Engineering design experience of an undergraduate thermodynamics course



Similar documents
An analysis of a thermal power plant working on a Rankine cycle: A theoretical investigation

How To Calculate The Performance Of A Refrigerator And Heat Pump

Sheet 5:Chapter 5 5 1C Name four physical quantities that are conserved and two quantities that are not conserved during a process.

APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

Lesson. 11 Vapour Compression Refrigeration Systems: Performance Aspects And Cycle Modifications. Version 1 ME, IIT Kharagpur 1

Mohan Chandrasekharan #1

PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.

UNIT 2 REFRIGERATION CYCLE

GEOTHERMAL POWER PLANT CYCLES AND MAIN COMPONENTS

FEASIBILITY OF A BRAYTON CYCLE AUTOMOTIVE AIR CONDITIONING SYSTEM

Thermodynamics - Example Problems Problems and Solutions

REFRIGERATION (& HEAT PUMPS)

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

Energy Analysis and Comparison of Advanced Vapour Compression Heat Pump Arrangements

Jet Propulsion. Lecture-2. Ujjwal K Saha, Ph.D. Department of Mechanical Engineering Indian Institute of Technology Guwahati 1

Increasing the evaporation temperature with the help of an internal heat exchanger

Chapter 10: Refrigeration Cycles

FUNDAMENTALS OF ENGINEERING THERMODYNAMICS

DEVELOPMENT OF A TWIN SCREW EXPRESSOR AS A THROTTLE VALVE REPLACEMENT FOR WATER-COOLED CHILLERS

Open Cycle Refrigeration System

Condensers & Evaporator Chapter 5

Analysis of Ammonia Water (NH3-H2O) Vapor Absorption Refrigeration System based on First Law of Thermodynamics

THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A

Energy Procedia Energy 00 Procedia (2011) (2012) 56 65

APPLIED THERMODYNAMICS. TUTORIAL No.3 GAS TURBINE POWER CYCLES. Revise gas expansions in turbines. Study the Joule cycle with friction.

Chapter 2 P-H Diagram Refrigeration Cycle Analysis & Refrigerant Flow Diagram

High Pressure Ammonia Systems New Opportunities

DRAFT. Appendix C.2 - Air Conditioning Thermodynamics 1

The Second Law of Thermodynamics

CHAPTER 7 THE SECOND LAW OF THERMODYNAMICS. Blank

Low GWP Replacements for R404A in Commercial Refrigeration Applications

The Second Law of Thermodynamics

Analytical Study of Vapour Compression Refrigeration System Using Diffuser and Subcooling

Optimal operation of simple refrigeration cycles Part I: Degrees of freedom and optimality of sub-cooling

ME 201 Thermodynamics

C H A P T E R T W O. Fundamentals of Steam Power

Optimal operation of an Ammonia refrigeration cycle

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

DET: Mechanical Engineering Thermofluids (Higher)

Purpose of Refrigeration

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine

Warm medium, T H T T H T L. s Cold medium, T L

Chapter 3.4: HVAC & Refrigeration System

COURSE TITLE : REFRIGERATION AND AIR CONDITIONING COURSE CODE : 4029 COURSECATEGORY : A PERIODS/WEEK : 5 PERIODS/SEMESTER : 90 CREDITS : 4 OBJECTIVES

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

Boiler Calculations. Helsinki University of Technology Department of Mechanical Engineering. Sebastian Teir, Antto Kulla

Efficiency of Hydrogen Liquefaction Plants

2B.1 Chilled-Water Return (and Supply) Temperature B.3 Cooling-Water Supply Temperature / Flow

CO MPa (abs) 20 C

Development of a model for the simulation of Organic Rankine Cycles based on group contribution techniques

Fundamentals of THERMAL-FLUID SCIENCES

Theoretical Study on Separate Sensible and Latent Cooling Air-Conditioning System

AIR REVERSING R744 AIR CONDITIONING SYSTEM

A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures

2004 Standard For Performance Rating Of Positive Displacement Refrigerant Compressors And Compressor Units

Stirling heat engine Internal combustion engine (Otto cycle) Diesel engine Steam engine (Rankine cycle) Kitchen Refrigerator

Diesel Cycle Analysis

Integration of a fin experiment into the undergraduate heat transfer laboratory

Research on the Air Conditioning Water Heater System

TEST REPORT #31. System Drop-in Test of Refrigerant R-32 in Split Air-conditioning System

QUESTIONS THERMODYNAMICS PRACTICE PROBLEMS FOR NON-TECHNICAL MAJORS. Thermodynamic Properties

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

6 18 A steam power plant receives heat from a furnace at a rate of 280 GJ/h. Heat losses to the surrounding air from the steam as it passes through

Ambient Energy Fraction of a Heat Pump

POSSIBILITY FOR MECHANICAL VAPOR RE-COMPRESSRION FOR STEAM BASED DRYING PROCESSES

Design of Cold Storage Structure For Thousand Tonne Potatoes

SAMPLE CHAPTERS UNESCO EOLSS

Advanced Process Integration for Low Grade Heat Recovery

Chapter 17. For the most part, we have limited our consideration so COMPRESSIBLE FLOW. Objectives

AIR CONDITION & REFRIGERATION INSTALLATION & REPAIR

Validation of a vapour compression refrigeration system design model

UNDERSTANDING REFRIGERANT TABLES

Module 5: Combustion Technology. Lecture 34: Calculation of calorific value of fuels

AMMONIA AND CARBON DIOXIDE HEAT PUMPS FOR HEAT RECOVERY IN INDUSTRY

Characteristics of Evaporators

New Trends in the Field of Automobile Air Conditioning

Testing methods applicable to refrigeration components and systems

A basic introduction to steam

42-Volt Electric Air Conditioning System Commissioning and Control For a Class-8 Tractor

A Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of Low Global Warming Potential

HIGH-EFFICIENCY CO 2 HEAT PUMP WATER HEATER SYSTEMS FOR RESIDENTIAL AND NON-RESIDENTIAL BUILDINGS

OPTIMAL DESIGN AND OPERATION OF HELIUM REFRIGERATION SYSTEMS *

8. Heat pumps, heat pipes, cold thermal energy storage

Engineering Recommendation on: Accumulators Revised Issued January 10, 1979 Page 1 of 7

How To Know If A Refrigeration System Is Efficient

How does solar air conditioning work?

ES-7A Thermodynamics HW 1: 2-30, 32, 52, 75, 121, 125; 3-18, 24, 29, 88 Spring 2003 Page 1 of 6

Experimental Analysis of an Automotive Air Conditioning System With Two-Phase Flow Measurements

Fundamentals of Mechanical Refrigeration Systems

Performance Improvement of an Air Conditioning System Using Matrix Heat Exchanger

Chapter 14. At temperatures below the critical temperature, the gas GAS VAPOR MIXTURES AND AIR-CONDITIONING. Objectives

Experimental Analysis of a Variable Capacity Heat Pump System Focusing on the Compressor and Inverter Loss Behavior

A/C refrigerant system, overview

Performance Evaluation of a Heat Pump System for Simultaneous Heating and Cooling

Modelling and Simulation of the Freezing Systems and Heat Pumps Using Unisim Design

Theoretical and Numerical Analysis of Heat Transfer in Pipeline System

Transcription:

World Transactions on Engineering and Technology Education Vol.10, No.1, 2012 2012 WIETE Engineering design experience of an undergraduate thermodynamics course Hosni I. Abu-Mulaweh & Abdulaziz A. Al-Arfaj King Faisal University Al-Ahsa, Kingdom of Saudi Arabia ABSTRACT: One important educational outcome required of any engineering programme, as per ABET 2000 Criteria 3, is the ability of engineering graduates to design a component or a system. Engineering design is an integral part of several mechanical engineering courses throughout the curriculum at King Faisal University (KFU). Presented in this article is an example of engineering design experience in an undergraduate first thermodynamics course. It presents a thermodynamics initial design of a refrigeration system that meets desired needs. Basic thermodynamics principles such as the first and second laws, isentropic efficiency, and coefficient of performance (COP) were employed in the analysis, leading to the initial design of this refrigeration system.this kind of experience serves to enhance the understanding of the various thermodynamics concepts and principles. INTRODUCTION For an engineering curriculum to be successful, it must provide students with the opportunity to be exposed to engineering design. In addition, ABET 2000 Criteria 3 requires that for an engineering programme to be accredited, it must demonstrate that appropriate educational programme outcomes are met. According to these criteria, all undergraduate engineering programmes need to provide for design experience. This fact is stated in outcome c): an ability to design a system, component, or process to meet desired needs [1]. To meet the requirements of the ABET accreditation criteria, the mechanical engineering academic staff at KFU have integrated engineering design throughout the curriculum, spanning freshman, sophomore, junior and senior level courses. Thermodynamics is a very important subject and has long been an essential part of mechanical engineering curricula all over the world. Thermodynamics is encountered in a wide variety of engineering applications where heating, cooling and refrigeration is required. Thermodynamics plays an important role in the design of many devices, such as radiators, heating and air conditioning systems, refrigerators, power plants and many others. Objective Discussed in this article is a design project set for students of Mechanical Engineering at KFU. The objective of this project is to obtain an initial design of a refrigeration system. This project is one of the requirements of the Thermodynamics I class. Thermodynamics I is a mechanical engineering sophomore level course. This project is very comprehensive and requires the understanding of most thermodynamics concepts that were covered in the course in order to obtain a successful design [2-4]. The following is the problem statement of the design project that was given to the students. Problem Statement A refrigeration system is to be designed to maintain the temperature in the range -15 C to -5 C, while the outside temperature varies from 15 C to 25 C. The total thermal load on the storage unit is given as 20 kw. Obtain an initial design for the vapour compression refrigeration system shown in Figure 1. Choose a safe and suitable refrigerant. For safe operation and other factors, such as additional energy transfer, design the system using a safety factor of 1.3. The compressor efficiency could range from 60 to 80 percent. Need to specify or/and determine the temperatures and pressures at the different states and show the cycle with the vapour dome on a temperature entropy (T-s) diagram. Also, need to determine the coefficient of performance value and the mass flow rate of the working fluid. 77

3 Heat Rejection Flow Condenser 2 Thermal Expansion Valve Removed Heat Compressor Energy Input Evaporator 4 1 Figure 1: Vapour compression refrigeration cycle. Background Refrigeration Cycle A basic refrigeration cycle consists of four major components: a compressor, a condenser, a thermal expansion valve and an evaporator [3]. As a refrigerant passes through a cycle containing these four elements, air conditioning occurs. The cycle starts when refrigerant enters the compressor at low pressure, low temperature and in a gaseous form. The refrigerant is compressed by the compressor to a high pressure and temperature gaseous state. The high pressure and temperature gas then enters the condenser. The condenser precipitates the high pressure and temperature gas to a high temperature liquid by transferring heat to a lower temperature medium, usually ambient air. The high temperature liquid then enters the expansion valve where the TX valve allows a portion of the refrigerant to enter the evaporator. In order for the higher temperature fluid to cool, the flow must be limited into the evaporator to keep the pressure low and allow expansion back into the gas phase. Compressor This component is a compression device that requires input of power to increase the pressure of a gas. It cannot operate on liquids or two-phase. Therefore, the working fluid such as the refrigerant must leave the evaporator and enter the compressor at least as saturated vapour. Condenser and Evaporator These devices are heat exchange devices [5][6]. They are used to transfer heat between two different fluids. The evaporator is used to remove heat from the interior of the refrigerator compartment by exchanging heat between the air inside the refrigerator and the refrigerant passing through the tubes of the evaporator. The condenser is used to remove the heat from the refrigerant gained through the evaporator and the compressor. This is done by transferring the heat to the ambient air, which must be at a lower temperature than that of the refrigerant exiting the condenser. Thermal Expansion Valve A thermal expansion valve (TEV) is a component in refrigeration and air conditioning systems that controls the amount of refrigerant flow into the evaporator, thereby, controlling the superheating at the outlet of the evaporator. DESIGN METHODOLOGY Assumptions To obtain an initial design of a refrigeration system as requested by the problem statement, the following assumptions are made: The four components (compressor, condenser, evaporator, thermal expansion valve) of the thermodynamics cycle are modelled as open systems. 78

The four components (devices) operate under steady-state, steady-flow process. The changes in kinetic and potential energies across each device are negligible. Both the compressor and the expansion device are considered adiabatic (i.e. the heat transfer from these devices is negligible). Both the evaporator and the condenser are considered constant pressure devices. Thermodynamics Modelling The basic concept of this design is to use a vapour compression cycle. Utilising the first and second laws of thermodynamics [3] along with the above mentioned assumptions, a thermodynamics model for the refrigeration system can be developed as follows: Compressor: (1) Condenser: (2) Evaporator: (3) Expansion Valve: throttling process (4) Where is the power input to the compressor, is the mass flow of the refrigerant, is the heat absorped by the evaporator, is the heat rejected by the condenser and is the enthalpy. In these relations the number refers to the state of the refrigerant as indicated in Figure 1. The isentropic efficiency of the compressor, η, is defined as the ratio of the isentropic (ideal) work input required to the actual work input required for the same inlet state and the same exit pressure [3]: η = (5) The coefficient of performance (COP) for the refrigeration system is given by [3]: Analysis Refrigerant Selection For an effective system, a refrigerant should be used to ensure necessary thermodynamics properties at the temperatures and conditions the system will be operating at, and to ensure increased efficiency. To determine which refrigerant to use, several factors should be considered. The refrigerant should not be toxic, it should not be flammable at the operating pressures and temperatures, it should be minimally environmentally degrading, and in general, it should not be harmful to humans. Based on an intensive review and search of several refrigerants such as R-12, R-22, R-134a, R-410a, and ammonia, it was found that R-134a is a safe, no toxic refrigerant that is easy to obtain. Thus, it was selected to be the working fluid for this refrigeration system. Design Parameters To ensure that the system will operate over the entire temperature ranges stated in the problem statement, the refrigeration system was designed for the extreme conditions (i.e. -15 o C for the inside and 25 o C for the ambient). On top of that, a safety factor of 1.3 was also used as suggested by the design project statement. The isentropic efficiency of the turbine was selected to be 75%. Design Procedure and Calculations There are several thermodynamics and heat transfer facts that must be satisfied while deciding on the design [7][8]: 1. From basic physics, heat always flows in the direction of decreasing temperature and in order to have heat transfer there must be a temperature difference. Therefore, the temperature of the refrigerant in the evaporator tubes must be less than the air temperature inside the refrigerator and the temperature of the refrigerant at the exit of the condenser is higher than the outside ambient air. (6) 79

To satisfy this, temperature of the refrigerant in the evaporator was selected to be -20 o C (less than -15 o C) and the temperature of the refrigerant at the exit of the condenser was selected to be 40 o C (higher than 25 o C). 2. As mentioned earlier, the compressor operates only on gases (not liquids or two-phase). Therefore, the exit of the evaporator must be at least saturated vapour (x 1 = 1). 3. The exit of the condenser must be at least saturated liquid (x 3 = 0). Based on the above three facts, a thermodynamics model can be constructed and an initial design of a refrigeration system that satisfies the stated requirements can be obtained. RESULTS Detailed calculations were carried out utilising the relations and the thermodynamics model outlined in the above to obtain an initial design of a refrigeration system that meets the stated requirement. Table 1 includes the relevant thermodynamics properties at the inlets and outlets of the four components (devices) that comprise the vapour compression cycle of the refrigeration system. These properties are needed to determine the heat input to the evaporator, the heat rejected from the condenser, the work input to the compressor, the refrigerant mass flow rate and the coefficient of performance of the system. Table 2 is a summary of the initial design values of the refrigeration system that meets the specified requirements. Figure 2 shows the vapour compression cycle of the designed refrigeration system on T-s phase diagram (temperature - entropy phase diagram) along with the vapour dome. Also, the figure shows both the actual and isentropic (ideal) compression of the refrigerant through the compressor. Table 1: Thermodynamics properties at the relevant states. State T P h s ( o C) (KPa) (kj/kg) (kj/kg. K) x 1-20 132.8 238.4 0.94564 1 2s 48 1000 280.55 0.94564 N/A 2a 61.17 1000 294.6 0.98861 N/A 3 40 1000 107.32 0.39189 0 4-20 132.8 107.32 0.4279 0.384 Table 2: Initial design values. (W) 26 (W) 34.46 (W) 8.46 (kg/s) 0.1895 3.07 Figure 2: Vapour compression cycle on T-s phase diagram. 80

CONCLUSIONS AND RECOMMENDATIONS A practical example of an engineering design project in the area of thermodynamics is presented in detail. The project involves an initial design of a refrigeration system based on a vapour compression cycle that meets specified requirements. This type of design project can be used as a measure of students understanding of the various thermodynamics concepts and principles normally covered in the undergraduate first thermodynamics course. Feedback from the students was very positive. REFERENCES 1. ABET Engineering Accreditation Criteria, Criterion 3: Program Outcomes and Assessment, http://www.abet.org. 2. Borgnkke, C. and Sonntag, R.E., Fundamentals of Thermodynamics. (7th Edn), John Whiley & Sons, Inc. (2009). 3. Cengel, Y.A. and Boles, M.A., Thermodynamics - An Engineering Approach. (6th Edn), McGraw- Hill (2008). 4. Moran, M.J. and Shapiro, H.N., Fundamentals of Engineering Thermodynamics. (6th Edn), John Whiley & Sons, Inc. (2008). 5. Bergman, T.L. Lavine, A.S. Incorpera, F.P. and Dewitt, D.P., Fundamentals of Heat and Mass Transfer. (7th Edn), John Whiley & Sons, Inc. (2011). 6. Cengel, Y.A., Heat and Mass Transfer - A Practical Approach. (3rd Edn), John Whiley & Sons, Inc. (2007). 7. Bejan, A., Tsatsaronis, G. and Moran, M.J., Thermal Design & Optimization. John Whiley & Sons, Inc. (1996). 8. Suryanarayana, N.V. and Arici, O., Design and Simulation of Thermal Systems. McGraw-Hill (2002). 81