ErP POWERBOX GF FANS - ESTOC TARGE FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

Similar documents
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

TFSR & TFSK Roof Fans

UDSA - UDSBD unit heater

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

Air Comfort. Technical Catalogue > Roof Fan STOF

THE ErP DIRECTIVE 2009/125/EC KEY FACTS» REGULATIONS 327/ /2009. ErP. - Version 2.0

ECOCIAT. Domestic hot water heat recovery unit

squrboxbox heat recovery squrboxbox I technical information

RPV - RP - RA air handling units

Surface Technology. Centrifugal Fan GMD

CADB and CADT-D / DI / DC Series

systemair Smoke Extract Fans Keep Your Cool: Smoke Extraction with Systemair

RFHD. ROOF CENTRIFUGAL FANS WITH ATEX CERTIFICATION CEE ExII2G Ex d. According EU Regulation

Under sill units. Type FSL-B-ZAS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

FULL DC INVERTER SYSTEMS

The ventilation of the future.

FAN & BLOWER CENTRIFUGAL FANS

HEAVY DUTY STORAGE GAS

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

Advances in Gas Cooler Design and the New Gas Cooler Product Selector

EC-fans. Energy efficient and environmentally friendly

Series description: Wilo-Drain TC 40

WTW SWANTM. Linear slot air diffusers of wall-to-wall design for ceilings

Conlift1, Conlift2, Conlift2 ph+

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

SECTION MORTUARY REFRIGERATORS

ICQ Series - square centrifugal

The compact unit series

Installation and maintenance instructions. Danfoss Vent

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Transformer oil cooler ALFA A02

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

CRAC Precision climate control units for data centres

HERZ-Thermal Actuators

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

SECTION GENERAL PROVISIONS FOR HVAC WORK

Installation, operation and maintenance manual TX 35A

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

Appendix - Controllers 179

AC axial fans A series

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

SECTION HEAT PUMPS

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

BENCH TECH 150. IVD In vitro diagnostic-medical device. General information Type of instrument: Bench chemical hood. Technical datasheet BenchTech150

Data Center Cooling. The engineer s choice

HP switch LP switch Discharge thermo Comp. Surface thermo

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

CRN A-F-G-E-HQQE 3x400D 50 HZ

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

york air-conditioning products Residential & VRF News 2015

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Topvex SX/C, Topvex TX/C. Air Handling Unit

Industrial Generator Set Accessories

Cable Plug acc. to DIN EN , Form A

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

CE6500 Energy Recovery Ventilator

Contents. Spare parts list...16 Electrical wiring...17 Electrical components...18 Miscellaneous / Notes Subject to change without notice DHA 250

SWIMMING POOL HEAT PUMP Owners Manual

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

QZSR Fan Coil. Key features. Specifications. Product code example Cassette Unit QZSR, QZSR

Energy Saving ECM Motors and Fans Ventilation Catalogue

PS1800 Centrifugal Pumping Systems

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

Swirl diffuser VSKA. Product facts. Quick selection. Swirl diffuser VSKA. Connection box ATTB. Product code example:

Photovoltaic Solar Energy Unit EESFB

FLEXIT S3 X/TT A3 X/TT K3 X/TT S3 R S3 RK

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Ventilation Solutions Product Range > Fans

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

PLASTIC VOLUME CONTROL DAMPERS OVERVIEW TYPE: GGB

3/2-way Solenoid Valve, direct-acting, NC or NO

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

8W! consumption. 26,5 db IP45. BATHROOM EXTRACT FANS SILENT-100 DESIGN 3C Series

Centrifugal Fans and Pumps are sized to meet the maximum

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Grilles & Diffusers Series LFP Incorporating

Thyristor-controlled power supplies and battery chargers

Centrifugal Fans direct driven with scroll. Issue 1.3 November 2012

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Commercial Gas Furnace Upflow

Floodlight Range Installation Guide

Please also see 10 golden rules for correct Saniflo installation on

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Pre-site Installation Instructions for Aga Electric Cooker Models Electric C Electric E

Cool Design for Homes and Offices

PANDA SPRAY BOOTH FILTER INFORMATION

Transcription:

129 POWERBOX GF FANS - ESTOC TARGE FEATURES Sizes from 355 to 63 mm diameter Air flow up to 4. m 3 /s Static pressures up to 13 Pa Adjustable controllable external rotor motors Multiple outlet orientations Motor located out of air stream Air discharged at 9 degrees ELECTRICAL SUPPLY 22-24V/5Hz/1f 38-42V/5Hz/3f TEMPERATURE RANGE Only for use at 1ºC or above, which makes it exempt from ErP legislation. SIZES 355, 4, 45, 5, 56 and 63. FEATURES AND CONSTRUCTION The Estoc Targe casing is galvanized and made from sheet steel with PentaPost Construction and acoustic insulation made from fibre glass with a thickness of 2 mm. Can be horizontal or vertical mounted with weather proof hood and has removable side panels. Drip tray included as standard. IMPELLER The Estoc Targe are equipped with high efficiency backward curved centrifugal impellers made of aluminium. MOTOR Motor is situated out of air stream. The impellers together with the external rotor motors are dynamically balanced to quality standard G2,5 DIN ISO 1941 PRODUCT CODE Estoc Targe 5-355-1 ESTOC Targe = Product Name 5 = Box Size 355 = Spigot Diameter size 1 = 1f or 3 = 3f ie, 5 = 5mm; 67 = 67mm; 8 = 8mm; 1 = 12mm ErP COMPLIANT 215 ACCESSORIES (Pages 143-15) - CONTROLLERS (Pages 219-267) The range of accessories include dampers, flexible connectors, service doors, outlet covers, guards, side covering and insulating connections. A quick reference guide is shown below. SPEED CONTROLLERS Speed is variable using auto transformers and inverter control with auxiliary electronic control option and includes a integrated emergency switch (see pages 219-267). SOC STP SWR SFC Mounting track/smt Electronic Controller Controls Transformer Controls Inverter Fläkt Woods 9513 GB 215.8 Specifications are subject to alteration without notice

13 PRODUCT AND ELECTRICAL DETAILS ErP COMPLIANT 215 Product Code Product Number Speed rpm Motor Frame Electrical Supply Motor (kw) Electrical Current Full Load Current (A) Starting Current (A) Wiring Diagrams **Speed Controllers Electronic/ Transformer Maximum Operating Temp C Breakout *Sound Level db(a) (3m) Estoc Targe 5-355-1 GF53551 136 Integral 22-24 V/5 Hz/1 Ph.31 1.4 3.5 CD36 ME1.3 11 35 Estoc Targe 67-4-1 GF6741 127 Integral 22-24 V/5 Hz/1 Ph.53 2.2 4.84 CD36 ME1.3 9 39 Estoc Targe 67-45-1 GF67451 138 Integral 22-24 V/5 Hz/1 Ph 1 4.6 11.96 CD36 ME1.6 8 44 Estoc Targe 5-355-3 GF53553 136 Integral 38-42 V/5 Hz/3 Ph.31.72 2.59 CD331 TDID 2.5 11 35 Estoc Targe 67-4-3 GF6743 124 Integral 38-42 V/5 Hz/3 Ph.46.95 2.75 CD331 TDID 2.5 1 38 Estoc Targe 67-45-3 GF67453 138 Integral 38-42 V/5 Hz/3 Ph.94 1.75 8.75 CD331 TDID 2.5 1 44 Estoc Targe 8-5-3 GF853 138 Integral 38-42 V/5 Hz/3 Ph 1.5 3 14.7 CD332 TDID 4 8 47 Estoc Targe 8-56-3 GF8563 141 Integral 38-42 V/5 Hz/3 Ph 2.5 7 24.5 CD332 TDID 8 1 49 Estoc Targe 8-63-3 GF8633 1445 Integral 38-42 V/5 Hz/3 Ph 4.4 8 46.4 CD332 IDDXF 54 7.2 9 53 Estoc Targe 2-63-3 GF1633 146 Integral 38-42 V/5 Hz/3 Ph 6 1.8 62.64 CD332 IDDXF 54 7.2 75 91 *Sound power levels are average dba at 3 metres distance over sphere, under free field conditions and are presented for comparative purposes only. Values shown are those at the mid-point of the performance curve. **For speed controllers, please see pages 219-267. For ErP efficiency ratings and grades please refer to our Fan Selector for more information. DRAWINGS AND DIMENSIONS 355-5 56-63 A A a* a* d D b* B C d D b* B C Product Code All dimensions shown in mm A a* B b* C Ø D Ø d ESTOC TARGE 5-355 42 19 41 38 5 365 228 36 ESTOC TARGE 67-4 5 23 58 55 67 44 257 55 ESTOC TARGE 67-45 5 23 58 55 67 545 289 62 ESTOC TARGE 8-5 59 31 71 68 8 54 325 95 ESTOC TARGE 8-56 74 31 71 68 8 57 362 1 ESTOC TARGE 8-63 8 31 71 68 8 64 41 15 ESTOC TARGE 12-63 8 37 9 9 12 64 41 165 Products in bold are available from our UK Distributors on next day delivery, if ordered by 4pm. Please call to confirm availability on 126 222 555. Weight Max (kg) Fläkt Woods 9513 GB 215.8 Specifications are subject to alteration without notice

131 PERFORMANCE CHARTS ESTOC TARGE 5-355-1 - GF53551 5 45 4 35 3 25 2 16V 24V 15 13V 145V 1 15V 5 6V.1.2.3.4.5.6.7.8.9 ESTOC TARGE 67-4-1 - GF6741 6 5 4 3 16V 24V 2 145V 13V 1 15V 6V.2.4.6.8 1 1.2 1.4 ESTOC TARGE 67-45-1 - GF67451 7 6 5 24V 4 3 13V 145V 16V 2 15V 1 6V.2.4.6.8 1 1.2 1.4 1.6 1.8 2 Fläkt Woods 9513 GB 215.8 Specifications are subject to alteration without notice

132 PERFORMANCE CHARTS ESTOC TARGE 5-355-3 - GF53553 45 4 35 3 25 2 23V 28V 4V 15 18V 1 14V 5.1.2.3.4.5.6.7.8.9 ESTOC TARGE 67-4-3 - GF6743 6 5 4 3 2 23V 28V 4V 18V 1 14V.2.4.6.8 1 1.2 1.4 ESTOC TARGE 67-45-3 - GF67453 8 7 6 5 4 3 23V 28V 4V 18V 2 14V 1 1 1.2 1.4 1.6 1.8 2 Fläkt Woods 9513 GB 215.8 Specifications are subject to alteration without notice

133 PERFORMANCE CHARTS ESTOC TARGE 8-5-3 - GF853 9 8 7 6 4V 5 4 3 18V 23V 28V 2 14V 1.5 1 1.5 2 2.5 3 ESTOC TARGE 8-56-3 - GF8563 1 9 8 7 4V 6 5 4 14V 18V 23V 28V 3 2 1 1 1.5 2 2.5 2.5 3 3.5 ESTOC TARGE 8-63-3 - GF8633 14 12 1 4V 8 6 4 2.5 1 1.5 2 2.5 3 3.5 4 4.5 Fläkt Woods 9513 GB 215.8 Specifications are subject to alteration without notice

134 PERFORMANCE CHARTS ESTOC TARGE 12-63-3 - GF1633 16 14 12 1 8 6 4V 4 2 1 2 3 4 5 6 7 INSTALLATION GUIDE Outdoor installation PowerBox GF Estoc Targe Axial air flow (9º discharge available) All accessories supplied separately Centrifugal Discharge Centrifugal on both sides - free discharge Duct Flexible connection AIRFLOW DIRECTION Flexible connection Mounting track/smt When the Estoc Targe is used externally with a horizontal outlet an additional weather roof/cowl is available if required. Fläkt Woods 9513 GB 215.8 Specifications are subject to alteration without notice

135 WIRING DIAGRAMS - ESTOC TARGE CD36 ESTOC TARGE AC 1PH CD36 INTO MOTOR WINDINGS Z2 CAPACITOR YELLOW/GREEN LIVE IN WHEN SAFETY CIRCUIT USED AND FIT LINK ISOLATOR 8 6 2 4 L N OUTPUT Z2 V2 TERMINAL BLOCK L N E FACTORY ISOLATOR SWITCH 1 2 3 4 5 6 7 8 9 EARTH BLUE L N EXTERNAL SAFETY SWITCH CD331 TARGE 3PH 355-45 CD332 TARGE 3PH 5-63 NO NC PE 1 2 3 4 5 NO NC PE ISOLATOR ORANGE 2 1 BLUE RED 4 3 6 8 1 12 14 5 7 9 11 13 ISOLATOR 2 1 4 3 6 5 8 1 12 14 7 9 11 13 NOT USED 16 15 NOT USED L1 L2 L3 NO NC PE L1 L2 L3 NO NC PE Fläkt Woods 9513 GB 215.8 Specifications are subject to alteration without notice

ALSO AVAILABLE FROM THE WOODS RANGE JMv Aerofoil MaXfan 2 JM Aerofoil HT JM Aerofoil JM Bifurcated Series 33 Plate Fans Cased & Plate Axial Accessories Tube Fans Sabina EC Box Fans Daisho AC Box Fans Daisho EC Box Fans Estoc Estoc Targe Estoc EC Tube & Box Accessories Roof Units Horizontal Roof Units Vertical Fire Dampers Iris Dampers Fire Valves Valves Supply KE Valves Extract KK Valves Exhaust VEFS Nozzles DK & DR Louvres/ Cowls EYMA and DYMA External Louvres USAV Controllers Selected products available from our UK Distributors on next day delivery, if ordered by 4pm. Please call 126 222 555 for more information. Fläkt Woods 9513 GB 215.8 Specifications are subject to alteration without notice