculations: 2-4 Compare the calculated first cycle (Momentary) asymmetrical current duty with the close and latch circuit breaker capability. Compare the calculated 1-1/2 to 4-cycle (interrupting) current duty with the circuit breaker symmetrical interrupting capability. (See Ref. 5 on page 2-10.) Determine the applicable circuit breaker ratings. Compare the feeder cable short-circuit heating limit with the maximum available shortcircuit current time K t times K o. (See Ref. 10 and 11 on page 2-10.) Note that the calculations performed in accordance with Reference 5 (on page 2-10) determine only medium and high-voltage circuit breaker ratings. Perform short-circuit studies to determine relay operating currents in accordance with procedures outlined in Reference 6 (on page 2-10). For other than power circuit breakers, refer to the appropriate ANSI standard for short-circuit calculation procedure.

Section 2 Figure 2-2. Partially developed one-line diagram PARTIALLY DEVELOPED ONE-LINE DIAGRAM Using the sample system, a partially developed one-line diagram is shown in Figure 2-2. On this diagram, the specifier should: Show the results of the short-circuit calculations performed, using the preliminary one-line diagram and selected circuit breaker ratings. Show ratings selected for external devices, such as grounding resistors, control power transformers, considering the type of protective relaying instrumentation and metering required. Select tentative current transformer (CT) ratios inconsidering the maximum transformer rating, motor ratings, and ampacity of the circuits involved. (See Section 5.) Locate current transformers and voltage transformers, considering the type of protective relaying instrumentation and metering required. 2-5

System One-Line Diagram 50 51 Phase Time & Instantaneous Relay 87T G Transformer Ground Differential Relay 51N Residually Connected Time Overcurrent Relay 86T Transformer Differential Lockout Relay 51G Ground Time Overcurrent Relay 87M Motor Differential Relay 50 GS Ground Sensor Instantaneous Overcurrent Relay 86M Motor Lockout Relay 51 B Phase Time Overcurrent Relay 87 B Bus Differential Relay 51N B Residually Connected Time Overcurrent Relay 86 B Bus Differential Lockout Relay 87T High Speed Transformer Differential Relay 62 Time (Typical) 0.5 to 5 seconds Figure 2-4. Typical Protective Relay Symbols DEVELOPED ONE-LINE DIAGRAM A developed one-line diagram for the system is shown in Figure 2-3. In addition to the information shown on the partially developed one-line diagram, the specifier should: Show all relaying, instrumentation, and metering. Select relaying, instrumentation, and metering using the information given in Sections 5 and 6 of this Application Guide. Confirm the selection of relay ratings and characteristics by performing a complete system short-circuit and coordination study. (See Ref. 7 through 10 on page 2-10.) Include in the study an examination of all circuits for compliance with applicable local and national codes. (See Ref. 11 on page 2-10.) Verify that all circuit conductors are applied within the conductor short-circuit heating limit. (See Ref.10 on page 2-10.) 2-6

Section 2 115kV - 60Hz 5000MVA S/C X/R = 8 (3) Station Class Surge Arrestors (3) 150/5 (3) 100/5 50/51 51N 12/16/20 MVA 115kV/13.8kV Z=8% 63 FPX (1) 200/5 400A -10 sec Utility Metering TPR - SR745 150/151, 151N 87T, 87TG 50/51, 51G, 51N EPM (2) 14400-120V Bus 1 1200A - 13.8kV (3) 400/5 (3) 400/5 (3) 300/5 (3) 300/5 (1) 50/5 (1) 50/5 (1) 50/5 (1) 50/5 Substation Feeders (3) 50/5 S Figure 2-3. Developed one-line diagram. Calculated Maximum Available Short Circuit at Each Main 13.8Kv Bus 1st Cycle - 12.4kA Asym 1.5 Cycles - 7.2kA Sym 115kV - 60Hz 5000MVA S/C X/R = 8 (3) 150/5 (3) Station Class Surge Arrestors 13.8kV Breakers Type VB1-15-20kA-1200A K=1.0 (3) 100/5 50/51 51N 86T 125VDC from Station Battery 12/16/20 MVA 115kV/13.8kV Z=8% 63 FPX (1) 200/5 400A -10 sec Utility Metering TPR - SR745 150/151, 151N 87T, 87TG 50/51, 51G, 51N EPM (2) 14400-120V MPR - SR469 50/51, 50/51G, 48, 49, 87, 27, 59, 47, 86, V, A, W, Var, PF N.O. Bus 2 1200A - 13.8kV (3) 400/5 (3) 400/5 (3) 300/5 (3) 300/5 87B-1 87B-2 3 3 86B- 1 1 86B- 2 (1) 50/5 (1) 50/5 (1) 50/5 (1) 50/5 1 5000HP 1.0 PF Trips All Breakers on Bus 1 & Tie Trips All Breakers on Bus 2 & Tie Substation Feeders (3) 50/5 S 86T MPR - SR469 50/51, 50/51G, 48, 49, 87, 27, 59, 47, 86, V, A, W, Var, PF 5000HP 1.0 PF 2-7

System One-Line Diagram Arrangement 1 Arrangement 2 Figure 2-5. Two possible arrangements of Power/Vac Metalclad switchgear. 2-8

Section 2 ADAPTING ONE-LINE DIAGRAM TO EQUIPMENT Figure 2-5 shows two possible arrangements of Power/Vac metalclad switchgear as developed from the one-line diagram in Figure 2-3. Both save space when compared to onehigh metalclad switchgear, and both permit the addition of future units on either end. The arrangements shown are not the only ones which can be developed to satisfy the conditions of the one-line diagram. Use the information in Sections 6 and 7 to adapt the oneline diagram to the equipment and develop a suitable arrangement for the particular installation. 2-9

System One-Line Diagram Standards REFERENCES ANSI IEEE Standard Standard Title 1. C42.100-1992 100-1977 IEEE Standard Dictionary of Electrical and Electrical Terms. 2. Y32.2-1975 315-1975 Graphic Symbols for Electrical and Electronic Diagrams. 3. Y14.15-1966 (R1973) Electrical and Electronics Diagram. 4. C37.2-1996 Electrical Power System Device Function. 5. C37.010-1999 Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis. 6. C37.95-1989 (R1994) 357-1973 IEEE Guide for Protective Relaying of Utility-Consumer Interconnections. 7. 141-1969 Electric Power Distribution for Industrial Plants. 8. 142-1972 IEEE Recommended Practice for Grounding of Industrial and Commercial Power Systems. 9. 241-1974 IEEE Recommended Practice for Electrical Power Systems in Commercial Buildings. 10. 242-1975 IEEE Recommended Practice for Protection and Coordination of Industrial and Commercial Power Systems. Books 11. Industrial Power Systems Handbook D.L. Beeman, Editor McGraw-Hill Book Co., 1955. Publications 12. GEA-10049H Power/Vac Metalclad Switchgear. 13. GET-6600F Power/Vac Application Guide. Standards may be purchased from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 Institute of Electrical and Electronics Engineers, Inc. Service Center 445 Hoes Lane Piscataway, NJ 08854 National Electrical Manufacturers Association Publication Department 2101 L St. N.W. Suite 300 Washington, D.C. 20037 National Fire Protection Association 470 Atlantic Avenue Boston, MA 02210 2-10