Powerbus Busway. Scalable, efficient, and flexible power distribution with zero footprint and high tap-off circuit density

Similar documents
How To Power A Bladecenter H Servers

Rack Systems Solutions

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Rack Power Distribution

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

Emerson Network Power Rack PDU Systems

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

APC 3Phase Power Distribution

Rack Power Distribution. Worldwide

Communicate and view data from meters with one simple device

High-Efficiency AC Power Distribution for Data Centers

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

ED1259R5 Updated April 2011 For latest specs visit

CRITICAL POWER MONITORING CPM20/CPM21 DETAILS

Racks & Enclosures. Deliver. Design. Define. Three simple words that clearly describe how we approach a Data Center project.

T1 Backhaul Connectivity Solution All Products :: Application Note

IP DSLAM IDL Quick Installation Guide

Power Commander Power Distribution Units from Wiremold/Legrand offer

Gain energy insight and control with PowerLogic. PowerLogic EGX300 integrated gateway-server

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

RELIABLE AND FLEXIBLE POWER FOR YOUR DATA CENTRE

A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture

A Scalable, Reconfigurable, and Efficient Data Center Power Distribution Architecture

InstaPATCH ZERO Solution Guide

Circuit Breakers. Next Generation of Protection Capabilities

Cabinets 101: Configuring A Network Or Server Cabinet

HVL 5 38 kv Load Interrupter Switchgear. The Standard for Performance, Protection and Dependability

Distributing Power to Blade Servers

Power Distribution Considerations for Data Center Racks

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Instruction / Installation Sheet DataComm Electronics WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Power Solution

Cable/Conduit Conversion

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

Square D Model 6 Motor Control Centers

MCR1900 Media Converter 19-Slot Chassis

Secondary Unit Substations

Addendum #2 Contract UK-11-13

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

Union County Public Schools. Facilities Department. Electrical. Safe Work Practices

Optimizing Rack Power Distribution

Applications. Remote Display Mounting Kits

Terminal Blocks & Power Distribution Terminal Blocks. Make your connection

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Comparing Data Center Power Distribution Architectures

ADC-APC Integrated Cisco Data Center Solutions

Masterclad Medium Voltage Passive Arc-Resistant Switchgear

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

LIEBERT VNSA Installation Sheet

8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Cabinet V800 V800 CABINETS

Simple Electrical Utility Cost Allocation Solutions

Power-Zone 4 Arc Resistant Low Voltage Switchgear

Bypass transfer switch mechanisms

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Eaton epdu. Intelligent and flexible power distribution

QuickSpecs. HP Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview

QuickSpecs. HP Managed Power Distribution Units (mapdu) Overview

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Decision-Maker Paralleling System. Power Distribution Switchboards and Circuit Breakers. Standard Features

Sense Components. Sense monitor. Antenna assembly. External mounting kit Current sensors. Download the Sense app. Go to sense.com/app.

APC Step-Down Transformer. User s Manual

Precisely distribute, monitor, analyze and manage power distribution in your facility to maximize processing capacity and promote power efficiency.

MCC Ratings. Voltage Rating

1 & 2 CIRCUIT. Architectural grade ISO 9001 quality JIT availability Open architecture ready for your fixtures now!

Eaton epdu Data Center Product Catalog

Smart-UPS On-Line 230 V

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Increase the efficiency of power distribution in your high-density data center

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

How To Power A Power Supply On A Powerline From A Power Source To A Power Box

Power Management Module 2. Installation

THERMAL MANAGEMENT SOLUTIONS

Retail & Commercial Solutions. Siemens EcoView. Energy Management Made Easier.

How to Estimate the Cost of a Clean Room and Data Center Equipment Electrical Work. Section 2 Types of Methods of Measurements page 4

PE6108/PE6208/PE8108/PE8208

ZONIT POWER DISTRIBUTION SYSTEM ORDER CATALOG

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

Advanced Heat-Tracing Control System

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

SWITCHGEAR SOLUTIONS FOR MISSION CRITICAL APPLICATIONS. Presented by SAI Advanced Power Solutions

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Metering and Monitoring. Basis of Design

Cove lighting and tight space RGB LED luminaire

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Power Distribution in Data Centers: STARLINE Track Busway, PX ipdus and Power IQ

Build for Tomorrow. Today.

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Chassis, Power Supply, and Element Management

Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation

Transcription:

Powerbus Busway Scalable, efficient, and flexible power distribution with zero footprint and high tap-off circuit density 100 A, 225 A, and 400 A Make the most of your energy SM

Helping Facilities Be More Scalable, Flexible, and Energy-Efficient Zero footprint, saving valuable floor space for revenueproducing IT racks or machinery The Powerbus busway delivers flexible and efficient overhead power distribution and offers scalability by featuring the highest tap-off unit density on the market. This modular solution minimizes unintended downtime and improves safety while optimizing energy efficiency. Scalable to meet future power demands Easy to install, move, and reconfigure Flexibility to select plug-in units to fit your needs Metering options for greater energy efficiency Powerbus Busway Features and Benefits Scalable High plug-in unit density up to 20 ports every 10 feet Easy to move, add, or change units to meet power needs Up to three branch circuits per plug-in unit 100 A 400 A ratings use same plug-in units Flexible Modular design and full catalog of tap-off units, drop cords with connectors, power feed units, fittings, and accessories to fit your power and application needs Install a plug-in unit or power feed unit with metering or without wherever it s needed Tool-less plug-in unit installation Superior plug-in design makes installation fast and easy Hanger options let designers customize each application Efficient Overhead design maximizes cooling air flow while increasing accessibility to components Zero footprint saves valuable floor space for revenue-producing machinery, work cells, or IT racks Energy-efficient copper bars reduce power distribution heat losses Plug-in units and power feed units offer optional PowerLogic PM5350 series metering to monitor energy usage > > PowerLogic EGX300 integrated gateway/server offers remote access to real-time data with simple Ethernet connection Protective Design UL -listed 857 busway standard for safety Above-equipment installation makes identifying and tracing circuits easy Balanced plug-in unit design and optional handles give contractors and technicians more stability when climbing a ladder to install Explore the Powerbus 3D Interactive Model! Scan this QR code with your smartphone to download the itunes 3D Interactive Model app. 2 I Powerbus Busway

Busway Power Distribution Features Power feed units The feed unit connects incoming cable and conduit to power the busway straights. Metering option monitors power consumption for busway run, while barriered compartments provide access to metering devices without exposing workers to input power terminals. Drop cord connector sets Pre-terminated cord-sets in 2- to 12-foot lengths hang down from the plug-in units for quick connection to equipment below and use standard UL, IEC, or CSA connectors. Busway straight sections UL listed 4- and 10-foot busway straights feature high-density outlet ports every 11.4 inches in front and back. Spring-type bus joint connections ease installation and reduce maintenance. No special tools required for installation. Plug-in unit designs metered or unmetered Drop cord units are sized for any busway opening with no interference. Multi-circuit-capable tap-off units house Square D circuit breakers, and up to three cord sets to reduce clutter. A hook-swing motion and quick quarter-turn hook fastener offer fast, easy, and tool-less installation. Tool-less installation and jaw-like connections Ease of installation comes from the jaw-like connection, supporting mounting bracket, and fastening hook that locks the plug-in unit in place with no tools required. Integrated metering Optional PowerLogic metering and communications monitor more than 30 power conditions, including pre-configured alarm functions. Meter individual plug-in unit circuits or entire busway run. System-mounting options Variety of thread rod suspension hangers are available to match your installation needs. Other labor-saving options include I-beam mounting clamps and new NetShelter IT rack-mounting brackets to minimize space in data center applications. Powerbus Busway I 3

Technical Specifications Busway Straights 4 ft. (1.2 m) 10 ft. (3 m) Electrical ratings: Maximum current and voltage Outlets per busway straight Plug-in openings: Spacing and ingress protection rating Quantity of conductor bars Short-circuit rating Housing material and color Housing ingress protection rating Conductor bar material Bus joint connection material Weights Suspended hanger spacing Mounting bracket spacing on NetShelter SX rack enclosures 100 A Busway Straight H x W x D 225 A Busway Straight H x W x D 400 A Busway Straight, H x W x D 100 A @ 600 V 225 A @ 600 V 400 A @ 600 V 4-ft. busway straight: 6 10-ft. busway straight: 20 1 outlet per 11.4 inches in front and back of busway straight Solid object ingress protection to IP2X standard 5 bars maximum (3L, N, 200% N or Isolated Gnd) 100 A: 14 ka @600 V 225 A: 22 ka @600 V 400 A: 35 ka @600 V Electrical-grade aluminum in black or natural finish IP40 for standard and side mount orientation Silver-plated copper Silver-plated copper (maintenance-free, high-pressure spring-type) 100 A: 3 bar 2.9 lb./ft. 4 bar 3.2 lb./ft. 5 bar 3.4 lb./ft. 225 A: 3 bar 4.5 lb./ft. 4 bar 5.1 lb./ft. 5 bar 5.8 lb./ft. 400 A: 3 bar 6.9 lb./ft. 4 bar 7.9 lb./ft. 5 bar 8.9 lb./ft. 5 ft maximum 5 ft maximum 4-ft. busway straight: 6.94 x 48 x 2.6 in. (176 x 1,219 x 66 mm) 10-ft. busway straight: 6.94 x 120 x 2.6 in. (176 x 3048 x 66 mm) 4-ft. busway straight: 6.94 x 48 x 3.47 in. (176 x 1,219 x 88 mm) 10-ft. busway straight: 6.94 x 120 x 3.47 in. (176 x 3048 x 88 mm) 4-ft. busway straight: 6.94 x 48 x 3.47 in. (176 x 1,219 x 88 mm) 10-ft. busway straight: 6.94 x 120 x 3.47 in. (176 x 3,048 x 88 mm) Regulatory approvals, codes and standards UL 857 & cul & ANCE, NEMA BU1, NFPA 70E, CSA Z462 Center Tap Boxes / Power Feed Units (PFU) Optional row-level metering and communications Incoming wire lug configuration Color Housing ingress protection rating H x W x D 100 A PFU with busway section H x W x D 225 A PFU with busway section H x W x D 400 A PFU with busway section H x W x D 100 A PFU with metering and busway section H x W x D 225 A PFU with metering and busway section H x W x D 400 A PFU with metering and busway section PowerLogic PM5350-series power meter and EGX-300 integrated gateway-server* 100 A: One #14-1/0 per bar + One ground #14-1/0 225 A: One #6-300 kcmil per bar + One ground #10-2/0 400 A: Two 600 kcmil per bar + Two ground #10-2/0 Black NEMA Type 1 general purpose indoor 14.5 x 24 x 7.8 in. (368 x 610 x 198 mm) 14.5 x 38 x 9.7 in. (368 x 965 x 247 mm) 14.5 x 43 x 9.7 in. (368 x 1,092 x 247 mm) 21 x 30 x 9.3 in. (533 x 762 x 236 mm) 21 x 38 x 10.2 in (533 x 965 x 259 mm) 21 x 43 x 10.2 in. (533 x 1,092 x 259 mm) Approximate Weights (Dependent on qty of conductor bars) PFU without metering PFU with metering 100 A: 50 lb. (23 kg); 225 A: 65 lb. (29 kg); 400 A: 95 lb. (43 kg) 100 A: 70 lb. (32 kg); 225 A: 90 lb. (41 kg); 400 A: 120 lb. (54 kg) 4 I Powerbus Busway

Plug-In Unit / Tap-Off Unit Optional branch circuit level metering Maximum voltage PowerLogic PM5350-series power meter communicates to metered Power Feed Unit or to available EGX Plug-In Unit with integrated gateway server 480 Y/277 V Standard interrupting ratings*** QOU circuit breakers 10 ka @ 120 V, 208 V, 240 V Optional interrupting ratings*** QOU-VH circuit breakers 22 ka @ 120 V, 208 V, 240 V Standard interrupting ratings*** EDB circuit breakers 25 ka @ 120 V 18 ka @ 240 V, 480 Y/277 V Optional interrupting ratings*** EGB circuit breakers 35 ka @ 120 V, 240 V, 480 Y/277 V Breakers Total Unit Amperage Drop Cord Connector Drop Cord Connector Amperage Drop Cords Weight H x W x D Color Enclosure ingress protection rating 1-, 2-, or 3-pole QOU breakers maximum of 6 poles 1-, 2-, or 3-pole EDB breakers maximum of 3 poles 100 A NEMA, IEC, CS 15 A to 60 A Qty 1 3, type SOOW in 2 12-foot lengths 18 lb. (8 kg)** PBPQOU: 12 x 8.475 x 5.5 in. PBPEDB with or without metering: 14 x 8.475 x 5.7 in. PBPEGX plug in unit: 14 x 8.475 x 5.7 in. Black NEMA Type 1 general purpose indoor * Refer to seperate technical documents for power-meter and server-gateway specifications. ** Weight will vary depending on breaker and cord-connector set configuration. *** The short-circuit rating of plug-in units are limited by the mounted busway rating and to 10 ka when provided with drop cord connectors or receptacles. Schneider Electric has carefully reviewed wording in product hazard messages to alert users to potential hazards, how to avoid those hazards, and the consequences of not following hazard messages. Workplace safety standards such as NFPA 70E and CSA Z462 are clear that the proper method to work on or near electrical equipment is in a de-energized state. However, it is recognized that the standards identify exceptions where powering down the equipment is infeasible or actually introduces additional hazards. While elimination of all risk is not possible, in those situations where it can be demonstrated that energized work is necessary, certain tasks, including the installation or removal of Powerbus circuit breaker plug-in units, may be performed on an energized Powerbus busway only after the user has demonstrated that the application meets the required exceptions in NFPA 70E, CSA Z462, or other standards as appropriate and employs the work practices and personal protective equipment prescribed in the standard. Powerbus Busway I 5

For more information, ask your authorized Schneider Electric Distributor, visit www.schneider-electric.us/go/powerbus or call 888-778-2733. Schneider Electric USA 1415 S. Roselle Road Palatine, IL 60067 Tel: 847-397-2600 Fax: 847-925-7500 www.schneider-electric.com/us See the Powerbus video! Scan this QR code with your smartphone, or click here to view on your desktop. Document Number 5600BR1201R10/13 February 2014 2014 Schneider Electric. All Rights Reserved. Schneider Electric, PowerLogic, NetShelter, Square D, and Make the most of your energy are trademarks owned by Schneider Electric Industries SAS or its affiliated companies. All other trademarks are property of their respective owners. itunes is a registered trademark of Apple Inc. 998-1169301_US