The Versatile Application for In-situ Lift-out TEM Sample Preparation by Micromanipulator and Nanomotor

Similar documents
DualBeam Solutions for Electrical Nanoprobing

Nanoscale Resolution Options for Optical Localization Techniques. C. Boit TU Berlin Chair of Semiconductor Devices

Evaluation of combined EBIC/FIB methods for solar cell characterization

Lecture 030 DSM CMOS Technology (3/24/10) Page 030-1

Ion Beam Sputtering: Practical Applications to Electron Microscopy

Mass production, R&D Failure analysis. Fault site pin-pointing (EM, OBIRCH, FIB, etc. ) Bottleneck Physical science analysis (SEM, TEM, Auger, etc.

The Focused Ion Beam Scanning Electron Microscope: A tool for sample preparation, two and three dimensional imaging. Jacob R.

Physics 25 Exam 3 November 3, 2009

h e l p s y o u C O N T R O L

Nanometer-scale imaging and metrology, nano-fabrication with the Orion Helium Ion Microscope

Development of New Inkjet Head Applying MEMS Technology and Thin Film Actuator

AMD AXDA3000DKV4D Athlon TM XP Microprocessor Structural Analysis

Winbond W971GG6JB-25 1 Gbit DDR2 SDRAM 65 nm CMOS DRAM Process

X-ray thin-film measurement techniques

Physics 441/2: Transmission Electron Microscope

Usage of Carbon Nanotubes in Scanning Probe Microscopes as Probe. Keywords: Carbon Nanotube, Scanning Probe Microscope

Exploring the deposition of oxides on silicon for photovoltaic cells by pulsed laser deposition

CSCI 4974 / 6974 Hardware Reverse Engineering. Lecture 8: Microscopy and Imaging

Chapter 22: Electric motors and electromagnetic induction

Silicon-On-Glass MEMS. Design. Handbook

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

X-ray diffraction techniques for thin films

Lapping and Polishing Basics

Welding of Plastics. Amit Mukund Joshi. (B.E Mechanical, A.M.I.Prod.E)

Demonstration of sub-4 nm nanoimprint lithography using a template fabricated by helium ion beam lithography

The Basics of a Rotary Table with Cross Slide mounted on a Mill Table, Version 2

Smart Card Security How Can We Be So Sure?

The DC Motor. Physics 1051 Laboratory #5 The DC Motor

Bending, Forming and Flexing Printed Circuits

PLASMA TECHNOLOGY OVERVIEW

Winbond W2E512/W27E257 EEPROM

The purposes of this experiment are to test Faraday's Law qualitatively and to test Lenz's Law.

Advanced VLSI Design CMOS Processing Technology

A Remote Plasma Sputter Process for High Rate Web Coating of Low Temperature Plastic Film with High Quality Thin Film Metals and Insulators

Ampere's Law. Introduction. times the current enclosed in that loop: Ampere's Law states that the line integral of B and dl over a closed path is 0

Defense Technical Information Center Compilation Part Notice

Scanning Electron Microscopy tools for material characterization

Sputtering Targets for Microelectronics. Sputtering Targets for Semiconductor Applications

Graduate Student Presentations

Ultrasonic Wave Propagation Review

Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications

. Tutorial #3 Building Complex Targets

J H Liao 1, Jianshe Tang 2,b, Ching Hwa Weng 2, Wei Lu 2, Han Wen Chen 2, John TC Lee 2

12. FIB. Marco Cantoni 021/ Centre Interdisciplinaire de Microscopie Electronique CIME. Focused Ion Beam

Pro/ENGINEER Wildfire 4.0 Basic Design

Wafer Placement Repeatibility and Robot Speed Improvements for Bonded Wafer Pairs Used in 3D Integration

X-Ray Study of Soft and Hard Magnetic Thin Films

Coating Technology: Evaporation Vs Sputtering

histaris Inline Sputtering Systems

Field Application Note

Pulsed laser deposition of organic materials

E/M Experiment: Electrons in a Magnetic Field.

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Micron MT29F2G08AAB 2 Gbit NAND Flash Memory Structural Analysis

Solar Photovoltaic (PV) Cells

HSeries. High Power High Quality. Ultra-High Speed, Sensing Ionizer SJ-H Series

SEM/FIB Workbench. Klocke Nanotechnik. Microtechnology Network. Motion from the Nanoworld. One of 279 members in a. Pascalstr. 17 Aachen, Germany

Syntactic Foam - A New Dielectric

Good Boards = Results

Keeping Current to Stay Competitive in Flex PCB Laser Processing

VCR Ion Beam Sputter Coater

Leica EM SCD500. High Vacuum Sputter Coater For Highest Resolution FE-SEM Analysis

Copyright 2011 Casa Software Ltd. Centre of Mass

ELECTRIC FIELD LINES AND EQUIPOTENTIAL SURFACES

Le nanotecnologie: dal Laboratorio al Mercato. Fabrizio Pirri Politecnico di Torino Istituto Italiano di Tecnologia

CATIA Functional Tolerancing & Annotation TABLE OF CONTENTS

View of ΣIGMA TM (Ref. 1)

Forensic Science: The Basics. Microscopy

Improved Contact Formation for Large Area Solar Cells Using the Alternative Seed Layer (ASL) Process

Embedded Integrated Inductors With A Single Layer Magnetic Core: A Realistic Option

MEMS mirror for low cost laser scanners. Ulrich Hofmann

Focused Ion beam nanopatterning: potential application in photovoltaics

GP-B Telescope Measurement of Telescope Field of View P0454 Rev -

7. advanced SEM. Latest generation of SEM SEM

Application Report: Running µshape TM on a VF-20 Interferometer

Low- Cost Chip Microprobing

Lecture 11. Etching Techniques Reading: Chapter 11. ECE Dr. Alan Doolittle

TopSky DLG Installation Manual

Refraction of Light at a Plane Surface. Object: To study the refraction of light from water into air, at a plane surface.

Analysis of Blind Microvias Forming Process in Multilayer Printed Circuit Boards

Agilent Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

The connector we use most in joining beams is the Technic pin. The Technic pin comes in several variants, as shown in Figure 1 below.

Balzers Sputter Coater SCD 050

A Novel Flex Circuit Area-Array Interconnect System for a Catheter-Based Ultrasound Transducer

Thin Lenses Drawing Ray Diagrams

Lecture 6 Scanning Tunneling Microscopy (STM) General components of STM; Tunneling current; Feedback system; Tip --- the probe.

TOF FUNDAMENTALS TUTORIAL

* This work is an official contribution of the National Institute of Standards and Technology and

Near-field scanning optical microscopy (SNOM)

Conductivity of silicon can be changed several orders of magnitude by introducing impurity atoms in silicon crystal lattice.

Experiment 3 Lenses and Images

METHODS FOR PULSED LASER DEPOSITION OF LARGE-AREA FILMS USING MORE THAN ONE TARGET

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

RS232/DB9 An RS232 to TTL Level Converter

Accurate Air Flow Measurement in Electronics Cooling

Super Cool Sputter Coater

Chapter 14. Printed Circuit Board

SolidWorks Implementation Guides. Sketching Concepts

Polarization of Light

Force on Moving Charges in a Magnetic Field

Transcription:

The Versatile Application for In-situ Lift-out TEM Sample Preparation by Micromanipulator and Nanomotor Jon C. Lee, B.H. Lee Taiwan Semiconductor Manufacturing Company, Ltd., Hsin-Chu, Taiwan Abstract The device features have shrunk to sub-micron/nano-meter range, and the process technology has been getting more complicated, so TEM has become a necessary tool for PFA imaging and element analysis. Conventional FIB ex-situ liftout is the most common technique for precise sample preparation. But this method has some limitations: samples cannot be reprocessed for further analysis; the carbon film supported grid affects the EDS analysis for carbon elements. A new installation will be introduced in this article, which is set up in FIB chamber for in-situ lift-out application. It not only overcomes the above problems, but also covers a wide application of TEM sample preparation. Introduction With the increasing complexity of process technology, device features are down to the deep sub-micron range. Transmission electron microscopy (TEM) has become the most important tool for detailed physical failure analysis and material analysis. The Focus ion beam (FIB) is also a necessity for failure analysis and TEM sample preparation. Ex-situ lift-out TEM sample preparation is to thin the sample by FIB and then transfers TEM lamella to carbon film supported grid by glass needle. It is the most popular method used to prepare TEM samples, but there are two problems with this technique: 1) TEM lamella on carbon film supported grid cannot be used for carbon signal analysis due to the carbon film which will affect the EDS analysis results, 2) it is also difficult to re-thin a TEM sample that has lain on a carbon film for further analysis (EELS, HRTEM). So an insitu lift-out technique was developed to overcome these drawbacks. Several commercial in-situ lift-out tools [1,2] are usually used for cross sectional TEM sample preparation. It lifts-out the sample and then attaches the sample to a half-cut copper grid inside the FIB chamber. For planar sample preparation and re-thinning of the TEM sample that has been put on a carbon film, the user must unload the copper grid with sample from the chamber and then reload it into the FIB chamber at a perpendicular angle for final milling. This increases the preparation time and risk of sample damage. In this article, a novel in-situ lift-out tool will be introduced. It consists of a micromanipulator and a nanomotor, which can be easily installed into a FIB and does not have the drawback of the commercial tool mentioned above. Several applications of sample preparation will also be discussed such as lifting-out lamella from carbon film supported grid for further sample re-thinning to get element mapping by GIF, planar TEM sample preparation, and preparing samples for 3D TEM observation. Tool Setup This lift-out toll was set up in a FEI DB235, and it includes two key components: a Kleindiek MM3A micromanipulator and a Kleindiek rotational nanomotor (Fig. 1). The MM3A has two rotation axes and one linear axis. A tungsten needle can be inserted into the end of linear axis for lift-out. A TEM MM3A Micromanipulator Adaptor plate Nanomotor Figure 1: A MM3A manipulator and a nanomotor are installed on an adaptor plate, which can be set up and removed easily. grid end-effector connects to nanomotor and can clamp a half-cutt TEM copper grid to attach the lamella (Fig. 2). The nanomotor can rotate 360 ο. It is easy to orient the lamella to any direction with respect to the ion beam for further FIB milling so different kinds of TEM samples can be prepared by this tool without breaking vacuum. In addition, this tool is very compact. It is very easy to install and remove, and the

360 o Figure 2: A TEM grid end-effector (micro tweezers) clamps a half-cut copper grid and inserts into nanomotor. Cut the sample edge to separate W tip from lamella (Fig. 4d). Rotate Cu grid by nanomotor to parallel the sample to the ion beam for further milling (Fig. 4e). This is a very unique function of this tool; which makes the sample prepared without breaking vacuum. FIB re-thins the both sides of lamella (Fig. 4f). Figures 4gand 4h show the TEM image and further GIF analysis. If a STEM detector is installed, STEM image is possible to be observed. This work has been going on in our Lab. Figure 3: Control cable connects to a chamber port. Figure 4a: FIB pre-cut carbon film, and then inserts W needle beside lamella. tungsten needle replacement is also easy and quick. Figure 3 shows that only one electric cable is needed for tool control. Sample Preparation Procedure Re-thin a TEM Lamella Lain on a Carbon Film It is very difficult to re-thin a lamella lain on a carbon film for further analysis like taking high resolution image or EELS analysis by a conventional ex-situ lift-out method. There is a paper that discusses a method to do this kind of preparation [3], but it is risky and not easy. By using this novel tool, one can do this work easily. The preparation steps are described below: Attach the lamella lain on a carbon film supported grid to FIB stage. Find the sample and use low ion beam current to pre-cut carbon film a little bit, then insert tungsten needle beside the sample (Fig. 4a). Stick the sample corner to tungsten (W) tip by using FIB induced platinum (Pt) deposition. Cut the carbon film around the sample so the W tip with lamella is free from the original copper grid. Lift-out the TEM lamella (Fig 4b). Move the FIB stage to center the half-cut Cu grid that is clamped by TEM grid end-effector (Fig. 4c). Insert the W tip with TEM lamella beside the half-cut Cu grid. In this step, the grid is perpendicular to the ion beam. FIB Pt deposition for lamella bonding to Cu grid. Figure 4b: Cut the carbon film around the sample and Lift-out lamella from carbon film. Figure 4c: Center the half-cut copper grid by moving the stage of the FIB.

Figure 4d: Cut the sample edge to Separate W tip. Figure 4h: GIF oxygen element mapping shows abnormal oxygen layer beneath the contact bottom, which induced high resistance. Planar TEM Sample Preparation The traditional technique for planar TEM sample preparation is time-consuming. This tool can be used for this application easily and quickly. Figure 4e: Rotate nanomotor to parallel the sample to the ion beam for re-thinning. Figure 4f: FIB re-thins both sides of lamella to make a thinner sample for further analysis. The preparation steps are described as below: Deposit a platinum protective layer on the specific area. Mill the front and back edge of the area at zero tilt. So the bottom of the triangular bulk is free from the substrate (Fig. 5a). Cut the right sidewall of the triangular bulk. Stick the sample corner to W tip by using FIB Pt deposition. Cut the left sidewall of the bulk so the W tip with the bulk specimen is free from the substrate completely. Then liftout the sample (Fig. 5b). Move the FIB stage to center the half-cut TEM Cu grid. The following steps are the same as the procedure for rethinning a lamella lain on carbon film. Stick the sample to half-cut Cu grid and cut the sample edge to separate the W tip from the sample (Fig. 5c). Rotate the Cu grid 90 degree. FIB mills both sides of the bulk sample (Fig. 5d). Figure 5e shows the planar TEM image. Figure 4g: TEM image of the re-thinning sample in Fig. 4f. Figure 5a: FIB pre-cut front and back edge of the interested area at zero tilt.

Reprocess a TEM Lamella from Carbon Film for 3D Observation A defect is not always easy to be precisely located to make a cross-section TEM. So, the sample needs to make plane view TEM observation first to locate the exact defect position, and then make a precise cross-section. Sometimes the physical information of a defect is not provided sufficiently by TEM observation in only one direction. The 3D information of the defect (plane view and cross-section, X and Y direction cross-section) becomes necessary to judge the failure root cause of the problem [4]. Figure 5b: Lift-out the bulk sample from the substrate after sidewalls cutting. Figure 5c: Stick the sample to half-cut Cu grid and cut the sample corner to separate the W tip from the sample. The following procedure will describe the sample preparation method using the in-situ lift-out tool for 3D observation: Get an X direction cross-section TEM image (Fig. 6a). Attach the carbon film supported copper grid to FIB stage. Pre-cut carbon film a little bit and insert W needle beside the sample. Stick the sample corner to W tip by using FIB Pt deposition. Cut the carbon film around the sample. Lift-out the TEM lamella (Fig. 6b). Center the TEM half-cut grid. Insert W tip with TEM lamella beside half-cut Cu grid. The grid is always parallel to the ion beam in this method. Pt deposition for lamella bonding to Cu grid. Cut the end of W tip to separate W tip from lamella. Pt deposition on the sample to protect the target (Fig. 6c). FIB mills both sides to approach the target (Fig. 6d). Figure 6e, 6f show a further Y direction cross-section TEM image of sample in Fig. 6a. Figure 5d: FIB mills both sides to make a final planar TEM sample. Figure 6a: An X direction cross-section STEM image shows a poly defect in Si substrate, but the image provides insufficient information to judge the failure root cause. Figure 5e: TEM image of the sample in Fig. 5d. The X direction cross-section image shows a defect under poly, but it is hard to judge when and how the defect formed depending on the less information. If this is the only sample, then there will be no chance to make another direction TEM sample to collect more data. This tool easily makes it possible to prepare Y direction cross-section sample from the original X direction cross-section sample. Figure 6e, 6f

Figure 6b: Cut the carbon film around the sample then Lift-out the lamella. Spacer Figure 6c: Stick the sample to half-cut Cu grid, then cut the sample corner to separate the W tip from the sample. Figure 6e, 6f: Further Y direction cross-section TEM image of sample in Fig. 6a shows the substrate damage is due to L spacer etching. demands. All preparation procedures are carried out without breaking vacuum. It also has some advantages: 1) it is compact and easy to be installed and removed, 2) tungsten needle can be replaced easily and quickly, 3) it is cheap, 4) it can be set up to existing FIB. This tool has already been widely used for difficult case handling in our lab. References Figure 6d: FIB mills both sides to approach the target in Y direction. are the TEM image taken from another direction, which clearly shows the substrate damage is due to spacer etching. [1] AutoProbe, Omniprobe Inc., Dallas, TX [2] Xtreme Access, Ascend Instrument, Beaverton, OR [3] Nathan Wang, Jin Wu, Sabbas Daniel, Grafting FIB Liftout TEM Sample for Further Ion Milling and Its Application for Semiconductor Device, Proceedings of ISTFA (2004) [4] Jon C. Lee, David Su, J. H. Chuang, A Novel Application of the FIB Lift-out Technique for 3-D TEM Analysis, Microelectronics Reliability, Vol. 41, No. ER9-0, p1551, 2001 Conclusions A novel in-situ lift-out installation consists of a micromanipulator and a nanomotor with TEM grid endeffector was set up in a dual-beam FIB for TEM sample preparation. This tool was used to demonstrate several kinds of sample preparation successfully for TEM analysis