GROUNDING & BONDING. Pool & Spa Solutions

Similar documents
SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Washer, Electrical Equipment Bond WEEB

CDGRD-10. Grounding. Solutions For Comm/Data Applications

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

CT-02 CABLE TRAY SYSTEMS

This presentation to be used in conjunction with:

18 AWG thru 8 AWG Not greater than 100/30 100/30. 6 AWG thru 1/0 AWG Not greater than 200/60 100/30

Washer, Electrical Equipment Bond. WEEB Patent Pending INSTALLATION INSTRUCTIONS. For Kinetic Solar K-Rack only

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Section Grounding and Bonding for Communications

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

Please check with your local inspection authority for any additional requirements before installation.

TC Grounding and Bonding for Telecommunications Systems

(3) The requirements of this Section are supplementary to, or amendatory of, the general requirements of this Code.

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

James M. Pleasants Company

STREETLIGHT SYSTEM GROUNDING AND BONDING

INSTALLATION & OPERATING INSTRUCTIONS

V47 Series Temperature Actuated Modulating Water Valves

POOL AND SPA REQUIREMENTS

AMERBRITE UNDERWATER WHITE LED POOL LAMP

White Paper SolarEdge Three Phase Inverter System Design and the National Electrical Code. June 2015 Revision 1.5

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

Charter Township of Shelby Harry Reese Building Director

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

SWIMMING POOLS CHAPTER 41

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

SPECIFICATIONS FOR TENDER NO: PSNR/SCP/VKS/E 1635 ANNEXURE I TECHNICAL SPECIFICATIONS FOR LIGHTING HIGH MAST

ONTRAC WIRE MESH CABLE TRAY SYSTEM

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

I-Line. Accessories. Essential cable installation products for corrugated, smooth wall, and braided cables

Electrical Service Guidelines

3M Mobile SkyWalk Series Horizontal Lifeline Product Return Form

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

RAY-MAX Integrated Solar Power Strip

PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS

Requirements for Electrical Installations

Item No. Name of Part Item No. Name of Part Item No. Name of Part

HELIPORT FUEL/WATER SEPARATOR MODEL H-200

RE-ENTERABLE SPLICE CLOSURE KITS. (For Air Core None Pressurized Cable)

GUE, GUB Junction Boxes

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

Carlon Expansion Fittings for PVC Rigid Nonmetallic Conduit

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Instruction / Installation Sheet DataComm Electronics WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Power Solution

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

SSNICLRG SSNICSM PLNICLRG PLNICSM

Corrosion Control & Cathodic Protection for Water & Wastewater Systems

GUIDELINES FOR INSTALLATION OF AIR CONDITIONING UNITS PHILLIP STREET, SYDNEY

Horizontal Jet Pumps 1/3-1-1/2 HP

800 Communications Circuits

Cable Accessories. for Extruded Dielectric Cable 69kV - 230kV Rated. Catalog Python13

Select Radiators Installation Guide

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

RAIL FREE SOLAR ROOF MOUNT

Heating Cable. Construction

POWERS Controls No. 4 Pneumatic Damper Actuator

Mini USB and USB 2.0-IP67 Connector System

Color Splash LED Light Fixture Installation and Operation Guide

Type 1, 3, & 3R Enclosures

Cooling Capacity CFM in. w.c. (125 Pa)

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Packaged Terminal Air Conditioner Wall Sleeve Installation

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

HEAT WAVE DUCT KIT KIT #

Solar Power System Installation Manual

SWIM N DUNK CHALLENGE RESIDENTIAL BASKETBALL GAMES And COMMERCIAL ASSEMBLY AND INSTALLATION INSTRUCTIONS

Residential Deck Safety, Construction, and Repair

Generator DoCKInG StatIonS

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

SWIMMING POOLS, SPAS AND HOT TUBS Section AG101 General.

SECTION CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

400 Series - Mini USB Buccaneer

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

Installing a new 928 Motorsports All-Aluminum Radiator

SECTION WINDOW WASHING SYSTEMS

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Andersen Electric Window Opener for Andersen Awning and Roof Windows

GENERAL ELECTRICAL REQUIREMENTS

Solar Power Solutions

Terminal Boxes Series 8146

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES

Operators manual Basic water heater

PRESSURE AND TEMPERATURE SENSORS for use with the BURNERLOGIX Burner Management System and PPC4000 Series Fuel/Air Ratio Controller

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES

Installation Instructions Hustler 6-BTV Trap Vertical

Dock Hardware & Accessory Products Catalog

MA BUILDING CODES ON SWIMMING POOLS SECTION 780 CMR 120.M

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

Chapter 9. Bonding and Grounding

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Grounding & Bonding Why it is done And How to Install Properly

Transcription:

GROUNDING & BONDING Pool & Spa Solutions

Relax. With BURNDY, You re Grounded. Before millions of Americans can escape the heat with a dip in a cool pool or warm up in a muscle-soothing hot tub, there s a lot that goes into ensuring these recreational staples are as relaxing and safe for you and your customer as possible. BURNDY offers a complete line of grounding connectors for the pool and spa market: lay-in lugs, ground mesh, ground connectors for rebar, ground lugs and water bonding kits. Working together, we can ensure the success of vacation days no matter the weather around us. About Us With corporate headquarters in Manchester, New Hampshire, BURNDY employs more than,00 employees, including more than 5 BURNDY Factory Direct Sales Representatives and top manufacturing representatives. We staff manufacturing sites throughout New England, the American Midwest and Canada, plus a distribution center in New Hampshire. As a global company, we have offices in Mexico, Brazil and Canada in addition to our engineering and marketing business units in India. We also have 0 fully equipped demonstration trucks in the United States, Canada and Mexico. Whether you re looking for information about the products you plan to install or how existing products are performing, we have the solutions you need.

Products for Pool & Spa Applications Product Split Bolts* Copper Wire Grid ( )* Lay-in Lug* Wire to Rebar* Wire Terminal* Water Bonding Kit *Suitable for direct burial Purpose Connect to rebar or to the Equipotential bonding Bonds metal components Bonding to rebar Bonding of motor and equipment Maintain constant contact with pool water Catalog Number KS CL50- KPB4CG CK6D CK7D GKA4C BWB680 BURNDY The BURNDY Equipotential Bonding Grid is made of prefabricated wire mesh and manufactured from bare solid copper. Starting from this base, the grid can be customized with: 4-, 6- or -inch centers Lengths from 4 to 00 feet Sizes are made specifically for the pool and spa market (from feet by 00 feet, and feet by 50 feet), and meets NEC article 680.6(C). The grid is easily and economically installed using BURNDY HYGROUND compression grounding, BURNDY mechanical connectors or BURNDYWeld exothermic. HYGROUND Compression Grounding HYGROUND meets the most stringent safety and performance requirements, including UL96, UL467, CSA and IEEE87, and is approved for direct burial. All HYGROUND connectors can be installed in any type of weather in less than three minutes. The HYGROUND system is known for its top quality and long-term performance. meets NEC article 680.6(C) Equipotential Bonding Grid. The parts specified in 680.6(B) shall be connected to an equipotential bonding grid with a solid copper conductor 680.6(C)()(b) Grid Structure. The equipotential bonding grid shall cover the contour of the pool and the pool deck extending m ( ft.) horizontally from the inside walls of the pool. The equipotential bonding grid shall be arranged in a 00mm ( in.) by 00mm ( in.) network of conductors in a uniformly spaced perpendicular grid pattern with tolerance of 00mm (4 in.) The NEC requires that electrical equipment shall be grounded The following equipment shall be grounded All electrical equipment located within.5 m (5ft) of the inside wall of the specified body of water. (Article 680.6) This equipment also includes drain, rebar, water inlet, skimmer, ladder, slides, diving structure, underwater lighting, junction boxes, and water circulating/heating equipment. Using BURNDY Grounding products assures you will meet the applicable NEC requirements.

Mechanical Connectors Lay-In Lugs The lay-in-lug style makes it easy to ground the conductor to a pool s steel frame or in other continuous-run applications. CL50- This copper lay-in lug accepts 4 4 AWG with a #0 stud. The CL50 is UL Listed and CSA Certified. KPB4CGRK Accommodates #0 4 copper wire where continuous conductor runs are preferable. The KPB4CGRK is UL486 and UL467 listed for direct burial in earth and concrete. Wire to Rebar Connectors BURNDY wire-to-rebar connectors have an open-face design to make it easy to lay in to the tap conductor. CK6D and CK7D These cast bronze ground clamps fit ½- to -inch water pipes, and are compatible with #4 6 rebar and 0 AWG AWG. Wire Terminal BURNDY offers a range-taking terminal for grounding outdoor equipment, such as motors, ladders, slides and lighting. GKA4C Made of copper alloy, this wire terminal accepts 4 AWG 4 AWG and is ROHS compatible. Pool Water Bonding Kit BWB680 Series In compliance with NEC 680.6(C), the BURNDY BWB680 series maintains constant contact with pool water to ensure that the pool is effectively bonded at all times. Unlike other products, the BURNDY BWB680 is placed in the pool s skimmer, ensuring it is always in contact with the water. Made of non-corrosive stainless steel, the BWB680 kit: Is easy to install on the side wall of the skimmer, below the basket and out of the way Includes one bonding plate, a rubber sealing washer, two flat washers, two lock washers, two nuts, a BURNDY bonding lug and all mounting hardware Achieves UL Listing The BWB680 series features options for in-ground and above-ground pools.

Key 4 5 Lay-in Lug Wire to Rebar Wire Terminal Copper Wire Grid BWB680 Water Bonding Kit 4 5 4 All BURNDY pool and spa products use stainless-steel or brass hardware. 5

Trust the BURNDY Engineered System The BURNDY Engineered System of coordinating dies, connectors and tools are designed to work together and engineered to meet stringent, accepted quality standards. Dies and connectors Tools + = Safe, easy and inspectable connection www.burndy.com -800-46-475 Customer Service Department 7 Aviation Park Drive Londonderry, NH 005-800-46-475 -60-647-599 (International) Canada -800-6-6975 (Quebec) -800-87-6487 (All other provinces) Mexico 0-5-7-65-4400 Brazil 0-55--555-75 Tool Service Center Littleton Industrial Park Littleton, NH 056-800-46-870 BURNDY LLC, 05