1 SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor and a 5 year parts warranty on the titanium heat exchanger. Please contact your supplying dealer in the event of a claim. This heat pump is designed for domestic use between May and September. To achieve satisfactory performance a minimum ambient air temperature of 15 C is required. The heat pump needs to be run for a minimum of 8 hours in 24 during the warmest part of each day. A solar or heat retention swimming pool cover must be used. HeatSeeker Swimming Pool Heat Pump: Page 1 of 10
2 CONTENTS A. Positioning B. Connecting Pipe Work C. Sizes D. Starting the Heat Pump E. Setting the Temperature F. Checking the Status G. Changing the Mode H. Auxiliary Mode I. Winterising and Maintenance J. Troubleshooting: Error Codes K. Troubleshooting: Parameter Settings L. Accessories M. Technical Information HeatSeeker Swimming Pool Heat Pump: Page 2 of 10
3 A. Positioning Your Swimming Pool Heat Pump 1. For correct operation air must be free to circulate around the heat pump. Do not place the unit in a shed, greenhouse or similar. This unit is designed to be placed outdoors only. 2. Ensure there is at least 1000mm (1.0m) of clearance all around each side of the heat pump to allow air circulation and access for maintenance. 3. Do not block the top air exit where the fan expels air upwards from the unit. There must be no obstruction above this air exit for at least 2000mm (2.0m). 4. You should position the heat pump so that the control panel does not face directly towards the sun. 5. The heat pump must be upright. 6. The distance between the heat pump and the pool / plant room should be as short as practically possible to reduce pressure and heat loss in the pipe work. 7. Insulating the pipe work will assist with the prevention of heat losses. 8. An isolator switch should be installed (by a qualified electrician) near the heat pump. 9. The electrical supply to the heat pump must be protected by a 30mA RCD. 10. The air inlets and outlets must not be obstructed or blocked. 11. Even though the heat pump is low noise, it must be positioned so as to be considerate to neighbours. 12. Your heat pump must be placed on a solid base. 13. Condensation will drip from underneath the heat pump, your base must be able to tolerate this. B. Connecting Your Swimming Pool Pipe Work 1. The pool water is fed through the heat pump by a swimming pool pump. 2. The heat pump must be installed after (down stream) the swimming pool filter so clean, filtered water passes through it. 3. Double union ball valves must be fitted just before the heat pump inlet and just after the outlet to aid servicing and winterising. 4. Each heat pump has a maximum water flow rate. If the flow via the pool pump is higher than this then a by-pass should be installed. Consult your supplying dealer. 5. Each heat pump also has a minimum flow rate, below this the heat pump will not operate. Consult your supplying dealer. 6. Pipe work of less than 1½" diameter should not be used. 7. Fit a union nut onto each pipe. 8. Push the gasket over the pipe until the gasket is about 5-10mm from the edge of the pipe. You may need to lubricate the gasket. 9. Insert the pipe into the heat pump and tighten the union nut. 10. The union must only be hand tightened. 11. If the swimming pool is equipped with a chlorinator, brominator, or possibly chemical control with acid and chlorine pumps, these must be in the return pipe work after the heat pump and a non-return valve used. Any dosing system must be the final equipment before the water returns to the swimming pool. Damage caused to the heat pump by chemical dosing units is not covered by warranty. 12. Any heat exchanger or electric heater fitted as auxiliary heating must be installed after (down stream from) the heat pump so as to avoid pre-heating the pool water before it enters the heat pump. HeatSeeker Swimming Pool Heat Pump: Page 3 of 10
4 C. Sizes of Your Swimming Pool Heat Pump WBR-17.0H-A WBR-21.0H-A-S A B C F G HeatSeeker Swimming Pool Heat Pump: Page 4 of 10
5 D. Starting Your Swimming Pool Heat Pump 1. Do not switch on the power to your heat pump unless your swimming pool pump is running and you have a good flow rate. Required flow rates are given in the technical information section. 2. Switch on the main power supply to the heat pump. The display will briefly show all options. Start / Stop Mode Set Aux 3. After a few seconds the display shows ROOM and a temperature. This is the temperature of the air surrounding the heat pump. 4. Push the START/STOP button and await the display to show the inlet and outlet temperature. 5. Note that when you first push the START/STOP button the heat pump fan and compressor will not start immediately. 6. If the water flow from the pool pump is correct, the heat pump will start after a 2-3 minute pause due to a delayed start facility. 7. When the heat pump is operational the display will show temperatures for the pool water inlet and outlet. HeatSeeker Swimming Pool Heat Pump: Page 5 of 10
6 E. Setting the Temperature of Your Swimming Pool Heat Pump 1. If your heat pump fan and compressor is running press the START/STOP button to make the heat pump enter its standby mode. 2. Press the set button repeatedly until SET NO 01 shows with the set point temperature in degrees C. 3. Use the up arrow button and the down arrow button to adjust the set point temperature to your desired point. If you have a liner type swimming pool do not exceed the recommended maximum temperature for the liner (often 28 C). 4. The display will return to the standby mode after a few seconds. 5. Restart the heat pump by pressing the START/STOP button. 6. After the 2 3 minute delay the heat pump will re-start with the new set temperature. F. Checking the Status of Your Swimming Pool Heat Pump 1. When the heat pump is running press the up or down arrow to scroll through the status readings as below. 2. IN & OUT are the respective temperatures at the water inlet and outlet. Note that when you have a good flow rate through the heat pump the difference may be less than 1 C so it appears there is no difference. 3. P1 is the temperature of condenser 1, P2 is the temperature of condenser 2. Note that some models have just one condenser so a reading may not be present for both P1 & P2. 4. ROOM is the temperature of the air around the heat pump. HeatSeeker Swimming Pool Heat Pump: Page 6 of 10
7 G. Changing the Mode of Your Swimming Pool Heat Pump 1. In some regions the swimming pool heat pump is equipped with the option to cool the swimming down. 2. Make sure the heat pump is in standby (power on but fan and compressor not running) by using the START/STOP button. 3. Press the MODE button to scroll through the available modes. 4. The snow flake symbol indicates cooling. 5. The sunshine symbol indicates heating. 6. The three arrows in a triangle is the automatic mode where the heat pump would choose to heat or cool the pool depending on the set temperature. 7. For pool heating in the UK keep the heat pump in the heating mode (sunshine symbol). 8. If pressing the MODE button does not change the mode and the heat pump remains in the heat mode (sunshine symbol) then the cooling and automatic modes have been deactivated. 9. If pressing the MODE button does not change the mode and the heat pump is not in the heating mode, firstly make sure you are in standby and then try again. If you can not change the mode at all refer to the troubleshooting (changing parameters) section. H. Auxiliary Mode of Your Swimming Pool Heat Pump 1. The AUX button on the heat pump is not used. 2. When pressed the AUX button may make a wavy line symbol appear and disappear on the display but no equipment is operated. I. Winterising and Maintenance of Your Swimming Pool Heat Pump 1. At all times only let swimming pool water through the heat pump which has the correct chemical balance. Chlorine not to exceed 3 ppm ph between 7.2 and 7.7 Total Alkalinity ppm Calcium Hardness ppm 2. When it is decided to close down the swimming pool for the winter it is important that the heat pump be immediately emptied of water. 3. Ensure that pool water can not freely flow out of the pool and then loosen both coupling nuts to the pipe work and withdraw the pipes from the heat pump. 4. Drain all the water from the heat pump. 5. Also empty the pipes. 6. The heat pump warranty does not cover frost damage. 7. The heat pump may be left outside all the year round but if you do have some room for the heat pump in a shed or garage, this will be a perfect place to keep it for the winter period. 8. You may wish to cover the heat pump to protect it from the worst weather conditions but do not wrap up the unit too tightly, let air circulate around it. 9. Do not lay the heat pump on its side, always store upright. HeatSeeker Swimming Pool Heat Pump: Page 7 of 10
8 J. Troubleshooting Your Swimming Pool Heat Pump: Error Codes 1. The most common problem reported is the heat pump showing a display but not running its fan and compressor. This is the time delay on start up. From pressing START/STOP there is a 2 3 minute delay before the fan and compressor start. 2. The second most common problem is insufficient flow through the heat pump indicated by EE 03. If your swimming pool filter has a multiport valve turn off the pool pump and turn the valve to recirculate, restart the pool pump and try the heat pump again. If this solves the problem make sure your sand filter is backwashed. 3. Another issue is not being able to operate the control panel at all. Look for a small padlock symbol on the display which means that the controls are locked. To release this press the up and down arrows together at the same time for about 5 seconds so that the padlock symbol disappears. 4. During the operating and defrosting process, the heat pump will yield a volume of condensed water. The condensed water from the cooling coil will drip from the bottom of the heat pump. Do not assume the condensed water is due to a fault or a leak in the heat pump. The table below shows error codes the heat pump may display Fault/Error Display Cause Action Water temperature in, sensor fault/error Water temperature out, sensor fault/error Coil 1 sensor fault/error Coil 2 sensor fault/error Ambient temperature sensor Too high difference in temperature in/out. PP 01 Sensor interrupted or short circuited Test line, sensor and socket. May have to be replaced PP 02 Sensor interrupted or short circuited Test line, sensor and socket. May have to be replaced PP 03 Sensor interrupted or short circuited Test line, sensor and socket. May have to be replaced PP 04 Sensor interrupted or short circuited Test line, sensor and socket. May have to be replaced PP 05 Sensor interrupted or short circuited Test line, sensor and socket. May have to be replaced PP 06 Water flow too low Check valves, filter pump, filter and by-pass Heating up PP 07 Water flow too low Check valves, filter pump, filter and by-pass First frost proofing run PP 08 Low out temperature Empty system of water Second frost PP 09 Low out temperature Empty system of water proofing run Function error in EE 01 Function error in print card Call technician system 1 Function error in EE 02 Input voltage too low Check main cable / system 2 electrician Flow guard error EE 03 Too small or too high flow Check pool pump, piping, by-pass and ball cocks. Check technical spec EE 04 Temperature EE 05 Water flow varying Check pool pump and fluctuations piping. Check valves, filter and by-pass Defrosting Logo Cold coil / element. None. Normal function Communication error EE 08 Communication error between control panel and control Check cable connection. Call technician HeatSeeker Swimming Pool Heat Pump: Page 8 of 10
9 K. Troubleshooting Your Swimming Pool Heat Pump: Parameter Settings 1. The heat pump has 11 control parameters from 00 to The parameters can be viewed but not changed while in operation mode. They can only be changed in stand-by mode. 3. Use the SET button to scroll through the parameters. 4. If you need to change a parameter make sure the heat pump is in standby mode. Parameter Description Range Default Setting Remarks 00 Setting of cooling temp 8 28 C 12 C For technician only 01 Setting of heat temp C To be set by user 02 Defrosting period min. 45 minutes For technician only 03 Coil temp. start 0 ~ -30 C 0 C For technician only defrosting 04 Coil temp. stop 2 30 C 13 C For technician only defrosting 05 Defrosting time 1 12 min 8 minutes For technician only 06 System number May not be changed 07 Re-start after power 0 / 1 1 = ja. For technician only failure 08 Available Modes: Cooling only= 0 Heating + cooling = For technician only Heating only= 3 09 Work method. 0 0 May not be changed 10 Setting of water temp. (auto mode ) 30 C 30 C For technician only 5. With the exception of Parameter 01 (setting the pool temperature set point) these parameters are usually only changed by a service technician. 6. Most parameters can not immediately be changed, even in standby mode. If you are sure you want to change a parameter proceed as below. 7. Before you change a parameter write down what it was set on. 8. In standby mode use the SET button to chose the parameter that needs changing. 9. Press the up and down arrows at the same time for about 5 seconds until you hear a small bleep. This unlocks the parameter to enable setting. 10. Use the up and down arrow to set the parameter to the new desired level. 11. After a few seconds the panel will revert to the standby mode with the new setting stored. 12. If you need to check the parameter setting use the SET button to display that parameter. L. Accessories The heat pump has a housing and cover plate to allow the digital control panel it to be mounted remotely if required. A 5m extension line with socket for this purpose is provided with the kit. HeatSeeker Swimming Pool Heat Pump: Page 9 of 10
10 M. Technical Information Code WBR-17.0H-A WBR-21.0H-A-S Rated Heating Capacity W BTU s/hr Input Power Heating W Running Current Heating A COP w/w Power Supply v/ph/hz 220/1/50 Number of Compressors Compressor Type Rotary Scroll Number of Fans 1 1 Input Power of Fan W Fan Rotation Speed rpm Noise Level db Water Connection inches 1½ 1½ Water Flow Rate m 3 /h Water Pressure Drop KPa L Unit Dimension W H mm L Packing Dimension W H mm Weight Net Gross kg This product is CE marked. The HeatSeeker heat pump is tested to current EN standards: EN :2001, EN :1997, EN :2001 and EN :1995.LVD: EN :2003, EN :2002. HeatSeeker Swimming Pool Heat Pump: Page 10 of 10
DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description
Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
HEAT PUMP FOR SWIMMING POOL Installation and Instruction Manual
HEAT PUMP FOR SWIMMING POOL Installation and Instruction Manual Revision 1.0 12.11.2013 Table of contents Table of contents... 2 1. Preface... 3 2. Specifications... 4 2.1 Performance data... 4 3. Installation
Heat Pump. Quick Start Guide Models: 035, 055, 075, 090, 115, 110, 120, 121, 135, 155, 156, & 175
Heat Pump Quick Start Guide Models: 035, 055, 075, 090, 115, 110, 120, 121, 135, 155, 156, & 175 For product manuals and further installation / operation procedures visit www.aquacal.com Important Read
Heat Pumps for Swimming Pools
Page 1 of 5 Heat Pumps for Swimming Pools This factsheet provides members with invaluable information about heat pumps and their use for heating swimming pool water. There is a consumer factsheet already
Aerona Air Source Heat Pumps
ADDENDUM to INSTALLATION INSTRUCTIONS for Aerona Air Source Heat Pumps DOC.87-05/05 Rev.04 March 2013 ATTENTION INSTALLERS - UPDATED INFORMATION! Your Grant Aerona Air Source Heat Pump has a number of
SWIMMING POOL HEAT PUMP (THP 55, THP 100, THP 120, THP 170) INSTALLATION AND USER GUIDE
SWIMMING POOL HEAT PUMP (THP 55, THP 100, THP 120, THP 170) INSTALLATION AND USER GUIDE i Read the instructions Contents I. Package content... 3 II. Performance and properties... 3 III. System design...
Astral Pool Heat Pump
Astral Pool Heat Pump INSTALLATION AND OPERATING INSTRUCTIONS OUTDOOR INSTALLATION ONLY AstralPool Australia Pty. Limited. A.B.N. 97 007 284 504 Melbourne: Ph: (03) 8796 8600 Fax: (03) 8796 8670 Sydney:
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
DX Series Heat Pump Genus Compliant
DX Series Heat Pump Genus Compliant INSTALLATION AND OPERATING INSTRUCTIONS OUTDOOR INSTALLATION HURLCON Manufacturing and Sales Pty. Limited. A.B.N. 97 007 284 504 Victoria: Ph: (03) 9765 9765 Fax: (03)
york air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
Dealer Sales & Service Guide
Analog Models w/thermostat or Timerstat Heat Siphon Not Starting 1 BREAKER TRIPPED - Check Breaker Box for correct size breaker Breakers: EX; Domestic model 2.25hp (20amp) 3.25hp (40amp) 5hp (50amp) check
Overheating limit control
Pahlén electric heater Maxi Heat with digital control is a compact and effective heater for swimming pools. It consists of a glassfibre reinforced polypropylene tank containing resistance-type heating
SWIMMING POOL HEAT PUMP UNITS. Installation & Instruction Manual DURA - series
SWIMMING POOL HEAT PUMP UNITS Installation & Instruction Manual DURA - series Rev. 1.12 29.07.2014 Contents SWIMMING POOL HEAT PUMP UNITS... 1! Contents... 2! 1. Preface... 3! 2. Specifications... 4! 2.1
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
User manual. 086U6297 Rev. 9 EN
User manual Atria Atria Duo Atria Duo Optimum Atria Optimum Comfort Diplomat Diplomat Duo Diplomat Duo Optimum Diplomat Duo Optimum G2 Diplomat Optimum Diplomat Optimum G2 086U6297 Rev. 9 EN Thermia Värme
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The
Installation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE
INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL
USERS GUIDE. LOGIC Combi 24, 30, 35. For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
ALL IN ONE. Heat Pump Water Heater
ALL IN ONE Heat Pump Water Heater INSTALLATION AND OPERATION INSTRUCTIONS Please read this user s manual carefully before operate the unit. www.airtradecentre.com CONTENTS A. IMPORTANT REMARKS ------------------------------------------------------------------------------------------------
REMOTE CONTROL MANUAL
REMOTE CONTROL MANUAL ENGLISH CONTENT PRECAUTIONS...1-2 USING THE REMOTE CONTROL UNIT...3 OPERATION...4-9 Thank you for purchasing our Room Air Conditioner. Before using your air-conditioner, please read
AIR CONDITIONER INSTALLATION MANUAL
INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by
WATER & POOL&FLOOR HEATERS OWNER S MANUAL. Including Installation Instructions and Warranty Information
WATER & POOL&FLOOR HEATERS OWNER S MANUAL Including Installation Instructions and Warranty Information To Suit 2.7kW HEAT PUMP POOL&FLOOR & WATER HEATERS MODELS 27ACP-407 27ACP2-22 27ACP2-407 27ACW-417
Instruction manual for Firstline FCS12000CH
Instruction manual for Firstline FCS12000CH Contents Introduction... 2 Safety Awareness... 3 Safety Awareness... 4 Name of Parts... 5 Name of Parts... 6 Remote Controller Preparation... 7 Operation of
Hot Water. Heat pump water heaters. Residential and Commercial R410a
Hot Water Heat pump water heaters Residential and Commercial R410a Heat pump technology Heat Pump Water Heating is a new idea using existing technology and is viewed as the latest generation of water heating
INSTALLATION & TECHNICAL MANUAL
The COMET Range of Boilers the ultimate solution for central heating INSTALLATION & TECHNICAL MANUAL If you require any further assistance: Telephone: 01698 820533 Fax: 01698 825697 E-mail: [email protected]
OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump
R-410A Duct Free Split System Air Conditioner and Heat Pump Product Family: DFS4(A/H)-System, DFC4(A/H)3-Outdoor, DFF4(A/H)H-Indoor Please read the operating instructions and safety precautions carefully
CEILING CASSETTE FAN COIL UNIT
CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and
Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +
MAKING MODERN LIVING POSSIBLE User Guide DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro + www.heating.danfoss.com The English language
www.inspection-for-industry.com
Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.
Heat Pump Installation, Maintenance and Service Manual
Heat Pump Installation, Maintenance and Service Manual This booklet is to be carefully read and instructions followed for efficient and trouble free operation of the Accent Swimming Pool Heat Pump 21 Atkinson
SECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
Technical data. Danfoss DHP-A
Technical data Danfoss DHP-A An air heat pump which produces both heat and hot water Can operate efficiently down to -0 C Danfoss TWS tank gives plenty of hot water quickly and with low operating costs
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS 2 This water heater must be installed (water and electrical installation), commissioned and serviced
NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS PARTS LIST Front Back FIG.5 FIG.6 1. Control panel 2. Carrying handle 3. Water tank 4. Casters
CE6500 Energy Recovery Ventilator
ADVANCED COMMERCIAL Energy Recovery Ventilator PRODUCT SPECIFICATIONS & TECHNICAL DATA Features NOMINAL CAPACITY 5500-7000 CFM CASING Double-wall cabinet White exterior paint, -gauge galvanized steel -gauge
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
PANASONIC TROUBLE SHOOTING GUIDE
A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling
Operating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM
SWIMMING POOL HEAT PUMP UNITS. Installation & Instruction Manual DURATECH - series
SWIMMING POOL HEAT PUMP UNITS Installation & Instruction Manual DURATECH - series Rev. 2.00 18.11.2009 Contents SWIMMING POOL HEAT PUMP UNITS 1 Contents 2 1. Preface 3 2. Specifications 4 2.1 Technical
OWNER S Manual PRINTED IN CANADA 10/2009
OWNER S Manual PRINTED IN CANADA 10/2009 Table of contents Introduction 2 General Safety Instructions 4 Installation Instructions Location 6 Water piping 7 Electrical 7 Bonding 8 Bonding and plumbing
Split Air Conditioner
Split nditioner plit itsplit ir onditioner Split Split Split Split Split User s WNER'S 'S ER'S For s: AWI/AWO-21HPR1 Delta AWI/AWO-25HPR1 Delta AWI/AWO-32HPR1 Delta AWI/AWO-53HPR1 Delta AWI/AWO-65HPR1
26 3213.13 Diesel Engine Driven Generators Page 1 of 6
Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at
Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0
Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view
Heat Pump Water Heater IOM Manual
Heat Pump Water Heater IOM Manual Installation Operation & Maintenance This manual is intended as an aid to qualified service personnel for proper installation, operation and maintenance of the heat pump
HP switch LP switch Discharge thermo Comp. Surface thermo
1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer
User manual. Atec. 086L0130 Rev. 1 EN
User manual Atec 086L0130 Rev. 1 EN Thermia Värme AB reserves the right to make changes to components and specifications without prior notice. 2010 Thermia Värme AB. The Swedish language is used for the
MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump
MAINTENANCE INSTRUCTIONS Thermia Robust heat pump 9 6 8 0-5 4 7 4 5 0 0 1 R e v. 3 Table of contents 1 Important information.................. 2 1.1 Product description....................... 2 1.2 General................................
NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS
RHEEM CONTINUOUS FLOW GAS HOT WATER REVISED MAY 2013 GAS 6 ENERGY RATING 1-6 PERSONS 12-54 L/MIN CAPACITY 10 YEAR WARRANTY 3 NOW 6 STAR EFFICIENT HOT WATER THAT NEVER RUNS OUT factor COMES ON STEADY, HOT
HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS
HEATING OF DOMESTIC OUTDOOR SWIMMING POOLS INTRODUCTION 1. There are no general EU regulations and standards for outdoor swimming pool heating. Local regulations in the member countries are covering most
For installation guide see reverse of book
USERS GUIDE LOGIC Combi 24, 30, 35 For installation guide see reverse of book When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance
TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C
Installation TURN OFF POWER TO THE SYSTEM AT THE MAIN POWER PANEL TO AVOID ELECTRICAL SHOCK. Installation should be carried out by an electrician or a qualified technician. 1.1 Find a Location for the
Troubleshooting Your Refrigerator
Troubleshooting Your Refrigerator With conscientious care, a refrigerator will perform for years with little or no repairs. Refrigerators are categorized according to the way frost is removed from them.
PORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
Water Priming Mode Purge air from plumbing system. How do I solve ER-3 WATER PRIME: TIPS ON FILLING SPA IMPORTANT NOTE WARNING
Water Priming Mode Purge air from plumbing system TIPS ON FILLING SPA Before filling remove spa skirt and be sure that all valves in the plumbing system are fully open to maximise the amount of air that
DUCT TYPE AIR CONDITIONER
OPERATING MANUAL OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES AIR CONDITIONER DUCT TYPE English Deutsch
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
G & F Manufacturing Swimming Pool Heat Pump
G & F Manufacturing Swimming Pool Heat Pump Owner s Installation & Operations Manual 5005001B Version 2.02 TABLE OF CONTENTS Page 2 Introduction 3 Installation 5 Location 5 Wind Tie Down 5 Water Plumbing
USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA
USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your
User manual. Solid (FR 98,),
User manual Solid (FR 98,), If these instructions are not followed during installation and service, Thermia Värme ABliability according to the applicable warranty is not binding. Thermia Värme AB retains
Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty
Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp
Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains
Drayton Programmable Room Thermostat 7 Day (5-2 Day) Models: 22083 / 22087 Power Supply: Battery / Mains Invensys Controls Europe Technical Helpline: +44 (0) 845 130 7722 www.draytoncontrols.co.uk Installation
INSTALLATION MANUAL. Address card EKAC10B
INSTALLATION MANUAL 88 44 µchiller compact 70 64 4a 4b G G0 power supply G G0 power supply 50 5 50 5 4a 4b 5a 5b 4 5a 5b Installation manual READ THIS MANUAL ATTENTIVELY BEFORE STARTING UP THE UNIT. DO
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
User manual. 086U6297 Rev. 6 EN
User manual Atria Atria Duo Atria Duo Optimum Atria Optimum Comfort Diplomat Diplomat Duo Diplomat Duo Optimum Diplomat Duo Optimum G2 Diplomat Optimum Diplomat Optimum G2 086U6297 Rev. 6 EN If these instructions
Important Safeguards
Table of Contents Important Safeguards...2 Product Layout...3 Preparing for Use...4 Air-conditioning without installation...4 Air-conditioning with installation...5 Control Panel...6 Operating from the
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2
SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with
To suit Daikin FDY "F" Series and FD "F" Series. (and other models incorporating BRC1B62/52 Remote Controller)
OPERATION MANUAL Split System Ducted Air Conditioner To suit Daikin FDY "F" Series and FD "F" Series AIR CONDITIONER A hr o C (and other models incorporating BRC1B62/52 Remote Controller) Dear Owner, Thank
HERZ-Thermal Actuators
HERZ-Thermal Actuators Data Sheet 7708-7990, Issue 1011 Dimensions in mm 1 7710 00 1 7710 01 1 7711 18 1 7710 80 1 7710 81 1 7711 80 1 7711 81 1 7990 00 1 7980 00 1 7708 11 1 7708 10 1 7708 23 1 7709 01
Geyser-R Heat pump water heater Installation manual
Geyser-R Heat pump water heater Installation manual 1 Version 2.9 SAFETY INFORMATION Please read carefully to prevent serious accidents or injury. The Geyser-R Heat Pump Water Heater must be installed
Oil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort
Heat Pump Product Brochure 2015/2016 Premier Series Hi-Wall Split Systems Everyday Comfort Everyday Innovation We design with you in mind. You ll find that Haier Heat Pump units are quiet, efficient and
SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT
Commercial Hot Water. Make a difference...
Commercial Hot Water Make a difference... heat S O L A R pumps The Company Quantum Energy Technologies The Quantum story is based on innovation and the quest to harness renewable energy to produce sustainable
Multi System. 16 SEER, Inverter System. 9,000 to 18,000 BTU/Hr. Single Split
Multi System 16 SEER, Inverter System 9,000 to 18,000 BTU/Hr Single Split 4MXW8-A 4TXM6-A March2013 42 Warnings and Cautions Warnings and Cautions. Notice that warnings and cautions appear at appropriate
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
Gree Solar Hybrid Hi Wall Inverter Air Conditioner
Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar
Air Source Heat Pump Installation and Maintenance Manual
Air Source Heat Pump Installation and Maintenance Manual Model Numbers: RC090MHXEA RC160MHXEA January 2013 www.samsungehs.co.uk Hendra - January 2013 1 The outdoor unit (boiler) Deciding on Where to Install
PORTABLE AIR CONDITIONER
PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
Owner s Manual RBC-AMS41E. Remote controller with weekly timer. Owner s Manual
Owner s Manual Remote controller with weekly timer RBC-AMS41E Owner s Manual Remote controller Mode d emploi Télécommande Bedienungsanleitung Fernbedienung Manuale di istruzioni Telecomando Manual del
Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009
Climasys Thermal Management System Schneider Electric Universal Enclosures 2009 Schneider Electric Universal Enclosures The specialist in sealed equipment What is the mission of Schneider Electric Universal
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:
OPERATING LIMITS Flows up to: m /h* Heads up to: m C Max operating pressure: bars Temperature range: - à + C Max ambient temperature: + C ND of orifices: à * m /h: parallel operation SIRIUX SINGLE AND
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer