IntesisBox. Making Building Automation go further. Modbus Products
|
|
|
- Lindsay Grant
- 9 years ago
- Views:
Transcription
1 IntesisBox Making Building Automation go further Modbus Products October 2008
2 Overview of products Modbus Server (slave) gateways and interfaces designed for integration of third party systems into Modbus based control systems Modbus Slave - Mitsubishi Electric A.C. (Domestic/Mr.Slim series) Modbus Server - Mitsubishi Electric A.C. (City Multi) Modbus Server - BACnet/IP client Modbus Server - LON Modbus Server - KNX / EIB Modbus Server - M-Bus (EN ) Modbus Server - Notifier ID3000 series Modbus Server - Honeywell XLS 80 Modbus Server - ESSER 8007/8008 Modbus Server - Siemens Cerberus (CC11, CC10) ISO 1745 protocol Modbus Server - Siemens FC330A Modbus Server - KILSEN KSA 7xx series Modbus Server - ZITON ZP3 (ZCP2-2 protocol) Modbus Server - ADEMCO Algorinet (BC216-x) Modbus Server - ADEMCO Galaxy (SIA Protocol) Modbus master (client) gateways designed for integration of Modbus devices or systems into other control systems (BACnet, KNX...) KNX - Modbus RTU master KNX - Modbus TCP master BACnet/IP server - Modbus RTU master
3 Modbus Server series Modbus Server (slave) gateways and interfaces designed for integration of third party systems into Modbus based control systems Manufacturers Modbus TCP or RTU Monitoring/Control system BMS SCADA HMI TouchPanel PC PLC Full monitoring and control RS232, RS485 TCP/IP IntesisBox Media RS232 RS485 Ethernet LON TP/FT-10 KNX TP-1 (EIB) Protocols BACnet LonWorks KNX EIB M-Bus Proprietary Systems HVAC Air Conditioning Chillers/Heaters Thermostats Fancoil controllers Room controllers Metering Electricity Meters Energy meters Fire panels Security Daikin Mitsubishi Electric Mitusbishi Heavy Toshiba Fujitsu General LG Trane Kiebak & Peter Merlin Gerin Kamstrup Honeywell Notifier Esser Siemens Cerberus Kilsen Ademco And many others
4 Modbus Slave - Mitsubishi Electric A.C. (Domestic/Mr.Slim series) Ref. ME-AC-MBS-1 Modbus RTU slave interface for Domestic & Mr.Slim (commercial) series of Mitsubishi Electric air conditioners. The ME-AC-MBS-1 interface has been designed in co-operation with Mitsubishi Electric to offer full monitoring/control of Domestic & Mr.Slim series of air conditioners by any Modbus RTU master device. It connects to the Modbus RTU network (RS485 bus) in one side, and directly to the PCB of the A.C. indoor unit in the other side, no external power is required. The cable to connect to the A.C. indoor unit is also included in the scope of delivery of the interface. Each A.C. indoor unit to integrate requires one ME-AC-MBS-1 interface. The interface in mountable on DIN rail, wall, or even inside the A.C. indoor unit in some models. Reduced dimensions 90 x 53 x 58 mm. Easy configuration (slave address, baud rate, A.C. model) by means of Modbus registers as well as on-board DIP-switches externally accessible. Slave address can be from 1 to 254, which means that up to 254 A.C. indoor units can be controlled by a single Modbus master device (repeaters may be required in the RS485 bus for long distances or when more than 32 devices are connected). Simultaneous use of the A.C. IR remote control and the ME-AC-MBS-1 is allowed, the same control functions of the IR remote control are possible with the ME-AC- MBS-1, and some others really useful as for example to stop the unit when the window of the room is open. Fully bi-directional monitoring and control of the A.C. unit: Operation Mode, Set Point and Ambient Temperature, Vane Position, Alarms
5 Modbus Server - Mitsubishi Electric A.C. (City Multi) Ref. ME-AC-MBS-50 / ME-AC-MBS-100 ME-AC-MBS-150 / ME-AC-MBS-200 Modbus gateway for City Multi (professional) series of Mitsubishi Electric air conditioners. The ME-AC-MBS-50/100/150/200 gateway has been designed in co-operation with Mitsubishi Electric to offer full monitoring/control of City Multi (professional) series of air conditioners by any Modbus master or client device (RTU or TCP). It connects directly to the Modbus network in one side, and in the other side it communicates to the City Multi system through the Mitsubishi Electric G-50A or GB- 50A interface. For this integration it is required the Mitsubishi Electric G-50A or GB-50A interface be installed in the City Multi system, the G50 gives access to up to 50 groups of A.C. indoor units. Independent monitoring/control (bi-directional) from Modbus of each group of A.C. indoor units, of multiple parameters (Ambient Temperature, Set Point Temperature, Operation Mode, Fan Speed ). In the City Multi system the control unit is the group of indoor units, and each group can have from 1 to 16 associated indoor units. Nevertheless, individual control of single indoor units is also possible by associating a single indoor unit per each group in the G50. Each IntesisBox model ME-AC-MBS-50, 100, 150 and 200 supports respectively control of up to 50, 100, 150, and 200 groups. All the functions allowed by the A.C. remote control are also allowed from Modbus through the IntesisBox. IntesisBox Modbus Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. Demo configuration files are also supplied for LinkBoxMB with no additional cost, making the configuration of IntesisBox for this integration extremely easy and quick, almost plug & play.
6 INTESIS SOFTW ARE M odbus Products October 2008 Modbus Server - BACnet/IP client Ref. IBOX-MBS-BAC-A / IBOX-MBS-BAC-B Gateway for monitor and control DAIKIN air conditioning systems from Modbus (RTU or TCP) master or client devices (SCADA, BMS, PLC, HMI, TouchPanels ), and in general to monitor/control any BACnet/IP system or device from Modbus. IBOX-MBS-BAC-A and IBOX-MBS-BAC-B have been designed to offer a full integration (monitor and control) of DAIKIN air conditioners from Modbus control systems, specially suited for big installations. The gateway not only allows DAIKIN integration but many other air conditioning brands, and in general integration into Modbus of any BACnet/IP device or system. It connects directly to the Modbus network in one side (RS232, RS485, ETH), and in the other side it communicates via BACnet/IP to the DAIKIN system through the Daikin D-BACS interface. The Daikin D-BACS BACnet interface (ref. DMS502B51) is required to be installed in the Daikin system for this integration. Independent monitoring/control (bi-directional) from Modbus of each DAIKIN indoor unit or group of units, of multiple parameters (Ambient and Set Point Temperature, Operation Mode, Fan Speed ). IBOX-MBS-BAC-A supports up to 500 points and communication to one BACnet/IP device, IBOX-MBS-BAC-B supports up to 3000 points and communication to up to 16 BACnet/IP devices. IntesisBox Modbus Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. Demo configuration files are also supplied for LinkBoxMB with no additional cost, making the configuration of IntesisBox for integration of many brands of air conditioning (DAIKIN, Mitsubishi Heavy, Toshiba, Fujitsu-General ) extremely easy and quick, almost plug & play.
7 Modbus Server - LON Ref. IBOX-MBS-LON-A / IBOX-MBS-LON-B Gateway for monitor and control of DAIKIN air conditioning systems from Modbus (RTU or TCP) master or client devices (SCADA, BMS, PLC, HMI, TouchPanels ), and in general to monitor/control any LON (TP/FT-10) system or device from Modbus. IBOX-MBS-LON-A and IBOX-MBS-LON-B have been designed to offer a full integration (monitoring and control) of DAIKIN VRV air conditioners into Modbus systems, specially suited for small / medium size installations. The gateway not only allows DAIKIN integration but many other air conditioning brands, and in general integration into Modbus of any LON (TP/FT-10) device or system. It connects directly to the Modbus network in one side (RS232, RS485, ETH), and in the other side it communicates via LON (TP/FT-10) to the DAIKIN system through the Daikin DMS-IF interface. The Daikin DMS-IF LonWorks interface (ref. DMS504B51) is required to be installed in the Daikin system for this integration. Independent monitoring/control (bi-directional) from Modbus of each Daikin indoor unit or group of units, of multiple parameters (Ambient and Set Point Temperature, Operation Mode, Fan Speed ). IBOX-MBS-LON-A supports up to 500 points and communication to up to 64 LON devices, IBOX-MBS-LON-B supports up to 4000 points and communication to up to 128 LON devices. IntesisBox Modbus Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. Demo configuration files are also supplied for LinkBoxMB with no additional cost, making the configuration of IntesisBox for integration of many brands of air conditioning (DAIKIN, Mitsubishi Heavy, Mitsubishi Electric, Toshiba, Fujitsu- General, Samsung, LG ) extremely easy and quick, almost plug & play.
8 Modbus Server - KNX / EIB Ref. IBOX-MBS-KNX-A / IBOX-MBS-KNX-B Gateway for monitor and control of KNX EIB installations from Modbus (RTU or TCP) master or client devices (SCADA, BMS, PLC, HMI, TouchPanels ) IBOX-MBS-KNX-A and IBOX-MBS-KNX-B have been designed to offer full monitoring and control of KNX EIB installations from Modbus RTU or TCP master or client devices. It connects directly to the EIB bus in one side, and in the other side it communicates to the monitoring/control system with Modbus RTU or TCP protocol. Allows Modbus TCP (Ethernet) or Modbus RTU (RS232 or RS485) communication, configurable by software. IntesisBox is a server device in case of Modbus TCP communication, or a slave device in case of Modbus RTU communication. IBOX-MBS-KNX-A supports up to 500 points, IBOX-MBS-KNX-B supports up to 3000 points. IntesisBox Modbus Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. Demo configuration files are also supplied for LinkBoxMB with no additional cost, making the configuration of IntesisBox for this integration extremely easy and quick, almost plug & play.
9 Modbus Server - M-Bus (EN ) Ref. IBOX-MBS-MBUS-A / IBOX-MBS-MBUS-B Gateway for the monitoring of M-Bus meters from Modbus (RTU or TCP) master or client devices (SCADA, BMS, PLC, HMI, TouchPanels ) IBOX-MBS-MBUS-A and IBOX-MBS-MBUS-B have been designed to monitor M- Bus meters (EN ) from any Modbus master or client device (SCADA, BMS, PLC ). It connects to the M-Bus system through an external RS232 or RS485 to M-Bus level converter in one side, and in the other side it communicates to the monitoring/control system with Modbus RTU or TCP protocol. Allows Modbus TCP (Ethernet) or Modbus RTU (RS232 or RS485) communication, configurable by software. IntesisBox is a server device in case of Modbus TCP communication, or a slave device in case of Modbus RTU communication. IBOX-MBS-MBUS-A allows monitoring of up to 60 M-Bus meters and a maximum of 600 internal data points, and IBOX-MBS-MBUS-B allows monitoring of up to 500 M- Bus meters and a maximum of 2000 internal data points. IntesisBox Modbus Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. Demo configuration files are also supplied for LinkBoxMB with no additional cost, making the configuration of IntesisBox for this integration extremely easy and quick, almost plug & play.
10 Modbus Server - Notifier ID3000 series Ref. IBOX-MBS-NID3000 Gateway for monitor and control Notifier ID3000 / ID3002 / ID60 / ID50 fire panels from Modbus master or client devices (SCADA, BMS, PLC, HMI, TouchPanels ) Monitor & Control your network of Notifier fire panels remotely from your Control Center using any commercial SCADA or monitoring software with Modbus TCP driver. IntesisBox allows Modbus TCP (Ethernet) or Modbus RTU (RS232 or RS485) communication, configurable by software. IntesisBox is a server device in case of Modbus TCP communication, or a slave device in case of Modbus RTU communication. IntesisBox connects to the RS232 port of the Notifier panel, either through the RS232 port of the mother board, or through the isolated ISO-RS232 port (optional card). Monitoring of the Notifier elements (detectors, outputs ) through independent Modbus registers. The value in the Modbus register indicating the state of the panel's element is fully configurable. Commands toward the panel are also supported (reset, silence, test elements ). Fixed Modbus address map, the register number identifies the element into the Notifier panel. Simple configuration, no point's configuration needs to be entered, just the communication parameters (IP address, baud rate ). One full panel capacity is supported. IntesisBox Modbus Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. The user interface of LinkBoxMB allows simulating the values of the Modbus registers without the need to be physically connected to the panel, very useful while in commissioning phase.
11 Modbus Server - Honeywell XLS 80 Ref. IBOX-MBS-XLS80 Gateway for monitor and control Honeywell XLS 80 fire panels from Modbus master or client devices (SCADA, BMS, PLC, HMI, TouchPanels ) Monitor & Control your network of Notifier fire panels remotely from your Control Center using any commercial SCADA or monitoring software with Modbus TCP driver. IntesisBox allows Modbus TCP (Ethernet) or Modbus RTU (RS232 or RS485) communication, configurable by software. IntesisBox is a server device in case of Modbus TCP communication, or a slave device in case of Modbus RTU communication. IntesisBox connects to the RS232 port of the Honeywell panel, either through the RS232 port of the mother board, or through the isolated ISO-RS232 port (optional card). Monitoring of the Honeywell elements (detectors, outputs ) through independent Modbus registers. The value in the Modbus register indicating the state of the panel's element is fully configurable. Commands toward the panel are also supported (reset, silence, test elements ). Fixed Modbus address map, the register number identifies the element into the Honeywell panel. Simple configuration, no point's configuration needs to be entered, just the communication parameters (IP address, baud rate ). One full panel capacity is supported. IntesisBox Modbus Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. The user interface of LinkBoxMB allows simulating the values of the Modbus registers without the need to be physically connected to the panel, very useful while in commissioning phase.
12 Modbus Server - ESSER 8007/8008 Ref. IBOX-MBS-ESSER Gateway for monitor and control ESSER 8007 / 8008 fire panels from Modbus master or client devices (SCADA, BMS, PLC, HMI, TouchPanels ) Monitor & Control your network of ESSER fire panels remotely from your Control Center using any commercial SCADA or monitoring software with Modbus TCP driver. IntesisBox allows Modbus TCP (Ethernet) or Modbus RTU (RS232 or RS485) communication, configurable by software. IntesisBox is a server device in case of Modbus TCP communication, or a slave device in case of Modbus RTU communication. ESSER IDT protocol, either over RS485 or RS232 serial line is supported. Monitoring of the ESSER elements (detectors, outputs, zones) through independent Modbus registers. The Modbus address map is fully configurable. The states desired to be translated to Modbus are also selectable (0-Normal, 1-Alarm 7-Test). Integration of up to 3000 points is supported by IntesisBox. Commands toward the panel are also supported (reset, disconnect and test of elements ). IntesisBox Modbus Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. The user interface of LinkBoxMB allows simulating the values of the Modbus registers without the need to be physically connected to the panel, very useful while in commissioning phase.
13 Modbus Server - Siemens Cerberus (CC11, CC10) ISO 1745 protocol Ref. IBOX-MBS-CERBERUS Gateway for monitor and control Siemens AlgoRex / Cerberus fire detection systems (CS11, CS10 ) from Modbus master or client devices (SCADA, BMS, PLC, HMI, TouchPanels ) Monitor & Control your network of CERBERUS fire panels remotely from your Control Center using any commercial SCADA or monitoring software with Modbus TCP driver. IBOX-MBS-CERBERUS has been designed to monitor and control Siemens Cerberus fire detection systems (equipped with BMS interface providing ISO 1745 protocol through serial port RS232), from a Modbus master or client device. Several panels connected in network can be integrated using just one IntesisBox, up to 5000 points in total. IntesisBox connects directly to the serial port RS232 of the Cerberus interface providing ISO 1745 protocol in one side, and in the other side to the Modbus network, via TCP (Ethernet) or RTU (RS232 or RS485) configurable by software. Immediate availability of the states of Cerberus elements in IntesisBox (event driven protocol). IntesisBox has a fully configurable table associating Cerberus elements with Modbus register addresses, also the value desired in Modbus to indicate any possible state (alarm, fault ) is fully configurable. Commands toward Cerberus are allowed (Reset, Test, AckAlarm ), the value to use in Modbus for each command is configurable. Date & time synchronization of Cerberus can be done by writing in specific Modbus registers enabled for this. IntesisBox Modbus Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. The user interface of LinkBoxMB allows simulating the values of the Modbus registers without the need to be physically connected to the panel, very useful while in commissioning phase.
14 Modbus Server - Siemens FC330A Ref. IBOX-MBS-FC330A Gateway for monitor and control Siemens FC330A fire detection systems from Modbus master or client devices (SCADA, BMS, PLC, HMI, TouchPanels ) Monitor & Control your network of CERBERUS fire panels remotely from your Control Center using any commercial SCADA or monitoring software with Modbus TCP driver. IBOX-MBS-FC330A has been designed to monitor Siemens FC330A fire panels from a Modbus master or client device. IntesisBox connects directly to the serial port RS232 of the FC330A panel in one side, and to the Modbus network in the other side, via TCP (Ethernet) or RTU (RS232 or RS485) configurable by software. States of Zones, Control Zones and Inputs are monitored through independent Modbus registers, each possible state is indicated by a predefined value in Modbus (0-Normal, 1- Disconnected, 2-Local Alarm UnAck ). Commands toward the FC330A panel are also allowed (Ack, Reset ). Fixed Modbus address map, the register number identifies the element (zone, input ) into the FC330A panel. Simple configuration, no point's configuration needs to be entered, just the communication parameters (IP address, baud rate ). One full panel capacity is supported. IntesisBox Modbus Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. The user interface of LinkBoxMB allows simulating the values of the Modbus registers without the need to be physically connected to the panel, very useful while in commissioning phase.
15 Modbus Server - KILSEN KSA 7xx series Ref. IBOX-MBS-KILSEN Gateway for monitor KILSEN fire detection systems from Modbus master or client devices (SCADA, BMS, PLC, HMI, TouchPanels ) Monitor your network of KILSEN KSA 7xx series fire panels remotely from your Control Center using any commercial SCADA or monitoring software with Modbus TCP driver. IBOX-MBS-KILSEN has been designed to monitor KILSEN fire panels from a Modbus master or client device. IntesisBox connects directly to the serial port RS232 of the KILSEN panel in one side, and to the Modbus network in the other side, via TCP (Ethernet) or RTU (RS232 or RS485) configurable by software. States of Zones, and Elements are monitored through independent Modbus registers, each possible state is indicated by a predefined value in Modbus (0-Normal, 1-Alarm, 2-PreAlarm, 3-Fault, 4-Disconnected). Fixed Modbus address map, the register number identifies the element or zone into the panel. Simple configuration, no point's configuration needs to be entered, just the communication parameters (IP address, baud rate ). One full panel capacity is supported. IntesisBox Modbus Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. The user interface of LinkBoxMB allows simulating the values of the Modbus registers without the need to be physically connected to the panel, very useful while in commissioning phase.
16 Modbus Server - ZITON ZP3 (ZCP2-2 protocol) Ref. IBOX-MBS-ZITON Gateway for monitor ZITON ZP3 fire panels from Modbus master or client devices (SCADA, BMS, PLC, HMI, TouchPanels ) Monitor your network of ZITON fire panels remotely from your Control Center using any commercial SCADA or monitoring software with Modbus TCP driver. IBOX-MBS-ZITON has been designed to monitor ZITON fire panels from a Modbus master or client device. IntesisBox connects directly to the serial port RS232 of the ZITON panel in one side, and to the Modbus network in the other side, via TCP (Ethernet) or RTU (RS232 or RS485) configurable by software. States of Elements are monitored through independent Modbus registers, each possible state (Normal, Fire Alarm, PreAlarm ) can be indicated in Modbus by the desired value, freely configurable. Fixed Modbus address map, the register number identifies the element into the panel. Simple configuration, no point's configuration needs to be entered, just the communication parameters (IP address, baud rate ). Elements can also be grouped allowing to monitor several elements through a single Modbus register (a kind virtual zones). One full panel capacity is supported. IntesisBox Modbus Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. The user interface of LinkBoxMB allows simulating the values of the Modbus registers without the need to be physically connected to the panel, very useful while in commissioning phase.
17 Modbus Server - ADEMCO Algorinet (BC216-x) Ref. IBOX-MBS-ALGORI Gateway for monitor ADEMCO Algorinet (BC216-x) fire detection systems from Modbus master or client devices (SCADA, BMS, PLC, HMI, TouchPanels ) Monitor & Control your network of ADEMCO Algorinet fire panels remotely from your Control Center using any commercial SCADA or monitoring software with Modbus TCP driver. IntesisBox connects directly to the serial port RS232 of the Algorinet panel and allows Modbus TCP (Ethernet) or Modbus RTU (RS232 or RS485) communication, configurable by software. IntesisBox is a server device in case of Modbus TCP communication, or a slave device in case of Modbus RTU communication. Fully configurable Modbus address map, the register address for each element into the panel can be freely assigned, offering a very powerful and flexible configuration. Integration of up to 5000 points is supported. Monitoring of the Algorinet elements (detectors, outputs ) through independent Modbus registers. The value in the Modbus register indicating the state of the panel's element is fully configurable. Commands toward the panel are also supported (reset, silence, test elements ) and the values to use from Modbus for each command are also fully configurable. IntesisBox Modbus Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. The user interface of LinkBoxMB allows simulating the values of the Modbus registers without the need to be physically connected to the panel, very useful while in commissioning phase.
18 Modbus Server - ADEMCO Galaxy (SIA Protocol) Ref. IBOX-MBS-GALAXY Gateway for monitor and control ADEMCO Galaxy (SIA protocol) security systems from Modbus master or client devices (SCADA, BMS, PLC, HMI, TouchPanels ) Monitor & Control your network of ADEMCO Galaxy security systems remotely from your Control Center using any commercial SCADA or monitoring software with Modbus TCP driver. IntesisBox connects directly to the serial port RS232 of the Galaxy panel and allows Modbus TCP (Ethernet) or Modbus RTU (RS232 or RS485) communication, configurable by software. IntesisBox is a server device in case of Modbus TCP communication, or a slave device in case of Modbus RTU communication. Fixed Modbus address map, the register number identifies the element into the panel. Simple configuration, no point's configuration needs to be entered, just the communication parameters (IP address, baud rate ). One full panel capacity is supported. Monitoring of the Galaxy elements (groups, zones, outputs ) through independent Modbus registers. The zones in use (from 1 to 512) can be selected. Commands toward the panel are also supported (reset, force set, omit zone ). IntesisBox Modbus Server series are configured using LinkBoxMB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. The user interface of LinkBoxMB allows simulating the values of the Modbus registers without the need to be physically connected to the panel, very useful while in commissioning phase.
19 BACnet/IP server KNX EIB Modbus Modbus master (client) gateways designed for integration of Modbus devices or systems into other control systems (BACnet, KNX...) Manufacturers Honeywell Delta Building Alerton KMC Siemens ABB Merten JUNG Berker Theben And many others Protocols BACnet KNX EIB Media Ethernet KNX TP-1 (EIB) Full monitoring and control IntesisBox RS232, RS485 TCP/IP Modbus TCP or RTU Device or system Heaters Chillers Heat Pumps Heating floors Air conditioners Thermostats Electricity meters PLCs...
20 KNX - Modbus RTU master Ref. IBOX-KNX-MBRTU-A / IBOX-KNX-MBRTU-B Gateway for integration of Modbus RTU slave devices (thermostats, electricity meters, chillers, heating floors, PLCs ) into KNX EIB installations. IBOX-KNX-MBRTU-A and IBOX-KNX-MBRTU-B have been designed to offer full monitoring/control of Modbus slave devices or systems from KNX EIB installations. Specially suited for integration of thermostats, electricity meters, chillers, heating floors, PLCs into KNX EIB. Connects directly to the EIB bus in one side, and in the other side it communicates to the system to integrate via Modbus RTU. Supports Modbus RTU protocol over RS232 or RS485. Bi-directional monitoring and control, register addresses, functions and data types fully configurable in the Modbus interface. IBOX-KNX-MBRTU-A supports up to 500 points, and IBOX-KNX-MBRTU-B supports up to IntesisBox KNX series are configured using LinkBoxEIB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. Demo configuration files are also supplied for LinkBoxEIB with no additional cost, making the configuration of IntesisBox for this integration extremely easy and quick, almost plug & play.
21 KNX - Modbus TCP master Ref. IBOX-KNX-MBTCP-A / IBOX-KNX-MBTCP-B Gateway for integration of Modbus TCP slave devices (thermostats, electricity meters, chillers, heating floors, heat pumps, PLCs ) into KNX EIB installations. IBOX-KNX-MBTCP-A and IBOX-KNX-MBTCP-B have been designed to offer full monitoring/control of Modbus slave devices or systems from KNX EIB installations. Specially suited for integration of thermostats, electricity meters, chillers, heating floors, heat pumps, PLCs into KNX EIB. Connects directly to the EIB bus in one side, and in the other side it communicates to the system to integrate via Modbus TCP. Supports Modbus protocol over TCP/IP. Bi-directional monitoring and control, register addresses, functions and data types fully configurable in the Modbus interface. IBOX-KNX-MBTCP-A supports up to 500 points, and IBOX-KNX-MBTCP-B supports up to 3000 points. IntesisBox KNX series are configured using LinkBoxEIB, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. Demo configuration files are also supplied for LinkBoxEIB with no additional cost, making the configuration of IntesisBox for this integration extremely easy and quick, almost plug & play.
22 BACnet/IP server - Modbus RTU master Ref. IBOX-BAC-MBRTU-A / IBOX-BAC-MBRTU-B Gateway for integration of Modbus RTU slave devices (thermostats, electricity meters, chillers, heating floors, PLCs ) into BACnet/IP control systems. IBOX-BAC-MBRTU-A and IBOX-BAC-MBRTU-B have been designed to offer full monitoring/control of Modbus slave devices or systems from BACnet/IP networks. Specially suited for integration of thermostats, electricity meters, chillers, heating floors, PLCs into BACnet/IP control systems (BMS, SCADA, PLCs ). Connects directly to the BACnet/IP network in one side, and in the other side it communicates to the system or device to integrate via Modbus RTU. Supports Modbus RTU protocol over RS232 or RS485, software configurable. IntesisBox is a Modbus RTU master device. Bi-directional monitoring and control of Modbus slave devices. Register addresses, functions and data types fully configurable in the Modbus interface. COV and Polling supported in the BACnet/IP interface. Modbus devices' points available in BACnet through present_value property of AI, AO, AV, DI, DO, DV, MI, MO, MV objects. IBOX-BAC-MBRTU-A supports up to 500 points, IBOX-KNX-MBRTU-B supports up to 3000 points, and both allow integration of up to 254 Modbus RTU slave devices. IntesisBox BACnet/IP Server series are configured using LinkBoxBacnet, a software tool for windows TM which is supplied along with the purchase of IntesisBox with no additional cost. Demo configuration files are also supplied for LinkBoxBacnet with no additional cost, making the configuration of IntesisBox for this integration extremely easy and quick, almost plug & play.
23
IntesisBox. Making Building Automation go further. KNX EIB Products
IntesisBox Making Building Automation go further KNX EIB Products October 2008 Overview of products KNX EIB gateways and interfaces designed for integration of third party systems into KNX control systems
IntesisBox ASCII Server - LON
IntesisBox ASCII Server - LON Gateway for integration of LON devices into ASCII enabled control systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi
IntesisBox. Making Building Automation go further. OPC Servers
IntesisBox Making Building Automation go further OPC Servers OPC Servers 2009 Intesis Software S.L. All rights reserved. IntesisBox is a registered trademark of Intesis Software SL.. All trademarks and
IntesisBox KNX - LON
IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,
Modbus Server SAMSUNG Air Conditioners
IntesisBox Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung Air Conditioning Systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel ) Master TCP Master
IntesisBox Modbus Server - Mitsubishi Electric G50
IntesisBox Server - Mitsubishi Electric G50 Gateway for monitor and control Mitsubishi Electric City Multi Air Conditioning systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel )
IntesisBox KNX Modbus RTU master
IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
IntesisBox KNX Modbus TCP master
IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration
IntesisBox Modbus Server Fidelio IP
IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master
ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.
IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master
IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.
IntesisBox KNX SAMSUNG Air Conditioning Gateway for integration of Samsung air conditioners into KNX control systems. Integrate Samsung Air Conditioners into KNX. KNX EIB Bus IntesisBox RS485 MIM-B13x/B04A
IntesisBox KNX LG Air Conditioning
IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit
IntesisBox KNX Mitsubishi Heavy Industries AC
IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)
KNX Panasonic Air Conditioners
IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line
EKON BMS HVAC system. Simply Smart. www.ekonhome.com. Touch Screen Controller. Going green. Wireless. Wireless Thermostat with Light Switch
Going green EKON BMS HVAC system Wireless Thermostat with Light Switch Control Fan Coil or Central AirCon Wireless Touch Screen Controller Wireless Light or Motorized Blind Wall Switch www.ekonhome.com
IntesisBox DK-RC-KNX-1
IntesisBox DK-RC-KNX-1 Interface KNX for DAIKIN Air Conditioners (SKY & VRV) AC Indoor Unit Wired Remote Control DK-RC-KNX-1 KNX / EIB bus IntesisBox DK-RC-KNX-1 allows monitoring and control, fully bi-directionally,
Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications
Page 1 / 14 Technical specifications Page 2 / 14 SUMMARY 1. GENERAL OVERVIEW 1.1 MIOS and the remote management 1.2 The MIOSBOX range 1.3 Synthesis of MIOSBOX s specificities 2. DETAILED PRESENTATION OF
PCS0100en 02.2008. Persy Control Services B.V. Netherlands
P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for
SAUTER novapro Open: B-AWS. BACnet Advanced Workstation
SAUTER novapro Open: B-AWS BACnet Advanced Workstation SAUTER novapro Open: A SCADA system that provides all needs for any type of building. Open for public buildings Secure for FDA and GAMP Flexible for
TX2123 RS485 TO ETHERNET ADAPTOR
TX2123 RS485 TO ETHERNET ADAPTOR Converts Datacomms between fibre optic Modbus TCP over Ethernet and hard-wired copper Modbus RTU over RS485 Fibre Optic MODBUS TCP/ IP Ethernet Copper MODBUS RTU RS485
LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 [email protected]
Integrations LGAC-KNX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 [email protected] www.ingeniumsl.com
ComfortPoint Open Building Management System. For consultants and specifiers. The Simply Smart way to optimize building control and performance
ComfortPoint Open Building Management System For consultants and specifiers The Simply Smart way to optimize building control and performance ComfortPoint Open BMS. Simply Smart. The Honeywell ComfortPoint
NXL Series Inverters. HVAC Inverters made simple
NXL Series Inverters HVAC Inverters made simple Honeywell s Voice Of the Customer process unveils a range of requirements expressed by specifiers and installers, that are ideally covered by the NXL inverter
NC-12 Modbus Application
NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1
User Manual Revision 2.003 English
Document code: MN67120_ENG Revision 2.003 Page 1 of 15 User Manual Revision 2.003 English RS232 / RS485 / Ethernet - Converter (Order Code: HD67120) for Website information: www.adfweb.com?product=hd67120
sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved
Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section
DIANEMO HOME AUTOMATION & CONTROL SERVER
C O N V E R G E N T H O M E T E C H N O L O G I E S L I M I T E D DIANEMO HOME AUTOMATION & CONTROL SERVER The Dianemo Home Automation Server is designed to bring together all your digital services, media
User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M)
Document code: MN67038-2_ENG Revision 1.400 Page 1 of 25 User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) for
Modbus and ION Technology
70072-0104-14 TECHNICAL 06/2009 Modbus and ION Technology Modicon Modbus is a communications protocol widely used in process control industries such as manufacturing. PowerLogic ION meters are compatible
Electronic Control Devices The European Product Catalogue 2007
FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,
User Manual Revision 1.002 English
Document code: MN67513_ENG Revision 1.002 Page 1 of 15 User Manual Revision 1.002 English Gateway / Adapter CAN to Ethernet (Order Code: HD67513 HD67513M) HD67513 for Website HD67513 information: www.adfweb.com?product=hd67513
SIMATIC S7-1200. It s the Interplay that makes the difference. Siemens AG 2010. All Rights Reserved.
SIMATIC S7-1200 It s the Interplay that makes the difference SIMATIC S7-1200 Controller SIMATIC S7-1200 CPUs CPU 1211C 3 configurations per CPU Dimensions W x H x D (mm) CPU 1212C CPU 1214C DC/DC/DC, AC/DC/RLY,
Building Management System Gateway. Installation and Commissioning Manual Man-1181 Issue 07 June 2013
Building Management System Gateway Installation and Commissioning Manual Man-1181 Issue 07 June 2013 Index Page 1. Overview... 3 2. Power Requirements... 4 2.1 OpenConnect Gateway Power Requirements...
Modbus and ION Technology
Modbus and ION Technology Modicon Modbus is a communications protocol widely used in process control industries such as manufacturing. ACCESS meters are compatible with Modbus networks as both slaves and
Company Profile. Building Automation / Management system: Capabilities: Supply,Testing and Commissioning
Company Profile KVN Technical services LLC is based in Dubai (UAE). The company's principal areas of business interests include Building Management System (BMS), Technical project management, Supply installation
User Manual Revision 2.001 English
Document code: MN67020_ENG Revision 2.001 Page 1 of 11 User Manual Revision 2.001 English M-Bus Master / RS232 - Converter (Order Codes: HD67020-B2-3, HD67020-B2-10) for Website information: www.adfweb.com?product=hd67020
GE Security. FHSD Monitor / Web Server user manual
GE Security FHSD Monitor / Web Server user manual version 1-0 / november 2004 http://www.geindustrial.com/ge-interlogix/emea 2004 GE Interlogix B.V.. All rights reserved. GE Interlogix B.V. grants the
BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter
BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6
The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT
The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT Presented by: Michael Kuhlmann President Residential Control Systems Inc The Basics Thermostat Functions Measure Room
How to use Citect (SCADA) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021)
with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021) Alex Chen, Senior Engineer, Moxa Technical Support Dept. In this Technical Note, we cover the following topics: 1. How to export
Tim Sisson - Trane HVAC OVERVIEW
Tim Sisson - Trane HVAC OVERVIEW HVAC Systems System Types Acoustics Controls Modernization more than one Down to the Studs Opportunity for new System Type Renovation Possible opportunity for new System
Medical Vacuum Systems-PXMI
Medical Vacuum Systems-PXMI Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing
How to use KEPServerEX OPC Server (Kepware) with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021)
with iologik 4000 (Modbus TCP/IP NA-4010 and Modbus Serial NA-4020/NA-4021) Alex Chen, Senior Engineer, Moxa Technical Support Dept. In this Technical Note, we cover the following topics: 1. How to export
Premium Server Client Software
Premium Server Client Software Server / Client SMSPro & GSMS TH series Get the tools on hand Premium Server is designed to cover most of the applications in the market. It gives a hassle free management
Integrated Building Management and Security System. Building Automation & Security. www.coba-group.com
Integrated Building Management and Security System Building Automation & Security www.coba-group.com INTEGRATED BUILDING MANAGEMENT AND SECURITY SYSTEM INDEX 1 GENERAL... 3 1.1 SYSTEM INTEGRATION... 3
EtherNet/IP Scanner Configuration for the Moxa MGate 5105-MB-EIP
the Moxa MGate 5105-MB-EIP Contents Moxa Technical Support Team [email protected] 1. Introduction... 2 2. Applicable Products... 2 3. System Requirements... 2 4. System Overview... 2 5. Configuring a Moxa
EZ-View Network Communications Guide www.cszindustrial.com
Network Communications Guide EzView Network Communications Guide RevB July 2013 (V2.2) Supersedes: RevA (May 2011) Cincinnati Sub-Zero Products, LLC 513-772-8810 12011 Mosteller Road Cincinnati, Ohio 45241
User Manual Revision 1.002 English
Document code: MN67075_ENG Revision 1.002 Page 1 of 15 User Manual Revision 1.002 English Modbus RTU / Modbus ASCII - Converter (Order Code: HD67075-A1) for Website information: www.adfweb.com?product=hd67075
Configuring Allen-Brandly ControlLogix PLC with Moxa MGate 5105-MB-EIP. 1 Application Description... 3. 1.1 Objective... 3 1.2 Goals...
Moxa MGate 5105-MB-EIP Contents Moxa Technical Support Team [email protected] 1 Application Description... 3 1.1 Objective... 3 1.2 Goals... 3 2 System Topology... 3 3 Hardware and Software Requirements...
INDUSTRIAL GATEWAYS VPN ROUTERS SERIAL DEVICE SERVERS
INDUSTRIAL GATEWAYS VPN S SERIAL DEVICE SERVERS 100% Made & Designed in Italy ETHERNET VIRTUAL COM TUNNELLING TCP-IP REDUNDANCY REMOTE CONTROL MODEM REMOTE ASSISTANCE WEB HMI/ SERVER SCADA VPN 3G+ SENECA
Process Control and Automation using Modbus Protocol
Process Control and Automation using Modbus Protocol Modbus is the fundamental network protocol used in most industrial applications today. It is universal, open and an easy to use protocol. Modbus has
Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen
Equipment, facilities, and service networks for data collection/logging, data transfer via e-mail/website, and system streamlining can be established without special knowledge. Energy saving system in
PU-USBX. USB over Ethernet Extender OPERATION MANUAL
PU-USBX USB over Ethernet Extender OPERATION MANUAL Safety Precautions Please read all instructions before attempting to unpack or install or operate this equipment, and before connecting the power supply.
EDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
Repeaters and Mimics Data Sheet
Repeaters and Mimics Data Sheet IDR series repeaters and mimics allow vital information from a Notifier fire system to be communicated to points around a building remote from the fire alarm control panel.
Z-TWS4. Multifunction Straton / LINUX Controller. www.seneca.it
Z-TWS Multifunction Straton / LINUX Controller OPC Linux High-level Control System suitable for: Energy Management (IEC 0870--0, IEC 0870--0, IEC 80) Plant automation (Straton - Soft PLC IEC -) CPU Linux-based
Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected
Niagara Security Overview Niagara Security by Tridium, is an open, web-based security management solution that allows you to manage and monitor your facility anytime, anywhere. Built on Tridium s Niagara
Digital Marquee Series
THE SIMPLE MARQUEE SOFTWARE EMBEDDED WEB SERVER Digital Marquee Series Part # DM-0213-T Part # DM-0113-T Part # DM-0220-T Part # DM-0420-T PRODUCT DESCRIPTION The Digital Marquee Series is a simple and
M-series Virtual I/O Module 2
DeltaV Distributed Control System Product Data Sheet M-series Virtual I/O Module 2 Non-intrusive DeltaV I/O simulation Powerful integration solution Easy to use Modular, flexible packaging The M-series
DSX-Soft I/O Integration Software
DSX Access Systems, Inc. DSX-Soft I/O Integration Software DSX now has the ability to integrate with various different external devices through serial data streams. This integration allows other systems
Client-Server SCADA Technology
Client-Server SCADA Technology A FULL WEB BROWSER-BASED SUITE BRIDGING THE OPERATION & INFORMATION GAP WITH WEB BROWSER DASHBOARDS FOR: v MANAGEMENT DECISION MAKERS v PRODUCTION/ OPERATIONS v MOBILE WORKFORCES
Electronic Control Devices The European Product Catalogue 2007
FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically
Square D Model 6 Motor Control Centers
Square D Model 6 Motor Control Centers with Ethernet Communications What is industrial Ethernet? Over the past few years the use of Ethernet communications has spread into every corner of the business
System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution
System integration oriented data center planning In terms of ATEN's eco Sensors DCIM solution 1. Introduction The reliability of an enterprise data center servicing either external or internal clients
User Manual Revision 2.000 English
Document code: MN67031_ENG Revision 2.000 Page 1 of 29 User Manual Revision 2.000 English M-Bus Analyzer / Scanner / Sniffer (Order Code: HD67031-B2-xxx) for Website information: www.adfweb.com?product=hd67031
OPTICAL FIBER repeaters/ isolators
OPTICAL FIBER repeaters/ isolators FUNCTINALITY AND RELIABILITY' Optical Fiber converters give the possibilità to extend on Optical Fiber (also at the same time) every type of network/bus (LAN/Ethernet,
Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling
Electronics Ltd Presenting Power, Intelligence... with a sense of feeling By Appointment to Her Majesty The Queen Supplier of Fire Detection Equipment Kentec Electronics Ltd. Dartford Plug in slots K772
M2M/IoT Solutions. www.contec.com
M2M/IoT Solutions www.contec.com M2M/IoT Solutions TM Hardware Highly Reliable M2M Controllers for Various Solutions M2M Controllers Compact design available on DIN rails Low-power design using a CPU tailored
White Paper. Technical Capabilities of the DF1 Half-Duplex Protocol
White Paper Technical Capabilities of the DF1 Half-Duplex Protocol Introduction DF1 Protocol To meet the challenges of today s global marketplace communication and network, systems must offer customers
Intelligent Integrated Systems
Intelligent Integrated Systems Lonix IBMS Lonix Ltd Lonix System Your Trusted Solution Automation - BMS LONIX System Access Control Room/Unit Controls Integration Software Video Monitoring Core Platform
1 Application Description... 3. 1.1 Objective... 3 1.2 Goals... 3
Contents Moxa Technical Support Team [email protected] 1 Application Description... 3 1.1 Objective... 3 1.2 Goals... 3 2 System Topology... 3 3 Hardware and Software Requirements... 4 4 Configuration...
Application/Connection Examples
This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.
IntesisBox DK-RC-ENO-1iC. EnOcean Interface for DAIKIN Air Conditioners Compatible with SKY and VRV lines
IntesisBox DK-RC-ENO-1i DK-RC-ENO-1iC EnOcean Interface for DAIKIN Air Conditioners Compatible with SKY and VRV lines User's Manual r1 eng Issue Date: 02/2012 Intesis Software S.L. All Rights Reserved.
User manual Compact Web PLC WP240 series IEC-line
User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys
Supporting ANY PRODUCT employing
Supporting ANY PRODUCT employing -BackNet -LonWorks -ModBus - XML -SNMP -OPC WEB controllers (JACE-Java Application Control Engine) - Provides server and internet power at the building level - Open & legacy
CoolMaster User Manual
CoolMaster Universal Interface Adapter for VRV, VRF Air Conditioning Systems CoolMaster 1000D CoolMaster 2000S CoolMaster 3000T CoolMaster 4000M CoolMaster 6000L CoolMaster 7000F CoolMaster 8000MH CoolMaster
Using Industrial IoT (IIoT)Technology
DeviceLynk is an Industrial Internet of Things application that delivers Actionable Information via hierarchical dashboards that enables users to quickly determine the appropriate action to take. When
Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male
IntesisBox ME-AC-ENO-1C
IntesisBox ME-AC-ENO-1 ME-AC-ENO-1C v.1.0.9 v.1.0.9 EnOcean Interface for Mitsubishi Electric air conditioners. Compatible with all models of Domestic and Mr. Slim lines of air conditioners commercialised
Application Note: Connecting to a 2500 Series Processor using PLC Workshop
Application Note: Connecting to a 2500 Series Processor using PLC Workshop This application note will describe a step by step process for the three ways to connect to a 2500-CXXX with PLC Workshop. The
F453. TiF453. User guide 10/11-01 PC
F453 TiF453 User guide 10/11-01 PC 2 TiF453 User guide Contents 1. Hardware and Software requirements 4 2. Installation 4 1.1 Minimum Hardware requirements 4 1.2 Minimum Software requirements 4 3. Fundamental
User Manual Revision 2.101 English
Document code: MN67011_ENG Revision 2.101 Page 1 of 18 User Manual Revision 2.101 English CAN / Modbus Master - Converter (Order Code: HD67011) for Website information: www.adfweb.com?product=hd67011 HD67011
SolarEdge. RS485 Expansion Kit Installation Guide. Version 1.0
SolarEdge RS485 Expansion Kit Installation Guide Version 1.0 Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in
Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter
EA7-T8C EA7-T10C EA7-T12C EA7-T15C
The new Generation of Touch Panels with ambitious image presentation and integrated operating function With the C-more series, featuring STN and TFT touch screens, AutomationDirect now provides the best
BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP
s 9 270 Desigo PX BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP PXG3.L PXG3.M Routing between BACnet/IP, BACnet/LonTalk (PXG3.L only), and BACnet MS/TP Supports BACnet/IPv4 and BACnet/IPv6 ANSI/ASHRAE
Application Sheet Fan coil unit with staged fan, heating/cooling coil (2 pipe) on analog output
Heating with LHW and cooling with CHW changeover Modulating control of heating and cooling valve (2 pipe) on analog Automatic or manual 3-speed fan control Room temperature and fan speed operation via
R001. Room Control Unit TG650. Summary. Control functions. Orders. Planning. Installation
R001 Room Control Unit TG650 Summary TG650 Microprocessor Room Control Unit is designed to manage and control hotel room services. The Room Unit automatically manages the electric system validation on
User Manual Revision 1.012 English
Document code: MN67595_ENG Revision 1.012 Pagina 1 di 27 User Manual Revision 1.012 English EtherNet/IP / CAN - Converter (Order Code: HD67595-A1) for Website information: www.adfweb.com?product=hd67595
Straton and Zenon for Advantech ADAM-5550. Copalp integrates the straton runtime into the ADAM-5550 device from Advantech
Straton and Zenon for Advantech ADAM-5550 Copalp integrates the straton runtime into the ADAM-5550 device from Advantech Project Introduction: Programmable Application Controllers (PAC) are powerful and
Communication in building automation
Communication in building automation Answers for infrastructure and cities. BACnet www.big-eu.org Introduction The communication protocol BACnet was specially developed for the requirements of buildings.
Temperature & Humidity SMS Alert Controller
Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal
PRODUCT LIST Facility DDC Access WebXL DDC
PRODUCT LIST Facility DDC Access WebXL DDC Effective from 01/10/2014 Sphere Systems Pty Ltd Unit 6 / 9 Mirra Crt Bundoora Victoria Australia 3083 ABN 98 006 579 004 Phone +61 3 9470 8844 Fax +61 3 9470
VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0
VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0 1. Installation Requirements 1.1. PC Pentium III processor or higher. Minimum RAM memory: 128 Mbytes Operating system: Windows XP
Engineering and service software For KNX and LPB plants
5 649 Engineering and service software For KNX and LPB plants As of V9.00 ACS790 The engineering and service software ACS790 is for KNX and LPB plants equipped with the appropriate bus devices. The software
User Manual Revision 2.002 English
Document code: MN67513_ENG Revision 2.002 Page 1 of 17 User Manual Revision 2.002 English CAN / Ethernet - Converter (Order Code: HD67513-A1 HD67513-B2) for Website information: HD67513 www.adfweb.com?product=hd67513
Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry.
Plant automation and telecontrol in one system SIMATIC TeleControl SIMATIC Answers for industry. SIMATIC TeleControl The intelligent solution for installations with local and widely distributed automation
User Manual Revision 2.002 English
Document code: MN67221F_ENG Revision 2.002 Page 1 of 19 User Manual Revision 2.002 English CAN / Optic Fiber Repeater Extender bus line (With filter data configurable) (Order Code: HD67221F - HD67221FS)
Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.
Data Bulletin 1210DB0002R3/05 03/2005 LaVergne, TN, USA Communications Wiring for POWERLINK G3 Systems Class 1210 Retain for future use. ABOUT THIS BULLETIN This data bulletin describes the proper wiring
