1 AC Power For Business-Critical Continuity Emerson Network Power Rack PDU Systems Product Selection Guide - North American Models
2
3 TABLE OF CONTENTS 1.0 EMERSON NETWORK POWER RACK PDU SYSTEMS Safety and Agency Compliance DETERMINING THE RIGHT EMERSON PDU FOR YOUR APPLICATION KNURR DI-STRIP PRODUCT SELECTION GUIDE - BASIC RACK PDUS Overview - Basic Rack PDUs Basic Rack PDU Optional Cord Sets Dimensional Drawings - Basic Rack PDUs LIEBERT MPH PRODUCT SELECTION GUIDE - MANAGED RACK PDUS Overview - Managed Rack PDUs Specifications - Liebert MPH Model Number Configuration - Liebert MPH Managed Rack PDU Optional Cord Sets and Cable Restraints Dimensional Drawings - Managed Rack PDUs LIEBERT MPX - ADAPTIVE RACK PDUS Overview - Adaptive Rack PDUs MPX PRC (Power Rail Chassis) MPX PEM (Power Entry Module) and MPX IPC (Input Power Cord) MPX BRM (Branch Receptacle Module) Adaptive Rack PDU Optional Accessories Cord Sets and Cable Restraints Liebert RPC (RPC-1000) and Accessories Part Numbers for Liebert RPC and Accessories Ports on the Liebert RPC Liebert RPC Capabilities and Benefits RPC BDM Basic Display Module Temperature/Humidity Sensor LIEBERT MPX SYSTEM PRODUCT SELECTION GUIDE STEP 1 - Select an MPX PRC (Quantity x 1) STEP 2 - Select an MPX PEM / MPX IPC (Quantity x 1) STEP 3 - Select an MPX BRM STEP 4 - Select Communication Options System Selection Guide Specifications for Liebert MPX Components Dimensional Drawings - Adaptive Rack PDUs i
4 FIGURES Figure 1 Knurr DI-STRIP Figure 2 Knurr DI-STRIP Figure 3 Knurr DI-STRIP Figure 4 Knurr DI-STRIP Figure 5 Knurr DI-STRIP Figure 6 Knurr DI-STRIP Figure 7 Knurr DI-STRIP Figure 8 Knurr DI-STRIP Figure 9 Knurr DI-STRIP Figure 10 Knurr DI-STRIP Figure 11 Knurr DI-STRIP Figure 12 Knurr DI-STRIP Figure 13 Knurr DI-STRIP Figure 14 Knurr DI-STRIP Figure 15 Knurr DI-STRIP Figure Knurr DI-STRIP Figure 17 Knurr DI-STRIP Figure 18 Knurr DI-STRIP Figure 19 Knurr DI-STRIP Figure 20 Knurr DI-STRIP Figure 21 Knurr DI-STRIP Figure 22 Knurr DI-STRIP Figure 23 Liebert MPH rack mount power strip Figure 24 Liebert MPH vertical power strip Figure 25 Liebert MPX 1880 and 1035 models and components Figure 26 MPX PRC (Power Rail Chassis) Figure 27 Liebert RPC ports Figure 28 RPC BDM Figure 29 Temperature/humidity sensor Figure 30 Liebert MPX MPXPRC-1035mm mixed modules Figure 31 Liebert MPX MPXPRC-1880mm mixed modules TABLES Table 1 Specifications - Knurr DI-STRIP Table 2 Cord sets - Knurr DI-STRIP Table 3 Specifications - Liebert MPH Table 4 Cord sets and cable restraints - Liebert MPH Table 5 Selections for Power Entry Module MPXPEM-NVAXXAXX Table 6 Selections for Power Entry Module MPXPEM-NHBXXV Table 7 Selections for Power Entry Module MPXPEM-NHBXXX Table 8 Selections for Power Entry Module MPXPEM-NHBXXW Table 9 Specifications - MPX BRM ii
5 1.0 EMERSON NETWORK POWER RACK PDU SYSTEMS Emerson Network Power Rack PDU Systems Emerson Network Power s Rack PDU Systems is a family of products that delivers power and management to connected IT equipment through a global and comprehensive offering including Basic, Managed and Adaptive Rack PDU systems. Each PDU type offers simplified installation and easy operation. Each type is compatible with standard rack enclosures. These Emerson Rack PDUs provide easy low-cost installation, simple relocation, security and proven design and performance. Emerson Rack PDUs can be set up with varying degrees of power-monitoring and management. When power or management requirements grow, the adaptive PDUs are scalable, enabling them to grow with the installation. Emerson PDUs are available for the entire spectrum of power needs of every type of rack equipment. Knurr DI-STRIP - Basic Rack PDU systems, provide a broad range of power distribution capacities and connectivity solutions in a robust package. Liebert MPH - Managed Rack PDUs with single-phase or three-phase capability for fixed power input/output with remote management support; one-piece unit with monitoring at the branch level and control at the receptacle level; available in rack-mount and zero U configurations. Liebert MPX - Adaptive Rack PDUs built with modular and scalable components that can be installed and reconfigured on-site to meet changing input and output power connectivity needs; with remote monitoring at the branch level and receptacle management and control at the receptacle level. 1.1 Safety and Agency Compliance Where a conflict arises between the following documents and statements made herein, the statements in this specification will govern. North American Units - 120V and 208V (Single-Phase and Three-Phase) UL Information Technology Equipment CAN/CSA-C22.2 No Information Technology Equipment FCC, Title 47, Part 15 Subpart B for Class A operation as defined by ANSI Standard C63.4 ISTA Procedure 1A and 2A RoHS Compliant 1
6 Determining the Right Emerson PDU for Your Application 2.0 DETERMINING THE RIGHT EMERSON PDU FOR YOUR APPLICATION Each of the Rack PDU systems Emerson offers is well-suited for delivering power to sensitive, highcapacity, rack-mounted equipment. Determining which is best for a particular installation requires knowing the basic power requirements of the equipment in the rack, deciding on the acceptable or preferable level of monitoring and control and then balancing those considerations against site requirements. The Emerson Rack PDU product line includes models to fit all types of installations: new or established; stable or rapidly changing; contracting or expanding. Each type of installation may require any or all types of Emerson Rack PDUs. After determining your requirements, refer to the data and specifications for each product. 2
7 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs 3.0 KNURR DI-STRIP PRODUCT SELECTION GUIDE - BASIC RACK PDUS 3.1 Overview - Basic Rack PDUs Part Number The Knurr DI-STRIP, a Basic Rack PDU system, provides a broad range of power distribution capacities and connectivity solutions in a robust package. The Knurr DI-STRIP includes an input power cord with appropriate input plug connection and hydraulic-magnetic branch rated overload protection as appropriate; basic rack mounting provisions are also provided. Knurr DI-STRIP Rack PDUs are available in rack mount and vertical zero-u form factors. The Knurr DI-STRIP fits most standard 600mm width network equipment rack enclosures. Product fit should be confirmed for each application. Table 1 Specifications - Knurr DI-STRIP INPUT OUTPUT Voltage Max Continuous kw* Phase Plug Receptacle/Socket Configuration NEMA 5-15P (9) NEMA 5-15R Form Factor Rack mount or Vertical NEMA 5-15P (12) NEMA 5-15R Vertical NEMA 5-15P (18) NEMA 5-15R Vertical NEMA L5-20P (9) NEMA 5-20 T-Slot Vertical NEMA 5-20P (12) NEMA 5-20 T-Slot Vertical NEMA L5-20P (12) NEMA 5-20 T-Slot Vertical NEMA L5-30P (24) NEMA 5-20 T-Slot Vertical NEMA L6-20P (9) IEC-C13 sockets Vertical ** IEC-C20 inlet (9) IEC-C13 sockets Rack mount or Vertical NEMA L6-20P (12) IEC-C13 sockets Vertical ** IEC-C20 inlet (12) IEC-C13 sockets Vertical NEMA L6-30P (4) IEC-C19 sockets Vertical NEMA L6-30P (24) IEC-C13 sockets Vertical NEMA L6-30P (20) IEC-C13 + (4) IEC-C19 sockets Vertical / NEMA L21-20P (18) IEC-C13 + (6) IEC-C19 sockets Vertical / NEMA L21-20P (27) IEC-C13 + (6) IEC-C19 sockets Vertical / NEMA L21-20P (27) 5-20 T-Slot Vertical / NEMA L21-30P (6) IEC-C19 sockets Vertical / NEMA L21-30P (18) IEC-C13 + (6) IEC-C19 sockets Vertical / NEMA L21-30P (27) IEC-C13 + (6) IEC-C19 sockets Vertical IEC60309 (3 pole, 4 wire, 250VAC, blue) (2) IEC (3 pole, 4 wire, 250VAC, blue) All input cords are 10 ft. (3m) in length. * Formulas used to calculate the kw: For single-phase: input voltage x max continuous amps = watts For three-phase: input voltage x max continuous amps x 1.73 = watts ** Knurr DI-STRIP output expansion modules require the use of a cord set for input power. (42) IEC-C13 + (6) IEC-C19 sockets (42) IEC-C13 + (6) IEC-C19 sockets Vertical Vertical 3
8 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs 3.2 Basic Rack PDU Optional Cord Sets Output Cord Sets Output cord sets are available to support conversion of Rack PDU power output receptacles to alternative power output connections and to support Rack PDU output expansion capabilities. Conversion of power output connections can be provided on Rack PDUs with IEC-C19 receptacles. The output cord set for these systems includes an IEC-C20 plug to connect to the IEC-C19 receptacle, a 3 ft. (1m) power cord and receptacle to connect to user equipment. Available receptacles include: IEC-C13 to connect to IEC-C14 equipment plugs and IEC-C19 to connect to NEMA L6-20P equipment plugs. Knurr DI-STRIP output expansion modules are powered via an IEC-C20 input connection. These systems provide output expansion capabilities when connected to a receptacle on a separate Rack PDU. The output cord set for these systems includes an IEC-C19 receptacle to connect to the IEC-C20 plug on the output expansion Knurr DI-STRIP, a 3 ft. (1m) power cord and plug to connect to the Rack PDU receptacle providing power. Available plugs include: IEC-C20 to connect to an IEC-C19 Rack PDU receptacle. Input Cord Sets Input cord sets are available to support conversion of Rack PDU power input connections to alternative power input connections. Conversion of power input can be provided on Rack PDUs with L5-20P plug connections. The input cord set includes an L5-20R receptacle to connect to the L5-20P Rack PDU plug, a 1 ft. (0.3m) power cord and a 5-20P plug. Table 2 Cord sets - Knurr DI-STRIP Cord Sets Output Cord Sets - Power Output Conversion G5 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 3 ft. (1m) G6 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 10 ft. (3m) G9 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 3 ft. (1m) G10 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 10 ft. (3m) Output Cord Sets - Power Output Expansion G7 Output Cord Set - Power Output Expansion - IEC-C20 to IEC-C19, 3 ft. (1m) G8 Output Cord Set - Power Output Expansion - IEC-C20 to IEC-C19, 10 ft. (3m) G3 Output Cord Set - Power Output Expansion - IEC-C14 to IEC-C19, 3 ft. (1m) G4 Output Cord Set - Power Output Expansion - IEC-C14 to IEC-C19, 10 ft. (3m) Input Cord Sets - Power Input Conversion G12 Input Cord Set - Power Input Conversion - L5-20R to 5-20P, 1 ft. (0.3m) 4
9 3.3 Dimensional Drawings - Basic Rack PDUs Figure 1 Knurr DI-STRIP Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (73mm) 17.6" (447mm) FRONT VIEW 12.2" (311mm) REAR VIEW SIDE VIEW INPUT POWER Input Cord 10 ft. (3m) 5-15P (2-pole, 3-wire) Input Plug Phase Voltage (VAC) Max. Cont. 5-15P OUTPUT POWER Bank Receptacle Type (Qty) Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank R (9) " (63mm) 1.7" (44mm) 2" (50mm) AGENCY: CSA tested to UL RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 17.6" (447mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 2.5 lb. (1.1kg) 3. Shipping dimensions: 18.9" (480mm) L x 2.8" (71mm) W x 3.3" (84mm) D 4. Shipping weight: 2.8 lb. (1.3kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 3 5
10 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 2 Knurr DI-STRIP DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (123mm) 19.6" (497mm) FRONT VIEW 12.2" (311mm) REAR VIEW SIDE VIEW INPUT POWER Input Cord Input Plug Phase 10 ft. (3m) 5-15P (2-pole, 3-wire) Voltage (VAC) Max. Cont. 5-15P OUTPUT POWER Bank Receptacle Type (Qty) Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank R (9) " (63mm) 1.7" (44mm) 2" (50mm) AGENCY: CSA tested to UL RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 2.7 lb. (1.2kg) 3. Shipping dimensions: 22.2" (565mm) L x 2.8" (70mm) W x 3.3" (85mm) D 4. Shipping weight: 3.1 lb. (1.4kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 3 6
11 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 3 Knurr DI-STRIP DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (697mm) FRONT VIEW 1.7" (44mm) 12.7" (323mm) 12.2" (311mm) 2.5" (63mm) REAR VIEW 2" (50mm) SIDE VIEW INPUT POWER 5-15P (2-pole, 3-wire) Input Input Cord Plug Phase 10 ft. (3m) OUTPUT POWER Bank Receptacle Type (Qty) Voltage (VAC) Max. Cont. 5-15P Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank R (18) AGENCY: CSA tested to UL RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 27.4" (697mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3.3 lb. (1.5kg) 3. Shipping dimensions: 42" (1065mm) L x 2.4" (60mm) W x 3" (75mm) D 4. Shipping weight: 3.8 lb. (1.72kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 3 7
12 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 4 Knurr DI-STRIP DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (447mm) FRONT VIEW REAR VIEW SIDE VIEW INPUT POWER Input Input Cord Plug Phase 10 ft. (3m) L5-20P (2 pole, 3 wire) Voltage (VAC) Max. Cont. L5-20P OUTPUT POWER Bank Receptacle Type (Qty) Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank R (9) " (44mm) 2" (50mm) AGENCY: CSA tested to UL RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 17.6" (447mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3 lb. (1.35kg) 3. Shipping dimensions: 26.8" (680mm) L x 2.4" (60mm) W x 3.9" (100mm) D 4. Shipping weight: 3.4 lb. (1.54kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 3 8
13 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 5 Knurr DI-STRIP DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (123mm) 19.6" (497mm) FRONT VIEW 12.2" (311mm) 2.5" (63mm) 1.7" (44mm) REAR VIEW 2" (50mm) SIDE VIEW INPUT POWER Input Input Cord Plug Phase 10 ft. (3m) OUTPUT POWER Bank Receptacle Type (Qty) 5-20P (2-pole, 3-wire) Voltage (VAC) Max. Cont. 5-20P Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank R (9) AGENCY: CSA tested to UL RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3.5 lb. (1.57kg) 3. Shipping dimensions: 26.8" (680mm) L x 2.4" (60mm) W x 3.9" (100mm) D 4. Shipping weight: 3.9 lb. (1.76kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 3 9
14 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 6 Knurr DI-STRIP DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (123mm) 19.6" (497mm) FRONT VIEW 12.2" (311mm) 2.5" (63mm) 1.7" (44mm) REAR VIEW 2" (50mm) SIDE VIEW INPUT POWER Input Cord Input Plug Phase 10 ft. (3m) OUTPUT POWER Bank Receptacle Type (Qty) L5-20P (2-pole, 3-wire) Voltage (VAC) Max. Cont. L5-20P Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank R (12) AGENCY: CSA tested to UL RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3.2 lb. (1.47kg) 3. Shipping dimensions: 24.6" (625mm) L x 2.4" (60mm) W x 3.9" (100mm) D 4. Shipping weight: 3.5 lb. (1.6kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 3 10
15 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 7 Knurr DI-STRIP " (46mm) 20A branch circuit breakers Branch 1 20A branch circuit breakers Branch 2 DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (44mm) 43.2" (1097mm) FRONT VIEW.6" (422mm) 24.5" (622mm) 2.1" (53mm) REAR VIEW 3.3" (85mm) SIDE VIEW L5-30P (2-pole, 3-wire) INPUT POWER Input Cord Input Plug Phase 10 ft. (3m) OUTPUT POWER Branch Receptacle Type (Qty) Voltage (VAC) Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Branch R (12) R (12) 120 Max. Cont. L5-30P AGENCY: CSA tested to UL RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 43.2" (447mm) L x 1.7" (44mm) W x 3.3" (85mm) D 2. Unit weight: 7.51 lb. (3.4kg) 3. Shipping dimensions: 44.9" (1140mm) L x 2.8" (70mm) W x 6.3" (0mm) D 4. Shipping weight: 8.4 lb. (3.8kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 4 11
16 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 8 Knurr DI-STRIP DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (447mm) FRONT VIEW REAR VIEW SIDE VIEW INPUT POWER Input Input Cord Plug Phase 10 ft. (3m) L6-20P (2-pole, 3-wire) Voltage (VAC) Max. Cont. L6-20P OUTPUT POWER Bank Receptacle Type (Qty) Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank 1 IEC-C13 (9) " (44mm) 2" (50mm) AGENCY: CSA tested to UL RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 17.6" (447mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3.2 lb. (1.4kg) 3. Shipping dimensions: 24.6" (625mm) L x 2.4" (60mm) W x 3.9" (100mm) D 4. Shipping weight: 3.4 lb. (1.5kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 3 12
17 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 9 Knurr DI-STRIP DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (447mm) FRONT VIEW IEC-C20 inlet 2.5" (63mm) 12.2" (311mm) 2.9" (73mm) 1.7" (44mm) REAR VIEW 2" (50mm) SIDE VIEW AGENCY: CSA tested to UL RoHS compliant (reduction of hazardous substances) INPUT POWER Input Cord Input Phase 10 ft. (3m) * Requires a cordset OUTPUT POWER Bank IEC-C20 Inlet * Receptacle Type (Qty) Voltage (VAC) Max. Cont Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank 1 IEC-C13 (9) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 17.6" (447mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 1.5 lb. (0.7kg) 3. Shipping dimensions: 19" (483mm) L x 3" (75mm) W x 2.4" (60mm) D 4. Shipping weight: 1.7 lb. (0.8kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 3 13
18 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 10 Knurr DI-STRIP DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (497mm) FRONT VIEW 4.8" (123mm) 12.2" (311mm) 2.5" (63mm) 1.7" (44mm) REAR VIEW 2" (50mm) SIDE VIEW L6-20P (2-pole, 3-wire) AGENCY: CSA tested to UL RoHS compliant (reduction of hazardous substances) INPUT POWER Input Input Cord Plug Phase 10 ft. (3m) OUTPUT POWER Bank Receptacle Type (Qty) Voltage (VAC) Max. Cont. L6-20P Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank 1 IEC-C13 (12) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 3.4 lb. (1.5kg) 3. Shipping dimensions: 26.8" (680mm) L x 2.4" (60mm) W x 3.9" (100mm) D 4. Shipping weight: 3.7 lb. (1.68kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 3 14
19 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 11 Knurr DI-STRIP IEC-C20 INLET 19.6" (497mm) FRONT VIEW 4.8" (123mm) 12.2" (311mm) 2.5" (63mm) DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A 1.7" (44mm) / REAR VIEW 2" (50mm) SIDE VIEW AGENCY: CSA tested to UL RoHS compliant (reduction of hazardous substances) INPUT POWER Bank Input Input Cord Plug Phase 10 ft. (3m) IEC-C20 inlet * * Requires a cordset OUTPUT POWER Receptacle Type (Qty) Voltage (VAC) Max. Cont Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Bank 1 IEC-C13 (12) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 19.6" (497mm) L x 1.7" (44mm) W x 2" (50mm) D 2. Unit weight: 1.8 lb. (0.8kg) 3. Shipping dimensions: 22.6" (575mm) L x 2.4" (60mm) W x 3" (75mm) D 4. Shipping weight: 2.1 lb. (0.9kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 3 15
20 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 12 Knurr DI-STRIP A branch circuit breaker Branch " (447mm) FRONT VIEW REAR VIEW 1.8" (46mm) SIDE VIEW INPUT POWER Input Cord Input Plug Phase Voltage L6-30P (2-pole, 3-wire) Max. Cont. 10 ft. (3m) L6-30P OUTPUT POWER Branch Receptacle Type (Quantity) Per Receptacle Type Phase Voltage (VAC) IEC-C19 (2) IEC-C19 (2) Max. Continuous Per Receptacle Per Branch A branch circuit breaker Branch 2 DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (44mm) 3.3" (85mm) AGENCY: CSA tested to UL RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage Temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit Dimensions: 17.6" (447mm) L x 1.7" (44mm) W x 2.0" (50mm) D 2. Unit Weight: 4.8lb. (2.2kg) 3. Shipping Dimensions: 29.0" (740mm) L x 6.3" (0mm) W x 2.7" (70mm) D 4. Shipping Weight: 5.5lbs (2.5kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 3
21 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 13 Knurr DI-STRIP " (46mm) 20A Branch Circuit Breaker 20A Branch Circuit Breaker BRANCH 1 BRANCH 2 DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (1097mm) FRONT VIEW.6" (422mm) 24.5" (622mm) REAR VIEW INPUT POWER Input Cord Input Plug Phase Voltage (VAC) Max Cont. 10 ft/3.0m L6-30P OUTPUT POWER L6-30P (2 Pole, 3 Wire) Per Receptacle Type Receptacle Type Branch (Quantity) Phase Voltage (VAC) 1 2 IEC-C13 (12) IEC-C13 (12) Max Cont. Per Receptacle Per Branch SIDE VIEW AGENCY: CSA Tested to UL RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32 F-131 F (0 C-55 C ) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F-140 F (-20 C - 60 C ) NOTES: 1. Unit Dimensions: 43.2" (1097mm) L x 1.7" (44mm) W x 3.3" (85mm) D 2. Unit Weight: 6.8lbs (3.1kg) 3. Shipping Dimensions: 44.9" (1140mm) L x 2.8" (70mm) W x 6.3" (0mm) D 4. Shipping Weight: 7.7lbs (3.5kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev " (44mm) 2.1 (53mm) 3.3" (85mm) 17
22 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 14 Knurr DI-STRIP " (170mm) 21.3" (540mm) FRONT VIEW 20A branch circuit breaker TOP VIEW 20A branch circuit breaker 1.9" (47mm) L6-30P (2-pole, 3-wire) INPUT POWER BOTTOM VIEW Input Cord Input Plug Phase Voltage (VAC) Max. Cont. 10 ft. (3m) L6-30P OUTPUT POWER Branch Receptacle Type (Qty) Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Branch 1 IEC-C13 (10) / IEC-C19 (2) 1 / / / 20 2 IEC-C13 (10) / IEC-C19 (2) 1 / / / 20 AGENCY: CSA tested to UL RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 21.3" (540mm) L x 6.7" (170mm) W x 1.9" (47mm) D 2. Unit weight: 15 lb. (6.8kg) 3. Shipping dimensions: 22.4" (570mm) L x 11.6" (295mm) W x 6.3" (0mm) D 4. Shipping weight: 18.3 lb. (8.3kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 3 18
23 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 15 Knurr DI-STRIP " [46mm 20A Branch Circuit Breaker Branch 1 20A Branch Circuit Breaker Branch 2 20A Branch Circuit Breaker Branch 3 DI STRIP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (697mm) FRONT VIEW 24.5" (622mm) 0.9" (23mm) 1.7" (44mm) REAR VIEW 3.3" (85mm) INPUT POWER L21-30P (4 pole, 5 wire) Input Cord Input Plug Phase 10 ft. (3m) L21-30P 3 OUTPUT POWER Voltage (VAC) 120/208 Receptacle Type Per Receptacle Type Branch (Quantity) Phase Voltage (VAC) 1 IEC-C19 (2) IEC-C19 (2) IEC-C19 (2) SIDE VIEW Max Cont Max Cont. Per Receptacle Per Branch AGENCY: CSA tested to UL RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive, Storage Temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 27.4" (697mm) L x 1.7" (44mm) W x 3.3" (85mm) D 2. Unit weight: 8 lb. (3.6kg) 3. Shipping dimensions: 64.6" (40mm) L x 2.8" (70mm) W x 6.3" (0mm) D 4. Shipping weight: 9.4 lb. (4.3kg) 5. All wiring is to be in compliance with national and local electric codes Mounting provisions provided. Rev. 3 19
24 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure Knurr DI-STRIP Branch 1 Branch 3 DI STRIP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (44mm) 39.3" (997mm) FRONT VIEW Branch " (322mm) 24.5" (622mm) 2.1" (53mm) REAR VIEW 2.0" (50mm) INPUT POWER L21-20P (4 pole, 5 wire) SIDE VIEW AGENCY: CSA Tested to UL RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32 F-131 F (0 C to 55 C ) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F to 140 F (-20 C to 60 C ) Input Cord Input Plug Phase Voltage (VAC) Max Cont. 10 ft/3.0m L21-20P 3 120/ OUTPUT POWER Branch Receptacle Type (Quantity) Per Receptacle Type Phase Voltage (VAC) Max Cont. Per Receptacle Per Branch NOTES: 1. Unit Dimensions: 39.3" (997mm) L x 1.7" (44mm) W x 2.0" (50mm) D 2. Unit Weight: 5.8 lb. (2.63kg) 3. Shipping Dimensions: 40.4" (1027mm) L x 2.3" (60mm) W x 3.9" (100mm) D 4. Shipping Weight: 6.2 lb. (2.8kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided IEC-C13 (6)/IEC-C19 (2) IEC-C13 (6)/IEC-C19 (2) IEC-C13 (6)/IEC-C19 (2) 1 / 1 1 / 1 1 / / / / / 12 / 12 / Rev. 3 20
25 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 17 Knurr DI-STRIP Branch 3 Branch 2 DI STRIP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (44mm) 51.1" (1297mm) FRONT VIEW 11.9" (301mm) Branch " (934mm) 2.5 (63mm) REAR VIEW 2.0" (50mm) SIDE VIEW INPUT POWER L21-20P (4 Pole, 5 Wire) Input Cord Input Plug Phase Voltage (VAC) Max Cont. 10 ft/3.0m L21-20P 3 120/ AGENCY: CSA Tested to UL RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C ) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F to 140 F (-20 C to 60 C ) OUTPUT POWER Bank Receptacle Type (Quantity) IEC-C13 (9) / IEC-C19 (2) IEC-C13 (9) / IEC-C19 (2) IEC-C13 (9) / IEC-C19 (2) Per Receptacle Type Phase 1 / 1 1 / 1 1 / 1 Voltage (VAC) / / / Max Cont. Per Receptacle Per Bank 12 / 12 / 12 / NOTES: 1. Unit Dimensions: 51.1" (1297mm) L x 1.7" (44mm) W x 2.0" (50mm) D 2. Unit Weight: 7.0 lb. (3.2kg) 3. Shipping Dimensions: 72.0" (1830mm) L x 2.4" (60mm) W x 3.5" (90mm) D 4. Shipping Weight: 7.5 lb. (3.4kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 3 21
26 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 18 Knurr DI-STRIP Branch 3 Branch 1 DI STRIP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (44mm) 39.3" [997mm] FRONT VIEW 39.3" [997mm 12.3" (312mm) Branch " [622mm] 24.5" (622mm) 2.5 (63mm) REAR VIEW 2.0" (50mm) L21-20P (4 Pole, 5 Wire) INPUT POWER Input Cord Input Plug Phase Voltage (VAC) Max Cont. 10 ft/3.0m L21-20P 3 120/ OUTPUT POWER Bank Receptacle Type (Quantity) 5/20R (9) 5/20R (9) 5/20R (9) Per Receptacle Type Phase Voltage (VAC) Max Cont. Per Receptacle Per Bank SIDE VIEW AGENCY: CSA Tested to UL RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C ) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F to 140 F (-20 C to 60 C ) NOTES: 1. Unit Dimensions: 39.3" (997mm) L x 1.7" (44mm) W x 2.0" (50mm) D 2. Unit Weight: 5.7lb. (2.6kg) 3. Shipping Dimensions: 40.4" (1027mm) L x 2.3" (60mm) W x 4.0" (100mm) D 4. Shipping Weight: 6.3lb. (2.85kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 3 22
27 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 19 Knurr DI-STRIP A branch circuit breaker Branch 1 20A branch circuit breaker Branch 2 20A branch circuit breaker Branch 3 1.7" (44mm) DI STR IP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (1297mm) FRONT VIEW 25.7" (652mm) 24.5" (622mm) 0.9" (23mm) 1.8" (46mm) REAR VIEW 3.3" (85mm) INPUT POWER L21-30P (4-pole, 5-wire) Input Cord Input Plug Phase Voltage (VAC) Max. Cont. SIDE VIEW AGENCY: CSA tested to UL RoHS compliant (reduction of hazardous substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C), 5% - 95% RH non-condensing, non-corrosive Storage temperature: -4 F to 140 F (-20 C to 60 C) 10 ft. (3m) L21-30P / OUTPUT POWER Branch Receptacle Type (Qty) Receptacle Type Max. Cont. Phase Voltage (VAC) Per Receptacle Per Branch 1 IEC-C13 (6) / IEC-C19 (2) 1 / / / 20 2 IEC-C13 (6) / IEC-C19 (2) 1 / / / 20 3 IEC-C13 (6) / IEC-C19 (2) 1 / / / 20 NOTES: 1. Unit dimensions: 51.1" (1297mm) L x 1.7" (44mm) W x 3.3" (85mm) D 2. Unit weight: 10.1 lb. (4.6kg) 3. Shipping dimensions: 64.6" (40mm) L x 2.8" (70mm) W x 6.3" (0mm) D 4. Shipping weight: 11.6 lb. (5.25kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 3 23
28 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 20 Knurr DI-STRIP A Branch Circuit Breaker 20A Branch Circuit Breaker 20A Branch Circuit Breaker Branch 1 Branch 2 Branch 3 1.7" (44mm) DI STRIP NA BASIC 120 VAC, 60Hz Input: max. 15A Outlets: max. 15A / " (1597mm) Front View 13.0" (330mm) 49.0" (1245mm) 0.9" (22mm) Rear View 1.8" (46mm) L21-30P (4 Pole, 5 Wire) INPUT POWER Input Cord Input Plug 10ft/3.0m L21-30P 3 120/ OUTPUT POWER Branch Receptacle Type (Quantity) Phase IEC-C13 (9) / IEC-C19 (2) IEC-C13 (9) / IEC-C19 (2) IEC-C13 (9) / IEC-C19 (2) Voltage (VAC) Per Receptacle Type Phase 1 / 1 1 / 1 1 / 1 Voltage (VAC) / / / Max Cont. Max Cont. Per Receptacle Per Branch 12 / / / 20 AGENCY: CSA Tested to UL " RoHS Compliant (Reduction of Hazardous Substances) (85mm) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C ) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F to 140 F (-20 C to 60 C ) NOTES: 1. Unit Dimensions: 62.9" (997mm) L x 1.7" (44mm) W x 3.3" (85mm) D 2. Unit Weight: 11.0lb. (5.0kg) 3. Shipping Dimensions: 72.4" (1840mm) L x 2.8" (70mm) W x 6.3" (0mm) D 4. Shipping Weight: 12.7lb. (5.75kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 3 24
29 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 21 Knurr DI-STRIP " (170mm) 20A Branch Circuit Breaker 20A Branch Circuit Breaker 20A Branch Circuit Breaker 63.0" (00mm) FRONT VIEW 20A Branch Circuit Breaker 20A Branch Circuit Breaker 20A Branch Circuit Breaker REAR VIEW OUTPUT POWER IEC (3 POLE, 4 WIRE, 250VAC, BLUE) INPUT POWER Input Cord Input Plug Phase Voltage (VAC) 10ft/3.0m IEC Branch Receptacle Type (Quantity) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) Phase 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 60 Per Receptacle Type Voltage (VAC) / / / / / / SIDE VIEW Max. Cont. 48 Max. Cont. Per Receptacle Per Branch 12 / / / / / / " (47mm) AGENCY: UL , cul RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32 F-131 F (0 C to 55 C) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit dimensions: 63.0" (00mm) L x 6.7" (170mm) W x 1.9" (47mm) D 2. Unit Weight: 32.8lbs (14.9kg) 3. Shipping Dimensions: 74.0" (1880mm) L x.3" (415mm) W x 6.3" (0mm) D 4. Shipping Weight: 38.4lb. (17.4kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 5 25
30 Knurr DI-STRIP Product Selection Guide - Basic Rack PDUs Figure 22 Knurr DI-STRIP " (170mm) 20A Branch Circuit Breaker 20A Branch Circuit Breaker 20A Branch Circuit Breaker 63" (00mm) FRONT VIEW 20A Branch Circuit Breaker 20A Branch Circuit Breaker 20A Branch Circuit Breaker REAR VIEW INPUT POWER Input Cord Input Plug Phase Voltage (VAC) 10ft/3.0m IEC OUTPUT POWER IEC (3 POLE, 4 WIRE, 250VAC, BLUE) SIDE VIEW Max. Cont " (47mm) AGENCY: UL , cul RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32 F-131 F (0 C to 55 C) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F to 140 F (-20 C to 60 C) Input/ Branch 1/1 1/2 1/3 2/4 2/5 2/6 Receptacle Type (Quantity) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) IEC-C13 (7) / IEC-C19 (1) Per Receptacle Type Phase 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 Voltage (VAC) / / / / / / Max. Cont. Per Receptacle Per Branch 12 / / / / / / 20 NOTES: 1. Unit dimensions: 63.0" (00mm) L x 6.7" (170mm) W x 1.9" (47mm) D 2. Unit Weight: 44.5lb. (20.2kg) 3. Shipping Dimensions: 74.0" (1880mm) L x.3" (415mm) W x 6.3" (0mm) D 4. Shipping Weight: 50lb. (22.7kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Mounting provisions provided Rev. 5 26
31 Liebert MPH Product Selection Guide - Managed Rack PDUs 4.0 LIEBERT MPH PRODUCT SELECTION GUIDE - MANAGED RACK PDUS 4.1 Overview - Managed Rack PDUs The Liebert MPH Managed Rack PDU system delivers power distribution, branch monitoring and receptacle control for IT devices. Liebert MPH Rack PDUs, with remote monitoring and/or control capabilities for power distribution at the load/equipment level, are designed to support the growth in rack electrical needs while meeting the new demands for remote power management. The Liebert MPH monitors electrical attributes of an individual Rack PDU, including real-time remote and (optional) local display of monitoring of aggregate and branch electrical parameters (status, thresholds, alarms) including voltage, amps, kw, and kw-hr. Liebert MPH features include branch load monitoring and control for continuous uptime and minimum disruptions; expandable monitoring interface providing simplified growth management; rugged construction; and the convenience of being factory-installed in the Knurr rack enclosure system. The Liebert MPH includes an input power cord with appropriate input plug connection and hydraulic-magnetic branch rated overload protection as appropriate; basic rack mounting provisions are also provided. Liebert MPH Managed Rack PDUs are available in rack mount and vertical zero-u form factors and are painted black. Liebert MPH Managed Rack PDUs / Liebert MPH-NB Systems (Branch Monitoring Only) Liebert MPH-NB series Rack PDUs provide local and remote monitoring of individual PDU volts, amps, watts, and kilowatt-hours. Liebert MPH Managed Rack PDUs / Liebert MPH-NC (Monitoring & Receptacle Control) Liebert MPH-NC series power strips provide the same features and functionality as the Liebert MPH-NB series with the additional capability of remote on/off control of individual receptacles. Local receptacle power on-off status is provided through an LED display. Liebert MPH Managed Rack PDUs ALL Liebert MPH Systems All Liebert MPH systems are provided with a factory-integrated Liebert RPC (Rack PDU Card RPC-1000) that provides Web-based remote monitoring via a direct IP network connection, Rack PDU Array interface connection to three additional Liebert MPH or Liebert MPX systems to allow viewing of up to four Rack PDUs on a single IP connection, an environmental sensor port, and a port for connection to the optional local display. Local display monitoring is provided via the optional RPC BDM (Basic Display Module) and integrated audible alarm. See Adaptive Rack PDU Optional Accessories for further details. Each Liebert MPH unit is provided with basic rack mounting provisions to meet a range of installation needs. The Liebert MPH fits most standard 600mm width network equipment rack enclosures. Product fit should be confirmed for each application. 27
32 Liebert MPH Product Selection Guide - Managed Rack PDUs 4.2 Specifications - Liebert MPH Table 3 Specifications - Liebert MPH Part Number Branch Monitoring Voltage (VAC) INPUT Max. Continuous kw* Phase Plug OUTPUT Receptacle/Socket Configuration Form Factor MPH-NBR09AXXC NEMA L5-20P (9) NEMA 5-20R T-Slot Rack mount MPH-NBV27AXXC NEMA L5-20P (27) NEMA 5-20R T-Slot Vertical MPH-NBR09AXXD NEMA L5-30P (9) NEMA 5-20R T-Slot Rack mount MPH-NBV27AXXD NEMA L5-30P (27) NEMA 5-20R T-Slot Vertical MPH-NBR09NXXE NEMA L6-20P (9) IEC-C13 Rack mount MPH-NBV27NXXE NEMA L6-20P (27) IEC-C13 Vertical MPH-NBR09NXXF NEMA L6-30P (9) IEC-C13 Rack mount MPH-NBV27NXXF NEMA L6-30P (27) IEC-C13 Vertical MPH-NBV27NOXF NEMA L6-30P (21) IEC-C13 & (6) IEC-C19 Vertical MPH-NBV27NXXJ NEMA L15-30P (27) IEC-C13 Vertical MPH-NBV27NOXJ NEMA L15-30P (21) IEC-C13 & (6) IEC-C19 Vertical MPH-NBV27AMXH30 120/ NEMA L21-30P (15) IEC-C13, (6) NEMA 5-20 T-slot & Vertical (6) IEC-C19 MPH-NBV27AXXH30 120/ NEMA L21-30P (27) NEMA 5-20R T-Slot Vertical MPH-NBV27ANXH30 120/ NEMA L21-30P (21) IEC-C13 & (6) NEMA 5-20R T-Slot Vertical MPH-NBV27NXXH30 120/ NEMA L21-30P (27) IEC-C13 Vertical MPH-NBV27NOXH30 120/ NEMA L21-30P (21) IEC-C13 & (6) IEC-C19 Vertical Receptacle Control MPH-NCR09AXXC NEMA L5-20P (9) NEMA 5-20R T-Slot Rack mount MPH-NCV27AXXC NEMA L5-20P (27) NEMA 5-20R T-Slot Vertical MPH-NCR09AXXD NEMA L5-30P (9) NEMA 5-20R T-Slot Rack mount MPH-NCV27AXXD NEMA L5-30P (27) NEMA 5-20R T-Slot Vertical MPH-NCR09NXXE NEMA L6-20P (9) IEC-C13 Rack mount MPH-NCV27NXXE NEMA L6-20P (27) IEC-C13 Vertical MPH-NCR09NXXF NEMA L6-30P (9) IEC-C13 Rack mount MPH-NCV27NXXF NEMA L6-30P (27) IEC-C13 Vertical MPH-NCV27NOXF NEMA L6-30P (21) IEC-C13 & (6) IEC-C19 Vertical MPH-NCV27NXXJ NEMA L15-30P (27) IEC-C13 Vertical MPH-NCV27NOXJ NEMA L15-30P (21) IEC-C13 & (6) IEC-C19 Vertical (15) IEC-C13, MPH-NCV27AMXH30 120/ NEMA L21-30P (6) NEMA 5-20 T-slot & Vertical (6) IEC-C19 MPH-NCV27AXXH30 120/ NEMA L21-30P (27) NEMA 5-20R T-Slot Vertical MPH-NCV27ANXH30 120/ NEMA L21-30P (21) IEC-C13 & (6) NEMA 5-20R T-Slot Vertical MPH-NCV27NXXH30 120/ NEMA L21-30P (27) IEC-C13 Vertical MPH-NCV27NOXH30 120/ NEMA L21-30P (21) IEC-C13 & (6) IEC-C19 Vertical All input cords are 10 ft. (3m) in length. * Formulas used to calculate the kw: For single-phase: input voltage x max continuous amps = watts For three-phase: input voltage x max continuous amps x 1.73 = watts 28
33 4.3 Model Number Configuration - Liebert MPH Example: MPH N B R 09 AX XC 30 Liebert MPH Product Selection Guide - Managed Rack PDUs Prefix: MPH Region: N = North American Type: B = Branch Monitoring C = Controlled Receptacles Mounting: V = Vertical R = Rack mount Output Power: Quantity Receptacles (Total): 09 or 27 Receptacle Type(s) 2 characters (each set): A = 5-20R T-Slot N = IEC-C13 O = IEC-C19 Note: Second character indicates a second receptacle type (X if no additional type chosen) Input Power: Plug Type: First character = X Second character: C=L5-20P D=L5-30P E=L6-20P F=L6-30P H = L21-30P J = L15-30P Cord Length: 30 = 3.0m (10 ft.) 29
34 Liebert MPH Product Selection Guide - Managed Rack PDUs 4.4 Managed Rack PDU Optional Cord Sets and Cable Restraints Output Cord Sets Output cord sets are available to support conversion of Rack PDU power output receptacles to alternative power output connections and to support Rack PDU output expansion capabilities. Conversion of power output connections can be provided on Rack PDUs with IEC-C19 receptacles. The output cord set for these systems includes an IEC-C20 plug to connect to the IEC-C19 receptacle, a 3 ft. (1m) power cord and receptacle to connect to user equipment. Available receptacles include: IEC-C13 to connect to IEC-C14 equipment plugs and IEC-C19 to connect to NEMA L6-20P equipment plugs. Input Cord Sets Input cord sets are available to support conversion of Rack PDU power input connections to alternative power input connections. Conversion of power input can be provided on Rack PDUs with L5-20P plug connections. The input cord set includes an L5-20R receptacle to connect to the L5-20P Rack PDU plug, a 1 ft. (0.3m) power cord and a 5-20P plug. Cable Restraints (Liebert MPH - Vertical Systems) Cable restraints are available to secure user equipment power cord connections to IEC-C13 receptacles. The Liebert MPH supports all vertical-mount models with IEC-C13 receptacles or a combination of IEC-C13 plus IEC-C19 receptacles. The cable restraint system includes three tie-down brackets for receptacle groups along with cable ties to secure individual input user equipment power cables. Table 4 Cord sets and cable restraints - Liebert MPH Cord Sets and Cable Restraints Output Cord Sets - Power Output Conversion G5 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 3.3 ft. (1m) G6 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 10 ft. (3m) G9 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 3.3 ft. (1m) G10 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 10 ft. (3m) Input Cord Sets - Power Input Conversion G12 Input Cord Set - Power Input Conversion - L5-20P to 5-20P, 1 ft. (0.3m) Cable Restraints IEC-C13 (Liebert MPH - Vertical Systems) 11858KIT Cable Restraints - MPH Vertical Systems with IEC-C13 receptacles 30
35 4.5 Dimensional Drawings - Managed Rack PDUs Liebert MPH Product Selection Guide - Managed Rack PDUs Figure 23 Liebert MPH rack mount power strip Liebert MPH Power Distribution 1.7" [44mm PN: RPC-1000 HID Audible Alarm Silence FRONT VIEW 18.3" (465mm) RPC Communication Card Circuit Breaker 20 Amp 1.2" (32mm) 20A Input Breaker Input Plug REAR VIEW Output Receptacles 0.2" (6mm) 17.2" (438mm) L5-20P (2 Pole, 3 Wire) 7.0" (178mm) INPUT POWER Input Cord Input Plug Phase R (9) 1 Voltage (VAC) 10ft/3.0m L5-20P OUTPUT POWER Branch Receptacle Type (Quantity) Per Receptacle Type Phase TOP VIEW 20 Voltage (VAC) Per Receptacle 120 Max Cont. Max Cont. MPH-NCR09AXXC30 Rev. 3 Per Branch 20 AGENCY: UL/C-UL Listed to UL RoHS Compliant (Reduction of Hazardous Substances) ENVIROMENTAL: Operating: 32 F-131 F (0 C-55 C) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F-140 F (-20 C to 60 C) NOTES: 1. Unit Dimensions: 1.7" H x 7.0" D x 17.2" W (44mm x 178mm x 438mm) 2. Unit Weight: 7.5lb. (3.4kg) 3. Shipping Dimensions: 22.0" H x 9.0" D x 24.1" W (559mm x 228mm x 612mm) 4. Shipping Weight: 8.5lb. (3.9kg) 5. All wiring is to be in compliance with national and local electric codes
36 Liebert MPH Product Selection Guide - Managed Rack PDUs Figure 24 Liebert MPH vertical power strip Branch 3 (9) 5-20R Branch 3 (9) 5-20R Branch 3 (9) 5-20R RPC Communication Card Branch 3 Branch 2 Branch 1 Branch 3 Branch 2 Branch 1 Circuit Breaker Circuit Breaker Circuit Breaker 20 Ampere 20 Ampere 20 Ampere Liebert MPH P ower Distribution PN: RPC-1000 HID 20A Branch Circuit Breakers FRONT VIEW 68.1" (1730mm) 1.9" (50mm) 3.4 (86mm) 3.4 (86mm) 12.3 (312mm) 12.3 (312mm) 0.2" (6mm) 1.2" (32mm) 0.99 (25mm) 9.2" (235mm) REAR VIEW Toolless Mounting Button (See Note 6) Vertical Mounting Bracket (See Note 6) 3.1" (80mm) INPUT POWER Input Cord Input Plug 10 ft/3.0m OUTPUT POWER Branch L5-20P Receptacle Type (Quantity) Phase 1 2.2" (57mm) Voltage (VAC) 120 Per Receptacle Type Phase Voltage (VAC) L5-20P (2 Pole, 3 Wire) SIDE VIEW Max Cont. 20 Max Cont. Per Receptacle Per Branch AGENCY: UL/C-UL Listed to UL RoHS Compliant (Reduction of Hazardous Substances) ENVIRONMENTAL: Operating: 32 F to 131 F (0 C to 55 C) non-condensing, non-corrosive, 5% - 95% RH Storage Temperature: -4 F to 140 F (-20 C to 60 C) NOTES: 1. Unit Dimensions: 68.1" (1730mm) H x 3.1" (80mm) D x 1.9" (50mm) W 2. Unit Weight: 18lb. (8.2kg) 3. Shipping Dimensions: 72.2" (1962mm) H x 6.2" (159mm) D x 10.7" (273mm) W 4. Shipping Weight: 20lb. (9.1kg) 5. All wiring is to be in compliance with national and local electric codes. 6. Only one mounting option required to be used at a time. Vertical mounting brackets and toolless buttons shown together for reference only R (9) 5-20R (9) 5-20R (9) MPH-NCV27AXXC30 Rev
37 Liebert MPX - Adaptive Rack PDUs 5.0 LIEBERT MPX - ADAPTIVE RACK PDUS 5.1 Overview - Adaptive Rack PDUs The Liebert MPX Adaptive Rack PDU system delivers break-through flexibility, availability and total cost of ownership. The Liebert MPX enables users to respond to and manage changing rack power and management environments. The Liebert MPX provides users the ability to size their Rack PDU system to support initial requirements and then adapt as connectivity, capacity and/or functionality needs change. The Liebert MPX is based on a patent-pending design built on a power / communication bus and input/output power module strategy. The Liebert MPX Adaptive Rack PDU is composed of several key building blocks and support modules. The Liebert MPX is built on the MPX PRC (Power Rail Chassis) that distributes power and communications to all support modules, acts as a backplane to mount support modules and offers provisions to physically mount the Liebert MPX in a network rack. Input power is connected and delivered to the Liebert MPX system via the MPX PEM (Power Entry Module). Output power connectivity and communications management level is defined by the MPX BRM (Branch Receptacle Modules). MPX BRM power connectivity includes NEMA receptacles and IEC sockets. MPX BRM communications include Branch Monitoring and Receptacle Management versions. Network communications, sensor and/or local display interface are provided by the Liebert RPC (Rack PDU Card) that mounts in the MPX PEM. The Liebert RPC provides connection to an optional RPC BDM (Basic Display Module) for local status / alarm viewing. Module versions for North American and European applications are available. The Liebert MPX is provided as separate ship-loose modules for user on-site configuration. The Liebert MPX is designed for simple and quick configuration and reconfiguration. Preconfigured systems are available as an Special Feature Authorization (SFA) when ordered as factory installed in Knurr rack enclosure systems. The major Liebert MPX system components are described in the following sections: MPX PRC (Power Rail Chassis) MPX PEM (Power Entry Module) and MPX IPC (Input Power Cord) MPX BRM (Branch Receptacle Module) 33
38 Liebert MPX - Adaptive Rack PDUs Figure 25 Liebert MPX 1880 and 1035 models and components MPX BRM Liebert RPC MPX PEM, Variable Capacity Liebert MPX, 1035mm Liebert PRC chassis MPX PEM, Fixed Capacity Liebert MPX, 1880mm Liebert PRC chassis MPX IPC RPC BDM 34
39 5.2 MPX PRC (Power Rail Chassis) Liebert MPX - Adaptive Rack PDUs The MPX PRC distributes power and communications to the installed Liebert MPX modules. The MPX PRC supports both single-phase power input up to 20A and three-phase up to 60A. It includes provisions to mount and secure an input power module (MPX PEM) and output receptacle modules (MPX BRM). It is available in lengths to accommodate typical 23U or 42U network racks: 1035mm (40.75 in.) for 23U and 1880mm (74 in.) for 42U. The MPX PRC includes zero-u mounting provisions that accommodate most rack designs. The MPX PRC is provided with cover / spacers to assist users with positioning for future MPX BRM module additions. Figure 26 MPX PRC (Power Rail Chassis) FRONT SIDE Section of MPX PRC Power Bus REAR SIDE Section of MPX PRC Communication Bus T-slots in the back of the MPX PRC (Power Rail Chassis) accept spring nuts for easy mounting Module Connector Slot 35
40 5.3 MPX PEM (Power Entry Module) and MPX IPC (Input Power Cord) Liebert MPX - Adaptive Rack PDUs The MPX PEM provides input power to the Liebert MPX system and includes provisions for addition of the Liebert RPC (Rack PDU Card) to support remote and local communications. The MPX PEM is available in two versions: Variable Capacity and Fixed Capacity. The MPX PEM Variable Capacity version allows the user to select and change power input via different MPX IPCs. The MPX IPC includes cord, MPX PEM connector, and input plug. The MPX IPC is available in multiple versions supporting up to 30 amps including single-phase North American 120VAC and 208VAC and three-phase North American 208/120VAC connections. The MPX PEM Fixed Capacity version supports rated input capacities from 40 up to 60 amps with fixed cord and plug connections. All MPX PEMs include an audible over current alarm with local reset. One MPX PEM is required per Liebert MPX Rack PDU. Variable Capacity MPX PEMs are 220mm in length for application on both short (1035mm) and standard (1880mm) MPX PRC systems. Fixed Capacity systems are 266mm in length for application on standard (1880mm) MPX PRCs. 5.4 MPX BRM (Branch Receptacle Module) The MPX BRM provides output power distribution to user load equipment and remote management / monitoring of that equipment. The MPX BRM includes output receptacles (NEMA and IEC) and is overload-protected. The MPX BRM is available in two versions: Branch Monitoring and Receptacle Management. The MPX BRM Branch Monitoring version supports monitoring of its aggregate branch electrical and energy parameters (status, thresholds, and alarms) including voltage, amps, kw, and kw-hr. The MPX BRM Receptacle Management version supports monitoring of individual receptacle electrical and energy parameters (status, thresholds, and alarms) including voltage, amps, kw and kw-hr and supports on-off power control of individual receptacles, along with the aggregate branch monitoring provided on MPX BRM Branch Monitoring systems. MPX BRMs are hot-swappable to allow user installation without powering down the Liebert MPX system. Each MPX BRM includes a display that automatically assigns and displays a Branch identification number to the MPX BRM when added to an active Liebert MPX system. Each MPX BRM is overload-protected by 20 Amp branch-rated hydraulic magnetic circuit breakers that support UL60950 requirements. The breakers are protected from inadvertent tripping by requiring tool insertion to manually open and from accidental impact damage by a protection body/cover. MPX BRMs are offered in line-to-line and line-to-neutral power configurations. These configurations support different power input requirements and provide support for load balancing for three-phase input power systems. Up to three (3) MPX BRMs can be deployed on a Liebert MPX system utilizing the 1035mm MPX PRC for typical 23U racks and up to six (6) MPX BRMs for systems utilizing the 1880mm MPX PRC for typical 42U racks. All MPX BRMs are 266mm in length. 36
41 Liebert MPX - Adaptive Rack PDUs 5.5 Adaptive Rack PDU Optional Accessories Cord Sets and Cable Restraints Output Cord Sets Output cord sets are available to support conversion of Rack PDU power output receptacles to alternative power output connections and to support Rack PDU output expansion capabilities. Conversion of power output connections can be provided on Rack PDUs with IEC-C19 receptacles. The output cord set for these systems includes an IEC-C20 plug to connect to the IEC-C19 receptacle, a 3 ft. (1m) power cord and receptacle to connect to user equipment. Available receptacles include: IEC-C13 to connect to IEC-C14 equipment plugs and IEC-C19 to connect to NEMA L6-20P equipment plugs. Cable Restraints (Liebert MPX Systems) Cable restraints are available to secure user equipment power cord connections to IEC-C13 receptacles. The Liebert MPX supports all models of the MPX BRM with IEC-C13 receptacles and includes individual cable restraint clips to support individual receptacles. Twelve restraint clips are provided per option. The Liebert MPX cable restraint supports most IEC-C14 plugs that connect to the IEC-C13 receptacles. Cord Sets and Cable Restraints Output Cord Sets - Power Output Conversion G5 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 3 ft. (1m) G6 Output Cord Set - Power Output Conversion - IEC-C20 to IEC-C13, 10 ft. (3m) G9 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 3 ft. (1m) G10 Output Cord Set - Power Output Conversion - IEC-C20 to NEMA L6-20R, 10 ft. (3m) Cable Restraints IEC-C13 (Liebert MPX Systems) Cable Restraints - MPX BRM with IEC-C13 receptacles (Set of 12) Liebert RPC (RPC-1000) and Accessories The Liebert RPC (Rack PDU Card) is a network interface card that provides network connectivity to the Liebert Rack PDU family of products. The Liebert RPC can be installed in Adaptive and Managed versions of Liebert Rack PDUs to provide network monitoring and control capabilities. The Liebert RPC is a factory-installed standard feature of the Liebert MPH; it is an option for the Liebert MPX. In addition, the Liebert RPC serves as the integration point for several rack accessory products. Available options that connect to the card include the RPC BDM (Basic Display Module) and a temperature/humidity sensor. 37
42 5.5.3 Part Numbers for Liebert RPC and Accessories Liebert MPX - Adaptive Rack PDUs Liebert RPC (Rack PDU Card): RPC-1000 RPC BDM (Basic Display Module): RPC-BDM-1000 Liebert SN Integrated Environmental Sensors: SN-Z01 - Single Temperature Probe; 12 ft. (3.66m) length cable SN-Z02 - Three Temperature Probes; 17 ft. (5.18m) length cable SN-Z03 - Three Temperature Probes and Single Humidity Probe; 17 ft. (5.18m) length cable Liebert SN Modular Environmental Sensors: SN-T - Single Temperature Probe (1 probe) SN-TH - Single Temperature Probe and Single Humidity Probe (2 probes) SN-2D - Door Switch, 2 inputs (1 probe) SN-3C - Digital Input, 3 inputs (1 probe) Ports on the Liebert RPC Figure 27 shows the four individual ports on the Liebert RPC. Each port is designed for only one type of connection. See the Liebert RPC user manual, SL-20825, for details on using these ports. Figure 27 Liebert RPC ports External Sensor port Display port Expansion/Management port LAN port 38
43 Liebert MPX - Adaptive Rack PDUs Liebert RPC Capabilities and Benefits The Liebert RPC offers the following capabilities and benefits: Web Support The Liebert RPC delivers Web management and control to Liebert Rack PDU equipment. All authorized users will be able to view status information on their network. SNMP Support The Liebert RPC enables SNMP management of Liebert Rack PDU equipment. To integrate the card into an SNMP implementation, compile the Liebert Global Products MIB on your Network Management System (NMS). The Liebert Global Products MIB can be downloaded from: Liebert Nform Utilizing the SNMP and Web technologies built into the Liebert RPC, Liebert Nform will centrally manage event notifications, access critical system information and manage the power delivered to your critical devices. A downloadable edition is available online at: nform.liebert.com Liebert SiteScan Web The Liebert RPC integrates with Liebert SiteScan Web software to monitor and analyze trends to ensure high-availability operation of critical facilities. For more information on Liebert SiteScan Web, visit the Web page at: sitescan.liebert.com 39
44 Liebert MPX - Adaptive Rack PDUs RPC BDM Basic Display Module The RPC BDM is an optional device with an LCD for local viewing of status and alarms of up to four Liebert MPX or Liebert MPH PDUs. It connects to Liebert RPC with a factory-supplied cable that is 6.5 ft. (2m) long. The portable unit can be mounted on a wall for viewing particular units. The RPC BDM provides local display of electrical status for all connected Liebert MPX (and Liebert MPH) systems, MPX BRMs and individual receptacles, if the PDU version permits it. Information is accessed via a navigation switch on the RPC BDM. For model number and other details, refer to Part Numbers for Liebert RPC and Accessories and the Liebert RPC user manual, SL-20825, available at the Liebert Web site: Figure 28 RPC BDM Jog Wheel on Top of Unit to Navigate Display Communication Port on Side of Unit Connects to Liebert RPC RPC BDM Temperature/Humidity Sensor A temperature/humidity sensor is available to monitor conditions in the rack. The sensor mounts without tools. It connects to the Liebert RPC with a factory-supplied Ethernet cable and can be monitored over a network. Figure 29 Temperature/humidity sensor Sensor support Tool-less fastener Sensor Support base Sensor installed in rack Sensor Knurr frame member 40
45 Liebert MPX System Product Selection Guide 6.0 LIEBERT MPX SYSTEM PRODUCT SELECTION GUIDE 6.1 STEP 1 - Select an MPX PRC (Quantity x 1) To select an MPX PRC (Power Rail Chassis), refer to: Specifications - MPX PRC MPXPRC-V1035XXX: Input: Rack Fit: MPXPRC-V1880XXX: Input: Rack Fit: Max 8.6 kw, limited to 3 MPX BRM modules Single-Phase and Three-Phase 5-wire / Amp / 120/208VAC Typical 23U, most 600mm wide Max 17.2 kw, limited to 6 MPX BRM modules Single-Phase and Three-Phase 5-wire / Amp / 120/208VAC Typical 42U, most 600mm wide Model Number Configuration - MPX PRC Example: MPXPRC-V1035XXX Prefix: Mounting: MPXPRC V = Vertical Length: 1035 = Short (40.75"; 1035mm) 1880 = Standard (74"; 1880mm) Placeholder: XXX Liebert MPX with 1035mm Liebert PRC chassis Liebert MPX with 1880mm Liebert PRC chassis 41
46 6.2 STEP 2 - Select an MPX PEM / MPX IPC (Quantity x 1) Liebert MPX System Product Selection Guide To select an MPX PEM (Power Entry Module) and an MPX IPC (Input Power Cord) for a Variable Capacity MPX PEM system refer to: The appropriate table in System Selection Guide for the MPX PEM (Power Entry Module): Table 5 - Selections for Power Entry Module MPXPEM-NVAXXAXX Table 6 - Selections for Power Entry Module MPXPEM-NHBXXV30 Table 7 - Selections for Power Entry Module MPXPEM-NHBXXX30 Table 8 - Selections for Power Entry Module MPXPEM-NHBXXW30 The following information: Input Power MPX PEM Selection MPX IPC Input Plug 120VAC / 1-Phase / 30 Amp MPXPEM-NVAXXAXX MPXIPC-NXD30XXX L5-30P 208VAC / 1-Phase / 30 Amp MPXPEM-NVAXXAXX MPXIPC-NXF30XXX L6-30P 208VAC / 3-Phase / 30 AMP MPXPEM-NVAXXAXX MPXIPC-NXJ30XXX L15-30P 120/208VAC / 3-Phase / 20 Amp MPXPEM-NVAXXAXX MPXIPC-NXG30XXX L21-20P 120/208VAC / 3-Phase / 30 Amp MPXPEM-NVAXXAXX MPXIPC-NXH30XXX L21-30P Specifications - MPX PEM MPX PEM (Power Entry Module) MPXPEM-NVAXXAXX MPXPEM-NHBXXV30 MPXPEM-NHBXXX30 MPXPEM-NHBXXW30 Power Entry Module - Variable Capacity, North American, 120 or 208VAC single-phase and/or VAC three-phase input up to 30Amp Power Entry Module - Fixed Capacity, North American, VAC, three-phase 4-wire (L-L-L-G), 50Amp input, CS8365C plug, 10 ft. (3m) cord Power Entry Module - Fixed Capacity, North American, VAC, three-phase 4-wire (L-L-L-G), 60Amp input, IEC60309 Pin-Sleeve plug, 10 ft. (3m) cord Power Entry Module - Fixed Capacity, North American, 120/208VAC, three-phase 5-wire (L-L-L-N-G), 60Amp input, IEC60309 Pin-Sleeve plug, 10 ft. (3m) cord Model Number Configuration - MPX PEM Example: MPXPEM-NVAXXAXX Prefix: Region: MPXPEM N = North American Type: V = Variable Capacity H = Fixed Capacity Size: A = Base (220mm) Variable Capacity version B = Standard (266mm) Fixed Capacity version Communications: X = Future Use Input Power: Available Capacity or Plug Type: XA = 30 amps XV = 50 amps, 4-wire (CS8365C) XX = 60 amps, 4-wire (IEC60309) XW = 60 amps, 5-wire (IEC60309) Cord Length: XX = No integrated cord (Requires MPX IPC) 30 = 3.0m (10 ft.) MPX PEM, Fixed Capacity MPX PEM, Variable Capacity 42
47 Liebert MPX System Product Selection Guide Specifications - MPX IPC (MPX PEM Variable Capacity Systems ONLY) MPX IPC (Input Power Cord) 120VAC Single-Phase Input / Output Input Power Cord - North American, 30Amp - 120VAC - Single-Phase; MPXIPC-NXD30XXX NEMA L5-30P Locking plug; 10 ft. (3m) length cord 208VAC Single-Phase Input / Output Input Power Cord - North American, 30Amp VAC - Single-Phase; MPXIPC-NXF30XXX NEMA L6-30P Locking plug; 10 ft. (3m) length cord 208VAC Three-Phase Input / 208VAC Single-Phase Output Input Power Cord - North American, 30Amp VAC - Three-Phase, 4-wire; MPXIPC-NXJ30XXX NEMA L15-30P Locking plug; 10 ft. (3m) length cord 208VAC Three-Phase Input / 120/208VAC Single-Phase Output Input Power Cord - North American, 20Amp - 120/208VAC - Three-Phase; MPXIPC-NXG30XXX NEMA L21-20P Locking plug; 10 ft. (3m) length cord Input Power Cord - North American, 30Amp - 120/208VAC - Three-Phase; MPXIPC-NXH30XXX NEMA L21-30P Locking plug; 10 ft. (3m) length cord Model Number Configuration - MPX IPC (MPX PEM Variable Capacity Systems ONLY) Example: MPXIPC-NXG30XXX Prefix: Region: MPXIPC N = North American Input Power and Connection: Plug Type: XD = L5-30P XF = L6-30P XJ = L15-30P XG = L21-20P XH = L21-30P Cord Length: 30 = 3.0m (10 ft.) Placeholder: XXX MPX PEM, Variable Capacity MPX IPC 43
48 Liebert MPX System Product Selection Guide 6.3 STEP 3 - Select an MPX BRM To select an MPX BRM (Branch Receptacle Module), refer to: The appropriate table in System Selection Guide for the MPX PEM (Power Entry Module): Table 5 - Selections for Power Entry Module MPXPEM-NVAXXAXX Table 6 - Selections for Power Entry Module MPXPEM-NHBXXV30 Table 7 - Selections for Power Entry Module MPXPEM-NHBXXX30 Table 8 - Selections for Power Entry Module MPXPEM-NHBXXW30 The following MPX BRM quantity definitions: MPX PRC selected Single-Phase Input Three-Phase Input MPXPRC-V1035XXX 3 MPX BRM modules maximum 1 x BRM per Lx-Lx* (total 3 max) MPXPRC-V1035XXX 6 MPX BRM modules maximum 2 x BRM per Lx-Lx* (total 6 max) * Required for phase load balancing If needed, refer to the MPX BRM specifications in Table 9 Model Number Configuration - MPX BRM Example: MPXBRM-NRBD4O31 Prefix: Region: MPXBRM N = North American Type: B = Branch Monitoring R = Receptacle Management Size and OL Protection: Size: B = Standard (266mm) Voltage Rating and OL Protection: A = 120V/20A D = V/20A Output Power: Quantity Receptacles: 4, 6 Receptacle Type: A = 5-20R T-slot N = IEC-C13 O = IEC-C19 Phase Configuration: 1N = L1-N 2N = L2-N 3N = L3-N 12 = L1-L2 23 = L2-L3 31 = L3-L1 MPX BRM 44
49 Liebert MPX System Product Selection Guide 6.4 STEP 4 - Select Communication Options Choose from the following options for the Liebert MPX: Liebert RPC (Rack PDU Card) part number: RPC-1000 RPC BDM (Basic Display Module) part number: RPC-BDM-1000 Liebert SN Integrated and Modular Environmental Sensor part numbers: Integrated Sensors SN-Z01 - Single Temperature Probe; 12 ft. (3.66m) length cable SN-Z02 - Three Temperature Probes; 17 ft. (5.18m) length cable SN-Z03 - Three Temperature Probes and Single Humidity Probe; 17 ft. (5.18m) length cable Modular Sensors SN-T - Single Temperature Probe (1 probe) SN-TH - Single Temperature Probe and Single Humidity Probe (2 probes) SN-2D - Door Switch, 2 inputs (1 probe) SN-3C - Digital Input, 3 inputs (1 probe) The Liebert RPC is required for the other two options, the RPC BDM and Liebert SN integrated sensor. RPC BDM Liebert RPC Liebert SN (Integrated Sensor) Liebert SN (Modular Sensor) 45
50 6.5 System Selection Guide Table 5 Liebert MPX System Product Selection Guide Use the appropriate table as a guide to select components that are compatible with each MPX PEM: Table 5 - Selections for Power Entry Module MPXPEM-NVAXXAXX Table 6 - Selections for Power Entry Module MPXPEM-NHBXXV30 Table 7 - Selections for Power Entry Module MPXPEM-NHBXXX30 Table 8 - Selections for Power Entry Module MPXPEM-NHBXXW30 MPX PEM Part Number MPXPEM-NVAXXAXX* Selections for Power Entry Module MPXPEM-NVAXXAXX Module Voltage 120/208 or * No fixed cord (requires MPX IPC) Compatible MPX PRC for given MPX PEM: Voltages Supported Max. Continuous Input Connection Variable Max. Continuous Max. # MPX BRMs Supported Input Phases Single-Phase or Three-Phase depending on the MPX IPC selection Phase Configuration Module Length (mm) 220 Overall Length MPXPRC-V1035XXX 120/208 3 Single-Phase 1035mm, 23U MPXPRC-V1880XXX or & Three-Phase 1880mm, 42U Compatible MPX IPC for given MPX PEM: Voltages Supported Max. Continuous Input Plug Phase Configuration Cord Length ft. (m) MPXIPC-NXD30XXX NEMA L5-30P L1-N-G 10 (3.0) Compatible MPX BRM for given MPX IPC: Module Voltage Branch Max. Continuous Quantity & Receptacle Type Output Phase Configuration Module Length (mm) Branch Monitoring MPXBRM-NBBA6A1N 120V 20 (6) NEMA 5-20R L1-N 266 Receptacle Management MPXBRM-NRBA6A1N 120V 20 (6) NEMA 5-20R L1-N 266 Max. Continuous Cord Length ft. (m) Compatible MPX IPC Voltages Phase for given MPX PEM: Supported Input Plug Configuration MPXIPC-NXF30XXX NEMA L6-30P L1-L2-G 10 (3.0) Compatible MPX BRM for given MPX IPC: Branch Monitoring Module Voltage Branch Max. Continuous Quantity & Receptacle Type Output Phase Configuration Module Length (mm) MPXBRM-NBBD6N V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L1-L2 266 Receptacle Management MPXBRM-NRBD6N V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L1-L
51 Table 5 Selections for Power Entry Module MPXPEM-NVAXXAXX (continued) Compatible MPX IPC for given MPX PEM: Voltages Supported Max. Continuous Liebert MPX System Product Selection Guide Input Plug Phase Configuration Cord Length ft. (m) MPXIPC-NXJ30XXX NEMA L15-30P L1-L2-L3-G 10 (3.0) Compatible MPX BRM for given MPX IPC: Module Voltage Branch Max. Continuous Quantity & Receptacle Type Output Phase Configuration Module Length (mm) Branch Monitoring MPXBRM-NBBD6N V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L3-L1 266 Receptacle Management MPXBRM-NRBD6N V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NRBD6N V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L3-L1 266 Compatible MPX IPC for given MPX PEM: Voltages Supported Max. Continuous Input Plug Phase Configuration Cord Length ft. (m) MPXIPC-NXG30XXX 120/ NEMA L21-20P L1-L2-L3-N-G 10 (3.0) Compatible MPX BRM for given MPX IPC: Branch Monitoring Module Voltage Branch Max. Continuous Quantity & Receptacle Type Output Phase Configuration Module Length (mm) MPXBRM-NBBA6A1N 120V 20 (6) NEMA 5-20R L1-N 266 MPXBRM-NBBA6A2N 120V 20 (6) NEMA 5-20R L2-N 266 MPXBRM-NBBA6A3N 120V 20 (6) NEMA 5-20R L3-N 266 MPXBRM-NBBD6N V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L3-L1 266 Receptacle Management MPXBRM-NRBA6A1N 120V 20 (6) NEMA 5-20R L1-N 266 MPXBRM-NRBA6A2N 120V 20 (6) NEMA 5-20R L2-N 266 MPXBRM-NRBA6A3N 120V 20 (6) NEMA 5-20R L3-N 266 MPXBRM-NRBD6N V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NRBD6N V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L3-L
52 Table 5 Selections for Power Entry Module MPXPEM-NVAXXAXX (continued) Compatible MPX IPC for given MPX PEM: Voltages Supported Max. Continuous Liebert MPX System Product Selection Guide Input Plug Phase Configuration Cord Length ft. (m) MPXIPC-NXH30XXX 120/ NEMA L21-30P L1-L2-L3-N-G 10 (3.0) Compatible MPX BRM for given MPX IPC: Module Voltage Branch Max. Continuous Quantity & Receptacle Type Output Phase Configuration Module Length (mm) Branch Monitoring MPXBRM-NBBA6A1N 120V 20 (6) NEMA 5-20R L1-N 266 MPXBRM-NBBA6A2N 120V 20 (6) NEMA 5-20R L2-N 266 MPXBRM-NBBA6A3N 120V 20 (6) NEMA 5-20R L3-N 266 MPXBRM-NBBD6N V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L3-L1 266 Receptacle Management MPXBRM-NRBA6A1N 120V 20 (6) NEMA 5-20R L1-N 266 MPXBRM-NRBA6A2N 120V 20 (6) NEMA 5-20R L2-N 266 MPXBRM-NRBA6A3N 120V 20 (6) NEMA 5-20R L3-N 266 MPXBRM-NRBD6N V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NRBD6N V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L3-L
53 Liebert MPX System Product Selection Guide Table 6 Selections for Power Entry Module MPXPEM-NHBXXV30 MPX PEM Part Number Module Voltage Max. Continuous MPXPEM-NHBXXV V Input Connection CS83665C 3-PH, 4-Wire Input Phases Module Length (mm) L1-L2-L3-G 266 Compatible MPX PRC for given MPX PEM: Voltages Supported Max. Continuous Max. # MPX BRMs Supported Phase Configuration Overall Length MPXPRC-V1035XXX 120/208 3 Single-Phase 1035mm, 23U MPXPRC-V1880XXX or & Three-Phase 1880mm, 42U Compatible MPX BRM for given MPX PEM: Module Voltage Branch Max. Continuous Quantity & Receptacle Type Output Phase Configuration Module Length (mm) Branch Monitoring MPXBRM-NBBD6N V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L3-L1 266 Receptacle Management MPXBRM-NRBD6N V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NRBD6N V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L3-L
54 Liebert MPX System Product Selection Guide Table 7 Selections for Power Entry Module MPXPEM-NHBXXX30 MPX PEM Part Number Module Voltage Max. Continuous MPXPEM-NHBXXX V Input Connection IEC PH, 4-Wire Input Phases Module Length (mm) L1-L2-L3-G 266 Compatible MPX PRC for given MPX PEM: Voltages Supported Max. Continuous Max. # MPX BRMs Supported Phase Configuration Overall Length MPXPRC-V1035XXX 120/208 3 Single-Phase 1035mm, 23U MPXPRC-V1880XXX or & Three-Phase 1880mm, 42U Compatible MPX BRM for given MPX PEM: Module Voltage Branch Max. Continuous Quantity & Receptacle Type Output Phase Configuration Module Length (mm) Branch Monitoring MPXBRM-NBBD6N V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L3-L1 266 Receptacle Management MPXBRM-NRBD6N V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NRBD6N V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L3-L
55 Liebert MPX System Product Selection Guide Table 8 Selections for Power Entry Module MPXPEM-NHBXXW30 MPX PEM Part Number Module Voltage Max. Continuous MPXPEM-NHBXXW V Input Connection IEC PH, 5-Wire Input Phases Module Length (mm) L1-L2-L3-N-G 266 Compatible MPX PRC for given MPX PEM: Voltages Supported Max. Continuous Max. # MPX BRMs Supported Input Phases Overall Length MPXPRC-V1035XXX 120/208 3 Single-Phase 1035mm, 23U MPXPRC-V1880XXX or V 6 & Three-Phase 1880mm, 42U Compatible MPX BRM for given MPX PEM: Module Voltage Branch Max. Continuous Quantity & Receptacle Type Output Phase Configuration Module Length (mm) Branch Monitoring MPXBRM-NBBA6A1N 120V 20 (6) NEMA 5-20R L1-N 266 MPXBRM-NBBA6A2N 120V 20 (6) NEMA 5-20R L2-N 266 MPXBRM-NBBA6A3N 120V 20 (6) NEMA 5-20R L3-N 266 MPXBRM-NBBD6N V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NBBD6N V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NBBD6N V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NBBD4O V 20 (4) IEC-C19 L3-L1 266 Receptacle Management MPXBRM-NRBA6A1N 120V 20 (6) NEMA 5-20R L1-N 266 MPXBRM-NRBA6A2N 120V 20 (6) NEMA 5-20R L2-N 266 MPXBRM-NRBA6A3N 120V 20 (6) NEMA 5-20R L3-N 266 MPXBRM-NRBD6N V 20 (6) IEC-C13 L1-L2 266 MPXBRM-NRBD6N V 20 (6) IEC-C13 L2-L3 266 MPXBRM-NRBD6N V 20 (6) IEC-C13 L3-L1 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L1-L2 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L2-L3 266 MPXBRM-NRBD4O V 20 (4) IEC-C19 L3-L
56 6.6 Specifications for Liebert MPX Components Liebert MPX System Product Selection Guide Table 9 Specifications - MPX BRM MPX BRM (Branch Receptacle Module) Single-Phase Liebert MPX System (MPX PEM) Input Selections Phase L1 to Neutral (120VAC) Output Branch Monitoring Support MPXBRM-NBBA6A1N Branch Monitoring, (6) NEMA 5-20R (T-slot) receptacles; Line L1 to Neutral (120VAC) Receptacle Management Support MPXBRM-NRBA6A1N Receptacle Management, (6) NEMA 5-20R (T-slot) receptacles; Line L1 to Neutral (120VAC) Line L1 to L2 (208VAC) Output Branch Monitoring Support MPXBRM-NBBD6N12 Branch Monitoring, (6) IEC-C13 receptacles; Line L1 to L2 ( VAC) MPXBRM-NBBD4O12 Branch Monitoring, (4) IEC-C19 receptacles; Line L1 to L2 ( VAC) Receptacle Management Support MPXBRM-NRBD6N12 Receptacle Management, (6) IEC-C13 receptacles; Line L1 to L2 ( VAC) MPXBRM-NRBD4O12 Receptacle Management, (4) IEC-C19 receptacles; Line L1 to L2 ( VAC) Three-Phase Liebert MPX System (MPX PEM) Input Selections Line L1 to L2 (208VAC) or Phase L1 to Neutral (120VAC) Output Branch Monitoring Support MPXBRM-NBBA6A1N Branch Monitoring, (6) NEMA 5-20R (T-slot) receptacles; Phase L1 to Neutral (120VAC) MPXBRM-NBBD6N12 Branch Monitoring, (6) IEC-C13 receptacles; Line L1 to L2 ( VAC) MPXBRM-NBBD4O12 Branch Monitoring, (4) IEC-C19 receptacles Line L1 to L2 ( VAC) Receptacle Management Support MPXBRM-NRBA6A1N Receptacle Management, (6) NEMA 5-20R (T-slot) receptacles; Phase L1 to Neutral (120VAC) MPXBRM-NRBD6N12 Receptacle Management, (6) IEC-C13 receptacles; Line L1 to L2 ( VAC) MPXBRM-NRBD4O12 Receptacle Management, (4) IEC-C19 receptacles Line L1 to L2 ( VAC) Line L2 to L3 (208VAC) or Phase L2 to Neutral (120VAC) Output Branch Monitoring Support MPXBRM-NBBA6A2N Branch Monitoring, (6) NEMA 5-20R (T-slot) receptacles; Phase L2 to Neutral (120VAC) MPXBRM-NBBD6N23 Branch Monitoring, (6) IEC-C13 receptacles; Line L2 to L3 ( VAC) MPXBRM-NBBD4O23 Branch Monitoring, (4) IEC-C19 receptacles Line L2 to L3 ( VAC) Receptacle Management Support MPXBRM-NRBA6A2N Receptacle Management, (6) NEMA 5-20R (T-slot) receptacles; Phase L2 to Neutral (120VAC) MPXBRM-NRBD6N23 Receptacle Management, (6) IEC-C13 receptacles Line L2 to L3 ( VAC) MPXBRM-NRBD4O23 Receptacle Management, (4) IEC-C19 receptacles Line L2 to L3 ( VAC) Line L3 to L1 (208VAC) or Phase L3 to Neutral (120VAC) Output Branch Monitoring Support MPXBRM-NBBA6A3N Branch Monitoring, (6) NEMA 5-20R (T-slot) receptacles; Phase L3 to Neutral (120VAC) MPXBRM-NBBD6N31 Branch Monitoring, (6) IEC-C13 receptacles; Line L3 to L1 ( VAC) MPXBRM-NBBD4O31 Branch Monitoring, (4) IEC-C19 receptacles Line L3 to L1 ( VAC) Receptacle Management Support MPXBRM-NRBA6A3N Receptacle Management, (6) NEMA 5-20R (T-slot) receptacles; Phase L3 to Neutral (120VAC) MPXBRM-NRBD6N31 Receptacle Management, (6) IEC-C13 receptacles Line L3 to L1 ( VAC) MPXBRM-NRBD4O31 Receptacle Management, (4) IEC-C19 receptacles Line L3 to L1 ( VAC) 52
57 Liebert MPX System Product Selection Guide 6.7 Dimensional Drawings - Adaptive Rack PDUs Figure 30 Liebert MPX MPXPRC-1035mm mixed modules MPX-PRC cover/spacer 2.9" (75mm) 4.1" (104mm) 2.9" (75mm) 10.5" (266mm) MPX-BRM circuit breaker protection body MPX-PRC (Power Rail Chassis) 10.5" (266mm) 40.6" (1035mm) TOP VIEW MPX-BRM (Branch Receptacle Modules) SIDE VIEW 10.5" (266mm) 8.7" (220mm) MPX-PEM (Power Entry Module) Input power cord (variable) 4.1" (104mm) NOTES: 1. Dimensional view of 1035mm MPX-PRC application. 2. Representative module mix may not reflect user selection. 3. Operating temperature: 41 F to 131 F (5 C to 55 C) 4. Storage temperature: -13 F to 185 F (-25 C to 85 C ) MPX-MIXMOD1035 Rev. 0 53
58 Liebert MPX System Product Selection Guide Figure 31 Liebert MPX MPXPRC-1880mm mixed modules MPX-PRC cover/spacer 2.9" (75mm) 4.1" (104mm) 2.9" (75mm) END VIEW 10.5" (266mm) 10.5" (266mm) 4.1" (104mm) MPX-PRC (Power Rail Chassis) 10.5" (266mm) 10.5" (266mm) 74" (1880mm) TOP VIEW MPX-BRM (Branch Receptacle Modules) SIDE VIEW 10.5" (266mm) 10.5" (266mm) 10.5" (266mm) MPX-PEM (Power Entry Module) MPX-BRM circuit breaker protection body Input power cord (fixed) 4.1" (104mm) NOTES: 1. Dimensional view of 1880mm MPX-PRC application. 2. Representative module mix may not reflect user selection. 3. Operating temperature: 41 F to 131 F (5 C to 55 C) 4. Storage temperature: -13 F to 185 F (-25 C to 85 C ) MPX-MIXMOD1880 Rev. 1 54
59
60 Ensuring The High Availability Of Mission-Critical Data And Applications. Emerson Network Power, the global leader in enabling business-critical continuity, ensures network resiliency and adaptability through a family of technologies including Liebert power and cooling technologies that protect and support business-critical systems. Liebert solutions employ an adaptive architecture that responds to changes in criticality, density and capacity. Enterprises benefit from greater IT system availability, operational flexibility and reduced capital equipment and operating costs. While every precaution has been taken to ensure the accuracy and completeness of this literature, Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. Liebert is a registered trademark of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. SL-20828_REV1_02-11 Technical Support / Service Web Site Monitoring [email protected] Outside North America: Single-Phase UPS & Server Cabinets [email protected] Outside North America: Three-Phase UPS & Power Systems Outside North America: Environmental Systems Outside the United States: Locations United States 1050 Dearborn Drive P.O. Box Columbus, OH Europe Via Leonardo Da Vinci 8 Zona Industriale Tognana Piove Di Sacco (PD) Italy Fax: Asia 29/F, The Orient Square Building F. Ortigas Jr. Road, Ortigas Center Pasig City 05 Philippines Fax: Emerson Network Power. The global leader in enabling Business-Critical Continuity AC Power Connectivity DC Power Embedded Computing Embedded Power Infrastructure Management & Monitoring Outside Plant Power Switching & Controls Precision Cooling EmersonNetworkPower.com Racks & Integrated Cabinets Services Surge Protection Emerson, Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks of Emerson Electric Co. or one of its affiliated companies Emerson Electric Co.
Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity
Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment AC Power For Business-Critical Continuity Enhanced Performance And Management Of Dynamic IT Spaces IT space is
AC Power For Business-Critical Continuity. Liebert MPH. User Manual North American & European Applications
AC Power For Business-Critical Continuity Liebert MPH User Manual North American & European Applications TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS................................................1
Rack Power Distribution Unit For Critical IT Equipment
AC Power for Business-Critical Continuity Rack Power Distribution Unit For Critical IT Equipment One Move Ahead With Emerson Network Power Emerson Network Power, a division of Emerson, is a global company
QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview
Overview Fixed Cord PDUs and Extension Bars have a unique architecture designed specifically for 1U fixed rail servers (HP ProLiant DL360, HP ProLiant DL320, HP ProLiant DL140). This new design consists
ZONIT POWER DISTRIBUTION SYSTEM ORDER CATALOG
ZONIT POWER DISTRIBUTION SYSTEM ORDER CATALOG Introduction The Zonit Data Center Power Distribution System (zpds ) offers an ultrareliable, turnkey power distribution system for modern high-availability
DCF Optimized Rack System Selection Guide
DCF Optimized Rack System Selection Guide DCF Optimized Rack System: Optimized Design, Optimized Delivery, Optimized Value A Rack System Designed to Meet The Challenges Your Data Center Faces Today Your
Rack Power Distribution For Critical IT Equipment More efficient Simpler Better
Rack Power Distribution For Critical IT Equipment More efficient Simpler Better Enhanced Performance and Management of Dynamic IT Spaces Enhance Business Agility, Efficiency and Availability with Emerson
QuickSpecs. HP Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview
Overview HP Modular PDUs have a unique modular architecture designed specifically for data center customers who want to maximize power distribution and space efficiencies in the rack. Modular PDUs consist
Rack Power Distribution
The Rack PDU Selector is located at: www.apc.com/tools/selector/pdu Test drive a metered or switched Rack Power Distribution Rack PDU at testdrive.apc.com 132 Fairgrounds Road West Kingston, RI 02892 Phone:
Distributing Power to Blade Servers
Distributing Power to Blade Servers Ten steps to selecting the optimal power distribution design With the growth in blade servers with dual or triple power supplies, a single rack of equipment can easily
Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions
Self-Retracts 30 ft. Charge Cable Length Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions Safe, Convenient & Clean EV Charging The EVoReel cable management solutions
Rack Power Distribution. Worldwide
Rack Distribution Worldwide Introduction APC TM by Schneider Electric TM offers a wide array of standardized Rack Distribution Units (PDUs) designed to increase manageability and efficiency in your data
QuickSpecs. HP 480/277 Volt Solutions. Overview
Overview As the quest for efficiency continues it becomes apparent that what worked in the past needs improvement. More and more data center managers are looking at alternate power plans to distribute
QuickSpecs. HP Managed Power Distribution Units (mapdu) Overview
Overview Looking for a power distribution unit that meets the demands of high temperature operating environments and provides monitoring and switching capabilities? The HP Managed Power Distribution Unit
Rack Systems Solutions
Rack Systems Solutions Designed to simplify cable management and improve power distribution Engineered by APC by Schneider Electric for Dell, NetShelter S is the next-generation rack enclosure solution
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers
Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers An intelligent physical infrastructure is required
How To Power A Bladecenter H Servers
Solutions Guide for IBM Data Center Architecture: IBM BladeCenter H Servers In today s high-demand enterprise environment, organizations need a reliable infrastructure to run compute-intensive applications
SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial
SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMX1000RT2U Highlights 1kVA / 1000VA / 900W line-interactive 2U rack/tower UPS, Sine
Power Commander Power Distribution Units from Wiremold/Legrand offer
Power Commander Power Distribution Units Rack Power Distribution Solutions for IT/Network Environments Power Commander Power Distribution Units from Wiremold/Legrand offer comprehensive power distribution
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial
SmartOnline 200-240V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SU5000RT4UHV Description Tripp Lite SU5000RT4UHV 5000VA / 5kVA /
Model #: SMART2200CRMXL
Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: [email protected] Model #: SMART2200CRMXL SmartPro Compact Rackmount UPS System - Precision Protection for
PE8216/PE8324. Energy Intelligence Solutions
PE8216/PE8324 As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center power usage. The
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial
SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial MODEL NUMBER: SMART2200RM2U Highlights 2.2kVA / 2200VA / 1920W line interactive 2U
8 Intelligent PDUs. Intelligent Power Distribution Units for Data Centers
BRC_PDU_US_B_BRC_IcePack 4/30/13 11:31 AM Page 2 8 Intelligent PDUs Intelligent Power Distribution Units for Data Centers Intelligent Power Distribution Units Siemon s line of intelligent PDUs provide
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments
Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments Model #: SM2000RMX Heavy-duty, industrial-grade metal housings Shock and vibration rated to MIL-STD-810D 19 inch
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications
SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications Model #: SU3000RTXL3U 3000VA online 3U rack / tower UPS Enhanced serial communications
QuickSpecs. HP Remote Monitored Power Distribution Units (mpdu) Overview
Overview HP Remote Monitored Power Distribution Units (PDU) provide rack level power monitoring over the network. With billing grade accuracy these PDUs are excellent choices for data centers wanting to
Panduit Infrastructure Management Software for Data Centers and Enterprises
Panduit Infrastructure Management Software for Data Centers and Enterprises SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Features: Simple
Remote Site Management Solutions
Remote Site Management Solutions Bay Technical Associates 200 N. 2 nd Street Bay St. Louis, MS 39520 800-523-2702 * Fax 228-467-4551 International 228-467-8231 1.0 REMOTE SITE MANAGEMENT (SELLING THE CONCEPT
PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets
PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets MODEL NUMBER: BC600SINE Highlights 600VA tower 120V standby UPS with SINE WAVE output Maintains AC output during power
R5000 Uninterruptible Power System (UPS) Overview
Overview The innovative Minimally Switched Technology used in the HP R5000 UPS improves the performance over traditional line-interactive UPS designs while reducing the cost, weight, and size of traditional
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out
APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out APC Matrix-UPS, 3750 Watts / 5000 VA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, SmartSlot, Extended runtime model Includes: CD with software,
R5000 Uninterruptible Power System (UPS) Overview
Overview The innovative Minimally Switched Technology used in the HP R5000 UPS improves the performance over traditional lineinteractive UPS designs while reducing the cost, weight, and size of traditional
Adaptive power distribution in the data center
AC power supply for Business-Critical Continuity Adaptive power distribution in the data center A step towards the future with Emerson Network Power Contents Server rack power distribution Rack PDUs overview...
Uninterruptible Power Supply
96-01101 / rev. 2e / 2-2-12 Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs of A/V systems Features
Precisely distribute, monitor, analyze and manage power distribution in your facility to maximize processing capacity and promote power efficiency.
SECTION FOUR Table of Contents Page 69-78 Enclosure Power Distribution Units (PDUs) 70 71 Single-Phase Basic/Smart PDUs 72 3-Phase Basic/Smart PDUs 73 Single- and 3-Phase Switched PDUs 74 PDU Accessories
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire
SmartOnline 200-240V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire MODEL NUMBER: SU6000RT3UHV Highlights 6000VA / 6kVA / 4200W on-line double-conversion
ED1259R5 Updated April 2011 For latest specs visit www.legrand.us/wiremold
Rack Power Distribution Solutions for IT/Network Environments Wiremold Power Commander Power Distribution Units offer comprehensive power distribution solutions for IT environments from networking solutions
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SMART1000RM1U Description Tripp Lite SMART1000RM1U 1000VA / 1kVA / 800 watt line interactive,
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS, Sine
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial
SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial MODEL NUMBER: SMART750RM1U Highlights.75kVA / 750VA / 600W line interactive 1U rackmount UPS,
Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V
SmartPro VS Tower UPS System Intelligent, line-interactive power management system Model #: SMART2200VS 2200VA / 2.2kVA line interactive tower UPS Maintains 120V nominal output over an input range of 79
How To Upgrade An Hp Power Distribution Rack To A Power Distribution Unit
Overview Power protection in the data center is critical to maintain up time, and the increased densities in data centers is driving the need for uninterruptible power with increased power density, power
Cisco Nexus 7000 Series Power Supply Modules
Cisco Nexus 7000 Series Power Supply Modules Product Overview The Cisco Nexus 7000 Series Power Supply Modules (Figures 1 and 2) deliver fault tolerance, high efficiency, load sharing, and hot-swappable
TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial
TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial MODEL NUMBER: SM1000RM1UTAA Description Tripp Lite SM1000RM1UTAA 1000VA / 1kVA / 800 watt line
OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port
OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port MODEL NUMBER: OMNIVS1500 Highlights 1500VA / 1.5kVA tower 120V line-interactive UPS Corrects brownouts and overvoltages from 75 to 147V
Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation
One Dell Way Round Rock, Texas 78682 www.dell.com Dell Enterprise White Paper Power Distribution Systems for the Dell PowerEdge M1000e Modular Server Enclosure - Selection and Installation January, 2008
HP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
PE6108/PE6208/PE8108/PE8208
Energy Intelligence Solutions PE6108/PE6208/PE8108/PE8208 eco PDU Distribution Unit ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency
LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA. General Specification
08/17/12 Rev2 LTR Series General Specification 700 VA to 2.1 KVA 1.0 General LTR Series Uninterruptible Power Systems 700 VA - 2.1 KVA General Specification This specification describes the features and
APC Step-Down Transformer. User s Manual
APC Step-Down Transformer Models: AP9621, SURT005, SURT006, SUTF3, SYTF2, SYTF2J, SYTF3 and SYTF3J User s Manual English 990-7820D, July 2003 TABLE OF CONTENTS APC Contact Numbers and Support Visit the
QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA - 12859 North America Version 5 August 22, 2008 Page 1
Overview It's getting harder to manage a data center efficiently, with rising utility bills and ever-increasing demands due to processor power and server density increases. Growing user requests mean heavier
MAJORSINE Power Inverter
MAJORSINE Power Inverter Product Features: 24, 48, 130 V 1 KVA/800 Watts Output 2 KVA/1600 Watts Output 100-120 VAC Range 208-240 VAC Range Standard 19 /23, Pure Sine Wave Output High Low EMI/RFI Emissions
Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA
Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA Liebert GXT3 is a full feature UPS providing reliable protection for IT network equipment and data centers. It is a true
IEC 309 INTERLOCKS NORTH AMERICAN
IEC 309 INTERLOCKS NORTH AMERICAN SWITCH VERSION with MCB (Circuit Breakers) 20, 30, 60 Amp NEMA 4X Watertight (IP67) Drawing A (See Drawing on Specification Page) 20, 30, 60 Amp Spashproof (IP44) Drawing
Product Snapshot. Powerware 9140 Uninterruptible Power System. Superior de-centralized power protection for medium- and high-density rack environments
Powerware 9140 Uninterruptible Power System Product Focus Superior de-centralized power protection for medium- and high-density rack environments Product Snapshot Power Rating: Nominal Input Voltage: Nominal
EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility
EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001 2014 Class 2800 CONTENTS Description............................................ Page 2 Outdoor
SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:
SWITCH The Budderfly lighting switch is a Decora style, plug-and-play replacement for your existing building switches. Installing a Budderfly adapter transforms your building s existing wiring into the
Internet Office 750VA Ultra-compact Standby 120V UPS with USB port
Internet Office 750VA Ultra-compact Standby 120V UPS with USB port MODEL NUMBER: INTERNET750U Highlights 750VA ultra-compact 120V standby UPS Maintains AC output during power failures 6 UPS battery supported
Increasing Data Center Efficiency by Using Improved High Density Power Distribution
Increasing Data Center Efficiency by Using Improved High Density Power Distribution By Neil Rasmussen White Paper #128 Executive Summary A new approach to power distribution for high density server installations
3U, 2200 VA Audio/Video Pure Sine Wave UPS System
3U, 2200 VA Audio/Video Pure Sine Wave UPS System MODEL NUMBER: HTR22-3U Description Tripp Lite's HTR22-3U Pure Sine Wave 2200VA/1600W on-line, double-conversion UPS system prevents media data loss, equipment
EKOS Cart. Instructions for Use
EKOS Cart Instructions for Use EKOS Corporation 11911 North Creek Parkway South Bothell, WA 98011 USA (425) 415-3100 (tel) (425) 415-3102 (fax) [email protected] (e-mail) - 1-4913-002 REV E Intended Use
Table of Contents. 1. Introduction...1. 2. PDU Package...2. 3. Function...3. 4. Installation...5. 5. Web Interface...7
PDU User Manual Table of Contents 1. Introduction...1 2. PDU Package...2 3. Function...3 4. Installation...5 5. Web Interface...7 1. Introduction The PDU is an Internet ready device designed and is equipped
QuickSpecs. HP R/T3000 G2 Uninterruptible Power System (UPS) Overview
Overview The industry leading packs up to 3000 watts into a space saving 2U design. Proven Digital Signal Processor (DSP) double conversion system provides clean, reliable power protection in an energy
CS-24HEK4B3H2 (Master) CL-24HEK4B3H2 (Expansion) Key Features. Inputs
CS-24HEK4B3H2 (Master) CL-24HEK4B3H2 (Expansion) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis
Power Distribution Considerations for Data Center Racks
Power Distribution Considerations for Data Center Racks Power Distribution Considerations for Data Center Racks Table of Contents 3 Overview 4 At what voltage do you run all the IT equipment? 4 What electrical
HP R/T3000 G2 Uninterruptible Power System (UPS) Overview
Overview The industry leading packs up to 3000 watts into a space saving 2U design. Proven Digital Signal Processor (DSP) double conversion system provides clean, reliable power protection in an energy
Eaton epdu Data Center Product Catalog
Power distribution solutions Eaton epdu Data Center Product Catalog Switch N to Eaton. 2 eaton corporation Enclosure Power Distribution Units Table of contents Product Line Overview... 4 Choosing epdu
High-Efficiency AC Power Distribution for Data Centers
High-Efficiency AC Power Distribution for Data Centers White Paper 128 Revision 2 by Neil Rasmussen > Executive summary The use of 240 volt power distribution for data centers saves floor space, simplifies
Eaton epdu. Intelligent and flexible power distribution
Eaton epdu Intelligent and flexible power distribution Introduction and overview With today s changing technology, increasing power demands and the need for reliability, data centre professionals require
HP R12000 and R18000 DirectFlow UPS User Guide
HP R12000 and R18000 DirectFlow UPS User Guide Abstract This document includes installation, configuration, and operation information for the HP R12000 and R18000 DirectFlow UPS. This document is for the
Amplifier: AMP-8125. Feature Summary
Savant Systems AMP-825 is a multi-room amplifier for distributed audio applications. The AMP-825 is an ultraefficient Class D amplifier delivering 8 channels of reliable amplification rated at 25 watts
SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial
SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial MODEL NUMBER: SMART1500SLT Highlights 1.5kVA / 1500VA line interactive tower UPS; Sine wave output
Internet Office 500VA Tower Standby 120V UPS with USB port
Internet Office 500VA Tower Standby 120V UPS with USB port MODEL NUMBER: INTERNETOFFICE500 Highlights 500VA tower 120V standby UPS Maintains AC output during power failures 3 UPS battery supported outlets,
Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P
Technical Data Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P Topic Page 1609-P Specifications 2 1609-P Approximate Dimensions and Shipping Weights 3 Additional Resources
SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial
SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial MODEL NUMBER: SMART500RT1U Description Tripp Lite's SMART500RT1U intelligent, line-interactive rack/tower uninterruptible
Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility
Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility Catalog 2800CT1001R02/13 2013 Class 2800 CONTENTS Description............................................ Page 2 Indoor Charging
Chassis, Power Supply, and Element Management
Chassis, Power Supply, and Element Management C-COR CHP Max5000 Converged Headend Platform Accelerate deployment of new, revenue generating advanced services Innovative technology creating converged high-
Power Supplies 3. SDN-P DIN Rail Series
SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility in demanding applications.
BC Pro UPS System Standby UPS System
BC Pro UPS System Standby UPS System Model #: BCPRO1400 1400VA standby, tower UPS system Offers battery derived AC output during blackouts and brownouts starting at 99V 6 protected AC outlets (NEMA 5-15R)
DVI DA2 and DVI DA 4 User Guide
DVI DA2 and DVI DA 4 User Guide This guide describes the installation and operation of the Extron DVI DA2 and DVI DA4 Distribution Amplifiers. Unless stated otherwise, distribution amplifier or the unit
Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system
Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system Model #: SMART500RT1U 500VA line interactive 1U rack/tower UPS 7 outlets with 1 switchable load bank Simultaneous
TrueAlarm Fire Alarm Systems
TrueAlarm Fire Alarm Systems UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Fire Alarm System Accessories, 4190 Series PC Annunciator with Multi-Client Capability Features Fire alarm control
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY
PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY 7320 Ashcroft, Suite 104 Houston, Texas 77081 p: 713-772-1404 f: 713-772-7360 e: [email protected] www.juicegoose.com 06-06 CONGRATULATIONS
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass
AIS 3000 APC AIS 3000 15kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass APC AIS 3000, 12 kw / 15 kva,input 208V 3PH / Output 120V, 208V, 208V 3PH, Interface Port DB-9 RS-232,
How To Power A Power Supply Shelf With A Power Unit (Hp 2920)
Overview Models HP 640 Redundant/External Power Supply Shelf J9805A Key features Provides redundant or extenal power for HP 2920 Switch Series products Uses same modular power supplies as the HP 2920 Switches
Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions
Self-Retracts 30ft Cable Length Electric Vehicle Charging Station Products EVoReel Safe, Convenient & Clean EV Charging EVoReel products are engineered to provide improved safety and convenience for electric
Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System
Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System MODEL NUMBER: HTR05-1U Description Tripp Lite's HTR05-1U AVR Series intelligent, Automatic Voltage Regulated
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
REGULINE 600VA / 1000VA REGULATOR USER MANUAL
REGULINE 600VA / 1000VA REGULATOR USER MANUAL TUNÇMATİK REGULINE SERIES AUTOMATIC VOLTAGE REGULATOR Models: REGULINE 600VA / REGULINE 1000VA Principle of Operation Automatic Voltage Regulators regulate
3500/93 System Display
3500/93 System Display Bently Nevada* Asset Condition Monitoring Description The 3500/93 System Display is designed to meet the requirements of American Petroleum Institute (API) Standard 670 and provide
APC. DIN Rail Control Panel Mounting Uninterruptible Power Supply. Catalog
APC DIN Rail Control Panel Mounting Uninterruptible Power Supply Catalog 2014 Contents Introduction, description... 4 Specifications...5 References....6 Dimensions...7 Wiring diagrams....8 Product reference
EVlink Electric Car Charging Stations Powering the Future of Sustainable Mobility
EVlink Electric Car Charging Stations Powering the Future of Sustainable Mobility Catalog 2800CT1001 R09/15 2015 Class 2800 CONTENTS Description............................................ Page 2 Home
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial
SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial MODEL NUMBER: SMARTINT3000VS Highlights 3kVA / 3000VA / 2250W line interactive tower UPS system 230V
APC 3Phase Power Distribution
APC 3Phase Power Distribution North American 3 Phase Business Development Team All content in this presentation is protected 2008 American Power Conversion Corporation Objectives Understand the entire
The Different Types of AC Power Connectors in North America
The Different Types of AC Power Connectors in North America White Paper 20 Revision 1 by James Spitaels > Executive summary A confusing array of AC power plugs and receptacles exist to deliver power to
LIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.
Appro HyperBlade A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing. Appro HyperBlade clusters are flexible, modular scalable offering a high-density
10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable
10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable StarTech ID: IES101002SFP The IES101002SFP 10-port Ethernet switch delivers flexibility and control of your network by