PHENIX Focus: Ring Image CHerenkov counter K. Ozawa For the RICH group



Similar documents
Single photon detection with H8500 MAPMTs for the CBM RICH detector*

The accurate calibration of all detectors is crucial for the subsequent data

The data acquisition system of the XMASS experiment

Status of ALICE activities within FKPPL LIA

PoS(PhotoDet 2012)068

An option for the SHiP Muon Detector: Scintillator bars with WLS fibers and SiPMs readout

Nara Women s University, Nara, Japan B.A. Honors in physics 2002 March 31 Thesis: Particle Production in Relativistic Heavy Ion Collisions

Development of the electromagnetic calorimeter waveform digitizers for the Fermilab Muon g-2 experiment

Silicon Seminar. Optolinks and Off Detector Electronics in ATLAS Pixel Detector

Electron-Muon Ranger (EMR)

07 - Cherenkov and transition radiation detectors

Results from first tests of TRD prototypes for CBM. DPG Frühjahrstagung Münster 2011 Pascal Dillenseger Institut für Kernphysik Frankfurt am Main

Information about the T9 beam line and experimental facilities

(Amplifying) Photo Detectors: Avalanche Photodiodes Silicon Photomultiplier

CMS Tracking Performance Results from early LHC Running

Status of NectarCAM camera project. J-F. Glicenstein (IRFU) for the NectarCAM consortium

Track Trigger and Modules For the HLT

THE DØ Luminosity Monitor (LM) consists of two array of

MICE detectors and first results. M. Bonesini Sezione INFN Milano Bicocca

S2000 Spectrometer Data Sheet

Event viewer for HRS-L

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

ATOMIC SPECTRA. Apparatus: Optical spectrometer, spectral tubes, power supply, incandescent lamp, bottles of dyed water, elevating jack or block.


2 Absorbing Solar Energy

Realization of a UV fisheye hyperspectral camera

Neutron Detection Setups proposed for

Evaluation Tools for the Performance of a NESTOR Test Detector

ATLAS Tile Calorimeter Readout Electronics Upgrade Program for the High Luminosity LHC

Solar Energy. Outline. Solar radiation. What is light?-- Electromagnetic Radiation. Light - Electromagnetic wave spectrum. Electromagnetic Radiation

Radiation Strip Thickness Measurement Systems

Development of on line monitor detectors used for clinical routine in proton and ion therapy

High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules

Testing thermo-acoustic sound generation in water with proton and laser beams

Proton tracking for medical imaging and dosimetry

Electron-Muon Ranger (EMR)

Calorimetry in particle physics experiments

The new frontier of the DATA acquisition using 1 and 10 Gb/s Ethernet links. Filippo Costa on behalf of the ALICE DAQ group

Synthetic Sensing: Proximity / Distance Sensors

ISTITUTO NAZIONALE DI FISICA NUCLEARE

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

AS COMPETITION PAPER 2008

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

How To Use An Ionsonic Microscope

CONFOCAL LASER SCANNING MICROSCOPY TUTORIAL

Calibration and performance test of the Very Front End electronics for the CMS electromagnetic calorimeter

UNI EN ISO 9001 CERT. N CAEN November 2006 EURITRACK Workshop

Application Report: Running µshape TM on a VF-20 Interferometer

Introduction to flow cytometry

Silicon Lab Bonn. Physikalisches Institut Universität Bonn. DEPFET Test System Test DESY

A Gigabit Transceiver for Data Transmission in Future HEP Experiments and An overview of optoelectronics in HEP

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

How To Understand Light And Color

Applications: X-ray Microtomography, Streak Tube and CRT Readout, Industrial & Medical Imaging X-RAY GROUP

arxiv:physics/ v1 [physics.ins-det] 6 Nov 1998

Febex Data Acquisition System

3D SCANNERTM. 3D Scanning Comes Full Circle. s u n. Your Most Valuable QA and Dosimetry Tools A / B / C. The 3D SCANNER Advantage

UN PICCOLO BIG BANG IN LABORATORIO: L'ESPERIMENTO ALICE AD LHC

Radiation Detection and Measurement

CMS Tracker module / hybrid tests and DAQ development for the HL-LHC

Vacuum Evaporation Recap

IMPROVED CCD DETECTORS FOR HIGH SPEED, CHARGE EXCHANGE SPECTROSCOPY STUDIES ON THE DIII D TOKAMAK

Research Management Plan (RMP) for the. STAR Heavy Flavor Tracker (HFT)

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

- thus, the total number of atoms per second that absorb a photon is

CHAPTER 7 SCINTILLATION COUNTING

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

The Muon Veto DAQ. Florian Ritter. Kepler Center for Astro and Particle Physics. Eberhard Karls Universität Tübingen

Nuclear Physics and Radioactivity

Experiment 5. Lasers and laser mode structure

APPLICATION NOTE AP050830

High Energy Physics. Lecture 4 More kinematics and a picture show of particle collisions

T(CR)3IC Testbed for Coherent Radio Cherenkov Radiation from Cosmic-Ray Induced Cascades

Cross section, Flux, Luminosity, Scattering Rates

PHYSICAL QUANTITIES AND UNITS

X 4 CONFIDENTIAL X 4 OTHER PROGRAMME: CUSTOMER: CONTRACT NO.: WPD NO.: DRD NO.: CONTRACTUAL DOC.:

Timing Errors and Jitter

Note monitors controlled by analog signals CRT monitors are controlled by analog voltage. i. e. the level of analog signal delivered through the

arxiv:nucl-ex/ v2 18 Jul 2005

A Digital Spectrometer Approach to Obtaining Multiple Time-Resolved Gamma-Ray. Spectra for Pulsed Spectroscopy. W. K. Warburton a

EMR project Overview

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

Physics 30 Worksheet # 14: Michelson Experiment

Gamma Rays OBJECT: READINGS: APPARATUS: BACKGROUND:

Electron-Muon Ranger (EMR)

Calculation of Source-detector Solid Angle, Using Monte Carlo Method, for Radioactive Sources with Various Geometries and Cylindrical Detector

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Description: Multiparameter System (4 or 8 channels)

Measurement of the Mass of the Top Quark in the l+ Jets Channel Using the Matrix Element Method

X-ray Imaging Systems

X- and Gamma Ray Imaging Systems based on CdTe-CMOS Detector Technology

Grasshopper3 U3. Point Grey Research Inc Riverside Way Richmond, BC Canada V6W 1K7 T (604)

Masses in Atomic Units

1 Experiments (Brahms, PHENIX, and STAR)

A More Efficient Way to De-shelve 137 Ba +

Construction of an Alpha- Beta and Gamma-Sensitive Radiation Detector on the Basis of a Low-Cost PIN-Diode

Experiment #5: Qualitative Absorption Spectroscopy

Thea Omni Light. Thea Spot Light. Light setup & Optimization

Transcription:

PHENIX Focus: Ring Image CHerenkov counter K. Ozawa For the RICH group 12/16/2003 PHENIX Focus, K. Ozawa 1

RICH in reality Ring Image CHrenkov counter (RICH) Contents: RICH in reality Gas, Mirror, PMT and Electronics What can we do with this detector? How do we analyze data? I hope you will be interested in electron measurements and will be a subsystem assistant after this talk. What a large detector!! Large gas volume! - 40 m 3 /arm Large mirror! - 20 m 2 /arm So many PMT s! - 2560 /arm 12/16/2003 PHENIX Focus, K. Ozawa 2

Integration of RICH Purpose of this section Be familiar with RICH components Gas vessel Mirror PMT and arrays Electronics 12/16/2003 PHENIX Focus, K. Ozawa 3

How do we use gas? When a particle travels in gas volume, If particle speed exceeding the speed of light in gas (c/n) Photons are radiated Cherenkov lights! Particle (β > 1/ n) L GAS (radiator) Index:n θ c Threshold of light emission β > 1/ n Emission angle cosθ c =(βn) -1 Light Yield Proportional to L and sin 2 θ c If momentum is known, we can IDENTIFY particle using Cherenkov light measurements. 12/16/2003 PHENIX Focus, K. Ozawa 4

Specifics in PHENIX RICH Threshold depends on the reflection index of gas. CO 2 : n=1.000410, γ th = 35 P th = Mass * γ th * β th = Mass * γ th /n Electron: 0.02 GeV/c, π: 4.9 GeV/c We can identify electron from 0.02 to 4.9 GeV/c. RICH is Primary electron ID device of PHENIX. Maximize Light Yield the length of the radiator. We need LARGE gas vessel. The vessels are designed and fabricated at Florida State University 12/16/2003 PHENIX Focus, K. Ozawa 5

Mirror and ring Cherenkov photons emitted in parallel. Using spherical mirror, photons are focused on PMT surface. Photons make a ring. Acceptance 12/16/2003 PHENIX Focus, K. Ozawa 6

PMT and arrays Photon detection device Hamamatsu H3171S Cathode Diameter: 25 mm Tube Diameter: 29 mm Cathode: Bialkali The arrays are Gain: > 10 7 fabricated at SUNY Operation Voltage: -1400 ~ -1800V Rise Time: < 2.5ns Transit Time Spread: < 750ps A Winstone cone shaped conical mirror is attached to each PMT Entrance: 50 mm, Cut off: 30 Supermodule (2x16 PMTs grouped) 40 super-modules per one side 4 sides * 40 * 2* 16 = 5120 PMTs 8 PMTs share the same HV channel pixel size 1 degree x 1 degree 12/16/2003 PHENIX Focus, K. Ozawa 7

Electronics Readout Signals from 5120 PMTs 0 10 Photon Detection with 10 bits Time Resolution: 200 ps (For Background Rejection) Compactness Processes 640 PMT Signals per Crate 9U VME Dimensions One Controller Module Two Trigger Modules Two Readout Modules Ten Analog Modules 12/16/2003 PHENIX Focus, K. Ozawa 8

Summary of hardware Electron go thorough the RICH gas volume, Cherenkov photons emitted Photons are reflected by mirror and focused on the PMT surface PMT detect photons Identify electron from 0.02 to 4.9 GeV/c. Most hadrons do not emit Cerenkov light PMT array Cerenkov photons from mirror e + or e - are detected by array of PMTs PMT array Electrons Central Magnet emit Cerenkov photons in RICH. 12/16/2003 PHENIX Focus, K. Ozawa 9

What can we do with RICH? Measure several kinds of proposed QGP signals. Deconfinement J/Ψ to e+e- Chiral Symmetry Restoration Mass, width, branching ratio of φ to e+e-, K+K- with δm < 5 MeV Thermal Radiation of Hot Gas Prompt γ * to e+e- Strangeness and Charm Production Production of φ, J/Ψ, D mesons Single electron Electron ID is essential for above measurements. 12/16/2003 PHENIX Focus, K. Ozawa 10

Charm production production mainly via gg fusion in earliest stage of collision sensitive to initial gluon density additional thermal production at very high temperature sensitive to initial temperature c c D 0 K + l ν l K l + ν l D 0 Figure by R. Averbeck Indirect Measurement heavy flavor semi leptonic decays contribute to single lepton and lepton pair spectra 12/16/2003 PHENIX Focus, K. Ozawa 11

Single electron γ conversio π 0 γee n η γee, 3π 0 ω ee, π 0 ee φ ee, ηee Electrons from photonic source is subtracted from inclusive spectrum. Electrons from non-photonic source is consistent with PYTHIA results normalized by N_binary. ρ ee η γee We will soon have a similar results for dau data. 12/16/2003 PHENIX Focus, K. Ozawa 12

J/Ψ to e + e - J/Ψ suppression Predicted by Matsui and Satz Phys. Lett. B178, 416 (1986) Debye screening mechanism Consider normal nuclear absorption J/Ψ enhancement Effects of recombination c c Perturbative Vacuum We have to measure J/Y yield carefully. Electron pair Invariant Mass Run2 results J/Ψ peak (M = 3.09 GeV) c c Color Screening 12/16/2003 PHENIX Focus, K. Ozawa 13

J/Ψ Results in Run2 40-90 % central N coll = 45 Au+Au J/Ψ e + e at s NN = 200 GeV nucl-ex/0305030; accepted for PRC 20-40 % central N coll = 296 0-20 % central N coll = 779 normal nuclear absorption SPS NA50 normalized to p+p point 12/16/2003 PHENIX Focus, K. Ozawa 14

Low mass e + e - pair Chiral Symmetry Restoration Mass, width of ρ, ω, φ to e+e- Thermal Radiation of Hot Gas Prompt γ * to e+e- Unlike-sign Pair mass 220 200 180 160 140 120 100 80 60 Y. Tsuchimoto 40 20 ω Could be ρ HmassERT2 Entries 9612 Mean 0.6634 RMS 0.5068 0 0.6 0.7 0.8 0.9 1 1.1 1.2 2 e + e - invriant mass [GeV/c ] φ We did not yet get significant results in AuAu. NEED more statistics Recently, we have an indication of peaks in dau data. 12/16/2003 PHENIX Focus, K. Ozawa 15

How to analyze data? Purpose of this section Be familiar with electron ID parameters Calibration 10 2 ADC histogram Number of photo-electrons of each PMT Timing of each PMT 10 1 Mirror alignment 0 200 400 600 800 1000 ADC Value Yield adc6 10 5 10 4 10 3 1 p.e. adc6 Nent = 744153 Mean = -0.7376 RMS = 19.05 Before After Correlation of RICH T0 and BBC T0 12/16/2003 PHENIX Focus, K. Ozawa 16

How to identify electrons? Main parameters in RICH Distance between ring center and track projection (disp) Number of hit PMT in a region (n0) Number of photo-electron in a region (npe0) Ring shape (chi2/npe0) 1. According to the track information, projection point is calculated. 2. Find PMT hits near projection point in the region (3.4 cm < r < 8.4 cm) Numbers come from position resolution of PMT hits. 3. Above parameters are calculated using projection point and PMT hit information 12/16/2003 PHENIX Focus, K. Ozawa 17

Track-Ring association Distance between projected track and ring center (disp) Ring center is calculated weighted mean position of hit PMTs. R center = (Σ i n.p.e i * R i )/ Σ i n.p.e i Also, npe0 = Σ i n.p.e i Number of hit PMTs in the region (n0) disp n0 Distance between R center and hit PMT position 12/16/2003 PHENIX Focus, K. Ozawa 18

Ring shape Difference from expected ring shape are evaluated using the parameter below. chi2 = Σ i ((R i R 0 ) 2 * n.p.e i )/ Σ i n.p.e i R 0 = 5.9 cm Expected ring radius Also, npe0 = Σ i n.p.e i EID Efficiency is evaluated using both simulation and data. Effiency Calculation using conversion peak by S. Lebedev chi2/npe0 12/16/2003 PHENIX Focus, K. Ozawa 19

How good it is. Apply RICH cut All Charged particle Energy / momentum For electron, it should be 1. RICH cut suppress back ground by about factor 100. BG Energy / Momentum RICH works well. We can continue making progress in QGP physics using electron measurements 12/16/2003 PHENIX Focus, K. Ozawa 20

Summary RICH is a large detector and has very large gas volume to identify electrons using cherenkov lights. RICH is successfully constructed and operated without major problems. Electron identification is an essential issue to investigate QGP physics experimentally. Electron identification parameters of RICH are based on the charge information and the ring shape. I hope you are interested in these measurements and RICH operations. 12/16/2003 PHENIX Focus, K. Ozawa 21

Back Up from the last year 12/16/2003 PHENIX Focus, K. Ozawa 22

Look for the RICH in PHENIX Detector System View From Beam View From Top This, this!, this!!, and this!!! Central Arms Coverage (E&W) -0.35< y < 0.35, 30 o < φ < 120 o 12/16/2003 PHENIX Focus, K. Ozawa 23

RICH PMT Hamamatsu H3171S Cathode Diameter: 25 mm Tube Diameter: 29 mm Cathode: Bialkali Gain: > 10 7 Operation Voltage: - 1400 ~ -1800 V Dark current: < 100 na at Gain=10 7 Cathode Luminous: >70 (ma/lm) Blue Sensitivity: > 9(mA/lm) Quantum efficiency: >19% at 300 nm >5 % at 200 nm Rise Time: < 2.5ns Transit Time Spread: < 750ps Total number of PMTs in RICH: 5120 Each PMT is housed in a magnetic shielding case First 900 PMTs: Soft iron and mu-metal Other 4220 PMTs: FERROPERM (NKK) A Winstone cone shaped conical mirror is attached to each PMT to collect Cherenkov light Entrance: 50 mm, Exit: 25 mm, Cut off: 30 12/16/2003 PHENIX Focus, K. Ozawa 24 with FERROPERM (by NKK) Magnetic Shielding Case design

Gas Vessel Two RICH detectors One for each arm Weight: 7250 kg / arm Gas volume: 40 m 3 / arm Radiator length: 0.9-1.5 m Mirror system Radius : 403 cm Surface area: 20 m 2 / arm Photon detector 2560 PMTs/arm Radiation length CO 2 : 0.41% Windows: 0.2% Mirror panels: 0.53% Mirror support: 1.0% Total: 2.14% The vessels are designed and fabricated at Florida State University. 12/16/2003 PHENIX Focus, K. Ozawa 25

RICH Mirror Segmented spherical mirror Reflection surface Aluminum made Mirror mounts are adjusted so that all optical targets are within 0.25 mm of the designed spherical surface. graphite fiber epoxy Mirror support structure graphite fiber, Delrin Mirror, mirror, mirror Design of 3 points mirror mounts Mirror panels are mounted by adjustable 3 point mounts on the frame bars 4 ply graphite-epoxy (0.7 mm thick) Gel-coat (0.05 mm thick) Rohacell foam core (1.25 cm thick) Structure of the mirror 12/16/2003 PHENIX Focus, K. Ozawa 26 Completed mirror array of the first RICH

RICH (mirror alignment) After mirrors are installed, the RICH vessel is rotated up in the same orientation as on PHENIX carriage Positions of optical targets placed on mirror surface were surveyed with a computerized theodolite system (MANCAT). BNL survey crew were measuring the optical targets on the mirror during the mirror alignment. Alignment calibration (Once in RUN) Accumulate all the hit PMTs around tracks for totally 56 mirrors 14(mirrors)*2(side)*2(arm) Adjust mirror positions so that ring centers match projected points of tracks 12/16/2003 PHENIX Focus, K. Ozawa 27

Front End Electronics (FEE) Readout Signals from 5120 PMTs: Zero 10 Photon Detection: 0pC 160pC (Signal Preceded by Pre-Amp(x10) ) Time Resolution of 200 ps (For Background Rejection) Very fast Operation (In old days) 9.6 MHz RHIC Beam Clock 25KHz Average Trigger Frequency Transfer to Data Collection Module (DCM) Data Link using G-LINK Compactness Processes 640 PMT Signals per Crate Conceptual Design of RICH FEE Pre Amp. 12/16/2003 PHENIX Focus, K. Ozawa 28 PMT Timing & Control Signal through Optical Fiber Optical Fiber to DAQ Optical Fiber to Local LVL1 Integrator G-LINK Controller Module G-LINK CFD Int-R chip Stop Signal from Beam Clock Readout Module G-LINK Trigger Module DSU AMU/ADC Module VGA TAC Transfer Go Read Add. LVL1 Comp. BTS FIFO FIFO AMU/ADC chip AMU AMU ALM Charge Timing ADC ADC Write Add. Trigger Sum Source Synchronous Burst Transfer Control Fixed Voltage ADC RICH FEE Backplane

RICH-FEE Crate! 9U VME Dimensions One Controller Module Two Trigger Modules Two Readout Modules Ten Analog Modules Controller Module Heap Management of Analog Memory Unit (AMU) Controls FEE synchronous to Master Timing System Controls Burst Transfer Generate AMU Write / TAC Stop Timing Slow Serial Control using ARCNET Readout Module Transferring Data to PHENIX-DCM using G-LINK at the maximum speed of 800 Mbps G-LINK Transfer asynchronous to BUS Transfer inside RICH-FEE using four FIFOs (Depth: 9 events) DSU/ALM 12/16/2003 PHENIX Focus, K. Ozawa 29 K2 BTS G-Link Transmitter Phase Shifter ROC Readout FIFO

Analog Processing (AMU/ADC) Module 64 Inputs, 64 Charge, 64 Timing and 16 Trigger Sum (4 PMT Sum) Outputs/Board Burst Transfer to Readout Module in 20-40MHz Serial Controllable ASICs on Board 8 RICH Chips (8 Inputs, 8 Charge and Timing, and 4 Trigger Sum, each) 4 AMU/ADC Chips(32 inputs, outputs, each: Random accessible analog memory+adc) Each Analog Sum is summed over 5 boards in backplane, enabling RICH to construct the 4x5 PMT signal sums (trigger tile) which capture rings. LVL-1 Module Accept 16 Trigger current sum inputs from 5 AMU/ADC boards 4*5 PMT sum is already made in the backplane Convert current signal to voltage signal Convert Digital signal to Digital data using FADC Compare the digitized data with threshold value Transfer trigger information to ERT Crate via G-Link AMU/ADC Burst Controller 12/16/2003 PHENIX Focus, K. Ozawa 30 AMU/ADC Chip Integrator+TAC (RICH) Chip