Rittal IT Liquid Cooling Packages



Similar documents
Rittal White Paper 508: Economized Data Center Cooling Defining Methods & Implementation Practices By: Daniel Kennedy

Rittal Liquid Cooling Series

White Paper Rack climate control in data centres

Rittal White Paper 507: Understanding Data Center Cooling Energy Usage & Reduction Methods By: Daniel Kennedy

Elements of Energy Efficiency in Data Centre Cooling Architecture

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

EHDC. Cooling system for Data Center and server cabinets.

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Data Center Components Overview

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

NAISSUS THERMAL MANAGEMENT SOLUTIONS

GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.

How To Improve Energy Efficiency Through Raising Inlet Temperatures

Data Center Rack Level Cooling Utilizing Water-Cooled, Passive Rear Door Heat Exchangers (RDHx) as a Cost Effective Alternative to CRAH Air Cooling

Managing Data Centre Heat Issues

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Dealing with Thermal Issues in Data Center Universal Aisle Containment

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

- White Paper - Data Centre Cooling. Best Practice

APC APPLICATION NOTE #112

RiMatrix S Make easy.

The New Data Center Cooling Paradigm The Tiered Approach

CRAC Precision climate control units for data centres

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

News in Data Center Cooling

Rittal White Paper 305: Selecting Air Conditioners for Industrial Enclosures By: Judith Koetzsch Mark Corcoran, Editor

In Row Cooling Options for High Density IT Applications

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Benefits of Cold Aisle Containment During Cooling Failure

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

The Different Types of Air Conditioning Equipment for IT Environments

Data Center Equipment Power Trends

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Rittal the time has come...

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

APC APPLICATION NOTE #92

The Mission Critical Data Center Understand Complexity Improve Performance

IPSIP M series-m Modular Data Center

How To Use Rittal'S Rizone

European Code of Conduct for Data Centre. Presentation of the Awards 2013

Data Centre Testing and Commissioning

Blade Server & Data Room Cooling Specialists

Data Center 2020: Delivering high density in the Data Center; efficiently and reliably

Case Study: Guaranteed efficiency through standardised data centres

Unified Physical Infrastructure SM (UPI) Strategies for Smart Data Centers

National Grid Your Partner in Energy Solutions

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

HyPM Fuel Cell Power Modules

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

Environmental Data Center Management and Monitoring

The natural ombination

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

SERVER ROOM CABINET INSTALLATION CONCEPTS

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

White Paper. Data Center Containment Cooling Strategies. Abstract WHITE PAPER EC9001. Geist Updated August 2010

Technology Corporation

Standardised Data centres. Sales presentation

Reducing Data Center Energy Consumption

Thermal Monitoring Best Practices Benefits gained through proper deployment and utilizing sensors that work with evolving monitoring systems

Cabinet V800 V800 CABINETS

How To Run A Data Center Efficiently

Energy and Cost Analysis of Rittal Corporation Liquid Cooled Package

COMPARISON OF EFFICIENCY AND COSTS BETWEEN THREE CONCEPTS FOR DATA-CENTRE HEAT DISSIPATION

Access Server Rack Cabinet Compatibility Guide

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

Table of Contents. RimatriX5 IT Solutions from Rittal. Product Overview Section 1... Pages Enclosures Section 2...

Cabinets 101: Configuring A Network Or Server Cabinet

Introducing Computational Fluid Dynamics Virtual Facility 6SigmaDC

How To Build A T7 Rack For Information Technology

Anixter ipassured SM for Data Centres. Products. Technology. Services. Delivered Globally.

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

Choosing Close-Coupled IT Cooling Solutions

Eaton 93PM UPS Efficient. Scalable. Innovative.

JAWAHARLAL NEHRU UNIVERSITY

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE

Benefits of. Air Flow Management. Data Center

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

How to Build a Data Centre Cooling Budget. Ian Cathcart

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000

Eaton 93PM UPS Where aesthetics meet intelligence.

Alcatel-Lucent Modular Cooling Solution

Element D Services Heating, Ventilating, and Air Conditioning

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

An Introduction to Cold Aisle Containment Systems in the Data Centre

Alan Matzka, P.E., Senior Mechanical Engineer Bradford Consulting Engineers

Technical Systems. Helen Bedford

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

State of the Art Energy Efficient Data Centre Air Conditioning

DataCenter 2020: hot aisle and cold aisle containment efficiencies reveal no significant differences

Transcription:

Rittal IT Liquid Cooling Packages Higher Efficiency & Performance Optimized for Today s Data Centers R

High Efficiency. High Performance. High Density. Rittal leads the industry in developing high density cooling solutions that maximize performance while reducing energy consumption, utility costs, and negative impacts on the environment. Rittal s scalable Liquid Cooling Packages (LCPs) can handle high heat densities (up to 44 kw per rack) and adapt to changing requirements as quickly as needed all while reducing energy consumption and costs by up to 30-45%. At their core, Rittal LCPs are air-to-water heat exchangers that operate simply with connections to facility chiller systems that, in many cases, already exist on-site (Rittal can provide chiller systems if necessary). Heat energy from installed IT equipment is absorbed and removed from the rack, at the rack level, by water (which has a 3,500 times greater thermal capacity than air), and then fan modules circulate the cooled air created by this exchange through the equipment. Once the cycle is complete, the process is repeated. Rittal LCPs are available in a variety of different styles that are intended to provide users with a tremendous amount of flexibility that allows for creative, efficient, and effective solutions that deliver unmatched returns for investment (many installations pay for themselves within two years of deployment via saved utility costs). Rittal Liquid Cooling Packages can be used in open or closed loop and hybrid configurations, with or without hot aisles and containment systems, and can either be designed into a new deployment or retrofitted to expand the efficiency of existing installations. 2

Rittal LCP: Quick Facts Remove up to 44 kw of heat from the rack enclosure. Reduce energy consumption by up to 30-45% better for the environment and your bottom line. Flexible and scalable suitable for any size installation and can be easily retrofitted. Pay as you grow. Allow for maximum cooling economization can effectively utilize higher temperature inlet water (59 F or warmer) than competitor offerings. Rittal vs Competition Can handle higher density loads more effectively. More efficient. Unmatched ROI Thanks to utility savings, many installations pay for themselves within 2 years of deployment. Ability to use substantially warmer inlet water provides greater opportunities for economizing or Free Cooling. IT Liquid Cooling Packages Benefits Overview About Free Cooling Free cooling refers to the hours of operation when a data center can be cooled effectively without using components of a facility s cooling system that consume large amounts of energy (usually the chiller compressor). When employing liquid cooling solutions, the closer the temperature of acceptable inlet water gets to that of the ambient air, while still removing the necessary heat from rack enclosures, the higher the potential for extended periods free cooling. About Closed & Open Loop Configurations Data centers are typically organized in closed or open loop cooling configurations. In some cases, hybrid configurations utilizing both strategies, such as those made possible by Rittal s specialized LCP Hybrid with Perforated Front Door & Rear Aisle Containment, can be used. Generally speaking, closed loop systems are completely self-contained and consist of enclosures with solid external surfaces and integrated cooling units. This approach allows higher density loads to be handled, and for temperature-neutral expansion of the data center. In open loop configurations, rack enclosures with perforated front and rear doors are often employed, and the cooling solutions require some degree of interaction with the ambient data center environment in order to function properly. Available Models LCP+ (Closed Loop) LCP T3+ (Closed Loop) LCP Inline (Open Loop) LCP Extend (Open Loop) All LCP units available in either RAL 7035 light gray or in sand texture black. LCP Hybrid systems w/ Perforated Front Door & Rear Aisle Containment also available upon request. Shown at left LCP Inline 3

Closed Loop - LCP+ The LCP+ is ideal for high density data center environments, as well as the natural environment effectively handling loads of up to 44 kw while reducing energy consumption by up to 45%. LCP+ Part Numbers RAL 7035 light gray 3301.480 Sand texture black 3301.485 *See specifications below. Typical: 30 kw System Capacity Maximum: 44 kw LCP+ can support multiple cabinets with a variety of heat loads. Capacity is based on the following parameters: flow rate, ΔP, ΔT, Server ΔT, and desired air temperature. Input specifications 208 V, single-phase, 3-wire, 60 Hz AC input nominal voltage Frequency 50/60 Hz Chilled water supply temperature 45ºF to 70ºF (Typical Range) Maximum water flow rate 26 gpm Physical characteristics Dimensions (HxWxD): 2000 x 300 x1200 mm 80 x 12 x 48 inches Weight 506 lb / 230 kg Additional parameters Airflow volume 2800 cfm Cold air supply temperature 50ºF to 85ºF (Typical Range) Standard Fans: 10.4A, 2.4 kw Fans EC fan option: 1.2 kw Water supply pressure 24.5 to 116 PSI System noise 64 dba (free field on reflective floor) 1-inch external thread connection; bottom or rear connection points for Water system connections both chilled water supply and warm water lines. Purified cooling water. No lime scale or loose debris. Low hardness Water supply quality and low conductivity. Software Connectivity Compatible with the following operating systems: Microsoft Windows 2000 (Server, Advanced Server, Professional) Windows XP Home, Windows XP Professional, Windows 2003 Server (Web, Small Software compatibility Business), Windows 2003 Server (Standard, Enterprise), Windows 2003 Server R2 (Standard Enterprise), Windows Vista (Ultimate, Home Premium, Business), Windows XP on 64-bit architecture. Optional data center, Windows-based client/server software package Support for multiple systems in the data center (RiWatchIT) that provides real-time monitoring of critical conditions for the entire enterprise. Certifications Certifications and Approvals UL, CUL, CE, TÜV Country of Origin Manufactured in USA 4

Closed Loop - LCP T3+ The LCP T3+ provides a level of redundancy in high density cooling by combining the functionality of two independent LCP+ systems in a single unit to ensure availability while conserving valuable floor space. LCP T3+ To order in either RAL 7035 light gray or sand texture black, please contact your Rittal representative or call 1-800-477-4000 to inquire. *See specifications below. Typical: 20 kw System Capacity Maximum: 30 kw LCP+ can support multiple cabinets with a variety of heat loads. Capacity is based on the following parameters: flow rate, ΔP, ΔT, Server ΔT, and desired air temperature. Input specifications 208 V, single-phase, 3-wire, 60 Hz AC input nominal voltage Frequency 50/60 Hz Chilled water supply temperature 59ºF to 70ºF (Typical Range) Maximum water flow rate 26 gpm Physical characteristics Dimensions (HxWxD): 2000 x 300 x1200 mm 80 or 87 x 12 x 48 inches Weight 440 lb at 80 or 475 lb at 88 / 200 kg or 230 kg Additional parameters Airflow volume 2800 cfm Cold air supply temperature 59ºF to 85ºF (Typical Range) Standard Fans: 10.2A, 2.3 kw Fans EC fan option: 1.2 kw Water supply pressure 24.5 to 116 PSI System noise 64 dba (free field on reflective floor) 1-inch external thread connection; bottom or rear connection points for Water system connections both chilled water supply and warm water lines. Purified cooling water. No lime scale or loose debris. Low hardness and Water supply quality low conductivity. Software Connectivity Compatible with the following operating systems: Microsoft Windows 2000 (Server, Advanced Server, Professional) Windows XP Home, Windows XP Professional, Windows 2003 Server (Web, Small Business), Software compatibility Windows 2003 Server (Standard, Enterprise), Windows 2003 Server R2 (Standard Enterprise), Windows Vista (Ultimate, Home Premium, Business), Windows XP on 64-bit architecture. Optional data center, Windows-based client/server software package Support for multiple systems in the data center (RiWatchIT) that provides real-time monitoring of critical conditions for the entire enterprise. Certifications Certifications and Approvals CE, TÜV Country of Origin Manufactured in Germany 5

Open Loop - LCP Inline The LCP Inline comes equipped with variable speed fans and a high efficiency heat exchanger coil to remove heat from the hot aisle and provide cool air to the cold aisle in a way that reduces energy consumption and utility costs. LCP Inline Part Numbers RAL 7035 light gray 3301.470 Sand texture black 3301.475 *See specifications below. Typical: 30 kw System Capacity Maximum: 44 kw LCP Inline can support multiple cabinets with a variety of heat loads. Capacity is based on the following parameters: flow rate, ΔP, ΔT, Server ΔT, and desired air temperature. Input specifications 208 V, single-phase, 3-wire, 60 Hz AC input nominal voltage Frequency 50/60 Hz Chilled water supply temperature 45ºF to 70ºF (Typical Range) Maximum water flow rate 26 gpm Physical characteristics Dimensions (HxWxD): 2000 x 300 x1050 mm 80 x 12 x 42 or 48 inches Weight 475 lb - 42 or 506 lb - 48 215 kg / 230 kg Additional parameters Airflow volume 2800 cfm Cold air supply temperature 50ºF to 85ºF (Typical Range) Standard Fans: 10.4A, 2.4 kw Fans EC fan option: 1.2 kw Water supply pressure 24.5 to 116 PSI System noise 70 dba (free field on reflective floor) 1-inch NPT external thread connection; bottom or rear connection Water system connections points for both chilled water supply and warm water lines. Purified cooling water. No lime scale or loose debris. Low hardness Water supply quality and low conductivity. Software Connectivity Compatible with the following operating systems: Microsoft Windows 2000 (Server, Advanced Server, Professional) Windows XP Home, Windows XP Professional, Windows 2003 Server (Web, Small Software compatibility Business), Windows 2003 Server (Standard, Enterprise), Windows 2003 Server R2 (Standard Enterprise), Windows Vista (Ultimate, Home Premium, Business), Windows XP on 64-bit architecture. Optional data center, Windows-based client/server software package Support for multiple systems in the data center (RiWatchIT) that provides real-time monitoring of critical conditions for the entire enterprise. Certifications Certifications and Approvals UL, CUL, CE, TÜV Country of Origin Manufactured in USA 6

Open Loop - LCP Extend The LCP Extend is perfect for retrofitting existing deployments to easily eliminate hot spots, conserve space, and enhance efficiency & performance by simply mounting the unit on the rear of an enclosure (in place of the door). LCP Extend Part Numbers RAL 7035 light gray 3301.490 Sand texture black 9960.627 *See specifications below. Typical: 10 kw System Capacity Maximum: 15 kw LCP Extend can support multiple cabinets with a variety of heat loads. Capacity is based on the following parameters: flow rate, ΔP, ΔT, Server ΔT, and desired air temperature. Input specifications 208 V, single-phase, 3-wire, 60 Hz AC input nominal voltage Frequency 50/60 Hz Chilled water supply temperature 59ºF to 70ºF (Typical Range) Maximum water flow rate 12 gpm Physical characteristics Dimensions (HxWxD): 2000 x 300 x1200 mm 80 x 24 x 6 inches Weight 286 lb /130 kg Additional parameters Airflow volume 1780 cfm Cold air supply temperature 59ºF to 85ºF (Typical Range) Standard Fans: 5.6A, 1.2 kw Fans EC fan option: 1.2 kw Water supply pressure 24.5 to 116 PSI System noise 79 dba (free field on reflective floor) 3/4-inch external thread connection; bottom or rear connection points Water system connections for both chilled water supply and warm water lines. Purified cooling water. No lime scale or loose debris. Low hardness and Water supply quality low conductivity. Software Connectivity Compatible with the following operating systems: Microsoft Windows 2000 (Server, Advanced Server, Professional) Windows XP Home, Windows XP Professional, Windows 2003 Server (Web, Small Business), Software compatibility Windows 2003 Server (Standard, Enterprise), Windows 2003 Server R2 (Standard Enterprise), Windows Vista (Ultimate, Home Premium, Business), Windows XP on 64-bit architecture. Optional data center, Windows-based client/server software package Support for multiple systems in the data center (RiWatchIT) that provides real-time monitoring of critical conditions for the entire enterprise. Certifications Certifications and Approvals UL, CUL, CE, TÜV Country of Origin Manufactured in Germany 7

Rittal Your Choice for Comprehensive Cooling & Physical IT Infrastructure System Solutions Rittal has everything you need to create efficient and reliable physical IT infrastructure systems that can expand performance, ensure availability, and help you to save money. We offer a wide range of rack enclosures, cooling, power management, security and monitoring products that are proven every day in data centers around the world from small and medium deployments all the way to large, enterprise-level installations. Utilizing a modular architecture, we excel at delivering flexible, scalable solutions tailored to the specific needs of our customers. Whether you re looking for a simple rack enclosure, efficiency enhancements like aisle containment, or a complete infrastructure system to support high density loads, we have the products, service, and expertise to get your operations optimized and moving in the right direction. Find out how Rittal can help you create the ideal solution for your needs. You can contact Rittal: By phone: 1-800-477-4000 By visiting our website: www.rittal-corp.com By email: rittal@rittal-corp.com By Fax: 1-800-477-4003 Related Rittal Literature Please visit www.rittal-corp.com/literature to view in-depth product information and informative white papers that can help you get the most out of your applications. RimatriX5 IT Solutions Catalog Everything for today s physical IT infrastructure including rack enclosures, high density cooling, power, security and monitoring products. CMC-TC Wireless Sensor Network Security & monitoring for even the most complex IT infrastructures. Rittal White Paper 506: Cold Aisle Containment for Improved Data Center Cooling Efficiency This paper documents the testing of a cold aisle containment system in a live data center. Rittal White Paper 507: Understanding Data Center Cooling Energy Usage & Reduction Methods This white paper provides a clear understanding of the cooling and heat removal infrastructure requirements for high density data centers. The Rittal Corporation is the U.S. subsidiary of Rittal GmbH & Co. KG and manufactures the world s leading industrial and IT enclosures, racks and accessories, including climate control, power management and electronic packaging systems for industrial, data center, outdoor and hybrid applications. For more information about Rittal Corporation and its products, please visit www.rittal-corp.com or call 1-800-477-4000. 1/10 US181 Rittal Corporation 1 Rittal Place Urbana, Ohio 43078 USA Phone: 937-399-0500 Fax: 937-390-5599 Toll-free: 800-477-4000 Email: rittal@rittal-corp.com Website: www.rittal-corp.com Rittal Systems Ltd. 7320 Pacific Circle Mississauga, Ontario L5T 1V1 Canada Phone: 905-795-0777 Fax: 905-795-9548 Toll-free: 800-399-0748 R