PANTHERALERT OPERATION & INSTALLATION MANUAL

Similar documents
600-GD & 600-GDL 600 SERIES GAS DETECTOR

Fire & Security DETECTORS

Manual for Fire Suppression & Methane Detection System

BEP FD-2 CONTOUR MATRIX FUME DETECTOR

White Paper. Best Practices for Gas Monitoring in the Commercial Kitchen

TMS TANK MANAGEMENT SYSTEM

CO2 Alarm. Operation. Application

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

ACTIVE 5 ENGINEERING MANUAL

Drayton Digistat +2RF/+3RF

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

PUSH BUTTON START INSTALLATION MANUAL

WD-AMX Water Detection Controllers

Conventional Fire Detection and Extinguishant Control System Specification

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

GST301. (Single Protection Zone) Operation Manual

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

MANUAL GSM CONTROLLER

FIREDEX Conventional Fire Panels

TS510 & TS500. Installation & User Guide. Compatible Equipment

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

SECURIT 800L+ CONTROL PANEL

INSTALLATION MANUAL CONTENTS

SPR-5 FOUR SECTOR COMPOS I TE CONTROL UN I T.

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

FIRE ALARM PANEL & SYSTEM OPERATION ID50 SYSTEM. The Fire Alarm System can be activated in the following ways :~

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

GSM Alarm System User Manual

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

EzFlex Combustible Gas Leak Detector Model EZ40

TIG INVERTER INSTRUCTION MANUAL

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

AC-115 Compact Networked Single Door Controller. Installation and User Manual

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

PART 11: START-UP PROCEDURES FOR THE INSTALLER

conventional system operation

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Ammonia Detection System Codes and Design Specifications

User s Information Guide R1A

Users Instructions BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER

Technical Overview Add-on Sensors - Smoke Alarm. Get yours direct at:

User Guide and Important Warranty Information. Suprima 30L - 100L. Wall Mounted Fan Assisted Balanced Flue Gas Boiler

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Owner s Manual. Walk-in Monitoring System 100. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

9452/9453 Installation and User Guide

Instruction manual for Firstline FCS12000CH

User's Instructions. Alpha HE CB25/33 and HE SY25

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

ICP-CP500. User's Guide ICP-CP500 Codepads

User s Manual Before using the inverter, you need to read and save the safety instructions.

Baxi Combi 80e & 105e

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

Fire Pump Controllers Remote Alarm Panels

LUCCI AIRFUSION QUEST II CEILING FAN

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

INTRODUCTION. The data provided is for The Standard Products and any variation will be dealt with at the end of this manual.

ADM1TE 5/30A DIN rail single phase two wire energy meter

Operating instructions

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

Portable Air Conditioner

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

SECTION DETECTION AND ALARM

HeatSource HS1800 Heater

Fire Standards & Regulations Are you confused?

HVAC Processes. Lecture 7

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Secure Keypads for access control

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Overview of Fire Alarm Systems and Maintenance

ACS-30-EU-EMDR-10-MOD

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

DCP Fan Controller. Version 01/2009. The engineer s choice

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

Fire Alarm system Installation Guide

Programming Logic controllers

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

User Manual. Gas fired condensing wall hung boiler. G.C.N : (12 kw) G.C.N : (18 kw) G.C.N : (24 kw)

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

User Manual THR840DUK Digital Thermostat

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

12 Volt 30 Amp Digital Solar Charge Controller

ELECTRIC CENTRAL HEATING FLOW BOILER

For installation guide see reverse of book

Baxi Platinum Combi HE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

3000W Power Inverter

! WARNING: RECREATIONAL VEHICLE (RV) Combination Carbon Monoxide and Gas Alarm USER S MANUAL Model ABOUT THIS ALARM

Transcription:

PANTHERALERT OPERATION & INSTALLATION MANUAL

PANTHERALERT Model: PA04 Gas Monitoring & Fire - Alarm & Automatic Cut Off System FUNCTION: to Monitor & Detect gas /fire/heat and to: [1] WARN - by means of alarms. [2] REDUCE RISK - by automatically closing gas valve. [3] INFORM - by indicating the activated zone on the monitor. NATURAL GAS/ LP GAS - When the mixture of Natural Gas or LP gas to air is between 5% and 15% it is potentially explosive. 5% is the lower explosive limit [LEL] 15% is the higher explosive limit [HEL] Natural / LP Gas detectors are calibrated to activate at 10% of LEL [0.5%] to give a very big safety margin. Natural Gas is lighter than air and therefore rises. LP Gas is heavier than air and therefore falls. CARBON MONOXIDE- is lighter than air. Carbon Monoxide detectors are calibrated to alarm at 100 ppm. [Parts per million] Carbon Monoxide at concentrated levels is poisonous. Exposure to even low levels (above 200ppm) over a long period of time can have adverse health consequences. You cannot smell Carbon Monoxide. Note: The utilisation of the inputs and outputs in this diagram are by way of illustration only.

HOW THE SYSTEM OPERATES If there is detection of gas or other detectors alarm (heat /fire) or there is a manual activation of an emergency stop button wired to the monitor then simultaneously the: [1] Detector - alarm sounds and the alarm visual indicator shows red. [2] Monitor - internal buzzer sounds and the zone indicator shows red. [3] Remote Alarms - will sound [if fitted]. [4] Solenoid Valve - will close. [5] There are also Volt Free contacts enabling a signal to inform via Security Panel, Building Management Systems and Auto- Diallers etc [6] The valve will stay closed until manually reset (either at the valve & monitor for manual reset valves or at the monitor for automatic reset valves). [7] The monitor will stay in alarm mode until re-set with the key. [8] The detector will stay in alarm mode until the gas has cleared. HOW TO OPERATE THE SYSTEM- 1. Insert the key into key-switch and set to the ENABLE position. 2. Switch on power at the spur unit located next to the monitor. The system is now fully operational. Monitor- Green visual indicator POWER ON Gas Detectors- Green visual indicator POWER ON The gas detectors are pre-set and require no calibration. ALARM STATE * Monitor buzzer on * monitor zone indicator red * Detector alarm sounds * detector alarm indicator red * Solenoid valve closed * remote alarms sound 1. Find out which zone has activated [see monitor]. 2. Inform relevant authority immediately. All work done on any gas installations /appliances must be carried out by an appropriately qualified CORGI registered person. Switch to DISABLE to terminate activation of alarms. 3. ONLY after the fault has been identified and rectified should you re-set system.

POWER FAILURE Monitor and detector(s) will cease to operate.on return of power the system will return to operating mode. Ensure that the gas valve, if manual re-set, is reset. EMERGENCY STOP BUTTON If an Emergency Stop Button is wired to the Panther Alert Monitor then on activation the system will alarm. Please ensure that before resetting the system, the Emergency Stop Button is returned to NORMAL position. PILOT LIGHT After a close down all pilot lights to appliances etc. must be relit. WHAT NOT TO DO [1] Reset system without finding gas leak- result: system will alarm and close down gas. [2] Forget to relight pilot lights- result: system will alarm and close down gas. [3] Use excessive steam, paint, solvents or glue in areas near the detectors-result: system will alarm and close down gas. MAINTENANCE WORK If you need to carry out maintenance work or other work which might activate the detectors switch the system to DISABLE mode. In this mode the detectors may activate but the valve will not close and there will be no activation of the monitor. Please ensure you return to ENABLE mode when the work is completed. NUISANCE ALARMS Can be caused by solvents, steam, paint etc. Ensure that the system is in DISABLE mode until these fumes have gone. INSPECTION AND TESTING The system should be tested every 6 months and a maintenance check and test carried out every 12 months. The monitor and detectors carry a 1 year warranty. Detectors MUST be replaced after 5 years.

Panther Alert - Model PA04 SPECIFICATION The Panther Alert Monitor is a 4 channel unit designed to operate with gas detectors, manual emergency push buttons, heat detectors, thermal fire links etc. The monitor has 4 LED to indicate the zone status and one LED to indicate power status. There is a key reset facility with ENABLE and DISABLE positions. There are volt free contacts and an Aux. +12 V supply and a 240V input. There are settings to enable NO or NC operation, common or separate output relays, zone output, and the operation of an internal buzzer. Technical Specification: Supply Voltage: 230-250 V AC Current Draw: < 250MA Idle : < 500MA Alarm Status Operating Voltage: + 12 V DC Operating Current : < 100MA Idle: < 600 MA Full Alarm Status AUX Supply: + 12 Regulated: Max. Current 1 Amp Fused Visual Indicators Green LED: Power Supply. Red LED: Alarm Status (Zoned) Red LED: Aux. Supply (on PCB) Audible Alarm 2.4kHz: 85bd at 20 cm ( lid off) Outputs: Four change over contacts Rate at 240V ac 6A Key Switch Operation: Enable -Reset (Key removable only in Enable position) Size: 250 mm x 178 mm x 76 mm

PANTHERALERT - Model PA04 NATURAL, LP AND CARBON MONOXIDE GAS DETECTORS - INSTALLATION NOTES The detector should only be installed by a competent electrician and wired in accordance with current IEE regulations. Isolate the mains electricity supply before starting installation. Do not tamper with the inside of this detector -no maintenance or adjustment is required. WIRING 240v circuit LIVE Brown NEUTRAL Blue SWITCHING CIRCUIT black/ black LOCATION The detector is designed to operate inside a building with free access to air in the room. They should be wall mounted. Natural Gas and Carbon Monoxide are lighter than air and these detectors should be located between a minimum height equal to 75% of the room height and a maximum height 30cms below the ceiling. LP Gas is heavier than air. Detectors should be located 30cms from floor level. Do not install the detector: [1] Directly above a cooker or sink [2] Next to a window or extractor fan [3] In areas of extreme temperature below -5 C or +40 C [4] In damp or humid areas. Heat Detectors Locate on ceiling- off set from the Burners. Thermal Links- Locate above burners APPLICATIONS Boiler Plant Rooms - Place as instructed above. Locate on wall nearest to Boiler(s) and gas train. Ensure detectors are on Boiler side of any ventilation airflow. Laboratories - Place as instructed above. It is recommended that power to each detector is individually isolated. Kitchens - Place as instructed above. Avoid areas of steam and excessive heat. Site away from toasters & cookers etc. Each detector will cover an area 5 metres x 5 metres. Additional detectors may be required for enclosed and meter areas.