Series 8900 Product Series 8900 Gas Chromatograph Multipurpose Gas Chromatograph Monitor single or multiple gas components Applications Well logging - Fast C1-C5 Area monitoring of toxic gases for industrial hygiene and safety - Ethylene Oxide, Acrylonitrile, Butadiene, Styrene, Epichlorohydrin and many others Fenceline (perimeter) monitoring around industrial and remediation sites - BTEX and other VOC's Scrubber efficiency - Hydrocarbons and VOC's Carbon bed breakthrough detection - Solvents and organic compounds Quality Assurance Monitoring, contaminant analysis or blending of industrial gases Methane/Non-methane analysis A list of over 200 detectable gases is available upon request Features & Benefits Accurate & specific to a wide variety and range of gases Continuous unattended operation Operates with or without a computer Automatic calibration and baseline correction for long term stability Outputs include digital, user definable analog and user definable logic PC based SkyChrom software stores multiple analytical methods and chromatograms Multipoint sampling options Onboard short-term data storage Online gas analysis over a broad range of concentrations The Baseline Series 8900 GC is microprocessor based and contains powerful embedded firmware. There are a variety of state of the art detector, calibration and gas train options offering the flexibility and precision necessary to analyze from sub-parts per billion (sub-ppb) to percent levels. The 8900's automatic calibration is ideal for unattended operation. It can be set up on a bench-top or rack-mounted, and its compact size makes it transportable. There are a variety of industry standard outputs, such as network (LAN), RS232, multiple 4-20 ma or 0-20 ma, and multiple relays for concentration alarms, diagnostics or user specified timed events. Gas chromatography applications are factory pre-configured to enable easy start up and operation. The computer can be disconnected and the analyzer will operate independently. When connected to SkyChrom, data can be collected in a universal text format with a user definable data export utility for custom reports. Chromatograms can be stored continuously or based on events such as alarms. Detector options include Photoionization Detector (PID), Flame Ionization Detector (FID) and Thermal Conductivity Detector (TCD).
Specifications Detectors Relay Outputs Analog Outputs Digital Outputs Optional Outputs Inputs Display Software Columns Valves Detector Sampling Samplers Calibration Power Photoionization (PID) 10.6 ev or 11.7 ev High-sensitivity (PID) <50ppt Benzene Flame Ionization (FID) Thermal Conductivity (TCD) Consult Baseline for other options Series 8900 Gas Chromatograph Standard - 5 programmable (latched/not, NE/ NNE, NO/NC) as contact closure (1A @ 30Vdc) Standard - 1 0-20mA or 4-20mA isolated Standard - RS-232, LAN Analog output board - up to 20 additional programmable 4-20 ma outputs Voltage outputs - 0-1 V, 0-5 V or 0-10 V (others on request) Relay board - up to 32 additional programmable relays Optional digital input board for 3 contact closure inputs. Supports start analysis, start calibration, and analyze calibration gas as sample Digital vacuum fluorescent, 20 characters x 2 lines SkyChrom external integration, GC setup and data acquisition software for PC Packed or Capillary / application specific Standard: (1) 10-Port valve (additional valves optional) Single or dual detector Single point analyzer for pre-filtered ( 0.1 microns), non-condensing samples Internal 4, 8, 16 point sampling options (not available on an FID) Built-in or external sample pump Injection port (on sample loop) 8950 Multipoint Sampler (4/8/16 pt) w/ up to 16 analog outputs & 32 relays Automatic or Manual using a dedicated standard 90-260 VAC, 50/60Hz Physical Characteristics Dimensions 3u, 17.41"(44.2cm) W x 9.36"(23.8 cm) D x 14.83"(37.7cm) H Weight 30 lb (13.64 kg) Configuration Bench-top or rack-mount 19"(48.3cm) panel Operating Temperature 32-104 F (0-40 C) Connections 1/4"(6.35mm) tube fitting connectors or consult Baseline Operating Humidity 0-95% (non-condensing) MOCON and Baseline are registered trademarks of MOCON, Inc.. Other trademarks are those of their respective holders. Brochure: D010.2 P.O. Box 649, 19661 Highway 36 Lyons, CO 80540 P: 1.800.321.4665 1.303.823.6661 F: 303.823.5151 E: info@baselineindustries.com www.baselineinc.com
NonMethane Hydrocarbon Analyzer Product Series 9000NMHC Analyzer Accurate and Reliable Methane / Non-Methane Hydrocarbon Analysis over a Broad Range of Concentrations Continuous Monitoring of Methane and Non-Methane Hydrocarbons in Non-Condensing Gases Applications Ambient Air Monitoring Networks Clean Rooms Air & Oxygen Purity in Air Separation Plants Features & Benefits Hydrocarbon Detection from sub-ppm to 1000 ppm (Methane) Flame Ionization Detector Graphical Display with Easy to use Menu System Sleek Rack Mountable Profile Internal, Multipoint Sampling Option Automatic Calibration at User-Defined Intervals FlowGuard Electronic Control of Fuel, Air and Sample Electronic Back-Pressure Regulator with Sample Bypass System Discrete, multilevel concentration & fault alarms Programmable Analog Output Ranges Programmable Relays for Concentration, Alarms, Events and Diagnostics Automatic FID (Flame Ionization Detector) Ignition Automatic Shut-off of Sample, Fuel and Combustion Air Remote Operation via RS-232 and Ethernet Optional: 9000 Keeper Software allows for Remote Monitoring and Control Continuous and Fully Automated Gas Analysis As part of the Baseline Series 9000 Hydrocarbon Analyzer family, the 9000 NMHC is designed to measure the total hydrocarbons, methane and non-methane hydrocarbon content in gas samples. Output options include analog, digital and logic capabilities. The detector used is a FID (Flame Ionization Detector) and an oxidation catalyst that is switched in and out of a portion of the sample stream. The catalyst oxidizes all hydrocarbons except methane, for a methane measurement. The methane value is then automatically subtracted from the total hydrocarbon concentration to determine the non-methane hydrocarbon reading. The Series 9000 NMHC can be configured with internal components for single or multipoint analysis of non-condensing gas samples. The automatic calibration feature enhances the long-term analytical stability of the instrument. These features place the instrument well ahead of the competition in performance, automation and configurability.
Specifications Detector Oxidizer Ranges Repeatability Drift Response Time Alarms Sampling Calibration Support Gas Power Relay Outputs Analog Outputs Digital Outputs Series 9000NMHC NonMethane Hydrocarbon Analyzer (FID) Flame Ionization Detector Oxidizes NonMethane Hydrocarbons User definable based upon calibration within; MDQ 0.06 ppm, Full-scale 1-200 ppm (Air Balance) MDQ 0.1 ppm, Full-scale 1-1,000 ppm (Air Balance) MDQ 0.03 ppm, Full-scale 1-200 ppm (O Balance) +/- 1% Full-scale response +/- 1% of full-scale over 24 hours < 30 seconds to 90% of final reading Multilevel concentration and fault alarms that result in audible and visual alarms Alarms may also be mapped to relays to control external equipment Internal single module for pre-filtered (<0.1 microns) non-condensing samples, with or without sample pump Programmable automatic or manual calibration Hydrogen 35 cc/min (H 2 He Blend 100 cc/min) Air 175 cc/min (typical) Hydrocarbon content must be less than 1 ppm Fuel blend options available, consult Baseline 90-230 VAC, 50/60Hz, 3A 5 programmable form A relays rated to 3A @ 230V AC (optional additional 9 relay output board) 1 programmable 0-20mA or 4-20mA isolated output (optional additional 3 analog output board) RS-232, Ethernet FrontView SideView Mensions are Displayedin inches BackView Phsical Characteristics Dimensions 3u, 19.00"(48.3cm) W x 14.25"(36.2cm) D x 5.25"(13.3cm) H Weight < 20 lb Configuration Bench-top or rack-mount 19"(48.3cm) panel Operating Temperature 32-104 F (0 Connections 1/4"(6.35mm) tube fitting connectors Operating Humidity 0-95% (non-
Total Carbon Analyzer Product Series 9000TCA Analyzer Accurate and Reliable Analysis of Total Hydrocarbons and Total Carbons Fully Automated Analysis over a Broad Range of Concentrations Applications Hydrocarbon and CO / CO 2 impurities in ultra pure inert gases with no oxygen content - Argon - Helium - Hydrogen - Nitrogen Continuous and Fully Automated Gas Analysis Features & Benefits Flame Ionization Detector Graphical Display with Easy to use Menu System Sleek Rack Mountable Profile Automatic Calibration at User-Defined Intervals FlowGuard Electronic Control of Fuel, Air and Sample Electronic Back-Pressure Regulator with Sample Bypass System Discrete, multilevel concentration & fault alarms Programmable Analog Output Ranges Programmable Relays for Concentration, Alarms, Events and Diagnostics Automatic FID (Flame Ionization Detector) Ignition Automatic Shut-off of Sample, Fuel and Combustion Air Remote Operation via RS-232 and Ethernet Optional: 9000 Keeper Software allows for Remote Monitoring and Control As part of the Baseline Series 9000 Hydrocarbon Analyzer family, the 9000TCA has a dynamic range from 0.1 ppm to 100 ppm and is designed to measure total hydrocarbon content and provide a combined carbon monoxide (CO) and carbon dioxide (CO 2 ) reading. The analyzer has a generous complement of analog, digital and logic output capabilities. The detector used is a FID (Flame Ionization Detector) along with a reduction catalyst that is switched in and out of the sample stream. Total hydrocarbons are first measured and the catalyst converts the CO & CO2 to methane and leaves the hydrocarbons unchanged for a total carbon measurement. The total hydrocarbon value is then automatically subtracted from the total carbon concentration to determine the combined CO /CO2 reading. The Series 9000TCA can be configured for single or multi point analysis. The automatic calibration feature enhances the long-term analytical stability of the instrument. These features place the instrument well ahead of the competition in performance, automation and configurability.
Specifications Series 9000TCA - Total Carbon Analyzer Detector (FI ID) Flame Ionization Detector Methanizer Converts low levels of CO and CO 2 to methane Ranges User definable based upon calibration within 0-100 ppm MDQ 0.1 ppm Repeatability +/- 1% Full-scale response Drift +/- 1% of full-scale over 24 hours Response Time T90 < 30 seconds Alarms Mu ultilevel concentration and fault alarms that result in audible and visual alarms s. Alarms may also be mapped to relays to control external equipment Sampling Internal single or multi-point modules for pre-filtered (<0.1 microns), non-condensinthout samples, with or sample pump wit Calibration Pro rogrammable automatic or manual calibration Support Gas Hy ydrogen 40cc/min, Air 200 cc/min (typical). Hydrocarbon content must be less s than 1 ppm. Fuel blend options ava vailable, consult Baseline Power 90-230 VAC, 50/60Hz, 3A Relay Outputs 5 programmable form A relays rated to 3A @ 230V AC (optional additional 9 rela ay output board) Analog Outputs 1 programmable 0-20mA or 4-20mA isolated output (optional additional 3 ana alog output board) Digital Outputs RS-232, Ethernet FrontView SideView Dimensions are displaye yed in inches BackView Physical Characteristics Dimensi 3u, 19.00"(48.3cm) W x 14.25"(36.2cm) D x 5.25"( "(13.3cm) H Weight < 20 lb (9.07kg) Configura Bench-top or rack-mount 19"(48.3cm) panel Operating Temperature 32-104 F (0-40 C) Connecti 1/4"(6.35mm) tube fitting connectors Operating Humidity 0-95% (non-condensing g)