Pilot Operated 2 Port Solenoid Valve for Dry Air

Similar documents
3 Port Solenoid Valve

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

3 Port Solenoid Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Assisted lift operated 2/2-way solenoid valves Type EV250B

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

Cable Plug acc. to DIN EN , Form A

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Single sub-base valve

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

Precision Regulator. Series IR1000/2000/3000 ARJ AMR ARM ARP IR IRV VEX1 SRH SRP SRF ARX20 VCHR ITV IC PVQ VER VEA VY2 AP100.

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

3/2-way Solenoid Valve, direct-acting, NC or NO

Electro-pneumatic control valves

5 Port Solenoid Valve

System 8. ü ( System 8

STC 3S A Series Solenoid Valves

4 Posiflow Proportional Solenoid Valves

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Capacitive Prox E2K-X

LCD Readout Digital Pressure Switch

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

2/2 and 3/2 Way Size 6 Seat Valves

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Cross-beam scanning system to detect slim objects. 100 mm in

Valves. Sub-Base Mounted Valves to ISO 5599/2

RY2 miniature industrial relays

STC 2P050 Series Solenoid Valves NSF Compliant Materials, 2 Way, Direct Acting

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Unit 24: Applications of Pneumatics and Hydraulics

Adjustment functions for both span and shift have been incorporated

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

3/2- and 2/2-way cartridge valve type BVE

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Solenoid valves 2/2-way direct-operated Type EV210A

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Line-Mounted Valves L Series

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Solenoid valves Type EVU

type V46, solenoid or pneumatic operated

Proportional pressure regulators VPPE

Solenoid Valve Island Type 3965

VSO MAX HP High Flow Proportional Valve

TS93 EMR T/PT/TDE. Surface applied door closer

Modular I/O System Analog and Digital Interface Modules

Electro-Pneumatic Bus Door Control Mechanism

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

NAMUR Mount Hygienic Valve

4/2-Way Pneumatic Solenoid Valve

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

SOLENOID VALVE FOR REFRIGERATING SYSTEMS

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Cooling system components, removing and installing

SOLENOID VALVES AND PNEUMATIC VALVES

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

G1/4 Q8. Standard with biased position

Cooling system components, removing and installing

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

IOM SERIES 820-E/P Electro-Pneumatic Positioner

For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } {175}

SQUARE D INDUSTRIAL CONTROL PRODUCTS

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

Process Valve. 2 Port Valve For Compressed Air and Air-hydro Circuit Control

Chapter 6: Check Valves

U-shaped Micro Photoelectric Sensor

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

Model Number Structure

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

How To Read A Pipe From A Sensor

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

How To Use A Flowmeter

! WARNING. Before using product, read and understand instructions.

3/2-way pneumatic cartridge solenoid valve

UM/ /2 & 5/3 valves, solenoid and pilot actuated ISO , ISO size 1, 2, 3 & 4 Sub-base mounted

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

Digital inductive conductivity transmitter


Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

Transcription:

Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Compact and lightweight with large flow capacity [Option] VQ0 Weight (g) 46 80 C [dm 3 /(s bar)].5 (C8) 3.0 (C) Series Series VQ0 VCH VDW VQ LVM High frequency operation possible High speed response 7 ms or less (VQ0), 0 ms or less () (High speed response type without light/surge voltage suppressor at the supply pressure of 0.5 MPa) Long operating life Easy piping with One-touch Fittings Dusttight low jetproof enclosure (IP65) compliant in DIN terminal type. Application: Air-blow, Blow-off of workpiece, etc. 43

Pilot Operated For Dry Air Port Solenoid Valve Series VQ0/30 Single Unit [Option] How to Order Valves VQ A G C6 Series/ Orifice diameter Symbol 3 N.C. Series VQ0 Valve type (OUT) Option : None F: With bracket CE-compliant Q CE-compliant Made to Order specifications (Refer to the table below) A: Single unit (IN) Body type Manual override None Note) Slotted locking type B (tool required) Note) Only normally closed DIN terminal in-line style is applicable. L: Type L (VQ0 only) Note) If ordering both options, indicate LF. M: For manifold 3 5 6 9 Note ) G: Grommet Coil voltage 00 VAC (50/60 Hz) 00 VAC (50/60 Hz) 0 VAC (50/60 Hz) 4 VDC VDC Other special voltage Note ) Please consult with SMC for special voltages. Note ) There is polarity for DC voltage (with power-saving circuit type). Y: DIN terminal YO: DIN terminal without connector Electrical entry Electricity circuit Symbol DC voltage With power-saving circuit (With surge voltage suppressor protection circuit) With power-saving circuit Z (With light/surge voltage suppressor protection circuit) Note) High speed response type H (Without energy-saving, light/surge voltage suppressor circuit) Note) H is available only for DC voltage and cannot be energized continuously. Made to Order Specifications Oil-free specifications VQ A 3M VQ A 3M Seal material fluororubber/oil-free specifications VQ A 3 M Note) Not available for manual operation. Port size Symbol Port size C6 C8 C0 C One-touch fitting for ø6 One-touch fitting for ø8 One-touch fitting for ø0 One-touch fitting for ø AC voltage With full wave rectifier circuit (With surge voltage suppressor protection circuit) With full wave rectifier circuit (With light/surge voltage suppressor protection circuit) VQ0 X(-Q) X5(-Q) X3(-Q) Please contact SMC for further specifications, delivery and price. Note) Please consult with SMC when using. Not available for manual operation. Seal material fluororubber specifications A 44

Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Standard Specifications VQ0 Valve specifications Series Valve construction Fluid Ambient and fluid temperature Lubrication Manual override Impact resistance/vibration resistance Enclosure Internal leakage cm 3 /min Exterior leakage cm 3 /min Mounting orientation Weight VQ0 port poppet pilot operated Note ) Air Note ) 0 to 50 C Not required Note 3) Slotted locking type (tool required) 50/30 m/s Note 4) Note 5) Dustproof 5 or less 5 or less Unrestricted 46 g 80 g Symbol (OUT) (IN) N.C. Electric specifications Coil rated voltage Allowable voltage fluctuation Coil insulation type VDC, 4 VDC, 00 VAC, 0 VAC, 00 VAC ±0% of rated voltage Class B or equivalent Power DC voltage (with power-saving circuit) Inrush:.9 W, Holding: 0.6 W consumption DC voltage (without power-saving circuit).9 W (Current value) AC VA Electrical entry Grommet, DIN terminal Note ) This product is for dry air. Use in clean air, and be sure that drain and oil content does not flow into the product. Note ) Use dry air to prevent condensation when operating at low temperatures. Note 3) Manual override is available only for DIN terminal type. Note 4) Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 000 Hz. Test was performed at both energized and de-energized states to the axis and right angle directions of the main valve and armature (value at the initial state). Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve and armature for both energized and de-energized states (value at the initial state). Note 5) DIN terminal type: Applicable to dusttight and low jetproof (IP65). Characteristic Specifications Series VQ0 Port size ø6 ø8 ø0 ø Flow characteristics C [dm 3 /(s bar)] b Cv.4 0.3 0.33.5 0.4 0.39.8 0.4 0.80 3.0 0.37 0.8 Min. operating pressure differential Note 3) 0.0 MPa Max. operating pressure 0.6 MPa 0.5 MPa Note ) Note ) Electricity circuit With power-saving circuit High speed response type With power-saving circuit High speed response type Note ) Response time ON OFF 0 ms or less 5 ms or less 7 ms or less 5 ms or less 5 ms or less 5 ms or less 0 ms or less 5 ms or less VCH VDW VQ LVM Construction Note ) JIS B 8375 (value of DC voltage specifications at 0.5 MPa supply pressure) (Value of high response time is subject to change upon pressure, quality of air.) Note ) It cannot be used when energized continuously. Note 3) If a restrictor (nozzle, etc.) is mounted on the outlet side piping, the pressure differential when ON is smaller. Be sure that the pressure differential does not drop below 0.0 MPa. Additionally, take great care when used for the ejector supply, etc. w e q r t y u Component Parts No. 3 4 5 6 7 Description Solenoid coil Body Fixed armature Armature Return spring Poppet Diaphragm assembly Material Resin Stainless steel Stainless steel Stainless steel NBR H NBR, Resin 45 C

Series VQ0/30 Dimensions: Series VQ0 In-line Type: Grommet (G) VQA-G- - Mounting holes x ø3. through Bracket mounting holes x ø3. through Light Lead wire length Approx. 300 P port C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 Dotted line: Bracket mounting style (-F) 46

Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Dimensions: Series VQ0 Type L: Grommet (G) VQA-G- -L Light Lead wire length Approx. 300 VCH VDW P port C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 VQ LVM C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 x ø3. mounting hole Dotted line: Bracket mounting style (-LF) 47 A

Series VQ0/30 Dimensions: Series VQ0 In-line Type: DIN terminal (Y) VQA-Y- - Mounting hole x ø3. through Bracket mounting hole x ø3. through Manual override Applicable cable O.D. ø3.5 to ø7.0 mm P port C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 Dotted line: Bracket mounting style (-F) 48

Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Dimensions: Series In-line Type: Grommet (G) VQ3A-G- - Mounting hole x ø4.3 through Bracket mounting hole x ø4.5 through Light Lead wire length Approx. 300 VCH VDW VQ LVM P port C0: One-touch fitting for ø0 C: One-touch fitting for ø C0: One-touch fitting for ø0 C: One-touch fitting for ø Dotted line: Bracket mounting style (-F) 49

Series VQ0/30 Dimensions: Series DIN terminal (Y) VQ3A-Y- - Mounting hole x ø4.3 through Bracket mounting hole x ø4.5 through Manual override Applicable cable O.D. ø3.5 to ø7.0 mm P port C0: One-touch fitting for ø0 C: One-touch fitting for ø C0: One-touch fitting for ø0 C: One-touch fitting for ø Dotted line: Bracket mounting style (-F) 430

Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 How to Order Manifold VVQ 08 3 Series VQ0 Stations 0 station 0 0 stations Option D DO P port/thread type 00N 00T 00F CE-compliant Q CE-compliant Rc 3/8 NPT 3/8 NPTF 3/8 G 3/8 None DIN rail mounting DIN rail mounting (Without DIN rail) How to Order Manifold Assembly Enter the mounting valve and option part numbers under the manifold base part number. <Ordering Example> VVQ-05 (-Q) set Manifold part No. VQM-5G-C6 (-Q) 4 sets Valve part No. (Stations to 4) VQM-5G-C8 (-Q) set Valve part No. (Station 5) is the symbol for assembly. Add a in front of the part numbers for solenoid valves, etc., to be mounted. Stations 3 U side D side Enter together in order, counting from station on the D side. [Option] P How to Order Valves (For Manifold) Series/ Orifice diameter Symbol Series VQ0 3 Valve specifications M Manifold G Y YO Valve Type N.C. (OUT) VQ M G C6 (IN) Electrical entry Grommet DIN terminal DIN terminal (without connector) 3 5 6 9 Note ) Coil voltage 00 VAC (50/60 Hz) 00 VAC 0 VAC 4 VDC VDC Other special voltage Note ) Please consult with SMC for special voltages. Note ) There is polarity for DC voltage (with power-saving circuit type). Electricity circuit Symbol Z H Note) Port size Symbol C6 C8 C0 C DC voltage With power-saving circuit (with surge voltage suppressor protection circuit) With power-saving circuit (with light/surge voltage suppressor protection circuit) High speed response type (without energy-saving, light/surge voltage suppressor circuit) Made to Order specifications Q (Refer to the table below) Port size One-touch fitting for ø6 One-touch fitting for ø8 One-touch fitting for ø0 One-touch fitting for ø VQ0 Manual override None B Note) Slotted locking type (tool required) Note) Only normally closed DIN terminal in-line style is applicable. Note) H is available only for DC voltage and cannot be energized continuously. CE-compliant CE-compliant AC voltage With full wave rectifier circuit (with surge voltage suppressor protection circuit) With full wave rectifier circuit (with light/surge voltage suppressor protection circuit) VCH VDW VQ LVM Made to Order Specifications Please contact SMC for further specifications, delivery and price. Oil-free specifications VQ 3 M X (-Q) Note) Please consult with SMC when using. Not available for manual operation. Seal material fluororubber specifications VQ 3 M X5 (-Q) 43 A

Series VQ0/30 Dimensions Plug lead unit manifold (VVQ- ) Mounting hole x ø4.5 through C6: One-touch fitting for ø6 C8: One-touch fitting for ø8 x Rc 3/8 DIN rail mounting 4 x M3 x 0.5 Dotted line: DIN rail mounting (-D) Dimensions L L L L3 L4 L5 n 3 4 5 6 7 8 9 0 78 68 07 97 36 6 65 55 94 84 3 3 5 4 8 7 30 300 00 37.5 6.5 87.5.5 50 75 300 337.5 0.5 48 73 98 3 60.5 85.5 30.5 348 66.8 95.8 4.8 53.8 8.8.8 40.8 69.8 98.8 49 39 75 85.5 37.8 Formulas L = (n ) x 9 + 49 L = L 0 L3 = L4 0.5 L5 = L. n: Station (Max. 0) 3 4 5 6 7 8 9 0 339 368 397 46 455 484 53 54 57 600 39 358 387 46 445 474 503 53 56 590 36.5 387.5 45 450 475 500 537.5 56.5 587.5 65 373 398 435.5 460.5 485.5 50.5 548 573 598 635.5 37.8 356.8 385.8 44.8 443.8 47.8 50.8 530.8 559.8 588.8 43

Pilot Operated Port Solenoid Valve for Dry Air Series VQ0/30 Dimensions Plug lead unit manifold (VVQ3- ) Mounting hole x ø4.5 through C0: One-touch fitting for ø0 C: One-touch fitting for ø x Rc 3/8 VCH VDW VQ LVM DIN rail mounting 4 x M3 x 0.5 Dotted line: DIN rail mounting (-D) Formulas L = (n ) x 37 + 56 L = L 0 L3 = L4 0.5 L5 = L. Dimensions n: Station (Max. 0) L n 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 L L 56 46 93 83 30 0 67 57 04 94 4 3 78 68 35 305 35 34 389 379 46 46 463 453 500 490 537 57 574 564 6 60 648 638 685 675 7 7 759 749 L3 75.5 50 87.5 5 6.5 300 337.5 375 4.5 450 487.5 55 56.5 587.5 65 66.5 700 737.5 775 L4 85.5 3 60.5 98 35.5 73 30.5 348 385.5 43 460.5 498 535.5 573 598 635.5 673 70.5 748 785.5 L5 44.8 8.8 8.8 55.8 9.8 9.8 66.8 303.8 340.8 377.8 44.8 45.8 488.8 55.8 56.8 599.8 636.8 673.8 70.8 747.8 433

Series VQ0/30 Single Unit Option Bracket assembly (with mounting screws) For fixing this solenoid valve. Type VQ0 Grommet in-line type VQ0 Grommet L type, DIN terminal type DIN terminal L type Bracket assembly AXT835-3A AXT835-3A- AXT835-3A-3 AXT837-3A (Mounting screws, pcs.) M3 x 45 M3 x 40 M3 x 35 M4 x 45 Manifold Option DIN rail AXT00-DR- L.5 (Pitch) 5.5 7.5 Suffix the number from DIN rail dimensions table below. Refer to the dimension drawing for each manifold for L dimension. 5.5 35 5 Each manifold can be mounted on a DIN rail. Order with the option symbol -D to specify DIN rail mounting style. The DIN rail is approximately 30 mm longer than the length of manifold. L dimension Series VQ0 Stations No. L.5 3 4 5 6 7 8 9 0 3 4 5 6 7 8 9 0 6 8 3 5 7 0 4 7 9 3 34 36 38 40 43 45 47 50 85.5 0.5 48 73 98 3 60.5 85.5 30.5 348 373 398 435.5 460.5 485.5 50.5 548 573 598 635.5 Series Stations No. 6 9 3 4 5 5 8 6 7 4 8 7 9 30 0 33 36 39 3 4 4 45 5 47 6 50 7 53 8 56 9 59 0 6 L 85.5 3 60.5 98 35.5 73 30.5 348 385.5 43 460.5 498 535.5 573 598 635.5 673 70.5 748 785.5 DIN rail mounting bracket VVQZ00-DB-5 This bracket is used for mounting the manifold on the DIN rail. DIN rail mounting bracket is attached on the manifold. set of DIN rail mounting brackets for manifold includes brackets. Blanking plate assembly (with O-ring and mounting screws) Mount a blank plate on valve manifold when a valve is disassembled for maintenance purposes, or when spare valve unit is supposed to be mounted in the future. Series VQ0 Blanking plate assembly AXT835-35A AXT837-35A (O-ring) OR-679-00-H OR-400-50-H (Mounting screws, pcs.) M3 x 6 M4 x 6 434

Series VQ0/30 Specific Product Precautions Be sure to read before handling. Refer to front matter 4 for Safety Instructions, and pages 7 to 9 for Port Solenoid Valves for Fluid Control Precautions. Warning Selection. Air quality This product is for dry air. Drain, oil, etc. in the air may result in faulty operation. Use clean (dry) air.. Pressure differential If a restrictor (nozzle, etc.) is mounted on the outlet side, the outlet side pressure differential at the inlet side is smaller. Be sure the pressure differential when ON does not drop below 0.0 MPa. Manual Override Warning Regardless of electric signals to the solenoid valve, the manual override is used for switching the main valve. (DIN terminal only.) Push the manual override Slotted locking type (tool required) button with a small flat head screwdriver until it stops. Turn it in the counterclockwise direction at ø3.8 90 to lock the manual. Turn it right to release. LED PUSH Timer circuit TURN LOCK Connection and Electrical Circuit Caution Black ( ) DC Blue (00 VAC) Red (00 VAC) Red (+) DC Blue (00 VAC) Red (00 VAC) With DC voltage power-saving circuit (with polarity) Lead wire color DIN connector Red (+) SOL. Connection and Electrical Circuit Caution Power wave form of power-saving type (Rated voltage at 4 VDC) Applied voltage 4 V 0 V 0 to 0 ms.9 W Power-saving 0.6 W 0 W AC circuit Lead wire color DIN connector Blue (00 VAC), Red (00 VAC) Blue (00 VAC), Red (00 VAC) Caution Valve Mounting When mounting the valve, secure with brackets. When mounting it directly, tighten the mounting screws with the appropriate torque (0.7 to 0.8 N m). Mounting screw Tightening torque 0.7 to 0.8 N m LED When Energizing Continuously for Long Period of Time SOL. Caution When energizing continuously, choose the option of an energysaving circuit specifications. High speed response type (with no energy-saving circuit) cannot be energized continuously. VCH VDW VQ LVM Black ( ) i i i: Inrush current, i: Holding current DC (with power-saving circuit) specifications is designed to reduce the power consumption at holding to achieve powersaving by circuit shown above. Refer to below power wave form. 435

Series VQ0/30 Specific Product Precautions Be sure to read before handling. Refer to front matter 4 for Safety Instructions, and pages 7 to 9 for Port Solenoid Valves for Fluid Control Precautions. How to Wire DIN Terminal Caution ISO#: Based on DIN 43650C (Pin gap 8 mm) Connection. Loosen the tightening screw and pull the connector off of the solenoid valve.. After removing the tightening screw, divide the terminal block and housing by prying open the slot area of the lower part of the terminal block open with a screwdriver. 3. Loosen the terminal screws of the block and insert stripped lead wires in accordance with the wiring diagram. Secure each wire by re-tightening the terminal screw (In the case of terminal : (+), : (-) DC) 4. Tighten the ground nut to secure the cable wire. Change of electrical entry Wire entry can be changed by mounting the housing in either direction (four directions at every 90 ) after dividing the terminal block and the housing. For the indicator lighted style, be careful not to damage the light with the lead wire of the cable. Precautions Insert a connector straight or pull it out straight, using caution it does not be tilted. Applicable cable Cord O.D.: ø3.5 to ø7 (Reference) 0.5 mm -core and 3-core wire equivalent to JIS C 3306. Ground nut Tightening torque.65 to.5 N m Washer Grommet (Rubber) (Voltage symbol) Refer to the following table Tightening torque 0. to 0.5 N m Terminal screw (3 positions) Tightening screw Tightening torque 0.3 to 0.4 N m Housing (Position for light mounting) Terminal block Shaved part DIN Terminal Part No. (Based on DIN) Without indicator light SY00-8-4 With Indicator Light Rated voltage Voltage symbol Part no. 4 VDC VDC 00 VAC 00 VAC 0 VAC 4 V V 00 V 00 V 0 V SY00-8-3-05 SY00-8-3-06 SY00-8--0 SY00-8--0 SY00-8--03 DIN Terminal Circuit with Indicator Light AC circuit How to Wire DIN Terminal NL R NL: Neon light R: Resistor Manifold How to Mount/Remove from DIN Rail Caution Removing procedure. Loosen the clamp screw on the A side of both ends of the manifold.. Lift the A side of the manifold off the DIN rail and slide it in the direction of the arrow. Mounting procedure. Hook the mounting hook on the B side of the manifold base to the DIN rail.. Press down side A and mount the end plate on the DIN rail. Tighten the clamp screw on side B of the end plate. (Tightening torque: 0.3 to 0.4 N m). Caution Valve Mounting DC circuit LED R LED: Light emitting diode R: Resistor After confirming the gasket is correctly placed under the valve, tighten the mounting screws with the appropriate torque (0.7 to 0.8 N m). A Manifold mounting screw B Manifold mounting screw 436