Product Datasheet NK8237 Modbus Gateway for Sinteso and Cerberus PRO fire detection systems

Similar documents
Input module, input/output module

FC722 Fire control panel

PCS0100en Persy Control Services B.V. Netherlands

IntesisBox Modbus Server Fidelio IP

FC722. Fire control panel. Cerberus PRO. FS720 series, IP6

Temperature & Humidity SMS Alert Controller

Fire control panel (modular)

Telephone- and leased line modem for industrial applications TD-36

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

SMS GSM Alarm Messenger

IntesisBox KNX Modbus TCP master

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

Repeaters and Mimics Data Sheet

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

Application/Connection Examples

IntesisBox Modbus Server SAMSUNG Air Conditioners

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Product Information Fire alarm panel 8000 C

IntesisBox KNX Mitsubishi Heavy Industries AC

Rack mounted telephone- and leased line modem for industrial applications

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

TrueAlarm Fire Alarm Systems

Cerberus PRO product catalog

Application Server V240 Platform

Modbus Server SAMSUNG Air Conditioners

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

User Manual. EtherUSB

KNX Panasonic Air Conditioners

HyperAccess Access Control System

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

DCS Data and communication server

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

Datasheet. Enterprise Gateway Router with Gigabit Ethernet. Models: USG, USG-PRO-4. Advanced Security, Monitoring, and Management

ZC-24DO CANopen I/O Module: 24 Digital Outputs

IntesisBox ASCII Server - LON

OZW30. Central Unit SYNERGYR

IntesisBox Modbus Server - Mitsubishi Electric G50

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

SECTION DETECTION AND ALARM

Environmental data Temperature: -20 C to +55 C (Operating) -55 C to +85 C (Storage) Humidity: 0 95%

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Pano Device. Data Sheet. How It Works: Key Benefits:

connecdim Gateway G1 Ethernet TCP/IP to DALI

A-307. Mobile Data Terminal. Android OS Platform Datasheet

Unidirectional Transmitter/ Receiver Units Introduction

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

xpico Wi-Fi Embedded Device Server Evaluation Kit Quick Start Guide

IntesisBox KNX Modbus RTU master

Rev GSM base station. Installation instructions

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

CX Series. Video Recording Server. Quick Start Guide CX784 / CX788 / CX7816. Version

User Manual Revision English

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

3500/22M Transient Data Interface

SNMP Web Management. User s Manual For SNMP Web Card/Box

OPTICAL FIBER repeaters/ isolators

TX OPEN RS232/485 module

Waveguide Access Point WGA631. Product Guide

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

TK C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W. TK-Series Cellular Router

NGSS Data Consolidator (DC)

USR-TCP232-T Hard Version: V2.0 Doc Version: V

Datasheet. Advanced Network Routers. Models: ERPro-8, ER-8, ERPoe-5, ERLite-3. Sophisticated Routing Features

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS


Chassis, Power Supply, and Element Management

Loop-IP6702 TDMoEthernet

Phase Modular Finally the benefits of Modular ups are for all

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Alert, inform, react Aastra Alarm Server

SCADAPack 530E 535E. remote Programmable Automation Controller

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Emerson Smart Firewall

8-Port HDMI Switch USER MANUAL VS0801H

DSX Master Communications

Technical description MX-1 VB Edge

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

SHEET. BASautomation. BAS Router BACnet Multi-Network Router. BAS Router

Multi-Range Programmable DC Power Supplies 9115 Series

Disturbance Recoder SPCR 8C27. Product Guide

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Always on the Lookout Perfect Protection against Burglary

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

AXIS 262+ Network Video Recorder

Long Reach PoE over Coaxial Extender Kit

Communicate and view data from meters with one simple device

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

User Manual Revision English

T3 Mux M13 Multiplexer

IntesisBox. Making Building Automation go further. Modbus Products

Transcription:

Product Datasheet NK8237 Modbus Gateway for Sinteso and Cerberus PRO fire detection systems The NK8237 is used as a gateway between Sinteso (or Cerberus PRO) fire detection systems, and Modbus head-end/automation systems on LAN or over a serial line. It provides for bi-directional Modbus RTU and TCP/IP connectivity to Sinteso or Cerberus PRO fire detection systems. NK8000 MP4.50 Cost-effective Modbus gateway for FS20 Sinteso or FS720 Cerberus PRO fire detection systems. Up to 4 FC20xx/FC72x control units in Ethernet topologies. Up to 16 units in SAFEDLINK topologies or in mixed Ethernet/SAFEDLINK topologies. Modbus over Serial Lines: Modbus slave supporting RTU mode (over RS232 or RS485) on up to two serial lines. Modbus over TCP/IP: Modbus server supporting up to four TCP/IP client connections. Separate Ethernet ports can be used in combination with the built-in firewall for the fire network and Modbus TCP/IP connection for maximum protection of the safety network. Logging capabilities for upstream and downstream communication paths. Simplified FS20/FS720 status information representing fire object conditions organized in Modbus word, bit, and compact tables. Control commands including panel Acknowledgement and Reset as well as individual Include/Exclude commands. Easy PC configuration based on Composer GW Tool (no license required) or standard DMS8000 tools. Fast import of FS20/FS720 object configurations (SiB-X file) and customizable default mapping for a flexible and efficient Modbus interface definition. Standard RoHS compliant NK8000 hardware equipped with watchdog and diagnostics LEDs. Supplied in a plastic box for easy installation on DINrails. Optional housing solutions with autonomous and supervised power supply. SNMP protocol support for administrative management.

Connectivity examples Single FC20 control unit with Modbus Serial RTU (max. 2 ser. connections) Single FC20 control unit with Modbus TCP/IP (up to 4 Modbus clients) 2 FCnet SAFEDLINK network with Modbus Serial RTU and Modbus TCP/IP (up to 4 Modbus connections in total)

Connectivity specifications Modbus Modbus serial (master) (NK8237 is Modbus slave) AND/OR Modbus TCP/IP (client) (NK8237 is Modbus server) RS485 or RS232 Modbus RTU mode (1 link per serial line, max. 2 serial lines) Master supports multiple slaves on RS485 1200 to 115K baud, default is 19200 DB9 female (RS232) Screw connector (RS485) Ethernet 10/100 Base-T (up to 4 links) RJ-45 connector Fire control units 1 FS20 Sinteso BACnet/IP (NK8237 is BACnet client) FC2020 FC2030 FC2040 FC2060 FC2080 FT2040 Stand-alone (1 unit) FCnet/Ethernet (max. 4 units) FCnet/SAFEDLINK (max. 16 units) Mix Ethernet/SAFEDLINK (max. 16 units) RJ-45 connector FS720 Cerberus PRO BACnet/IP (NK8237 is BACnet client) FC722 FC724 FC726 FT744 Stand-alone (1 unit) C_WEB/Ethernet (max. 4 units) C-WEB/SAFEDLINK (max. 16 units) Mix Ethernet./SAFEDLINK (max. 16 units) RJ-45 connector Total detectors Max 10,000 physical elements Note: Detector limit dependent on number of Modbus hosts. See FS20/FS720 system limits for NK8000 Modbus host connectivity p. 4 for details. Modbus functions and fire unit representation Monitoring 0x02 Read Discreet Input Bit tables 1-bit (on/off) for alarms, faults, and other events 0x04 Read Input Register Compact tables 2-bit (for fire detectors) and 4-bit (for fire zones) status 0x04 Read Input Register Status tables 16-bit rich status for all supported objects 0x03 Read Holding Register Date/Time Command tables Day / Month, Year / Hour, Minute / Seconds Latest command: Ack, Reset, Manned/Unmanned; On/Off Controlling 0x06 Write Single Register Date/Time Command tables Day / Month, Year / Hour, Minute / Seconds Ack, Reset, Manned/Unmanned; On/Off (Include/Exclude) Supervising 0x07, 0x08, 0x0B, 0x11 Serial line status Various functions for serial line supervision 0x2B, 0x0E Read device ID General NK8237 information Technical data Power supply Input voltage (DC power supply to NK8237) 10-33 Vdc Digital Inputs Power consumption (including DF8090) NE8001 3 inputs for power supply supervision or other purposes E.g. for supervision of FP2003-A1 or FP2004-A1 Power supply kits 5 W 100-240 Vac, 50/60Hz NO or NC dry contacts or open collector signals Max forward current: 7 ma at 33Vdc Over voltage protection on input lines: 1K V Input voltage limit: 33V Relay Output Modbus communication fault NO or NC relay contacts, Max 1A at 30 Vdc Operating conditions Temperature range 0 to 50 C Humidity 10 to 95 % non condensing Dimensions NK8237 board W x H [mm] 160 x 100 (Euro-size PCB) NK8237 plastic housing for DIN-rail W x H x D [mm] 180 x 108 (excluding connectors) x 80 NK8237 in NE8001 / wall-mounted W x H x D [mm] 385 x 450 x 150 Weight NK8237 in plastic housing for DIN-rail 0.420 Kg NK8237 in NE8001 8.5 Kg (fully equipped) 1 Each station needs to be equipped with a FCA2013-A1 License key L2 (A5Q00018857) to enable the BACnet protocol. 3

Administrative tools Download Logging SNMP support Two download modes for configuration data transfer from the configuration station Upstream and downstream communication can be logged on a USB mass storage device Provides 2 sets of information variables using the community IDs Public: A basic set of information Engineer: Access to the complete set of information Standard download mode based on FTP protocol (default) Secure download mode supporting authentification and encryption Log files can be uploaded from remote Firewall Firewall functionality Preconfigured firewall configurations can be selected: Standalone FW (no routing between ETH1 and ETH2) Edge FW (ETH1 as external network, routing between ETH1 and ETH2 enabled) Edge FW (ETH2 as external network, routing between ETH1 and ETH2 enabled) Regulatory approvals EN 61000-6-3 EN 50130-4 EN 60950-1 FCC Part 15 Class B EMC emission EMC immunity LVD (installed in NE8001) EMC emission FS20/FS720 system limits for NK8000 Modbus host connectivity 1 host Max. 10,000 detectors and 16 FS20/FS720 units in FCnet/SAFEDLINK topology or 4 units in 2 hosts Max. 5,000 detectors and 8 FS20/FS720 units in FCnet/SAFEDLINK topology or 4 units in 3 hosts Max. 3,500 detectors and 6 FS20/FS720 units in FCnet/SAFEDLINK topology or 4 units in 4 hosts Max. 2,500 detectors and 4 FS20/FS720 units in FCnet/SAFEDLINK topology or 4 units in Software Engineering Tool Composer GW Tool DMS8000 Composer MP4.50 No license required License required 2 Windows XP / Vista / 7 Pentium 4 PC, 1 GB RAM DF8090 Power Supply Supervision Module (option) DF8090 Mains failure (missing 220 Vac) / Battery low / Power supply failure (AC/DC converter) / Battery protection fuse blown Battery fuse is internal to DF8090 plastic box Micro-fuse type: MSF 3.15A/250V Battery: 12V, max 27 Ah Details for ordering S54461-C7-A1 NK8237.2 Modbus Gateway with plastic case A6E600066 NE8001 Wall-mountable, metallic cabinet with DIN-rail and pre-wired electrical units A6E600067 NE8002 Wall-mountable, metallic cabinet with DIN-rail A6E600010 DF8090 Power supply supervision module S54461-B4-A1 NKA8011-A1 Installation plate for NK8237 cards without plastic case 2 A HW key and SW license (either Service-key with annual license fee or Composer license for end customers) is required for DMS8000 Composer. 4

Technical documentation A6V10316239 A6V10316241 A6V10316242 A6V10062401 A6V10062453 NK8237 Installation Sheet NK8237 Installation, Configuration and Commissioning Guide NK8237 Interface Specifications Composer Technical Manual NK8000 Release Notes Disposal This device includes electrical and electronic components and must not be disposed of as domestic waste. Current local legislation must be observed. Export restrictions Cryptographic algorithms Cryptographic export control regulations currently prohibit shipping and installing the NK8237 in the following countries: Cuba, Iran, North Korea, Rwanda, Sudan, and Syria. 5

Siemens Switzerland Ltd Infrastructure & Cities Sector Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41 724 24 24 www.siemens.com/buildingtechnologies 2012 Copyright by Siemens Switzerland Ltd Data and design subject to change without notice. Supply subject to availability. Document no. A6V10316240_a_en_-- NK8000 Sales Material Edition 06.2012 Section 2