How To Use An Ionsonic Microscope
|
|
- Andra Norman
- 3 years ago
- Views:
Transcription
1 Sample Analysis Design Element2 - Basic Software Concepts
2
3
4 Scan Modes Magnetic Scan (BScan): the electric field is kept constant and the magnetic field is varied as a function of time the BScan is suitable for scanning large, continuous mass ranges to obtain a complete spectrum from an unknown sample. for repeated scanning, a fast flight-back follows each scan depending on the (mass) distance for the flight-back, a settling time for the magnet must be allowed the settling time takes into account the time needed for the magnet to recover from the fast flight-back of each cycle this scan mode is also used for Mass Calibration in order to account for the non-linear behavior of the magnet
5 Scan Modes Electric Scan (EScan): the magnetic field is kept constant and scanning is performed electrically by varying the accelerating voltage and the ESA high voltage this scan mode is the fastest scan the EScan starts with setting the magnet to a mass at the lower end of the Mass Range the available mass range for the electric scan depends on the magnet mass; it ranges from -6% to +30% of the magnet mass
6 Scan Modes EScan advantages: fast scans can be conducted over the detectable mass range without huge energy transfer in the magnet = this results in settling times that do not have to be observed even when performing the fastest repeated scans thus possible to scan the mass ranges of the isotopic pattern and to skip the ranges of no interest possible to carry out replicate measurements in quick succession because of the low energy transfer the advantages of EScan make it the preferred and default scan mode
7
8
9 Integration Window (%): Expressed as a percentage of the peak width, is used to calculate peak intensity. A value of 100% means that the intensity will be calculated from samples, measured in a window of ± ½ peak width of peak center Peak Search Window (%): This specifies the mass window, where the software performs a search (calculation) for the peak center. For example, a value of 100% means that all samples are used in a window of ± ½ peak width of the accurate mass as specified during the elements/isotope selection.
10 Samples per Peak In order to establish a minimum level of precision, the ion signal (peak) must be measured several times during the scan
11 Samples per Peak Recommended values for Samples per Peak as a function of the mode of resolution: -10 samples for low resolution measurements - 20 samples for medium resolution measurements - 30 samples for high resolution measurements
12 Detection Modes
13 Detector Modes Counting Mode: is a digital measurement (counting) and counts events instead of ion signal height it is therefore very sensitive and useful especially for the detection of low signals (concentrations). during acquisition, the number of occurrences is used to generate the intensity information that is stored in a data file this mode of operation can be used in the detection range from 0 to 5 x 10 6 counts per second (cps)
14 Detection Modes Analog Mode: is a standard detection mode each time an ion signal exceeds a certain threshold, the height above the threshold delivers the intensity information (that is stored in a data file) the detection range is between 10 4 and 10 8 cps
15 Detection Modes Both Mode: the analog and the counting signals are monitored by the hardware continuously should the ion signal exceed the security threshold ( trip ) of the ion counter (5 x 10 6 cps), then the protection device disables the counting part until the intensities are below the trip level (if applicable) Note a cross calibration between modes is done automatically
16 Element2 Software Concepts MASS CALIBRATION
17 Mass Calibration The expectation of an ICP-MS user is to see the exact information about peaks, mass numbers, etc. when looking at the computer screen Unfortunately, the computer hardware has no idea about mass and intensity of ions or peaks in a mass spectra
18 Mass Calibration The computer knows DAC (Digital-to-Analog Converter) steps for setting the magnetic field of the instrument and the ADC steps (Analog-to- Digital Converter) for a received intensity The Mass Calibration program translates and adjusts the information available by the computer hardware into the information an ICP- MS user really needs; i.e. mass numbers and intensities for single ions and isotopic patterns
19 Mass Calibration The computer translates DAC values into mass numbers. The DAC values are used for setting the strength of the magnetic field, which modifies the direction of the ions. The hardware is referred to as Magnet DAC or MDAC The actual translation table, the Mass Calibration Table, is stored on the computer s disk in the data directory as <name>.mcl
20 Mass Calibration
21 Mass Calibration
22 Mass Calibration
Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM. Technical Overview.
Strategies for Developing Optimal Synchronous SIM-Scan Acquisition Methods AutoSIM/Scan Setup and Rapid SIM Technical Overview Introduction The 5975A and B series mass selective detectors (MSDs) provide
More informationStart Up. On the right screen, click on the following icon in order to launch the program for EDS analysis.
Start Up On the right screen, click on the following icon in order to launch the program for EDS analysis. You must start up SEM application before starting EDS application. Don t forget to switch off
More informationMicromass LCT User s Guide
Micromass LCT User s Guide 1) Log on to MassLynx with your username & password. 2) After you have logged in, the MassLynx software will automatically run. 3) After MassLynx has come up, open your project
More informationSetting up a Quantitative Analysis MS ChemStation
Setting up a Quantitative Analysis MS ChemStation Getting Ready 1. Use the tutorial section "Quant Reports" on the MSD Reference Collection CD-ROM that came with your ChemStation software. 2. Know what
More informationChapter 6: From Digital-to-Analog and Back Again
Chapter 6: From Digital-to-Analog and Back Again Overview Often the information you want to capture in an experiment originates in the laboratory as an analog voltage or a current. Sometimes you want to
More informationTuning & Mass Calibration
Tuning & Mass Calibration 1 1 The Sample List Sample List Name Project Name 2 The sample list is the top level screen in the TurboMass Gold Software. Data storage is set up in PROJECT files and within
More informationIn-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates
In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates Using the Explore Workflow on the AB SCIEX TripleTOF 5600 System A major challenge in proteomics
More informationThe accurate calibration of all detectors is crucial for the subsequent data
Chapter 4 Calibration The accurate calibration of all detectors is crucial for the subsequent data analysis. The stability of the gain and offset for energy and time calibration of all detectors involved
More informationFunctional Data Analysis of MALDI TOF Protein Spectra
Functional Data Analysis of MALDI TOF Protein Spectra Dean Billheimer dean.billheimer@vanderbilt.edu. Department of Biostatistics Vanderbilt University Vanderbilt Ingram Cancer Center FDA for MALDI TOF
More informationDigital to Analog and Analog to Digital Conversion
Real world (lab) is Computer (binary) is digital Digital to Analog and Analog to Digital Conversion V t V t D/A or DAC and A/D or ADC D/A Conversion Computer DAC A/D Conversion Computer DAC Digital to
More informationPesticide Analysis by Mass Spectrometry
Pesticide Analysis by Mass Spectrometry Purpose: The purpose of this assignment is to introduce concepts of mass spectrometry (MS) as they pertain to the qualitative and quantitative analysis of organochlorine
More informationHow To Analyze Plasma With An Inductively Coupled Plasma Mass Spectrometer
What is ICP-MS? and more importantly, what can it do? Inductively Coupled Plasma Mass Spectrometry or ICP-MS is an analytical technique used for elemental determinations. The technique was commercially
More informationMars Atmosphere and Volatile EvolutioN (MAVEN) Mission
Mars Atmosphere and Volatile EvolutioN (MAVEN) Mission MAVEN Science Community Workshop December 2, 2012 Particles and Fields Package Solar Energetic Particle Instrument (SEP) Davin Larson and the SEP
More informationAMD Analysis & Technology AG
AMD Analysis & Technology AG Application Note 120419 Author: Karl-Heinz Maurer APCI-MS Trace Analysis of volatile organic compounds in ambient air A) Introduction Trace analysis of volatile organic compounds
More informationChoices, choices, choices... Which sequence database? Which modifications? What mass tolerance?
Optimization 1 Choices, choices, choices... Which sequence database? Which modifications? What mass tolerance? Where to begin? 2 Sequence Databases Swiss-prot MSDB, NCBI nr dbest Species specific ORFS
More informationCopyright 2007 Casa Software Ltd. www.casaxps.com. ToF Mass Calibration
ToF Mass Calibration Essentially, the relationship between the mass m of an ion and the time taken for the ion of a given charge to travel a fixed distance is quadratic in the flight time t. For an ideal
More informationThermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software
Thermo Scientific GC-MS Data Acquisition Instructions for Cerno Bioscience MassWorks Software Mark Belmont and Alexander N. Semyonov, Thermo Fisher Scientific, Austin, TX, USA Ming Gu, Cerno Bioscience,
More informationDAC Digital To Analog Converter
DAC Digital To Analog Converter DAC Digital To Analog Converter Highlights XMC4000 provides two digital to analog converters. Each can output one analog value. Additional multiple analog waves can be generated
More informationSignal to Noise Instrumental Excel Assignment
Signal to Noise Instrumental Excel Assignment Instrumental methods, as all techniques involved in physical measurements, are limited by both the precision and accuracy. The precision and accuracy of a
More informationMRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics
MRMPilot Software: Accelerating MRM Assay Development for Targeted Quantitative Proteomics With Unique QTRAP and TripleTOF 5600 System Technology Targeted peptide quantification is a rapidly growing application
More informationShimadzu UV-VIS User s Guide
Shimadzu UV-VIS User s Guide 1) Push the F4 button on the UV-VIS instrument keypad. This will enable PC control. Push the F4 Button 2) Log into the UV-VIS software with your username and password. 3) After
More informationThe modular concept of the MPA-3 system is designed to enable easy accommodation to a huge variety of experimental requirements.
HARDWARE DESCRIPTION The modular concept of the MPA-3 system is designed to enable easy accommodation to a huge variety of experimental requirements. BASE MODULE GO LINE Digital I/O 8 Analog Out AUX 1
More informationA PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION
35'th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting San Diego, December 2-4, 2003 A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION Józef Kalisz and Ryszard Szplet
More informationCHAPTER D1 ION OPTICS OF MAGNETIC/ELECTRIC SECTOR MS
Back to Basics Section D: Ion Optics CHAPTER D1 ION OPTICS OF MAGNETIC/ELECTRIC SECTOR MS TABLE OF CONTENTS QuickGuide...369 Summary...369 Preamble...371 MassAnalysisofIons...371 MagneticSector...371 ElectrostaticAnalyser(ElectricSector)...375
More informationLaboratory Technologies, Inc. Multi-Wiper. Time Saving Multiple Detector Wipe Counter
Laboratory Technologies, Inc. Multi-Wiper Time Saving Multiple Detector Wipe Counter Features Wipe test sets In-vitro tests Patient library Isotope library AutoSpect efficiency correction Advanced 4096-channel
More information13C NMR Spectroscopy
13 C NMR Spectroscopy Introduction Nuclear magnetic resonance spectroscopy (NMR) is the most powerful tool available for structural determination. A nucleus with an odd number of protons, an odd number
More informationAlignment and Preprocessing for Data Analysis
Alignment and Preprocessing for Data Analysis Preprocessing tools for chromatography Basics of alignment GC FID (D) data and issues PCA F Ratios GC MS (D) data and issues PCA F Ratios PARAFAC Piecewise
More informationStudents Manual for the Exam. General Engineering and Electrical Civil Engineering Discipline
Students Manual for the Exam General Engineering and Electrical Civil Engineering Discipline -- October March 2014 2013 -- COPYRIGHT NOTICE COPYRIGHTS 2013 NATIONAL CENTER FOR ASSESSMENT IN HIGHER EDUCATION
More information0 10 20 30 40 50 60 70 m/z
Mass spectrum for the ionization of acetone MS of Acetone + Relative Abundance CH 3 H 3 C O + M 15 (loss of methyl) + O H 3 C CH 3 43 58 0 10 20 30 40 50 60 70 m/z It is difficult to identify the ions
More informationSimultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF
Simultaneous qualitative and quantitative analysis using the Agilent 654 Accurate-Mass Q-TOF Technical Overview Authors Pat Perkins Anabel Fandino Lester Taylor Agilent Technologies, Inc. Santa Clara,
More informationMH - Gesellschaft für Hardware/Software mbh
E.d.a.s.VX Data acquisition on board road and track vehicles The E.d.a.s.VX System is designed for portable applications running on 12 Volts DC, and is capable of measuring at selectable rates up to 30,000,000
More informationAn example: helium isotopes. An example: helium isotopes. Limits to Detection/Measurement. Lecture 14 Measurements II: Mass spectrometry
Limits to Detection/Measurement Ionization is fundamentally a Probabilistic Process Just like radioactive decay So is transmission through the analyzer There is an intrinsic statistical uncertainty Proportional
More information泛 用 蛋 白 質 體 學 之 質 譜 儀 資 料 分 析 平 台 的 建 立 與 應 用 Universal Mass Spectrometry Data Analysis Platform for Quantitative and Qualitative Proteomics
泛 用 蛋 白 質 體 學 之 質 譜 儀 資 料 分 析 平 台 的 建 立 與 應 用 Universal Mass Spectrometry Data Analysis Platform for Quantitative and Qualitative Proteomics 2014 Training Course Wei-Hung Chang ( 張 瑋 宏 ) ABRC, Academia
More informationSample Analysis Design Step 2 Calibration/Standard Preparation Choice of calibration method dependent upon several factors:
Step 2 Calibration/Standard Preparation Choice of calibration method dependent upon several factors: 1. potential matrix effects 2. number of samples 3. consistency of matrix across samples Step 2 Calibration/Standard
More informationSpecifications. MassHunter WorkStation for Agilent 7700 Series ICP-MS. Specifications: MassHunter Workstation (G7211A) for the Agilent 7700 Series
Specifications MassHunter WorkStation for Agilent 7700 Series ICP-MS Specifications: MassHunter Workstation (G7211A) for the Agilent 7700 Series The ICP-MS MassHunter Workstation for the Agilent 7700 Series
More informationMoving Magnet Actuator MI FFA series
Moving Magnet Actuator MI FFA series The moving magnet MI-FFA series actuators are a line of actuators designed to be a true alternative for pneumatic cylinders. The actuators incorporate an ISO 6432 interface
More informationDescription: Multiparameter System (4 or 8 channels)
Model MPA4, 8 ch acquisition system with 6 ns time tagging The MPA4 is a Multiparameter Data Acquisition System Description: Multiparameter System (4 or 8 channels) ADC Settings and Presets Dialog The
More information3D SCANNERTM. 3D Scanning Comes Full Circle. s u n. Your Most Valuable QA and Dosimetry Tools A / B / C. The 3D SCANNER Advantage
3D SCANNERTM 3D Scanning Comes Full Circle Relative 3D Dosimetry offering the easiest setup, most objectivity, and best consistency available The 3D SCANNER Advantage Advanced Design Ring and diameter
More informationLC-MS/MS for Chromatographers
LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS, with an emphasis on the analysis of drugs in biological matrices LC-MS/MS for Chromatographers An introduction to the use of LC-MS/MS,
More informationUnique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS
Unique Software Tools to Enable Quick Screening and Identification of Residues and Contaminants in Food Samples using Accurate Mass LC-MS/MS Using PeakView Software with the XIC Manager to Get the Answers
More informationSpectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs
Spectroscopy Biogeochemical Methods OCN 633 Rebecca Briggs Definitions of Spectrometry Defined by the method used to prepare the sample 1. Optical spectrometry Elements are converted to gaseous atoms or
More informationQ-AMS Data Acquisition (DAQ) Software
Q-AMS Data Acquisition (DAQ) Software 6 th AMS Users Meeting University of Minnesota, Minnesota Sep, 2006 Update on Q-AMS Data Acquisition Software Status Current Software Version: V 4.6 Software versions
More informationMPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card
Machinery Protection Card Type FEATURES Continuous on-line Machinery Protection Card Real-time measurement and monitoring using state-of-the-art DSP techniques Fully VME-compatible slave interface Fully
More informationQuick Start Guide Chromeleon 7.2
Chromeleon 7.2 7229.0004 Revision 1.0 July 2013 Table of Contents 1 Introduction... 1 1.1 About this Document... 1 1.2 Other Documentation... 2 2 Using Chromeleon... 3 2.1 Overview... 3 2.2 Starting Chromeleon...
More informationBackground Information
1 Gas Chromatography/Mass Spectroscopy (GC/MS/MS) Background Information Instructions for the Operation of the Varian CP-3800 Gas Chromatograph/ Varian Saturn 2200 GC/MS/MS See the Cary Eclipse Software
More informationF321 THE STRUCTURE OF ATOMS. ATOMS Atoms consist of a number of fundamental particles, the most important are... in the nucleus of an atom
Atomic Structure F32 TE STRUCTURE OF ATOMS ATOMS Atoms consist of a number of fundamental particles, the most important are... Mass / kg Charge / C Relative mass Relative Charge PROTON NEUTRON ELECTRON
More informationAccurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances
Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances TripleTOF 5600 + LC/MS/MS System with MasterView Software Adrian M. Taylor AB Sciex Concord, Ontario (Canada) Overview
More informationAnalyst 1.6 Software. Software Reference Guide
Analyst 1.6 Software Software Reference Guide Release Date: August 2011 This document is provided to customers who have purchased AB SCIEX equipment to use in the operation of such AB SCIEX equipment.
More informationWaters Core Chromatography Training (2 Days)
2015 Page 2 Waters Core Chromatography Training (2 Days) The learning objective of this two day course is to teach the user core chromatography, system and software fundamentals in an outcomes based approach.
More informationLongitudinal Relaxation Time (T 1 ) Measurement for 1 H on VnmrJ2.2D (use on Ra, Mut, and Isis)
Longitudinal Relaxation Time (T 1 ) Measurement for 1 H on VnmrJ2.2D (use on Ra, Mut, and Isis) Knowledge of the T 1 's of a molecule is important in the setup of many 1D and 2D experiments, in which the
More informationMassHunter for Agilent GC/MS & GC/MS/MS
MassHunter for Agilent GC/MS & GC/MS/MS Next Generation Data Analysis Software Presented by : Terry Harper GC/MS Product Specialist 1 Outline of Topics Topic 1: Introduction to MassHunter Topic 2: Data
More informationAccurate calibration of on-line Time of Flight Mass Spectrometer (TOF-MS) for high molecular weight combustion product analysis
Accurate calibration of on-line Time of Flight Mass Spectrometer (TOF-MS) for high molecular weight combustion product analysis B. Apicella*, M. Passaro**, X. Wang***, N. Spinelli**** mariadellarcopassaro@gmail.com
More informationI2C PRESSURE MONITORING THROUGH USB PROTOCOL.
I2C PRESSURE MONITORING THROUGH USB PROTOCOL. Product Details: To eradicate human error while taking readings such as upper precision or lower precision Embedded with JAVA Application: Technology Used:
More informationTutorial 9: SWATH data analysis in Skyline
Tutorial 9: SWATH data analysis in Skyline In this tutorial we will learn how to perform targeted post-acquisition analysis for protein identification and quantitation using a data-independent dataset
More informationHow To Build An Amd Quas 3 Ar Mass Spectrometer
Classical and special AMD Magnetic Sector mass spectrometers (extracted from power point presentations) High Resolution Mass Spectromter AMD 402/403 S 6 High Resolution Mass Spectrometer AMD 604 S 8 Version
More informationX- and Gamma Ray Imaging Systems based on CdTe-CMOS Detector Technology
X- and Gamma Ray Imaging Systems based on dte-mos Detector Technology Konstantinos Spartiotis, Ray Durrant, nssi Leppänen, Henrik Lohman, Olli Männistö, Tuomas Pantsar, Jouni Pyyhtiä, Tom Schulman, Oy
More informationVADC Versatile Analog to Digital Converter. XMC Microcontrollers August 2014
Versatile Analog to Digital Converter XMC Microcontrollers August 2014 TRIGGER AND GATING EVENT GENERATION Versatile Analog to Digital Converter Highlights QUEUE SOURCE SCAN SOURCE ARBITRATION BCKGND SOURCE
More informationAudit Report and Requirements of Mantid Software from the Molecular Spectroscopy Group (2013)
Audit Report and Requirements of Mantid Software from the Molecular Spectroscopy Group 1. Current Status (2013) The current status of the data analysis software, Mantid, corresponding to each group instrument
More informationMeasuring Resistance Using Digital I/O
Measuring Resistance Using Digital I/O Using a Microcontroller for Measuring Resistance Without using an ADC. Copyright 2011 John Main http://www.best-microcontroller-projects.com Page 1 of 10 Table of
More informationAnalog/Digital Conversion. Analog Signals. Digital Signals. Analog vs. Digital. Interfacing a microprocessor-based system to the real world.
Analog/Digital Conversion Analog Signals Interacing a microprocessor-based system to the real world. continuous range x(t) Analog and digital signals he bridge: Sampling heorem Conversion concepts Conversion
More informationHitachi U-4100 UV-vis-NIR spectrophotometer (341-F)
Hitachi U-4100 UV-vis-NIR spectrophotometer (341-F) Please contact Dr. Amanda Young for training requests and assistance: 979-862-6845, amandayoung@tamu.edu Hardware Our spectrophotometer is made up of
More informationHow To Use A Detector 2
Technical Information TI No. WL 80-62 E January 2003 Detector II the mobile phone among the data collectors Maintenance Products Application Condition-based maintenance Principle of operation Application
More informationAtmel Norway 2005. XMEGA Introduction
Atmel Norway 005 XMEGA Introduction XMEGA XMEGA targets Leadership on Peripheral Performance Leadership in Low Power Consumption Extending AVR market reach XMEGA AVR family 44-100 pin packages 16K 51K
More informationAndroid based Alcohol detection system using Bluetooth technology
For more Project details visit: http://www.projectsof8051.com/android-based-alcohol-detection-system-usingbluetooth-technology/ Code 1435 Project Title Android based Alcohol detection system using Bluetooth
More informationTime-of-Flight Mass Spectrometry
Time-of-Flight Mass Spectrometry Technical Overview Introduction Time-of-flight mass spectrometry (TOF MS) was developed in the late 1940 s, but until the 1990 s its popularity was limited. Recent improvements
More informationTire pressure monitoring
Application Note AN601 Tire pressure monitoring 1 Purpose This document is intended to give hints on how to use the Intersema pressure sensors in a low cost tire pressure monitoring system (TPMS). 2 Introduction
More information3 SOFTWARE AND PROGRAMMING LANGUAGES
3 SOFTWARE AND PROGRAMMING LANGUAGES 3.1 INTRODUCTION In the previous lesson we discussed about the different parts and configurations of computer. It has been mentioned that programs or instructions have
More informationPreface Light Microscopy X-ray Diffraction Methods
Preface xi 1 Light Microscopy 1 1.1 Optical Principles 1 1.1.1 Image Formation 1 1.1.2 Resolution 3 1.1.3 Depth of Field 5 1.1.4 Aberrations 6 1.2 Instrumentation 8 1.2.1 Illumination System 9 1.2.2 Objective
More informationWIRELESS BLACK BOX USING MEMS ACCELEROMETER AND GPS TRACKING FOR ACCIDENTAL MONITORING OF VEHICLES
WIRELESS BLACK BOX USING MEMS ACCELEROMETER AND GPS TRACKING FOR ACCIDENTAL MONITORING OF VEHICLES PROJECT REFERENCE NO. : 37S0430 COLLEGE BRANCH GUIDE : S.G.BALEKUNDRI INSTITUTE OF TECHNOLOGY,BELGAUM
More informationImproving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification
Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification Overview LightSight Software for Metabolite Identification is a complete environment
More informationPC BASED PID TEMPERATURE CONTROLLER
PC BASED PID TEMPERATURE CONTROLLER R. Nisha * and K.N. Madhusoodanan Dept. of Instrumentation, Cochin University of Science and Technology, Cochin 22, India ABSTRACT: A simple and versatile PC based Programmable
More informationSignal, Noise, and Detection Limits in Mass Spectrometry
Signal, Noise, and Detection Limits in Mass Spectrometry Technical Note Chemical Analysis Group Authors Greg Wells, Harry Prest, and Charles William Russ IV, Agilent Technologies, Inc. 2850 Centerville
More informationManual for simulation of EB processing. Software ModeRTL
1 Manual for simulation of EB processing Software ModeRTL How to get results. Software ModeRTL. Software ModeRTL consists of five thematic modules and service blocks. (See Fig.1). Analytic module is intended
More informationResidual Gas Analyzers
Residual Gas Analyzers RGA100/200/300 100 amu, 200 amu and 300 amu systems SRS Residual Gas Analyzers 100, 200 and 300 amu systems Better than 1 amu resolution 6 decades of dynamic range 5 10 14 Torr detection
More informationFinnigan ELEMENT2. High Performance High Resolution ICP-MS
m a s s s p e c t r o m e t r y Finnigan ELEMENT2 High Performance High Resolution ICP-MS Analyze Detect Measure Control Finnigan ELEMENT2 High Performance High Resolution ICP-MS Finnigan ELEMENT2 High
More informationAnalysis of Liquid Samples on the Agilent GC-MS
Analysis of Liquid Samples on the Agilent GC-MS I. Sample Preparation A. Solvent selection. 1. Boiling point. Low boiling solvents (i.e. b.p. < 30 o C) may be problematic. High boiling solvents (b.p. >
More informationMassLynx 4.1 Getting Started Guide
MassLynx 4.1 Getting Started Guide 71500113203/Revision A Copyright Waters Corporation 2005. All rights reserved. Copyright notice 2005 WATERS CORPORATION. PRINTED IN THE UNITED STATES OF AMERICA AND IRELAND.
More informationAppendix 5 Overview of requirements in English
Appendix 5 Overview of requirements in English This document is a translation of Appendix 4 (Bilag 4) section 2. This translation is meant as a service for the bidder and in case of any differences between
More informationAnalyst 1.6 Software. Getting Started Guide
Analyst 1.6 Software Getting Started Guide Release Date: August 2011 This document is provided to customers who have purchased AB SCIEX equipment to use in the operation of such AB SCIEX equipment. This
More informationTransmitter Interface Program
Transmitter Interface Program Operational Manual Version 3.0.4 1 Overview The transmitter interface software allows you to adjust configuration settings of your Max solid state transmitters. The following
More informationAgilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range. Application Note
Agilent AN 1315 Optimizing RF and Microwave Spectrum Analyzer Dynamic Range Application Note Table of Contents 3 3 3 4 4 4 5 6 7 7 7 7 9 10 10 11 11 12 12 13 13 14 15 1. Introduction What is dynamic range?
More informationTRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY
TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY 2 TRACTION NETWORK MONITORING AND PROTECTION SYSTEM Traction network monitoring and protection system,
More informationGammaVision 8. Gamma Spectroscopy Software. Compatible, Efficient, and Defendable Results for Gamma Spectroscopy Applications.
GammaVision 8 Gamma Spectroscopy Software Compatible, Efficient, and Defendable Results for Gamma Spectroscopy Applications. GammaVision is an All-Inclusive gamma spectroscopy application for High and
More informationTime-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software
Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software Technical Brief Introduction The MSO70000 Series Mixed Oscilloscope, when coupled with SignalVu Spectrum
More informationPermissible ambient temperature Operation Storage, transport
The Sitras PRO combined DC protective unit and controller is used in the power supply for DC railways in mass transit and main-line systems up 3,000 V DC. It protects DC switch gear and contact line systems
More informationNuclear Structure. particle relative charge relative mass proton +1 1 atomic mass unit neutron 0 1 atomic mass unit electron -1 negligible mass
Protons, neutrons and electrons Nuclear Structure particle relative charge relative mass proton 1 1 atomic mass unit neutron 0 1 atomic mass unit electron -1 negligible mass Protons and neutrons make up
More informationLogging of RF Power Measurements
Logging of RF Power Measurements By Orwill Hawkins Logging of measurement data is critical for effective trend, drift and Exploring the use of RF event analysis of various processes. For RF power measurements,
More informationA Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015
A Navigation through the Tracefinder Software Structure and Workflow Options Frans Schoutsen Pesticide Symposium Prague 27 April 2015 Kings day in The Netherlands 1 Index Introduction Acquisition, Method
More informationIntroduction. What Can an Offline Desktop Processing Tool Provide for a Chemist?
Increasing Chemist Productivity in an Open-Access Environment Ryan Sasaki, Graham A. McGibbon, Steve Hayward Featuring ACD/Spectrus Processor and Aldrich Library for ACD/Labs Advanced Chemistry Development,
More informationSilicon Seminar. Optolinks and Off Detector Electronics in ATLAS Pixel Detector
Silicon Seminar Optolinks and Off Detector Electronics in ATLAS Pixel Detector Overview Requirements The architecture of the optical links for the ATLAS pixel detector ROD BOC Optoboard Requirements of
More informationAnalyst 1.6.1 Software
MAX cover image size 4.8 inches X 7.8 inches In Body page mode, draw a graphic frame to match this section and then go to the next step. Delete this text from the Front Cover Master page. View>Master Pages,
More informationTemperature Sensors. Resistance Temperature Detectors (RTDs) Thermistors IC Temperature Sensors
Temperature Sensors Resistance Temperature Detectors (RTDs) Thermistors IC Temperature Sensors Drew Gilliam GE/MfgE 330: Introduction to Mechatronics 03.19.2003 Introduction There are a wide variety of
More informationData Analysis Software
Data Analysis Software Compatible with all Race Technology products Fully integrated video support Accurate track maps Graphs generated with a single mouse click for fast analysis Automatically splits
More informationMass spectrometry. What are the principles behind MS? What do all MS instruments have in common?
Mass spectrometry What are the principles behind MS? What do all MS instruments have in common? What are the different types of MS? Lecture outline: 1) Introduction to mass spectrometry 2) sample introduction
More informationCHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging
Physics of Medical X-Ray Imaging (1) Chapter 3 CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY 3.1 Basic Concepts of Digital Imaging Unlike conventional radiography that generates images on film through
More informationTeaching the Importance of Data Correlation in Engineering Technology
Session 3549 Teaching the Importance of Data Correlation in Engineering Technology Michael R. Warren, Dana M. Burnett, Jay R. Porter, and Rainer J. Fink Texas A&M University Abstract To meet the needs
More informationMATRIX TECHNICAL NOTES
200 WOOD AVENUE, MIDDLESEX, NJ 08846 PHONE (732) 469-9510 FAX (732) 469-0418 MATRIX TECHNICAL NOTES MTN-107 TEST SETUP FOR THE MEASUREMENT OF X-MOD, CTB, AND CSO USING A MEAN SQUARE CIRCUIT AS A DETECTOR
More informationMetabolomics Software Tools. Xiuxia Du, Paul Benton, Stephen Barnes
Metabolomics Software Tools Xiuxia Du, Paul Benton, Stephen Barnes Outline 2 Introduction Software Tools for LC-MS metabolomics Software Tools for GC-MS metabolomics Software Tools for Statistical Analysis
More informationBasic RTD Measurements. Basics of Resistance Temperature Detectors
Basic RTD Measurements Basics of Resistance Temperature Detectors Platinum RTD resistances range from about 10 O for a birdcage configuration to 10k O for a film type, but the most common is 100 O at 0
More informationCOMPUTER HARDWARE. Input- Output and Communication Memory Systems
COMPUTER HARDWARE Input- Output and Communication Memory Systems Computer I/O I/O devices commonly found in Computer systems Keyboards Displays Printers Magnetic Drives Compact disk read only memory (CD-ROM)
More information