Contents. Spare parts list...16 Electrical wiring...17 Electrical components...18 Miscellaneous / Notes Subject to change without notice DHA 250
|
|
|
- Christina Briggs
- 10 years ago
- Views:
Transcription
1
2 3 Contents General safety information...4 Applications...5 Method of operation...5 Product description...6 Casing...6 Rotor...6 Filter...6 Fan for process- and reactivation air...6 Heater for reactivation air...6 Electrical panel...6 Operation options...6 Installation...7 Installation and service access...7 Duct connection for permanent installation...7 Wet air duct out from dehumidifier...7 Reactivation air into the dehumidifier...7 Process and dry air with the dehumidifier installed in the dehumidified room...7 Process and dry air with the dehumidifier installed outside the dehumidified room...7 Duct connection for basement installation...7 Temporary installation...8 Electrical installation...8 Commissioning...9 Maintenance...10 Filter...10 Rotor...10 Electrical motors...10 Heater...10 Rotor drive belt...10 General summary of maintenance intervals...11 Transportation...11 Fault finding...12 Technical data...13 Performance chart...13 Dimensions...14 Technical data...14 Noise data...15 Symbols...15 Noise path...15 Noise data...15 Spare parts list...16 Electrical wiring...17 Electrical components...18 Miscellaneous / Notes...19
3 4 General safety information Anyone operating the DHA 250 should have access to this manual, and should be aware of the safety information. Only personnel with adequate knowledge of the dehumidifier should be allowed to operate and service it. Only personnel with authorisation for electrical installations are allowed to make repair of electrical components. Repair of electrical components should be carried out by suitable qualified personnel. The dehumidifier must not be installed in areas where explosion proof equipment is required. Disconnect the dehumidifier from the mains prior to opening any service panel. The service panels should remain closed except when serviceing is carried out. The dehumidifier can only be used for dehumidification of air at atmospheric pressure. Never use the dehumidifier without the filters as the desiccant rotor can become contaminated and lose capacity. Signs and instructions on the dehumidifier should not be removed or altered. This manual should always be accessible and kept close to the dehumidifier. All maintenance and control of the dehumidifier should be as per the specified schedule. Use only genuine spare parts. Prior to servicing the dehumidifier must be left to cool down for at least 15 minutes after operation.
4 5 Applications Dehumidifier DHA 250 is of the solid desiccant wheel type designed to dry air of atmospheric pressure. The dehumidifier can be used for drying air of up to 100 % relative humidity (RH) with temperatures from -30 ºC to +40 ºC. The applications are numerous and wide spread. Below are some examples: Controlling humidity levels in production processes. Drying of temperature sensitive products. Maintaining correct humidity in storage areas. Protection of equipment sensitive to corrosion. Controlling humidity levels in museums and archives. Drying after water damage and drying of buildings during construction. Climatic improvements in damp areas. Method of operation The dehumidifier operates with two air streams. A larger air stream to be dehumidified, and a smaller air stream to exhaust the moisture out of the desiccant rotor. Both airstreams are created by one common fan which pressurises a compartment of the dehumidifier creating two separate airstreams. The larger air volume, the process air, passes through the slowly rotating silica gel rotor. Silica gel is a hygroscopic material adsorbing water vapour direct from the air. When passing through the rotor the humidity of the air is reduced, whilst the moisture content of the rotor material increases. On exiting the rotor the dried air is introduced into the area, or the process to be dehumidified. The adsorption process works in temperatures from -30 ºC to +40 ºC. The smaller air volume, the reactivation air, adsorbs the moisture from the silica gel rotor. This reactivation air first enters a purge sector of the rotor, thus cooling down the rotor material, and simultaneously increasing the reactivation air temperature. The temperature of this preheated air is further increased by an electrical heater to a temperature of approximately +100 ºC. As the reactivation air passes through the rotor, in an opposite direction to the dry air, it will decrease the moisture content of the rotor material. The reactivation air will leave the dehumidifier as warm, wet air, which is then exhausted out from the building.
5 6 Product description The dehumidifier is designed to meet the requirements of IEC protective class IP 44: Casing The casing is fabricated from stainless steel The top of the dehumidifier has a top panel that can be removed for service access to electrical and mechanical components. All duct connections to the dehumidifier are designed for connections to standard size spiral ducts. Rotor The dehumidifier has a drying rotor fabricated from a desiccant material. The rotor has a matrix of corrugated and flat heat resistant sheets which houses the Silica Gel desiccant agent. This matrix creates a large number of axial flutes through the rotor, which together builds up an immense surface area for moisture adsorption in a small volume. The rotor is manufactured and processed to be able to withstand moisture saturated air without being damaged. This means that the rotor can be used in conjunction with a pre-cooling coil. Furthermore the rotor will not be damaged even if the fan or the heater for reactivation should fail during operation. The rotor is incombustible and non flammable. The slow rotation of the rotor is achieved by an electrical gear motor and a belt drive. The belt sits on the outer rim of the rotor and is driven by a pulley on the drive motor. An adjustable belt tension device keeps the belt in place and maintains tension to prevent belt slip. Correct operation of the drive system, and direction of rotation can be checked by opening the top panel. The centre hub of the rotor is equipped with ball bearings. The rotor shaft is made from stainless steel. The complete rotor part can easily be removed and lifted as one piece out from the casing. Filter The dehumidifier has one common filter for process- and reactivation air. Fan for process- and reactivation air The fan is a direct drive radial fan with a single phase standard motor class IP 54, ISO F. The fan is accessible for service after removing the top panel of the dehumidifier. Heater for reactivation air The reactivation heater is of the PTC-type (Positive Temperature Control), which can not be overheated, and gives the possibility of a stepless control for % of the dehumidification capacity. This is achieved by controlling the wet air volume. Electrical panel The electrical panel is located inside the dehumidifier and is accessible through the top panel. Switches and indications for operation are mounted at the front of the electrical panel. Operation options Using the operation switch on the front side of the dehumidifier, different running options can be selected: 0 Dehumidifier not in operation. 1 Dehumidifier in operation mode. MAN Dehumidifier in continuous operation. AUTO Automatic operation by remote humidistat, or other external on/off signal.
6 7 Installation Installation and service access Dehumidifier DHA 250 is designed for indoor installation. The dehumidifier should be installed horizontally. All components in the dehumidifier are accessible from the top of the unit. For inspection and service, a space of 400 mm must be left free above the dehumidifier to accommodate for servicing of filter, fan and rotor. When using a mounting plate, the dehumidifier must be put so that the rotorshaft still is horizontal and the wet air outlet is placed low. Duct connection for permanent installation The dehumidifier can be installed in the room that should be dehumidified or in a separate plant room. To obtain the best performance the outlets from the fans should be equipped with diffusors. Wet air duct out from dehumidifier The wet air from the dehumidifier should be exhausted to the outside. The duct should be as short as possible to minimise the chance of condensation of the wet air. This duct should slope down slightly to stop any condensed water from flowing back into the dehumidifier. If the wet air duct is extremely long, or must be installed sloping upwards from the dehumidifier, it should be insulated and have a drainage point (2 mm) drilled at its lowest position. A damper should be installed in the wet air duct to enable correct setting of the reactivation air volume during commissioning. The exhaust opening should have a coarse wire net. Reactivation air into the dehumidifier For reactivation of the dehumidifier an additional air volume is needed. This air enters the unit along side the process air. As an option the dehumidifier can be equipped with duct connections for entering air (2 x Ø80). One of them can be used for intake of ambient air for reactivation. The duct should be as short as possible, requires no insulation, and can slope up or down. In some installations, as an alternative, the reactivation air can be taken from the installation plant room, for this alternative no duct connection is needed. Process and dry air with the dehumidifier installed in the dehumidified room When the dehumidifier is installed in the dehumidified room it would normally take the process air directly from the room without any duct system. If the process air inlet needs to be connected to a duct system, the dehumidifier is prepared for using a plate with duct connections. The dry air outlet would normally have a duct system designed for distribution of the dry air in the building. Process and dry air with the dehumidifier installed outside the dehumidified room When the dehumidifier is installed in a separate plant room all inlet and outlet openings are usually ducted. The dehumidifier takes the process air as ambient air, or as pre-treated air (cooled/heated), or alternatively as return air from the dehumidified room. The dry air from the dehumidifier can be connected for post treatment or ducted back to the dehumidified room. Dampers should be installed in the dry and wet air ducts, enabling correct commissioning of the air volumes.
7 8 Duct connection for basement installation If the dehumidifier should be installed in the basement it is sometimes desirable to achieve a slight negative pressure in the basement to prevent odours from penetrating up into the building. In these circumstances the reactivation air is taken directly from the basement and the wet air is exhausted out from the basement. This method of installation will create a small negative pressure. The other ducts should be installed according to Duct connection for permanent installation. Temporary installation With temporary installations for water damage or building drying, flexible plastic ducts would normally be used instead of the spiral duct type. The drying method differs depending on situation and construction to be dried. The complete room could be dehumidified, or just the damaged part. For the later option plastic sheet is used to cover the damaged area, and the dry air is supplied under the sheet. For both options the wet air must be exhausted out from the building via flexible duct, or alternatively connected to the general exhaust ventilation system for the building. Electrical installation See the electrical wiring diagram on page 17.
8 9 Commissioning On initial start up, the following steps should be taken in this order: 1. Ensure that the external isolation switch is isolating the unit from the mains, or that the power plug is disconnected. 2. Select the OFF position on the main switch (orange) at the front of the dehumidifier. 3. Open the service panel on the top of the dehumidifier and ensure no foreign objects are left inside the unit or in the electrical compartment 4. Make sure the air filter is installed. 5. Rotate the fan impeller by hand and make sure it can move freely. 6. Ensure that the dry and wet air dampers are open, and that ducts are clean and free of blockages. 7. Ensure that the mains supply fuse is suitably rated (10A), and that the fuse is of a slow kind. 9. Connect the dehumidifier to the main electrical supply by turning the isolation switch to ON, or alternatively connect the power plug to the socket. 10. Select the MAN position on the operation switch (black) of the dehumidifier. Switch the main switch (orange) to the ON position for 3-4 seconds. Check that the rotor is slowly rotating, the fans are starting, and that the orange lamp in the main switch lights up. Turn OFF the dehumidifier. 11. Mount the service panel and ensure it seals properly to the casing. 12. The dehumidifier is now ready for operation. 13. Start the dehumidifier and check that the unit is operating at the correct air volumes. An indication of correct operation is if the ampere meter on the front of the dehumidifier indicates approximately 6 A. 14. From the factory the dehumidifier is electrically wired in such a way that when operating in AUTO mode, the controls operate the complete unit to start or stop. By shifting one terminal connection in the electrical panel the operation mode can be altered to operate the fan continuously. The control will then only operate the heater on /off, depending on the signal from the humidistat or other external signal. See the electrical wiring diagram on page 17.
9 10 Maintenance NOTE! With all maintenance and service of the dehumidifier: Switch off the dehumidifier approximately 15 minutes prior to opening the service panel, allowing the heater to cool down. Disconnect the dehumidifier from main electrical supply by turning the external switch to the off position or by pulling out the power plug. The maintenance intervals for the dehumidifier depend on the surrounding environment and installation site. Recommended maintenance intervals could therefore differ from one installation to another. Incorrect maintenance and service may result in reduced dehumidification capacity. Filter The dehumidifier is equipped with one common filter for the process air and reactivation air. The filter is positioned at the inlet and will clean the air prior to entering the dehumidifier. Intervals for cleaning or replacement of the filters will be determined by the amount of dust and particles in the air at the installation site. We recommend that the filter is checked at least once a month, at least for the first year of a new installation. Never operate the dehumidifier without the filter, as the rotor can be damaged by dust. Electrical motors The electrical motors are equipped with ball bearings. The bearings are designed to last the life of the motor and therefore no maintenance is required. Check the motors once a year for any abnormal sound. Heater The reactivation electric heater does not need maintenance, but should be checked twice a year for any dust or mechanical damage to the heating rods. Clean with a soft brush, or vacuum clean with dust. Gentle use of compressed air is another alternative. Rotor drive belt Check the belt tensioning at regular intervals. Adjust when needed by moving the tensioning support wheel closer to the desiccant rotor. Rotor The rotor is maintenance free. However should it be necessary to clean the rotor careful use of compressed air should be the first choice. With severe contamination the rotor can be washed with water. Cleaning with water is no routine matter, please contact distributor prior to this procedure. Check the rotor bearing and the rotor surface once a year.
10 11 General summary of maintenance intervals Filter Rotor Bearing Motors Rotor drive Heater Sealings On demand Every 6th month Every 12th month Transportation Observe the following for transport or handling of the dehumidifier: Check the dehumidifier on delivery for any transport damage. The dehumidifier should be protected from rain and snow. The dehumidifier should always stand upright on its feet. Transport and lift the dehumidifier by the two handles on each side of the transportation box.
11 12 Fault finding Malfunction Possible cause of trouble Corrective action None, or reduced dehumidification Filter clogged Clean or replace filters capacity Electrical heater faulty Check fuses Main fuse faulty Dehumidifier does not start Rotor does not rotate No dry- or wet air volume Airflow reduced No rotation of rotor Internal leakage in unit Altered air volumes Altered reactivation temperature Air leakage Fan faulty Too large air volume Rotor does not rotate Reactivation heater faulty No control circuit Faulty control signal Fuse for controls faulty Drive belt is slipping Drive belt broken or worn Rotor jammed Drive motor faulty Filter clogged Fan faulty Ducts blocked Check openings and dampers Check belt tensioning Check springs Measure and check air volumes Check reactivation heater Check panel and casing Check fan and motors Check air volumes and dampers Check drive motor and drive belt Check reactivation heater Check control fuses Check external start/stop signal Check electrical components Check belt tensioning Replace drive belt Check centre shaft, rim of rotor Replace complete gear motor Clean or replace filters Check fan, motor and impeller Check dampers and ducts
12 13 Technical data Performance chart 20 CAPACITY DIAGRAM 20 X T (g/kg) 15 t p =30 C 15 Temperature rise ( o C) t p =20 C 5 5 t p 10 C X P (g/kg) EXAMPLE: Process air: x p = 9,0 g/kg, t p = +20 C giving Dry air: x T = 6,1 g/kg, t T = 20+8,5 = 28,5 C 0
13 14 Dimensions Technical data Dehumidification capacity 1,1 kg/h (at +20 ºC and 60 % RH. See performance chart for other data) Dry air flow (freeblowing) Wet air flow (freeblowing) Power supply (1 x 230 V, 50 Hz) Current (connection fuse: 10 A) Weight Noise level 290 m3/h 80 m3/h 1,4 kw 6,1 A 18 kg 61 db(a)
14 15 Noise data Noise path A Open intake for process air. B Open intake for process air. Dry air outlet ducted and air discharged at 2-3 m above floor. C Ducted outlet for dry air. Wet air outlet ducted with short 90 degree angle duct. D Only dry air and wet air outlet ducted. Noise data E All outlets completely ducted. Correction of K db at ISO-band No/Centre frequency (Hz) Noise path LWA 1/64 2/125 3/250 4/500 5/1000 6/2000 7/4000 8/8000 A B C D E Symbols L WA = Total noise level in db(a) (rel W) L WAO = Noise power level in octave band db(a) (rel W) K = Correction for calculation of LWAO (L WAO = L WA + K) db(a) = Noise power level at room condition R = 10 2 Sab
15 16 Spare parts list Part Technical specification No installed No of recommended spare parts Drive motor Gearmotor V 50 Hz 3 rpm low temp grease Belt pulley HTD 5M, Z=20 1 Drive belt M-9 1 Fan G2E 160-AS Capacitor 4 µf 400 V Heater PTC HR-AB PH2PA V 1 1 Wet air duct Heat resistant flexcord Ø80 1 Rotor PPS Belt tensioning 1 Filter AAF R29 EN779:G3 220 x 330 mm 1 3 Toggle switch 2x1 pol. electric switch 1 Ampere meter RQ48E 10A IP 54 1 Cord H07RNF/3 x 1,5 1 Process air duct connection Comment 2 x Ø80 0 Option
16 17 Electrical wiring 230 V 50 Hz 1,4 kw S1 S2 P M1 2 Black C 6 4 M A 4 h Optional operation method when controlled by humidistat If continuous operation of the fan is requested, and the humidistat HS should control only the reactivation heater, shift wire 2-2 from terminal P1:2 to terminal P1:1 Humidistat Connect humidistat to terminal P3:8-9 P E P2 Brown Blue Yellow / Green Name Component S1/S2 On-Off / Man-Auto switch h Runtime meter * HS Humidistat * A Amperemeter P1 Terminal block 7-pin E React. heater M1 Drive motor, rotor C Capacitor P2 Terminal block 4-pin P3 Terminal for humidistat M2 Fan *) Optional
17 18 Electrical components No Part Mark Type Quantity Manufacturer 1 Gear motor 230 V, 50 Hz, 3 rpm M BJ 1 Crouzet AB 2 Radial fan, G2E 160-AS M2 EK259 1 ZIEHL-ebm AB 3 Capacitor, 4 µf 400 V C KO218 1 ZIEHL-ebm AB 4 Toggle switch 2x1-pol. bl/or S1/S Orbitus Ind.komp. 5 Amperemeter A RQ48E 10A IP54 1 Tälje mätinstrum. 6 Heater, 230 V E PH2PA Victon Ltd. 7 Terminal male 7-pin P1 sls 5.08/7B sn or 1 Weidmüller AB 8 Terminal, female 7-pin P1 blz 5.08/7 sn or 1 Weidmüller AB 9 Terminal male 4-pin P2 sls 5.08/4B sn or 1 Weidmüller AB 10 Terminal female 4-pin P2 sls 5.08/4 sn or 1 Weidmüller AB 11 Blind panel, 48 x Tälje mätinstrum. 12 Blind plug, 22,0-25,5 mm - P208/4 1 OEM Component 13 Cord, H07RNF/3G1.5/3,5m OEM Component 14 Runtime meter h * 15 Humidistat plug connection HS * *) Option
DEHUMIDIFIER DehuTech 450
DEHUMIDIFIER DehuTech 450 Technical Manual Valid from serial no: 030311 2002 DehuTech AB EC-declaration of conformity Fuktkontroll AB Enhagsslingan 23 187 40 TÄBY Sweden declare under own responsibility
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan
Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR
USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR CONTENTS Introduction Safety Notes Identification of parts Installation instructions Operation instructions Maintenance Troubleshooting
USER S MANUAL HSC-24A
AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL
Meaco 30L and Meaco 40L dehumidifier instruction manual
Meaco 30L and Meaco 40L dehumidifier instruction manual Please read this instruction manual before using the dehumidifier and keep safe for future reference SAFETY INSTRUCTIONS PLEASE READ ALL INSTRUCTIONS
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102
USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102 THANK YOU FOR CHOOSING YOUR NEW DEHUMIDIFIER. BEFORE USING THE UNIT READ THESE INSTRUCTIONS FULLY AND RETAIN THEM FOR FUTURE REFERENCE
Owner s Manual Phoenix 1200 Desiccant Dehumidifier
4201 Lien Rd. Madison, WI 53704 Owner s Manual Phoenix 1200 Desiccant Dehumidifier Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix 1200 Portable Desiccant Dehumidifier
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W
MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Dehumidifier D 850E. - Instruction manual version 02
Dehumidifier D 850E - Instruction manual version 02 Content 1. Description of dehumidifier 1.1. General data 1.2. Technical data 2. Operation and usage 2.1. Usage 2.2. Location and installation 2.3. Preparing
Dehumidifier Users manual. For Models: DH45S DH65S
Dehumidifier Users manual For Models: DH45S DH65S 950-0062-revD Jan. 9 2007 FORWARD The appearance of the units that you purchase might be slightly different from the ones described in the Manual, but
Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.
Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support
BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL
BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL Drawing : - TPC337 Issue : - 2 Date : - 24/01/12 UNPACKING Thank you for deciding to purchase an EIPL Industrial dehumidifier. Like the many tens of thousands
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW
Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MN12CES / MN10CESWW Voltage rating: 120V~60Hz Power rating : 1100W (MN12CES) Power rating : 900W (MN10CESWW) Customer
Use and Care Manual. Model CPA12KH AIR CONDITIONER
Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage
Installation and maintenance instructions. Danfoss Vent
Installation and maintenance instructions Danfoss Vent 1 Unit design... 2 2 Project planning and installation instructions... 3 2.1 Ventilation...3 2.2 Piping installation....3 2.3 Condensation line...4
Installation, operation and maintenance manual TX 35A
Installation, operation and maintenance manual TX 35A Rev.10 may 2012 Page 1 of 18 1.0.0 Table of contents INSTALLATION, OPERATION AND MAINTENANCE MANUAL...1 1.0.0 TABLE OF CONTENTS...2 2.0.0 ILLUSTRATIONS...2
Split Type Room Air Conditioner. KSWM units
OWNER S MANUAL Split Type Room Air Conditioner KSWM units Please read the operating instructions and safety precautions carefully and thoroughly before installing and operating your room air conditioner.
Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS
Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477
Single-Phase AC Synchronous Generator
ST Series Single-Phase AC Synchronous Generator Instructions for Operation and Maintenance English to English translation by R.G. Keen, May 2004. ST Series of Single-Phase AC Synchronous Generators Description
FOXAIR 60/50 ALL MODELS
FOXAIR 60/50 ALL MODELS OPERATION AND SERVICE MANUAL UNIT WEIGHT - ALL MODELS APPROX. 300 POUNDS FOXTRONICS, INC. 38 L x 28 W x 24 H Love Field-Dallas TX MADE IN THE USA 3448 West Mockingbird Lane Dallas,
PORTABLE AIR CONDITIONER
VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner
GenStore Archive Cabinet
GenStore Archive Cabinet Setup and Maintenance Manual Version A April 2014 Two GenStore Archives shown mounted on optional table stand. 2 Contents Getting Started... 4 Using this Manual...4 Safety Precautions...4
SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit
SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS
OPTIONAL SLENDER REMOTE CONTROL
DAIKIN ROOM AIR CONDITIONER Operation Manual OPTIONAL SLENDER REMOTE CONTROL BRC944A2B READ BEFORE OPERATION Safety Precautions...2 Names of Functions of Parts...4 Preparation before Operation...5 OPERATION
Fire Protection Notice No. 9 ELECTRICAL SAFETY
Fire Protection Notice No. 9 ELECTRICAL SAFETY Because electricity is one of the most controllable forms of energy it can also be one of the safest. But, as industry and commerce draw ever more heavily
REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)
SA Port Operations DOCUMENT TYPE: REFERENCE EEAM-Q-014 (ORIGINAL SPECIFICATION HE8.2.3 Ver5) REVISION 0 SPECIFICATION TITLE: SPECIFICATION FOR ELECTRICAL MOTORS AND GENERATORS PAGE 0 of 07 COMPILED BY
Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed
Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed Rely on GD to provide the perfect fit The perfect fit to maximise productivity The growing industrial demand for compressed air requires
USER S, MAINTENANCE and SERVICE INFORMATION MANUAL
CONTENTS SAFETY INFORMATION................ 2 FOR YOUR SAFETY....................... 2 SYSTEM OPERATION.................. 2 THERMOSTATS........................... 2 INTERMITTENT IGNITION DEVICE...........
CARING FOR YOUR WATER HEATER
http://waterheatertimer.org/troubleshoot-rheem-tankless-water-heater.html Water Heater Inspections CARING FOR YOUR WATER HEATER Venting System (Direct Vent Only) The venting system should be inspected
V94 BULK TAPE DEGAUSSER
TECHNICAL MANUAL Operating and Maintenance Instructions for V94 BULK TAPE DEGAUSSER V94 BULK TAPE DEGAUSSER TECHNICAL MANUAL Document No. M000208 Production Standard ZZ 009 415 WARNING To help minimise
REGULINE 600VA / 1000VA REGULATOR USER MANUAL
REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS
SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER
SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC
SPLIT-TYPE AIR CONDITIONERS Revision B: MUZ-EF25/35/42/50VE - E2 and MUZ-EF25/35VEH - E2 have been added. Please void OBH590 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH590 REVISED
SWIMMING POOL AIR-HANDLING UNITS KU-DB Series
SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =
Owner s Manual Phoenix D385
PO Box 8680 Madison, WI 53708 Phoenix D385 TS-387 Owner s Manual Phoenix D385 Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix D385 provides the perfect combination
Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI
Pocket Manual Service Diagnosis SPLIT & MULTI Service Diagnosis SPLIT & MULTI 1. Troubleshooting with LED...5 1.1 Indoor Unit... 5 1.2 Outdoor Unit... 10 2. Troubleshooting by Symptoms...11 2.1 Air conditioner
TIG INVERTER INSTRUCTION MANUAL
TIG INVERTER INSTRUCTION MANUAL Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4
Operating Instructions Split System Air Conditioner
Operating Instructions Split System Air Conditioner Model No. Indoor Unit Type Indoor Unit Type Nominal Capacity 26 36 F2 Low Silhouette Ducted S-26PF2U6 S-36PF2U6 Connectable outdoor unit lineup This
INDOOR UNIT/OUTDOOR UNIT
SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT MODEL RAS-60YHA/RAC-60YHA OUTDOOR UNIT INDOOR UNIT RAC-60YHA RAS-60YHA Instruction manual Page 1~26 To obtain the best performance and ensure years of
AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T
Product Instruction Manual Accona AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T Panel heater v16.5/5 Version 3.2 Jan 2015 Contents 1. Important safety points 2. Installation 2.1. Wall mounting
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug
ALL IN ONE. Heat Pump Water Heater
ALL IN ONE Heat Pump Water Heater INSTALLATION AND OPERATION INSTRUCTIONS Please read this user s manual carefully before operate the unit. www.airtradecentre.com CONTENTS A. IMPORTANT REMARKS ------------------------------------------------------------------------------------------------
Failure code manual. content
Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一
How To Use A Power Supply Unit (Upu)
BRAVER UPS (Uninterruptible Power System) User s Manual Safety CAUTION! This UPS utilizes voltages that may be hazardous. Do not attempt to disassemble the unit. The unit contains no user replaceable parts.
WINDOW ROOM AIR CONDITIONER
WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please
Split Air Conditioner
Split nditioner plit itsplit ir onditioner Split Split Split Split Split User s WNER'S 'S ER'S For s: AWI/AWO-21HPR1 Delta AWI/AWO-25HPR1 Delta AWI/AWO-32HPR1 Delta AWI/AWO-53HPR1 Delta AWI/AWO-65HPR1
SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)
SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT) MAINTENANCE TYPE: STATUTORY 1.0 SCOPE OF SERVICES The Contractor shall provide maintenance Services for
OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex
OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex Version C Single, Dual, Tri or Quad Zone Ductless Mini-Split System Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS BEFORE USE GENERAL SAFETY INSTRUCTIONS: ALWAYS OPERATE THE UNIT IN AN UPRIGHT POSITION AND PLACE
Adsorption air dryers ADS 1 215
Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that
A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.
A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities. Richard L. Dornfeld, BSME, P.E. Staff Engineer September 25, 2014 Moisture can be a problem
Operating Instructions Air Conditioner
F566272 Operating Instructions Air Conditioner CS-C18FFH CS-C28FFH CU-C18FFH CU-C28FFH ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand
9041381- Issue 6 4/11 MODEL: DV72 Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual Commissioning Data: to be completed by the installer Date of installation: Configuration
A/C-HEATER SYSTEM - AUTOMATIC
A/C-HEATER SYSTEM - AUTOMATIC 1995 Volvo 850 1995-96 Auto. A/C-Heater Systems Volvo 850 * PLEASE READ THIS FIRST * WARNING: To avoid injury from accidental air bag deployment, read and carefully follow
BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION
Air Conditioning Central Heating & Cooling BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION INSTALLATION AND SERVICE MANUAL 2 PROJECT: ADDRESS: MODEL: SERIAL NUMBER: INSTALLER: ADDRESS: PHONE NUMBER: INSTALLATION
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER
INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER The instructions that follow are to assist you in completing the information required when making a fan or blower selection. If you need additional
ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.
ROOFTOP - HEAT PUMP UNIT Technical data Applies to Model YNRA R410A This document applies when installing into an air handler or as part of an air handling system. CONTENTS 1. General description... 2
Meaco DD8L desiccant dehumidifier Instruction Manual
Meaco DD8L desiccant dehumidifier Instruction Manual Meaco DD8L Desiccant Dehumidifier January 2013 edition Please read this instruction manual before using the dehumidifier and keep safe for future reference.
SWIMMING POOL HEAT PUMP Owners Manual
SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor
INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR
INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR INTRODUCTION The Cirro MK 3 is a fully professional mist generator for producing sufficient airborne reflection particles to enable effect lighting to
SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL
SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL Thank you for choosing our Air Conditioner. Please read this OWNER'S MANUAL carefully prior to use and keep it for further reference. CONTENTS Contents
Cooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
543-0032-00, 943-0032-00. User s Manual
543-0032-00, 943-0032-00 User s Manual 1 Comfort Alert Diagnostics Faster Service And Improved Accuracy The Comfort Alert diagnostics module is a breakthrough innovation for troubleshooting heat pump and
SWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
Table Z. Troubleshooting Chart for Air Conditioners. Cause
Troubleshooting Chart for Air Conditioners Type of Unit Complaint Cause With open-type compressor Electric motor will not start Power failure Check circuit for power source Compressor stuck Locate cause
2KW CERAMIC HEATER DHCER20. User Manual
2KW CERAMIC HEATER DHCER20 User Manual Please read the instructions carefully before using the product and keep this user manual for future reference. 1. PRODUCT FEATURES 2kW heat output Choice of heat
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
Technical Specification for Model RSK2503 (Z)-06A IR Belt Solar Cell Firing Furnace
Technical Specification for Model RSK2503 (Z)-06A IR Belt Solar Cell Firing Furnace TECHNICAL SPECIFICATION Model RSK 2503(Z)-06A IR Belt Solar Cell Firing Furnace Temperature Range 1. Max Temperature.
USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB98-29565A(1) ENGLISH ESPAÑOL
USER S MANUAL Duct Type Series MH MH FEEA Series FUEA Series ENGLISH ESPAÑOL PORTUGUÊS E HNIKA DEUTSCH ITALIANO FRANÇAIS Free Joint Multi Air Conditioner (Cooling and Heating) E S F I P D G DB98-29565A(1)
TFSR & TFSK Roof Fans
Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans TFSR & TFSK Roof Fans With swing-out function 2 I TFSR/TFSK TFSR & TFSK Roof
IH 17025 E Sigma Island 90
INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood
OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)
OPERATION MANUAL (Ceiling mounted duct type) VAM50FB VAM500FB VAM650FB VAM800FB VAM000FB VAM500FB VAM000FB 8 7 6 9 5 7 5 0 6 8 6 9 0 5 5 7 7 6 7 A A B B 5 6 5 6 7 VAM50F VAM800F VAM500F VAM500F VAM000F
Why is my air conditioner dripping on my customers?
De-Mystifying HVAC Why is my air conditioner dripping on my customers? By Ron Prager One of the most frequent emergency service requests is a call for an air conditioner leaking water into the store. These
Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.
EGLISH 1 Product description exchanger equipped with an electronic control unit and circulation pump for the primary circuit. All Aqua-Mex variants can be ordered with an interior coil of either titanium
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS
ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...
Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC
Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with
Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06
A/C Performance Diagnosis Problem Warm Airflow When the Air Conditioner is On, A/C Not Working, or Poor A/C Performance (dash outlet temperature is too high) Problem Warm Airflow When the Air Conditioner
SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2
SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with
Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump
Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum
www.inspection-for-industry.com
Quality Control Form (TEST RUNNING RECORD FOR AIR HANDLING UNIT) SUB POWER SUPPLY: MAIN POWER V, Hz, CONTROL V, Blower 1 kw, Blower 2 kw, Compressor: (1) kw (2) kw (3) kw (4) kw Heating Element: kw 1.
Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF
Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems
Universal Split Systems If there is a fault on any LG Universal unit, a two digit number will appear on the remote controllers led display. If the unit does not have a remote controller the fault will
Vertical Display and Storage B1350-2. SKOPE Gen2: Three Door Chiller
Vertical Display and Storage User Manual MAN1227 Rev. 3.0 March 2008 edition CONTACT ADDRESSES Designed and Manufactured by New Zealand SKOPE INDUSTRIES LIMITED PO Box 1091, Christchurch New Zealand Freephone:
HVAC Design Requirements
Maintenance of HVAC HVAC Design Requirements Air Flow Diagram แบบ Recirculation Air Flow Diagram แบบ Once Through Definition Of Conditions As built At rest In operation air air air Maintenance GMP Requirements
HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)
HVAC SYSTEM (HEATER, VENTILATOR, AND A/C) HEATER SYSTEM 1. Heater System A: GENERAL A semi-center type integrated air conditioning unit is used, where a high performance heater core and an evaporator core
SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1
SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH
Air Conditioner Water Heater - A Product of HotSpot Energy LLC
Air Conditioner Water Heater - A Product of HotSpot Energy LLC PLEASE READ THIS BEFORE YOU INSTALL THE UNIT 1. This air conditioner must be installed and/or repaired by a qualified technician. If you perform
M A N U A L 13-10-05
Documentation The following information sheets illustrate the description below: 12-WW01-4G-E Sectional view of the lance with main dimensions 12-W101-6G-E Sectional view of the head of the lance with
SINGLE PHASE MOTORS. INSTALLATION AND MAINTENANCE MANUAL March 21, 2006
SINGLE PHASE MOTORS INSTALLATION AND MAINTENANCE MANUAL March 21, 2006 Irvine, California (800) 474-0520 Indianapolis, Indiana (800) 866-7973 Hamilton, Ontario (800) 809-0330 e-mail: [email protected]
Match. GE Digital Energy. Uninterruptible Power Supply 500-1500 VA. Technology for the Digital World. Match UPS. GE Digital Energy.
Match Uninterruptible Power Supply 500-1500 VA Manufactured by: General Electric Company Telephone +41 (0)91 / 850 51 51 CH 6595 Riazzino (Locarno) Fax +41 (0)91 / 850 51 44 Switzerland Website www.gedigitalenergy.com
Oil-Free Screw Compressors. Water-injected Technology. Rely on GD to provide the perfect fit
Oil-Free Screw Compressors Water-injected Technology Rely on GD to provide the perfect fit Why oil-free? Don t compromise on quality If 100% clean and oil-free compressed air is a requirement for your
Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0
Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view
Taurus Series YORK Window Air Conditioners
Taurus Series YORK Window Air Conditioners IOM IOWRCAG50220711A1 Warning 1. Before using the Air conditioner please read the instructions carefully. They contain important advise about the installation,
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI
INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI Page 2 / 16 CONTENTS 1 GENERAL... 3 2 SAFETY... 3 2.1 Safety instructions... 3 2.2 Correct use... 3 3 DESCRIPTION
Digi-Motor Installation Guide
Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support