Series 8900 Gas Chromatograph

Similar documents
On-line Dissolved Gas Analysis

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Transformer Oil Gas Analysis

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

PortaSens ll G AS DETECTOR

Process Instrumentation

Application Requirement

CHROMOCTANE O N LINE ANALYZER

BTU ANALYSIS USING A GAS CHROMATOGRAPH

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

PowerGem Pro Uninterruptible Power Supply

Portable Gas Analyzer with Wireless Transmission of Gas Concentrations and GPS Coordinates

The photoionization detector (PID) utilizes ultraviolet

Agilent 7697A Headspace Sampler Data Sheet

Residual Gas Analyzers

TRL-onlineTOC Monitor is designed for monitoring carbon content in

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

QGA Quantitative Gas Analyser

Gas sensors for greenhouse measurements

Process gas chromatographs. Measurement made easy. Compliance Solutions for 40CFR60 Subpart Ja

SYNSPEC GC s ALPHA 115 and ALPHA 116

MATHESON REFINERY PROGRAM for Specialty Gas Supply. Experience the MATHESON Commitment to Supply Chain Excellence

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

ALTAIR 5X Multigas Detector Bid Specification

T a b l e o f C o n t e n t s

Thermal Conductivity Detector

High Power Programmable DC Power Supplies PVS Series

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)

Laboratory Gas Generators. LABGAS Pure & Simple

Temperature & Humidity SMS Alert Controller

Multi-Range Programmable DC Power Supplies 9115 Series

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Ultima X Series Gas Monitors

23 The Thermal Conductivity Detector

How To Use An Irius Pid Detector

Chromatograph Maintenance and Troubleshooting Class # 5050

API Marine. BMS Presentation. Ballast Measurement Systems

The Ambient Air Monitoring System

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

CRYOCOOLER CONTAMINATION STUDY. S.W.K. Yuan, D.T.Kuo, and A.S. Loc. BEI Technologies, Cryocooler Group Sylmar, CA ABSTRACT

MATHESON STACK EMISSION CALIBRATION PROGRAM. Experience the MATHESON Commitment to Supply Chain Excellence

Analytical Instruments Smart Analyzer 90 Type SMA

Elemental analyzer multi EA 5000

Q U A D S C A N I I GENERAL User Interface Enclosure Display QUADSCAN II Temperature Range RECEIVER DISPLAY Sensor Weight Optional Relay Enclosure

Get the Right GC for Your Industry

ABSTRACT INTRODUCTION

Natural Gas Processing Solutions Using the 700XA Gas Chromatograph

Clarus 580 Gas Chromatograph

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

1.44 kw Programmable DC Power Supplies XLN Series

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Buckeye Detection Systems Fixed Detection Systems Application Survey

Technical Specification. Generating Set with Waukesha engine burning natural gas

Loop-V4300 MINI DACS E1/ T1 CONVERTER

Hydrogen as an alternative to Helium for gas chromatography.

TABLE OF CONTENT

IFC. A new perspective i l ifi ti. p p g p. Single softw FractPAL software plug-in for Agilent ChemStation. Medicinal Chemistry.

Analytical Service Certification Program

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

NEW. EVEN MORE data acquisition and test stand automation

Uninterruptible Power Supply

DM70 Hand-Held Dewpoint Meter for Spot-Checking Applications

Fundamentals of Gas Chromatography

Rackmount Intelligent Pressure Scanners

NetScanner System. Toronto: , Montreal: , Toll Free: ,

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

Rosemount Analytical 1500XA Process Gas Chromatograph

AUTOMATIC CHANGEOVER MANIFOLD Series 915

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Everything you need for protection scheme testing

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

SMS GSM Alarm Messenger

Phase Modular Finally the benefits of Modular ups are for all

The Universal DAQ Device. Connect and measure immediately!

Fiber Optic Distributed Temperature Sensor (B-DTS)

Process gases for analytical applications

NGSS Data Consolidator (DC)

Permissible ambient temperature Operation Storage, transport

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

REAL-TIME DUST AND AEROSOL MONITORING

How is Dew Point Measured Reliably?

Chassis, Power Supply, and Element Management

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

Multi-Range Programmable DC Power Supplies 9115 Series

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Regards from the Team at Rheology Solutions.

HTO-1000 Thermal Oxidiser User Manual Version: 1.5

Combustible Gas Safety Monitoring: Infrared vs. Catalytic Gas Detectors

RECON-4 Portable Multi-gas Detector Software Manual

THE DETECTION OF GREENHOUSE GASES

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

Transcription:

Series 8900 Product Series 8900 Gas Chromatograph Multipurpose Gas Chromatograph Monitor single or multiple gas components Applications Well logging - Fast C1-C5 Area monitoring of toxic gases for industrial hygiene and safety - Ethylene Oxide, Acrylonitrile, Butadiene, Styrene, Epichlorohydrin and many others Fenceline (perimeter) monitoring around industrial and remediation sites - BTEX and other VOC's Scrubber efficiency - Hydrocarbons and VOC's Carbon bed breakthrough detection - Solvents and organic compounds Quality Assurance Monitoring, contaminant analysis or blending of industrial gases Methane/Non-methane analysis A list of over 200 detectable gases is available upon request Features & Benefits Accurate & specific to a wide variety and range of gases Continuous unattended operation Operates with or without a computer Automatic calibration and baseline correction for long term stability Outputs include digital, user definable analog and user definable logic PC based SkyChrom software stores multiple analytical methods and chromatograms Multipoint sampling options Onboard short-term data storage Online gas analysis over a broad range of concentrations The Baseline Series 8900 GC is microprocessor based and contains powerful embedded firmware. There are a variety of state of the art detector, calibration and gas train options offering the flexibility and precision necessary to analyze from sub-parts per billion (sub-ppb) to percent levels. The 8900's automatic calibration is ideal for unattended operation. It can be set up on a bench-top or rack-mounted, and its compact size makes it transportable. There are a variety of industry standard outputs, such as network (LAN), RS232, multiple 4-20 ma or 0-20 ma, and multiple relays for concentration alarms, diagnostics or user specified timed events. Gas chromatography applications are factory pre-configured to enable easy start up and operation. The computer can be disconnected and the analyzer will operate independently. When connected to SkyChrom, data can be collected in a universal text format with a user definable data export utility for custom reports. Chromatograms can be stored continuously or based on events such as alarms. Detector options include Photoionization Detector (PID), Flame Ionization Detector (FID) and Thermal Conductivity Detector (TCD).

Specifications Detectors Relay Outputs Analog Outputs Digital Outputs Optional Outputs Inputs Display Software Columns Valves Detector Sampling Samplers Calibration Power Photoionization (PID) 10.6 ev or 11.7 ev High-sensitivity (PID) <50ppt Benzene Flame Ionization (FID) Thermal Conductivity (TCD) Consult Baseline for other options Series 8900 Gas Chromatograph Standard - 5 programmable (latched/not, NE/ NNE, NO/NC) as contact closure (1A @ 30Vdc) Standard - 1 0-20mA or 4-20mA isolated Standard - RS-232, LAN Analog output board - up to 20 additional programmable 4-20 ma outputs Voltage outputs - 0-1 V, 0-5 V or 0-10 V (others on request) Relay board - up to 32 additional programmable relays Optional digital input board for 3 contact closure inputs. Supports start analysis, start calibration, and analyze calibration gas as sample Digital vacuum fluorescent, 20 characters x 2 lines SkyChrom external integration, GC setup and data acquisition software for PC Packed or Capillary / application specific Standard: (1) 10-Port valve (additional valves optional) Single or dual detector Single point analyzer for pre-filtered ( 0.1 microns), non-condensing samples Internal 4, 8, 16 point sampling options (not available on an FID) Built-in or external sample pump Injection port (on sample loop) 8950 Multipoint Sampler (4/8/16 pt) w/ up to 16 analog outputs & 32 relays Automatic or Manual using a dedicated standard 90-260 VAC, 50/60Hz Physical Characteristics Dimensions 3u, 17.41"(44.2cm) W x 9.36"(23.8 cm) D x 14.83"(37.7cm) H Weight 30 lb (13.64 kg) Configuration Bench-top or rack-mount 19"(48.3cm) panel Operating Temperature 32-104 F (0-40 C) Connections 1/4"(6.35mm) tube fitting connectors or consult Baseline Operating Humidity 0-95% (non-condensing) MOCON and Baseline are registered trademarks of MOCON, Inc.. Other trademarks are those of their respective holders. Brochure: D010.2 P.O. Box 649, 19661 Highway 36 Lyons, CO 80540 P: 1.800.321.4665 1.303.823.6661 F: 303.823.5151 E: info@baselineindustries.com www.baselineinc.com

NonMethane Hydrocarbon Analyzer Product Series 9000NMHC Analyzer Accurate and Reliable Methane / Non-Methane Hydrocarbon Analysis over a Broad Range of Concentrations Continuous Monitoring of Methane and Non-Methane Hydrocarbons in Non-Condensing Gases Applications Ambient Air Monitoring Networks Clean Rooms Air & Oxygen Purity in Air Separation Plants Features & Benefits Hydrocarbon Detection from sub-ppm to 1000 ppm (Methane) Flame Ionization Detector Graphical Display with Easy to use Menu System Sleek Rack Mountable Profile Internal, Multipoint Sampling Option Automatic Calibration at User-Defined Intervals FlowGuard Electronic Control of Fuel, Air and Sample Electronic Back-Pressure Regulator with Sample Bypass System Discrete, multilevel concentration & fault alarms Programmable Analog Output Ranges Programmable Relays for Concentration, Alarms, Events and Diagnostics Automatic FID (Flame Ionization Detector) Ignition Automatic Shut-off of Sample, Fuel and Combustion Air Remote Operation via RS-232 and Ethernet Optional: 9000 Keeper Software allows for Remote Monitoring and Control Continuous and Fully Automated Gas Analysis As part of the Baseline Series 9000 Hydrocarbon Analyzer family, the 9000 NMHC is designed to measure the total hydrocarbons, methane and non-methane hydrocarbon content in gas samples. Output options include analog, digital and logic capabilities. The detector used is a FID (Flame Ionization Detector) and an oxidation catalyst that is switched in and out of a portion of the sample stream. The catalyst oxidizes all hydrocarbons except methane, for a methane measurement. The methane value is then automatically subtracted from the total hydrocarbon concentration to determine the non-methane hydrocarbon reading. The Series 9000 NMHC can be configured with internal components for single or multipoint analysis of non-condensing gas samples. The automatic calibration feature enhances the long-term analytical stability of the instrument. These features place the instrument well ahead of the competition in performance, automation and configurability.

Specifications Detector Oxidizer Ranges Repeatability Drift Response Time Alarms Sampling Calibration Support Gas Power Relay Outputs Analog Outputs Digital Outputs Series 9000NMHC NonMethane Hydrocarbon Analyzer (FID) Flame Ionization Detector Oxidizes NonMethane Hydrocarbons User definable based upon calibration within; MDQ 0.06 ppm, Full-scale 1-200 ppm (Air Balance) MDQ 0.1 ppm, Full-scale 1-1,000 ppm (Air Balance) MDQ 0.03 ppm, Full-scale 1-200 ppm (O Balance) +/- 1% Full-scale response +/- 1% of full-scale over 24 hours < 30 seconds to 90% of final reading Multilevel concentration and fault alarms that result in audible and visual alarms Alarms may also be mapped to relays to control external equipment Internal single module for pre-filtered (<0.1 microns) non-condensing samples, with or without sample pump Programmable automatic or manual calibration Hydrogen 35 cc/min (H 2 He Blend 100 cc/min) Air 175 cc/min (typical) Hydrocarbon content must be less than 1 ppm Fuel blend options available, consult Baseline 90-230 VAC, 50/60Hz, 3A 5 programmable form A relays rated to 3A @ 230V AC (optional additional 9 relay output board) 1 programmable 0-20mA or 4-20mA isolated output (optional additional 3 analog output board) RS-232, Ethernet FrontView SideView Mensions are Displayedin inches BackView Phsical Characteristics Dimensions 3u, 19.00"(48.3cm) W x 14.25"(36.2cm) D x 5.25"(13.3cm) H Weight < 20 lb Configuration Bench-top or rack-mount 19"(48.3cm) panel Operating Temperature 32-104 F (0 Connections 1/4"(6.35mm) tube fitting connectors Operating Humidity 0-95% (non-

Total Carbon Analyzer Product Series 9000TCA Analyzer Accurate and Reliable Analysis of Total Hydrocarbons and Total Carbons Fully Automated Analysis over a Broad Range of Concentrations Applications Hydrocarbon and CO / CO 2 impurities in ultra pure inert gases with no oxygen content - Argon - Helium - Hydrogen - Nitrogen Continuous and Fully Automated Gas Analysis Features & Benefits Flame Ionization Detector Graphical Display with Easy to use Menu System Sleek Rack Mountable Profile Automatic Calibration at User-Defined Intervals FlowGuard Electronic Control of Fuel, Air and Sample Electronic Back-Pressure Regulator with Sample Bypass System Discrete, multilevel concentration & fault alarms Programmable Analog Output Ranges Programmable Relays for Concentration, Alarms, Events and Diagnostics Automatic FID (Flame Ionization Detector) Ignition Automatic Shut-off of Sample, Fuel and Combustion Air Remote Operation via RS-232 and Ethernet Optional: 9000 Keeper Software allows for Remote Monitoring and Control As part of the Baseline Series 9000 Hydrocarbon Analyzer family, the 9000TCA has a dynamic range from 0.1 ppm to 100 ppm and is designed to measure total hydrocarbon content and provide a combined carbon monoxide (CO) and carbon dioxide (CO 2 ) reading. The analyzer has a generous complement of analog, digital and logic output capabilities. The detector used is a FID (Flame Ionization Detector) along with a reduction catalyst that is switched in and out of the sample stream. Total hydrocarbons are first measured and the catalyst converts the CO & CO2 to methane and leaves the hydrocarbons unchanged for a total carbon measurement. The total hydrocarbon value is then automatically subtracted from the total carbon concentration to determine the combined CO /CO2 reading. The Series 9000TCA can be configured for single or multi point analysis. The automatic calibration feature enhances the long-term analytical stability of the instrument. These features place the instrument well ahead of the competition in performance, automation and configurability.

Specifications Series 9000TCA - Total Carbon Analyzer Detector (FI ID) Flame Ionization Detector Methanizer Converts low levels of CO and CO 2 to methane Ranges User definable based upon calibration within 0-100 ppm MDQ 0.1 ppm Repeatability +/- 1% Full-scale response Drift +/- 1% of full-scale over 24 hours Response Time T90 < 30 seconds Alarms Mu ultilevel concentration and fault alarms that result in audible and visual alarms s. Alarms may also be mapped to relays to control external equipment Sampling Internal single or multi-point modules for pre-filtered (<0.1 microns), non-condensinthout samples, with or sample pump wit Calibration Pro rogrammable automatic or manual calibration Support Gas Hy ydrogen 40cc/min, Air 200 cc/min (typical). Hydrocarbon content must be less s than 1 ppm. Fuel blend options ava vailable, consult Baseline Power 90-230 VAC, 50/60Hz, 3A Relay Outputs 5 programmable form A relays rated to 3A @ 230V AC (optional additional 9 rela ay output board) Analog Outputs 1 programmable 0-20mA or 4-20mA isolated output (optional additional 3 ana alog output board) Digital Outputs RS-232, Ethernet FrontView SideView Dimensions are displaye yed in inches BackView Physical Characteristics Dimensi 3u, 19.00"(48.3cm) W x 14.25"(36.2cm) D x 5.25"( "(13.3cm) H Weight < 20 lb (9.07kg) Configura Bench-top or rack-mount 19"(48.3cm) panel Operating Temperature 32-104 F (0-40 C) Connecti 1/4"(6.35mm) tube fitting connectors Operating Humidity 0-95% (non-condensing g)