R.C.C.B. s two-pole LEXIC

Similar documents
NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

The complete range of consumer switchboards and switchgear

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

5SV Residual Current Protective Devices

Three-phase monitoring relay CM-PFE

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

IEC >>> IEC GUIDE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

RM4TG20 three-phase network control relay RM4-T - range V

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Type: DILM32 10(24V50HZ) Article No.:

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Manual motor starter MS116

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Type: DILM9 10(24VDC) Article No.:

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

RY2 miniature industrial relays

ADM1TE 5/30A DIN rail single phase two wire energy meter

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

System pro M compact Miniature Circuit Breaker S 200/S 200 M

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Safety automation solutions

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Type: DILM50(230V50HZ,240V60HZ) Article No.:

SURGE PROTECTIVE DEVICES

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Technicaldata General

MasterINTERFACE 39 Series - Relay interface modules

Manual Motor Starter MS 116 up to 16 A Technical Data

Catalog. Modular DIN rail components Installation contactors

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

38 Series - Relay interface modules A

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

MasterINTERFACE 39 Series - Relay interface modules

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Bimetallic Overload Relay Specifications

48 SERIES Relay interface modules 10 A

38 Series - Relay interface modules A

49 Series - Relay interface modules A. Features

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Residual Current Protective Devices

Breaking and protection devices

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Safety detection solutions

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

How can a charging station for electric vehicles be set up simply and safely?

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

HERZ-Thermal Actuators

ZS25 Screw Clamp Terminal Blocks Feed-through

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

PRO370D 65A Mbus MID DIN rail three phase four wire energy meter. User manual Version 1.03

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Unified requirements for systems with voltages above 1 kv up to 15 kv

Pluggable interface relays CR-P Pcb relays

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Thermistor motor protection

Plug and Socket Devices CES 63 A Series 8579

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Relés e Contatores de Estado Sólido SIRIUS

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Technical catalogue. Modular DIN rail components Installation contactors

Actuator-Sensor-Interface

Electrical auxiliaries 0 For i DPN (DPN), C60 and C120

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Series 8146/5-V37 and Series 8150/5-V37

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

Inductive sensor NI10-M18-Y1X-H1141

Circuit Breakers. Next Generation of Protection Capabilities

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Safety technique. Emergency stop module BO 5988 safemaster

A project to optimise quality and energy efficiency must include metering

RCA Remote Control ic60 Circuit Breakers Reference Manual

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

PSR The compact range Description

DS 600. A contact free flux gate based current measurement sensor 600A rms

Transcription:

87045 LIMOGES Cedex Telephone : (+33) 05 55 06 87 87 Fax : (+ 33) 05 55 06 88 88 R.C.C.B. s two-pole LEXIC 089 06/09/10/11/12/15/16/17/18/ 27/28/29/30/35, CONTENTS PAGES 1. Electrical and mechanical characteristics... 1 2. Installation... 4 3. Standards... 4 4. Environment... 4 5. Overall dimensions... 5 6. Marking... 5 7. Derating... 5 8. Association with upstream protection.. 6 9. Residual current tripping curves... 7 Symbol : Technology :. Electromagnetic residual current operating by sensitive relay Product range :. Two pole - 2 module (2 x 17,8 mm) Rated current :. 25 / 25 / 32 / 40 / 63 / 80 / 100 A Sensitivity :. 10 / 30 / 100 / 300 / 500 ma Type :. AC (residual sinusoidal alternating current). A (residual alternating current with a DC component). AC-S and A-S (selective). HPI (protected from unwanted trippings) Rated voltage / Frequency :. 230 V ~ - 50/60 Hz Insulation voltage :. Ui = 300 V Rated residual breaking capacity :. I m = 1000 A according to EN/IEC 61008-1 Rated making and breaking capacity : According to EN/IEC 61008-1 In = 16 / 25 / 32 / 40 A : Im = 500 A In = 63 A : Im = 630 A In = 80 A : Im = 800 A In = 100 A : Im = 1000 A Rated conditional short-circuit current :. Inc = 10 ka according to EN/IEC 61008-1 Rated conditional residual short-circuit current :. I c = 10 ka according to EN/IEC 61008-1 Ambient working temperature :. - 25 C / + 40 C Ambient storage temperature :. - 40 C / + 70 C Insulation against an impulse voltage :. Uimp = 6 kv Working positions : Dielectric strength :. 2000 V 50 Hz Insulation resistance :. 2 MΩ Pollution degree :. 2 1 / 8

090 53/56/57/58/ 59/62/63/74/75/76/77/82/86/87 Total dissipated power :. By device loaded at In I n 16 A 25 A 32 A 40 A 63 A 80 A 100 A 10 ma Type A and AC 30 ma Type A and AC 1.6W - - - - - - - 3 W 5 W 8W 8 W 13 W 20 W Others - 1.3W 2.1W 3.2W 8 W 13 W 20 W Protection against unwanted tripping :. 0.5µs/100 khz ring wave : 200A. 8/20 µs surge current: - type A AC : 250 A - type S, Hpi : 3000 A Heat and fire resistance :. Self extinguishing (glow wire test) : Base, Top and Test : 960 C Handle : 750 C Average weight per item : 0.23 kg Volume and quantity when packed : For all rated currents Volume Packaging 0.35 dm3 par 1 Mechanical and electrical endurance :. According to EN/IEC 61008-1 : - 20 000 operations without load - 10 000 operations with load (under In x Cos ϕ 0,9) - 1000 operations by test - 1000 operations by earth fault current Limit rated voltages for test operation triphase :. Rated voltage for operation : 230 V I n type U mini U maxi 10 ma All 110 V 250 V 30 ma All 110 V 250 V 100 ma All 130 V 250 V 300 ma A/AC/HPI 125 V 250 V 300 ma S 110 V 250 V 500 ma A/AC/HPI 130 V 250 V 500 ma S 120 V 250 V Protection degree :. Terminals protection against touching : IP20 (connected device). Front face protection against touching : IP40. Class II refered to metallic parts. Protection against shocks : IK04 Isolating distance (distance between contacts) :. Handle in open position (OFF) : - over à 4,5 mm Closing and opening forces by handle operation :. 2.3 kg at closing (every rated currents). 0.8 kg at opening (every rated currents) 2 / 8

6027 10/11/12/41, 928 30/31/38/ 39/41 Mains parts of R.C.C.B. : Terminals DIN rail clamp Mécanism lock Contacts Core subassembly Handle Test bottom Polarized relay with shield plate Terminals 3 / 8

2. INSTALLATION Fixing :. On symmetric rail EN 50.022 or DIN 35 Supply :. From the top or the bottom Connection :. Terminals with release type captive screw (feeder equipped preventing the insertion of a wire cable under the terminal, terminal half-opened or closed). Alignment and spacing of terminals allowing busbar connection with other products of the same range. Terminal depth : 14 mm. Terminal capacity : 60 mm². Max acceptable wire size : - 35 mm² flexible cables - 50 mm² rigid cables. Screw head : mixed, slotted and philips/pozidriv n 2 Tightening torque :. Minimum / Maximun : 1,2 Nm / 3,5 Nm. Recommended: 2,5 Nm Wire : Rigid cables Flexible cables Without ferrule 1 x 0,75 à 50 mm² ou 2 x 0,75 à 16 mm² 1 x 0,75 à 35 mm² ou 2 x 0,75 à 16 mm² Wiring accessories :. Supply busbar (réf. 049 44/45). Terminal screw covers (réf. 044 44). Lexiclic line distributor (réf. 048 70/74) + wires Tools required :. For terminals : - 5,5 mm or pozidriv n 2 screwdriver recommended. For fixing : - 5,5 mm recommended screwdriver Sealing :. Possible in open or closed position Locking :. Possible with support for padlock (ref. 044 42) With ferrule 1 x 0,75 à 25 mm² Marking :. Circuits marking on front (with label holder). With label design software (ref. 049 58). With electronic title printer (ref. 049 50) + ribbon (ref. 049 53/54). With plates of symbols (ref. 049 99) 2. INSTALLATION installation software:. XL PRO Auxiliaries list : Auxiliaries clipped on the left-hand side of the R.C.C.B. s Signalisation auxiliaries:. Auxiliary changeover switch (ref. 073 50) (0,5 module). Fault signalling changeover switch (ref. 073 51) (0,5 module). Auxiliary changeover switch, can be modified to a fault signalling switch (ref. 073 53) (0,5 module). Auxiliary changeover switch + fault signalling switch, can be modified to 2 auxiliary changeover switches (ref. 073 54) (1 module) Control auxiliaries :. Shunt trip (ref. 073 60/61) (1 module). Undervoltage release (ref. 073 65/66/68) (1 module). Motor driver control modules ( ref. 07370/71/73 ) ( 3 modules ) Possible combinations of auxiliaries and R.C.C.B. s : Maximum number of auxiliaries = 3.. Maximum number of signalling auxiliaries = 2 (only one auxiliary of ½ module width). Maximum number of control auxiliaries = 1. Control auxiliary must be positioned on the left-hand side of signalling auxiliaries in case of use of these two kinds of auxiliaries with the same R.C.C.B. Nota : Motor driver remote control module does not be associated with signalling auxiliaries 3. STANDARDS Compliance with standards :. NF EN 61008-1 / IEC 61008-1. EN/IEC 60 529 (IP). EN 50 102 (IK) 4. RESPECT OF ENVIRONMENT Compliance with European Union Rules :. Conformity with directive 2002/95/CE of 27/01/03 called «RoHS» that provides interdiction of dangerous material like lead, mercury, cadnium, hexavalent chrome, retarding of polybromobiphenyles (PBB) and polybromodiphnylethers (PBDE) bromed flame from july 2006 the 1st.. Conformity with directive 91/338/CEE of 18/06/91 and decree 94-647 of 27/07/94. Plastic material :. Enclosure plastic parts without halogen : - Base, Top and Test : PA 6 - Handle : PBT. Plastic parts marking according to ISO 11469 and ISO 1043 Packaging :. Packing design and manufacture according to decree 98-638 of 20/07/98 and directive 94/62/CE Technical Data Sheet : F00397EN/00 Updated : 01/06/06 Created : 02/06/06 4 / 8

5. OVERALL DIMENSIONS 6. MARKING Front face marking : by permanent pad printing. Mini working temperature Making and breaking capacity Legrand reference Diagram Type Sensitivity Rated voltage / current Short circuit withstand with use upstream 7. DERATING No derating for R.C.C.B. according to ambient temperature between -25 C et +40 C. 5 / 8

8. ASSOCIATION WITH UPSTREAM PROTECTION Protection against overloads :. R.C.C.B. must be protected (upstream or downstream) against overloads by a m.c.b. or a fuse at maximum with the same rate. 8. ASSOCIATION WITH UPSTREAM PROTECTION Protection against short-circuits :. R.C.C.B. must be protected (upstream) against short-circuits by a m.c.b. or a fuse. R.C.C.B. s short-circuit withstand complies with the hereunder tables. In case of single fault (230 / 400 V) TT, TN and IT network : DOWNSTREAM UPSTREAM MCB RCCB DNX DX (B/C) (B/C) DX-L DPX 125 16 A 4.5 ka 10 ka 20 ka 50 ka 25 ka 25 A 4.5 ka 10 ka 20 ka 50 ka 25 ka 32 A 4.5 ka 10 ka 20 ka 50 ka 25 ka 40 A 4.5 ka 10 ka 15 ka 50 ka 25 ka 63 A - 10 ka 12.5 ka 50 ka 25 ka 80 A - - 12.5 ka - 25 ka 100 A - - 12.5 ka - 25 ka DOWNSTREAM UPSTREAM RCCB gg FUSE Calibre 16 A 25 A 40 A 63 A 80 A 100 A 16 A 100 ka 100 ka 100 ka 50 ka 15 ka 10 ka 25 A - 100 ka 100 ka 50 ka 15 ka 10 ka 32 A - - 100 ka 50 ka 15 ka 10 ka 40 A - - 100 ka 50 ka 15 ka 10 ka 63 A - - - 50 ka 15 ka 10 ka 80 A - - - - 15 ka 10 ka 100 A - - - - - 10 ka Maximum value of short-circuit whistand of r.c.c.b. s function of associated protection in network 230V~/400V~ In case of double fault (1 pole at 400 V) IT network : DOWN- STREAM UPSTREAM MCB RCCB Breaking capacity Max DNX et DX 1P+N 1 mod DX 63 A 20 A 25 A 32 et 40 A 50 et 63 A 80 à 125 A DX-L DX-MA 50 ka DX-D 15 ka 32 A DX-D 15 ka 40 à 125 A DX-D 25 ka 10 à 40 A DX-MA 1.5 ka 3 ka 6 ka 5 ka 4 ka 3 ka 4 ka 6 ka 4 ka 3 ka 6 ka 4 ka 6 ka 2.5 à 40 A DX-MA 63 A 6 / 8

9. RESIDUAL CURRENT TRIPPING CURVES Curve of tripping time in terms of residual current TYPE AC 1 T (s) 0.5 10mA 0.1 0.05 0.01 10 0 10 1 10 2 10 3 ID (ma) 10 4 7 / 8

9. RESIDUAL CURRENT TRIPPING CURVES Curve of tripping time in terms of residual current TYPE A 1 T (s) 0.5 10mA 0.1 0.05 0.01 10 0 10 1 10 2 10 3 ID (ma) 10 4 8 / 8