IntesisBox Modbus Server - Mitsubishi Electric G50

Size: px
Start display at page:

Download "IntesisBox Modbus Server - Mitsubishi Electric G50"

Transcription

1 IntesisBox Server - Mitsubishi Electric G50 Gateway for monitor and control Mitsubishi Electric City Multi Air Conditioning systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel ) Master TCP LinkBoxMB Configuration Software Master RTU RTU RS232/RS485 RS232 IntesisBox Only needed for configuration Ethernet TCP LAN / WAN XML G50 G50 Mitsubishi Electric City Multi Mitsubishi Electric City Multi This integration requires the Mitsubishi Electric City Multi AC system be equipped with the Mitsubishi Electric G-50A, GB-50A o AG-150A gateway This gateway from Mitsubishi Electric offers the signals of the City Multi AC system through XML protocol Every G50 (G-50A, GB-50A o AG-150A) allows access to the signals of up to 50 City Multi internal units and 50 groups, no matter the number of external units installed In the G50, the group is the control unit, every group can have from 1 to 16 associated internal units This integration supervises and control groups, not internal units, although if only one internal unit is associated to every group then you can supervise and control internal units individually This G50 gateway is supplied by Mitsubishi Electric Contact your nearest Mitsubishi Electric distributor for details IntesisBox can talk to up to 2 Mitsubishi Electric G50s using XML protocol, and offers the signals of all these City Multi groups through its slave interface, each signal in a predefined fixed address The AG-150A can be used with Expansions Cards as explained in the section IntesisBox capacity The interface of IntesisBox can be freely configured as RTU RS232, RTU RS485 or TCP The commissioning of IntesisBox is almost plug & play, only IP parameters of the box and of G50s have to be configured using LinkBoxMB, a friendly software configuration tool for Windows TM supplied along with IntesisBox with no additional cost TRADEMARKS: Todas las marcas y nombres utilizados en este documento se reconocen como marcas registradas de sus respectivos propietarios 1 / 11

2 1 IntesisBox capacity Element Max Notes Num of G50 2 Number of independent G50 interfaces 2 x G-50A / GB-50A 2 x AG150 (without Expansion Controllers) 1 x AG150 (with 2 Expansion Controllers) Number of City Multi groups: (Number of G50s X 50) 100 Maximum number of groups Number of variables per group 19 addresses Number of variables per G addresses Maximum number of variables 1902 addresses There are 2 different models of IntesisBox server - Mitsubishi Electric G50 with different capacity every one of them The table above shows the capacity for the top model (with maximum capacity) The 2 different models allow integrating respectively: 1 or 2 G50s And their order codes are: ME-AC-MBS-50 Model supporting up to 1 G50 and 50 City Multi groups ME-AC-MBS-100 Model supporting up to 2 G50s and 100 City Multi groups! NOTE: Please, remember that Mitsubishi Electric AG-150A requires a software license, PC-Monitoring license (SW-Mon), that has to be purchased together with the AG-150A gateway TRADEMARKS: Todas las marcas y nombres utilizados en este documento se reconocen como marcas registradas de sus respectivos propietarios 2 / 11

3 2 Sample applications Integration of Mitsubishi Electric City Multi Air Conditioning systems equipped with the interface G50 into control systems Master TCP Master RTU RTU RS232/RS485 IntesisBox Ethernet TCP LAN / WAN XML G50 G50 Mitsubishi Electric City Multi Mitsubishi Electric City Multi Control system with master interface: BMS SCADA PLC DDC Home Automation AMX, Crestron Typical Mitsubishi Electric Air Conditioning systems equipped with G50 interface: City Multi model G-50A (version of G50 with display and keypad), GB-50A (version of G50 with blind cover), and AG-150A (new version of G50 with touch-display) are all supported, no difference from IntesisBox's point of view 50 City Multi indoor units or 50 groups per G50 Every group can have from 1 to 16 associated indoor units MODBUS Full supervision and control System supervising / controlling System under supervision / control TRADEMARKS: Todas las marcas y nombres utilizados en este documento se reconocen como marcas registradas de sus respectivos propietarios 3 / 11

4 3 Typical applications Integration of Mitsubishi Electric Air Conditioning into systems For this application, Mitsubishi Air Conditioning system must be equipped with G-50A, GB-50A or AG-150A Gateway For more information about these devices contact Mitsubishi Electric Indoor units Outdoor unit Bus M-Net G-50A, GB-50A or AG-150A (with XML option) Ethernet (crossed cable) network IntesisBox Master TCP / RTU ME-AC-MBS-50 TRADEMARKS: Todas las marcas y nombres utilizados en este documento se reconocen como marcas registradas de sus respectivos propietarios 4 / 11

5 4 interface General Max Number of Up to two G50s can be supported Mitsubishi ElecG50s Virtual signals One communication error virtual signal per every G50 device defined One communication error virtual signal per every group into the G50 device One virtual signal per every group into the G50 device to enable/disable this group in the polling process All these virtual signals can be read/written from interface Device type Slave modes TCP, RTU RS232 or RS485 supported TCP configuration parameters RTU configuration parameters Points Configuration function codes supported IP address Subnet mask Default gateway address TCP port RS232/RS485 Baud rate Parity Slave number No point configuration needs to be done, all the Mitsubishi Electric G50 signals are automatically associated to predefined fixed Addresses Read functions: 3- Read holding registers 4- Read input registers Write functions: 6- Write single register 16- Write multiple registers If poll records are used to read/write multiple records, the range of addresses requested must contain valid addresses, if not the corresponding error code will be responded data coding All the point's values are coded in 2 bytes registers (even if their possible values are 0 and 1) and expressed in MSBLSB TRADEMARKS: Todas las marcas y nombres utilizados en este documento se reconocen como marcas registradas de sus respectivos propietarios 5 / 11

6 41 Extract of the predefined address table Address G50 Group Property G50 Group Property Address Error Com G Error Com G Drive Drive Mode Mode SetTemp SetTemp AirDirection AirDirection FanSpeed FanSpeed RemoCon RemoCon DriveItem DriveItem ModeItem ModeItem SetTempItem SetTempItem FilterItem FilterItem Ventilation Ventilation FilterSign FilterSign ErrorSign ErrorSign InletTemp InletTemp FilterSignReset FilterSignReset ErrorSignReset ErrorSignReset Error Com Group Error Com Group Polling Active Polling Active G50 Group Property G50 Group Property Address Address Drive Drive Mode Mode SetTemp SetTemp AirDirection AirDirection FanSpeed FanSpeed RemoCon RemoCon DriveItem DriveItem ModeItem ModeItem SetTempItem SetTempItem FilterItem FilterItem Ventilation Ventilation FilterSign FilterSign ErrorSign ErrorSign InletTemp InletTemp FilterSignReset FilterSignReset ErrorSignReset ErrorSignReset Error Com Group Error Com Group Polling Active Polling Active There are also a series of signals that indicate an Alarm Code in any of the devices present in the M-Net Mitsubishi network To obtain the address, you must apply following formula: ADRESS MODBUS = ( (NumbG50x1000)) + M-Net Add where M-Net Add is 0 for the G50 device, 1 to 50 for Indoor Units, 51 to 100 for Outdoor Unit, 101 to 200 for Remote Controllers and 200 to 250 for System Controllers For more information contact Mitsubishi Electric TRADEMARKS: Todas las marcas y nombres utilizados en este documento se reconocen como marcas registradas de sus respectivos propietarios 6 / 11

7 5 Mitsubishi Electric G50 interface Mitsubishi Electric G50 interface Device type Configuration Parameters Client Polling interval (1600 seconds) Per every G50 defined: Descriptive name IP address TCP port TRADEMARKS: Todas las marcas y nombres utilizados en este documento se reconocen como marcas registradas de sus respectivos propietarios 7 / 11

8 51 Signals available per every Mitsubishi Electric City Multi AC indoor unit or group of indoor units Property Drive Mode 1 SetTemp 1 AirDirection FanSpeed RemoCon DriveItem ModeItem SetTempItem FilterItem Ventilation FilterSign ErrorSign InletTemp G50 Communication Error Group Communication Error Polling Active Alarm Code Description / Status Start/Stop Read/Write: ON, OFF AC Mode Read/Write: COOL, DRY, FUN, HEAT, AUTO, HEAT RECOVERY, LC_AUTO, BYPASS Read: AUTO HEAT, AUTO COOL Temperature Set Point (only integer numbers allowed) Read/Write: For COOL or DRY mode:1930 ºC, for HEAT mode: 1728 ºC, for AUTO mode:1928 ºC) Air output direction Read/Write: HORIZONTAL, MID1, MID2, VERTICAL, SWING AC fan speed or LOSSNAY Read/Write: HIGH, MIDH, MIDL, LOW Prohibition for General control from the local panel Read/Write: PROHIBIT, PERMIT Prohibition for ON/OFF control from the local panel Read/Write: CHK_ON, CHK_OFF Prohibition for Mode control from the local panel Read/Write: CHK_ON, CHK_OFF Prohibition for Set Point control from the local panel Read/Write: CHK_ON, CHK_OFF Prohibition for Filter Reset control from the local panel Read/Write: CHK_ON, CHK_OFF Operational status for LOSSNAY or OA Read/Write: HIGH, LOW, OFF Status for Filter Dirty Read: ON, OFF Write: RESET Error status Read: ON, OFF Write: RESET Ambient Temperature Read: 00 to 999 Communication error with G50 Virtual signal generated by IntesisBox to indicate the status of the communication with the G50 Group communication error Virtual signal generated by IntesisBox to indicate that the group is not configured into the G50 Polling active Virtual signal to indicate or set if the Group is active or not active during the polling process Group Alarm Code This signal provides a value Each value has an associated alarm that has occurred in the group (0 means no alarm) 1 PWFY units have a different mode and settemp map explained in the signals column in LinkBoxEIB (section 34 in the User Manual) TRADEMARKS: Todas las marcas y nombres utilizados en este documento se reconocen como marcas registradas de sus respectivos propietarios 8 / 11

9 6 Configuration tool LinkBoxMB Visual engineering tool, easy of use, for gateway s configuration and supervision compatible with Microsoft Windows operating systems, supplied with the gateway free of charge Multi-window tool allowing to supervise simultaneously the communication activity with both protocols (systems), real time values for all the signals allowing to modify any value (very useful for test purposes), console window showing debug and working status messages, and configuration windows to configure all the gateway s parameters and signals Signals configuration in plain text files (tab separated) for easy and quick configuration using Microsoft Excel (very useful in projects with a lot of points) Allows configuring the gateway s parameters and signals while in off-line (not connected to the gateway) Connection to the gateway for download the configuration and supervision by using serial COM port of the PC (serial cable supplied with the gateway) Allows configuring all the external protocols available for IntesisBox Server series Upgrades for this software tool available free of charge whenever a new protocol is added to the IntesisBox Server series Multi-project tool allowing having in the engineer s PC the configuration for all the sites with different IntesisBox Server series gateways Multi-language tool, all the language-dependent strings are in a plain text file (tab separated) for easy modification or addition of new languages A list of system commands is available to send to the gateway for debugging and adjust purposes (Reset, Date/time consultation/adjust, Firmware version request ) 7 TRADEMARKS: Todas las marcas y nombres utilizados en este documento se reconocen como marcas registradas de sus respectivos propietarios 9 / 11

10 Mechanical & Electrical characteristics Envelope Plastic type PC (UL 94 V-0) Size: 107mm x 105mm x 58mm Color Grey RAL 7035 Power 9 to 30VDC +/-10% 14W 24VAC +/-10% 14VA Power connector is a 2 pole plug-in screw terminal bloc Mounting options Wall DIN rail EN60715 TH35 RTU ports 1 x Serial RS232 (DB9 male DTE) 1 x Serial RS485 (Plug-in screw terminal block 2 poles) TCP & 1 x Ethernet 10BT RJ45 connector Mitsubishi ElecG50 port LED indicators 1 x Power 2 x Ethernet port link and activity (LNK, ACT) 2 x RTU port activity (Tx, Rx) Console port RS232 DB9 female connector (DCE) Configuration Via console port 1 Firmware Allows upgrades via console port Operational 0 C to +70 C temperature range Operational humidity 5% to 95%, non condensing range Protection IP20 (IEC60529) RoHS conformity Compliant with RoHS directive (2002/95/CE) Certifications CE 1 Along with the device it is also supplied a standard DB9 male - DB9 female 18 m cable for configuring and monitoring the device using a PC via serial COM port The configuration software, compatible with MS Windows operating systems, is also supplied TRADEMARKS: Todas las marcas y nombres utilizados en este documento se reconocen como marcas registradas de sus respectivos propietarios 10 / 11

11 8 Dimensions Power + Ethernet port 58 mm RTU RS232/485 Console port 107 mm 105 mm Recommended available space for its installation into a cabinet (wall or DIN rail mounting), with space enough for external connections: 100 mm 115 mm 130 mm TRADEMARKS: Todas las marcas y nombres utilizados en este documento se reconocen como marcas registradas de sus respectivos propietarios 11 / 11

Modbus Server SAMSUNG Air Conditioners

Modbus Server SAMSUNG Air Conditioners IntesisBox Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung Air Conditioning Systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel ) Master TCP Master

More information

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server SAMSUNG Air Conditioners IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,

More information

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. IntesisBox ModBus Server - KNX Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems. Integrate KNX based lighting control into your SCADA, BMS, PLC "talking" Modbus. Master

More information

IntesisBox KNX LG Air Conditioning

IntesisBox KNX LG Air Conditioning IntesisBox KNX LG Air Conditioning Gateway for integration of LG Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB) bus. Direct connection to LG outdoor unit

More information

IntesisBox Modbus Server Fidelio IP

IntesisBox Modbus Server Fidelio IP IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master

More information

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485. IntesisBox KNX SAMSUNG Air Conditioning Gateway for integration of Samsung air conditioners into KNX control systems. Integrate Samsung Air Conditioners into KNX. KNX EIB Bus IntesisBox RS485 MIM-B13x/B04A

More information

KNX Panasonic Air Conditioners

KNX Panasonic Air Conditioners IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line

More information

IntesisBox KNX Modbus RTU master

IntesisBox KNX Modbus RTU master IntesisBox KNX RTU master Gateway for integration of RTU devices into KNX control systems. Integrate RTU devices (Chillers, Roof Tops, electricity meters, heating floors, heat pumps, PLCs ) into KNX control

More information

IntesisBox KNX Modbus TCP master

IntesisBox KNX Modbus TCP master IntesisBox KNX TCP master Gateway for integration of TCP slave devices into KNX control systems. Integrate any TCP slave device into KNX. KNX TCP slave EIB Bus IntesisBox Ethernet slave LinkBoxEIB Configuration

More information

IntesisBox KNX - LON

IntesisBox KNX - LON IntesisBox KNX - Gateway for integration of devices into KNX systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi Heavy Industries, Toshiba, Fujitsu,

More information

IntesisBox ASCII Server - LON

IntesisBox ASCII Server - LON IntesisBox ASCII Server - LON Gateway for integration of LON devices into ASCII enabled control systems. Integrate Air Conditioning from the main manufacturers (DAIKIN, Mitsubishi Electric, Mitsubishi

More information

IntesisBox KNX Mitsubishi Heavy Industries AC

IntesisBox KNX Mitsubishi Heavy Industries AC IntesisBox KNX Mitsubishi Heavy Industries AC Gateway for integration of Mitsubishi Heavy Indsutries (MHI) Air Conditioners with KNX control systems. 1. Main Features Direct connection to KNX TP-1 (EIB)

More information

IntesisBox. Making Building Automation go further. KNX EIB Products

IntesisBox. Making Building Automation go further. KNX EIB Products IntesisBox Making Building Automation go further KNX EIB Products October 2008 Overview of products KNX EIB gateways and interfaces designed for integration of third party systems into KNX control systems

More information

Central Controller G-50A/GB-50A Web Browser Operation Manual (For System Maintenance Engineer)

Central Controller G-50A/GB-50A Web Browser Operation Manual (For System Maintenance Engineer) Mitsubishi Electric Building Air-conditioner Control System Central Controller G-50A/GB-50A Web Browser Operation Manual (For System Maintenance Engineer) Contents 1 Introduction...1 1-1 Conventions Used

More information

1 Serial RS232 to Ethernet Adapter Installation Guide

1 Serial RS232 to Ethernet Adapter Installation Guide Installation Guide 10/100 Mbps LED (amber color ) Link/Activity LED (green color ) 1. Introduction Thank you for purchasing this 1-port RS232 to Ethernet Adapter (hereinafter referred to as Adapter ).

More information

User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M)

User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) Document code: MN67038-2_ENG Revision 1.400 Page 1 of 25 User Manual Revision 1.400 English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD67038-2 HD67038-2-M HD67038-25 HD67038-25-M) for

More information

User manual Compact Web PLC WP240 series IEC-line

User manual Compact Web PLC WP240 series IEC-line User manual Compact Web PLC WP240 series IEC-line update: 09-01-2014 IEC-line by OVERDIGIT overdigit.com 1. General description The WP240 device is a PLC, programmable in IEC61131-3 language using CoDeSys

More information

Energy Communication Unit (ECU)

Energy Communication Unit (ECU) Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.8) ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2 2.0 Installation...

More information

IntesisBox. Making Building Automation go further. Modbus Products

IntesisBox. Making Building Automation go further. Modbus Products IntesisBox Making Building Automation go further Modbus Products October 2008 Overview of products Modbus Server (slave) gateways and interfaces designed for integration of third party systems into Modbus

More information

Waveguide Access Point WGA631. Product Guide

Waveguide Access Point WGA631. Product Guide Waveguide Access Point Product Guide Waveguide Access Point Contents 1. Description............................ 3 2. Application............................ 3 3. Technical data... 4 4. Physical interfaces......................

More information

Temperature & Humidity SMS Alert Controller

Temperature & Humidity SMS Alert Controller Temperature & Humidity Alert Controller METERS 3 simple steps starting the unit: Insert the SIM card Plug in the sensors connectors Connect the AC power cord. Specifications: AC 90~260V Auto Select Internal

More information

Loop-IP6702 TDMoEthernet

Loop-IP6702 TDMoEthernet Loop-IP6702 TDMoEthernet Description: Loop-IP-6702 device allows operator to transport 1 or 2 E1/T1* with timing and Ethernet traffic over IP network. This allows cost effective migration to IP network

More information

EDI Distributor Control Interface Wiring and Setup Instructions

EDI Distributor Control Interface Wiring and Setup Instructions Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls

More information

One Port Serial Server Users Manual Model ESP901, ESP901E

One Port Serial Server Users Manual Model ESP901, ESP901E One Port Serial Server Users Manual Model ESP901, ESP901E Documentation Number: ESP901-2303 International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road -- P.O. Box 1040 -- Ottawa, IL 61350

More information

Users manual. TCW181B-CM_R1 Page 1

Users manual. TCW181B-CM_R1 Page 1 Ethernet controller TCW181B-CM Users manual 1. Short description TCW181B-CM is 8-channel Ethernet relay board, which is designed to work in IP-based networks and managed by WEB interface or SNMP programs.

More information

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter ICS-2 S15 Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Cost Effective Solution for RS-232 / RS-422 / RS-485 to Industrial Ethernet Application PLANET ICS-210x series Smart Media Converter

More information

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410 The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a

More information

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 tecnico@ingeniumsl.com

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34) 985 113 339 tecnico@ingeniumsl.com Integrations LGAC-KNX V1.0 PROGRAMMING MANUAL Parque Tecnológico de Asturias, Parcela 50, 33428 Llanera Asturias - Spain Tel (+34) 985 118 859 Fax (+34) 984 283 560 ingeniumsl@ingeniumsl.com www.ingeniumsl.com

More information

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature

More information

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type code Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps Male

More information

MODBUS TCP to RTU/ASCII Gateway. User s Manual

MODBUS TCP to RTU/ASCII Gateway. User s Manual MODBUS TCP to RTU/ASCII Gateway User s Manual 1 INTRODUCTION... 1 1.1 FEATURES... 2 1.2 PRODUCT SPECIFICATIONS... 3 1.3 DEFAULT SETTINGS... 4 2 MAKING THE HARDWARE CONNECTIONS... 5 2.1 POWER CONNECTION...

More information

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-NMS Rev. X1 E-Mail: salessupport@olsontech.com www.olsontech.com

More information

PCS0100en 02.2008. Persy Control Services B.V. Netherlands

PCS0100en 02.2008. Persy Control Services B.V. Netherlands P-Bus Gateway PBGW2.128 Universal gateway between the P-bus protocol and open standard protocols. The variety of available electrical interfaces on the gateway offers a wide range of possibilities for

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX14 Field Controller (1/4) FX14 Field Controller The FX14 is an equipment field controller in the Facility Explorer range of products. The controller is designed specifically for commercial Heating, Ventilating,

More information

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL w w w. c d v g r o u p. c o m CA-ETHR-A: TCP/IP Module Installation Manual Page Table of Contents Introduction...5 Hardware Components... 6 Technical Specifications...

More information

TX2123 RS485 TO ETHERNET ADAPTOR

TX2123 RS485 TO ETHERNET ADAPTOR TX2123 RS485 TO ETHERNET ADAPTOR Converts Datacomms between fibre optic Modbus TCP over Ethernet and hard-wired copper Modbus RTU over RS485 Fibre Optic MODBUS TCP/ IP Ethernet Copper MODBUS RTU RS485

More information

NetBiter webscada Modbus User Manual

NetBiter webscada Modbus User Manual User Manual IntelliCom Innovation AB Pilefeltsgatan 93-95 SE-302 50 Halmstad SWEDEN Phone +46 35 17 29 90 Fax +46 35 17 29 09 email info@intellicom.se www www.intellicom.se Revision List Revision Date

More information

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION. Data Bulletin 1210DB0002R3/05 03/2005 LaVergne, TN, USA Communications Wiring for POWERLINK G3 Systems Class 1210 Retain for future use. ABOUT THIS BULLETIN This data bulletin describes the proper wiring

More information

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION

ENET-710. ENET-710 - Ethernet Module ENET-710 JAN / 06 FOUNDATION ENET-710 ENET-710 - Ethernet Module JAN / 06 ENET-710 FOUNDATION E N E T 7 1 0 ME smar www.smar.com Specifications and information are subject to change without notice. Up-to-date address information is

More information

Energy Communication Unit (ECU)

Energy Communication Unit (ECU) Altenergy Power System Energy Communication Unit (ECU) Installation and User Manual (For ECU-3 V3.7) Version:3.0 ALTENERGY POWER SYSTEM INC. All rights reserved TABLE OF CONTENTS 1.0 Introduction... 2

More information

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo206G Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network IPThermo 206G is the central data handling terminal of the IPThermo Pro measurement network. This

More information

TX OPEN RS232/485 module

TX OPEN RS232/485 module s 8 185 8185P01 TX-I/O ; DESIGO OPEN TX OPEN RS/485 module for integrating third-party systems and devices to DESIGO (V4 or higher) TXI1.OPEN Platform to integrate third-party systems and devices to the

More information

Model: DC-A2IO Advanced HVAC Controller

Model: DC-A2IO Advanced HVAC Controller Model: DC-A2IO Advanced HVAC Controller Job Name: Schedule Reference: Date: DC-A2IO Advanced HVAC Controller Package PAC-IF01 M-Net Adapter AL2-14MR-D α2 Simple Application Controller Accessories AL2-2DA

More information

User Manual Revision 2.003 English

User Manual Revision 2.003 English Document code: MN67120_ENG Revision 2.003 Page 1 of 15 User Manual Revision 2.003 English RS232 / RS485 / Ethernet - Converter (Order Code: HD67120) for Website information: www.adfweb.com?product=hd67120

More information

Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

Manual. IP Sensor and Watchdog IPSW2210. I P S W 2 2 1 0 M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry. IP Sensor and Watchdog IPSW2210 Manual Relay Output Power input 12VDC adapter LED Indicators 1 wire 2 Dry Output Green : Power Yellow: Link temperature & humidity contact inputs LED indicator sensor input

More information

Z-TWS4. Multifunction Straton / LINUX Controller. www.seneca.it

Z-TWS4. Multifunction Straton / LINUX Controller. www.seneca.it Z-TWS Multifunction Straton / LINUX Controller OPC Linux High-level Control System suitable for: Energy Management (IEC 0870--0, IEC 0870--0, IEC 80) Plant automation (Straton - Soft PLC IEC -) CPU Linux-based

More information

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section

More information

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3 SIP Proxy Server Administrator Installation and Configuration Guide V2.31b 09SIPXM.SY2.31b.EN3 DSG, DSG logo, InterPBX, InterServer, Blaze Series, VG5000, VG7000, IP590, IP580, IP500, IP510, InterConsole,

More information

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog USER MANUAL PingBrother EPIW104 managed passive poe switch & IP watchdog CONTENT Content... 2 Chapter 1... 3 1.1 Preface... 3 1.2 CE mark warning... 3 1.3 FCC warning... 4 Chapter 2... 5 2.1 Physical description...

More information

Crow Limited Warranty. Print Version 017

Crow Limited Warranty. Print Version 017 Crow Limited Warranty (Crow) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose

More information

Using IDENT M System T with Modbus/TCP

Using IDENT M System T with Modbus/TCP Using IDENT M System T with Modbus/TCP Introduction The Pepperl+Fuchs IDENT M System T consists of two models MTT3000-F180-B12- V45-MON, which is a read only unit and the MTT6000-F120-B12-V45 which is

More information

IntesisBox. Making Building Automation go further. OPC Servers

IntesisBox. Making Building Automation go further. OPC Servers IntesisBox Making Building Automation go further OPC Servers OPC Servers 2009 Intesis Software S.L. All rights reserved. IntesisBox is a registered trademark of Intesis Software SL.. All trademarks and

More information

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual Version 1.0 - January 20, 2015 CHANGE HISTORY Version Date Description of Changes 1.0 January 20, 2015 Initial Publication

More information

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack.

Unpacking the Product. Rack Installation. Then, use the screws provided with the equipment rack to mount the firewall in the rack. About This Guide This guide contains step-by-step instructions for setting up the D-Link DFL-260E/860E Firewall. Please note that the model you have purchased may appear slightly different from those shown

More information

Telephone- and leased line modem for industrial applications TD-36

Telephone- and leased line modem for industrial applications TD-36 Telephone- and leased line modem for industrial applications TD-36 Modem for industrial PSTN- and leased line applications The TD-36 is an analogue V.34 PSTN modem as well as an industrial 2-wire leased

More information

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide 1. Introduction Thank you for purchasing this 16-Port RS232 to USB2.0 High Speed Multi Serial Adapter. It is an

More information

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8 CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection

More information

OZS164... Web server. For LPB/BSB plants

OZS164... Web server. For LPB/BSB plants s 5 711 Web server For LPB/BSB plants OZS164... Remotely operate and monitor a LPB or BSB device Web browser operation via PC/laptop or Smartphone SMS operation via mobile phone (OZS164.23) 2 digital inputs

More information

Premium Server Client Software

Premium Server Client Software Premium Server Client Software Server / Client SMSPro & GSMS TH series Get the tools on hand Premium Server is designed to cover most of the applications in the market. It gives a hassle free management

More information

LevelOne VOI-9000. H.323 VoIP Gatekeeper. User Manual

LevelOne VOI-9000. H.323 VoIP Gatekeeper. User Manual LevelOne VOI-9000 H.323 VoIP Gatekeeper User Manual Quick Guide Step 1: Broadband (ADSL/Cable Modem) Connections For VOI-9000 A. Connect VOI-9000 RJ45 LAN port to Router/ADSL as one of the following connections.

More information

LBNP16312. RS-232/485/422 serial device server. User manual

LBNP16312. RS-232/485/422 serial device server. User manual Tu Sitio de Automatización! LBNP16312 RS-232/485/422 serial device server User manual Summarize-----------------------------------------------------------------------------14-3 Package checklist---------------------------------------------------------------------14-3

More information

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter BIT COMMANDER Serial RS232 / RS485 to Ethernet Converter (Part US2000A) Copyrights U.S. Converters 1 Contents Overview and Features... 3 Functions..5 TCP Server Mode... 5 Httpd Client Mode.5 TCP Auto mode....6

More information

RTU-EN01 Modbus TCP Remote I/O Communication Module Operation Manual

RTU-EN01 Modbus TCP Remote I/O Communication Module Operation Manual RTU-EN01 Modbus TCP Remote I/O Communication Module Operation Manual DVP-0213920-01 Introduction This operation manual only provides introductory information on electrical specification, installation

More information

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7 1 de 7 1. Introduction This Technical Note explains how to configure the Modbus Gateway for Vantage Pro2. The Modbus Gateway allows the easy connection of a PLC (Programmable Logic Controller), RTU (Remote

More information

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ZC-24DO CANopen I/O Module: 24 Digital Outputs Z-PC Line EN ZC-24DO CANopen I/O Module: 24 Digital Outputs Installation Manual Contents: - General Specifications - Technical Specifications - Installation Rules - Electrical connections - DIP-switches

More information

APNT#1168 Modbus - Establishing Communications Hints

APNT#1168 Modbus - Establishing Communications Hints Application Note #1168: Modbus - Establishing Communications Hints Introduction This document provides supplemental information about configuring Pro-face Device/PLC drivers to communicate with your device.

More information

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4 Cable max. 50 m between interface and read/write head Connection of up to 4 read/write heads via BL ident extension cables Mixed operation of HF and UHF read/ write heads Connectors /S2500 Type code Ident

More information

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010) Setup Manual and Programming Reference Stanford Research Systems Revision 1.05 (11/2010) Certification Stanford Research Systems certifies that this product met its published specifications at the time

More information

Software User Guide UG-461

Software User Guide UG-461 Software User Guide UG-461 One Technology Way P.O. Box 9106 Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 Fax: 781.461.3113 www.analog.com ezlinx icoupler Isolated Interface Development Environment

More information

LotWan Appliance User Guide USER GUIDE

LotWan Appliance User Guide USER GUIDE LotWan Appliance User Guide USER GUIDE Copyright Information Copyright 2014, Beijing AppEx Networks Corporation The description, illustrations, pictures, methods and other information contain in this document

More information

TK700 +70 C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W. TK-Series Cellular Router

TK700 +70 C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W. TK-Series Cellular Router +70 C -25 C 95% RH EMC TK701G TK701U TK704G TK704U TK704W The industrial 2G GPRS- and 3G UMTS routers offered by Welotec enables the access to Ethernet devices or a local network remotely via mobile network

More information

VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0

VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0 VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0 1. Installation Requirements 1.1. PC Pentium III processor or higher. Minimum RAM memory: 128 Mbytes Operating system: Windows XP

More information

User Manual. EtherUSB

User Manual. EtherUSB User Manual EtherUSB USB Ethernet Access Point for PDA V 2.0 Clarinet Systems, Inc. Clarinet Systems, Inc. http://www.clarinetsys.com Page 1 Publication Revision No. Control Table Rev. No. Date Contents

More information

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W) Table of Contents Introduction.. Power Over Ethernet (PoE) & Features.... Unpacking and

More information

RS-232/422/485 to 10/100Base-TX Device Server / Managed Media Converter (IRF-633) User s Manual

RS-232/422/485 to 10/100Base-TX Device Server / Managed Media Converter (IRF-633) User s Manual RS-232/422/485 to 10/100Base-TX Device Server / Managed Media Converter (IRF-633) User s Manual COPYRIGHT All rights reserved. No part of this publication may be reproduced, stored in a retrieval system,

More information

1 INTRODUCTION. This document describes the procedure to upgrade LTMR.

1 INTRODUCTION. This document describes the procedure to upgrade LTMR. 1 INTRODUCTION This document describes the procedure to upgrade LTMR. Limitation: this package and procedure describe only the upgrade of the LTMR firmware for all network versions (Modbus, Profibus, DeviceNet,

More information

R-Win. Smart Wireless Communication Management System

R-Win. Smart Wireless Communication Management System Smart Wireless Communication Management System General R-Win is a smart communications adapter for management of wireless communications in a SCADA/Distributed Control System. The R-Win system includes

More information

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide

About This Guide SolarEdge Configuration Tool Software Guide. About This Guide About This Guide 3 About This Guide This user guide is intended for Photovoltaic (PV) system owners, installers, technicians, maintainers, administrators and integrators who are authorized to configure

More information

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology FOSTCDR pn 8684R1 FOSTCDR-0812ds page 1/5 Industrial Serial to Multimode Fiber Optic Converter Data Rates up to 115.2 kbps 2.5 Mile (4 km) Range 10 to 30 VDC Input Voltage Wide Operating Temperature 2000V

More information

Application/Connection Examples

Application/Connection Examples This Quick Start Guide is designed to familiarize the user with the connection and configuration of the DTS-305 DIN rail mounted single / 3 phase power & energy meter with RS-485 or TCP communications.

More information

Medical Vacuum Systems-PXMI

Medical Vacuum Systems-PXMI Medical Vacuum Systems-PXMI Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing

More information

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Manuel d installation Installation manual Part. LE05334AC-07/13-01 GF Daker DK 1, 2, 3 kva Index 1 Introduction 24 2 Conditions of use 24 3 LCD Panel 25 4 Installation 28 5 UPS communicator

More information

IntesisBox DK-RC-ENO-1iC. EnOcean Interface for DAIKIN Air Conditioners Compatible with SKY and VRV lines

IntesisBox DK-RC-ENO-1iC. EnOcean Interface for DAIKIN Air Conditioners Compatible with SKY and VRV lines IntesisBox DK-RC-ENO-1i DK-RC-ENO-1iC EnOcean Interface for DAIKIN Air Conditioners Compatible with SKY and VRV lines User's Manual r1 eng Issue Date: 02/2012 Intesis Software S.L. All Rights Reserved.

More information

Technical Information POWER PLANT CONTROLLER

Technical Information POWER PLANT CONTROLLER Technical Information POWER PLANT CONTROLLER Content The Power Plant Controller offers intelligent and flexible solutions for the control of all PV power plants in the megawatt range. It is suitable for

More information

VTO6xxx. IP door stations. User manual

VTO6xxx. IP door stations. User manual VTO6xxx IP door stations User manual Table of Contents 1 Product Appearance 2 Basic Function Introduction 2.1 Call Manager Center 2.2 Call User 2.2.1 Connecting Status 2.2.2 Calling Status 2.3 Monitor

More information

F453. TiF453. User guide 10/11-01 PC

F453. TiF453. User guide 10/11-01 PC F453 TiF453 User guide 10/11-01 PC 2 TiF453 User guide Contents 1. Hardware and Software requirements 4 2. Installation 4 1.1 Minimum Hardware requirements 4 1.2 Minimum Software requirements 4 3. Fundamental

More information

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB Product Manual ABB i-bus KNX IP Interface IPS/S 2.1 Intelligent Installation Systems ABB This manual describes the function of the IP Interface IPS/S 2.1 with the application program IP Interface. Subject

More information

Communication standards and Carel solutions

Communication standards and Carel solutions Brugine March 2002 Communication standards and Carel solutions Modbus All Carel controllers: GATEWAYMB0 pco 2 - Direct connection through RS232 serial card PCO200MDM0 RS485 serial card PCO2004850 BIOS

More information

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER Application : The RISH CON - Hz transducer is used for frequency measurement. The output signal is proportional to measured frequency and is either load independent DC Current or load independent DC Voltage.

More information

Network Camera. Quick Operation Guide V4.0.1

Network Camera. Quick Operation Guide V4.0.1 Network Camera Quick Operation Guide V4.0.1 Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to DS-2CD8253F-EI(Z),

More information

Disclaimers. Important Notice

Disclaimers. Important Notice Disclaimers Disclaimers Important Notice Copyright SolarEdge Inc. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means,

More information

Electronic Control Devices The European Product Catalogue 2007

Electronic Control Devices The European Product Catalogue 2007 FX07 Field Controller (1/4) FX07 Field Controller Display Model Dimensions in mm (inches) The FX07 is a terminal unit controller in the Facility Explorer range of products. The controller is designed specifically

More information

Network Management Card. User Manual

Network Management Card. User Manual User Manual 1 Contents Contents 2 Chapter 1 Overview 3 1.1 NMC package contents 4 1.2 NMC CD Resources 4 1.3 Features 4 1.4 NMC Applications 5 Chapter 2 NMC parameters setting via serial COM port 6 2.1

More information

connecdim Gateway G1 Ethernet TCP/IP to DALI

connecdim Gateway G1 Ethernet TCP/IP to DALI Gateway G1 Ethernet TCP/IP to LI Independent lighting control for up to 256 LI gears on 4 LI lines Can be expanded by connecting multiple gateways on the same network Cloud based web interface for configuration

More information

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

TRP-C31M MODBUS TCP to RTU/ASCII Gateway TRP-C31M MODBUS TCP to RTU/ASCII Gateway User s Manual Printed Feb. 2007 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172

More information

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English xepi 2 Diagnostic Unit and Configuration Interface Doc. Version 4.0 Installation Guide English Dear Customer, This "Installation Guide" will help you to install the hardware. If you have any further questions,

More information

ewon COSY 141 Installation Guide

ewon COSY 141 Installation Guide ewon Installation Guide IG 010 / Rev 1.2 Contents ewon COSY 141 Installation Guide This short guide explains how to install ewon COSY 141 and to get started with the embedded configuration web site. Table

More information

for Windows Media Center User's Guide

for Windows Media Center User's Guide for Windows Media Center User's Guide Table of Contents Introduction System Requirements Installation Running HAI Home Control Using HAI Home Control Product Support Introduction Thank you for purchasing

More information

HARTING mcon 1000 Introduction and features

HARTING mcon 1000 Introduction and features Introduction and features HARTING mcon 1000 es, managed, for mounting onto top-hat mounting rail in control cabinets General Description Features Supporting Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s)

More information

Monitoring and control have never been this easy

Monitoring and control have never been this easy TelevisGo Monitoring and control have never been this easy MANAGEMENT AND MONITORING TelevisGo is a family of devices used to monitor, control and manage commercial refrigeration installations from a distance.

More information